CARLING TECHNOLOGIES BB3-X0-07-274-121-D
Specifications
Manufacturer
Carling Technologies
Manufacturers Part #
BB3-X0-07-274-121-D
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
B-S B-Series eries CIRCUIT BREAKER Carling Technologies’ B-Series hydraulic magnetic circuit breakers are specifically designed for applications requiring extra insulation and tongue and groove half-shell constructions. The B-Series carries global regulatory safety approvals for spacing requirements and are ideal for use as general purpose as well as full load amp applications. Available with various choices of time delays, terminals, actuator styles, with a wide range of standard colors and imprinting. 1-6 poles; ratings from 0.02 to 50 amps, up to 277VAC or 80VDC; UL recognized, CSA, VDE -0642, TUV, UL-1500, UL489A Listed Product Highlights: Typical Applications: Meet CSA Standard 22.2 No. 100 for the Power Supplies Generator & Welder markets Medical Equipment Extra insulation and tongue & groove half-shell Generators & Welders constructions Office Equipment UL Recognized - UL Standard 508, 1077, 1500 Control Panels UL Listed - UL Standard 489, 489A Marine CSA Accepted Military TUV Certified VDE Certified Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com www.carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 | B-Series Circuit Breaker - General Specifications 2 Electrical Mechanical Maximum Voltage 277VAC 50/60 Hz, 80VDC Endurance 10,000 ON-OFF operations @ 6 per Current Ratings Standard current coils: 0.100, minute; with rated Current and 0.250, 0.500, 0.750, 1.00, 2.50, Voltage. 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, Trip Free All B-Series Circuit Breakers will 30.0, 35.0, 40.0 and 50.0 amps. trip on overload, even when Handle Other ratings available, see is forcibly held in the ON position. ordering scheme. Trip Indication The operating Handle moves Standard Voltage Coils DC - 6V, 12V; AC - 120V, other positively to the OFF position when ratings available, see ordering an overload causes the breaker to scheme. trip. Auxiliary Switch Rating SPDT; 10.1 AMPS - 250VAC,1.0A 65 VDC or 0.5A 80 VDC, 0.1 Amps Physical - 125VAC (with gold contacts). Number of Poles 1 - 6 poles at 30 Amps or less. 1 VDE-1.0 Amp - 125VAC. and 2 poles at 31 Amps thru 50 Insulation Resistance Minimum of 100 Megohms at 500 Amps. VDC. Internal Circuit Config. Series, (with or without auxiliary Dielectric Strength UL, CSA-1500 V 50/60 Hz for one switch), Shunt and Relay with minute between all electrically current or voltage trip coils, Dual isolated terminals. B-Series circuit Coil, Switch Only (with or without breakers comply with the 8mm auxiliary switch). spacing and 3750V 50/60 Hz Weight Approximately 65 grams/pole. dielectric requirements from (Approximately 2.32 ounces/pole.) hazardous voltage to operator Standard Colors Housing- Black; Actuator - See accessible surfaces, between Ordering Scheme. adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE Environmental 0805. Resistance, Impedance Values from Line to Load Terminal Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: - based on Series Trip Circuit Breaker. RESISTANCE PER POLE VALUES Shock Withstands 100 Gs, 6ms, sawtooth from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) while carrying rated current per Method 213, Test Condition “I”. CURRENT TOLERANCE Instantaneous and ultra-short (AMPS) (%) curves tested @ 90% of rated current. 0.10 - 5.0 15 Vibration Withstands 0.060” excursion from 5.1 - 20.0 25 10-55 Hz, and 10 Gs 55-500 Hz, 20.1 - 50.0 35 at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% Pulse Tolerance Curves RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com B-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary Protector. Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80A maximum. 3 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System. 4 Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 4 B-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 1, except that backup fuse is limited to 80 A maximum. Table C: Lists UL Recognized, CSA Certified configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (CCN/Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (CCN/Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Notes: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com B-Series Circuit Breaker - General Specifications | 5 Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (CCN/ Guide DITT, File E189195), under UL489A Notes: 1 Parallel Pole Construction Table E: Lists UL Listed (489) configuration and performance capabilities as a Molded Case Circuit Breaker. B SERIES TABLE E : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE INTERRUPTING CURRENT RATING CAPACITY (AMPS) CIRCUIT CONSTRUCTION NOTES CONFIGURATION MAX. RATING FREQUENCY PHASE WITHOUT BACKUP FULL LOAD AMPS FUSE 120 50 / 60 1 0.10 - 30 5,000 1 Pole SERIES 2 Poles 120 / 240 50 / 60 1 0.10 - 30 5,000 120 / 240 50 / 60 1 0.10 - 30 5,000 2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break) 120 50 / 60 1 0.10 - 30 5,000 1 Pole SHUNT TRIP 2 Poles 120 / 240 50 / 60 1 0.10 - 30 5,000 DUAL COIL 2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break) 120 / 240 50 / 60 1 0.10 - 30 5,000 Agency Certifications UL Recognized CSA Accepted Component Supplementary Component Recognition Program Protector under Class 3215 30, UL Standard 1077 as Protectors Supplementary FIle 047848 0 000 CSA (Guide CCN/QVNU2, File E75596) Standard C22.2 No. 235 UL Standard 508 Switches, Industrial Control TUV Certified EN60934, under License No. (Guide CCN/NRNT2, File E148683) R72103448 UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems VDE Certified EN60934, VDE 0642 under File (Guide PEQZ2, File E75596) No. 10537 Ignition Protection UL Listed UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) Communications Equipment UL Standard 489A (Guide CCN/DITT, File E189195) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 6 B-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme B A 3 B 0 10 450 1 B 1 C 1 2 3 4 5 6 7 8 9 10 11 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Agency Color Barriers Approval Switch & Delay 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES B 020 0.020 225 0.250 420 2.000 611 11.000 025 0.025 230 0.300 522 2.250 711 11.500 030 0.030 235 0.350 527 2.750 612 12.000 2 ACTUATOR 035 0.035 240 0.400 430 3.000 712 12.500 A Handle, one per pole 040 0.040 245 0.450 435 3.500 613 13.000 B Handle, one per multipole unit 045 0.045 250 0.500 440 4.000 614 14.000 S Mid-Trip Handle, one per pole 050 0.050 255 0.550 445 4.500 615 15.000 T Mid-Trip Handle, one per pole & Alarm Switch 055 0.055 260 0.600 450 5.000 616 16.000 060 0.060 265 0.650 455 5.500 617 17.000 065 0.065 270 0.700 460 6.000 618 18.000 3 POLES 070 0.070 275 0.750 465 6.500 620 20.000 1 One 3 Three 5 Five 075 0.075 280 0.800 470 7.000 622 22.000 2 Two 4 Four 6 Six 080 0.080 285 0.850 475 7.500 624 24.000 085 0.085 290 0.900 480 8.000 625 25.000 090 0.090 295 0.950 485 8.500 630 30.000 4 CIRCUIT 8 095 0.095 410 1.000 490 9.000 635 35.000 2 3 A Switch Only (No Coil) G Relay Trip (Voltage) 8 210 0.100 512 1.250 495 9.500 640 40.000 3,4 B Series Trip (Current) H Dual Coil with Shunt Trip 8 215 0.150 415 1.500 610 10.000 645 45.000 C Series Trip (Voltage) Voltage Coil 8 220 0.200 517 1.750 710 10.500 650 50.000 3 3,4 D Shunt Trip (Current) K Dual Coil with Relay Trip 6 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 3 E Shunt Trip (Voltage) Voltage Coil CODE AMPERES 3 F Relay Trip (Current) A06 6 DC A32 32 DC J12 12 AC J65 65 AC A12 12 DC A48 48 DC J18 18 AC K20 120 AC A18 18 DC A65 65 DC J24 24 AC L40 240 AC 5 5 AUXILIARY / ALARM SWITCH A24 24 DC J06 6 AC J48 48 AC 0 without Aux Switch 7 S.P.S.T., 0.110 Q.C. Term. 2 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 9 4 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. 8 TERMINAL F Screw M5 with upturned lugs 10 (Gold Contacts) 9 S.P.D.T., 0.187 Q.C. Term. 1 Push-On 0.250 Tab (Q.C.) & 30° bend 2 Screw 8-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend 11 3 Screw 8-32 (Bus Type) H Screw M5 (Bus Type) 4 Screw 10-32 with upturned lugs J Screw M5 Back Connect 6 FREQUENCY & DELAY 11 5 Screw 10-32 (Bus Type) K Screw 10-32 Back Connect 2 03 DC 50/60Hz, Switch Only 30 DC, 50/60Hz Instantaneous 12 6 Screw 8-32 with upturned lugs L 0.250 Q.C./ Solder Lug 6 10 DC Instantaneous 31 DC, 50/60Hz Ultra Short 11 & 30° bend M M6 Threaded Stud 11 DC Ultra Short 32 DC, 50/60Hz Short 7 Screw 8-32 (Bus Type) N Screw M4 Back Connect 12 DC Short 34 DC, 50/60Hz Medium 13 & 30° bend P Printed Circuit Board Terminals 14 DC Medium 36 DC, 50/60Hz Long 16 8 Screw 10-32 with upturned lugs Q Push-In Stud 7 16 DC Long 42 50/60Hz Short, Hi-Inrush & 30° bend R Screw M4 with upturned lugs 6 7 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 9 Screw 10-32 (Bus Type) & 30° bend 7 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 15 & 30° bend S Push-On 0.110 Tab (Q.C.) 7 22 50/60Hz Short 52 DC, Short,Hi-Inrush B Screw M5 with upturned lugs & 30° bend 7 24 50/60Hz Medium 54 DC, Medium, Hi-Inrush C Screw M4 with upturned lugs T Screw M4 (Bus Type) & 30° bend 7 11 26 50/60Hz Long 56 DC, Long, Hi-Inrush E Screw M4 (Bus Type) Y Screw 8-32 Back Connect Notes: 9 ACTUATOR COLOR & LEGEND 1 Actuator Code: Actuator Color I-O ON-OFF Dual Legend Color A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. White A B 1 Black B: Handle location as viewed from front of breaker: Black C D 2 White 2 pole - left pole 3 pole - center pole Red F G 3 White 4 pole - two handles at center poles 5 pole - three handles at center poles Green H J 4 White 6 pole - four handles at center poles Blue K L 5 White S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit Yellow M N 6 Black codes B, C, D, E, F, G, H and K. Gray P Q 7 Black T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the Orange R S 8 Black breaker. Available with circuit codes B & C. 2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, 10 MOUNTING / BARRIERS select Current Code 630. For 35 - 50 amps, select Current Code 650. MOUNTING STYLE BARRIERS 3 Available with Terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. Threaded Insert, 2 per pole 4 Consult factory for available Dual Coil options, as special catalog number is required. With 1 6-32 x 0.195 inches no Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require A 6-32 x 0.195 inches (multi-pole units only) yes 30VA minimum power to trip and are rated for intermittent duty only. 2 ISO M3 x 5mm no 5 Auxiliary Switch breakers with Series Trip and Switch Only circuits. On multi-pole breakers, B ISO M3 x 5mm yes one auxiliary switch is supplied, mounted in the extreme right pole. Rectangular Adapter Plate with mounting centers of 2.062 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay inches [52.37mm] and Threaded insert, 2 per pole codes 10 and 20. 14 3 6-32 x 0.225 inches no 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized and 14 C 6-32 X 0.225 inches (multi-pole units only) yes CSA Accepted to 50 amps. 14 4 ISO M3 x 6.5mm no 8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition 14 D ISO M3 x 6.5mm yes and CSA Accepted available in one and two pole breakers. Front panel Snap-In, 0.75” [19.05mm] wide bezel 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps 5 without Handleguard no are only available with Terminal Codes 5, 9, G, H, J, K, M and Q. 6 without Handleguard (multipole only) yes 10 VDE Certification up to 25 amps and UL Recognition and CSA Acceptance up to 30 amps, Front panel Snap-In, 0.96” wide bezel but not recommended over 20 amps. 7 without Handleguard, 1-pole 0.96” wide; no 11 Terminal Codes 3, 5 E and H (Bus Type) with VDE, are supplied with Lock Washers, and multipole units have .105” bezel overhang on all sides Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. 8 without Handleguard, 1-pole 0.96” wide; yes These breakers are only VDE Certified when the washers are used. (multipole only) .105” bezel overhang on all sides 12 VDE Cert. available up to 12 amps. UL Rec. & CSA Acceptance available up to 30 amps. 13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Acceptance, with 11 AGENCY APPROVAL Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) C UL Recognized & CSA Accepted are available up to 40 amps with UL Recognition and CSA Acceptance with Circuit Codes D VDE Certified, UL Recognized & CSA Accepted A, B and C. E TUV Certified, UL Recognized & CSA Accepted 14 Available with Actuator Codes A, S and T. I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), 15 Available with voltage coils only. & CSA Accepted 16 Terminal Code Q not available with VDE approvals. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com B-Series Circuit Breaker - Handle UL489A – Ordering Scheme | 7 B A 1 B 0 14 450 1 B 1 M T 4 8 9 10 11 12 1 2 3 5 6 7 Terminal Actuator Mounting/ Max. Appl. Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Switch & Delay Color Barriers Rating Approval 1 SERIES 9 ACTUATOR COLOR & LEGEND B Actuator Color ON-OFF Dual Legend Color White B 1 Black Black D 2 White 1 2 ACTUATOR Red G 3 White A Handle, one per pole Green J 4 White B Handle, one per multipole unit Blue L 5 White S Mid-Trip Handle, one per pole Yellow N 6 Black T Mid-Trip Handle, one per pole & Alarm Switch Gray Q 7 Black Orange S 8 Black 2 3 POLES 1 One 3 Three 10 MOUNTING / BARRIERS 2 Two 4 Four MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no 4 CIRCUIT A 6-32 x 0.195 inches (multi-pole units only) yes B Series Trip (Current) 2 ISO M3 x 5mm no B ISO M3 x 5mm yes Rectangular Adapter Plate with mounting centers of 2.062 2 5 AUXILIARY / ALARM SWITCH inches [52.37mm] and Threaded insert, 2 per pole 0 without Aux Switch 8 S.P.S.T., 0.187 Q.C. Term. 3 6-32 x 0.225 inches no 2 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. C 6-32 X 0.225 inches (multi-pole units only) yes 3 S.P.D.T., 0.110 Solder Lug 4 ISO M3 x 6.5mm no 7 S.P.S.T., 0.110 Q.C. Term. D ISO M3 x 6.5mm yes (Gold Contacts) Front panel Snap-In, 0.75” [19.05mm] wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes 4 Front panel Snap-In, 0.96” wide bezel 6 FREQUENCY & DELAY 7 without Handleguard, 1-pole 0.96” wide; no 11 DC Ultra Short 52 DC, Short,Hi-Inrush multipole units have .105” bezel overhang on all sides 12 DC Short 54 DC, Medium, Hi-Inrush 8 without Handleguard, 1-pole 0.96” wide; yes 14 DC Medium 56 DC, Long, Hi-Inrush (multipole only) .105” bezel overhang on all sides 16 DC Long 11 MAXIMUM APPLICATION RATING 7 CURRENT RATING (AMPERES) CODE AMPERES M 80 DC 210 0.100 285 0.850 455 5.500 613 13.000 215 0.150 290 0.900 460 6.000 614 14.000 12 AGENCY APPROVAL 220 0.200 295 0.950 465 6.500 615 15.000 225 0.250 410 1.000 470 7.000 616 16.000 T UL489A Listed 230 0.300 512 1.250 475 7.500 617 17.000 K UL489A Listed, VDE Certified 235 0.350 415 1.500 480 8.000 618 18.000 J UL489A Listed, TUV Certified 240 0.400 517 1.750 485 8.500 620 20.000 245 0.450 420 2.000 490 9.000 622 22.000 250 0.500 522 2.250 495 9.500 624 24.000 Notes: 255 0.550 527 2.750 610 10.000 625 25.000 1 Actuator Code: 260 0.600 430 3.000 710 10.500 630 30.000 A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. 3 S: Handle moves to mid-position only upon electrical trip of the breaker. 265 0.650 435 3.500 611 11.000 635 35.000 3 T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the 270 0.700 440 4.000 711 11.500 640 40.000 breaker. 3 275 0.750 445 4.500 612 12.000 645 45.000 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 280 0.800 450 5.000 712 12.500 650 50.000 3 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 4 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps 4 8 TERMINAL are only available with Terminal Codes 5, 9, G, H, J, K, M and Q. 5 5 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 1 Push-On 0.250 Tab (Q.C.) B Screw M5 with upturned lugs 30 amps with UL489A Listing, but is not recommended over 20 amps. 2 Screw 8-32 with upturned lugs F Screw M5 with upturned lugs 6 6 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, 3 Screw 8-32 (Bus Type) & 30° bend and Terminal Code M (M6 Threaded Stud) with TUV or VDE is supplied with Lock and 4 Screw 10-32 with upturned lugs G Screw M5 (Bus Type) & 30° bend Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 6 5 Screw 10-32 (Bus Type) H Screw M5 (Bus Type) 7 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 6 Screw 8-32 with upturned lugs J Screw M5 Back Connect amps with VDE Certification and 50 amps with UL489A Listing. & 30° bend K Screw 10-32 Back Connect 8 Terminal Code Q not available with VDE approvals. 6 7 Screw 8-32 (Bus Type) M M6 Threaded Stud & 30° bend N Screw M4 Back Connect 7 8 Screw 10-32 with upturned lugs P Printed Circuit Board Terminals 8 & 30° bend Q Push-In Stud 9 Screw 10-32 (Bus Type) Y Screw 8-32 Back Connect & 30° bend Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 8 B-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme B A 1 B 0 24 450 1 B A K G 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. Appl. Agency Switch & Delay Color Barriers Rating Approval 6 1 SERIES 9 ACTUATOR COLOR & LEGEND Actuator Color ON-OFF Dual Legend Color B White B 1 Black Black D 2 White 1 2 ACTUATOR Red G 3 White A Handle, one per pole Green J 4 White B Handle, one per multipole unit Blue L 5 White S Mid-Trip Handle, one per pole Yellow N 6 Black T Mid-Trip Handle, one per pole & Alarm Switch Gray Q 7 Black Orange S 8 Black 2 3 POLES 3 1 One 2 Two 3 Three 10 MOUNTING / BARRIERS MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole 4 CIRCUIT A 6-32 x 0.195 inches (multi-pole units only) yes B Series Trip (Current) B ISO M3 x 5mm yes Rectangular Adapter Plate with mounting centers of 2.062 7 inches [52.37mm] and Threaded insert, 2 per pole 4 5 AUXILIARY / ALARM SWITCH C 6-32 X 0.225 inches (multi-pole units only) yes 0 without Aux Switch 8 S.P.S.T., 0.187 Q.C. Term. D ISO M3 x 6.5mm yes 2 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. Front panel Snap-In, 0.75” [19.05mm] wide bezel 3 S.P.D.T., 0.110 Solder Lug 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 8 without Handleguard, 1-pole 0.96” wide; yes 6 FREQUENCY & DELAY (multipole only) .105” bezel overhang on all sides 21 AC Ultra Short 42 AC, Short,Hi-Inrush 22 AC Short 44 AC, Medium, Hi-Inrush 24 AC Medium 46 AC, Long, Hi-Inrush 11 MAXIMUM APPLICATION RATING 26 AC Long 8 C 120/240VAC K 120VAC 7 CURRENT RATING (AMPERES) CODE AMPERES 12 AGENCY APPROVAL 210 0.100 280 0.800 445 4.500 711 11.500 215 0.150 285 0.850 450 5.000 612 12.000 G UL489 Listed 220 0.200 290 0.900 455 5.500 712 12.500 3 UL489 Listed, TUV Certified 225 0.250 295 0.950 460 6.000 613 13.000 230 0.300 410 1.000 465 6.500 614 14.000 Notes: 235 0.350 512 1.250 470 7.000 615 15.000 1 Actuator Code: 240 0.400 415 1.500 475 7.500 616 16.000 A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. 245 0.450 517 1.750 480 8.000 617 17.000 B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 250 0.500 420 2.000 485 8.500 618 18.000 S: Handle moves to mid-position only upon electrical trip of the breaker. Available with 255 0.550 522 2.250 490 9.000 620 20.000 circuit codes B, C, D, E, F, G, H and K. 260 0.600 527 2.750 495 9.500 622 22.000 T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the 265 0.650 430 3.000 610 10.000 624 24.000 breaker. Available with circuit codes B & C. 270 0.700 435 3.500 710 10.500 625 25.000 2 All poles must be same polarity. 275 0.750 440 4.000 611 11.000 630 30.000 3 3 pole units available only when 1 of 3 poles is neutral. 4 Auxiliary/Alarm Switch circuit must be same polarity as the main circuit. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 4 5 Screw Terminals are recommended on ratings greater than 20 amps. 8 TERMINAL A Load Terminal #8 Screw with QC 6 Standard actuator colors are black and white. 1 Push-On 0.250 Tab (Q.C.) Combination (Special Catalog #) 7 Adapter plate with mounting centers of 2.082 inches. Available with Actuator 2 Screw 8-32 with upturned lugs B Screw M5 with upturned lugs Codes A, S and T. 3 Screw 8-32 (Bus Type) F Screw M5 with upturned lugs 8 Voltage Rating available with 2 and 3-pole breakers only. 4 Screw 10-32 with upturned lugs & 30° bend 9 Barriers supplied on multi-pole units only. 5 Screw 10-32 (Bus Type) G Screw M5 (Bus Type) & 30° bend 6 Screw 8-32 with upturned lugs H Screw M5 (Bus Type) & 30° bend J Screw M5 Back Connect 7 Screw 8-32 (Bus Type) K Screw 10-32 Back Connect & 30° bend M M6 Threaded Stud 8 Screw 10-32 with upturned lugs N Screw M4 Back Connect & 30° bend Q Push-In Stud 9 Screw 10-32 (Bus Type) Y Screw 8-32 Back Connect & 30° bend Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com ON I ON I ON I B-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams | 9 Circuit & Terminal Diagrams: in. [mm] CIRCUIT SCHEMATIC CIRCUIT SCHEMATIC ANSI IEC ANSI IEC SWITCH ONLY (NO COIL) SERIES TRIP SERIES TRIP LINE LINE LINE (3) (2 TERM'S.) LINE (NETZ) (NETZ) MAIN TERM'S. A O B O (SEE TABLE A) C I > LOAD 1.730 [43.94] LOAD LOAD (LAST) LOAD (LAST) SERIES TRIP WITH SWITCH ONLY (NO COIL) .520 [13.21] AUXILIARY / ALARM SWITCH WITH AUXILIARY SWITCH LINE LINE (NETZ) (3) STD. AUX. SWITCH STD. AUX. SWITCH SERIES TRIP LINE LINE (NETZ) W AUX SWITCH C (5 TERM'S.) C C C C NO NO NO A 2 B 2 NC NO NO 3 C 3 4 4 NC I > NC NC NC ALARM SWITCH ALARM SWITCH AUX. SWITCH LOAD (LAST) LOAD LOAD LOAD (LAST) TERM'S. SHUNT TRIP DUAL COIL; SERIES TRIP CURRENT COIL, SHUNT TRIP VOLTAGE COIL LINE LINE (NETZ) (3) LINE (NETZ) LINE SHUNT TRIP (3 TERM'S.) SHUNT (NEBENSCHLUSS) D 0 H 0 SHUNT E VOLTAGE I > U > I > COIL LOAD VOLTAGE .390 [9.91] LOAD LOAD (LAST) LOAD (LAST) COIL RELAY TRIP DUAL COIL; SERIES TRIP CURRENT COIL, RELAY TRIP VOLTAGE COIL LINE RELAY LINE (3) LINE LINE VOLTAGE 1 (RELAIS) (NETZ) 1 RELAY TRIP .780 [19.81] (NETZ) COIL 3 1 1 (4 TERM'S.) 1 2 2 2 2 LOAD F 0 K 0 G RELAY VOLTAGE I > U > I > 3 3 3 COIL 4 4 2 3 4 4 4 LOAD VOLTAGE RELAY LOAD (RELAIS) (LAST) (LAST) COIL .390 [9.91] RELAY LOAD HANDLEPOSITIONVS.AUX/ALARMSWITCHMODE STANDARD C/B MID TRIP C/B MID TRIP C/B CIRCUIT BREAKER HANDLE POSITION AUX. SWITCH MODE HANDLE POSITION ALARM SWITCH MODE HANDLE POSITION AUX. SWITCH MODE MODE (w/o ALARM SWITCH) 30° 30° 30° OFF NC NO C NC NO C NC NO C ON 30° 30° 30° NC NO C NC NO C NC NO C 30° 90° 90° MID MID TRIP TRIP ELECTRICAL TRIP NC NO C NC NO C NC NO C Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com OFF O OFF O OFF O OFF O CIRCUIT CODE AUX SWITCH CODE CIRCUIT CODE AUX SWITCH CODE | 10 B-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] 1.000 [25.40] TERMINAL DIMENSIONAL DETAIL & RATING .392 [9.97] .205 [5.21] CENTERLINE OF PUSH-IN .360[9.14] .392[9.96] .392[9.96] .344[8.74] .750[19.05] STUD CONTACT AREA .250[6.35] .375[9.53] .375[9.53] .100 [2.54] .250[6.35] .405[10.29] .069[1.75] DIA .437 [11.10] .154 [3.91] DIA .093DIA [.76] .750 [19.05] TAB (Q.C.) QC SOLDER LUG UPTURN LUG BUS BACK CONNECT M6 STUD PUSH-IN STUD #8-32 30 AMP #8-32 30 AMP 30 AMP #8-32 30 AMP 50 AMP 50 AMP 30 AMP #10-32 30 AMP #10-32 50 AMP #10-32 50 AMP M5 50 AMP M5 30 AMP M4 30 AMP M4 30 AMP AUXILIARY SWITCH TERMINAL DETAIL +.002 [+.05] TABLE A -.000 [-.00] .110 [2.80] .110 [2.80] TIGHTENING TORQUE .161 DIA [Ø 4.10] .051 DIA[Ø1.29] SPECIFICATIONS THREAD SIZE TORQUE #6-32 & M3 MOUNTING 7-9 IN-LBS .087 [2.20] [0.8-1.0 NM] HARDWARE PUSH-IN STUD .287 [7.29] .126 [3.20] .070 DIA [Ø1.80] #8-32 & M4 THREAD 12-15 IN-LBS MATING HOLE TERMINAL SCREW [1.4-1.7 NM] 15-20 IN-LBS #10-32 & M5 THREAD TERMINAL SCREW [1.7-2.3 NM] TAB (Q.C.) SOLDER TYPE 2.230 [56.64] TYP 1.313 [33.35] .520 [13.21] TABLE B LINE DEPTH TERMINAL DESCRIPTION BEHIND PANEL LINE TAB (Q.C.) 2.090 [53.09] MAIN SCREW TYPE 2.122 [53.90] 2.000 [50.80] SHUNT, RELAY TAB (Q.C.) 2.612 [66.35] & SCREW #8-32 2.644 [67.16] DUAL COIL W/UPTURNED LUGS LOAD TAB (Q.C.) .110 x .020 2.537 [64.44] LOAD AUX. SWITCH* SOLDER TYPE 2.348 [59.64] * AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS. .875 [22.23] REF WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITCH IS NORMALLY SUPPLIED, AS SHOWN IN MULTI-POLE BARRIER FOR BARRIER FOR IDENTIFICATION SCHEME. UL-489 MULTI-POLE UL-RECOGNIZED MULTI-POLE BREAKERS BREAKERS SEE TABLE-B .393 [9.96] REF DEPTH BEHIND PANEL ON LINE I (NETZ) MID TRIP 1.560 [39.62] TYP 30° 1.936[49.17] 1.350 [34.29] 2 PLCS OFF O 1.560 [39.62] TYP LOAD (LAST) .032 [.81] TYP PUSH-IN SCREW TERMINAL M6 STUD STUD WITH 30° BEND .220 [5.59] TYP 1.250 [31.75] BACK CONNECT BACK CONNECT SCREW TERMINAL SCREW TERMINAL WITH RETAINER Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com B-Series Circuit Breaker - Handle - Dimensional Specifications | 11 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 12 B-Series Circuit Breaker - Handle – Front Panel Snap-in Mounting Style 5 - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com B-Series Circuit Breaker - Handle – Front Panel Snap-In Mounting Style 7 - Dimensional Specifications | 13 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 14 B-Series Circuit Breaker - Rocker UL489 Listed – Ordering Scheme B F 1 B 0 24 630 2 3 A K G 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. Appl. Agency Color Barriers Rating Approval Switch & Delay 5 1 SERIES 8 TERMINAL 6 1 Push-On 0.250 Tab (Q.C.) B Screw M5 with upturned lugs B 2 Screw 8-32 with upturned lugs C Screw M4 with upturned lugs 3 Screw 8-32 (Bus Type) F Screw M5 with upturned lugs 4 Screw 10-32 with upturned lugs & 30° bend 2 ACTUATOR 5 Screw 10-32 (Bus Type) G Screw M5 (Bus Type) & 30° bend Two Color Visi-Rocker Single color 6 Screw 8-32 with upturned lugs H Screw M5 (Bus Type) C Indicate ON, vertical legend J Vertical legend & 30° bend J Screw M5 Back Connect D Indicate ON, horizontal legend K Horizontal legend 7 Screw 8-32 (Bus Type) K Screw 10-32 Back Connect F Indicate OFF, vertical legend & 30° bend N Screw M4 Back Connect G Indicate OFF, horizontal legend 8 Screw 10-32 with upturned lugs Y Screw 8-32 Back Connect & 30° bend 9 Screw 10-32 (Bus Type) & 30° bend 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color 7 7 Visi-Color ON-OFF Dual Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 10 MOUNTING / BARRIERS 1,2 3 POLES 9 3 MOUNTING STYLE BARRIERS 1 One 2 Two 3 Three Threaded Insert, 2 per pole A 6-32 x 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm yes 4 CIRCUIT B Series Trip (Current) ROCKERGUARD BEZEL Threaded Insert, 2 per pole C 6-32 X 0.225 inches (multi-pole units only) yes 4 5 AUXILIARY / ALARM SWITCH D ISO M3 x 6.5mm yes 0 without Aux Switch 7 S.P.S.T., 0.110 Q.C. Term. 1 S.P.D.T., 0.093 Q.C. Term. (Gold Contacts) 2 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. 11 MAXIMUM APPLICATION RATING 3 S.P.D.T., 0.110 Solder Lug 9 S.P.D.T., 0.187 Q.C. Term. 8 C 120/240 VAC K 120 VAC 6 FREQUENCY & DELAY 21 AC Ultra Short 42 AC, Short,Hi-Inrush 12 AGENCY APPROVAL 22 AC Short 44 AC, Medium, Hi-Inrush G UL489 Listed 24 AC Medium 46 AC, Long, Hi-Inrush 3 UL489 Listed, TUV Certified 26 AC Long Notes: 1 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 7 CURRENT RATING (AMPERES) 2 All poles must be same polarity. CODE AMPERES 3 3 pole units available only when 1 of 3 poles is neutral. 020 0.020 220 0.200 415 1.500 495 9.500 4 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 025 0.025 225 0.250 517 1.750 610 10.000 5 Screw Terminals are recommended on ratings greater than 20 amps. 030 0.030 230 0.300 420 2.000 710 10.500 6 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 035 0.035 235 0.350 522 2.250 611 11.000 20 amps. 040 0.040 240 0.400 527 2.750 711 11.500 7 Dual legend = ON-OFF/I-O 045 0.045 245 0.450 430 3.000 612 12.000 8 Voltage Rating available with 2 and 3-pole breakers only. 050 0.050 250 0.500 435 3.500 712 12.500 9 Barriers supplied on multi-pole units only. 055 0.055 255 0.550 440 4.000 613 13.000 060 0.060 260 0.600 445 4.500 614 14.000 065 0.065 265 0.650 450 5.000 615 15.000 070 0.070 270 0.700 455 5.500 616 16.000 075 0.075 275 0.750 460 6.000 617 17.000 080 0.080 280 0.800 465 6.500 618 18.000 085 0.085 285 0.850 470 7.000 620 20.000 090 0.090 290 0.900 475 7.500 622 22.000 095 0.095 295 0.950 480 8.000 624 24.000 210 0.100 410 1.000 485 8.500 625 25.000 215 0.150 512 1.250 490 9.000 630 30.000 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com B-Series Circuit Breaker - Flat Rocker UL489 Listed – Ordering Scheme | 15 B 1 1 B 0 24 630 2 3 A K G 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. Appl. Agency Color Barriers Rating Approval Switch & Delay 6 1 SERIES 8 TERMINAL 7 B 1 Push-On 0.250 Tab (Q.C.) B Screw M5 with upturned lugs 2 Screw 8-32 with upturned lugs C Screw M4 with upturned lugs 3 Screw 8-32 (Bus Type) F Screw M5 with upturned lugs 1 4 Screw 10-32 with upturned lugs & 30° bend 2 ACTUATOR 5 Screw 10-32 (Bus Type) G Screw M5 (Bus Type) & 30° bend Two Color Visi-Rocker Push-To-Reset, Visi-Rocker 6 Screw 8-32 with upturned lugs H Screw M5 (Bus Type) 1 Indicate OFF, vertical legend 5 Indicate OFF, vertical legend & 30° bend J Screw M5 Back Connect 2 Indicate OFF, horizontal legend 6 Indicate OFF, horizontal legend 7 Screw 8-32 (Bus Type) K Screw 10-32 Back Connect Single color Push-To-Reset , Single color & 30° bend N Screw M4 Back Connect 3 Vertical legend 7 Vertical legend 8 Screw 10-32 with upturned lugs Y Screw 8-32 Back Connect 4 Horizontal legend 8 Horizontal legend & 30° bend 9 Screw 10-32 (Bus Type) & 30° bend 9 ACTUATOR COLOR & LEGEND Actuator or Marking: Marking Color 8 8 Visi-Color ON-OFF Dual Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange 9 10 MOUNTING / BARRIERS 12 2,3 STANDARD ROCKER BEZEL BARRIERS 3 POLES 4 Threaded Insert, 2 per pole 1 One 2 Two 3 Three FLAT ROCKER ACTUATOR A 6-32 x 0.195 inches (multi-pole units only) yes 4 CIRCUIT B ISO M3 x 5mm yes 10 B Series Trip (Current) RECESSED OFF SIDE ROCKER ACTUATOR E 6-32 X 0.225 inches (multi-pole units only) yes F ISO M3 x 6.5mm yes 4 5 AUXILIARY / ALARM SWITCH PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 0 without Aux Switch 7 S.P.S.T., 0.110 Q.C. Term. C 6-32 x 0.195 inches yes 1 S.P.D.T., 0.093 Q.C. Term. (Gold Contacts) D ISO M3 x 5mm yes 2 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. 3 S.P.D.T., 0.110 Solder Lug 9 S.P.D.T., 0.187 Q.C. Term. 11 MAXIMUM APPLICATION RATING 11 C 120/240 VAC 6 FREQUENCY & DELAY K 120 VAC 21 AC Ultra Short 42 AC, Short,Hi-Inrush 22 AC Short 44 AC, Medium, Hi-Inrush 24 AC Medium 46 AC, Long, Hi-Inrush 12 AGENCY APPROVAL 26 AC Long G UL489 Listed 3 UL489 Listed, TUV Certified 7 CURRENT RATING (AMPERES) Notes: CODE AMPERES 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 020 0.020 220 0.200 415 1.500 495 9.500 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or 025 0.025 225 0.250 517 1.750 610 10.000 mixed poles, and have one rocker per breaker. 030 0.030 230 0.300 420 2.000 710 10.500 3 All poles must be same polarity. 035 0.035 235 0.350 522 2.250 611 11.000 4 3 pole units available only when1 of 3 poles is neutral. 040 0.040 240 0.400 527 2.750 711 11.500 5 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 045 0.045 245 0.450 430 3.000 612 12.000 6 Screw Terminals are recommended on ratings greater than 20 amps. 7 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 050 0.050 250 0.500 435 3.500 712 12.500 20 amps. 055 0.055 255 0.550 440 4.000 613 13.000 8 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 060 0.060 260 0.600 445 4.500 614 14.000 9 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. 065 0.065 265 0.650 450 5.000 615 15.000 Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 070 0.070 270 0.700 455 5.500 616 16.000 5 & 6. 075 0.075 275 0.750 460 6.000 617 17.000 10 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available 080 0.080 280 0.800 465 6.500 618 18.000 in ink stamping only. 085 0.085 285 0.850 470 7.000 620 20.000 11 Voltage rating available with 2 & 3-pole breakers only. 090 0.090 290 0.900 475 7.500 622 22.000 12 Barriers supplied on multi-pole units only. 095 0.095 295 0.950 480 8.000 624 24.000 210 0.100 410 1.000 485 8.500 625 25.000 215 0.150 512 1.250 490 9.000 630 30.000 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 16 B-Series Circuit Breaker - Rocker UL489 Listed - Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate “OFF” is opposite of indicate “ON”. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com B-Series Circuit Breaker - Flat Rocker UL489 Listed - Dimensional Specifications | 17 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ±.010 [.25] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 18 B-Series Circuit Breaker - PC Terminal Diagrams PC Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ±.010 [.25] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Sales Representatives, Distributors & Company Profile | 19 Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. CANADA EUROPE USA MIDDLE EAST MEXICO AFRICA ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 @ Email: sales carlingtech.com @ Northern Region Sales Office: nrsm carlingtech.com @ Southeast Region Sales Office: sersm carlingtech.com @ Midwest Region Sales Office: mrsm carlingtech.com @ West Region Sales Office: wrsm carlingtech.com @ Latin America Sales Office: larsm carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Suite 1607, 16/F Tower 2, The Gateway, Harbour City, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 @ Email: sales carlingtech.com.hk @ Shenzhen, China: shenzhen carlingtech.com @ Shanghai, China: shanghai carlingtech.com @ Pune, India: india carlingtech.com @ Kaohsiung, Taiwan: taiwan carlingtech.com @ Yokohama, Japan: japan carlingtech.com | | Europe Middle East Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 @ Email: ltd.sales carlingtech.com @ Germany: gmbh carlingtech.com @ France: sas carlingtech.com www.carlingtech.com REV_04_2018
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the BB3-X0-07-274-121-D?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Manufacturers



What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods