Solid-state Timer
Rated supply voltage |
100 VAC 50/60 Hz 110 VAC 50/60 Hz 120 VAC 50/60 Hz |
---|---|
Time range |
0.1s to 9990h |
Input method |
No-voltage input |
Output modes |
A (Power ON delay) |
Control output |
Time-limit contact: DPDT |
Display method |
LCD |
External connection method |
8-pin round socket |
As of August 8, 2016
Rated supply voltage | 100 VAC 50/60 Hz 110 VAC 50/60 Hz 120 VAC 50/60 Hz |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption | 10VA / 1W |
Time ranges(Number of ranges) | 7 |
Time ranges | 0.1 s to 99.9 s / 1 s to 999 s / 0.1 min to 99.9 min / 1 min to 999 min / 0.1 h to 99.9 h / 1 h to 999 h / 10 h to 9990 h |
Select method | Thumbwheel Switch |
Input method | No-voltage input |
Output modes | A (Power ON delay) |
Control output (Contact output) | Type: Time-limit contact: DPDT Switching capacities (Resistive load): 3 A at 250 VAC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
Reset system | Self-reset |
Power reset | Reset time: 0.1 s max. |
Display method | LCD |
Digit | 3 digit |
Ambient temperature | Operating: -10 to 55 ℃ |
Ambient humidity | Operating: 35 to 85%RH |
Accuracy of operating time | ±0.3% ±0.05 s (The values are based on the set value.) |
Setting error | ±0.5% ±0.05 s (The values are based on the set value.) |
Influence of voltage | ±0.3% ±0.05 s (The values are based on the set value.) |
Influence of temperature | ±0.3% ±0.05 s (The values are based on the set value.) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2000 Between control output terminals and operating circuit: 2000 Between non-continuous contacts: 1000 |
Impulse withstand voltage | 5 kV |
Vibration resistance (Destruction) | 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour |
Vibration resistance (Malfunction) | 10 to 55 Hz, 0.5-mm single amplitude each in 3 directions for 10 min |
Shock resistance (Destruction) | 1,000 m/s**2, 3 times each in 6 directions |
Shock resistance (Malfunction) | 100 m/s**2, 3 times each in 6 directions |
Mechanical life | 10 million operations min. (under no load at 1,800 operations/h) |
Electrical life | 100,000 operations min. (3 A at 250 VAC resistive load at 1800 operations/h) |
Degree of protection | Panel surface: IP40 |
Mounting method | Flush mounting / Surface mounting |
External connection method | 8-pin round socket |
Accessory (sold separately) | Y92A-48D: Soft Cover Y92A-48B: Hard Cover Y92F-30: Flush mounting adapter Y92F-70: Flush mounting adapter Y92F-71: Flush mounting adapter |
Weight | 約110g |
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
As of August 8, 2016
about this Product