H3CA-8 AC100/110/120

Solid-state Timer

Image

48 x 48 x 89 mm, 100/110/120 VAC, Time range 0.1 s to 9990 h (7 range), Output Time-limit contact: DPDT, 8-pin round socket

Rated supply voltage 100 VAC 50/60 Hz
110 VAC 50/60 Hz
120 VAC 50/60 Hz
Time range 0.1s to 9990h
Input method No-voltage input
Output modes A (Power ON delay)
Control output Time-limit contact: DPDT
Display method LCD
External connection method 8-pin round socket

Item list of H3CA

  • Ratings/Performance
Rated supply voltage100 VAC 50/60 Hz
110 VAC 50/60 Hz
120 VAC 50/60 Hz
Operating voltage range85% to 110% of rated supply voltage
Power consumption10VA / 1W
Time ranges(Number of ranges)7
Time ranges0.1 s to 99.9 s / 1 s to 999 s / 0.1 min to 99.9 min / 1 min to 999 min / 0.1 h to 99.9 h / 1 h to 999 h / 10 h to 9990 h
Select methodThumbwheel Switch
Input methodNo-voltage input
Output modesA (Power ON delay)
Control output (Contact output)Type: Time-limit contact: DPDT
Switching capacities (Resistive load): 3 A at 250 VAC
Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Reset systemSelf-reset
Power resetReset time: 0.1 s max.
Display methodLCD
Digit3 digit
Ambient temperatureOperating: -10 to 55 ℃
Ambient humidityOperating: 35 to 85%RH
Accuracy of operating time±0.3% ±0.05 s (The values are based on the set value.)
Setting error±0.5% ±0.05 s (The values are based on the set value.)
Influence of voltage±0.3% ±0.05 s (The values are based on the set value.)
Influence of temperature±0.3% ±0.05 s (The values are based on the set value.)
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strengthBetween current carrying metal parts and non-current carrying metal parts: 2000
Between control output terminals and operating circuit: 2000
Between non-continuous contacts: 1000
Impulse withstand voltage5 kV
Vibration resistance (Destruction)10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour
Vibration resistance (Malfunction)10 to 55 Hz, 0.5-mm single amplitude each in 3 directions for 10 min
Shock resistance (Destruction)1,000 m/s**2, 3 times each in 6 directions
Shock resistance (Malfunction)100 m/s**2, 3 times each in 6 directions
Mechanical life10 million operations min. (under no load at 1,800 operations/h)
Electrical life100,000 operations min. (3 A at 250 VAC resistive load at 1800 operations/h)
Degree of protectionPanel surface: IP40
Mounting methodFlush mounting / Surface mounting
External connection method8-pin round socket
Accessory (sold separately)Y92A-48D: Soft Cover
Y92A-48B: Hard Cover
Y92F-30: Flush mounting adapter
Y92F-70: Flush mounting adapter
Y92F-71: Flush mounting adapter
Weight約110g
  • Dimensions

  • Block diagram

  • Electrical life

Series

Solid-state Timer

H3CA