Electronics Finder chervon right Manufacturers chervon right C chervon right CARLING TECHNOLOGIES chervon right 999-16716-001
About product Specifications Datasheet FAQ

CARLING TECHNOLOGIES 999-16716-001

Image of CARLING TECHNOLOGIES 999-16716-001

Description

Conn Housing RCP 8 POS Crimp ST Cable Mount
999-16716-001

Part Number

999-16716-001

Price

Request Quote

Manufacturer

CARLING TECHNOLOGIES

Lead Time

Request Quote

Category

Connectors »  Connector Discrete Wire Housing

Specifications

Manufacturer

Carling Technologies

Manufacturers Part #

999-16716-001

Industry Aliases

999-16716-001

Sub-Category

Discrete Wire Housing Connectors

Factory Pack Quantity

1

Datasheet

pdf file

V-Series_Details_%26_COS_111213.pdf

4638 KiB

Extracted Text

V-Series V-Series CONTURA SWITCHES Carling Technologies’ sealed V-Series Contura switches are well known for their cutting edge design, high quality, maximum performance and unmatched reliability. These switches are a staple in the marine and transportation industries and have passed a range of environmental, corrosion, temperature, vibration, shock and sealing tests including MIL Std 202F, MIL Std 510.1, UL 1500, ISO 8846, IEC 60529 and BS 5490 among others, making them one of the most rugged and reliable switches ever manufactured. Resources: Download 3D CAD Files IGS STP Watch Product Video Product Highlights: Typical Applications: Š Š Certified to IP66/68 with dual seals around lamps Marine Panels Š and rocker stem. Emergency Vehicles Š Š Silver plated butt contact mechanism provides Trucks Š reliability up to and beyond 100K electrical cycles Buses Š Š Greaseless construction withstands temperature Construction Equipment Š extremes down to -40˚C Motorcycles & ATVs Š Š The switch accommodates up to 10 terminals and Farm Equipment Š endless illumination and circuit options. Commercial Appliances Š Š The switch connector allows the user to preload Military Vehicles Š FQC terminals for ease of assembly. Mining Equipment Š Š Numerous choices of removable rockers allow for Golf Carts Š style change without having to retest or re-qualify Floor Cleaning Equipment Š the switch base. Utility Vehicles Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com www.carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 | 2 V-Series Contura Sealed Rocker Switches - Design Features V-Series Switch DESIGN FEATURES INTERCHANGEABLE ACTUATORS DUAL SEAL PROTECTION CLEAN CONNECTIONS Panel redesign is a snap with our wide Seals out water, dust, Options for both eight and ten range of rocker styles. Achieve maximum debris, and enables switch terminal base styles with AMP & design variety with minimum inventory. certification to IP66/68 for Packard compatible connectors Simply swap rockers to create an entirely front panel components. affords myriad circuit options new look for your panel. while providing ease of assembly. MULTIPLE LIGHTING OPTIONS BRASS ROLLER PIN SILVER PLATED BUTT OPTIONAL PANEL SEAL In addition to Incandescent Robust mechanism CONTACT MECHANISM Helps prevent water/dust lamps, our LED illumination is eliminates the need for Providing 50k to 100k ingress behind panel. offered in a wide array of light lubricants. Enables switch electrical cycles and intensities, colors, as well as to withstand -40°C to a variety of different dual level, tri-color, and flashing +85°C temperatures. electrical ratings. options. *Manufacturer reserves the right to change product specification without prior notice. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com V-Series Contura Sealed Rocker Switches - Actuator Options & Accessories | 3 Contura II & III Contura X The Contura II & III actuators are The raised bracket/bezel on the constructed of thermoplastic Contura X helps prevent inadvertent polycarbonate and are offered with actuation of the rocker, as well as a hard nylon overlay or a “soft-touch” preventing debris from being trapped elastomer overlay. These models under the actuator. This curved rocker incorporate aesthetic designs on style is available with a variety of the top and bottom of the rocker lenses and legends. featuring two rows of raised “bumps” on the Contura II and three “indented” lines on the Contura III. Contura IV Contura XI The Contura IV’s “Shape to create The raised bracket/bezel on the a Shape” actuator works with the Contura XI helps prevent inadvertent curves, contours & advanced styling actuation of the rocker, as well as of the latest panel designs, flowing preventing debris from being trapped with these advanced curves & radii. under the actuator. This convex style This actuator style fits on the Contura rocker is available with a wide variety flush bracket/bezel. of lenses and legends. Contura XII Contura V The Contura XII version features a The symmetrically curved Contura paddle style actuator with the raised V actuator provides the perfect bracket/bezel of Contura X and XI. The complement to the Contura IV’s contoured handle design provides “Shape to create a Shape” design intuitive recognition and ease of concept. With its flush style mounting operation and is available with all bracket, Contura V can be mounted in Contura X and XI lens and legend between two Contura IV’s, by itself, or offerings. in groups. Contura VI (WAVE) Contura XIV The Contura VI WAVE sealed rocker The Contura XIV represents a sleek new switches, when used in a row, create crossover rocker design which should an uniquely appealing “wave” design appeal to Trucks, Buses and Heavy on your panel. A variety of colors and Vehicles as well as the Marine Industry. finishes are available for both rocker Intuitive feel is provided by recessed and wave insert. Contura VI features ridges along with a Center Groove bar and oval lenses. which effectively defines the boundary between top and bottom switch functions. Contura VII Illuminated Indicators Contura VII featuring gently & Accessories curved corners and edges assuring Alert operator of systems functions compatibility with most any panel or malfunctions, are offered with design. Intuitive feel is maximized removable/replaceable lamps in by the use of 2 embossed circular Contura II, II, V or X styles. Accessories pads located at opposite ends of include connectors, mounting panels, the rocker. Any combination of Bar hole plugs, panel seals, and actuator or Oval style lenses can be located removal tools. Refer to accessories page in the pads providing a truly unique for full details look, exclusive to Contura VII. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 4 V–Series Contura Sealed Rocker Switches - General Specifications Electrical Agency Certifications Contact Rating .4VA @ 24VDC (MAX) resistive 15 amps, 125VAC 10 amps, 250VAC 1/2 HP 125-250VAC 20 amps, 4-14VDC Environmental 15 amps, 15-28VDC 10A, 14VT Sealing Sealed version: IP66/68, this rating applies to front panel components of 6A, 125VAC L the actual switch only, and signifies Dielectric Strength 1500 Volts RMS complete protection against dust as Insulation Resistance 50 Megohms well as powerful jets of water. Initial Contact Resistance 10 milliohms max. @ 4VDC Corrosion Mixed Flowing Gas (MFG) Class III Life 50,000 - 100,000 cycles circuit 3 year accelerated exposure per dependent ASTM B-827, B-845 Silver and gold Contacts Silver alloy, silver tin-oxide, fine contacts silver Operating Temp. -40°C to +85°C Terminals Brass or copper/silver plate 1/4” Vibration 1 Per Mil-Std 202F, Method 204D (6.3mm) Quick Connect Test Condition A 0.06 DA or 10G’s terminations standard. Solder lug, 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during Wire Lead test, pre and post test contact resistance. Mechanical Vibration 2 Resonance search Endurance 150,000 cycles minimum 24-50 Hz 0.40 DA circuit dependent 50-2000 Hz ±10 G’s peak Horizontal Axis 3-5 G’s max. Random Physical 24 Hz 0.06 PSD-Gsq/Hz Lighted Incandescent - rated 10,000 60 Hz 0.50 hours Neon - rated 25,000 hours 100 Hz 0.50 LED - rated 100,000 hours 1/2 life 200 Hz 0.025 (LED is internally ballasted for 2000 Hz 0.025 voltages to 24VDC) No loss of circuit during test; <10μ Seals Internal seconds chatter. Optional external gasket panel seal Shock Per Mil-Std 202F, Method 213B, Test Base Polyester blend rated to 125°C with Condition K @ 30G’s. Tested with VCH connector. Test criteria - No loss a UL flammability rating of 94V0. of circuit during test, pre and post Contura II,III,IV,V, Hard Surface: Basic actuator test contact resistance. VI, VII Actuator structure molded of thermoplastic Salt Spray Per Mil-Std 202F, Method 101D, Test polycarbonate with a hard Nylon 66 Condition A, 96 Hrs. Sealed version only. thermoplastic surface overlay. Dust Mil STD 810, Method 510.2 Air Velocity Soft Surface: Basic actuator structure 300 Ft/Min Duration 16Hr molded of thermoplastic polycarbonate Thermal Shock Per Mil-Std 202F, Method 107F, Test with an elastomer overlay. Cond. A, -55°C to +85°C. Test criteria - Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C pre and post test contact resistance Lens Polycarbonate rated at 100°C Moisture Resistance Per Mil-Std 202F, Method 106F, Test Criteria - pre and post test contact Contura XIV Polycarbonate lens/sub-rocker with resistance ABS shell Ignition Protection All Contura switches with sealed construction meet the requirements Actuator Travel (Angular Displacement) of UL1500/ISO8846 for ignition 2 position 18° protection, in addition to 3 positions 9° from center conformance with EC directive 94/25/EC for marine products. Mounting Specifications .830[21.08] Panel Thickness Range Gaskets Acceptable Panel Thickness 0 .030 to .250 (.76 to 6.35mm) TEST CUT HOLE IN 1.450[36.83] 1 .030 to .109 & .147 to .157 ACTUAL MATERIAL (.76 to 2.77mm & 3.73 to 3.98mm) Recommended: No gasket with panel SWITCH thickness of .032, .062, .093, .125,.187 or .250 MOUNTING HOLE Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com V-Series Contura Sealed Rocker Switches- Contura II & III - Ordering Scheme | 5 V 1 D A B T 0 B A R B 00 0 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Color Legend Legend Actuator Orientation Lens Legend 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) 1 SERIES Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V 2 - - 5 2 - - 5 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 1 8 FLUSH BRACKET COLOR , PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 Black White Gray 1 A ON NONE OFF No Seal B W G 2 B (ON) NONE OFF 3 C ON NONE (OFF) One Seal C Y H 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 9 ACTUATOR 7 K ON OFF (ON) 0 No Actuator 8 L (ON) OFF (ON) A, B Contura II SPECIAL CIRCUITS C, D Contura III H* 2 & 3 2 & 3, 5 & 4 5 & 4 G* 2 & 3, 5 & 6 2 & 3 OFF Actuator thick end over terminals: 3,6 1,4 S* 2 & 3, 5 & 6 2 & 3 1 & 2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 10 LENS E* 5 & 6 5 & 3 5 & 1 0 - No Actuator Z - No Lens *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in Clear White Amber Green Red Blue selection 4. External jumper between terminals 2 & 4 for circuit E are 1 6 8 G M T provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 2 7 C H N U 3 8 D J P V 3 3 RATING Square lens options only available for Contura II. 1 .4VA @ 28VDC Resistive 4 9 E K R W B 15A 24V 5 A F L S Y C 20A 18V Lens color for LEDs must be clear, white, or match color of LED. D 20A 12V Green or blue lenses are not recommended with Neon lamps. E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V 1 11 ACTUATOR COLOR AND TEXTURE N .4VA/15A 24V 0 - No Actuator Black Gray Red White Soft Surface B G R W 4 TERMINATION / BASE STYLE Hard Surface C H S Y 8 term 10 Term Termination Jumper 1 2 .250 TAB (QC) no barriers No A B .250 TAB (QC) with barriers No 2 12 ACTUATOR LENS OR BODY LEGENDS J K .250 TAB (QC) no barriers Yes T2 to 5 11 ON 12 OFF 13 I 14 O 3 5 Solder Lug no barriers No OFF ON O I C D Solder Lug No 5 6 Wire Leads no barriers No 15 O O 16 O O 17 O I 18 I O E F Wire Leads No F N N F Note: Codes J & K for circuits H, G & M. Do not use silicone based F F lubricants to reduce terminal insertion forces during connector assembly, For additional legend options & codes, visit us at www.carlingtech.com. as it is detrimental to function and performance. 13 LEGEND ORIENTATION 5 ILLUMINATION 0 No legend (used with codes 11-18 in selection 12) Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 1 Orientation 1 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED 2 Orientation 2 lamps only 3 Orientation 3 Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 4 Orientation 4 S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) 1 2 3 4 D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 14 ACTUATOR LENS LEGEND 2 UP 3 (+) 7 (–) 00 No legend this location / no actuator F 6 1 INDEPENDENT 8 (+) 7 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch 2 UP 3 (+) 6 (–) requires two legends. If the two legends consist of one lens and one G 7 1 INDEPENDENT 8 (+) 7 (–) body legend, lens legend must be specified in selection 12; body legend 2 UP 3 (+) 7 (–) specified in selection 14. H Z 2 INDEPENDENT 8 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) Notes: SINGLE POLE SWITCHES ONLY Consult factory to verify horsepower rating for your particular circuit choice. J 8 1 DOWN 3 (+) 8 (–) 1 Custom colors are available. Consult factory. 2 INDEPENDENT 6 (+) 7 (–) 2 Body legends not available on Soft surface actuators; White imprinting is standard K W 1 INDEPENDENT 8 (+) 7 (–) on black actuators; Black imprinting is standard on white, red and gray actuators. 2 INDEPENDENT 6 (+) 7 (–) Custom colors are available, consult factory. DOUBLE POLE SWITCHES ONLY 3 Additional ratings available. See V-Series Switch Accessories page. L 9 1 DOWN 3 (+) 6 (–) 4 Contura II available with two square lenses. Consult factory for details. M R 1 UP 3 (+) 6 (–) N T 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) P V 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 6 V-Series Contura Sealed Rocker Switches - Contura II & III Locking - Ordering Scheme V 1 D A S W 0 B A Z E 00 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Bracket Actuator Lens Function Legend Legend Series Circuit Rating Termination Illumination Lock Lamp Orientation 1 SERIES 7 LAMP V Lamp above terminals 3 & 6 end of switch No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V * Consult factory for “daylight bright” LED options. Typical current draw for 2 - - 5 2 - - 5 LED is 20ma. 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 1 8 FLUSH BRACKET COLOR , PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 Black White Gray 1 A ON NONE OFF No Seal B W G 4 D ON NONE ON One Seal C Y H 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) 1 9 N OFF NONE ON 9 HARD SURFACE ACTUATOR SPECIAL CIRCUITS Black Gray Red White H* 2 & 3 2 & 3, 5 & 4 5 & 4 Contura II A B G H G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1 & 2 Contura III C D E F M* (2 & 3, 5 & 6) 2 & 3 OFF 3,6 1,4 R* (2 & 3, 5 & 6) 2 & 3 2 & 1 Actuator orientation above terminals: E* 5 & 6 5 & 3 5 & 1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are 10 LENS provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. Z - No Lens Clear White Amber Green Red Blue 3 8 D J P V 4 3 RATING 1 .4VA @ 28VDC Resistive Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. B 15A 24V C 20A 18V D 20A 12V 1 E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 11 ACTUATOR LOCK FUNCTION AND COLOR 3 F 10A 14V, 6A 14VT (circuit G only) Lock Color Up Down Up & Down Center M .4VA/20A 12V Match Actuator A H R 1 N .4VA/15A 24V Black B J S 2 White C K T 3 Red D L V 4 4 TERMINATION / BASE STYLE Safety Orange E M W 5 8 term 10 Term Termination Jumper 1 2 .250 TAB (QC) no barriers No 2 A B .250 TAB (QC) with barriers No 12 ACTUATOR LENS OR BODY LEGEND J K .250 TAB (QC) no barriers Yes T2 to 5 00 - No Legend 3 5 Solder Lug no barriers No 21 22 23 24 C D Solder Lug No OFF ON O I 5 6 Wire Leads no barriers No E F Wire Leads No 25 O 26 O 27 O 28 I Note: Codes J & K for circuits H, G & M. Do not use silicone based F N lubricants to reduce terminal insertion forces during connector assembly, F For additional legend options & codes, visit us at www.carlingtech.com. as it is detrimental to function and performance. 13 LEGEND ORIENTATION 5 ILLUMINATION & SWITCH SEALING 0 No legend (used with codes 21-28 in selection 12) Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 1 Orientation 1 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED 2 Orientation 2 lamps only 3 Orientation 3 Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 4 Orientation 4 S 0 NONE – – C 3 2 UP 3 (+) 7 (–) 1 2 3 4 H Z 2 INDEPENDENT 8 (+) 7 (–) DOUBLE POLE SWITCHES ONLY M R 1 UP 3 (+) 6 (–) 6 LOCK Lock above terminals 1 & 4 end of switch W lock Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function. 4 Additional ratings available. See V-Series Switch Accessories page. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com V-Series Contura Sealed Rocker Switches - Contura IV - Ordering Scheme | 7 V 1 D A B T 0 B E P C 00 0 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Bracket Actuator Lens Color Legend Legend Actuator Series Circuit Rating Termination Illumination Lamp Lamp Orientation Lens Legend 1 SERIES 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC 2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V 2 - - 5 2 - - 5 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 1 8 FLUSH BRACKET COLOR , PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 Black White Gray 1 A ON NONE OFF No Seal B W G 2 B (ON) NONE OFF One Seal C Y H 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 9 ACTUATOR 1,4 7 K ON OFF (ON) 0 No Actuator 8 L (ON) OFF (ON) E Contura IV, left orientation SPECIAL CIRCUITS T Contura IV, left orientation, laser etched H* 2 & 3 2 & 3, 5 & 4 5 & 4 F Contura IV, right orientation G* 2 & 3, 5 & 6 2 & 3 OFF R Contura IV, right orientation, laser etched S* 2 & 3, 5 & 6 2 & 3 1 & 2 3,6 Actuator orientation over terminals: M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 E* 5 & 6 5 & 3 5 & 1 10 LENS 0 - No Actuator Z - No Lens *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in Clear White Amber Green Red Blue selection 4. External jumper between terminals 2 & 4 for circuit E are 1 6 8 G M T provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 2 7 C H N U 3 8 D J P V 4 3 RATING 4 9 E K R W 1 .4VA @ 28VDC Resistive 5 A F L S Y B 15A 24V E F C 20A 18V Lens color for LEDs must be clear, white, or match color of LED. D 20A 12V Green or blue lenses are not recommended with Neon lamps. E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) 1,5,6 M .4VA/20A 12V 11 ACTUATOR COLOR N .4VA/15A 24V No Actuator 0 Black C Gray H Red S White Y Nickel D Pewter E 4 TERMINATION / BASE STYLE 8 term 10 Term Termination Jumper 2 12 ACTUATOR LENS OR BODY LEGENDS 1 2 .250 TAB (QC) no barriers No 11 ON 12 OFF 13 I 14 O A B .250 TAB (QC) with barriers No OFF ON O I J K .250 TAB (QC) no barriers Yes T2 to 5 3 5 Solder Lug no barriers No 15 O O 16 O O 17 O I 18 I O C D Solder Lug No F N N F 5 6 Wire Leads no barriers No F F E F Wire Leads No For additional legend options & codes, visit us at www.carlingtech.com. Note: Codes J & K for circuits H, G & M. Do not use silicone based lubricants to reduce terminal insertion forces during connector assembly, as it is detrimental to function and performance. 13 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) 1 Orientation 1 2 Orientation 2 5 ILLUMINATION & SWITCH SEALING 3 Orientation 3 Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 4 Orientation 4 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only 1 2 3 4 Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) 14 ACTUATOR LENS LEGEND B 2 1 DOWN 3 (+) 7 (–) 00 No legend this location / no actuator C 3 2 UP 3 (+) 7 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch D 4 1 DOWN 3 (+) 7 (–) requires two legends. If the two legends consist of one lens and one 2 DOWN 1 (+) 7 (–) body legend, lens legend must be specified in selection 12; body legend E 5 1 UP 1 (+) 7 (–) specified in selection 14. 2 UP 3 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) Notes: G 7 1 INDEPENDENT 8 (+) 7 (–) Consult factory to verify horsepower rating for your particular circuit choice. 2 UP 3 (+) 7 (–) 1 Custom colors are available. Consult factory. H Z 2 INDEPENDENT 8 (+) 7 (–) 2 White imprinting is standard on black actuators; Black imprinting is standard on white, U Y 1 INDEPENDENT 8 (+) 7 (–) red and gray actuators. Custom colors are available, consult factory. 2 INDEPENDENT 10 (+) 9 (–) 3 Gloss brow is on left side of E actuator and right side of F actuator. SINGLE POLE SWITCHES ONLY 4 Additional ratings available. See V-Series Switch Accessories page. J 8 1 DOWN 3 (+) 8 (–) 5 Laser etched rocker only available with lens code Z & actuator colors black, 2 INDEPENDENT 6 (+) 7 (–) nickel or pewter. K W 1 INDEPENDENT 8 (+) 7 (–) 6 Pewter and nickel colors only available with laser etched actuator. 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L 9 1 DOWN 3 (+) 6 (–) M R 1 UP 3 (+) 6 (–) N T 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) P V 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 8 V-Series Contura Sealed Rocker Switches - Contura V - Ordering Scheme V 1 D A B T 0 B G P C 00 0 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Bracket Actuator Lens Color Legend Legend Actuator Series Circuit Rating Termination Illumination Lamp Lamp Orientation Lens Legend 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) 1 SERIES Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V * Consult factory for “daylight bright” LED options. Typical current draw for 2 - - 5 2 - - 5 LED is 20ma. 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 1 8 FLUSH BRACKET COLOR , PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 Black White Gray 1 A ON NONE OFF No Seal B W G 2 B (ON) NONE OFF One Seal C Y H 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 9 ACTUATOR 7 K ON OFF (ON) 0 No Actuator 8 L (ON) OFF (ON) G Contura V SPECIAL CIRCUITS P Contura V, laser etched H* 2 & 3 2 & 3, 5 & 4 5 & 4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1 & 2 10 Lens M* (2 & 3, 5 & 6) 2 & 3 OFF 0 - No Actuator Z - No Lens style & location: #1 / #2 R* (2 & 3, 5 & 6) 2 & 3 2 & 1 Clear White Amber Green Red Blue E* 5 & 6 5 & 3 5 & 1 1 6 8 G M T bar *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in 2 7 C H N U bar/bar selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 8 D J P V oval 4 9 E K R W oval/bar 5 A F L S Y oval/oval 4 3 RATING Lens color for LEDs must be clear, white, or match color of LED. 1 .4VA @ 28VDC Resistive Green or blue lenses are not recommended with Neon lamps. B 15A 24V C 20A 18V D 20A 12V 1,3,5 11 ACTUATOR COLOR E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) No Actuator 0 Black C Gray H Red S F 10A 14V, 6A 14VT (circuit G only) White Y Nickel D Pewter E M .4VA/20A 12V N .4VA/15A 24V 2,6 12 ACTUATOR LENS OR BODY LEGENDS 11 ON 12 OFF 13 I 14 O 4 TERMINATION / BASE STYLE 8 term 10 Term Termination Jumper OFF ON O I 1 2 .250 TAB (QC) no barriers No 15 O O 16 O O 17 O I 18 I O A B .250 TAB (QC) with barriers No F N N F J K .250 TAB (QC) no barriers Yes T2 to 5 F F 3 5 Solder Lug no barriers No C D Solder Lug No For additional legend options & codes, visit us at www.carlingtech.com. 5 6 Wire Leads no barriers No E F Wire Leads No Note: Codes J & K for circuits H, G & M. Do not use silicone based 13 LEGEND ORIENTATION 0 No legend (used with codes 11-18 in selection 12) lubricants to reduce terminal insertion forces during connector assembly, 1 Orientation 1 as it is detrimental to function and performance. 2 Orientation 2 3 Orientation 3 4 Orientation 4 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only 1 2 3 4 Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) 14 ACTUATOR LENS LEGEND B 2 1 DOWN 3 (+) 7 (–) 00 No legend this location / no actuator C 3 2 UP 3 (+) 7 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch D 4 1 DOWN 3 (+) 7 (–) requires two legends. If the two legends consist of one lens and one 2 DOWN 1 (+) 7 (–) body legend, lens legend must be specified in selection 12; body legend E 5 1 UP 1 (+) 7 (–) specified in selection 14. 2 UP 3 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) Notes: G 7 1 INDEPENDENT 8 (+) 7 (–) Consult factory to verify horsepower rating for your particular circuit choice. 2 UP 3 (+) 7 (–) 1 Custom colors are available. Consult factory. H Z 2 INDEPENDENT 8 (+) 7 (–) 2 White imprinting is standard on black actuators; Black imprinting is standard on U Y 1 INDEPENDENT 8 (+) 7 (–) white, red and gray actuators. Custom colors are available, consult factory. 2 INDEPENDENT 10 (+) 9 (–) 3 Laser Etched rocker only available with lens code Z & actuator colors black, SINGLE POLE SWITCHES ONLY nickel or pewter. J 8 1 DOWN 3 (+) 8 (–) 4 Additional ratings available. See V-Series Switch Accessories page. 2 INDEPENDENT 6 (+) 7 (–) 5 Nickel and Pewter colors only available with laser etched actuator. K W 1 INDEPENDENT 8 (+) 7 (–) 6 Consult factory for laser etched lens callout. 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY L 9 1 DOWN 3 (+) 6 (–) M R 1 UP 3 (+) 6 (–) N T 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) P V 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com V-Series Contura Sealed Rocker Switches - Contura IV & V Locking - Ordering Scheme | 9 V 1 D A S W 0 B J Z E 00 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Bracket Actuator Lens Function Legend Legend Series Circuit Rating Termination Illumination Lock Lamp Orientation 1 SERIES 7 LAMP V Lamp above terminals 3 & 6 end of switch No lamp 0 Neon 1 125VAC 2 250VAC 3 Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V * Consult factory for “daylight bright” LED options. Typical current draw for 2 - - 5 2 - - 5 LED is 20ma. 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 1 8 FLUSH BRACKET COLOR , PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 Black White Gray 1 A ON NONE OFF No Seal B W G 4 D ON NONE ON One Seal C Y H 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) 9 HARD SURFACE ACTUATOR 9 N OFF NONE ON CONTURA IV: Orientation Black Gray Red White Left J K L M 4 3 RATING Right N P R S 1 .4VA @ 28VDC Resistive B 15A 24V Actuator orientation over terminals: 3,6 1,4 CONTURA V: C 20A 18V Orientation Black Gray Red White D 20A 12V U V W Y E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) Actuator orientation over terminals: 3,6 1,4 M .4VA/20A 12V N .4VA/15A 24V 5 10 LENS 4 TERMINATION / BASE STYLE Z - No Lens 8 term 10 Term Termination Jumper Clear White Amber Green Red Blue 1 2 .250 TAB (QC) no barriers No A B C D E F bar lens A B .250 TAB (QC) with barriers No G H J K L M oval lens J K .250 TAB (QC) no barriers Yes T2 to 5 3 5 Solder Lug no barriers No Lens color for LEDs must be clear, white, or match color of LED. C D Solder Lug No Green or blue lenses are not recommended with Neon lamps. 5 6 Wire Leads no barriers No E F Wire Leads No Note: Codes J & K for circuits H, G & M. Do not use silicone based 1 11 ACTUATOR LOCK FUNCTION AND COLOR lubricants to reduce terminal insertion forces during connector assembly, 3 Lock Color Up Down Up & Down Center as it is detrimental to function and performance. Match Actuator A H R 1 Black B J S 2 White C K T 3 5 ILLUMINATION & SWITCH SEALING Red D L V 4 Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED Safety Orange E M W 5 lamps only Gray F G N 6 Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – C 3 2 UP 3 (+) 7 (–) 2 12 ACTUATOR LENS OR BODY LEGEND H Z 2 INDEPENDENT 8 (+) 7 (–) 00 - No Legend DOUBLE POLE SWITCHES ONLY 21 22 23 24 M R 1 UP 3 (+) 6 (–) OFF ON O I 25 O 26 O 27 O 28 I 6 LOCK F N Lock above terminals 1 & 4 end of switch. F 6 W low profile lock Y high profile lock For additional legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 13 LEGEND ORIENTATION 1 Custom colors are available. Consult factory. 0 No legend 2 White imprinting is standard on black actuators; Black imprinting is standard on white, 1 Orientation 1 red and gray actuators. Custom colors are available, consult factory. 2 Orientation 2 3 Only available with 3 position circuits. Center OFF and special circuits only available 3 Orientation 3 with center position lock function. 4 Orientation 4 4 Additional ratings available. See V-Series Switch Accessories page. 5 Located at T3-6 end of switch. 1 2 3 4 6 Contura V style only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 10 V-Series Contura Sealed Rocker Switches - Contura VI WAVE - Ordering Scheme V 1 D B G N T B H A 7 C B AC 1 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Lens Color Insert Actuator Legend Actuator Color Lens Orientation Lens Legend 1 SERIES 6,7 LAMP V Lamp above terminals 3 & 6 end of switch No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V * Consult factory for “daylight bright” LED options. Typical current draw for 2 - - 5 2 - - 5 LED is 20ma. 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 1 8 FLUSH BRACKET COLOR , PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 Black White Gray 1 A ON NONE OFF No Seal B W G 2 B (ON) NONE OFF One Seal C Y H 3 C ON NONE (OFF) 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 9 ACTUATOR 7 K ON OFF (ON) 0 No Actuator H High Insert L Low Insert 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5 & 4 10,11 LENS G* 2 & 3, 5 & 6 2 & 3 OFF 0 - No Actuator Z - No Lens S* 2 & 3, 5 & 6 2 & 3 1 & 2 Clear White Amber Green Red Blue M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 – 7 C H N U Bar Lens Translucent E* 5 & 6 5 & 3 5 & 1 3 – D J P V Bar Lens Transparent *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in 4 – E K R W Oval Lens Transparent selection 4. External jumper between terminals 2 & 4 for circuit E are – A F L S Y Oval Lens Translucent provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 3 3 RATING 1 .4VA @ 28VDC Resistive B 15A 24V 12 ACTUATOR COLOR C 20A 18V C Black H Gray S Red Y White D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) 13 INSERT COLOR N Bright Nickel Plated M .4VA/20A 12V B Black S Satin Chrome Plated N .4VA/15A 24V C Bright Chrome Plated T Satin Nickel Plated D Satin Chrome Painted W White 4 TERMINATION / BASE STYLE 8 term 10 Term Termination Jumper 2 1 2 .250 TAB (QC) no barriers No 14 ACTUATOR LENS OR BODY LEGENDS A B .250 TAB (QC) with barriers No 00 - No Legend this location/No actuator J K .250 TAB (QC) no barriers Yes T2 to 5 11 ON 12 OFF 13 I 14 O 3 5 Solder Lug no barriers No OFF ON O I C D Solder Lug No 5 6 Wire Leads no barriers No 15 O O 16 O O 17 O I 18 I O E F Wire Leads No F N N F Note: Codes J & K for circuits H, G & M. Do not use silicone based F F lubricants to reduce terminal insertion forces during connector assembly, For additional legend options & codes, visit us at www.carlingtech.com. as it is detrimental to function and performance. 15 LEGEND ORIENTATION 5 ILLUMINATION & SWITCH SEALING 0 No legend (used with codes 11-18 in selection 12) Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 1 Orientation 1 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED 2 Orientation 2 lamps only 3 Orientation 3 Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 4 Orientation 4 S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) 1 2 3 4 D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) 16 ACTUATOR LENS LEGEND F 6 1 INDEPENDENT 8 (+) 7 (–) 00 No legend this location / no actuator 2 UP 3 (+) 6 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch G 7 1 INDEPENDENT 8 (+) 7 (–) requires two legends. If the two legends consist of one lens and one 2 UP 3 (+) 7 (–) body legend, lens legend must be specified in selection 12; body legend H Z 2 INDEPENDENT 8 (+) 7 (–) specified in selection 14. U Y 1 INDEPENDENT 8 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. 2 INDEPENDENT 10 (+) 9 (–) Notes: SINGLE POLE SWITCHES ONLY Consult factory to verify horsepower rating for your particular circuit choice. J 8 1 DOWN 3 (+) 8 (–) 1 Custom colors are available. Consult factory. 2 INDEPENDENT 6 (+) 7 (–) 2 White imprinting is standard on black actuators. Black imprinting is standard on white, K W 1 INDEPENDENT 8 (+) 7 (–) red and gray actuators. Custom colors are available, consult factory. 2 INDEPENDENT 6 (+) 7 (–) 3 Additional ratings available. See V-Series Switch Accessories page. DOUBLE POLE SWITCHES ONLY L 9 1 DOWN 3 (+) 6 (–) M R 1 UP 3 (+) 6 (–) N T 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) P V 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com V-Series Contura Sealed Rocker Switches - Contura VII - Ordering Scheme | 11 V 1 D A B T 0 B Z R C 00 0 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Color Legend Legend Actuator Orientation Lens Legend 6,7 LAMP (same coding for both selections) 1 SERIES Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V * Consult factory for “daylight bright” LED options. Typical current draw for 2 - - 5 2 - - 5 LED is 20ma. 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 1 8 FLUSH BRACKET COLOR , PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 Black White Gray ACTUATOR 1 A ON NONE OFF No Seal B W G ORENTATION 2 B (ON) NONE OFF ACTUATOR ABOVE TERMINALS One Seal C Y H 3 C ON NONE (OFF) ORENTATION 3,6 1,4 4 D ON NONE ON ABOVE TERMINALS 5 F ON NONE (ON) 3,6 1,4 9 ACTUATOR 6 J ON OFF ON STANDARD 0 No Actuator 7 K ON OFF (ON) STANDARD Z Contura VII 8 L (ON) OFF (ON) SPECIAL CIRCUITS Actuator orientation over terminals: 3,6 1,4 H* 2 & 3 2 & 3, 5 & 4 5 & 4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1 & 2 10 LENS M* (2 & 3, 5 & 6) 2 & 3 OFF Lens color for LEDs must be clear, white, or match color of LED. R* (2 & 3, 5 & 6) 2 & 3 2 & 1 Green or blue lenses are not recommended with Neon lamps. E* 5 & 6 5 & 3 5 & 1 0 - No Actuator Z - No Lens *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in White Amber Green Red Blue Lens style & location selection 4. External jumper between terminals 2 & 4 for circuit E are 6 B G M T provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 7 C H N U 4 8 D J P V 3 RATING 1 .4VA @ 28VDC Resistive 9 E K R W B 15A 24V C 20A 18V A F L S Y D 20A 12V 1 2 3 4 5 E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 1 11 ACTUATOR COLOR / THUMB PRINT COLOR O N/A - No Actuator C Black/Black H Grey/Black S Red/Black 4 TERMINATION / BASE STYLE Y White/Black 8 term 10 Term Termination Jumper 1 2 .250 TAB (QC) no barriers No A B .250 TAB (QC) with barriers No 2 12 ACTUATOR LENS OR BODY LEGENDS J K .250 TAB (QC) no barriers Yes T2 to 5 11 ON 12 OFF 13 I 14 O 3 5 Solder Lug no barriers No C D Solder Lug No OFF ON O I 5 6 Wire Leads no barriers No 15 O O 16 O O 17 O I 18 I O E F Wire Leads No F N N F Note: Codes J & K for circuits H, G & M. Do not use silicone based F F lubricants to reduce terminal insertion forces during connector assembly, For additional legend options & codes, visit us at www.carlingtech.com. as it is detrimental to function and performance. 13 LEGEND ORIENTATION 5 ILLUMINATION & SWITCH SEALING 0 No legend (used with codes 11-18 in selection 12) Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 1 Orientation 1 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED 2 Orientation 2 lamps only 3 Orientation 3 Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 4 Orientation 4 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) 1 2 3 4 D 4 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 5 1 UP 1 (+) 7 (–) 14 ACTUATOR LENS LEGEND 2 UP 3 (+) 7 (–) 00 No legend this location / no actuator F 6 1 INDEPENDENT 8 (+) 7 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch 2 UP 3 (+) 6 (–) requires two legends. If the two legends consist of one lens and one G 7 1 INDEPENDENT 8 (+) 7 (–) body legend, lens legend must be specified in selection 12; body legend 2 UP 3 (+) 7 (–) specified in selection 14. H Z 2 INDEPENDENT 8 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) Notes: SINGLE POLE SWITCHES ONLY Consult factory to verify horsepower rating for your particular circuit choice. J 8 1 DOWN 3 (+) 8 (–) 1 Custom colors are available. Consult factory. 2 INDEPENDENT 6 (+) 7 (–) 2 White imprinting is standard on black actuators. Black imprinting is standard on white, K W 1 INDEPENDENT 8 (+) 7 (–) red and gray actuators. Custom colors are available, consult factory. 3 Additional ratings available. See V-Series Switch Accessories page. 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY 4 Legends available for lighted oval lens version only L 9 1 DOWN 3 (+) 6 (–) M R 1 UP 3 (+) 6 (–) N T 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) P V 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 1 2 3 4 1 2 3 4 | 12 V-Series Contura Sealed Rocker Switches - Contura X, XI & XII - Ordering Scheme V 1 D A B 6 0 1 6 P Z 00 0 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Lens Legend Legend Actuator Orientation Lens Legend 1 SERIES 6,7 LAMP (same coding for both selections) V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 No lamp 0 Neon 1 125VAC 2 250VAC 2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V Terminal Connections as viewed ( ) - momentary LED* superbright superbright from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V 2 - - 5 2 - - 5 *Consult factory for “daylight bright” LED. Typical current draw for LED is 20ma 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 1 ( SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 8 BRACKET COLOR , PANEL SEAL EXTERNAL FOAM GASKET) 1 A ON NONE OFF X & XI with Flush Bracket X, XI, XII with Raised Bracket 2 B (ON) NONE OFF # of gaskets 0 1 2 0 1 3 C ON NONE (OFF) Black B C D 1 4 4 D ON NONE ON White W Y Z 2 5 5 F ON NONE (ON) 6 J ON OFF ON Gray G H J 3 6 7 K ON OFF (ON) 8 L (ON) OFF (ON) SPECIAL CIRCUITS 9 ACTUATOR H* 2 & 3 2 & 3, 5 & 4 5 & 4 No Actuator 0 G* 2 & 3, 5 & 6 2 & 3 OFF Black Gray White Red S* 2 & 3, 5 & 6 2 & 3 1 & 2 Contura X 1 2 3 4 M* (2 & 3, 5 & 6) 2 & 3 OFF Contura XI 6 7 8 9 R* (2 & 3, 5 & 6) 2 & 3 2 & 1 E* 5 & 6 5 & 3 5 & 1 Contura XII J K N M Actuator orientation over terminals: 3,6 1,4 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 1,4 10 LENS - ABOVE LAMP #1 TERMINALS 3,6 11 LENS - ABOVE LAMP #2 TERMINALS 4 0 - No Actuator Z - No Lens 3 RATING Clear White Amber Green Red Blue Lens Style 1 .4VA @ 28VDC Resistive 3 8 D J P V Bar B 15A 24V 4 9 E K R W One piece Square C 20A 18V 5 A F L S Y Two piece Square* D 20A 12V (With clear top protective lens) E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 2 7 C H N U Two piece Square* F 10A 14V, 6A 14VT (circuit G only) (With smoke top protective lens) M .4VA/20A 12V N .4VA/15A 24V 1 6 B G M T Two piece Square* (With white top protective lens) * All bottom lenses are molded of opaque material. Consult factory for 4 TERMINATION / BASE STYLE other lens colors. Lens color for LEDs must be clear, white, or match color 8 term 10 Term Termination Jumper of LED. Green or blue lenses are not recommended with Neon lamps. 1 2 .250 TAB (QC) no barriers No A B .250 TAB (QC) with barriers No 2 J K .250 TAB (QC) no barriers Yes T2 to 5 12 ACTUATOR LENS OR BODY LEGEND 3 5 Solder Lug no barriers No 00 - No Legend this location / No actuator C D Solder Lug No 11 ON 12 OFF 13 I 14 O 5 6 Wire Leads no barriers No OFF ON O I E F Wire Leads No 15 O O 16 O O 17 O I 18 I O Note: Codes J & K for circuits H, G & M. Do not use silicone based F N N F lubricants to reduce terminal insertion forces during connector assembly, F F as it is detrimental to function and performance. 21 22 23 24 OFF ON O I 5 ILLUMINATION & SWITCH SEALING 25 O 26 O 27 O 28 I Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals F N 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED F lamps only For additional legend options & codes, visit us at www.carlingtech.com. Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) 3 13 LEGEND ORIENTATION B 2 1 DOWN 3 (+) 7 (–) 0 No legend (used with codes 11-18 in selection 12) C 3 2 UP 3 (+) 7 (–) D 4 1 DOWN 3 (+) 7 (–) 1 Orientation 1 2 DOWN 1 (+) 7 (–) 2 Orientation 2 E 5 1 UP 1 (+) 7 (–) 3 Orientation 3 2 UP 3 (+) 7 (–) 4 Orientation 4 F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) 1 2 3 4 G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) 14 ACTUATOR LENS LEGEND SINGLE POLE SWITCHES ONLY 00 No legend this location / no actuator J 8 1 DOWN 3 (+) 8 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch requires two legends. If the two legends consist of one lens and one 2 INDEPENDENT 6 (+) 7 (–) body legend, lens legend must be specified in selection 12; body legend K W 1 INDEPENDENT 8 (+) 7 (–) specified in selection 14. 2 INDEPENDENT 6 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. DOUBLE POLE SWITCHES ONLY L 9 1 DOWN 3 (+) 6 (–) Notes: M R 1 UP 3 (+) 6 (–) Consult factory to verify horsepower rating for your particular circuit choice. N T 1 DOWN 3 (+) 6 (–) 1 Custom colors are available. Consult factory. 2 DOWN 1 (+) 4 (–) 2 White imprinting is standard on black actuators; Black imprinting is standard on white, P V 1 UP 1 (+) 4 (–) red & gray actuators. Custom colors are available, consult factory. 2 UP 3 (+) 6 (–) 3 With 2 square lenses, use selection 12 for lens above lamp 1, & selection 14 for lens above lamp 2. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Not available with Contura XI rockers. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com V-Series Contura Sealed Rocker Switches - Contura X Locking - Ordering Scheme | 13 V 1 D A S W 0 1 1 P B 00 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Series Circuit Rating Termination Illumination Lock Lamp Bracket Actuator Lens Function Legend Legend Orientation 1 SERIES 6,7 LAMP (same coding for both selections) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V * Consult factory for “daylight bright” LED options. Typical current draw for 2 - - 5 2 - - 5 LED is 20ma. 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 1 8 FLUSH BRACKET COLOR , PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 Black White Gray 1 A ON NONE OFF No Gasket 1 2 3 4 D ON NONE ON 6 J ON OFF ON One Gasket 4 5 6 9 N OFF NONE ON SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5 & 4 9 HARD SURFACE ACTUATOR G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1 & 2 Contura X Black Gray Red White E* 5 & 6 5 & 3 5 & 1 1 2 3 4 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in Actuator orientation over terminals: 3,6 1,4 selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 5 10 LENS - ABOVE LAMP #2 TERMINALS Z - No Lens 4 3 RATING Clear White Amber Green Red Blue Lens Style 1 .4VA @ 28VDC Resistive 3 8 D J P V Bar B 15A 24V 4 9 E K R W One piece Square C 20A 18V 5 A F L S Y Two piece Square* D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) (with clear top protective lens) F 10A 14V, 6A 14VT (circuit G only) 2 7 C H N U Two piece Square* M .4VA/20A 12V (with smoke top protective lens) N .4VA/15A 24V 1 6 B G M T Two piece Square* (with white top protective lens) 4 TERMINATION / BASE STYLE * All bottom lenses are molded of opaque material. Consult factory for 8 term 10 Term Termination Jumper other lens colors. 1 2 .250 TAB (QC) no barriers No Lens color for LEDs must be clear, white, or match color of LED. A B .250 TAB (QC) with barriers No Green or blue lenses are not recommended with Neon lamps. J K .250 TAB (QC) no barriers Yes T2 to 5 3 5 Solder Lug no barriers No C D Solder Lug No 3 11 ACTUATOR LOCK FUNCTION AND COLOR 5 6 Wire Leads no barriers No Lock Color Up Down Up & Down E F Wire Leads No Match Actuator A H R Note: Codes J & K for circuits H, G & M. Do not use silicone based Black B J S lubricants to reduce terminal insertion forces during connector assembly, White C K T as it is detrimental to function and performance. Red D L V Gray E M W Safety Orange F N Y 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 2 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED 12 ACTUATOR LENS OR BODY LEGEND lamps only 00 - No Legend Sealed Unsealed Lamps Illumination Type Lamp wired to Termi- 21 22 23 24 nals OFF ON O I S 0 NONE – – C 3 2 UP 3 (+) 7 (–) 25 O 26 O 27 O 28 I H Z 2 INDEPENDENT 8 (+) 7 (–) F N DOUBLE POLE SWITCHES ONLY F M R 1 UP 3 (+) 6 (–) For additional legend options & codes, visit us at www.carlingtech.com. 6 LOCK 3 13 LEGEND ORIENTATION Lock above terminals 1 & 4 end of switch. 0 No legend (used with codes 11-18 in selection 12) W Lock 1 Orientation 1 2 Orientation 2 Notes: 3 Orientation 3 Consult factory to verify horsepower rating for your particular circuit choice. 4 Orientation 4 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators; Custom colors are available, consult factory. 3 Located over T1-4 end of switch. 1 2 3 4 4 Additional ratings available. See V-Series Switch Accessories page. 5 Located over T3-6 end of switch. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 14 V-Series Contura Sealed Rocker Switches - Contura XIV - Ordering Scheme V 1 D B B C 0 B FA P C AB 1 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Actuator Legend Legend Actuator, Color Orientation Lens Legends 1 SERIES 6 & 7 LAMP No lamp 0 V Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbright superbright 2 CIRCUIT Red Amber Green Red Terminal Connections as viewed ( ) - momentary 2VDC A L F R from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 6VDC B M G S 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 12VDC C N H T 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 24VDC D P J V 1 - - 4 1 - - 4 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 2 - - 5 2 - - 5 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 8 BRACKET COLOR & PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 Color No Gasket 1 Gasket 2 Gasket 1 A ON NONE OFF Black B C D 2 B (ON) NONE OFF Gray G H J 3 C ON NONE (OFF) White W Y Z 4 D ON NONE ON 5 F ON NONE (ON) 6 J ON OFF ON 9 ACTUATOR STYLE 7 K ON OFF (ON) 0 No Actuator - Furnished separately 8 L (ON) OFF (ON) FA Contura XIV SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5 & 4 FB Contura XIV - Laser Etched G* 2 & 3, 5 & 6 2 & 3 OFF M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 10 LENS COLOR / STYLE E* 5 & 6 5 & 3 5 & 1 0 - No Actuator Z - No Lens S* 2 & 3, 5 & 6 2 & 3 1 & 2 Clear White Amber Green Red Blue *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are 1 6 B G M T provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 2 7 C H N U 3 8 D J P V 3 4 9 E K R W 3 RATING 1 .4VA @ 28VDC Resistive 5 A F L S Y B 15A 24V 5 A N/A N/A N/A N/A Laser-Etched Actuator Only C 20A 18V Lens color for LEDs must be clear, white, or match color of LED. D 20A 12V Green or blue lenses are not recommended with Neon lamps. E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) 1 11 ACTUATOR COLOR 4 TERMINATION / BASE STYLE O N/A - No Actuator C Black 8 Term 10 Term Termination Jumper 1 2 .250 TAB (QC) no barriers No S Red Y White A B .250 TAB (QC) with barriers No J K .250 TAB (QC) no barriers Yes T2 to 5 3 4 Solder Lug no barriers No 2 C D Solder Lug No 12 ACTUATOR LENS or BODY LEGEND 5 6 Wire Leads no barriers No 00 - No Legend this location / No actuator E F Wire Leads No 11 ON 12 OFF 13 I 14 O Note: Codes J & K for circuits H, G & M. Do not use silicone based OFF ON O I lubricants to reduce terminal insertion forces during connector assembly, 15 O O 16 O O 17 O I 18 I O as it is detrimental to function and performance. F N N F F F 5 ILLUMINATION Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 13 LEGEND ORIENTATION 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED 0 No legend lamps only 1 Orientation 1 Lamps Illumination Type Lamp wired to Terminals 2 Orientation 2 S NONE – – 3 Orientation 3 A 1 INDEPENDENT 8 (+) 7 (–) 4 Orientation 4 B 1 DOWN 3 (+) 7 (–) 1 24 3 C 2 UP 3 (+) 7 (–) D 1 DOWN 3 (+) 7 (–) 2 DOWN 1 (+) 7 (–) E 1 UP 1 (+) 7 (–) 14 ACTUATOR / LENS LEGEND 2 UP 3 (+) 7 (–) 00 No legend this location / no actuator F 1 INDEPENDENT 8 (+) 7 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch 2 UP 3 (+) 6 (–) requires two legends. If the two legends consist of one lens and one G 1 INDEPENDENT 8 (+) 7 (–) body legend, lens legend must be specified in selection 12; body legend 2 UP 3 (+) 7 (–) H 2 INDEPENDENT 8 (+) 7 (–) specified in selection 14. SINGLE POLE SWITCHES ONLY For legend options & codes, visit us at www.carlingtech.com. J 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) Notes: K 1 INDEPENDENT 8 (+) 7 (–) Consult factory to verify horsepower rating for your particular circuit choice. 2 INDEPENDENT 6 (+) 7 (–) 1 Custom colors are available. Consult factory. DOUBLE POLE SWITCHES ONLY 2 White imprinting is standard on black actuators; Black imprinting is L 1 DOWN 3 (+) 6 (–) standard on white, red and gray actuators. M 1 UP 3 (+) 6 (–) 3 Additional ratings available. See V-Series Switch Accessories page. N 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) P 1 UP 1 (+) 4 (–) 2 UP 3 (+) 6 (–) U 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | V-Series Contura Sealed Rocker Switches - Contura XIV Locking - Ordering Scheme 15 V 1 D A B W 0 B FC Z B 00 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Series Circuit Rating Termination Illumination Lock Lamp Bracket Actuator Lens Actuator Legend Legend Color Orientation 1 SERIES 7 LAMP V No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V 2 - - 5 2 - - 5 * Consult factory for “daylight bright” LED options. Typical current draw for 3 - - 6 3 - - 6 LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 8 BRACKET COLOR & PANEL SEAL 1 A ON NONE OFF Color No Gasket 1 Gasket 2 Gasket - B (ON) NONE OFF Black B C D 4 D ON NONE ON Gray G H J 6 J ON OFF ON White W Y Z 7 K ON OFF (ON) 8 L (ON) OFF (ON) 9 N OFF NONE ON 9 ACTUATOR COLOR / STYLE FC Black - Standard Rocker SPECIAL CIRCUITS FD Black - Laser Etched H* 2 & 3 2 & 3, 5 & 4 5 & 4 FS Red - Standard Rocker G* 2 & 3, 5 & 6 2 & 3 OFF FT Red - Laser Etched M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 E* 5 & 6 5 & 3 5 & 1 10 LENS COLOR / STYLE S* 2 & 3, 5 & 6 2 & 3 1 & 2 Z - No Lens *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in Clear White Amber Green Red Blue selection 4. External jumper between terminals 2 & 4 for circuit E are 1 6 B G M T provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 3 8 D J P V 5 A N/A N/A N/A N/A Laser-Etched Actuator Only 3 3 RATING Lens color for LEDs must be clear, white, or match color of LED. 1 .4VA @ 28VDC Resistive Green or blue lenses are not recommended with Neon lamps. B 15A 24V C 20A 18V D 20A 12V 1 11 ACTUATOR LOCK COLOR / FUNCTION E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) LOCK IN POSITION F 10A 14V, 6A 14VT (circuit G only) Lock Color UP DOWN UP & DOWN CENTER Match Actuator A H R 1 Black B J S 2 4 TERMINATION / BASE STYLE White C K T 3 8 Term 10 Term Termination Jumper Red D L V 4 1 2 .250 TAB (QC) no barriers No Orange E M W 5 A B .250 TAB (QC) with barriers No Gray F G N 6 J K .250 TAB (QC) no barriers Yes T2 to 5 Note: Codes J & K for circuits H, G & M. Do not use silicone based 2 12 ACTUATOR LENS or BODY LEGEND lubricants to reduce terminal insertion forces during connector assembly, as it is detrimental to function and performance. 00 - No Legend 21 22 23 24 OFF ON O I 5 ILLUMINATION 25 O 26 O 27 O 28 I Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals F N 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED F lamps only Lamps Illumination Type Lamp wired to Terminals S NONE – – C 2 UP 3 (+) 7 (–) 13 LEGEND ORIENTATION H 2 INDEPENDENT 8 (+) 7 (–) 0 No legend 1 Orientation 1 DOUBLE POLE SWITCHES ONLY 2 Orientation 2 M 1 UP 3 (+) 6 (–) 3 Orientation 3 4 Orientation 4 1 24 3 6 LOCK OPTION W Low Profile Lock Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. 3 Additional ratings available. See V-Series Switch Accessories page. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 16 V–Series Contura Sealed Rocker Switches - Contura II, III, & IV - Dimensional Specifications Dimensional Specifications: in. [mm] Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | V–Series Contura Sealed Rocker Switches - Contura V, VI & VII - Dimensional Specifications 17 Dimensional Specifications: in. [mm] CONTURA V CONTURA V CONTURA VI CONTURA VII SHOWN WITH SHOWN WITH OVAL SHOWN WITH LARGE LENS SHOWN WITH BAR LENS LENS AND BAR LENS LOW PROFILE LOCK 1.922 [48.56] 1.922 [48.82] 1.922 [48.56] .080[2.03] 1.950 [49.53] 1.079 1.126 [27.40] 1.479 [28.60] 1.550 [37.57] [39.37] 10 TERMINAL BASE 8 TERMINAL BASE 8 TERMINAL BASE W/BARRIER AND 10 TERMINAL BASE W/BARRIERS W/O BARRIERS LAMP TERMINAL W/O BARRIERS 1.020 1.020 0.985 1.000 [25.91] [25.91] [25.02] [25.40] .505 .505 [12.83] [12.83] .250 [6.35] .250 [6.35] .250 .250 X .031 [.78] [6.35] [6.35] .031 X X .031 [.78] .031 .820 [.78] .820 [.78] [20.83] [20.83] .820 .960 .390 [20.83] [24.38] .960 [9.90] [24.38] .960 .960 [24.38] [24.38] 8 TERMINAL BASE 8 TERMINAL BASE 10 TERMINAL BASE 10 TERMINAL BASE W/O BARRIERS W/BARRIERS W/O BARRIERS W/O BARRIERS 8 7 8 7 1 4 2.029 1 4 [51.53] 2 5 2 5 3 6 3 6 10 9 SWITCH SHOWN WITH BOTTOM VIEW BOTTOM VIEW VCH CONNECTOR 8 TERMINAL TERMINAL SWITCH SHOWN WITH TERMINAL ARRANGEMENT ARRANGEMENT VC1 CONNECTOR 10 SWITCH SHOWN 8 TERMINAL BASE 10 TERMINAL BASE TERMINAL WITH VC1 CONNECTOR 10 TERMINAL Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 18 V–Series Contura Sealed Rocker Switches - Contura X, XI, XII & XIV - Dimensional Specifications Dimensional Specifications: in. [mm] CONTURA X CONTURA XI CONTURA XII CONTURA XIV SHOWN WITH RAISED BRACKET SHOWN WITH RAISED SHOWN WITH PADDLE SHOWN WITH LARGE LENS BRACKET AND TWO SQUARE ACTUATOR LENSES 1.928 [48.97] .667 [16.94] .350 1.910 [48.51] 1.910 [48.51] .426 [10.82] [8.89] .573 1.305 [33.15] [14.56] .350 1.506 1.586 [8.89] [38.25] [40.28] 1.370 [34.79] 1.370 [34.79] 1.370 [34.79] 8 TERMINAL BASE 10 TERMINAL BASE 8 TERMINAL BASE 10 TERMINAL BASE W/BARRIERS W/O BARRIERS W/O BARRIERS W/O BARRIERS .960 [24.38] .970 [24.64] .960 [24.38] .960 [24.38] .780 [19.81] .780 [19.81] .780 [19.81] .250 [6.35] X .031[.78] .390 [9.90] .390 [9.90] .390 [9.90] .820 .820 [20.82] .820 [20.82] [20.83] .820 [20.82] .960 [24.38] 8 TERMINAL BASE 10 TERMINAL BASE 10 TERMINAL W/BARRIERS W/BARRIERS BASE W/O BARRIERS 8 7 8 7 1 4 1 4 2 5 2 5 3 6 3 6 10 9 BOTTOM VIEW BOTTOM VIEW SWITCH SHOWN WITH SWITCHES SHOWN WITH TERMINAL TERMINAL VCH CONNECTOR VC1 CONNECTOR ARRANGEMENT ARRANGEMENT 8 TERMINAL 10 TERMINAL 8 TERMINAL BASE 10 TERMINAL BASE Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | V-Series Contura Sealed Rocker Switches - II to XIV - Circuit Diagrams 19 Circuit Diagrams: CIRCUIT CIRCUIT CIRCUIT CIRCUIT DIAGRAM CIRCUIT DIAGRAM CIRCUIT DIAGRAM CODE CODE CODE 3 3 6 13 46 1 A J 2 25 25 3 3 6 1 3 4 6 2 B K 2 2 5 2 5 3 3 6 1 34 6 3 C L 2 2 5 2 5 1 3 1 3 4 6 3 6 4 D M 2 2 5 2 5 1 3 13 4 6 1 3 6 5 E R 2 25 2 5 13 1 3 4 6 13 6 6 F S 2 2 5 25 13 3 6 7 G SYMBOL LEGEND SYM. DEFINITION 2 2 5 DESIGNATES TERMINALS AND CONTACTS 1 3 3 4 DESIGNATES MAINTAINED CIRCUITS DESIGNATES OTHER POSITION DESIGNATES MOMENTARY CIRCUITS 8 H DESIGNATES TWO POSITION CONNECTION DESIGNATES EXTERNAL JUMPER PROVIDED 2 25 BY CUSTOMER Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 20 V-Series Contura Sealed Rocker Switches - II to XIV - Lamp Circuit Diagrams, Hazard Warning Circuit Diagrams Lamp Circuit Diagrams: LAMP CIRCUIT LAMP CIRCUIT LAMP CIRCUIT LAMP CIRCUIT CIRCUIT DIAGRAM CIRCUIT DIAGRAM CIRCUIT DIAGRAM CIRCUIT DIAGRAM CODE CODE CODE CODE +8 +8 +3 -6 +3 -6 +3 +6 1 1 2 1 SPECIAL 1 2 A / 1 F / 6 L / 9 #1 -7 -7 -7 +3 +8 +3 +3 -6 +8 +6 SPECIAL 1 1 2 2 1 2 B / 2 G / 7 M / R #3 -7 -7 -7 +3 +8 +1 +3 -4 -6 +8 +3 SPECIAL 1 2 2 2 1 2 C / 3 H / Z N / T #4 -7 -7 -7 +1 -8 +3 +6 +1 +3 -4 -6 +3 1 D / 4 2 J / 8 1 2 P / V 1 2 -7 -7 +8 +10 +1 +3 +8 +6 1 2 2 U / Y E / 5 1 K / W 1 2 -7 -9 -7 (-)7 J-Series Hazard Warning Circuit Diagrams: CIRCUIT CIRCUIT CIRCUIT DIAGRAM CIRCUIT DIAGRAM CODE CODE 13 17 18 10(-) 10(-) 1 3 17 18 J1 1 J5 2 2 2 5 58 8 2 5 8 11 11 11 11 13 13 13 13 3 3 3 3 14 17 18 10(-) 11 13 3 14 6 J2 1 JA 58 5 13 17 18 10(-) 11 13 3 14 J3 1 JJ NOTE: 2 5 8 J circuits are available for all non-locking V-Series styles. Consult factory for partnumber details. 13 17 18 10(-) 11 13 3 3 3 3 14 15 12 616 SYMBOL LEGEND 1 J4 JK SYM. DEFINITION DESIGNATES TERMINALS AND CONTACTS 2 5 DESIGNATES LAMP LOCATION Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | V-Series Contura Sealed Rocker Switches - Stand-Alone Components 21 Reduce inventory levels and cost by stocking actuators and base switches separately. Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes. Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes. Contura VI Actuator with lenses and inserts only: VV with code selections 9-16 Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes. Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes. Panel Seal: VPS Contura X & XI actuators without lenses separately: Contura XII actuators without lenses separately: VVR 6 1 00 1 VVP J 1 Z 21 1 00 1 2 3 4 5 1 2 3 4 5 6 7 Actuator Separately Actuator Lens Actuator Legend Actuator Style & Lens Lens Legend Legend Legend Style/Color Opening Legend Orientation Color Opening Opening Orientation 1 CONTURA X & XI ACTUATOR SEPARATELY 1 CONTURA XII ACTUATOR SEPARATELY VVR VVP 2 ACTUATOR STYLE & COLOR 2 ACTUATOR STYLE & COLOR Black Gray White Red J Black K Gray N White M Red Contura X 1 2 3 4 Contura XI 6 7 8 9 3,4 LENS OPENING FOR Z No lens 1 Bar lens 2 Square lens 1 3 LENS OPENING FOR 1 One bar lens 5 square lens on top/ 2 One bar lenses bar lens on bottom 2 5, 7 LENS OR BODY LEGEND 3 One square lens (Contura X only) 00 - No Legend 21 22 23 24 4 two square lens OFF ON O I 25 O 26 O 27 O 28 I 4 ACTUATOR LENS OR BODY LEGEND F N 00 - No Legend this location F 11 ON 12 OFF 13 I 14 O For additional legend options & codes, visit us at www.carlingtech.com. OFF ON O I 15 O O 16 O O 17 O I 18 I O F N N F 3 6 LEGEND ORIENTATION F F 0 No legend For additional legend options & codes, visit us at www.carlingtech.com. 1 Orientation 1 2 Orientation 2 1 2 1 5 LEGEND ORIENTATION 0 No legend Contura X, XI & XII actuator lens assembly separately: 1 Orientation 1 2 Orientation 2 3 Orientation 3 1 2 3 4 4 Orientation 4 VVL 2 1 00 0 1 2 3 4 5 Lens Separately Lens Lens Legend Legend Contura X, XI & XII top piece of 2-piece lens separately: Style Color Orientation 1 CONTURA X, XI & XII LENS SEPARATELY 1 TOP OF LENS SEPARATELY VVL VVT VVT 1 3 1 2 2 COLOR 2 LENS STYLE Lens Separately Color 1 Clear 2 Smoke 3 White 1 Bar lens 2 One Piece Square lens 5 3 Bottom of Two-Piece Square lens Contura X, XI & XII actuator lens assembly: 3 TRANSLUCENT LENS COLOR 4 4 1 Clear 2 White 3 Amber 4 Green 5 Red 6 Blue actuator stem top lens two piece 2 4 LENS OR BODY LEGEND } lens assembly posts mount toward actuator stem 00 - No Legend 21 22 23 24 bottom lens OFF ON O I 1 piece lens/bar lens are positioned the same as bottom lens for assembly, minus the top lens. Lenses snap in from bottom. 25 O 26 O 27 O 28 I F N Notes: F 1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2 For additional legend options & codes, visit us at www.carlingtech.com. must be chosen. 2 Center of actuator marking not available for Contura XII. 3 Legend is not available for bar style lens. 3 5 LEGEND ORIENTATION 4 Not recommended with neon lamps. 0 No legend 5 Must also order top piece of 2 piece square lens separately. 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 1 2 3 4 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 22 V-Series Contura Sealed Rocker Switches - Accessories Easily integrate Contura products into your system, with Contura Accessories Q.C. SELECTION GUIDE WIRE PART NO Contura Connectors RANGE COMPANY ORIEN- TIN 2 SERIES Q.C. SELECTION GUIDE PLAIN TATION AWG MM PLATED BRASS (REF) BRASS WIRE PART NO RANGE 02965580 12 3.0 COMPANY ORIEN- TIN 02965471 12010601 (2)16-14 (2)1.0-2.0 SERIES PLAIN 2 TATION Q.C. SELECTION GUIDE Q.C. SELECTION GUIDE Q.C. SELECTION GUIDE AWG MM PLATED PACKARD BRASS 02965470 16-14 1.0-2.0 B (REF) 58 SERIES BRASS WIRE WIRE WIRE PART NO PART NO PART NO 02965469 06288318 RANGE 20-18 RANGE .5-.8 RANGE 02965580 12 3.0 COMPANY COMPANY COMPANY ORIEN- ORIEN- ORIEN- TIN TIN TIN SERIES SERIES PLAIN SERIES PLAIN 12084590 PLAIN 102 TATION5.0 2 TATION 2 TATION 02965471 12010601 (2)16-14 (2)1.0-2.0 AWG MM AWG MM AWG MM PLATED PLATED PLATED BRASS BRASS BRASS TANG PACKARD BRASS 12052224 BRASS (REF) 1BRASS 2 (REF) 3.0 (REF) 02965470 16-14 1.0-2.0 B 58 SERIES 02965580 02965580 1202965580 3.012 3.012 3.0 12015870 16-14 1.0-2.0 02965469 06288318 20-18 .5-.8 PACKARD 02965471 12010601 02965471 (2)16-14 12010601 02965471 (2)1.0-2.0 (2)16-14 12010601 (2)1.0-2.0 (2)16-14 (2)1.0-2.0 METRI-PACK 12020035 (2)22-18 (2).5-.8 A PACKARD PACKARD PACKARD 12084590 10 5.0 Q.C. SELECTION GUIDE 02965470 02965470 16-14 02965470 1.0-2.0 16-14 B 1.0-2.0 16-14 B 1.0-2.0 B 58 SERIES 630 SERIES58 SERIES 58 SERIES TANG 1201583212052224 12015869 12 20-18 3.0 .5-.8 02965469 06288318 02965469 20-18 06288318 02965469 .5-.8 20-18 06288318 .5-.8 20-18 .5-.8 WIRE PART NO RANGE 12015870 12052222 16-14 20-22 1.0-2.0 .35-.5 12084590 12084590 10 5.012084590 10 5.010 5.0 PACKARD COMPANY ORIEN- TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT TIN TANG TANG TANG 12052224 12052224 12 3.012052224 12 3.012 3.0 SERIES PLAIN 2 TATION METRI-PACK 12020035 (2)22-1816-12 (2).5-.8 1.3-3 A AWG MM Q.C. SELECTION GUIDE PLATED SYMBOL 60253-1 BRASS 60253-2 630 SERIES 12015870 16-14 12015870 1.0-2.0 16-14 12015870 1.0-2.0 16-14 1.0-2.0 AMP (REF) BRASS PACKARD PACKARD 12015832 PACKARD 12015869 20-18 .5-.8 (2) 16 (2) 1.3 WIRE METRI- 250 SERIES PACK METRI-PACK 12020035 METRI-PACK (2)22-18 12020035 (2).5-.8 (2)22-18 12020035 A (2).5-.8 (2)22-18 A (2).5-.8 A 02965580 PART NO 12 3.0 B RANGE 630 SERIES 630 SERIES 630 SERIES 12052222 20-22 .35-.5 FASTIN-FASTON 42100-1 42100-2 18-14 .8-2 12015832 12015869 12015832 20-18 12015869 12015832 .5-.8 20-18 12015869 .5-.8 20-18 .5-.8 COMPANY 02965471 12010601 (2)16-14 (2)1.0-2.0 ORIEN- TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT TIN P SERIES ACKARD PLAIN 16-12 1.3-3 2 TATION 60295-1 02965470 12052222 60295-2 20-22 12052222 A 16-14 WG .35-.5 22-18 20-22 12052222 1.0-2.0 MM .35-.5 20-22 .3-.9 B .35-.5 PLATED SYMBOL 58 SERIES 60253-1 60253-2 TANG SYMBOL =TANG SYMBO SHOWS ORIEN L =TANG SYMBO TA SHOWS ORIEN TION OF L = TANG IN SLOT TA SHOWS ORIEN TION OF TANG IN SLOT TATION OF TANG IN SLOT BRASS AMP 02965469 06288318 BRASS 20-18 .5-.8 (REF) 16-12 (2) 16 1.3-3 16-12 (2) 1.31.3-3 16-12 1.3-3 SYMBOL SYMBOL SYMBOL 250 SERIES 60253-1 60253-2 60253-1 60253-2 60253-1 60253-2 AMP AMP AMP NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availabilit B y. 02965580 12 3.0 12084590 (2) 16 10(2) 1.3 (2) 16 5.0 (2) 1.3 (2) 16 (2) 1.3 FASTIN- 250 SERIES FASTON 250 SERIES 42100-1 250 SERIES 42100-2 18-14 .8-2 AMP is a registered trademark of AMP Inc. Harrisburg, PA B B TANG B 02965471 12010601 12052224 (2)16-14 12 (2)1.0-2.0 3.0 FASTIN-FASTONFASTIN- 42100-1 FASTON FASTIN- 42100-2 42100-1 FASTON 18-14 42100-2 42100-1 .8-2 18-14 42100-2 .8-2 18-14 .8-2 Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems PACKARD 60295-1 60295-2 22-18 .3-.9 Warren, Ohio 02965470 12015870 16-14 16-14 1.0-2.0 1.0-2.0 B 58 SERIES PACKARD 60295-1 60295-2 60295-1 22-18 60295-2 60295-1 .3-.9 22-18 60295-2 .3-.9 22-18 .3-.9 METRI-PACK 02965469 06288318 12020035 (2)22-18 20-18 (2).5-.8 .5-.8 A NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability. NOTE: Consult Delphi Packard and/or 630 SERIES NOTE: Consult Delphi Packard and/or NOTE: Amp on actual part numbers and availabilit Consult Delphi Packard and/or Amp on actual part numbers and availabilit Amp on actual part numbers and availabilit y. y. .820[20.83] y. 12015832 12015869 20-18 .5-.8 12084590 10 5.0 AMP is a registered trademark of .820[20.83] AMP Inc. Harrisburg, PA AMP is a registered trademark of AMP is a registered trademark of AM AM P Inc. Harrisburg, P is a registered trademark of AMP P Inc. Harrisburg, A AMP PA Inc. Harrisburg, PA TANG 12052224 12052222 20-22 12 .35-.5 3.0 Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio Warren, Ohio Warren, Ohio Warren, Ohio TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT 12015870 16-14 16-12 1.0-2.0 1.3-3 PACKARD SYMBOL 60253-1 60253-2 AMP .820[20.83] .820[20.83] .820[20.83] METRI-PACK 12020035 (2)22-18 (2) 16 (2) 1.3 (2).5-.8 A .820[20.83] .820[20.83] .820[20.83] .820[20.83] 250 SERIES B 630 SERIES .820[20.83] FASTIN-FASTON 12015832 42100-1 12015869 42100-2 20-18 18-14 .8-2 .5-.8 .770[19.56] 60295-1 12052222 60295-2 20-22 22-18 .35-.5 .3-.9 TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT 16-12 1.3-3 NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability. SYMBOL 60253-1 60253-2 .770[19.56] .770[19.56] .770[19.56] AMP AMP is a registered trademark of AMP Inc. Harrisburg, (2) 16 PA (2) 1.3 250 SERIES B Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio .770[19.56] FASTIN-FASTON 42100-1 42100-2 18-14 .8-2 .920[23.37] .920[23.37] 1.170[29.72] 60295-1 60295-2 22-18 .3-.9 .820[20.83] .920[23.37] .820[20.83] .920[23.37] .920[23.37] .920[23.37] .920[23.37] .920[23.37] 1.170[29.72] 1.170[29.72] 1.170[29.72] NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability. A A A A AMP is a registered trademark of AMP Inc. Harrisburg, PA PACKARD 630 PACKARD 630 A .920[23.37] A A A A A .920[23.37] VC2 A A A A 1.170[29.72] A A PACKARD 630 Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems PACKARD 630 Warren, Ohio VC1 VC1 PACKARD 630 VC2 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 VC2 VC2 VC2 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 VC1 VC1 VC1 VC1 VC1 VC1 VC2 VC2 VC2 .770[19.56] .950[24.13] B B .950[24.13] .950[24.13] .950[24.13] B B B B B B .820[20.83] A .820[20.83] A A B A B AMP, PACKARD 58 AMP, PACKARD 58 AMP AMP B B B B B B AMP, PACKARD 58 AMP, PACKARD 58 AMP, PACKARD 58 AMP, PACKARD 58 AMP, PACKARD 58 AMP AMP, PACKARD 58 AMP AMP AMP AMP AMP AMP, PACKARD 58 AMP, PACKARD 58 PACKARD 630 AMP AM , PACKARD 58 P, PAM ACKARD 58 P, PACKARD 58 AMP, PACKARD 58 PACKARD 630 AMP, PACKARD 58 AMP, PACKARD 58 VC2 PACKARD 630 10 3 2 1 8 10 3 2 1784P1 ACKARD 630 053 62 9 1784 5 6 9 107 3 4 2 51 6 89 10 3 2 1 8 710 4 3 5 2 61 9 8 7 4 5 6 9 7 4 5 6 9 10 3 2 1 8 7 4 5 6 9 10 3 2 1 8 7 4 5 6 9 VC1 VC1 VC23 2 1 8 3 2 1 8 7 34 2 5 16 8 7 4 5 6 7 4 5 6 3 2 1 8 7 4 5 6 .920[23.37] .920[23.37] 1.170[29.72] .950[24.13] B B 1.266[32.16] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.466[37.24] 1.250[31.75] 1.250[31.75] 1.250[31.75] B B AMP, PACKARD 58 AMP, PACKARD 58 AMP AMP .770[19.56] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.250[31.75] AMP, PACKARD 58 AMP, PACKARD 58 A A A A 10 3 2 1 8 7 4 5 6 9 10 3 2 1 8 7 4 5 6 9 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 VC2 3 2 1 8 7 4 5 6 MARKING DETAIL MARKING DETMARKING DE AIL MARKING DE TAIL T MARKING DE AIL TAIL MARKING DE MARKING DE TAIL TAILMARKING DETAIL MARKING DE MARKING DET TAIL AIL MARKING DETAIL MARKING DE MARKING DE TAILTAIL MARKING DETAIL MARKING DE MARKING DE TAIL TAILMARKING DETAIL MARKING DETAIL VC1 VC1 VC2 FRONT VIEW B FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW B FRON REAR VIEW T VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRON REAR VIEW T VIEW .950[24.13] FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW REAR VIEW MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL B B 1.266[32.16] AMP, PACKARD 58 .920[23.37] 1.466[37.24] AMP, PACKARD 58 AMP 1.266[32.16] .920[23.37] AMP 1.466[37.24] 1.170[29.72] 1.250[31.75] FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW AMP, PACKARD 58 AMP, PACKARD 58 10 3 2 1 8 7 4 5 6 9 10 3 2 1 8 7 4 5 6 9 VC1 VC1 VC1 VC2 VC2 VC2 3 VCH 2 1 8 VCH 7 4 5 VCH 6 CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING A A A A MARKING DETAIL 1.266[32.16] MARKING DE 1.466[37.24] TAIL 1.266[32.16] MARKING DETAIL 1.466[37.24] MARKING DETAIL 1.250[31.75] MARKING DETAIL MARKING DETAIL (For AMP terminals only) (For AMP terminals only) (For AMP terminals only) PACKARD 630 PACKARD 630 VC1 VC2 VC2 VCH PACKARD 630 PACKARD 630 VC1 VC1 VC2 FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW .950[24.13] B B CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL B B AMP, PACKARD 58 AMP, PACKARD 58 AMP AMP FRONT VIEW REAR VIEW FRON (For T VIEW AMP terminals only) REAR VIEW FRONT VIEW REAR VIEW AMP, PACKARD 58 AMP, PACKARD 58 10 3 2 1 8 7 4 5 6 9 10 3 2 1 8 7 4 5 6 9 VC1 VC2 VCH 3 2 1 8 7 4 5 6 VC1 CONNEC VC2TOR HOUSING VCH CONNECTOR HOUSING CONNECTOR HOUSING 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.250[31.75] CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING (For AMP terminals only) (For AMP terminals only) MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW 1.050[26.67] 1.050[26.67] 1.050[26.67] Contura X Boot (P/N VB1-01) Additional V-Series Ratings VC1 VC2 VCH CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING 1 .4VA @ 28VDC Resistive (For AMP terminals only) VB1-01 VB1-01 VB1-01 4 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings 2.000[50.80] 2.000[50.80] 2.000[50.80] 1.050[26.67] CONTURA X BOOT CONTURA X BOOT CONTURA X BOOT 1 1.050[26.67] 5 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified 1.050[26.67] B 15A 24V C 20A 18V VB1-01 VB1-01 2.000[50.80] CONTURA X BOOT .757[19.23] .757[19.23] .757[19.23] D 20A 12V 2.000[50.80] CONTURA X BOOT 1.050[26.67] VB1-01 E 20A 14V, 10A 14VT (circuits 1, 4, A, & D only) 2.000[50.80] CONTURA X BOOT F 10A 14V, 6A, 14VT (circuit G only) VB1-01 2.000[50.80] CONTURA X BOOT .757[19.23] G 20A 6V H 20A 3V .757[19.23] 2 L 15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L 3.99 [101.35] 3.99 [101.35] 3.99 [101.35] .757[19.23] M .4VA/20A 12V (combi-contact) .757[19.23] (combination gold/silver contacts for borderline dry circuit applications) VRT VRT VRT ACTUATOR REMO ACTU VALA TOR REMO ACTU VAL ATOR REMOVAL INSERT POINTS UNDER INSERT POINTS UNDER INSERT POINTS UNDER N .4VA/15A 24V (combi-contact) Contura II, III, IV, V, VI & VII Actuator 3.99 [101.35] ACTUATOR ACTUATOR .900 [22.86] ACTUATOR .900 [22.86] T.900 [22.86] OOL TOOL TOOL HOLD FLUSH ON BRACKET AND PUSH HOLD FLUSH ON BRACKET AND PUSH HOLD FLUSH ON BRACKET AND PUSH IN IN IN (For flush bracket) (combination gold/silver contacts for borderline dry circuit applications) (For flush bracket) (For flush bracket) TOP TOP TOP VRT Removal Tool (P/N VRT) ACTUATOR REMOVAL INSERT POINTS UNDER ACTUATOR .900 [22.86] TOOL HOLD FLUSH ON BRACKET AND PUSH NOTES IN (For flush bracket) 3.99 [101.35] TOP 3.99 [101.35] Consult factory to determine availability for individual circuits and their HP rating. 3.99 [101.35] VRT 1. Not available with Contura 7 or 14 rocker styles. ACTUATOR REMOVAL INSERT POINTS UNDER VRT ACTUATOR .900 [22.86] TOOL 2. Rating L available with circuits 1, 4, A & D only. HOLD FLUSH ON BRACKET AND PUSH IN (For flush bracket) ACTUATOR REMOVAL VRT INSERT POINTS UNDER TOP ACTUATOR .900 [22.86] ACTUATOR REMO T V OOL AL INSERT POINTS UNDER HOLD FLUSH ON BRACKET AND PUSH ACTUATIN OR .900 [22.86] TOOL (For flush bracket) HOLD FLUSH ON BRACKET AND PUSH IN TOP (For flush bracket) TOP Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com TOP TOP TOP TOP TOP TOP TOP | V-Series Contura Sealed Rocker Switches - Accessories 23 Contura Mounting Panels Dimensional Specifications: in. [mm] Contura Hole Plug Dimensional Specifications: in. [mm] 1.450 [36.83] TEST CUT VHP HOLE IN .830 [21.08] ACTUAL CONTURA II,III HOLE PLUG MATERIAL 1.240 [31.50] 1.820 [46.23] VHP .430 [10.92] CONTURA II,III HOLE PLUG VH2 STANDARD HOLE PLUG (With wing serrations) VH1 STANDARD HOLE PLUG (No wing serrations) 2.000 [50.80] (With VC1 connector attached) 1.067 [27.10] DETAIL VIEW VH3 VH4 VH1,VH3 & VH5 CONTURA IV HOLE PLUG CONTURA IV HOLE PLUG HOLE PLUGS (No wing serrations) (With wing serrations) (No wing serrations 1.928 [48.97] for ease of removal) 1.020 [25.91] DETAIL VIEW VH2,VH4 & VH6 VH5 VH6 HOLE PLUGS CONTURA V HOLE PLUG CONTURA V HOLE PLUG (No wing serrations) (With wing serrations) (With wing serrations) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 24 Notes Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | Sales Representatives, Distributors & Company Profile 25 Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. CANADA EUROPE USA MIDDLE EAST MEXICO AFRICA ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 @ Email: sales carlingtech.com @ Northern Region Sales Office: nrsm carlingtech.com @ Southeast Region Sales Office: sersm carlingtech.com @ Midwest Region Sales Office: mrsm carlingtech.com @ West Region Sales Office: wrsm carlingtech.com @ Latin America Sales Office: larsm carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Suite 1607, 16/F Tower 2, The Gateway, Harbour City, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 @ Email: sales carlingtech.com.hk @ Shenzhen, China: shenzhen carlingtech.com @ Shanghai, China: shanghai carlingtech.com @ Pune, India: india carlingtech.com @ Kaohsiung, Taiwan: taiwan carlingtech.com @ Yokohama, Japan: japan carlingtech.com | | Europe Middle East Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 @ Email: ltd.sales carlingtech.com @ Germany: gmbh carlingtech.com @ France: sas carlingtech.com www.carlingtech.com REV_04_2018

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the 999-16716-001?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Conn Housing F 8 POS Crimp ST Cable Mount VCH-01