CARLING TECHNOLOGIES AK2-B0-26-620-1C3-D
Description
Circuit Breaker Hydraulic Magnetic 2Pole 20A 250VAC
A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; max interrupting capacity of 5,000A. Compact & temp. stable. Front panel mounting. Available w/ choice of time delays & terminals w/ handle, rocker & metal toggle actuators. See datasheet.
Part Number
AK2-B0-26-620-1C3-D
Price
Request Quote
Manufacturer
CARLING TECHNOLOGIES
Lead Time
Request Quote
Category
Circuit Protection » Circuit Breaker
Specifications
Manufacturer
Carling Technologies
Manufacturers Part #
AK2-B0-26-620-1C3-D
Lead Time
On Order with Factory
Industry Aliases
AK2-B0-26-620-1C3-D
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
A-Series Circuit Breaker Well known for their proven reliability, the A-Series hydraulic/magnetic circuit breakers are compact, temperature stable and designed for precision operation in OEM markets requiring general purpose as well as full load amp applications. The A-Series circuit breakers are offered with ratings from 0.02 to 50 amps, up to 277VAC or 80VDC and are available with several choices of pole configurations, time delays, terminals, with a wide range of standard colors, imprinting and actuator styles. Actuator styles include handle for 1-6 poles and rocker 1 POLE - PUSH TO RESET 2 POLE - HANDLE for 1-3 pole construction. When front panel operation and aesthetics demand a clean, contemporary design, a two- color or solid color Visi-Rocker actuator, indicating either the ON mode or the TRIPPED/OFF mode, is ideally suitable. The new Rockerguard bezel and push-to-reset bezel, which help prevent inadvertent actuation, is also available. Features: Meets CSA Standard 22.2 No. 100 for the Generator & Welder markets 1 POLE - TOGGLE Specially constructed version available for applications requiring CE markings Applications: Agency Certifications: Marine UL Recognized – UL Standard 508, 1077, 1500 Telecommunications UL Listed – UL Standard 489A Military CSA Accepted Renewable Energy Systems TUV Certified Generators & Welder VDE Certified Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062-1177 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: sales@carlingtech.com • www.carlingtech.com | 2 A-Series Circuit Breaker - General Specifications Electrical Mechanical Endurance 6,000 ON-OFF operations @ 6 per Maximum Voltage 277VAC 50/60 Hz, 80VDC Current Ratings Standard current coils: 0.100, 0.250, minute; with rated Current & Voltage. 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, Additional 4,000 ON-OFF mechanical. 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, Trip Free All A-Series Circuit Breakers will trip 50.0. Other ratings available - consult on overload, even when the actuator is forcibly held in the ON position. ordering scheme. Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings Trip Indication The operating actuator moves available, consult ordering scheme. positively to the OFF position when Auxiliary Switch Rating SPDT; 10.1 A - 250VAC, an overload causes the circuit breaker 1.0 A-65VDC/0.5 A - 80 VDC, to trip. When mid-trip handle is specified, the handle moves to the 0.1A - 125VAC (with gold contacts). Insulation Resistance Minimum: 100 Megohms at 500 VDC mid position on electrical trip of the Dielectric Strength UL, CSA - 1500V 60 Hz for one circuit breaker. When mid-trip handle minute between all electrically with alarm switch is specified, the isolated terminals. A-Series rocker handle moves to the mid position & the alarm switch actuates when the circuit breakers comply with the 8mm spacing & 3750V dielectric circuit breaker is electrically tripped. requirements from hazardous voltage Physical to operator accessible surfaces per EN 60950 and VDE 0805. Number of Poles 1 - 6 Poles (handle) and 1-3 poles Resistance, Impedance Values from Line to Load Terminal - (rocker) at 30 Amps or less. based on Series Trip Circuit Breaker. Internal Circuit Config. Series, (with or without auxiliary RESISTANCE PER POLE VALUES switch), Shunt and Relay with current from Line to Load Terminals or voltage trip coils, Dual Coil, Switch (Values Based on Series Trip Circuit Breaker) Only with or without auxiliary switch. Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole) Standard Colors Housing - Black; Actuator- See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10- 55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition Pulse Tolerance Curves A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.56 days @ +85°C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40°C to +85°C. Ingress Protection For Sealed Toggle only. Meets MIL- PRF-55629 Requirements. ±15 PSI when installed in a panel. *Manufacturer reserves the right to change product specification without prior notice. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Circuit Breaker - General Specifications 3 Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. Handle Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80 A maximum. 3 2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1Ø Power System. 4 Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 4 A-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. 1 3 2 3 2 3 2 Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 2, except that backup fuse is limited to 80 A maximum. 4 Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Circuit Breaker - General Specifications 5 Electrical Tables Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. A-SERIES TABLE C: UL1500 (Marine Ignition Protected) CURRENT SHORT CIRCUIT VOLTAGE APPLICATION CODES CAPACITY (AMPS) RATING CIRCUIT CONFIGURATION WITHOUT BACKUP MAX. RATING FREQUENCY PHASE FULL LOAD AMPS UL CSA FUSE 1 SERIES DC --- 0.02 - 50 5000 TC1,OL1,U1 TC1,OL1,U1 14 1 DC --- 0.02 - 50 5000 TC1,OL1,U2 TC1,OL1,U2 32 65 DC --- 0.02 - 50 3000 TC1,OL1,U1 TC1,OL1,U1 12550 / 60 10.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 2 125 / 25050 / 60 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 1 25050 / 60 10.02 - 30 1500 TC1,OL1,U1 TC1,OL1,U1 Notes: Notes: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system 1Available with Special Catalog Number Only (consult factory) 22 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. Notes: 1 Parallel Pole Construction Agency Certifications UL Recognized CSA Accepted Component Supplementary UL Standard 1077 Component Recognition Program Protector under Class 3215 30, as Protectors Supplementary File 047848 0 000 CSA (Guide CCN/QVNU2, File E75596) Standard C22.2 No. 235 UL Standard 508 Switches, Industrial Control TUV Certified EN60934, under License No. (Guide CCN/NRNT2, File E148683) R72040875 Protectors, Supplementary for UL Standard 1500 Marine Electrical & Fuel Systems VDE Certified EN60934, VDE 0642 under File (Guide PEQZ2, File E75596) No. 10537 Ignition Protection UL Listed Communications Equipment UL Standard 489A (Guide CCN/DITT, File E189195) 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 6 A-Series Handle UL Recognized – Ordering Scheme A A 3 — B 0 — 10 — 450 — 1 B 1 — C 1 2 3 4 5 6 7 8 9 10 11 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Agency Color Barriers Approval Switch & Delay 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES A 020 0.020 225 0.250 420 2.000 611 11.000 025 0.025 230 0.300 522 2.250 711 11.500 1 2 ACTUATOR 030 0.030 235 0.350 527 2.750 612 12.000 A Handle, one per pole 035 0.035 240 0.400 430 3.000 712 12.500 B Handle, one per multipole unit 040 0.040 245 0.450 435 3.500 613 13.000 S Mid-Trip Handle, one per pole 045 0.045 250 0.500 440 4.000 614 14.000 T Mid-Trip Handle, one per pole & Alarm Switch 050 0.050 255 0.550 445 4.500 615 15.000 055 0.055 260 0.600 450 5.000 616 16.000 060 0.060 265 0.650 455 5.500 617 17.000 3 POLES 065 0.065 270 0.700 460 6.000 618 18.000 1 One 3 Three 5 Five 070 0.070 275 0.750 465 6.500 620 20.000 2 Two 4 Four 6 Six 075 0.075 280 0.800 470 7.000 622 22.000 080 0.080 285 0.850 475 7.500 624 24.000 085 0.085 290 0.900 480 8.000 625 25.000 3 4 CIRCUIT F Relay Trip (Current) 090 0.090 295 0.950 485 8.500 630 30.000 2 3 8 A Switch Only (No Coil) G Relay Trip (Voltage) 095 0.095 410 1.000 490 9.000 635 35.000 3,4 8 B Series Trip (Current) H Dual Coil with Shunt Trip 210 0.100 512 1.250 495 9.500 640 40.000 8 C Series Trip (Voltage) Voltage Coil 215 0.150 415 1.500 610 10.000 645 45.000 3 3,4 8 D Shunt Trip (Current) K Dual Coil with Relay Trip 220 0.200 517 1.750 710 10.500 650 50.000 3 E Shunt Trip (Voltage) Voltage Coil 6 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) CODE AMPERES A06 6 DC A32 32 DC J12 12 AC J65 65 AC 5 A12 12 DC A48 48 DC J18 18 AC K20 120 AC 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.093 Q.C. Term. A18 18 DC A65 65 DC J24 24 AC L40 240 AC 0 w/o Aux Switch (Gold Contacts) A24 24 DC J06 6 AC J48 48 AC 1 S.P.D.T., 0.093 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 2 S.P.D.T., 0.110 Q.C. Term. 7 S.P.S.T., 0.110 Q.C. Term. 3 S.P.D.T., 0.139 Solder Lug (Gold Contacts) 9 11 8 TERMINAL E Screw M4 (Bus Type) 4 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. 10 1 Push-On 0.250 Tab (Q.C.) F Screw M5 w/upturned lugs (Gold Contacts) 9 S.P.D.T., 0.187 Q.C. Term. 2 Screw 8-32 w/upturned lugs and 30° bend 11 3 Screw 8-32 (Bus Type) G Screw M5 (Bus Type) 4 Screw 10-32 w/upturned lugs and 30° bend 6 FREQUENCY & DELAY 11 11 5 Screw 10-32 (Bus Type) H Screw M5 (Bus Type) 03 DC 50/60Hz, Switch Only 30 DC, 50/60Hz Instantaneous 12 6 Screw 8-32 w/upturned lugs L 0.250 Q.C./ Solder Lug 10 DC Instantaneous 31 DC, 50/60Hz Ultra Short 11 and 30° bend M M6 Threaded Stud 11 DC Ultra Short 32 DC, 50/60Hz Short 14 7 Screw 8-32 (Bus Type) and Q Push-In Stud 12 DC Short 34 DC, 50/60Hz Medium 30° bend R Screw M4 w/upturned lugs 14 DC Medium 36 DC, 50/60Hz Long 7 8 Screw 10-32 w/upturned lugs and 30° bend 16 DC Long 42 50/60Hz Short, Hi-Inrush 11 7 and 30° bend T Screw M4 (Bus Type) 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 7 9 Screw 10-32 (Bus Type) and and 30° bend 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 13 7 30° bend P Printed Circuit Board 22 50/60Hz Short 52 DC, Short,Hi-Inrush 7 B Screw M5 w/upturned lugs Terminals 24 50/60Hz Medium 54 DC, Medium, Hi-Inrush 13 7 C Screw M4 w/upturned lugs S Push-On 0.110 Tab (Q.C.) 26 50/60Hz Long 56 DC, Long, Hi-Inrush Notes: 1 Actuator Code: 9 ACTUATOR COLOR & LEGEND A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. Acuator Color I-O ON-OFF Dual Legend Color B: Handle location as viewed from front of breaker: White A B 1 Black 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles Black C D 2 White 5 pole - three handles at center poles 6 pole - four handles at center poles Red F G 3 White S: Handle moves to mid-position only upon electrical trip of the breaker. Available with Green H J 4 White circuit codes B, C, D, E, F, G, H and K. Blue K L 5 White T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the Yellow M N 6 Black breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a Gray P Q 7 Black protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, Orange R S 8 Black select Current Code 630. For 35 - 50 amps, select Current Code 650. 15 Black (short handle) T U 9 White 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 50A amps maximum. 4 Consult factory for available Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils 10 MOUNTING/BARRIERS require 30VA minimum power to trip and are rated for intermittent duty only. MOUNTING STYLE BARRIERS 5 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A - supplied with Threaded Insert, 2 per pole standard half shells. 35-50A - supplied with extended boat (B-Style) half shells. 1 6-32 x 0.195 inches no On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay A 6-32 x 0.195 inches yes codes 10 and 20. 2 ISO M3 x 5mm no 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA B ISO M3 x 5mm (multipole only) yes Accepted & TUV Certified to 50 amps. Front panel Snap-In, 0.75” wide bezel 8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition 5 without Handleguard no and CSA Accepted available in one and two pole breakers. 6 without Handleguard (multipole only) yes 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 Front panel Snap-In, 0.96” wide bezel amps are only available with Terminal Codes 5, 9, G, H, M and Q.. 7 without Handleguard, 1-pole 0.96” wide; no 10 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA multipole units have .105” bezel overhang on all sides Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers, 8 without Handleguard, 1-pole 0.96” wide; yes and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat (multipole only) .105” bezel overhang on all sides Washers. These breakers are only VDE Certified when the washers are used. 12 Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted available up to 30A. 11 AGENCY APPROVAL 13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps C UL Recognized & CSA Accepted with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are D VDE Certified, UL Recognized & CSA Accepted available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. E TUV Certified, UL Recognized & CSA Accepted 14 Terminal Code Q not available with VDE certification. I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted 15 Single pole only. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Handle UL489A – Ordering Scheme 7 A A 1 — B 0 — 14 — 450 — 1 B 1 — M T 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. Appl. Agency Color Barriers Rating Approval Switch & Delay 1 SERIES 9 ACTUATOR COLOR & LEGEND A Acuator Color I-O Dual Legend Color White B 1 Black Black D 2 White 1 2 ACTUATOR Red G 3 White A Handle, one per pole Green J 4 White S Mid-Trip Handle, one per pole Blue L 5 White T Mid-Trip Handle, one per pole & Alarm Switch Yellow N 6 Black Gray Q 7 Black Orange S 8 Black 2 3 POLES 10 Black (short handle) U 9 White 1 One 3 Three 2 Two 4 Four 10 MOUNTING/BARRIERS MOUNTING STYLE BARRIERS 4 CIRCUIT Threaded Insert, 2 per pole B Series Trip (Current) 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches yes 2 ISO M3 x 5mm no 2 5 AUXILIARY/ALARM SWITCH B ISO M3 x 5mm (multipole only) yes 0 w/o Aux Switch 7 S.P.S.T., 0.110 Q.C. Term. Front panel Snap-In, 0.75” wide bezel 1 S.P.D.T., 0.093 Q.C. Term. (Gold Contacts) 5 without Handleguard no 2 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. 6 without Handleguard (multipole only) yes 3 S.P.D.T., 0.139 Solder Lug 9 S.P.D.T., 0.187 Q.C. Term. Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 6 FREQUENCY & DELAY 8 without Handleguard, 1-pole 0.96” wide; yes 3 11 DC Ultra Short 52 DC, Short,Hi-Inrush (multipole only) .105” bezel overhang on all sides 3 12 DC Short 54 DC, Medium, Hi-Inrush 3 14 DC Medium 56 DC, Long, Hi-Inrush 16 DC Long 11 MAXIMUM APPLICATION RATING M 80 DC 7 CURRENT RATING (AMPERES) CODE AMPERES 210 0.100 285 0.850 455 5.500 613 13.000 12 AGENCY APPROVAL 215 0.150 290 0.900 460 6.000 614 14.000 T UL489A LISTED 220 0.200 295 0.950 465 6.500 615 15.000 K UL489A LISTED, VDE CERTIFIED 225 0.250 410 1.000 470 7.000 616 16.000 J UL489A LISTED, TUV CERTIFIED 230 0.300 512 1.250 475 7.500 617 17.000 235 0.350 415 1.500 480 8.000 618 18.000 240 0.400 517 1.750 485 8.500 620 20.000 Notes: 245 0.450 420 2.000 490 9.000 622 22.000 1 Actuator Code: 250 0.500 522 2.250 495 9.500 624 24.000 A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. 255 0.550 527 2.750 610 10.000 625 25.000 S: Handle moves to mid-position only upon electrical trip of the breaker. 260 0.600 430 3.000 710 10.500 630 30.000 T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the 3 breaker. 265 0.650 435 3.500 611 11.000 635 35.000 3 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 270 0.700 440 4.000 711 11.500 640 40.000 3 3 VDE Certified to 30 amps. UL489A Listed to 50 amps. 275 0.750 445 4.500 612 12.000 645 45.000 4 VDE Certification available with single pole breakers only. UL489A Listing available with one 3 280 0.800 450 5.000 712 12.500 650 50.000 and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9 G, H, M and Q. 5 8 TERMINAL 9 Screw 10-32 (Bus Type) and 6 Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps with 6 UL489A Listing, but is not recommended over 20 amps. 1 Push-On 0.250 Tab (Q.C.) 30° bend 7 Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and 2 Screw 8-32 w/upturned lugs B Screw M5 w/upturned lugs Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. 7 3 Screw 8-32 (Bus Type) F Screw M5 w/upturned lugs These breakers are only VDE Certified when the washers are used. 4 Screw 10-32 w/upturned lugs and 30° bend 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps 7 5 Screw 10-32 (Bus Type) G Screw M5 (Bus Type) with VDE Certification and 50 amps with UL489A Listing. 6 Screw 8-32 w/upturned lugs and 30° bend 9 Terminal Code Q not available with VDE certification. and 30° bend H Screw M5 (Bus Type) 10 Single pole only. 7 7 Screw 8-32 (Bus Type) and M M6 Threaded Stud 8 30° bend P Printed Circuit Board Terminals 9 8 Screw 10-32 w/upturned lugs Q Push-In Stud and 30° bend 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 8 A-Series Handle WORLD – Ordering Scheme A A 3 — B 0 — 14 — 450 — 1 A 1 — P 1 2 3 4 5 6 7 8 9 10 11 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Agency Color Barriers Approval Switch & Delay 9 1 SERIES 8 TERMINAL 10 A 1 Push-On 0.250 Tab (Q.C.) B Screw M5 w/upturned lugs 2 Screw 8-32 w/upturned lugs C Screw M4 w/upturned lugs 11 11 3 Screw 8-32 (Bus Type) E Screw M4 (Bus Type) 1 2 ACTUATOR 4 Screw 10-32 w/upturned lugs F Screw M5 w/upturned lugs A Handle, one per pole 11 5 Screw 10-32 (Bus Type) and 30° bend B Handle, one per multi-pole unit 6 Screw 8-32 w/upturned lugs G Screw M5 (Bus Type) S Mid-Trip Handle, one per pole and 30° bend and 30° bend T Mid-Trip Handle, one per pole & Alarm Switch 11 7 Screw 8-32 (Bus Type) and H Screw M5 (Bus Type) 30° bend R Screw M4 w/upturned lugs 8 Screw 10-32 w/upturned lugs and 30° bend 11 3 POLES and 30° bend T Screw M4 (Bus Type) 1 One 3 Three 5 Five 9 Screw 10-32 (Bus Type) and and 30° bend 2 Two 4 Four 6 Six 30° bend 3 4 CIRCUIT D Shunt Trip (Current) 9 ACTUATOR COLOR & LEGEND 2 3 A Switch Only (No Coil) E Shunt Trip (Voltage) Acuator Color I-O Dual Legend Color 3,4 B Series Trip (Current) H Dual Coil with Shunt Trip White A 1 Black C Series Trip (Voltage) Voltage Coil Black C 2 White Red F 3 White Green H 4 White 5 5 AUXILIARY/ALARM SWITCH Blue K 5 White 0 w/o Aux Switch 4 S.P.D.T., 0.110 Q.C. Term. Yellow M 6 Black 2 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) Gray P 7 Black 3 S.P.D.T., 0.139 Solder Lug Orange R 8 Black 6 FREQUENCY & DELAY 10 MOUNTING/BARRIERS 03 DC 50/60Hz, Switch Only 30 DC, 50/60Hz Instantaneous MOUNTING STYLE BARRIERS 10 DC Instantaneous 31 DC, 50/60Hz Ultra Short Threaded Insert, 2 per pole 11 DC Ultra Short 32 DC, 50/60Hz Short 1 6-32 x 0.195 inches no 12 DC Short 34 DC, 50/60Hz Medium A 6-32 x 0.195 inches yes 14 DC Medium 36 DC, 50/60Hz Long 2 ISO M3 x 5mm no 7 16 DC Long 42 50/60Hz Short, Hi-Inrush B ISO M3 x 5mm (multipole only) yes 7 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush Front panel Snap-In, 0.75” wide bezel 7 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 5 without Handleguard no 7 22 50/60Hz Short 52 DC, Short,Hi-Inrush 6 without Handleguard (multipole only) yes 7 24 50/60Hz Medium 54 DC, Medium, Hi-Inrush Front panel Snap-In, 0.96” wide bezel 7 26 50/60Hz Long 56 DC, Long, Hi-Inrush 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; yes 7 CURRENT RATING (AMPERES) (multipole only) .105” bezel overhang on all sides CODE AMPERES 210 0.100 285 0.850 455 5.500 613 13.000 215 0.150 290 0.900 460 6.000 614 14.000 11 AGENCY APPROVAL 220 0.200 295 0.950 465 6.500 615 15.000 P TUV Certified, UL Recognized & CSA Accepted 225 0.250 410 1.000 470 7.000 616 16.000 Q UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted 230 0.300 512 1.250 475 7.500 617 17.000 235 0.350 415 1.500 480 8.000 618 18.000 240 0.400 517 1.750 485 8.500 620 20.000 Notes: 245 0.450 420 2.000 490 9.000 622 22.000 1 Actuator Code: 250 0.500 522 2.250 495 9.500 624 24.000 A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. 255 0.550 527 2.750 610 10.000 625 25.000 S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, and H. 260 0.600 430 3.000 710 10.500 630 30.000 8 T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the 265 0.650 435 3.500 611 11.000 635 35.000 8 breaker. Available with circuit codes B & C. 270 0.700 440 4.000 711 11.500 640 40.000 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a 8 275 0.750 445 4.500 612 12.000 645 45.000 protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630. 8 280 0.800 450 5.000 712 12.500 650 50.000 For 35 - 50 amps, select Current Code 650. 6 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. CODE AMPERES 4 Consult factory for available Dual Coil options, as special catalog number is required. A06 6 DC A32 32 DC J12 12 AC J65 65 AC With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require A12 12 DC A48 48 DC J18 18 AC K20 120 AC 30VA minimum power to trip and are rated for intermittent duty only. 5 On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole. A18 18 DC A65 65 DC J24 24 AC L40 240 AC 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay A24 24 DC J06 6 AC J48 48 AC codes 10, 20 & 30. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 Available up to two poles with AC or DC delays. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G and H. 10 Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps. 11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers. These breakers are only TUV Certified when the washers are used. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Rocker UL489A – Ordering Scheme 9 A F 1 — B 0 — 14 — 450 — 1 3 1 — M T 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. Appl. Agency Color Barriers Rating Approval Switch & Delay 5 1 SERIES 8 TERMINAL 9 Screw 10-32 (Bus Type) and 6 A 1 Push-On 0.250 Tab (Q.C.) 30° bend 2 Screw 8-32 w/upturned lugs B Screw M5 w/upturned lugs 7 3 Screw 8-32 (Bus Type) F Screw M5 w/upturned lugs 1 2 ACTUATOR 4 Screw 10-32 w/upturned lugs and 30° bend 7 Two Color Visi-Rocker Push-To-Reset, Visi-Rocker 5 Screw 10-32 (Bus Type) G Screw M5 (Bus Type) C Indicate ON, vertical legend N Indicate OFF, 6 Screw 8-32 w/upturned lugs and 30° bend D Indicate ON, horizontal legend vertical legend and 30° bend H Screw M5 (Bus Type) 7 F Indicate OFF, vertical legend O Indicate OFF, 7 Screw 8-32 (Bus Type) and M M6 Threaded Stud 8 G Indicate OFF, horizontal legend horizontal legend 30° bend P Printed Circuit Board Terminals 9 Single color Push-To-Reset , Single color 8 Screw 10-32 w/upturned lugs Q Push-In Stud J Vertical legend R Vertical legend and 30° bend K Horizontal legend U Horizontal legend 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color 10 10 Visi-Color ON-OFF Dual Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 11 10 MOUNTING/BARRIERS 2 3 POLES STANDARD ROCKER BEZEL BARRIERS 1 One 2 Two 3 Three Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 4 CIRCUIT 2 ISO M3 x 5mm no B Series Trip (Current) B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 3 5 AUXILIARY/ALARM SWITCH 3 6-32 x 0.195 inches no 0 w/o Aux Switch 7 S.P.S.T., 0.110 Q.C. Term. C 6-32 x 0.195 inches (multi-pole units only) yes 1 S.P.D.T., 0.093 Q.C. Term. (Gold Contacts) 4 ISO M3 x 5mm no 2 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. D ISO M3 x 5mm (multi-pole units only) yes 3 S.P.D.T., 0.139 Solder Lug 9 S.P.D.T., 0.187 Q.C. Term. FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel 8 without Rockerguard (single pole units only) no H with Rockerguard (single pole units only) no 6 FREQUENCY & DELAY FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel 11 DC Ultra Short 52 DC, Short,Hi-Inrush 9 without Rockerguard (single pole units only) no 12 DC Short 54 DC, Medium, Hi-Inrush J with Rockerguard (single pole units only) no 14 DC Medium 56 DC, Long, Hi-Inrush 16 DC Long 11 MAXIMUM APPLICATION RATING M 80 DC 7 CURRENT RATING (AMPERES) CODE AMPERES 210 0.100 285 0.850 455 5.500 613 13.000 12 AGENCY APPROVAL 215 0.150 290 0.900 460 6.000 614 14.000 T UL489A LISTED 220 0.200 295 0.950 465 6.500 615 15.000 K UL489A LISTED, VDE CERTIFIED 225 0.250 410 1.000 470 7.000 616 16.000 J UL489A LISTED, TUV CERTIFIED 230 0.300 512 1.250 475 7.500 617 17.000 235 0.350 415 1.500 480 8.000 618 18.000 Notes: 240 0.400 517 1.750 485 8.500 620 20.000 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 245 0.450 420 2.000 490 9.000 622 22.000 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or 250 0.500 522 2.250 495 9.500 624 24.000 mixed poles, and have one rocker per breaker. 255 0.550 527 2.750 610 10.000 625 25.000 3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 260 0.600 430 3.000 710 10.500 630 30.000 30-50A are supplied with extended boat (B-Style) half shells. 4 265 0.650 435 3.500 611 11.000 635 35.000 4 VDE Certification available with single pole breakers only. UL489A Listing available with one 4 270 0.700 440 4.000 711 11.500 640 40.000 and two pole breakers. 4 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps 275 0.750 445 4.500 612 12.000 645 45.000 4 are only available with Terminal Codes 5, 9, G, H, M and Q. 280 0.800 450 5.000 712 12.500 650 50.000 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 10 A-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Handle – Circuit & Terminal Diagrams 11 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 QC & solder lug terminals only. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 12 A-Series Handle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified. 3 For agency code P = .150 [3.81]. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Handle – Front Panel Snap-In Mounting Style 5 13 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 14 A-Series Handle – Front Panel Snap-In Mounting Style 7 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Sealed Toggle UL Recognized – Ordering Scheme 15 A M 1 — B 0 — 10 — 450 — 1 0 1 — C 1 2 3 4 5 6 7 8 9 10 11 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Agency Color Barriers Approval Switch & Delay 9 11 1 SERIES 8 TERMINAL E Screw M4 (Bus Type) 10 A 1 Push-On 0.250 Tab (Q.C.) F Screw M5 w/upturned lugs 2 Screw 8-32 w/upturned lugs and 30° bend 11 3 Screw 8-32 (Bus Type) G Screw M5 (Bus Type) 1 2 ACTUATOR 4 Screw 10-32 w/upturned lugs and 30° bend M Sealed Toggle, one per unit 11 11 5 Screw 10-32 (Bus Type) H Screw M5 (Bus Type) 12 6 Screw 8-32 w/upturned lugs L 0.250 Q.C./ Solder Lug 11 and 30° bend M M6 Threaded Stud 14 3 POLES 7 Screw 8-32 (Bus Type) and Q Push-In Stud 1 One 30° bend R Screw M4 w/upturned lugs 2 Two 8 Screw 10-32 w/upturned lugs and 30° bend 11 3 Three and 30° bend T Screw M4 (Bus Type) 9 Screw 10-32 (Bus Type) and and 30° bend 13 30° bend P Printed Circuit Board 3 B Screw M5 w/upturned lugs Terminals 4 CIRCUIT F Relay Trip (Current) 13 2 3 C Screw M4 w/upturned lugs S Push-On 0.110 Tab (Q.C.) A Switch Only (No Coil) G Relay Trip (Voltage) 3,4 B Series Trip (Current) H Dual Coil with Shunt Trip C Series Trip (Voltage) Voltage Coil 3 3,4 D Shunt Trip (Current) K Dual Coil with Relay Trip 9 LEGEND PLATE 3 E Shunt Trip (Voltage) Voltage Coil 0 No legend plate 5 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.093 Q.C. Term. 10 MOUNTING/BARRIERS 0 w/o Aux Switch (Gold Contacts) MOUNTING STYLE BARRIERS 1 S.P.D.T., 0.093 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 1 Standard Hex Nut no 2 S.P.D.T., 0.110 Q.C. Term. 7 S.P.S.T., 0.110 Q.C. Term. A Standard Hex Nut (multipole only) yes 3 S.P.D.T., 0.139 Solder Lug (Gold Contacts) 4 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. (Gold Contacts) 9 S.P.D.T., 0.187 Q.C. Term. 11 AGENCY APPROVAL C UL Recognized & CSA Accepted I UL Recognized, CSA Accepted, UL1500 Ignition Protected 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 30 DC, 50/60Hz Instantaneous Notes: 10 DC Instantaneous 31 DC, 50/60Hz Ultra Short 1 Actuator Code M: Handle location as viewed from front of panel: 11 DC Ultra Short 32 DC, 50/60Hz Short 2 pole - right pole 3 pole - center pole 12 DC Short 34 DC, 50/60Hz Medium 2 Switch Only circuits, rated up to 50 amps and 3 poles. Only available when tied to a protected 14 DC Medium 36 DC, 50/60Hz Long pole. For .02 to 30 amps, select Current 7 16 DC Long 42 50/60Hz Short, Hi-Inrush Code 630. For 35 - 50 amps, select Current Code 650. 7 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 7 4 Consult factory for available Dual Coil options, as special catalog number is required. With 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 7 Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA 22 50/60Hz Short 52 DC, Short,Hi-Inrush 7 minimum power to trip and are rated for intermittent duty only. 24 50/60Hz Medium 54 DC, Medium, Hi-Inrush 5 Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps. 7 26 50/60Hz Long 56 DC, Long, Hi-Inrush On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA 7 CURRENT RATING (AMPERES) Accepted & TUV Certified to 50 amps. CODE AMPERES 8 UL Recognition and CSA Certification available on one and two pole breakers. 020 0.020 225 0.250 420 2.000 611 11.000 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps 025 0.025 230 0.300 522 2.250 711 11.500 are only available with Terminal Codes 5, 9, G, H, M and Q.. 030 0.030 235 0.350 527 2.750 612 12.000 10 Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not recommended 035 0.035 240 0.400 430 3.000 712 12.500 over 20 amps. 11 Terminal Code L : available up to 30A. 040 0.040 245 0.450 435 3.500 613 13.000 12 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps, 045 0.045 250 0.500 440 4.000 614 14.000 with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) 050 0.050 255 0.550 445 4.500 615 15.000 are available up to 40 amps with Circuit Codes A, B and C. 055 0.055 260 0.600 450 5.000 616 16.000 060 0.060 265 0.650 455 5.500 617 17.000 065 0.065 270 0.700 460 6.000 618 18.000 070 0.070 275 0.750 465 6.500 620 20.000 075 0.075 280 0.800 470 7.000 622 22.000 080 0.080 285 0.850 475 7.500 624 24.000 085 0.085 290 0.900 480 8.000 625 25.000 090 0.090 295 0.950 485 8.500 630 30.000 8 095 0.095 410 1.000 490 9.000 635 35.000 8 210 0.100 512 1.250 495 9.500 640 40.000 8 215 0.150 415 1.500 610 10.000 645 45.000 8 220 0.200 517 1.750 710 10.500 650 50.000 6 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) CODE AMPERES A06 6 DC A32 32 DC J12 12 AC J65 65 AC A12 12 DC A48 48 DC J18 18 AC K20 120 AC A18 18 DC A65 65 DC J24 24 AC L40 240 AC A24 24 DC J06 6 AC J48 48 AC 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 16 A-Series Sealed Toggle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Rocker UL Recognized – Ordering Scheme 17 A F 1 — B 0 — 24 — 630 — 2 3 1 — D 1 2 3 4 5 6 7 8 9 10 11 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Agency Approval Switch & Delay Color Barriers 11 1 SERIES 8 TERMINAL 12 13 1 Push-On 0.250 Tab (Q.C.) E Screw M4 (Bus Type) A 2 Screw 8-32 w/upturned lugs F Screw M5 w/upturned lugs 13 3 Screw 8-32 (Bus Type) and 30° bend 1 2 ACTUATOR Push-To-Reset , Single color 4 Screw 10-32 w/upturned lugs G Screw M5 (Bus Type) 13 Two Color Visi-Rocker R Vertical legend 5 Screw 10-32 (Bus Type) and 30° bend 13 C Indicate ON, vertical legend U Horizontal legend 6 Screw 8-32 w/upturned lugs H Screw M5 (Bus Type) 14 and 30° bend L 0.250 Q.C./ Solder Lug D Indicate ON, horizontal legend V No legend 13 7 Screw 8-32 (Bus Type) and M M6 Threaded Stud E Indicate ON, no legend 15 30° bend P Printed Circuit BoardTerminals F Indicate OFF, vertical legend 16 8 Screw 10-32 w/upturned lugs Q Push-In Stud G Indicate OFF, horizontal legend and 30° bend R Screw M4 w/upturned lugs H Indicate OFF, no legend 9 Screw 10-32 (Bus Type) and and 30° bend Push-To-Reset, Visi-Rocker 17 30° bend S Push-On 0.110 Tab (Q.C.) N Indicate OFF, B Screw M5 w/upturned lugs T Screw M4 (Bus Type) vertical legend C Screw M4 w/upturned lugs and 30° bend O Indicate OFF, horizontal legend P Indicate OFF, 9 ACTUATOR COLOR & LEGEND no legend Actuator or Marking: Marking Color 12 12 Single color Visi-Color I-O ON-OFF Dual Single Color Visi-Rocker J Vertical legend White A B 1 Black White K Horizontal legend Black C D 2 White n/a L No legend Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow 3 POLES Gray P Q 7 Black Gray 1 One 2 Two 3 Three Orange R S 8 Black Orange 4 4 CIRCUIT F Relay Trip (Current) 20 10 MOUNTING/BARRIERS 3 4 A Switch Only (No Coil) G Relay Trip (Voltage) STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS 4,5 B Series Trip (Current) H Dual Coil with Shunt Trip 1 6-32 x 0.195 inches no C Series Trip (Voltage) Voltage Coil A 6-32 X 0.195 inches (multi-pole units only) yes 4 4,5 D Shunt Trip (Current) K Dual Coil with Relay Trip 2 ISO M3 x 5mm no 4 E Shunt Trip (Voltage) Voltage Coil B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no 6,7 C 6-32 x 0.195 inches (multi-pole units only) yes 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.093 Q.C. Term. 4 ISO M3 x 5mm no 0 w/o Aux Switch (Gold Contacts) D ISO M3 x 5mm (multi-pole units only) yes 1 S.P.D.T., 0.093 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug FRONT PANEL SNAP-IN BRACKET, 0.744” wide bezel 2 S.P.D.T., 0.110 Q.C. Term. 7 S.P.S.T., 0.110 Q.C. Term. 8 without Rockerguard (single pole units only) no 3 S.P.D.T., 0.139 Solder Lug (Gold Contacts) H with Rockerguard (single pole units only) no 4 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. FRONT PANEL SNAP-IN BRACKET, 0.96” wide bezel (Gold Contacts) 9 S.P.D.T., 0.187 Q.C. Term. 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) no 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 30 DC, 50/60Hz Instantaneous 11 AGENCY APPROVAL 10 DC Instantaneous 31 DC, 50/60Hz Ultra Short C UL Recognized & CSA Accepted 11 DC Ultra Short 32 DC, 50/60Hz Short D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted 12 DC Short 34 DC, 50/60Hz Medium I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted 14 DC Medium 36 DC, 50/60Hz Long 9 16 DC Long 42 50/60Hz Short, Hi-Inrush Notes: 9 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 9 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 9 and have one rocker per breaker. 22 50/60Hz Short 52 DC, Short,Hi-Inrush 3 Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected pole 9 24 50/60Hz Medium 54 DC, Medium, Hi-Inrush (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. 9 26 50/60Hz Long 56 DC, Long, Hi-Inrush For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, 7 CURRENT RATING (AMPERES) Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and CODE AMPERES are rated for intermittent duty only. 020 0.020 225 0.250 420 2.000 611 11.000 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard 025 0.025 230 0.300 522 2.250 711 11.500 half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 030 0.030 235 0.350 527 2.750 612 12.000 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 035 0.035 240 0.400 430 3.000 712 12.500 9 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted 040 0.040 245 0.450 435 3.500 613 13.000 & TUV Certified to 50 amps. 045 0.045 250 0.500 440 4.000 614 14.000 10 Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only. 050 0.050 255 0.550 445 4.500 615 15.000 UL Recognition & CSA Accepted available in one and two pole breakers. 055 0.055 260 0.600 450 5.000 616 16.000 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only 060 0.060 265 0.650 455 5.500 617 17.000 available with Terminal Codes 5, 9, G, H, M and Q. 065 0.065 270 0.700 460 6.000 618 18.000 12 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Accepted up to 30 amps, but not recommended over 20 amps. 070 0.070 275 0.750 465 6.500 620 20.000 13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M 075 0.075 280 0.800 470 7.000 622 22.000 (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE 080 0.080 285 0.850 475 7.500 624 24.000 Certified when the washers are used. 085 0.085 290 0.900 480 8.000 625 25.000 14 VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 090 0.090 295 0.950 485 8.500 630 30.000 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE 10 095 0.095 410 1.000 490 9.000 635 35.000 Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. 10 210 0.100 512 1.250 495 9.500 640 40.000 Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL 10 Recognition and CSA Certification with Circuit Codes A, B and C. 215 0.150 415 1.500 610 10.000 645 45.000 10 16 Terminal Code Q not available with VDE. 220 0.200 517 1.750 710 10.500 650 50.000 8 17 Terminal Code S used on voltage coil circuit constructions only. OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 18 Color shown is visi and legend with remainder of rocker black. A06 6 DC A32 32 DC J12 12 AC J65 65 AC 19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator A12 12 DC A48 48 DC J18 18 AC K20 120 AC 20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on A18 18 DC A65 65 DC J24 24 AC L40 240 AC Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard A24 24 DC J06 6 AC J48 48 AC available with actuator codes C through L. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 18 A-Series Flat Rocker UL Recognized – Ordering Scheme A 1 1 — B 0 — 24 — 630 — 2 3 1 — E 1 2 3 4 5 6 7 8 9 10 11 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Agency Approval Switch & Delay Color Barriers 11 1 SERIES 8 TERMINAL 12 13 A 1 Push-On 0.250 Tab (Q.C.) E Screw M4 (Bus Type) 2 Screw 8-32 w/upturned lugs F Screw M5 w/upturned lugs 13 3 Screw 8-32 (Bus Type) and 30° bend 1 2 ACTUATOR 4 Screw 10-32 w/upturned lugs G Screw M5 (Bus Type) Two Color Visi-Rocker 13 5 Screw 10-32 (Bus Type) and 30° bend 1 Indicate OFF, vertical legend 13 6 Screw 8-32 w/upturned lugs H Screw M5 (Bus Type) 2 Indicate OFF, horizontal legend 14 and 30° bend L 0.250 Q.C./ Solder Lug Single color 13 7 Screw 8-32 (Bus Type) and M M6 Threaded Stud 3 Vertical legend 15 30° bend P Printed Circuit BoardTerminals 4 Horizontal legend 8 Screw 10-32 w/upturned lugs Q Push-In Stud Push-To-Reset, Visi-Rocker and 30° bend R Screw M4 w/upturned lugs 5 Indicate OFF, vertical legend 9 Screw 10-32 (Bus Type) and and 30° bend 6 Indicate OFF, horizontal legend 16 30° bend S Push-On 0.110 Tab (Q.C.) Push-To-Reset , Single color B Screw M5 w/upturned lugs T Screw M4 (Bus Type) 7 Vertical legend C Screw M4 w/upturned lugs and 30° bend 8 Horizontal legend 9 ACTUATOR COLOR & LEGEND 2 Actuator or Marking: Marking Color 3 POLES 17 17 Visi-Color I-O ON-OFF Dual Single Color Visi-Rocker 1 One 2 Two 3 Three White A B 1 Black White Black C D 2 White n/a 4 Red F G 3 White Red 4 CIRCUIT F Relay Trip (Current) 3 4 Green H J 4 White Green A Switch Only (No Coil) G Relay Trip (Voltage) 4,5 Blue K L 5 White Blue B Series Trip (Current) H Dual Coil with Shunt Trip Yellow M N 6 Black Yellow C Series Trip (Voltage) Voltage Coil 4 4,5 Gray P Q 7 Black Gray D Shunt Trip (Current) K Dual Coil with Relay Trip 4 Orange R S 8 Black Orange E Shunt Trip (Voltage) Voltage Coil 18 10 MOUNTING/BARRIERS 6,7 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.093 Q.C. Term. STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS 0 w/o Aux Switch (Gold Contacts) FLAT ROCKER ACTUATOR 1 S.P.D.T., 0.093 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 1 6-32 x 0.195 inches no 2 S.P.D.T., 0.110 Q.C. Term. 7 S.P.S.T., 0.110 Q.C. Term. A 6-32 X 0.195 inches (multi-pole units only) yes 3 S.P.D.T., 0.139 Solder Lug (Gold Contacts) 2 ISO M3 x 5mm no 4 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. B ISO M3 x 5mm (multi-pole units only) yes (Gold Contacts) 9 S.P.D.T., 0.187 Q.C. Term. 19 RECESSED OFF SIDE ROCKER ACTUATOR 5 6-32 x 0.195 inches no E 6-32 x 0.195 inches (multi-pole units only) yes 6 FREQUENCY & DELAY 6 ISO M3 x 5mm no 03 DC 50/60Hz, Switch Only 30 DC, 50/60Hz Instantaneous F ISO M3 x 5mm (multi-pole units only) yes 6 10 DC Instantaneous 31 DC, 50/60Hz Ultra Short PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 11 DC Ultra Short 32 DC, 50/60Hz Short 3 6-32 x 0.195 inches no 12 DC Short 34 DC, 50/60Hz Medium C 6-32 x 0.195 inches (multi-pole units only) yes 14 DC Medium 36 DC, 50/60Hz Long 4 ISO M3 x 5mm no 9 16 DC Long 42 50/60Hz Short, Hi-Inrush 6 9 D ISO M3 x 5mm (multi-pole units only) yes 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 9 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 9 22 50/60Hz Short 52 DC, Short,Hi-Inrush 9 24 50/60Hz Medium 54 DC, Medium, Hi-Inrush 11 AGENCY APPROVAL 26 50/60Hz Long 56 DC, Long, Hi-Inrush C UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted 7 CURRENT RATING (AMPERES) Notes: CODE AMPERES 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 020 0.020 225 0.250 420 2.000 611 11.000 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, 025 0.025 230 0.300 522 2.250 711 11.500 and have one rocker per breaker. 030 0.030 235 0.350 527 2.750 612 12.000 3 Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected pole. 035 0.035 240 0.400 430 3.000 712 12.500 For .02 to 30 amps, select Current Code 630. 040 0.040 245 0.450 435 3.500 613 13.000 For 35 - 50 amps, select Current Code 650. 045 0.045 250 0.500 440 4.000 614 14.000 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, 050 0.050 255 0.550 445 4.500 615 15.000 Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and 055 0.055 260 0.600 450 5.000 616 16.000 are rated for intermittent duty only. 060 0.060 265 0.650 455 5.500 617 17.000 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half 065 0.065 270 0.700 460 6.000 618 18.000 shells. 30-50A are supplied with extended boat (B-Style) half shells. 070 0.070 275 0.750 465 6.500 620 20.000 7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 075 0.075 280 0.800 470 7.000 622 22.000 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 080 0.080 285 0.850 475 7.500 624 24.000 9 Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 085 0.085 290 0.900 480 8.000 625 25.000 10 UL Recognition, CSA Acceptance & TUV Certification available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only 090 0.090 295 0.950 485 8.500 630 30.000 10 available with Terminal Codes 5, 9, G, H, M and Q. 095 0.095 410 1.000 490 9.000 635 35.000 12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps. 10 210 0.100 512 1.250 495 9.500 640 40.000 13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal Code M 10 215 0.150 415 1.500 610 10.000 645 45.000 (M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV 10 220 0.200 517 1.750 710 10.500 650 50.000 Certified when the washers are used. 8 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 14 TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. A06 6 DC A32 32 DC J12 12 AC J65 65 AC 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps with UL Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers A12 12 DC A48 48 DC J18 18 AC K20 120 AC with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA A18 18 DC A65 65 DC J24 24 AC L40 240 AC Accepted with Circuit Codes A, B and C. A24 24 DC J06 6 AC J48 48 AC 16 Terminal Code S used on voltage coil circuit constructions only. 17 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 19 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Flat Rocker UL 489A – Ordering Scheme 19 A 1 1 — B 0 — 14 — 630 — 2 3 1 — M T 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. Appl. Agency Color Barriers Rating Approval Switch & Delay 5 1 SERIES 8 TERMINAL 9 Screw 10-32 (Bus Type) and 7 A 1 Push-On 0.250 Tab (Q.C.) 30° bend 2 Screw 8-32 w/upturned lugs B Screw M5 w/upturned lugs 8 3 Screw 8-32 (Bus Type) F Screw M5 w/upturned lugs 1 2 ACTUATOR 4 Screw 10-32 w/upturned lugs and 30° bend 8 Two Color Visi-Rocker Push-To-Reset, Visi-Rocker 5 Screw 10-32 (Bus Type) G Screw M5 (Bus Type) C Indicate ON, vertical legend N Indicate OFF, 6 Screw 8-32 w/upturned lugs and 30° bend 8 D Indicate ON, horizontal legend vertical legend and 30° bend H Screw M5 (Bus Type) 8 F Indicate OFF, vertical legend O Indicate OFF, 7 Screw 8-32 (Bus Type) and M M6 Threaded Stud 9 G Indicate OFF, horizontal legend horizontal legend 30° bend P Printed Circuit Board Terminals 10 Single color Push-To-Reset , Single color 8 Screw 10-32 w/upturned lugs Q Push-In Stud J Vertical legend R Vertical legend and 30° bend K Horizontal legend U Horizontal legend 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color 11 11 Visi-Color ON-OFF Dual Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 12 10 MOUNTING/BARRIERS 2 3 POLES STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS 1 One 2 Two 3 Three FLAT ROCKER ACTUATOR 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes 4 CIRCUIT 2 ISO M3 x 5mm no B Series Trip (Current) B ISO M3 x 5mm (multi-pole units only) yes RECESSED OFF SIDE ROCKER ACTUATOR 13 5 6-32 x 0.195 inches no 3 5 AUXILIARY/ALARM SWITCH E 6-32 x 0.195 inches (multi-pole units only) yes 0 w/o Aux Switch 7 S.P.S.T., 0.110 Q.C. Term. 6 ISO M3 x 5mm no 1 S.P.D.T., 0.093 Q.C. Term. (Gold Contacts) F ISO M3 x 5mm (multi-pole units only) yes 2 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 S.P.D.T., 0.139 Solder Lug 9 S.P.D.T., 0.187 Q.C. Term. 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes 4 ISO M3 x 5mm no 6 FREQUENCY & DELAY D ISO M3 x 5mm (multi-pole units only) yes 11 DC Ultra Short 52 DC, Short,Hi-Inrush 12 DC Short 54 DC, Medium, Hi-Inrush 14 DC Medium 56 DC, Long, Hi-Inrush 11 MAXIMUM APPLICATION RATING 16 DC Long M 80 DC 7 CURRENT RATING (AMPERES) 12 AGENCY APPROVAL CODE AMPERES T UL489A LISTED 210 0.100 285 0.850 455 5.500 613 13.000 J UL489A LISTED, TUV CERTIFIED 215 0.150 290 0.900 460 6.000 614 14.000 220 0.200 295 0.950 465 6.500 615 15.000 Notes: 225 0.250 410 1.000 470 7.000 616 16.000 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 230 0.300 512 1.250 475 7.500 617 17.000 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or 235 0.350 415 1.500 480 8.000 618 18.000 mixed poles, and have one rocker per breaker. 240 0.400 517 1.750 485 8.500 620 20.000 3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 245 0.450 420 2.000 490 9.000 622 22.000 30-50A are supplied with extended boat (B-Style) half shells. 250 0.500 522 2.250 495 9.500 624 24.000 4 VDE Certification available with single pole breakers only. UL489A Listing available with one 255 0.550 527 2.750 610 10.000 625 25.000 and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps 260 0.600 430 3.000 710 10.500 630 30.000 4 are only available with Terminal Codes 5, 9, G, H, M and Q. 265 0.650 435 3.500 611 11.000 635 35.000 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 4 270 0.700 440 4.000 711 11.500 640 40.000 amps with UL489A Listing, but is not recommended over 20 amps. 4 275 0.750 445 4.500 612 12.000 645 45.000 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and 4 280 0.800 450 5.000 712 12.500 650 50.000 Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 20 A-Series Rocker – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. 4 Circuits shown for >30 amps / VDE. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Rocker – Form & Fit Drawings 21 Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ± 0.20 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 22 A-Series Rocker Snap-In Bracket – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. Orientation on indicate “OFF” is opposite of indicate “ON” 3 Recommended panel thickness: .04 0 [1.02] to .100 [2.54] 4 All dimensions are in Inches [millimeters]. 5 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | A-Series Flat Rocker – Form & Fit Drawings 23 Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ± 0.20 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 24 A-Series PC Terminal Diagrams Notes: 1 Drawing illustrates A-Series with VDE certification. 2 All dimensions are in inches [millimeters]. 3 Tolerance ± 0.20 [.51] unless otherwise specified REV_CB_A_0712 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the AK2-B0-26-620-1C3-D?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Manufacturers


What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods