CARLING TECHNOLOGIES BB2-B0-34-640-421-E
Description
Circuit Breaker 2Pole 40A
B-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; max interrupting capacity of 5,000A. Tongue & groove half shelf constructions. Front panel mount. Available w/ choice of time delays & terminals w/ handle & rocker actuators. See datasheet.
Part Number
BB2-B0-34-640-421-E
Price
Request Quote
Manufacturer
CARLING TECHNOLOGIES
Lead Time
Request Quote
Category
Circuit Protection » Circuit Breaker
Specifications
Manufacturer
Carling Technologies
Manufacturers Part #
BB2-B0-34-640-421-E
Industry Aliases
BB2-B0-34-640-421-E
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
B-Series – General Specifications Designed specifically for world market applications, the B-series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments. Typical applications include power supplies, medical equipment, office equipment, control panels and marine equipment. In addi- tion, these breakes meet CSA Standard 22.2 No. 100 for the Generator & Welder markets. 1-6 poles, 0.02 - 50 amps, up to 277 VAC or 80 VDC, with choice of time delays, terminals and actuator colors. Agency Certifications UL Recognized CSA Accepted Component Supplementary UL Standard 1077 Component Recognition Program Protector under Class 3215 30, as Protectors Supplementary FIle 047848 0 000 CSA (Guide CCN/QVNU2, File E75596) Standard C22.2 No. 235 TUV Certified EN60934, under License No. UL Standard 508 Switches, Industrial Control R72040875 (Guide CCN/NRNT2, File E148683) UL Standard 1500 Protectors, Supplementary for VDE Certified EN60934, VDE 0642 under File No. Marine Electrical & Fuel Systems 10537 (Guide PEQZ2, File E75596) Ignition Protection UL Listed UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E189195) UL Standard 489A Communications Equipment (Guide CCN/DITT, File E189195) www.carlingtech.com 57 B-Series – General Specifications Electrical Table A: Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary Protector. Notes for Table A: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80A maximum. 3 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System. 58 www.carlingtech.com B-Series – General Specifications Electrical Table B: Lists UL Recognized, CSA, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. Notes for Table B: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 1, except that backup fuse is limited to 80 A maximum. Table C: Lists UL Recognized, CSA Certified configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (CCN/Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (CCN/Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Notes for Table C: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System. Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (CCN/Guide DITT, File E189195), under UL489A Notes for Table D: 1 60 -90 amp ratings require parallel pole construction www.carlingtech.com 59 B-Series – General Specifications Electrical Mechanical Maximum Voltage 277VAC 50/60 Hz, 80VDC Endurance 10,000 ON-OFF operations @ 6 per Current Ratings Standard current coils: 0.100, 0.250, minute; with rated Current and 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, Voltage. 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, Trip Free All B-Series Circuit Breakers will trip 40.0 and 50.0 amps. Other ratings on overload, even when Handle is available, see ordering scheme. forcibly held in the ON position. Standard Voltage Coils DC - 6V, 12V; AC - 120V, other rat- Trip Indication The operating Handle moves posi- ings available, see ordering scheme. tively to the OFF position when an Auxiliary Switch Rating SPDT; 10.1 AMPS - 250VAC,1.0A overload causes the breaker to trip. 65 VDC or 0.5A 80 VDC, 0.1 Amps - Physical 125VAC (with gold contacts). VDE-1.0 Amp - 125VAC. Insulation Resistance Minimum of 100 Megohms at 500 Number of Poles 1 - 6 poles at 30 Amps or less. 1 VDC. and 2 poles at 31 Amps thru 50 Dielectric Strength UL, CSA - 1500 V 50/60 Hz for one Amps. minute between all electrically isolat- Internal Circuit Config. Series, (with or without auxiliary ed terminals. B-Series circuit break- switch), Shunt and Relay with cur- ers comply with the 8mm spacing rent or voltage trip coils, Dual Coil, and 3750V 50/60 Hz dielectric Switch Only (with or without auxiliary requirements from hazardous volt- switch). age to operator accessible surfaces, Weight Approximately 65 grams/pole. between adjacent poles and from (Approximately 2.32 ounces/pole.) main circuits to auxiliary circuits per Standard Colors Housing- Black; Actuator - See Publications EN 60950 and VDE Ordering Scheme. 0805. Environmental Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Designed and tested in accordance with requirements of specifi- cation MIL-PRF- 55629 and MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition "I". Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060" excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% Pulse Tolerance Curves RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C 60 www.carlingtech.com B-Series Handle UL Recognized – Ordering Scheme 10 450 B 3 – –– – 1 – A B 0 B 1 C 8 1 3 4 5 6 7 9 10 11 2 Mounting/ Series Poles Aux/Alarm Current Rating Terminal Actuator Agency Actuator Circuit Frequency Barriers Switch Approval & Delay Color 7 CURRENT RATING (AMPERES) 1 SERIES B 020 0.020 230 0.300 425 2.500 612 12.000 025 0.025 235 0.350 527 2.750 712 12.500 1 030 0.030 240 0.400 430 3.000 613 13.000 2 ACTUATOR 035 0.035 245 0.450 435 3.500 614 14.000 A Handle, one per pole 040 0.040 250 0.500 440 4.000 615 15.000 B Handle, one per multipole unit 045 0.045 255 0.550 445 4.500 616 16.000 S Mid-Trip Handle, one per pole 050 0.050 260 0.600 450 5.000 617 17.000 T Mid-Trip Handle, one per pole & Alarm Switch 055 0.055 265 0.650 455 5.500 618 18.000 060 0.060 270 0.700 460 6.000 620 20.000 3 POLES 065 0.065 275 0.750 465 6.500 622 22.000 1 One 3 Three 5 Five 070 0.070 280 0.800 470 7.000 624 24.000 2 Two 4 Four 6 Six 075 0.075 285 0.850 475 7.500 625 25.000 080 0.080 290 0.900 480 8.000 630 30.000 3 8 4 CIRCUIT G Relay Trip (Voltage) 085 0.085 295 0.950 485 8.500 635 35.000 2 3,4 8 A Switch Only (No Coil) H Dual Coil with Shunt Trip 090 0.090 410 1.000 490 9.000 640 40.000 8 B Series Trip (Current) Voltage Coil 095 0.095 512 1.250 495 9.500 645 45.000 8 3,4 C Series Trip (Voltage) J Dual Coil with Shunt Trip 210 0.100 415 1.500 610 10.000 650 50.000 3 215 0.150 517 1.750 710 10.500 D Shunt Trip (Current) Voltage Coil (side terminal) 3 3,4 220 0.200 420 2.000 611 11.000 E Shunt Trip (Voltage) K Dual Coil with Relay Trip 3 225 0.250 522 2.250 711 11.500 F Relay Trip (Current) Voltage Coil 6 OR VOLTAGE COIL (NOMINAL RATED VOLTAGE) A06 6 DC A32 32 DC J12 12 AC J65 65 AC 5 5 AUXILIARY/ALARM SWITCH 5 S.P.S.T., 0.093 Q.C. A12 12 DC A48 48 DC J18 18 AC K20 120 AC 0 w/o Aux Switch Term.(Gold Contacts) A18 18 DC A65 65 DC J24 24 AC L40 240 AC 1 S.P.D.T., 0.093 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug A24 24 DC J06 6 AC J48 48 AC 2 S.P.D.T., 0.110 Q.C. Term. 7 S.P.S.T., 0.110 Q.C. 9 11 8 TERMINAL E Screw M4 (Bus Type) 3 S.P.D.T., 0.139 Solder Lug Term.(Gold Contacts) 10 1 Push-On 0.250 Tab (Q.C.) F Screw M5 w/upturned lugs 4 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. 2 Screw 8-32 w/upturned lugs and 30° bend (Gold Contacts) 9 S.P.D.T., 0.187 Q.C. Term. 11 3 Screw 8-32 (Bus Type) G Screw M5 (Bus Type) 4 Screw 10-32 w/upturned lugs and 30° bend 6 FREQUENCY & DELAY 11 5 Screw 10-32 (Bus Type) H Screw M5 (Bus Type) 2 03 DC 50/60Hz, Switch Only 30 DC, 50/60Hz Instantaneous 12 6 Screw 8-32 w/upturned lugs L 0.250 Q.C./ Solder Lug 6 10 DC Instantaneous 31 DC, 50/60Hz Ultra Short 11 and 30° bend M M6 Threaded Studs 11 DC Ultra Short 32 DC, 50/60Hz Short 13 7 Screw 8-32 (Bus Type) and P Printed Circuit Board 12 DC Short 34 DC, 50/60Hz Medium 30° bend Terminals 14 DC Medium 36 DC, 50/60Hz Long 16 8 Screw 10-32 w/upturned lugs Q Push-In Stud 7 16 DC Long 42 50/60Hz Short, Hi-Inrush and 30° bend R Screw M4 w/upturned lugs 6 7 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 9 Screw 10-32 (Bus Type) and and 30° bend 7 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 15 30° bend S Push-On 0.110 Tab (Q.C.) 7 22 50/60Hz Short 52 DC, Short,Hi-Inrush B Screw M5 w/upturned lugs T Screw M4 (Bus Type) 7 24 50/60Hz Medium 54 DC, Medium, Hi-Inrush C Screw M4 w/upturned lugs and 30° bend 7 26 50/60Hz Long 56 DC, Long, Hi-Inrush Notes: 9 ACTUATOR COLOR & LEGEND 1 Actuator Code: I-O ON-OFF Dual Legend Color A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. WhiteAB1 Black B: Handle location as viewed from front of breaker: BlackCD2 White 2 pole - left pole 3 pole - center pole RedFG 3 White 4 pole - two handles at center poles 5 pole - three handles at center poles GreenHJ 4 White 6 pole - four handles at center poles BlueKL 5 White S: Handle moves to mid-position only upon electrical trip of the breaker. Available with cir- YellowMN 6 Black cuit codes B, C, D, E, F, G, H and K. GrayPQ 7 Black T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the OrangeRS 8 Black breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 10 MOUNTING/BARRIERS amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. MOUNTING STYLE BARRIERS 3 Available with Terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. Threaded Insert, 2 per pole 4 Consult factory for available Dual Coil options, as special catalog number is required. 1 6-32 x 0.195 inches no With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils A 6-32 X 0.195 inches (multi-pole units only) yes require 30VA minimum power to trip and are rated for intermittent duty only. 2 ISO M3 x 5mm no 5 Auxiliary Switch breakers with Series Trip and Switch Only circuits. On multi-pole break- B ISO M3 x 5mm yes ers, one aux. switch is supplied, mounted in the extreme right pole. Rectangular Adapter Plate with mounting centers of 2.062” 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay [52.37mm] and Threaded insert, 2 per pole codes 10 and 20. 14 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized and 3 6-32 x 0.225 inches no 14 CSA Accepted to 50 amps. C 6-32 X 0.225 inches (multi-pole units only) yes 14 8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition 4 ISO M3 x 6.5mm no 14 and CSA Accepted available in one and two pole breakers. D ISO M3 x 6.5mm yes 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 Front panel Snap-In, 0.75” [19.05mm] wide bezel amps are only available with Terminal Codes 5, 9, G, H, M and Q. 5 without Handleguard no 10 VDE Certification up to 25 amps and UL Recognition and CSA Acceptance up to 30 6 without Handleguard (multi-pole units only) yes amps, but not recommended over 20 amps. Front panel Snap-In, 0.96” [24.48mm] wide bezel 11 Terminal Codes 3, 5 E and H (Bus Type) with VDE, are supplied with Lock Washers, and 7 without Handleguard, 1-pole units 0.96” wide; no Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. multipole units have .105“ bezel overhang on all sides These breakers are only VDE Certified when the washers are used. 8 without Handleguard, 1-pole units 0.96” wide; yes 12 VDE Cert. available up to 12 amps. UL Rec. & CSA Acceptance available up to 30 amps. (multi-pole units only) .105“ bezel overhang on all sides 13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Acceptance, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit 11 AGENCY APPROVAL Board) are available up to 40 amps with UL Recognition and CSA Acceptance with Circuit C UL Recognized & CSA Accepted Codes A, B and C. D VDE Certified, UL Recognized & CSA Accepted 14 Available with Actuator Codes A, S and T. E TUV Certified, UL Recognized & CSA Accepted 15 Available with voltage coils only. I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted 16 Terminal Code Q not available with VDE approvals. www.carlingtech.com 61 B-Series Handle UL489A – Ordering Scheme – 14 450 – B 1 –– 1 T A – B 0 B 1 M 8 12 1 3 4 5 6 7 9 10 11 2 Mounting/ Agency Series Poles Aux/Alarm Current Rating Terminal Actuator Max. Appl. Actuator Circuit Frequency Barriers Switch Rating Approval & Delay Color 4 1 SERIES 8 TERMINAL 9 Screw 10-32 (Bus Type) and 5 B 1 Push-On 0.250 Tab (Q.C.) 30° bend 2 Screw 8-32 w/upturned lugs B Screw M5 w/upturned lugs 6 1 3 Screw 8-32 (Bus Type) F Screw M5 w/upturned lugs 2 ACTUATOR 4 Screw 10-32 w/upturned lugs and 30° bend A Handle, one per pole 6 G Screw M5 (Bus Type) B Handle, one per multipole unit 5 Screw 10-32 (Bus Type) and 30° bend S Mid-Trip Handle, one per pole 6 Screw 8-32 w/upturned lugs H Screw M5 (Bus Type) T Mid-Trip Handle, one per pole & Alarm Switch and 30° bend 6 M M6 Threaded Stud 7 Screw 8-32 (Bus Type) and 7 P Printed Circuit Board 30° bend 3 POLES Terminals 1 One 2 Two 3 Three 4 Four 8 Screw 10-32 w/upturned lugs 8 Q Push-In Stud and 30° bend 4 CIRCUIT B Series Trip (Current) 9 ACTUATOR COLOR LEGEND 2 5 AUXILIARY/ALARM SWITCH ON-OFF Dual Legend Color 0 w/o Aux Switch 7 S.P.S.T., 0.110 Q.C. White B1 Black 1 S.P.D.T., 0.093 Q.C. Term. Term.(Gold Contacts) Black D2 White 2 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. Red G3 White 3 S.P.D.T., 0.139 Solder Lug 9 S.P.D.T., 0.187 Q.C. Term. Green J4 White Blue L5 White 4 Yellow N6 Black 6 FREQUENCY & DELAY Gray Q7 Black 11 DC Ultra Short 52 DC, Short,Hi-Inrush Orange S8 Black 12 DC Short 54 DC, Medium, Hi-Inrush 14 DC Medium 56 DC, Long, Hi-Inrush 10 MOUNTING/BARRIERS 16 DC Long MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole 7 CURRENT RATING (AMPERES) 1 6-32 x 0.195 inches no 210 0.100 415 1.500 710 10.500 A 6-32 X 0.195 inches (multi-pole units only) yes 215 0.150 517 1.750 611 11.000 2 ISO M3 x 5mm no 220 0.200 420 2.000 711 11.500 B ISO M3 x 5mm (multi-pole units only) yes Rectangular Adapter Plate with mounting centers of 2.062 inches 225 0.250 522 2.250 612 12.000 and Threaded insert, 2 per pole 230 0.300 527 2.750 712 12.500 3 6-32 x 0.225 inches no 235 0.350 430 3.000 613 13.000 C 6-32 X 0.225 inches (multi-pole units only) yes 240 0.400 435 3.500 614 14.000 4 ISO M3 x 6.5mm no 245 0.450 440 4.000 615 15.000 D ISO M3 x 6.5mm (multi-pole units only) yes 250 0.500 445 4.500 616 16.000 Front panel Snap-In, 0.75” wide bezel 255 0.550 450 5.000 617 17.000 5 without Handleguard no 260 0.600 455 5.500 618 18.000 6 without Handleguard (multi-pole units only) yes 265 0.650 460 6.000 620 20.000 Front panel Snap-In, 0.96” wide bezel 270 0.700 465 6.500 622 22.000 7 without Handleguard, 1-pole units 0.96” wide; no 275 0.750 470 7.000 624 24.000 multipole units have .105“ bezel overhang on all sides 8 without Handleguard, 1-pole units 0.96” wide; yes 280 0.800 475 7.500 625 25.000 (multi-pole units only).105“ bezel overhang on all sides 285 0.850 480 8.000 630 30.000 3 290 0.900 485 8.500 635 35.000 3 11 MAXIMUM APPLICATION RATING 295 0.950 490 9.000 640 40.000 3 M 80 DC 410 1.000 495 9.500 645 45.000 3 512 1.250 610 10.000 650 50.000 12 AGENCY APPROVAL T UL489A Listed K UL489A Listed, VDE Certified Notes: J UL489A Listed, TUV Certified 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 4 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 5 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 6 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with TUV or VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 7 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 8 Terminal Code Q not available with VDE approvals. 62 www.carlingtech.com B-Series Handle UL489 Listed – Ordering Scheme – – – – – B A 1 B 0 24 450 1 B A K G 1 2 3 4 5 6 7 8 9 10 11 12 Mounting/ Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Max. Appl. Agency Barriers Switch & Delay Color Rating Approval 5 1 SERIES 8 TERMINAL 9 Screw 10-32 (Bus Type) and B 1 Push-On 0.250 Tab (Q.C.) 30° bend 2 Screw 8-32 w/upturned lugs A Load Terminal: #8 Screw/QC 1 3 Screw 8-32 (Bus Type) Combination. (Special Cat.#) 2 ACTUATOR 4 Screw 10-32 w/upturned lugs B Screw M5 w/upturned lugs A Handle, one per pole 5 Screw 10-32 (Bus Type) F Screw M5 w/upturned lugs B Handle, one per mulit-pole unit 6 Screw 8-32 w/upturned lugs and 30° bend S Mid-Trip Handle, one per pole G Screw M5 (Bus Type) and 30° bend T Mid-Trip Handle, one per pole & Alarm Switch and 30° bend 7 Screw 8-32 (Bus Type) and H Screw M5 (Bus Type) 30° bend 2 3 POLES M M6 Threaded Stud 8 Screw 10-32 w/upturned lugs 3 1 One 2 Two 3 Three Q Push-In Stud and 30° bend 4 CIRCUIT 6 9 ACTUATOR COLOR B Series Trip (Current) LEGEND ON-OFF Dual Legend Color 4 5 AUXILIARY/ALARM SWITCH White B1 Black 0 w/o Aux Switch 3 S.P.D.T., 0.139 Solder Lug Black D2 White 1 S.P.D.T., 0.093 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. Red G3 White 2 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. Green J4 White Blue L5 White 6 FREQUENCY & DELAY Yellow N6 Black 21 AC Ultra Short 42 AC, Short,Hi-Inrush Gray Q7 Black 22 AC Short 44 AC, Medium, Hi-Inrush Orange S8 Black 24 AC Medium 46 AC, Long, Hi-Inrush 26 AC Long 10 MOUNTING/BARRIERS 9 MOUNTING STYLE BARRIERS 7 CURRENT RATING (AMPERES) Threaded Insert, 2 per pole A 6-32 X 0.195 inches yes 210 0.100 512 1.250 495 9.500 B ISO M3 x 5mm yes 215 0.150 415 1.500 610 10.000 Rectangular Adapter Plate with mounting centers of 2.062 inches 220 0.200 517 1.750 710 10.500 7 and Threaded insert, 2 per pole 225 0.250 420 2.000 611 11.000 C 6-32 X 0.225 inches yes 230 0.300 522 2.250 711 11.500 D ISO M3 x 6.5mm yes 235 0.350 527 2.750 612 12.000 Front panel Snap-In, 0.75” wide bezel 240 0.400 430 3.000 712 12.500 6 without Handleguard yes 245 0.450 435 3.500 613 13.000 Front panel Snap-In, 0.96” wide bezel 250 0.500 440 4.000 614 14.000 8 without Handleguard, 1-pole units 0.96” wide; yes 255 0.550 445 4.500 615 15.000 .105“ bezel overhang on all sides 260 0.600 450 5.000 616 16.000 265 0.650 455 5.500 617 17.000 11 MAXIMUM APPLICATION RATING 8 270 0.700 460 6.000 618 18.000 C 120/240VAC 275 0.750 465 6.500 620 20.000 K 120VAC 280 0.800 470 7.000 622 22.000 285 0.850 475 7.500 624 24.000 12 AGENCY APPROVAL 290 0.900 480 8.000 625 25.000 G UL489 Listed 295 0.950 485 8.500 630 30.000 3 UL489 Listed, TUV Certified 410 1.000 490 9.000 Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole S: Handle moves to mid-position only upon electrical trip of the breaker. Available with cir- cuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 All poles must be same polarity. 3 3 pole units available only when 1 of 3 poles is neutral. 4 Auxiliary/Alarm Switch circuit must be same polarity as the main circuit. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 5 Screw Terminals are recommended on ratings greater than 20 amps. 6 Standard actuator colors are black and white. 7 Adapter plate with mounting centers of 2.082 inches. Available with Actuator Codes A, S and T. 8 Voltage Rating available with 2 and 3-pole breakers only. 9 Barriers supplied on multi-pole units only. www.carlingtech.com 63 B-Series Rocker UL489 Listed – Ordering Scheme 24 630 – – – – B F 1 B – 2 3 A G 0 K 8 12 1 2 3 4 5 6 7 9 10 11 Terminal Mounting/ Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Actuator Max. Appl. Barriers Approval Switch Color Rating & Delay 1 SERIES 7 CURRENT RATING (AMPERES) B 210 0.100 280 0.800 445 4.500 711 11.500 215 0.150 285 0.850 450 5.000 612 12.000 220 0.200 290 0.900 455 5.500 712 12.500 2 ACTUATOR Push-To-Reset, Visi-Rocker 225 0.250 295 0.950 460 6.000 613 13.000 N Indicate OFF, Two Color Visi-Rocker 230 0.300 410 1.000 465 6.500 614 14.000 vertical legend C Indicate ON, 235 0.350 512 1.250 470 7.000 615 15.000 O Indicate OFF, vertical legend 240 0.400 415 1.500 475 7.500 616 16.000 horizontal legend D Indicate ON, 245 0.450 517 1.750 480 8.000 617 17.000 horizontal legend Push-To-Reset , Single color 250 0.500 420 2.000 485 8.500 618 18.000 F Indicate OFF, R Vertical legend 255 0.550 522 2.250 490 9.000 620 20.000 vertical legend 260 0.600 527 2.750 495 9.500 622 22.000 U Horizontal legend G Indicate OFF, 265 0.650 430 3.000 610 10.000 624 24.000 horizontal legend 270 0.700 435 3.500 710 10.500 625 25.000 275 0.750 440 4.000 611 11.000 630 30.000 Single color J Vertical legend 5 K Horizontal legend 8 TERMINAL 6 1 Push-On 0.250 Tab (Q.C.) 9 Screw 10-32 (Bus Type) and 2 Screw 8-32 w/upturned lugs 30° bend 3 Screw 8-32 (Bus Type) B Screw M5 w/upturned lugs 4 Screw 10-32 w/upturned lugs C Screw M4 w/upturned lugs 5 Screw 10-32 (Bus Type) F Screw M5 w/upturned lugs 6 Screw 8-32 w/upturned lugs and 30° bend and 30° bend G Screw M5 (Bus Type) 7 Screw 8-32 (Bus Type) and and 30° bend 1,2 3 POLES 3 30° bend H Screw M5 (Bus Type) 1 One 2 Two 3 Three 8 Screw 10-32 w/upturned lugs and 30° bend 4 CIRCUIT B Series Trip (Current) 9 ACTUATOR COLOR & LEGEND Actuator or 7 4 Visi-Color Marking Marking Color: 5 AUXILIARY/ALARM SWITCH 7 0 w/o Aux Switch 7 S.P.S.T., 0.110 Q.C. ON-OFF Dual Single Color Visi-Rocker 1 S.P.D.T., 0.093 Q.C. Term. Term.(Gold Contacts) White B1 Black White 2 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. Black D2 White n/a 3 S.P.D.T., 0.139 Solder Lug 9 S.P.D.T., 0.187 Q.C. Term. Red G3 White Red Green J4 White Green Blue L5 White Blue 6 FREQUENCY & DELAY Yellow N6 Black Yellow 21 AC Ultra Short 42 AC, Short,Hi-Inrush Gray Q7 Black Gray 22 AC Short 44 AC, Medium, Hi-Inrush Orange S8 Black Orange 24 AC Medium 46 AC, Long, Hi-Inrush 26 AC Long 10 MOUNTING/BARRIERS 9 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole A 6-32 X 0.195 inches yes B ISO M3 x 5mm yes ROCKERGUARD BEZEL Threaded Insert, 2 per pole C 6-32 x 0.195 inches yes D ISO M3 x 5mm yes 11 MAXIMUM APPLICATION RATING 8 C 120/240 VAC Notes: K 120 VAC 1 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 2 All poles must be same polarity. 11 AGENCY APPROVAL 3 3 pole units available only when1 of 3 poles is neutral. G UL489 Listed 4 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 5 Screw Terminals are recommended on ratings greater than 20 amps. 6 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 20 amps. 7 Dual legend = ON-OFF/I-O 8 Voltage Rating available with 2 and 3-pole breakers only. 9 Barriers supplied on multi-pole units only. 64 www.carlingtech.com B-Series Flat Rocker UL489 Listed – Ordering Scheme 24 630 – – – – B 1 1 B – 2 3 A G 0 K 8 12 1 2 3 4 5 6 7 9 10 11 Terminal Mounting/ Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Actuator Max. Appl. Barriers Approval Switch Color Rating & Delay 1 SERIES 7 CURRENT RATING (AMPERES) B 210 0.100 280 0.800 445 4.500 711 11.500 215 0.150 285 0.850 450 5.000 612 12.000 1 220 0.200 290 0.900 455 5.500 712 12.500 2 ACTUATOR 225 0.250 295 0.950 460 6.000 613 13.000 Two Color Visi-Rocker 230 0.300 410 1.000 465 6.500 614 14.000 1 Indicate OFF, vertical legend 235 0.350 512 1.250 470 7.000 615 15.000 2 Indicate OFF, horizontal legend 240 0.400 415 1.500 475 7.500 616 16.000 Single color 245 0.450 517 1.750 480 8.000 617 17.000 3 Vertical legend 250 0.500 420 2.000 485 8.500 618 18.000 255 0.550 522 2.250 490 9.000 620 20.000 4 Horizontal legend 260 0.600 527 2.750 495 9.500 622 22.000 Push-To-Reset, Visi-Rocker 265 0.650 430 3.000 610 10.000 624 24.000 5 Indicate OFF, vertical legend 270 0.700 435 3.500 710 10.500 625 25.000 6 Indicate OFF, horizontal legend 275 0.750 440 4.000 611 11.000 630 30.000 Push-To-Reset , Single color 7 Vertical legend 6 8 TERMINAL 8 Horizontal legend 7 1 Push-On 0.250 Tab (Q.C.) 9 Screw 10-32 (Bus Type) and 2 Screw 8-32 w/upturned lugs 30° bend 2,3 3 POLES 3 Screw 8-32 (Bus Type) B Screw M5 w/upturned lugs 4 1 One 2 Two 3 Three 4 Screw 10-32 w/upturned lugs C Screw M4 w/upturned lugs 5 Screw 10-32 (Bus Type) F Screw M5 w/upturned lugs 4 CIRCUIT 6 Screw 8-32 w/upturned lugs and 30° bend and 30° bend G Screw M5 (Bus Type) B Series Trip (Current) 7 Screw 8-32 (Bus Type) and and 30° bend 30° bend H Screw M5 (Bus Type) 5 5 AUXILIARY/ALARM SWITCH 8 Screw 10-32 w/upturned lugs 0 w/o Aux Switch 7 S.P.S.T., 0.110 Q.C. and 30° bend 1 S.P.D.T., 0.093 Q.C. Term. Term.(Gold Contacts) 2 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. 9 ACTUATOR COLOR & LEGEND 3 S.P.D.T., 0.139 Solder Lug 9 S.P.D.T., 0.187 Q.C. Term. Actuator or 8 Visi-Color Marking Marking Color: 8 ON-OFF Dual Single Color Visi-Rocker 6 FREQUENCY & DELAY White B1 Black White 21 AC Ultra Short 42 AC, Short,Hi-Inrush Black D2 White n/a 22 AC Short 44 AC, Medium, Hi-Inrush Red G3 White Red 24 AC Medium 46 AC, Long, Hi-Inrush Green J4 White Green 26 AC Long Blue L5 White Blue Yellow N6 Black Yellow Gray Q7 Black Gray Orange S8 Black Orange 9 12 10 MOUNTING/BARRIERS BARRIERS STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR A 6-32 X 0.195 inches yes B ISO M3 x 5mm yes 10 RECESSED OFF SIDE ROCKER ACTUATOR E 6-32 x 0.195 inches yes F ISO M3 x 5mm yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole C 6-32 x 0.195 inches yes D ISO M3 x 5mm yes 11 MAXIMUM APPLICATION RATING 11 Notes: C 120/240 VAC 1 Push-To-Reset actuators have OFF portion of rocker shrouded. K 120 VAC 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 All poles must be same polarity. 12 AGENCY APPROVAL 4 3 pole units available only when1 of 3 poles is neutral. G UL489 Listed 5 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 6 Screw Terminals are recommended on ratings greater than 20 amps. 7 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 20 amps. 8 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O leg- end. 9 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 10 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. 11 Voltage rating available with 2 & 3-pole breakers only. 12 Barriers supplied on multi-pole units only. www.carlingtech.com 65 B-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. 66 www.carlingtech.com B-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 67 B-Series Handle – Front Panel Snap-In Mounting Style 5 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 68 www.carlingtech.com B-Series Handle – Front Panel Snap-in Mounting Style 5 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 69 B-Series Handle – Front Panel Snap-In Mounting Style 7 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. 70 www.carlingtech.com B-Series PC Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ±.010 [.25] unless otherwise specified. www.carlingtech.com 71 B-Series Rocker UL489 Listed – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate “OFF” is opposite of indicate “ON”. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 72 www.carlingtech.com B-Series Flat Rocker UL489 Listed – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 73
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the BB2-B0-34-640-421-E?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Manufacturers


What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods