CARLING TECHNOLOGIES CA3X023363121D

Description

Carling Technologies

Part Number

CA3X023363121D

Price

Request Quote

Manufacturer

CARLING TECHNOLOGIES

Lead Time

Request Quote

Category

Circuit Protection »  Circuit Breaker

Specifications

Manufacturer

Carling Technologies

Manufacturers Part #

CA3X023363121D

Industry Aliases

CA3X023363121D

Sub-Category

Circuit Breakers

Factory Pack Quantity

1

Datasheet

pdf file

C-Series_Details_%26_COS_040314.pdf

3107 KiB

Extracted Text

C-S C-Series eries CIRCUIT BREAKER The C-Series hydraulic-magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal options, actuator styles and colors. The C-Series employs a unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps. Thermoset glass filled polyester half shell construction provides for increased mechanical and electrical strength. The wiping contacts mechanical linkage, with two step actuation, cleans contacts providing high, positive contact pressure and longer contact life. Available with American Standard or Metric Threaded Stud terminals, or Saddle Clamp screw terminals. The optional mid-trip handle style actuator allows a visual indication of electrical overload with or without alarm feature. Product Highlights: Typical Applications: Š Extensive list of Agency Approvals Š Marine Š Available with Standard or Metric Stud terminals, Š Telecom/Datacom or Saddle Clamp screw terminals Š Military Š Optional mid-trip handle style actuator Š Renewable Energy Š Unique arc chute design which allows for higher Š Generators & Welders interrupting capacities of up to 10,000 amps Š Exclusive Rockerguard and Push-To-Reset bezel Š Available with new solid color and two-color Visi- rocker® actuators Š New thermoset glass filled polyester half shell construction Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com www.carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 | C-Series Circuit Breaker - General Specifications 2 Electrical Mechanical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz Endurance 10,000 ON-OFF operations @ 6 per (see Table A.) minute; with rated current & UL489: AC,240 VAC. (See Table D), voltage. 50/60 Hz, 125 VDC Trip Free All C-Series circuit breakers will trip Current Rating Standard current coils: 0.100, on overload, even when actuator is 0.250, 0.500, 0.750, 1.00, 2.50, forcibly held in the ON position. 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, Trip Indication The operating actuator moves 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, positively to the OFF position when 90.0 and 100 amps. Other ratings an overload causes the breaker to available, see Ordering Scheme. trip. With mid-trip, handle moves to Standard Voltage Coils DC - 6V, 12V; AC - 120V; other the mid position on electrical trip of ratings available, see Ordering the circuit breaker. With mid trip Scheme. handle with alarm switch, handle Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux. moves to the mid position and the Switch 1.0A, 65 VDC. 0.5A, alarm switch actuates when the 80VDC,1/4 HP, 125VAC,VDE & TUV circuit breaker is electrically 1.0 125 VAC. tripped. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Physical Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one Number of Poles 1-6 poles ≤ 50A; 1-4 poles @ 51- minute between all electrically 70A; 1-2 poles 71-100A. UL489 isolated terminals. C-Series Circuit Handle: 1 pole ≤ 100A, 2 pole ≤ Breakers comply with the 8mm 50A; Rocker: 1 pole ≤ 100A. spacing and 3750V 50/60 Hz Internal Circuit Config. Series (with or without auxiliary dielectric requirements from switch, mid trip & mid trip with hazardous voltage to operator alarm switch) Shunt & Relay with accessible surfaces, between current or voltage trip coils, Dual adjacent poles and from main Coil, Switch Only (with or without circuits to auxiliary circuits per aux. switch). UL489: Series (with or Publications EN 60950 and without auxiliary switch, mid-trip & VDE 0805. midtrip with alarm switch). Resistance, Impedance Values from Line to Load Terminal - Weight Approx.112 grams/pole ( 3.95 oz). based on Series Trip Circuit Standard Colors Housing: Black RESISTANCE, IMPEDANCE VALUES Breaker. from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Environmental 1000 CURRENT TOLERANCE Designed and tested in accordance with requirements of (AMPS) (%) 100 specification MIL-PRF-55629 & MIL-STD-202 as follows: 0.10 - 5.0 15 Shock Withstands 100 Gs, 6ms sawtooth 10 while carrying rated current per 5.1 - 20.0 25 O Method 213, Test Condition “I”. H 1 20.1 - 50.0 35 M Instantaneous and ultrashort curves S 60 Hz 1/2 Cycle Inrush Pulse Tolerance 0.1 tested @ 90% of rated current. I r Time Delay Curves 42, 44 & 46 Vibration Withstands 0.060” excursion from (50 Amps Max.) 25x 0.01 10-55 Hz & 10 Gs 55-500 Hz, @ Time Delay Curves 22, 24 (100 Amps Max.) 12x 26 (70 Amps Max.) rated current per Method 204C, 0.001 0.01 0.1 1 10 100 t Test Cond. A. Instantaneous & AMPERE RATING 8.33 4.165 16.67 ultrashort curves tested @ 90% of CURRENT TOLERANCE (AMPS) (%) Pulse Tolerance Curves rated current. 0.100 - 5.0 15% 5.1 - 20.0 25% 60 Hz 1/2 Cycle 50 Hz 1/2 Cycle Moisture Resistance Method 106D, i.e., ten 24-hour 20.1 - 100 35% Inrush Pulse Tolerance Inrush Pulse Tolerance I I r r FIGURE 1 Time Delay Curves Time Delay Curves cycles @ +25°C to +65°C, 42, 44 & 46 22x 42, 44 & 46 (50 Amps Max.) (50 Amps Max.) 25x 80-98% RH. Time Delay Curves Time Delay Curves 10x 22, 24 (100 Amps Max.) 22, 24 (100 Amps Max.) 12x 26 (70 Amps Max.) 26 (70 Amps Max.) Salt Spray Method 101, Condition A (90-95% t t 10.0 20.0 RH @ 5% NaCl Solution, 96 hrs). 5.0 8.33 4.165 16.67 Time in Thermal Shock Method 107D, Condition A (five Milliseconds cycles @ -55°C to +25°C to +85°C 50 Hz 1/2 Cycle Inrush Pulse Tolerance I r to +25°C). Time Delay Curves 22x 42, 44 & 46 (50 Amps Max.) Operating Temperature -40°C to +85°C Time Delay Curves 10x 22, 24 (100 Amps Max.) 26 (70 Amps Max.) t 10.0 20.0 5.0 *Manufacturer reserves the right to change product specification without prior notice. Time in Milliseconds Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Multiple of Multiple of Rated Current Rated Current Multiple of Multiple of Rated Current Rated Current C-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a component supplementary protector C-SERIES TABLE A: Component Supplementary Protectors Short Circuit Voltage Current Rating Application Codes Capacity (Amps) Circuit UL / CSA Full General Construction Notes Configuration Max. With Without Frequency Phase Load Purpose UL CSA Rating Backup Backup Amps Amps Fuse Fuse 32 DC --- 0.02 - 100 --- --- 5,000 --- TC1, OL1, U2 TC1, OL1, U2 48 DC --- 110 - 150 --- --- 5,000 --- 0.02 - 70 --- TC1, 2, OL1, U1 TC1, 2, OL1, U1 --- 65 DC --- --- 5,000 - 71 - 100 TC1, 2, OL0, U1 TC1, 2, OL0, U1 --- 0.02 - 70 --- TC1, 2, OL1, U1 TC1, 2, OL1, U1 --- 7,500 --- 71 - 100 TC1, 2, OL0, U1 TC1, 2, OL0, U1 --- 80 DC --- --- 0.02 - 70 --- TC1, 2, OL1, U1 TC1, 2, OL1, U1 10,000 Must have Agency "L" --- 71 - 100 TC1, 2, OL0, U1 TC1, 2, OL0, U1 125 DC --- 0.02 - 50 --- --- 5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Must have Agency "L" 125/250 DC --- 0.02 - 50 --- --- 5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Must have Agency "L" 250 DC --- 0.02 - 50 --- --- 5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Must have Agency "L". 250 volts requires 2 pole --- 3,000 TC1, OL1, U2 TC1, OL1, U2 Per pole rating 125 50 / 60 1 0.02 - 100 --- --- 5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Must have Agency "L" 80 - 100 Must have Agency "L" 150 DC --- --- --- 5,000 TC1, 2, OL0, U3 --- 101 - 175 Must have Agency "L" parallel pole Series 0.02 - 100 3,500 TC1, OL1, U2 TC1, OL1, U2 --- 0.02 - 50 3,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 2 or 3 poles breaking single phase 125/250 50 / 60 1 --- --- 51 - 100 1,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 2 or 3 poles breaking single phase 0.02 - 100 5,000 TC1, 2, OL1, U2 TC1, 2, OL1, U2 2 or 3 poles breaking single phase. Agency "L" 0.02 - 50 3,500 TC1, 2, OL1, U2 TC1, 2, OL1, U2 Per pole rating --- 1 0.02 - 100 --- 5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Must have Agency "L" 51 - 70 5,000 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 --- 250 50 / 60 --- 0.02 - 100 --- 3,000 TC1, 2, OL0, U2 TC1, 2, OL0, U2 --- 3 0.02 - 70 --- 5,000 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 3 poles breaking 3 phase --- 0.02 - 90 --- 5,000 TC1, 2, OL0, U1 TC1, 2, OL0, U1 Must have Agency "L" 277 50 / 60 1 0.02 - 50 --- 5,000 -- TC1, 2, OL1, C1 TC1, 2, OL1, C1 --- 0.02 - 30 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 3 poles breaking 3 phase 480/277 50 / 60 3 5,000 -- --- TC1, 2, OL0, C1 TC1, 2, OL0, C1 --- 0.02 - 30 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 2 poles breaking 1 phase 480 50 / 60 1 5,000 -- --- TC1, 2, OL0, C1 TC1, 2, OL0, C1 --- 80 DC --- 0.02 - 50 --- --- 7,500 TC1, 2, OL1, U1 TC1, 2, OL1, U1 --- 125 50 / 60 1 0.02 - 50 --- --- 3,000 TC1, OL1, U2 TC1, OL1, U2 Per pole rating 3,500 TC1, OL1, U2 TC1, OL1, U2 2 or 3 poles breaking single phase 125/250 50 / 60 1 0.02 - 50 --- --- 3,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 2 or 3 poles breaking single phase Dual Coil 1 --- 3,500 TC1, OL1, U2 TC1, OL1, U2 --- 250 50 / 60 0.02 - 50 --- --- 3,000 TC1, OL0, U2 TC1, OL0, U2 Per pole rating 3 5,000 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 --- 277 50 / 60 1 0.02 - 50 --- 5,000 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 3 poles breaking 3 phase 80 DC --- 0.02 - 50 --- --- 7,500 TC1, 2, OL1, U1 TC1, 2, OL1, U1 --- 277 50 / 60 1 0.02 - 50 --- 5,000 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 --- 250 50 / 60 3 0.02 - 50 --- 5,000 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 3 poles breaking 3 phase Shunt 0.02 - 30 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 3 poles breaking 3 phase 480/277 50 / 60 3 5,000 --- --- 31 - 50 TC1, 2, OL0, C1 TC1, 2, OL0, C1 --- 0.02 - 30 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 2 poles breaking 1 phase 480 50 / 60 1 5,000 --- --- 31 - 50 TC1, 2, OL0, C1 TC1, 2, OL0, C1 --- 80 DC --- 0.02 - 50 --- --- 7,500 TC1, 2, OL1, U1 TC1, 2, OL1, U1 --- Relay 277 50 / 60 1 0.02 - 50 --- 5,000 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 --- 250 50 / 60 3 0.02 - 50 --- 5,000 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 3 poles breaking 3 phase 71 - 100 65 DC --- --- --- --- --- --- --- --- 71 - 100 80 DC --- --- --- --- --- --- --- --- 125 50 / 60 1 0.02 - 100 --- --- --- --- --- --- Switch Only 125/250 50 / 60 1 0.02 - 100 --- --- --- --- --- 2 or 3 poles breaking single phase 1 0.02 - 100 --- 250 50 / 60 --- --- --- --- --- 3 0.02 - 70 --- 277 50 / 60 1 0.02 - 50 --- --- --- --- --- --- 0.02 - 30 --- 3 poles breaking 3 phase 480/277 50 / 60 3 --- --- --- --- --- 31 - 50 --- Notes: 1. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 4 C-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller. Notes: C-SERIES TABLE B: Manual Motor Controllers 1. Requires branch circuit backup with a UL Listed Type K5 or RK5 fuse rated 15A Minimum and no Voltage Current Rating Horsepower Ratings Circuit more than 4 times full load amps not to exceed Configuration Max. Rating Frequency Phase Full Load Amps Max. HP 125A for 50 Amp or less rating and not to exceed 1 175A for 51 through 100A rating. 120 50 / 60 1 0.02 - 50 7 1/2 2. UL Recognized and CSA Certified at 480V refers Series, 1 0.02 - 20 3 to 3 and 4 pole versions used in a 3Ø, WYE 1 250 50 / 60 Shunt & connected circuit or a 2 pole version with 2 poles 3 0.02 - 20 5 breaking 1Ø and backed up with a series fusing as Relay Switch 1 277 50 / 60 1 0.02 - 20 3 stated in note 1. Only * Shunt and Relay Trip - Voltage Coil 2 480 50 / 60 3 0.02 - 20 5 Construction not current coils Table C: Lists UL Recognized, CSA Accepted, VDE and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. C-SERIES TABLE C: Component Supplementary Protectors Voltage Current Rating Short Circuit Capacity (Amps) UL / CSA VDE TUV Application Circuit Codes Full General (Inc) (Icn) (Inc) (Icn) Construction Notes Max. With Without Configuration Frequency Phase Load Purpose With Without With Without Rating Backup Backup 1 UL / CSA Amps Amps Backup Backup Backup Backup Fuse Fuse Fuse Fuse Fuse Fuse --- 0.10 - 70 --- --- 7,500 --- 5,000 5,000 1,500 TC1,2,OL1,U1 --- 80 DC Agency F, H, J or R --- 71 - 100 71 - 100 --- 10,000 --- 5,000 --- 5,000 TC1,2,OL0,U1 125 DC --- 1 - 50 --- --- 5,000 --- --- --- 5,000 TC1,2,OL1,U1 Agency J or R DC --- 0.10 - 50 --- --- --- 5,000 2P, Agency J or R Series 0.10 - 70 3,000 1,500 3,000 1,500 --- 250 1 --- --- 5,000 TC1,2,OL1,U1 50 / 60 0.10 - 100 --- --- Agency J or R 5,000 5,000 3 0.10 - 90 --- --- 3,000 1,500 Rocker 2 415 50 / 60 3 0.10 - 30 --- 5,000 --- 3,000 1,500 TC1,2,OL1,C1 5,000 2,500 Handle, Agency F, H, J or R 80 DC --- 7,500 --- 5,000 --- Dual Coil 0.10 - 30 --- --- 1,500 1,500 TC1,2,OL1,U1 250 50 / 60 1 & 3 5,000 3,000 3,000 80 DC --- 0.10 - 70 --- --- 7,500 --- 5,000 5,000 1,500 TC1,2,OL1,U1 --- 250 50 / 60 1 & 3 0.10 - 70 --- --- 5,000 3,000 1,500 3,000 1,500 TC1,2,OL1,U1 --- Shunt 3,000 1,500 Rocker 2 415 50 / 60 3 0.10 - 30 --- 5,000 --- 3,000 1,500 TC1,2,OL1,C1 5,000 2,500 Handle, Agency F, H, J or R Notes: 1. General Purpose ratings for UL/CSA only. 2. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating. Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case Circuit Breaker. C-SERIES TABLE D: UL489 Listed Branch Circuit Breakers Voltage Current Rating Interrupting Capacity (Amps) Circuit Construction Notes Configuration Max. Rating Frequency Phase Full Load Amps Without Backup Fuse 1 50,000 0.10 - 100 Limited to 2 Poles Max from 71 - 100 Amps 10,000 80 DC --- 2 Poles - Parallel Poles 101 - 150 10,000 3 Poles - Parallel Poles 151 - 250 10,000 1 - 3 Poles 125 DC --- 0.10 - 100 5,000 1 or 2 Poles (2 poles required for 250 Volts) 125 / 250 DC --- 0.10 - 50 5,000 Series 0.10 - 50 10,000 120 50 / 60 1 1 - 3 Poles 51 - 70 5,000 5,000 120 / 240 50 / 60 1 0.10 - 50 2 or 3 Poles (1 pole of a 3 pole unit is neutral) 1 10,000 1 Pole 0.10 - 30 5,000 240 50 / 60 1 0.10 - 20 10,000 2 Poles Notes: 277 50 / 60 1 0.10 - 20 10,000 1-2 Poles 1 Special catalog number required. --- Dual Coil 120 50 / 60 1 0.10 - 30 10,000 Consult factory. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - General Specifications | 5 Electrical Tables Table E: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. C-SERIES TABLE E: UL1500 (Marine Ignition Protection) Interrupting Voltage Current Rating Application Codes Capacity (Amps) Circuit Construction Configuration Notes Max. Full Load Without Frequency Phase UL CSA Rating Amps Backup Fuse 0.02 - 100 48 DC --- 5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 --- 101 - 150 65 DC --- 0.02 - 100 1,500 TC1, 2, OL0, U1 TC1, 2, OL0, U1 --- 80 DC --- 0.02 - 70 1,500 TC1, 2, OL1, U1 TC1, 2, OL1, U1 --- Series 0.02 - 70 5,000 125 50 / 60 1 TC1, 2, OL1, U1 TC1, 2, OL1, U1 --- 71 - 100 1,500 0.02 - 70 --- 250 50 / 60 1 1,500 TC1, 2, OL1, U1 TC1, 2, OL1, U1 2 Poles Breaking 71 - 100 Single Phase Table F: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. C-SERIES TABLE F: PARALLEL POLE CONSTRUCTION UL489A Listed for Communications Equipment Voltage Current Rating Interrupting Capacity (Amps) Circuit Configuration Max. Rating Frequency General Purpose Amps Without Backup Fuse Series 80 DC 100 - 250 10,000 Agency Certifications Component Supplementary UL Recognized CSA Accepted Component Recognition Program Protector under Class 3215 30, UL Standard 1077 as Protectors Supplementary FIle 047848 0 000 CSA (Guide CCN/QVNU2, File E75596) Standard C22.2 No. 235 Switches, Industrial Control Circuit Breaker Model Case UL Standard 508 CSA Certified (Guide CCN/NRNT2, File E148683) (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems TUV Certified EN60934, under License No. (Guide PEQZ2, File E75596) R72040875 Ignition Protection UL Listed UL Standard 489 Circuit Breakers, Molded Case, VDE Certified EN60934, VDE 0642 under File (Guide DIVQ, File E129899) No. 10537 UL Standard 489A Communications Equipment (Guide CCN/DITT, File E189195) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 6 C-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme C A 3 B 0 10 450 1 2 1 C 8 9 10 11 1 2 3 4 5 6 7 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting Agency Switch & Delay Color Bezel/Barrier Approval 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 030 0.030 245 0.450 440 4.000 616 16.000 2 ACTUATOR 035 0.035 250 0.500 445 4.500 617 17.000 A Handle, one per pole 040 0.040 255 0.550 450 5.000 618 18.000 B Handle, one per multipole unit 045 0.045 260 0.600 455 5.500 620 20.000 S Mid-Trip Handle, one per pole 050 0.050 265 0.650 460 6.000 622 22.000 T Mid-Trip Handle, one per pole & Alarm Switch 055 0.055 270 0.700 465 6.500 624 24.000 060 0.060 275 0.750 470 7.000 625 25.000 065 0.065 280 0.800 475 7.500 630 30.000 2 3 POLES 070 0.070 285 0.850 480 8.000 635 35.000 1 One 3 Three 5 Five 075 0.075 290 0.900 485 8.500 640 40.000 2 Two 4 Four 6 Six 080 0.080 295 0.950 490 9.000 650 50.000 9 085 0.085 410 1.000 495 9.500 660 60.000 9 090 0.090 512 1.250 610 10.000 670 70.000 3 4 4 CIRCUIT F Relay Trip (Current) 9 095 0.095 415 1.500 710 10.500 680 80.000 3 4 A Switch Only (No Coil) G Relay Trip (Voltage) 9 210 0.100 517 1.750 611 11.000 685 85.000 4,5 B Series Trip (Current) H Dual Coil with Shunt Trip 9 215 0.150 420 2.000 711 11.500 690 90.000 9 C Series Trip (Voltage) Voltage Coil 220 0.200 522 2.250 612 12.000 695 95.000 4 4,5 9 D Shunt Trip (Current) K Dual Coil with Relay Trip 225 0.250 425 2.500 712 12.500 810 100.00 4 E Shunt Trip (Voltage) Voltage Coil 230 0.300 527 2.750 613 13.000 7 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) CODE AMPERES A06 6 DC A32 32 DC J12 12 AC J65 65 AC 5 AUXILIARY / ALARM SWITCH A12 12 DC A48 48 DC J18 18 AC K20 120 AC 0 without Aux Switch A18 18 DC A65 65 DC J24 24 AC L40 240 AC 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug A24 24 DC J06 6 AC J48 48 AC 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. (Gold Contacts) 15 8 TERMINAL 10 12 1 Stud 10-32 6 Stud M6 11 13,15 2 Screw 10-32 7 0.250 Double Click Connect 6 FREQUENCY & DELAY 12 15 3 Stud 1/4-20 9 7/16” Clip Terminal 3 03 DC 50/60Hz, Switch Only 30 DC 50/60Hz Instantaneous 11 14 4 Stud M5 x 0.8 A Plug-In Stud 7 10 DC Instantaneous 31 DC 50/60Hz Ultra Short 11 11,15 5 Screw M5 x 0.8 C 5/16” Clip Terminal 11 DC Ultra Short 32 DC 50/60Hz Short 12 DC Short 34 DC 50/60Hz Medium 14 DC Medium 36 DC 50/60Hz Long 16 9 ACTUATOR COLOR & LEGEND 8 16 DC Long 42 50/60Hz Short, Hi-Inrush Actuator Color I-O ON-OFF Dual Legend Color 7 8 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush White A B 1 Black 8 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush Black C D 2 White 8 22 50/60Hz Short 52 DC Short, Hi-Inrush Red F G 3 White 8 24 50/60Hz Medium 54 DC Medium, Hi-Inrush Green H J 4 White 26 50/60Hz Long 56 DC Long, Hi-Inrush Blue K L 5 White Notes: Yellow M N 6 Black 1 Actuator Code: Gray P Q 7 Black A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. Orange R S 8 Black B: Handle location as viewed from front of breaker: 17 Black (short handle) T U 9 White 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available 10 MOUNTING / BARRIERS with circuit codes B, C, D, E, F, G, H and K. MOUNTING STYLE BARRIERS VOLTAGE T: Handle moves to mid-position and alarm switch activates only upon electrical trip Threaded Insert of the breaker. Available with circuit codes B & C. 2 Standard multipole units have all poles identical except when specifying auxiliary 1 6-32 x 0.195 inches no < 300 switch and/or mixed poles. 4 pole max with VDE. 5th pole available as Series Trip with A 6-32 X 0.195 inches yes < 300 18 Voltage Coil only. C 6-32 X 0.195 inches yes ≥ 300 3 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE 2 ISO M3 x 5mm no < 300 Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to B ISO M3 x 5mm yes < 300 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 18 D ISO M3 x 5mm yes ≥ 300 For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. Front panel Snap-In, 1.00” [25.4mm] wide bezel 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit 17 E with Handleguard no < 300 Codes D, F, H & K available up to 50 amps maximum Current Rating. 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously 11 AGENCY APPROVAL on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip C UL Recognized, CSA Accepted instantaneously and are rated for intermittent duty only. D VDE Certified, UL Recognized, CSA Accepted 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole E TUV Certified, UL Recognized, CSA Accepted breakers, one auxiliary switch is supplied, mounted in the extreme right pole. H UL489 Construction: VDE Certified, UL Recognized, CSA Accepted 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), 9 Current Ratings 60 - 70 are available up to four poles maximum. Ratings 71 - 100 CSA Accepted are available up to two poles maximum. L UL489 Construction: UL Recognized, CSA Accepted 10 Terminal Code 1 available to 60 amps maximum. R UL489 Construction: TUV Certified, UL Recognized, CSA Accepted 11 Terminal Codes 2, 4, 5 and C available to 50 amps maximum. 12 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 15 Terminal Codes 7, 9 & C are not VDE approved. 16 No marking available. Consult factory. VDE/TUV Approval requires dual (I-O, ON-OFF) or I-O markings on all handles. 17 Single pole only. 18 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Circuit Breaker - Handle UL489 & UL489A Listed / Parallel Pole – Ordering Scheme 7 C A 2 P 0 D4 820 3 2 1 M T 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting Max. App. Agency Switch & Delay Color Rating Approval 5 8 TERMINAL 1 SERIES 3 1/4-20 threaded Stud C 6 M6 threaded Stud 3 A Plug-In Stud 2 ACTUATOR A Handle, one per pole 2 1 9 ACTUATOR COLOR S Mid-Trip Handle, one per pole 1 T Mid-Trip, one per pole & Alarm Switch LEGEND ON-OFF Dual Legend Color White B 1 Black 4 3 POLES Black D 2 White 1 One Red G 3 White 2 Two Green J 4 White 3 Three Blue L 5 White Yellow N 6 Black Gray Q 7 Black 4 CIRCUIT Orange S 8 Black P Series Trip (parallel pole) 10 MOUNTING 5 AUXILIARY / ALARM SWITCH Threaded Insert 0 without Aux Switch 6 S.P.S.T., 0.139 Solder Lug 1 6-32 x 0.195 inches 2 S.P.D.T., 0.110 Q.C. Term. 7 S.P.S.T., 0.110 Q.C 2 ISO M3 x 5mm 3 S.P.D.T., 0.139 Solder Lug Term. (Gold Contacts) 4 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. (Gold Contacts) 9 S.P.D.T., 0.187 Q.C. Term. 11 MAXIMUM APPLICATION RATING 5 S.P.S.T., N.O., 0.110 Q.C M 80 DC Term. (Gold Contacts) 6 12 AGENCY APPROVAL 6 FREQUENCY & DELAY A Without Approval D1 DC Ultra Short G UL489 Listed D2 DC Short J UL489A Listed, TUV Certified D4 DC Medium K UL489A Listed, VDE Certified D6 DC Long T UL489A Listed 7 UL489A Listed, TUV Certified 4 7 CURRENT RATING (AMPERES) CODE AMPERES Notes: 810 100.00 813 130.00 817 170.00 820 200.00 1 Handle moves to Mid-Position only upon electrical trip of C/B when Actuator S is 811 110.00 814 140.00 917 175.00 922 225.00 specified. When Actuator Code T is specified, handle moves to Mid Position and 812 120.00 815 150.00 818 180.00 825 250.00 Alarm Switch actuates only upon electrical trip of C/B. Code T is only available with 912 125.00 816 160.00 819 190.00 Circuit Code N. 2 Standard Handle colors are White, Black, Red & Yellow. 3 Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line and Load Terminals. For Terminal Code A, Line and Load Terminals must be connected to a copper bus bar having a minimum cross-section of 0.078 square inches. Terminal Code A is not available on the single pole unit. 4 Ratings for 101 to 125 amps are available in 1-pole. Ratings from 110 to 200 amps are available in 2-pole. For ratings from 225-300 amps, specify 3-pole. 5 1 pole only available with terminal codes 3 and 6. 6 Agency codes K and 7 are not available with 1 pole. Agency code J is only available with 1 pole. Agency code G is only available in 2 and 3 pole. Circuit P, ratings 101-150 amps (2 pole) and ratings 151-250 amps (3 pole). Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 8 C-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme C A 3 B 0 14 450 1 2 1 K G 8 9 10 11 12 1 2 3 4 5 6 7 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. App. Agency Switch & Delay Color Barriers Rating Approval 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 210 0.100 295 0.950 470 7.000 618 18.000 215 0.150 410 1.000 475 7.500 620 20.000 1 2 ACTUATOR 220 0.200 512 1.250 480 8.000 622 22.000 A Handle, one per pole 225 0.250 415 1.500 485 8.500 624 24.000 B Handle, one per multipole unit 230 0.300 517 1.750 490 9.000 625 25.000 235 0.350 420 2.000 495 9.500 630 30.000 S Mid-Trip Handle, one per pole 240 0.400 522 2.250 610 10.000 635 35.000 T Mid-Trip Handle, one per pole & Alarm Switch 245 0.450 425 2.500 710 10.500 640 40.000 250 0.500 527 2.750 611 11.000 660 60.000 2 255 0.550 430 3.000 711 11.500 670 70.000 3 POLES 260 0.600 435 3.500 612 12.000 680 80.000 1 One 2 Two 3 Three 265 0.650 440 4.000 712 12.500 685 85.000 270 0.700 445 4.500 613 13.000 690 90.000 275 0.750 450 5.000 614 14.000 695 95.000 4 CIRCUIT 280 0.800 455 5.500 615 15.000 810 100.00 B Series Trip (Current) 285 0.850 460 6.000 616 16.000 290 0.900 465 6.500 617 17.000 3 5 AUXILIARY / ALARM SWITCH 0 without Aux Switch 6 8 TERMINAL 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 7 9 1 Stud 10-32 6 Stud M6 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. 8 9 2 Screw 10-32 9 7/16” Clip Terminal 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. 9 10 3 Stud 1/4-20 A Plug-In Stud (Gold Contacts) 8 8 4 Stud M5 x 0.8 C 5/16” Clip Terminal 8 5 Screw M5 x 0.8 6 FREQUENCY & DELAY 11 DC Ultra Short 26 50/60Hz Long 11 9 ACTUATOR COLOR & LEGEND 4 12 DC Short 42 50/60Hz Short, Hi-Inrush Actuator Color ON-OFF Dual Legend Color 4 14 DC Medium 44 50/60Hz Medium, Hi-Inrush White B 1 Black 4 16 DC Long 46 50/60Hz Long, Hi-Inrush Black D 2 White 4 21 50/60Hz Ultra Short 52 DC Short, Hi-Inrush Red G 3 White 4 22 50/60Hz Short 54 DC Medium, Hi-Inrush Green J 4 White 4 24 50/60Hz Medium 56 DC Long, Hi-Inrush Blue L 5 White Yellow N 6 Black Notes: Gray Q 7 Black 1 Actuator Code: Orange S 8 Black A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum. S: Handle moves to mid-position only upon electrical trip of the breaker. 10 MOUNTING / BARRIERS T: Handle moves to mid-position and alarm switch activates only upon electrical trip 12 MOUNTING STYLE BARRIERS of the breaker. Threaded Insert 2 Standard multipole units have all poles identical except when specifying auxiliary 1 6-32 x 0.195 inches yes switch and/or mixed poles. 2 ISO M3 x 5mm yes 2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating code C) applications, have all poles identical except when specifying auxiliary / alarm switch which is normally supplied in extreme right pole per figure B. Terminal 11 MAXIMUM APPLICATION RATING barriers are required on all multipole breakers. B 125 DC Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd 2 C 120/240 AC pole has the same construction as poles 1 & 2. 3 On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme D 240 AC right pole. K 120 AC VDE approval on auxiliary switch codes 2, 3 & 4 only. F 277 AC Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit, M 80 DC only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC, and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit breaker, is supplied from factory with common terminal of auxiliary / alarm switch 11 12 AGENCY APPROVAL connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated A without approvals 120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common F UL489 Listed, CSA Certified & VDE Certified terminal connected to breaker line terminal. Consult factory for special catalog G UL489 Listed & CSA Certified number. J UL489 Listed, CSA Certified & TUV Certified 4 Available up to 50 amps maximum. 5 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 6 Terminal Codes 9 & C are not VDE approved. 7 Terminal Code 1 available to 60 amps maximum. 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 9 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 10 Terminal Code A available to 100 amps maximum. 11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles. 12 Barriers supplied on multi-pole units only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme | 9 14 450 C C 3 B 0 1 2 1 D 6 7 8 9 10 11 1 2 3 4 5 Frequency Current Rating Terminal Actuator Mounting/ Agency Series Actuator Poles Circuit Aux/Alarm & Delay Switch Color Barriers Approval 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 2 ACTUATOR 030 0.030 245 0.450 440 4.000 616 16.000 Two Color Visi-Rocker 035 0.035 250 0.500 445 4.500 617 17.000 C Indicate ON, vertical legend 040 0.040 255 0.550 450 5.000 618 18.000 D Indicate ON, horizontal legend 045 0.045 260 0.600 455 5.500 620 20.000 E Indicate ON, no legend 050 0.050 265 0.650 460 6.000 622 22.000 F Indicate OFF, vertical legend 055 0.055 270 0.700 465 6.500 624 24.000 G Indicate OFF, horizontal legend 060 0.060 275 0.750 470 7.000 625 25.000 H Indicate OFF, no legend 065 0.065 280 0.800 475 7.500 630 30.000 Push-To-Reset, Visi-Rocker 070 0.070 285 0.850 480 8.000 635 35.000 N Indicate OFF, vertical legend 075 0.075 290 0.900 485 8.500 640 40.000 O Indicate OFF, horizontal legend 080 0.080 295 0.950 490 9.000 650 50.000 9 P Indicate OFF, no legend 085 0.085 410 1.000 495 9.500 660 60.000 9 Single color 090 0.090 512 1.250 610 10.000 670 70.000 9 J Vertical legend 095 0.095 415 1.500 710 10.500 680 80.000 9 K Horizontal legend 210 0.100 517 1.750 611 11.000 685 85.000 9 L No legend 215 0.150 420 2.000 711 11.500 690 90.000 9 Push-To-Reset, Single color 220 0.200 522 2.250 612 12.000 695 95.000 9 R Vertical legend 225 0.250 425 2.500 712 12.500 810 100.00 U Horizontal legend 230 0.300 527 2.750 613 13.000 7 V No legend OR VOLTAGE COIL (NORMAL RATED VOLTAGE) CODE AMPERES A06 6 DC A32 32 DC J12 12 AC J65 65 AC A12 12 DC A48 48 DC J18 18 AC K20 120 AC 2 3 POLES A18 18 DC A65 65 DC J24 24 AC L40 240 AC 1 One 2 Two 3 Three A24 24 DC J06 6 AC J48 48 AC 4 4 CIRCUIT F Relay Trip (Current) 3 4 8 TERMINAL A Switch Only (No Coil) G Relay Trip (Voltage) 10 12 4,5 1 Stud 10-32 6 Stud M6 B Series Trip (Current) H Dual Coil with Shunt Trip 11 13 2 Screw 10-32 7 0.250 Double Quick Connect C Series Trip (Voltage) Voltage Coil 12 4 4,5 3 Stud 1/4-20 9 7/16” Clip Terminal D Shunt Trip (Current) K Dual Coil with Relay Trip 11 14 4 4 Stud M5 x 0.8 A Plug-In Stud E Shunt Trip (Voltage) Voltage Coil 11 5 Screw M5 x 0.8 C 5/16” Clip Terminal 6 5 AUXILIARY / ALARM SWITCH 16,17,18 9 ACTUATOR COLOR & LEGEND 0 without Aux Switch Actuator or 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug Visi-Color Marking: Marking Color: 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. Single Color 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker (Gold Contacts) White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red 6 FREQUENCY & DELAY Green H J 4 White Green 03 DC 50/60Hz, Switch Only 30 DC 50/60Hz Instantaneous Blue K L 5 White Blue 7 10 DC Instantaneous 31 DC 50/60Hz Ultra Short Yellow M N 6 Black Yellow 11 DC Ultra Short 32 DC 50/60Hz Short Gray P Q 7 Black Gray 12 DC Short 34 DC 50/60Hz Medium Orange R S 8 Black Orange 14 DC Medium 36 DC 50/60Hz Long 8 16 DC Long 42 50/60Hz Short, Hi-Inrush 7 8 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 1 10 MOUNTING / BARRIERS 8 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush STANDARD ROCKER BEZEL BARRIERS VOLTAGE 8 22 50/60Hz Short 52 DC Short, Hi-Inrush 1 6-32 x 0.195 inches no <300 8 24 50/60Hz Medium 54 DC Medium, Hi-Inrush 2 6-32 x 0.195 inches yes <300 8 26 50/60Hz Long 56 DC Long, Hi-Inrush 19 3 6-32 x 0.195 inches yes ≥300 4 ISO M3 x 5mm no <300 Notes: 5 ISO M3 x 5mm yes <300 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 19 6 ISO M3 x 5mm yes ≥300 2 Multi-pole breakers have all poles identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from ROCKERGUARD BEZEL front panel: 2 pole – left pole; 3 pole – center pole. A 6-32 x 0.195 inches no <300 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE C 6-32 x 0.195 inches yes <300 Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 19 E 6-32 x 0.195 inches yes ≥300 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. G ISO M3 x 5mm no <300 For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit J ISO M3 x 5mm yes <300 19 Codes D,F,H & K available up to 50 amps maximum Current Rating. L ISO M3 x 5mm yes ≥300 5 Consult factory for available Dual Coil options, as special catalog number is PUSH-TO-RESET BEZEL required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously B 6-32 x 0.195 inches no <300 on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip D 6-32 x 0.195 inches yes <300 instantaneously and are rated for intermittent duty only. 19 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole F 6-32 x 0.195 inches yes ≥300 breakers, one auxiliary switch is supplied, mounted in the extreme right pole. Auxiliary H ISO M3 x 5mm no <300 switch codes 2, 3 & 4 are VDE approved. J ISO M3 x 5mm yes <300 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 19 M ISO M3 x 5mm yes ≥300 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. 9 Current Ratings 60-70 are available up to four poles maximum. Ratings 71-100 are available up to two poles maximum. 10 Terminal Code 1 available to 60 amps maximum. 11 AGENCY APPROVAL 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. C UL Recognized & CSA Accepted 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. D VDE Certified, UL Recognized & CSA Accepted 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. E TUV Certified, UL Recognized & CSA Accepted 15 Terminal Codes 7, 9 & C are not VDE approved. H UL489 Construction: VDE Certified, UL Recognized & CSA Accepted 16 Color shown is visi and legend with remainder of rocker black I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), 17 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered. & CSA Accepted Dual = ON-OFF/I-O legend with actuator codes C - G, and J, K, N, O, R, & U. None = no legend with actuator codes H, L, P, V. Rockerguard available with actuator L UL489 Construction: UL Recognized & CSA Accepted codes C - L. Push-to-reset available with actuator codes N, O, P, R, U, V. R UL489 Construction: TUV Certified, UL Recognized & CSA Accepted 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 10 C-Series Circuit Breaker - Rocker UL489A Listed / Parallel Pole – Ordering Scheme C 1 2 P 0 D4 820 3 2 A M T 1 2 3 4 5 6 7 8 9 10 11 12 Circuit Terminal Actuator Mounting Max. App. Agency Series Actuator Poles Aux/Alarm Frequency Current Rating Color Rating Approval Switch & Delay 3 8 TERMINAL 1 SERIES C 3 Stud 1/4-20 6 Stud M6 1 A Plug-In Stud 2 ACTUATOR C Curved Rocker, Two Color Visi, Indicate On, Vertical Legend D Curved Rocker, Two Color Visi, Indicate On, Horizontal Legend 9 ACTUATOR COLOR F Curved Rocker, Two Color Visi, Indicate Off, Vertical Legend LEGEND G Curved Rocker, Two Color Visi, Indicate Off, Horizontal Legend ON-OFF Dual Legend Color J Curved Rocker, Single Color, Vertical Legend White B 1 Black K Curved Rocker, Single Color, Horizontal Legend Black D 2 White N Curved Rocker, Push To Reset, Two Color Visi, Vertical Legend Red G 3 White O Curved Rocker, Push To Reset, Two Color Visi, Horizontal Legend Green J 4 White 1 Flat Rocker, Two Color Visi, Vertical Legend Blue L 5 White 2 Flat Rocker, Two Color Visi, Horizontal Legend Yellow N 6 Black 3 Flat Rocker, Single Color, Vertical Legend Gray Q 7 Black 4 Flat Rocker, Single Color, Horizontal Legend Orange S 8 Black 5 Flat Rocker, Push To Reset, Two Color Visi, Vertical Legend 6 Flat Rocker, Push To Reset, Two Color Visi, Horizontal Legend 10 MOUNTING 7 Flat Rocker, Push To Reset, Single Color, Vertical Legend ROCKER / MOUNTING INSERT STYLE 8 Flat Rocker, Push To Reset, Single Color, Horizontal Legend A Standard Rocker Bezel - 6-32 Inserts B Standard Rocker Bezel - M3 Inserts 2 3 POLES C Rocker Guard Bezel - 6-32 Inserts D Rocker Guard Bezel - M3 Inserts 1 One 2 Two 3 Three E Standard Bezel with recessed Off Side Flat Rocker - 6-32 Inserts F Standard Bezel with recessed Off Side Flat Rocker - M3 Inserts 4 CIRCUIT G Push to Reset Bezel - 6-32 Inserts P Series Trip (parallel pole) H Push to Reset Bezel - M3 Inserts 11 MAXIMUM APPLICATION RATING 5 AUXILIARY/ALARM SWITCH 0 without Aux Switch 6 S.P.S.T., 0.139 Solder Lug M 80 DC 2 S.P.D.T., 0.110 Q.C. Term. 7 S.P.S.T., 0.110 Q.C 3 S.P.D.T., 0.139 Solder Lug Term. (Gold Contacts) 4 4 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. 12 AGENCY APPROVAL (Gold Contacts) 9 S.P.D.T., 0.187 Q.C. Term. A Without Approval 5 S.P.S.T., N.O., 0.110 Q.C G UL489 Listed Term. (Gold Contacts) J UL489A Listed, TUV Certified T UL489A Listed 7 UL489A Listed, TUV Certified 6 FREQUENCY & DELAY Notes: D1 DC Ultra Short 1 Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line D2 DC Short and Load Terminals. For Terminal Code A, Line and Load Terminals must be D4 DC Medium connected to a copper bus bar having a minimum cross-section of 0.078 square D6 DC Long inches. Terminal Code A is not available on the single pole unit. 2 Ratings for 101 to 125 amps are available in 1-pole. Ratings from 110 to 200 amps are available in 2-pole. 2 7 CURRENT RATING (AMPERES) For ratings from 225-300 amps, specify 3-pole. CODE AMPERES 3 1 pole only available with terminal codes 3 and 6. 810 100.00 813 130.00 817 170.00 820 200.00 4 Agency codes K and 7 are not available with 1 pole. 811 110.00 814 140.00 917 175.00 922 225.00 Agency code J is only available with 1 pole. 812 120.00 815 150.00 818 180.00 825 250.00 Agency code G is only available in 2 and 3 pole. 912 125.00 816 160.00 819 190.00 Circuit P, ratings 101-150 amps (2 pole) and ratings 151-250 amps (3 pole). Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Rocker UL Listed – Ordering Scheme | 11 C C 3 B 0 14 450 1 2 A K G 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. App. Agency Switch & Delay Color Barriers Rating Approval 4 7 CURRENT RATING (AMPERES) 1 SERIES CODE AMPERES C 210 0.100 295 0.950 470 7.000 618 18.000 215 0.150 410 1.000 475 7.500 620 20.000 1 220 0.200 512 1.250 480 8.000 622 22.000 2 ACTUATOR 225 0.250 415 1.500 485 8.500 624 24.000 Two Color Visi-Rocker Single color 230 0.300 517 1.750 490 9.000 625 25.000 C Indicate ON, vertical legend J Vertical legend 235 0.350 420 2.000 495 9.500 630 30.000 D Indicate ON, horizontal legend K Horizontal legend 240 0.400 522 2.250 610 10.000 635 35.000 F Indicate OFF, vertical legend 245 0.450 425 2.500 710 10.500 640 40.000 G Indicate OFF, horizontal legend 250 0.500 527 2.750 611 11.000 650 50.000 255 0.550 430 3.000 711 11.500 660 60.000 ROCKER STYLE DESCRIPTIONS 260 0.600 435 3.500 612 12.000 670 70.000 INDICATE "ON" INDICATE "OFF" SINGLE COLOR 265 0.650 440 4.000 712 12.500 680 80.000 270 0.700 445 4.500 613 13.000 685 85.000 CODE "C" CODE "F" CODE "J" LINE 275 0.750 450 5.000 614 14.000 690 90.000 280 0.800 455 5.500 615 15.000 695 95.000 285 0.850 460 6.000 616 16.000 810 100.00 290 0.900 465 6.500 617 17.000 INDICATE COLOR LINE LINE LOCATION CODE "D" CODE "G" CODE "K" 8 TERMINAL 5 7 1 Stud 10-32 6 Stud M6 6 7,8 2 Screw 10-32 with saddle 9 7/16” Clip Terminal 7,8 & washer clamps A Plug-In Stud 7 6,8 LINE LINE LINE 3 Stud 1/4-20 C 5/16” Clip Terminal 6 4 Stud M5 x 0.8 6 5 Screw M5 x 0.8 with saddle & washer clamps 1 3 POLES 1 One 2 Two 3 Three 11 9 ACTUATOR COLOR & LEGEND Actuator or 4 CIRCUIT Visi-Color Marking: Marking Color: B Series Trip (current) Single Color 10 Color: ON-OFF Dual Rocker/Handle Visi-Rocker White B 1 Black White 2 5 AUXILIARY / ALARM SWITCH Black D 2 White n/a 0 without Aux Switch Red G 3 White Red 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug Green J 4 White Green 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. Blue L 5 White Blue 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. Yellow N 6 Black Yellow (Gold Contacts) Gray Q 7 Black Gray Orange S 8 Black Orange 6 FREQUENCY & DELAY 8 12 42 11 DC Ultra Short 50/60Hz Short, Hi-Inrush 10 MOUNTING / BARRIERS 8 13 12 DC Short 44 50/60Hz Medium, Hi-Inrush Standard Rocker Bezel BARRIERS 8 14 DC Medium 46 50/60Hz Long, Hi-Inrush Threaded Insert, 2 per pole 8 16 DC Long 52 DC Short, Hi-Inrush A 6-32 X 0.195 inches yes 8 21 50/60Hz Ultra Short 54 DC Medium, Hi-Inrush C ISO M3 x 5mm yes 22 50/60Hz Short 56 DC Long, Hi-Inrush Rockerguard Bezel 24 50/60Hz Medium Threaded Insert, 2 per pole 26 50/60Hz Long B 6-32 x 0.195 inches yes D ISO M3 x 5mm yes Notes: 1 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 11 MAXIMUM APPLICATION RATING 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right B 125 DC 14 pole. C 120/240 AC 3 Available up to 50 amps maximum. D 240 AC 4 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. F 277 AC 5 Terminal Code 1 available to 60 amps maximum. K 120 AC 6 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. M 80 DC 7 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. 8 Terminal Codes 9 & C are not VDE approved. 9 Color shown is visi and legend with remainder of rocker black 12 AGENCY APPROVAL 10 Dual = ON-OFF/I-O legend on actuator. A without approvals 11 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. 12 Rockerguard available with all actuator codes. F UL 489 Listed, CSA Certified, & VDE Certified 13 Barriers supplied on multi-pole units only. G UL 489 Listed & CSA Certified 14 2 & 3 pole circuit breakers required for 120/240 AC rating. J UL489 Listed, CSA Certified & TUV Certified Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com HORIZONTAL VERTICAL STYLE STYLE | 12 C-Series Circuit Breaker - Sealed Toggle UL Recognized – Ordering Scheme C M 3 B 0 10 450 1 0 1 C 8 9 10 11 1 2 3 4 5 6 7 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Legend Mounting Agency Switch & Delay Plate Bezel/Barrier Approval 9 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 030 0.030 245 0.450 440 4.000 616 16.000 2 ACTUATOR 035 0.035 250 0.500 445 4.500 617 17.000 M Sealed Toggle, one per pole 040 0.040 255 0.550 450 5.000 618 18.000 045 0.045 260 0.600 455 5.500 620 20.000 050 0.050 265 0.650 460 6.000 622 22.000 3 POLES 055 0.055 270 0.700 465 6.500 624 24.000 1 One 2 Two 3 Three 060 0.060 275 0.750 470 7.000 625 25.000 065 0.065 280 0.800 475 7.500 630 30.000 070 0.070 285 0.850 480 8.000 635 35.000 3 4 CIRCUIT F Relay Trip (current) 075 0.075 290 0.900 485 8.500 640 40.000 2 3 A Switch Only (no coil) G Relay Trip (voltage) 080 0.080 295 0.950 490 9.000 650 50.000 3,4 9 B Series Trip (current) H Dual Coil with Shunt Trip 085 0.085 410 1.000 495 9.500 660 60.000 9 C Series Trip (voltage) Voltage Coil 090 0.090 512 1.250 610 10.000 670 70.000 9 3 3,4 095 0.095 415 1.500 710 10.500 680 80.000 D Shunt Trip (current) K Dual Coil with Relay Trip 9 3 210 0.100 517 1.750 611 11.000 685 85.000 E Shunt Trip (voltage) Voltage Coil 9 215 0.150 420 2.000 711 11.500 690 90.000 9 220 0.200 522 2.250 612 12.000 695 95.000 9 225 0.250 425 2.500 712 12.500 810 100.00 5 AUXILIARY / ALARM SWITCH 230 0.300 527 2.750 613 13.000 0 without Aux Switch 7 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug CODE AMPERES 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. A06 6 DC A32 32 DC J12 12 AC J65 65 AC 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. A12 12 DC A48 48 DC J18 18 AC K20 120 AC (Gold Contacts) A18 18 DC A65 65 DC J24 24 AC L40 240 AC A24 24 DC J06 6 AC J48 48 AC 6 FREQUENCY & DELAY 2 8 TERMINAL 03 DC 50/60Hz, Switch Only 30 DC 50/60Hz Instantaneous 9 11 6 1 Stud 10-32 6 Stud M6 10 DC Instantaneous 31 DC 50/60Hz Ultra Short 10 12 2 Screw 10-32 7 0.250 Double Click Connect 11 DC Ultra Short 32 DC 50/60Hz Short 11 11 3 Stud 1/4-20 9 7/16” Clip Terminal 12 DC Short 34 DC 50/60Hz Medium 10 13 4 Stud M5 x 0.8 A Plug-In Stud 14 DC Medium 36 DC 50/60Hz Long 10 10 7 5 Screw M5 x 0.8 C 5/16” Clip Terminal 16 DC Long 42 50/60Hz Short, Hi-Inrush 6 7 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 7 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 7 9 LEGEND PLATE 22 50/60Hz Short 52 DC Short, Hi-Inrush 7 0 No Legend 24 50/60Hz Medium 54 DC Medium, Hi-Inrush 26 50/60Hz Long 56 DC Long, Hi-Inrush 10 MOUNTING / BARRIERS Notes: 1 Actuator Code M: Handle location as viewed from front of breaker: MOUNTING STYLE BARRIERS 2 pole - right pole 3 pole - center pole 1 Standard Hex Nut no 2 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE. A Standard Hex Nut (multi-pole units only) yes For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 11 AGENCY APPROVAL 3 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. C UL Recognized & CSA Accepted 4 Consult factory for available Dual Coil options, as special catalog number is I UL Recognized & CSA Accepted, UL1500 ignition protection required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously L UL Recognized & CSA Accepted with listed construction on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 5 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 7 Available with Circuit Codes B & D only, and up to 50 amps maximum. 8 Consult factory for current ratings 71-100, in three pole units, available as special catalog number only. 9 Terminal Code 1 available to 60 amps maximum. 10 Terminal Codes 2, 4, 5 and C available to 50 amps maximum. 11 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 12 Terminal Code 7 available to 25 amps maximum. 13 Terminal Code A available to 100 amps maximum. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Flat Rocker UL Recognized – Ordering Scheme | 13 C 1 2 B 0 10 450 1 2 1 E 8 9 10 11 1 2 3 4 5 6 7 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Agency Switch & Delay Color Barriers Approval 9 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 030 0.030 245 0.450 440 4.000 616 16.000 2 ACTUATOR 035 0.035 250 0.500 445 4.500 617 17.000 Two Color Visi-Rocker 040 0.040 255 0.550 450 5.000 618 18.000 1 Indicate OFF, 045 0.045 260 0.600 455 5.500 620 20.000 vertical legend 050 0.050 265 0.650 460 6.000 622 22.000 2 Indicate OFF, 055 0.055 270 0.700 465 6.500 624 24.000 horizontal legend 060 0.060 275 0.750 470 7.000 625 25.000 Single color 065 0.065 280 0.800 475 7.500 630 30.000 3 Vertical legend 070 0.070 285 0.850 480 8.000 635 35.000 4 Horizontal legend 075 0.075 290 0.900 485 8.500 640 40.000 Push-To-Reset, Visi-Rocker 080 0.080 295 0.950 490 9.000 650 50.000 5 Indicate OFF, 9 085 0.085 410 1.000 495 9.500 660 60.000 vertical legend 9 090 0.090 512 1.250 610 10.000 670 70.000 6 Indicate OFF, 9 095 0.095 415 1.500 710 10.500 680 80.000 horizontal legend 9 210 0.100 517 1.750 611 11.000 685 85.000 Push-To-Reset , Single color 9 215 0.150 420 2.000 711 11.500 690 90.000 7 Vertical legend 9 220 0.200 522 2.250 612 12.000 695 95.000 8 Horizontal legend 9 225 0.250 425 2.500 712 12.500 810 100.00 230 0.300 527 2.750 613 13.000 7 OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 2 3 POLES CODE AMPERES 1 One 2 Two 3 Three A06 6 DC A32 32 DC J12 12 AC J65 65 AC A12 12 DC A48 48 DC J18 18 AC K20 120 AC A18 18 DC A65 65 DC J24 24 AC L40 240 AC 4 4 CIRCUIT F Relay Trip (Current) A24 24 DC J06 6 AC J48 48 AC 3 4 A Switch Only (No Coil) G Relay Trip (Voltage) 4,5 B Series Trip (Current) H Dual Coil with Shunt Trip C Series Trip (Voltage) Voltage Coil 8 TERMINAL 4 4,5 D Shunt Trip (Current) K Dual Coil with Relay Trip 10 12 1 Stud 10-32 6 Stud M6 4 E Shunt Trip (Voltage) Voltage Coil 11 13 2 Screw 10-32 7 0.250 Double Quick Connect 12 15 3 Stud 1/4-20 9 7/16” Clip Terminal 11 14 4 Stud M5 x 0.8 A Plug-In Stud 6 5 AUXILIARY / ALARM SWITCH 11 15 5 Screw M5 x 0.8 C 5/16” Clip Terminal 0 without Aux Switch 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 16,17,18 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. 9 ACTUATOR COLOR & LEGEND 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. Actuator or Visi-Color Marking: Marking Color: (Gold Contacts) Single Color Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker White A B 1 Black White 6 FREQUENCY & DELAY Black C D 2 White n/a 03 DC 50/60Hz, Switch Only 30 DC 50/60Hz Instantaneous 7 Red F G 3 White Red 10 DC Instantaneous 31 DC 50/60Hz Ultra Short Green H J 4 White Green 11 DC Ultra Short 32 DC 50/60Hz Short Blue K L 5 White Blue 12 DC Short 34 DC 50/60Hz Medium Yellow M N 6 Black Yellow 14 DC Medium 36 DC 50/60Hz Long 8 Gray P Q 7 Black Gray 16 DC Long 42 50/60Hz Short, Hi-Inrush 7 8 Orange R S 8 Black Orange 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 8 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 8 22 50/60Hz Short 52 DC Short, Hi-Inrush 1 8 10 MOUNTING / BARRIERS 24 50/60Hz Medium 54 DC Medium, Hi-Inrush 8 STANDARD ROCKER BEZEL BARRIERS VOLTAGE 26 50/60Hz Long 56 DC Long, Hi-Inrush 1 6-32 x 0.195 inches no <300 2 6-32 x 0.195 inches yes <300 Notes: 19 1 Push-to-reset actuators have OFF portion of rocker shrouded. 3 6-32 x 0.195 inches yes ≥300 2 Multi-pole breakers have all poles identical except when specifying Auxiliary switch 4 ISO M3 x 5mm no <300 and/or mixed poles, and have one rocker per breaker. Rocker location as viewed 5 ISO M3 x 5mm yes <300 from front panel: 2 pole – left pole; 3 pole – center pole. 19 6 ISO M3 x 5mm yes ≥300 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE RECESSED OFF ROCKER Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 7 6-32 x 0.195 inches no <300 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. 8 6-32 x 0.195 inches yes <300 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit 9 6-32 x 0.195 inches yes ≥300 Codes D,F,H & K available up to 50 amps maximum Current Rating. A ISO M3 x 5mm no <300 5 Consult factory for available Dual Coil options, as special catalog number is required. C ISO M3 x 5mm yes <300 Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously E ISO M3 x 5mm yes ≥300 and are rated for intermittent duty only. PUSH-TO-RESET BEZEL 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole B 6-32 x 0.195 inches no <300 breakers, one auxiliary switch is supplied, mounted in the extreme right pole. Auxilary D 6-32 x 0.195 inches yes <300 switch codes 2, 3 & 4 are VDE approved. 19 F 6-32 x 0.195 inches yes ≥300 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. H ISO M3 x 5mm no <300 9 Current ratings 60-70 are available up to four poles maximum. Current ratings 71 - J ISO M3 x 5mm yes <300 100 are available up to two poles maximum. 19 M ISO M3 x 5mm yes ≥300 10 Terminal Code 1 available to 60 amps maximum. 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 11 AGENCY APPROVAL 14 Terminal Code A available to 100 amps maximum. C UL Recognized & CSA Accepted 15 Terminal Codes 7, 9 & C are not VDE approved. E TUV Certified, UL Recognized & CSA Accepted 16 Color shown is visi & legend with remainder of rocker black. Dual = ON-OFF/I-O legend. I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), 17 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-to-reset bezel/shroud matches visi-color of rocker with actuator & CSA Accepted codes 5 & 6. L UL489 Construction: UL Recognized & CSA Accepted 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. R UL489 Construction: TUV Certified, UL Recognized & CSA Accepted 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 & 3 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. 20 Recessed “OFF SIDE” available with actuator codes 1,2,3&4. Legends on rocker are available in ink stamping only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 14 C-Series Circuit Breaker - Flat Rocker UL489 Listed – Ordering Scheme C 1 2 B 0 14 450 1 2 A K G 8 9 10 11 12 1 2 3 4 5 6 7 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. App. Agency Switch & Delay Color Barriers Rating Approval 5 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 210 0.100 295 0.950 470 7.000 618 18.000 215 0.150 410 1.000 475 7.500 620 20.000 1 220 0.200 512 1.250 480 8.000 622 22.000 2 ACTUATOR 225 0.250 415 1.500 485 8.500 624 24.000 Two Color Visi-Rocker Push-To-Reset, Visi-Rocker 230 0.300 517 1.750 490 9.000 625 25.000 1 Indicate OFF, vertical legend 5 Indicate OFF, vertical legend 235 0.350 420 2.000 495 9.500 630 30.000 2 Indicate OFF, horizontal legend 6 Indicate OFF, horizontal legend 240 0.400 522 2.250 610 10.000 635 35.000 Single color Push-To-Reset , Single color 245 0.450 425 2.500 710 10.500 640 40.000 3 Vertical legend 7 Vertical legend 250 0.500 527 2.750 611 11.000 650 50.000 4 Horizontal legend 8 Horizontal legend 255 0.550 430 3.000 711 11.500 660 60.000 260 0.600 435 3.500 612 12.000 670 70.000 265 0.650 440 4.000 712 12.500 680 80.000 270 0.700 445 4.500 613 13.000 685 85.000 275 0.750 450 5.000 614 14.000 690 90.000 280 0.800 455 5.500 615 15.000 695 95.000 285 0.850 460 6.000 616 16.000 810 100.00 290 0.900 465 6.500 617 17.000 8 TERMINAL 6 8 1 Stud 10-32 6 Stud M6 7 8,9 2 Screw 10-32 9 7/16” Clip Terminal 8 8 3 Stud 1/4-20 A Plug-In Stud 7 7,9 4 Stud M5 x 0.8 C 5/16” Clip Terminal 7 5 Screw M5 x 0.8 10 9 ACTUATOR COLOR & LEGEND 2 3 POLES Actuator or 1 One 2 Two 3 Three Visi-Color Marking: Marking Color: Single Color 11,12 Color: ON-OFF Dual Rocker/Handle Visi-Rocker 4 CIRCUIT White B 1 Black White B Series Trip (current) Black D 2 White n/a Red G 3 White Red Green J 4 White Green 3 5 AUXILIARY / ALARM SWITCH Blue L 5 White Blue Yellow N 6 Black Yellow 0 without Aux Switch Gray Q 7 Black Gray 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug Orange S 8 Black Orange 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. (Gold Contacts) 10 MOUNTING / BARRIERS 15 STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole 6 FREQUENCY & DELAY 4 A 6-32 X 0.195 inches yes 11 DC Ultra Short 42 50/60Hz Short, Hi-Inrush 4 C ISO M3 x 5mm yes 12 DC Short 44 50/60Hz Medium, Hi-Inrush 14 4 RECESSED OFF ROCKER 14 DC Medium 46 50/60Hz Long, Hi-Inrush 4 Threaded Insert, 2 per pole 16 DC Long 52 DC Short, Hi-Inrush 4 E 6-32 x 0.195 inches yes 21 50/60Hz Ultra Short 54 DC Medium, Hi-Inrush 4 F ISO M3 x 5mm yes 22 50/60Hz Short 56 DC Long, Hi-Inrush 13 PUSH-TO-RESET BEZEL 24 50/60Hz Medium Threaded Insert, 2 per pole 26 50/60Hz Long B 6-32 x 0.195 inches yes D ISO M3 x 5mm yes Notes: 1 Push-to-reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed poles, and have one rocker per breaker. 11 MAXIMUM APPLICATION RATING 3 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme B 125 DC right pole. 16 C 120/240 AC 4 Available up to 50 amps maximum. D 240 AC 5 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. F 277 AC 6 Terminal Code 1 available to 60 amps maximum. K 120 AC 7 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. M 80 DC 8 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. 9 Terminal Codes 9 & C are not VDE approved. 10 Color shown is visi and legend with remainder of rocker black 12 11 Dual = ON-OFF/I-O legend on actuator. 12 AGENCY APPROVAL 12 TUV approval requires Dual (I-O, ON-OFF) markings on rocker. A without approvals 13 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered. G UL 489 Listed & CSA Certified Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator J UL489 Listed, CSA Certified & TUV Certified codes 5 & 6. 14 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker are available in ink stamping only. 15 Barriers supplied on multi-pole units only. 16 2 & 3 pole circuit breakers required for 120/240 AC rating. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams | 15 Circuit & Terminal Diagrams: in. [mm] .960 [24.38] .311 DIA [Ø7.90] .558 [14.17] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Available on Series Trip and Switch Only Circuits when called for on multi-pole units. Only one auxiliary switch is normally supplied, as viewed in mulit-pole identification scheme. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 16 C-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuits. 4 Available only as special catalog number. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Handle – Dimensional Specifications | 17 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 18 C-Series Circuit Breaker - Handleguard – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Arc Chute Barrier UL Recognized/Listed – Dimensional Specifications | 19 Dimensional Specifications: in. [mm] Notes: 1 Only 1-pole and 3-pole configurations shown. Arc chute (without barrier) and arc chute barrier also available for 2-pole construction. 2 Dimensions apply to all variations shown. 3 Notice that line and load terminal orientation for indicate on and indicate off rocker circuit breakers are opposite. 4 Screw type terminals shown for Rocker style (CF1, C11, etc) circuit breakers. For other terminal configurations see circuit and terminal diagrams. 5 All dimensions are in inches [millimeters]. 6 Tolerance ± .020 unless otherwise specified. 7 Must be ordered under a special catalog number. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 20 C-Series Circuit Breaker - Parallel Pole – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Sealed Toggle – Dimensional Specifications | 21 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 22 C-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com C-Series Circuit Breaker - Rocker – Dimensional Specifications | 23 Dimensional Specifications: in. [mm] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 24 C-Series Circuit Breaker - Flat Rocker – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 For pole orientation with horizontal legend, rotate front view clockwise 90°. 2 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Sales Representatives, Distributors & Company Profile | 25 Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. CANADA EUROPE USA MIDDLE EAST MEXICO AFRICA ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 @ Email: sales carlingtech.com @ Northern Region Sales Office: nrsm carlingtech.com @ Southeast Region Sales Office: sersm carlingtech.com @ Midwest Region Sales Office: mrsm carlingtech.com @ West Region Sales Office: wrsm carlingtech.com @ Latin America Sales Office: larsm carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Suite 1607, 16/F Tower 2, The Gateway, Harbour City, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 @ Email: sales carlingtech.com.hk @ Shenzhen, China: shenzhen carlingtech.com @ Shanghai, China: shanghai carlingtech.com @ Pune, India: india carlingtech.com @ Kaohsiung, Taiwan: taiwan carlingtech.com @ Yokohama, Japan: japan carlingtech.com | | Europe Middle East Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 @ Email: ltd.sales carlingtech.com @ Germany: gmbh carlingtech.com @ France: sas carlingtech.com www.carlingtech.com REV_02_2018

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the CA3X023363121D?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker Hydraulic Magnetic 1Pole 30A 277VAC/80VDC AA1-A0-03-630-1C1-C

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...