Electronics Finder chervon right Manufacturers chervon right A chervon right ANDERSON POWER PRODUCTS chervon right 2002G3KIT
About product Specifications Datasheet FAQ

ANDERSON POWER PRODUCTS 2002G3KIT

Image of ANDERSON POWER PRODUCTS 2002G3KIT

Description

Conn Power RCP 3 POS Crimp ST Panel Mount 3 Terminal 1 Port
2002G3KIT

Part Number

2002G3KIT

Price

Request Quote

Manufacturer

ANDERSON POWER PRODUCTS

Lead Time

Request Quote

Category

Connectors »  Connector Power

Specifications

Manufacturer

Anderson Power Products

Manufacturers Part #

2002G3KIT

Lead Time

6 Week Lead Time

Sub-Category

Power Connectors

Factory Pack Quantity

1

Datasheet

pdf file

DS-SDG.pdf

1686 KiB

Extracted Text

Safe Connections for Higher Voltage Power Distribution Systems ® Anderson Power Products has lead the connector industry First Mate, Last Break in development of DC power connection solutions since the Ground Contact ® ® introduction of the SB electrical connector in 1953. Saf-D-Grid • Provides the safety of an ® Ultra Short earthing path before builds on the proven contact technology used in SB and Receptacle ® engagement of the power Powerpole connectors by offering features required in 380-400 contacts. VDC power distribution systems. ® ® Integral Latch APP introduced the Saf-D-Grid connector system in January • Connectors cannot be 2009 as a safe appliance power connector for server, telecom- accidentally unmated, munication, and other devices up to 600 VDC. preventing unwanted power loss to critical ® ® The APP Saf-D-Grid plug and receptacle provide for the equipment. T-Latch direct connection of DC electronic devices to a DC micro-grid Straight Plug powered by renewable energy or high efficiency DC sources. Hot Plug Rated The connector meets international safety requirements for • The connectors are rated for current interruption for both hazardous, low voltage applications including UL 950 and IEC electronic (capacitive) and electrical (resistive) loads. ® 60950. The Saf-D-Grid is size compatible with the IEC 320 C13 and C14 AC connection system. It is the only connector Touch Safe / Shock Protection system so sized that is UL rated for disconnect of a 400 VDC, • Minimizes the risk of personal contact with a hazardous voltage. 20 amp load. Passes UL & IEC finger probe (plug & receptacle) and 3mm probe tests (receptacle). ® Saf-D-Grid also enables greater power density by allowing up to 40A and 600V DC or AC within the same space of the IEC Arcing Protection 320 C13 & C14 system that is limited to 10A and 250 VAC. • Housings contain the arc if connectors are mated or unmated ® while under load minimizing risk to personnel. This allows the use of Saf-D-Grid in AC systems that require more power by increasing the wattage capability within the existing connector space. | SPECIFICATIONS | Mechanical Electrical Protection Contact Retention (lbf) 20 IEC 60529 IP20 Voltage (AC/DC) (N) 89 • UL 1977 / CSA 22.2 600 Plug Latch Retention (lbf) 20 • IEC 400 (N) 89 Current Rating (Amperes) 40 Panel Latch Retention (lbf) 60 Wire Range (AWG) #12 to #18 (N) 267 (mm²) 2.5 to 0.75 Durability 5,000 cycles - no load Hot Plug Rated Receptacle Max Wire OD (in) 0.22 • 250 cycles 400V @ 440A in-rush (mm) 5.6 • 250 cycles (UL) 400V @ 20A load Creep & Clearance per UL & IEC 60950 Dielectric Withstanding Voltage 3,300 Between live parts of different polarity, Operating Temperature (°C) -20° to 80° earthing circuit and the mating surface. (°F) -4° to 176° • Short and Flush Receptacle with Crimp Contacts 8.0 mm Fault Current Withstand UL 467 14 AWG, 300A, 4 Sec. • Ultra Short Receptacle, Short and Flush Receptacle with Solder or PCB Contacts 7.0 mm Materials (RoHS Compliant) A Maximum PCB Thickness (in) 0.093 Housings (mm) 2.4 • 2006G1 Series Receptacles Hi Temp Nylon + 30% GF, UL94 V-0, Halogen Free B • All other Receptacles & Plugs Polycarbonate UL94 V-0 Mechanical Shock IEC 60512-4-6C 50g’s Springs Stainless Steel B Contacts Copper, Silver Plate Vibration, High Frequency IEC 60512-4-6d 20g’s Cable / Strain Relief Thermoplastic UL94 V-2 A Applicable only to receptacles intended for termination to PCB B Tested with straight plug and flush mount receptacle with #14 AWG wire and 2003G1 contacts. - 2 - | TEMPERATURE CHARTS | Saf-D-Grid® Saf-D-Grid ® Derating vs. Ambient Temperature Temperature Rise at Constant Current 85 60 75 50 65 40 55 30 45 20 35 10 25 0 0 5 10 15 20 25 30 35 40 45 50 0 5 10 15 20 25 30 35 40 45 Amperes Applied Amperes Applied 12 AWG 14 AWG 12 AWG 14 AWG 16 AWG 18 AWG 16 AWG 18 AWG | UL 1977 & IEC 61984 RATINGS | | UL 817 RATINGS | Rated Rated Disconnect Current Receptacle Conditions Agency Current Voltage Connector Type / Only Interrupt Series Wire Size of Use Rating Amp AC / DC Cable Type Wire Size (600V Max) (400V Max) Disconnect CNR 12 600 Straight Plug / Only UL 1977 18 600 14 AWG 18 18 Flush 2002 18 AWG plug SOOW 600V Current & Short 2005 & receptacle UL 1977 12 400 Interrupt 18 AWG 10 10 Straight Plug / Disconnect CNR 14 600 ST 600V Flush 2002 16 AWG 13 13 16 AWG plug Only UL 1977 18 600 & Short 2005 & receptacle Current 400 14 AWG 18 18 UL 1977 14 Interrupt Straight Plug / Disconnect 14 AWG 18 181 1 1.5 mm² plug SJT 300V Flush 2002 Only 3 IEC 61984 14 400 & Short 2005 & receptacle Current IEC C20 Plug / Interrupt 14 AWG 16 N/A 2 SJT 250V Disconnect 3 IEC 61984 25 400 Only 14 AWG plug Flush 2002 18 AWG 10 10 Right Angle Plug / & Short 2005 & receptacle Current UL 1977, CNR 20 400 16 AWG 13 13 Interrupt 3 ST 600V IEC 61984 Disconnect CNR 30 600 14 AWG 18 18 Flush 2002 Only 12 AWG plug UL 1977 40 600 & Short 2005 18 AWG 10 10 & receptacle Current T-Latch Plug / 30 400 UL 1977 Interrupt ST 600V 16 AWG 13 13 CNR 13 600 Disconnect IEC 61984 13 400 14 AWG 18 18 Only Ultra Short 18 AWG plug UL 1977 21 600 2006G Note: Voltage limited by wire insulation rating 1 & receptacle Current IEC 61984 13 400 Note: Voltage limited by the IEC connector on the cord set 2 Interrupt UL 1977, CNR 12 400 Disconnect Ultra Short 1.5 mm² plug Only | CCC RATINGS | - Pending IEC 61984 14 400 2006G & receptacle Current Interrupt Rated Rated CNR 25 600 Receptacle Wire Size Conditions Current Voltage Disconnect IEC 61984 25 400 Series Amp AC / DC Only AWG of Use 14 AWG plug Ultra Short UL 1977 35 600 2006G & receptacle Ultra Short 2.5 mm² plug Current Current UL 1977, CNR 20 400 20 400 Interrupt 2006G & receptacle Interrupt IEC 61984 Note: No IEC 61984 approvals for 2002N, 2002V, 2005N & 2005V series receptacles. 3 • UL1977 ratings are for recognized components under UL1977 file# E26226. Ratings may vary once the final listing category is considered. Do not exceed maximum operating temperature of connector or wire insulation. Ratings are based on an ambient temperature of 25˚C. • CNR - indicates investigation to Canadian National Standards, C22.2 No. 182.3. • UL817 recognized or listed cord sets under UL file number E 343569. • IEC 61984 certification by TUV certification number R 7212289. • “Disconnect Only” indicates the devices are not for interrupting current. • “Current Interrupt” indicates the devices have been investigated for the interruption of current. • APP assembly tooling is required for UL, CSA & other safety agency compliance. Use of unapproved tooling will void connector warranty. • CCC Certification to: GB/T11918-2001: Part 1 (idt IEC 60309-1:1999) & GB/T11919-2001: Part 2 (idt IEC 60309-2:1999) • CCC Certification is only required for connectors which are built to CCC recognized dimensional & performance standards. Saf-D-Grid was voluntarily submitted to CCC under performance only aspects of relevant standards. - 3 - Temperature (°C) Temperature (°C) | PANEL MOUNT RECEPTACLES | - For Crimp Termination to Wire Receptacle Housings Only Housing Style & Non-Bulk Std. Bulk Std. Short Receptacle Panel Thickness - Part Numbers - Pack - Part Numbers - Pack Mid-flange snap-in panel mount Short Depth design shortens space required 0.8mm 2005G1 1 2005G1-BK 100 inside the panel. For use with crimp wire contacts. 1.0mm 2005G3 1 2005G3-BK 100 1.6mm 2005G4 1 2005G4-BK 100 Flush Mount 0.8mm 2002G1 1 2002G1-BK 100 1.0mm 2002G3 1 2002G3-BK 100 Flush Mount Receptacle 1.2mm 2002G2 1 2002G2-BK 100 1.6mm 2002G4 1 2002G4-BK 100 Flush snap-in panel mount design is 2.0mm 2002G5 1 2002G5-BK 100 compatible with 2.5mm 2002G6 1 2002G6-BK 100 crimp wire contacts. Contacts - #12 to 18 AWG Compatible Loose Piece Std. Reeled Std. Receptacles - Part Numbers - Pack - Part Numbers - Pack Flush Mount 2003G1-LPBK 1 2003G1 2,500 Crimp Contact | TOOLING | Tooling Available Directly from Anderson Power Products (All Customers) Automated Tooling Contact Hand Tool Press Applicator Part Number Description 115V = TE0101 ₋ 2003G1 Receptacle Contact, Reeled TD0104 230V = TE0102 ₋ ₋ 2003G1-LPBK Receptacle Contact, Loose Piece 1309G9 Hand Tool Additional Tooling Available Directly from ATS (North American Customers Only) Automated Tooling Contact Press Air Feed Applicator Part Number Description 2003G1 Receptacle Contact, Reeled 354500-1 354578-1 1852859-3 Applicator Press • Contact ATS Directly to Purchase or Lease Tooling P.O. Box 6780, Harrisburg, PA 17112 USA T: 877-671-2955 F: 717-810-2862 www.applicationtooling.com NOTE: Tooling recommended by APP is required for UL, CSA & other safety agency compliance. Use of unapproved tooling will void connector warranty. NOTE: Shading Indicates Build to Order - 4 - | PANEL MOUNT RECEPTACLES | - For Solder Termination to Wire Receptacle Kits (Housing & Contacts) Termination Panel Non-Bulk Std. Bulk Std. Ultra Short Receptacle Housing Type Thickness - Part Numbers - Pack - Part Numbers - Pack Mid-flange snap in panel mount design for direct solder wire Flush Mount Wire, Crimp* 0.8mm 2002G1KIT 1 N/A N/A termination uses minimal space Flush Mount Wire, Crimp* 1.0mm 2002G3KIT 1 N/A N/A inside the panel. Halogen free. Flush Mount Wire, Crimp* 1.2mm 2002G2KIT 1 N/A N/A Flush Mount Wire, Crimp* 1.6mm 2002G4KIT 1 N/A N/A Flush Mount Wire, Solder 0.8mm 2002N1 1 2002N1-BK 100 Flush Mount Wire, Solder 1.0mm 2002N3 1 2002N3-BK 100 Flush Mount Wire, Solder 1.2mm 2002N2 1 2002N2-BK 100 Short Receptacle Flush Mount Wire, Solder 1.6mm 2002N4 1 2002N4-BK 100 Short receptacle housing fully Short Depth Wire, Crimp* 0.8mm 2005G1KIT 1 N/A N/A assembled with contacts for Short Depth Wire, Crimp* 1.0mm 2005G3KIT 1 N/A N/A direct solder wire termination. Short Depth Wire, Crimp* 1.6mm 2005G4KIT 1 N/A N/A Short Depth Wire, Solder 0.8mm 2005N1 1 2005N1-BK 100 Short Depth Wire, Solder 1.0mm 2005N3 1 2005N3-BK 100 Short Depth Wire, Solder 1.6mm 2005N4 1 2005N4-BK 100 Ultra Short Depth Wire, Solder 0.8mm 2006G1 1 2006G1-BK 100 Ultra Short Depth Wire, Solder 1.0mm 2006G3 1 2006G3-BK 100 Flush Mount Receptacle Ultra Short Depth Wire, Solder 1.2mm 2006G2 1 2006G2-BK 100 Standard receptacle housing fully Ultra Short Depth Wire, Solder 1.6mm 2006G4 1 2006G4-BK 100 assembled with contacts for direct Ultra Short Depth Wire, Solder 2.0mm 2006G5 1 2006G5-BK 100 solder wire termination. Ultra Short Depth Wire, Solder 2.5mm 2006G6 1 2006G6-BK 100 *Includes Contact Part Number 2003G1 Pre-Terminated to 12 inches of #16 AWG, 600V Wire Receptacle Housings Only Contacts - #14 to 18 AWG Compatible Loose Piece Std. Reeled Std. Housing Style & Non-Bulk Std. Bulk Std. Receptacles - Part Numbers - Pack - Part Numbers - Pack Panel Thickness - Part Numbers - Pack - Part Numbers - Pack Ultra Short 2016G1-LPBK 1 - - Ultra Short Depth 0.8mm 2006G1-NC 1 2006G1-NC-BK 100 NOTE: 1.0mm 2006G3-NC 1 2006G3-NC-BK 100 • Ultra short contacts are to be used with ultra short depth housings 1.2mm 2006G2-NC 1 2006G2-NC-BK 100 only, for soldering to stranded copper wire. 1.6mm 2006G4-NC 1 2006G4-NC-BK 100 2.0mm 2006G5-NC 1 2006G5-NC-BK 100 2.5mm 2006G6-NC 1 2006G6-NC-BK 100 Ultra Short Solder Contact | PANEL MOUNT RECEPTACLES | - For Solder Termination to PCB Receptacle Kits (Housing & Contacts) Termination Panel Non-Bulk Std. Bulk Std. Short Receptacle Housing Type Thickness - Part Numbers - Pack - Part Numbers - Pack Short receptacle housing fully assembled with PCB contacts Flush Mount PCB, Solder 0.8mm 2002V1 1 2002V1-BK 100 for 0.062 (1.57 mm) to 0.093 Flush Mount PCB, Solder 1.0mm 2002V3 1 2002V3-BK 100 (2.36 mm) inch boards. Flush Mount PCB, Solder 1.2mm 2002V2 1 2002V2-BK 100 Flush Mount PCB, Solder 1.6mm 2002V4 1 2002V4-BK 100 Short Depth PCB, Solder 0.8mm 2005V1 1 2005V1-BK 100 Short Depth PCB, Solder 1.0mm 2005V3 1 2005V3-BK 100 Short Depth PCB, Solder 1.6mm 2005V4 1 2005V4-BK 100 Flush Mount Receptacle Standard receptacle housing fully assembled with PCB contacts for 0.062 (1.57 mm) to 0.093 (2.36 mm) inch boards. NOTE: Shading Indicates Build to Order - 5 - | DRAWINGS | - See Product Drawings on the Website for Additional Information [ 2.2 ] [ 3.0 ] [ 3.08 ] 0.09 26.80 + 0.10 0.12 0.15 0.00 1.055 + 0.004 [ 5.6 ] - 0.000 [ 3.8 ] 0.22 0.15 [ 2.5 ] [ 29.6 ] R. 10 1.17 19.90 + 0.10 MAX TYP. 0.00 [ 0.8 ] 0.783 + 0.004 0.03 - 0.000 Ultra Short Contact Panel Cut Out for All Receptacle Types [ 31.0 ] [ 17.0 ] GROUND 1.22 0.67 [ 5.4 ] [ 3.8 ] 0.21 0.15 [ 26.9 ] [ 24.0 ] 1.06 [ 6.4 ] 0.94 [ 5.0 ] 0.25 [ 17.1 ] 0.20 NEGATIVE (-) (+) POSITIVE 0.67 Flush Mount & Short Contact Ultra Short Depth - For Solder Termination to Wire [ 31.0 ] [ 29.0 ] 1.22 1.14 GROUND [ 24.0 ] 0.94 [ 14.0 ] [ 12.4 ] 0.55 0.49 NEGATIVE (-) (+) POSITIVE Short Depth - For Crimp Termination to Wire [ 40.7 ] [ 33.4 ] 1.60 1.32 GROUND [ 22.6 ] 0.89 [ 24.1 ] 0.95 [ 44.5 ] NEGATIVE (-) (+) POSITIVE 1.75 Flush Mount - For Crimp Termination to Wire [ 1.82 ] [ 2.11 ] [ 1.97 ] [ 0.21 ] 46.3 REF. [ 2.26 ] 53.6 [ 1.60 ] DIM "A" 50.1 5.3 DIM "A" 57.4 40.7 (3) PLC'S (3) PLC'S [ 1.05 ] [ 0.77 ] [ 0.77 ] [ 1.05 ] 26.6 19.7 19.7 26.6 Flush Mount - For Solder Termination to Wire Flush Mount - For Solder Termination to PCB [ 1.71 ] [ 1.42 ] [ 0.55 ] 43.5 [ 0.55 ] 36.1 [ 0.21 ] [ 1.97 ] [ 2.26 ] 14.0 14.0 [ 1.14 ] 5.3 DIM "A" 50.1 57.4 29.0 DIM "A" (3) PLC'S (3) PLC'S [ 1.05 ] [ 1.05 ] [ 0.78 ] 26.7 26.6 [ 0.77 ] 19.8 19.7 Short Depth - For Solder Termination to Wire Short Depth - For Solder Termination to PCB - 6 - | POWER CORDS | - All Plug Types Mate to All Receptacle Types Wide “T” Latch Plug Small Latch Plug Right Angle “T” Latch Plug Wide latch release button across Small latch release button in the Right angle cord over mold to the the top of the plug body to allow center top of the plug body. plug with wide latch button. easy latch access around PSU handles or other obstacles. [ 1.03 ] [ 1.22 ] 26 31 [ 1.03 ] 26.0 [ 0.66 ] [ 0.74 ] [ 0.74 ] [ 0.94 ] [ 2.05 ± 0.04 ] Ø 16.8 18.9 23.9 18.9 52.0 ± 1.0 POSITIVE (+) NEGATIVE (-) NEGATIVE (-) POSITIVE (+) POSITIVE (+) [ 2.90 ± 0.04 ] NEGATIVE (-) GROUND 73.7 ± 1.0 GROUND GROUND 12 AWG 18 - 14 AWG | 1.0mm² - 2.0mm² Simplified Power Connection Design 1. The Same Receptacle is Used on Both the Power & Load Sides. 2. The Same Plug is Used on Both Sides of the Power Cord. 1 3. Both Plug & Receptacle Connectors are Touch Safe. 2 1 2 Ultra Short Receptacle Wide “T” Latch Plug 3 3 ® | Common Cable Types Used in Saf-D-Grid Power Cords | Cable Voltage Jacket Conductor Conductor Insulation Approvals Type Rating Material Insulation Coloring Notes SJT 300V UL, CSA PVC PVC Black, White, Green North American Junior Hard Service, Suitable for Medium Duties in Office or Home, Not Outdoor Rated ST 600V UL, CSA PVC PVC Black, White, Green North American Hard Service, Suitable for Medium Duties in Office or Home, Not Outdoor Rated SOOW 600V UL, CSA Rubber Rubber Black, White, Green North American Extra Hard Service, Outdoor Rated, Oil Resistant HVCT 600V PSE PVC PVC Black, White, Green Japanese, JIS C 3312, Suitable for Medium Duties in Office or Home, Not Outdoor Rated H05VVF 300/500V IEC PVC PVC Blue, Brown, International Harmonized, Suitable for Medium Duties in Office or Home, Not Outdoor Rated Green/Yellow 60245 300/500V CCC Rubber Rubber Blue, Brown, Suitable for Low Mechanical Stress Open Air Environment IEC 57 Green/Yellow NOTE: Reference the plug cordset drawings for exact information on the cable used. Some of the above cables may be for special order use only. Plug cordsets that are available with short lead times are shown in the part number charts of this catalog without a shaded background. Additional cable types may be available on request. Contact customer service. - 7 - Single-Ended “T” Latch Plug Power Cord Length Non-Bulk Std. Bulk Std. M FT Description UL 817 TUV CCC * - Part Numbers - Pack - Part Numbers - Pack 2.0 6.56 12 AWG ST UL 600V 90C 2034KZ2 1 2034KZ2-BK 20 3.0 9.84 12 AWG ST UL 600V 90C 2034KZ3 1 2034KZ3-BK 13 6.0 19.68 12 AWG ST UL 600V 90C 2034KZ6 1 2034KZ6-BK 7 2.0 6.56 14 AWG ST UL 600V 90C • • 2031KZ2 1 2031KZ2-BK 50 3.0 9.84 14 AWG ST UL 600V 90C • • 2031KZ3 1 2031KZ3-BK 30 6.0 19.68 14 AWG ST UL 600V 90C • • 2031KZ6 1 2031KZ6-BK 6 2.0 6.56 16 AWG ST UL 600V 90C • • 2036KZ2 1 2036KZ2-BK 50 3.0 9.84 16 AWG ST UL 600V 90C • • 2036KZ3 1 2036KZ3-BK 30 6.0 19.68 16 AWG ST UL 600V 90C • • 2036KZ6 1 2036KZ6-BK 6 2.0 6.56 18 AWG ST UL 600V 90C • • 2033KZ2 1 2033KZ2-BK 50 3.0 9.84 18 AWG ST UL 600V 90C • • 2033KZ3 1 2033KZ3-BK 30 6.0 19.68 18 AWG ST UL 600V 90C • • 2033KZ6 1 2033KZ6-BK 6 2.0 6.56 1.0 mm² H05VVF CE 500/300V 75C 2043KZ2 1 2043KZ2-BK 50 3.0 9.84 1.0 mm² H05VVF CE 500/300V 75C 2043KZ3 1 2043KZ3-BK 30 6.0 19.68 1.0 mm² H05VVF CE 500/300V 75C 2043KZ6 1 2043KZ6-BK 6 2.0 6.56 1.5 mm² H05VVF CE 500/300V 75C • 2047KZ2 1 2047KZ2-BK 50 3.0 9.84 1.5 mm² H05VVF CE 500/300V 75C • 2047KZ3 1 2047KZ3-BK 30 6.0 19.68 1.5 mm² H05VVF CE 500/300V 75C • 2047KZ6 1 2047KZ6-BK 6 2.0 6.56 2.5 mm² 60245 IEC 57 / CCC 500/300V 60C • 2045KZ2 1 2045KZ2-BK 50 3.0 9.84 2.5 mm² 60245 IEC 57 / CCC 500/300V 60C • 2045KZ3 1 2045KZ3-BK 30 6.0 19.68 2.5 mm² 60245 IEC 57 / CCC 500/300V 60C • 2045KZ6 1 2045KZ6-BK 6 2.0 6.56 1.0 mm² HVCT PSE 600V 75C 2023KZ2 1 2023KZ2-BK 50 3.0 9.84 1.0 mm² HVCT PSE 600V 75C 2023KZ3 1 2023KZ3-BK 30 6.0 19.68 1.0 mm² HVCT PSE 600V 75C 2023KZ6 1 2023KZ6-BK 6 2.0 6.56 1.25 mm² HVCT PSE 600V 75C 2025KZ2 1 2025KZ2-BK 50 3.0 9.84 1.25 mm² HVCT PSE 600V 75C 2025KZ3 1 2025KZ3-BK 30 6.0 19.68 1.25 mm² HVCT PSE 600V 75C 2025KZ6 1 2025KZ6-BK 6 2.0 6.56 2.0 mm² HVCT PSE 600V 75C 2021KZ2 1 2021KZ2-BK 50 3.0 9.84 2.0 mm² HVCT PSE 600V 75C 2021KZ3 1 2021KZ3-BK 30 6.0 19.68 2.0 mm² HVCT PSE 600V 75C 2021KZ6 1 2021KZ6-BK 6 * CCC Pending L Top View Single Ended Plug Assembly Single-Ended Small Latch Plug Power Cord Length Non-Bulk Std. Bulk Std. M FT Description UL 817 TUV - Part Numbers - Pack - Part Numbers - Pack 2.0 6.56 12 AWG ST UL 600V 90C 2034G2 1 2034G2-BK 20 3.0 9.84 12 AWG ST UL 600V 90C 2034G3 1 2034G3-BK 13 6.0 19.68 12 AWG ST UL 600V 90C 2034G6 1 2034G6-BK 7 2.0 6.56 14 AWG ST UL 600V 90C • • 2030G2 1 2030G2-BK 50 3.0 9.84 14 AWG ST UL 600V 90C • • 2030G3 1 2030G3-BK 30 6.0 19.68 14 AWG ST UL 600V 90C • • 2030G6 1 2030G6-BK 6 2.0 6.56 18 AWG ST UL 600V 90C • • 2032G2 1 2032G2-BK 50 3.0 9.84 18 AWG ST UL 600V 90C • • 2032G3 1 2032G3-BK 30 6.0 19.68 18 AWG ST UL 600V 90C • • 2032G6 1 2032G6-BK 6 2.0 6.56 1.5 mm² H05VVF CE 500/300V 75C • 2040G2 1 2040G2-BK 50 3.0 9.84 1.5 mm² H05VVF CE 500/300V 75C • 2040G3 1 2040G3-BK 30 6.0 19.68 1.5 mm² H05VVF CE 500/300V 75C • 2040G6 1 2040G6-BK 6 1.5 4.92 2.0 mm² HVCT PSE 600V 75C 2020G1 1 2020G1-BK 50 2.0 6.56 2.0 mm² HVCT PSE 600V 75C 2020G2 1 2020G2-BK 50 3.0 9.84 2.0 mm² HVCT PSE 600V 75C 2020G3 1 2020G3-BK 30 6.0 19.68 2.0 mm² HVCT PSE 600V 75C 2020G6 1 2020G6-BK 6 L Top View Single Ended Plug Assembly NOTE: Shading Indicates Build to Order - 8 - Single-Ended Right Angle “T” Latch Plug Power Cord Length Non-Bulk Std. Bulk Std. M FT Description UL 817 TUV - Part Numbers - Pack - Part Numbers - Pack 2.0 6.56 14 AWG ST UL 600V 90C • • 2031LZ2 1 2031LZ2-BK 50 3.0 9.84 14 AWG ST UL 600V 90C • • 2031LZ3 1 2031LZ3-BK 30 6.0 19.68 14 AWG ST UL 600V 90C • • 2031LZ6 1 2031LZ6-BK 6 2.0 6.56 16 AWG ST UL 600V 90C • 2036LZ2 1 2036LZ2-BK 50 3.0 9.84 16 AWG ST UL 600V 90C • 2036LZ3 1 2036LZ3-BK 30 6.0 19.68 16 AWG ST UL 600V 90C • 2036LZ6 1 2036LZ6-BK 6 2.0 6.56 18 AWG ST UL 600V 90C • 2033LZ2 1 2033LZ2-BK 50 3.0 9.84 18 AWG ST UL 600V 90C • 2033LZ3 1 2033LZ3-BK 30 6.0 19.68 18 AWG ST UL 600V 90C • 2033LZ6 1 2033LZ6-BK 6 2.0 6.56 2.0 mm² HVCT PSE 600V 75C 2021LZ2 1 2021LZ2-BK 50 3.0 9.84 2.0 mm² HVCT PSE 600V 75C 2021LZ3 1 2021LZ3-BK 30 6.0 19.68 2.0 mm² HVCT PSE 600V 75C 2021LZ6 1 2021LZ6-BK 6 L Double-Ended “T” Latch Plug Power Cord Length Non-Bulk Std. Bulk Std. M FT Description UL 817 TUV CCC * - Part Numbers - Pack - Part Numbers - Pack 2.0 6.56 12 AWG ST UL 600V 90C 2035KK2 1 2035KK2-BK 20 3.0 9.84 12 AWG ST UL 600V 90C 2035KK3 1 2035KK3-BK 13 6.0 19.68 12 AWG ST UL 600V 90C 2035KK6 1 2035KK6-BK 7 2.0 6.56 14 AWG ST UL 600V 90C • • 2031KK2 1 2031KK2-BK 50 3.0 9.84 14 AWG ST UL 600V 90C • • 2031KK3 1 2031KK3-BK 30 6.0 19.68 14 AWG ST UL 600V 90C • • 2031KK6 1 2031KK6-BK 6 2.0 6.56 16 AWG ST UL 600V 90C • • 2036KK2 1 2036KK2-BK 50 3.0 9.84 16 AWG ST UL 600V 90C • • 2036KK3 1 2036KK3-BK 30 6.0 19.68 16 AWG ST UL 600V 90C • • 2036KK6 1 2036KK6-BK 6 2.0 6.56 18 AWG ST UL 600V 90C • • 2033KK2 1 2033KK2-BK 50 3.0 9.84 18 AWG ST UL 600V 90C • • 2033KK3 1 2033KK3-BK 30 6.0 19.68 18 AWG ST UL 600V 90C • • 2033KK6 1 2033KK6-BK 6 2.0 6.56 1.0 mm² H05VVF CE 500/300V 75C 2043KK2 1 2043KK2-BK 50 3.0 9.84 1.0 mm² H05VVF CE 500/300V 75C 2043KK3 1 2043KK3-BK 30 6.0 19.68 1.0 mm² H05VVF CE 500/300V 75C 2043KK6 1 2043KK6-BK 6 2.0 6.56 1.5 mm² H05VVF CE 500/300V 75C • 2047KK2 1 2047KK2-BK 50 3.0 9.84 1.5 mm² H05VVF CE 500/300V 75C • 2047KK3 1 2047KK3-BK 30 6.0 19.68 1.5 mm² H05VVF CE 500/300V 75C • 2047KK6 1 2047KK6-BK 6 2.0 6.56 2.5 mm² 60245 IEC 57 / CCC 500/300V 60C • 2045KK2 1 2045KK2-BK 50 3.0 9.84 2.5 mm² 60245 IEC 57 / CCC 500/300V 60C • 2045KK3 1 2045KK3-BK 30 6.0 19.68 2.5 mm² 60245 IEC 57 / CCC 500/300V 60C • 2045KK6 1 2045KK6-BK 6 2.0 6.56 1.0 mm² HVCT PSE 600V 75C 2023KK2 1 2023KK2-BK 50 3.0 9.84 1.0 mm² HVCT PSE 600V 75C 2023KK3 1 2023KK3-BK 30 6.0 19.68 1.0 mm² HVCT PSE 600V 75C 2023KK6 1 2023KK6-BK 6 2.0 6.56 1.25 mm² HVCT PSE 600V 75C 2025KK2 1 2025KK2-BK 50 3.0 9.84 1.25 mm² HVCT PSE 600V 75C 2025KK3 1 2025KK3-BK 30 6.0 19.68 1.25 mm² HVCT PSE 600V 75C 2025KK6 1 2025KK6-BK 6 2.0 6.56 2.0 mm² HVCT PSE 600V 75C 2021KK2 1 2021KK2-BK 50 3.0 9.84 2.0 mm² HVCT PSE 600V 75C 2021KK3 1 2021KK3-BK 30 6.0 19.68 2.0 mm² HVCT PSE 600V 75C 2021KK6 1 2021KK6-BK 6 L * CCC Pending Top View Double Ended Plug Assembly NOTE: Shading Indicates Build to Order - 9 - Double-Ended Small Latch Plug Power Cord Length Non-Bulk Std. Bulk Std M FT Description UL 817 TUV - Part Numbers - Pack - Part Numbers - Pack 2.0 6.56 12 AWG ST UL 600V 90C 2035G2 1 2035G2-BK 20 3.0 9.84 12 AWG ST UL 600V 90C 2035G3 1 2035G3-BK 13 6.0 19.68 12 AWG ST UL 600V 90C 2035G6 1 2035G6-BK 7 2.0 6.56 14 AWG ST UL 600V 90C • • 2031G2 1 2031G2-BK 50 3.0 9.84 14 AWG ST UL 600V 90C • • 2031G3 1 2031G3-BK 30 6.0 19.68 14 AWG ST UL 600V 90C • • 2031G6 1 2031G6-BK 6 2.0 6.56 18 AWG ST UL 600V 90C • • 2033G2 1 2033G2-BK 50 3.0 9.84 18 AWG ST UL 600V 90C • • 2033G3 1 2033G3-BK 30 6.0 19.68 18 AWG ST UL 600V 90C • • 2033G6 1 2033G6-BK 6 2.0 6.56 1.5 mm² H05VVF CE 500/300V 75C • 2041G2 1 2041G2-BK 50 3.0 9.84 1.5 mm² H05VVF CE 500/300V 75C • 2041G3 1 2041G3-BK 30 6.0 19.68 1.5 mm² H05VVF CE 500/300V 75C • 2041G6 1 2041G6-BK 6 2.0 6.56 2.0 mm² HVCT PSE 600V 75C 2021G2 1 2021G2-BK 50 3.0 9.84 2.0 mm² HVCT PSE 600V 75C 2021G3 1 2021G3-BK 30 6.0 19.68 2.0 mm² HVCT PSE 600V 75C 2021G6 1 2021G6-BK 6 L Top View Double-Ended “T” Latch / IEC C20 Power Cord Length Non-Bulk Std. Bulk Std. M FT Description UL 817 TUV* - Part Numbers - Pack - Part Numbers - Pack 2.0 6.56 14 AWG SJT UL 250V 105C • • 2052KH2 1 2052KH2-BK 50 3.0 9.84 14 AWG SJT UL 250V 105C • • 2052KH3 1 2052KH3-BK 30 6.0 19.68 14 AWG SJT UL 250V 105C • • 2052KH6 1 2052KH6-BK 6 * TUV applies only to Saf-D-Grid® connector side. L Top View Saf-D-Grid Plug IEC C20 Plug Double-Ended Right Angle “T” Latch / Straight “T” Latch Plug Power Cord Length Non-Bulk Std. Bulk Std. M FT Description UL 817 TUV - Part Numbers - Pack - Part Numbers - Pack 2.0 6.56 14 AWG ST UL 600V 90C • • 2031KL2 1 2031KL2-BK 50 3.0 9.84 14 AWG ST UL 600V 90C • • 2031KL3 1 2031KL3-BK 30 6.0 19.68 14 AWG ST UL 600V 90C • • 2031KL6 1 2031KL6-BK 6 2.0 6.56 16 AWG ST UL 600V 90C • 2036KL2 1 2036KL2-BK 50 3.0 9.84 16 AWG ST UL 600V 90C • 2036KL3 1 2036KL3-BK 30 6.0 19.68 16 AWG ST UL 600V 90C • 2036KL6 1 2036KL6-BK 6 2.0 6.56 18 AWG ST UL 600V 90C • 2033KL2 1 2033KL2-BK 50 3.0 9.84 18 AWG ST UL 600V 90C • 2033KL3 1 2033KL3-BK 30 6.0 19.68 18 AWG ST UL 600V 90C • 2033KL6 1 2033KL3-BK 6 2.0 6.56 2.0 mm² HVCT PSE 600V 75C 2021KL2 1 2021KL2-BK 50 3.0 9.84 2.0 mm² HVCT PSE 600V 75C 2021KL3 1 2021KL3-BK 30 6.0 19.68 2.0 mm² HVCT PSE 600V 75C 2021KL6 1 2021KL6-BK 6 L NOTE: Shading Indicates Build to Order - 10 - Double-Ended Right Angle “T” Latch / Right Angle “T” Latch Power Cord Length Non-Bulk Std. Bulk Std. M FT Description UL 817 TUV - Part Numbers - Pack - Part Numbers - Pack 2.0 6.56 14 AWG ST UL 600V 90C • • 2031LL2 1 2031LL2-BK 50 3.0 9.84 14 AWG ST UL 600V 90C • • 2031LL3 1 2031LL3-BK 30 6.0 19.68 14 AWG ST UL 600V 90C • • 2031LL6 1 2031LL6-BK 6 2.0 6.56 16 AWG ST UL 600V 90C • 2036LL2 1 2036LL2-BK 50 3.0 9.84 16 AWG ST UL 600V 90C • 2036LL3 1 2036LL3-BK 30 6.0 19.68 16 AWG ST UL 600V 90C • 2036LL6 1 2036LL6-BK 6 2.0 6.56 18 AWG ST UL 600V 90C • 2033LL2 1 2033LL2-BK 50 3.0 9.84 18 AWG ST UL 600V 90C • 2033LL3 1 2033LL3-BK 30 6.0 19.68 18 AWG ST UL 600V 90C • 2033LL6 1 2033LL6-BK 6 2.0 6.56 2.0 mm² HVCT PSE 600V 75C 2021LL2 1 2021LL2-BK 50 3.0 9.84 2.0 mm² HVCT PSE 600V 75C 2021LL3 1 2021LL3-BK 30 6.0 19.68 2.0 mm² HVCT PSE 600V 75C 2021LL6 1 2021LL6-BK 6 L Double-Ended Right Angle “T” Latch / Left Angle “T” Latch Power Cord Length Non-Bulk Std. Bulk Std. M FT Description UL 817 TUV - Part Numbers - Pack - Part Numbers - Pack 2.0 6.56 14 AWG ST UL 600V 90C • • 2031LM2 1 2031LM2-BK 50 3.0 9.84 14 AWG ST UL 600V 90C • • 2031LM3 1 2031LM3-BK 30 6.0 19.68 14 AWG ST UL 600V 90C • • 2031LM6 1 2031LM6-BK 6 2.0 6.56 16 AWG ST UL 600V 90C • 2036LM2 1 2036LM2-BK 50 3.0 9.84 16 AWG ST UL 600V 90C • 2036LM3 1 2036LM3-BK 30 6.0 19.68 16 AWG ST UL 600V 90C • 2036LM6 1 2036LM6-BK 6 2.0 6.56 18 AWG ST UL 600V 90C • 2033LM2 1 2033LM2-BK 50 3.0 9.84 18 AWG ST UL 600V 90C • 2033LM3 1 2033LM3-BK 30 6.0 19.68 18 AWG ST UL 600V 90C • 2033LM6 1 2033LM6-BK 6 2.0 6.56 2.0 mm² HVCT PSE 600V 75C 2021LM2 1 2021LM2-BK 50 3.0 9.84 2.0 mm² HVCT PSE 600V 75C 2021LM3 1 2021LM3-BK 30 6.0 19.68 2.0 mm² HVCT PSE 600V 75C 2021LM6 1 2021LM6-BK 6 L NOTE: Shading Indicates Build to Order - 11 - DC Electrical Power Distribution Systems DC Efficiency DC electrical distribution systems have a basic advantage over AC systems. By eliminating AC to DC conversions a DC distribution system is simpler than an AC system. With less electrical and electronic devices, a DC system can be designed with lower electrical losses and higher reliability. These advan- tages are further multiplied for systems having DC energy storage for backup power or peak shaving, or a local DC energy source such as photovoltaic cells, wind turbines or fuel cells. Standardization ® APP has been a leader in the development of system and product safety standards for low voltage DC. We are active on key product and safety commit- ® tees within the EMerge Alliance , NEMA and the IEC. ® Saf-D-Grid meets or exceeds all relevant industry safety standards. The product has also been successfully tested to new product safety standards under consideration for adoption. ® On September 26, 2012 the Emerge Alliance board of directors ratified the Emerge Standard for DC Power Distribution Systems (DC-PDS) in Data & ® ® Telecom Centers (DTC). Within the Standard, the APP Saf-D-Grid connector system is designated as the interconnection of choice for power strip, power cord and device inlet power connections. DC Arcing AC system voltage phases cause the voltage to pass through zero at some point during the disconnection sequence. This zero crossing significantly reduces the damage to a contact system from an AC arc. DC arcing is more destructive to contact systems due to the lack of phasing to a zero voltage ® ® point. The APP Saf-D-Grid connector overcame this technical challenge by using adequate contact mass, arc reducing geometry, and a sacrificial ® contact tip. Saf-D-Grid has undamaged electrical contact surfaces after 250 DC arcing cycles. DC Safety There is near global acceptance that 380V is the most practical voltage for low voltage DC distribution systems. By using a center-point ground, a +/- 190 volt DC distribution system can be constructed which has lower risk of electrocution than the 200-250 VAC systems installed throughout the world. The ® system can additionally be made safe by using connectors such as Saf-D-Grid , which meet IEC and UL finger probe requirements for touch safety and ® have a latching system to avoid accidental disconnection. Saf-D-Grid also has adequate voltage isolation to contain arcing from disconnection within the ® ® insulating housings. Video of the disconnection of APP Saf-D-Grid connectors under load shows extinguishing of the internal arc well in advance of the connector separation and potential exposure to the user. ® The Saf-D-Grid connector applies to power supplies and PDU’s inside information and communication technology racks. EMerge Alliance is a registered trademark of the EMerge Alliance Industry Association NEMA is a registered trademark of the National Electric Manufacturers Association All Data Subject To Change Without Notice 15709 DS-SDG REV 15 “Saf-D-Grid, APP and Anderson Power Products are registered trademarks of Anderson Power Products” ® ® HEADQUARTERS: Anderson Power Products , 13 Pratts Junction Road, Sterling, MA 01564-2305 USA T:978-422-3600 F:978-422-0128 • EUROPE: Anderson Power Products Ltd., Unit 3, Europa Court, Europa Boulevard, Westbrook, Warrington, Cheshire, WA5 7TN United Kingdom T: +44 (0) 1925 428390 F: +44 (0) 1925 520203 • ASIA / PACIFIC: IDEAL Anderson Asia Pacific Ltd., Unit 922-928 Topsail Plaza, 11 On Sum Street, Shatin N.T., Hong Kong T:+(852) 2636 0836 F:+(852) 2635 9036 • CHINA: IDEAL Anderson Technologies (Shenzhen) Ltd., Block A8 Tantou Western Industrial Park, Songgang Baoan District, Shenzhen, PR. China 518105 T: +(86) 755 2768 2118 F: +(86) 755 2768 2218 • TAIWAN: IDEAL Anderson Asia Pacific Ltd., Taiwan Branch, 4F.-2, No.116, Dadun 20th St., Situn District, Taichung City 407, Taiwan (R.O.C.) T: +(886) 4 2310 6451 F:+(886) 4 2310 6460 • www.andersonpower.com

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the 2002G3KIT?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Conn Power PIN 1 POS Crimp ST Cable Mount 1 Terminal 1 Port 1201G1

product

Conn Power SKT 1Power POS ST Cable Mount 1 Terminal 1 Port 1300

product

Conn Power SKT 1Power POS ST Cable Mount 1 Terminal 1 Port 1300G2

product

Conn Power SKT 1Power POS ST Cable Mount 1 Terminal 1 Port 1300G3

product

Conn Power SKT 1Power POS ST Cable Mount 1 Terminal 1 Port 1300G4

product

Conn Power SKT 1Power POS ST Cable Mount 1 Terminal 1 Port 1300G5