Electronics Finder Manufacturers C CARLING TECHNOLOGIES CB2-B2-24-660-321-E
About product Specifications Datasheet FAQ

CARLING TECHNOLOGIES CB2-B2-24-660-321-E

Image of CARLING TECHNOLOGIES CB2-B2-24-660-321-E

Description

Circuit Breaker Hydraulic Magnetic 2Pole 60A 250VAC
C-Series: 1-6 poles, 0.02-100amps, up to 480VWYE or up to 125VDC. Max interrupting capacity of 10,000A. Front panel mounting. Available with a choice of time delays & terminals with handle, rocker & metal toggle actuators. See datasheet.

Part Number

CB2-B2-24-660-321-E

Price

Request Quote

Manufacturer

CARLING TECHNOLOGIES

Lead Time

Request Quote

Category

Circuit Protection »  Circuit Breaker

Specifications

Manufacturer

Carling Technologies

Manufacturers Part #

CB2-B2-24-660-321-E

Industry Aliases

CB2-B2-24-660-321-E

Sub-Category

Circuit Breakers

Factory Pack Quantity

1

Datasheet

pdf file

C-Series_Details_%26_COS_040314.pdf

4209 KiB

Extracted Text

C-S C-Series eries CIRCUIT BREAKER The C-Series hydraulic-magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal options, actuator styles and colors. The C-Series employs a unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps. New thermoset glass filled polyester half shell construction provides for increased mechanical and electrical strength. The wiping contacts, mechanical linkage with two step actuaction, clean contacts providing high, positive contact pressure and longer contact life. Available with American Standard or Metric Threaded Stud terminals , or Saddle Clamp screw terminals. The optional mid-trip handle style actuator allows a visual indication of electrical overload with or without alarm feature. Eco-Friendly Resources: Download 3D CAD Files IGS STP Product Highlights: Typical Applications: Š Extensive list of Agency Approvals Š Marine Š Available with Standard or Metric Stud terminals, Š Telecom/Datacom or Saddle Clamp screw terminals Š Military Š Optional mid-trip handle style actuator Š Renewable Energy Š Unique arc chute design which allows for higher Š Generators & Welders interrupting capacities of up to 10,000 amps Š Exclusive Rockerguard and Push-To-Reset bezel Š Available with new solid color and two-color Visi- rocker® actuators Š New thermoset glass filled polyester half shell construction Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com www.carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 | 2 C-Series – General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector C-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS SHORT CIRCUIT CAPACITY (AMPS) VOLTAGE CURRENT RATING APPLICATION CODES UL/CSA CIRCUIT NOTES CONFIGURATION WITH BACKUP MAX. FULL LOAD GENERAL WITHOUT BACKUP FREQUENCY PHASE UL CSA 1 RATING AMPS PURPOSE AMPS FUSE FUSE 32 DC --- 0.02 - 100 --- --- 5000 TC1, OL1, U2 TC1, OL1, U2 48 DC --- 110 - 150 --- --- 5000 TC1, OL1, U2 TC1, OL1, U2 65 DC --- 0.02 - 70 --- --- 5000 TC1,2, OL1,U1 TC1,2, OL1,U1 --- 71 -100 --- 5000 TC1,2, OL0,U1 TC1,2, OL0,U1 0.02 - 70 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1 80 DC --- --- 71 -100 --- 7500 TC1,2, OL0,U1 TC1,2, OL0,U1 0.02 - 70 --- --- 10,000 TC1,2, OL1,U1 TC1,2, OL1,U1 Must Have Agency Code "L" 80 DC --- --- 71 -100 --- 10,000 TC1,2, OL0,U1 TC1,2, OL0,U1 Must Have Agency Code "L" 125 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" 125 / 250 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" 250 DC --- 0.02 - 50 --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L". 2 Pole Break Required for 250 Volts 0.02 - 100 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating 125 50 / 60 1 0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" 150 DC --- --- 80 - 100 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L" 150 DC --- --- 101 - 175 --- 5000 TC1, OL0, U3 --- Must Have Agency Code "L" Parallel Pole SERIES 0.02 - 100 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase 125 / 250 50 / 60 1 51 - 100 --- --- 1000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase 0.02 - 100 --- --- 5000 TC1,2,OL1,U2 TC1,2,OL1,U2 2 or 3 poles breaking single phase, "L" Agency Code 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating 1 0.02 - 100 --- --- 5000 TC1,2,OL1,U1 TC1,2,OL1,U1 Must Have Agency Code "L" 51 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 250 50 / 60 --- 0.02 - 100 --- 3000 TC1, OL0, U2 TC1, OL0, U2 3 0.02 - 70 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase --- 0.02 - 90 --- 5000 TC1,2,OL0,U1 TC1,2,OL0,U1 Must Have Agency Code "L" 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase 480 / 277 50 / 60 3 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 2 poles breaking 1 phase 480 50 / 60 1 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1 125 50 / 60 1 0.02 - 50 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Per Pole Rating 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 2 or 3 poles breaking single phase 125 / 250 50 / 60 1 0.02 - 50 --- --- 3000 TC1,2,OL1,U1 TC1,2,OL1,U1 2 or 3 poles breaking single phase DUAL COIL 1 0.02 - 50 --- --- 3500 TC1, OL1, U2 TC1, OL1, U2 250 50 / 60 0.02 - 50 --- --- 3000 TC1, OL0, U2 TC1, OL0, U2 Per Pole Rating 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase 80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase SHUNT 480 / 277 50 / 60 3 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 0.02 - 30 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 2 poles breaking 1 phase 480 50 / 60 1 --- 31 - 50 5000 --- TC1,2,OL0,C1 TC1,2,OL0,C1 80 DC --- 0.02 - 50 --- --- 7500 TC1,2, OL1,U1 TC1,2, OL1,U1 RELAY 277 50 / 60 1 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 250 50 / 60 3 0.02 - 50 --- 5000 --- TC1,2,OL1,C1 TC1,2,OL1,C1 3 poles breaking 3 phase 0.02 - 70 --- --- --- --- --- 65 DC --- --- 71 -100 --- --- --- --- 0.02 - 70 --- --- --- --- --- 80 DC --- --- 71 -100 --- --- --- --- 125 50 / 60 1 0.02 - 100 --- --- --- --- --- SWITCH ONLY 125 / 250 50 / 60 1 0.02 - 100 --- --- --- --- --- 2 or 3 poles breaking single phase 1 0.02 - 100 --- --- --- --- --- 250 50 / 60 3 0.02 - 70 --- --- --- --- --- 277 50 / 60 1 0.02 - 50 --- --- --- --- --- 0.02 - 30 --- --- --- --- --- 3 poles breaking 3 phase 480 / 277 50 / 60 3 --- 31 - 50 --- --- --- --- Notes for Table A: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating *Manufacturer reserves the right to change product specification without prior notice. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series – General Specifications 3 Electrical Tables Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller. RELAY Notes for Table B: 1 UL recognized and CSA Accepted at 480V refers to 3 & 4 pole versions used in a 3Ø, wye connected circuit or 2-pole version connected with 2 poles breaking. 1Ø and backed up with series fusing as stated above in note 1. *Series, Shunt and Relay Trip - Voltage Coil Construction not current coils Table C: Lists UL Recognized, CSA Accepted , VDE and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. Notes for Table C: 1 General Purpose ratings for UL/CSA only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 4 C-Series – General Specifications Electrical Tables Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case Circuit Breaker. C SERIES TABLE D : UL489 LISTED BRANCH CIRCUIT BREAKERS INTERRUPTING CURRENT VOLTAGE CAPACITY RATING CIRCUIT (AMPS) CONSTRUCTION NOTES CONFIGURATION MAX. FULL LOAD WITHOUT FREQUENCY PHASE RATING AMPS BACKUP FUSE 1 Limited to 2 Poles Max from 71 - 100 Amps. 50,000 80 DC --- 0.10 - 100 10,000 Limited to 2 Poles Max from 71 - 100 Amps. 125 DC --- 0.10 - 100 5,000 1 - 3 Poles 125 / 250 DC --- 0.10 - 50 5,000 1 or 2 Poles (2 Poles Required for 250 Volts) 0.10 - 50 10,000 1 - 3 Poles 120 50 / 60 1 SERIES 51 - 70 5,000 1 - 3 Poles 0.10 - 50 5,000 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 120 / 240 50 / 60 1 1 10000 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 0.10 - 50 240 50 / 60 1 0.10 - 30 5,000 1Pole 240 50 / 60 1 0.10 - 20 5,000 2 Pole 277 50 / 60 1 0.10 - 20 10,000 1Pole DUAL COIL 120 50 / 60 1 0.10 - 30 10,000 --- Notes from Table D: 1 Special catalog number required. Consult factory. Table E: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Table F: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series – General Specifications 5 Electrical Mechanical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz Endurance 10,000 ON-OFF operations @ 6 per (see Table A.) minute; with rated current & UL489: AC,240 VAC. (See Table D), voltage. 50/60 Hz, 125 VDC Trip Free All C-Series circuit breakers will trip Current Rating Standard current coils: 0.100, on overload, even when actuator is 0.250, 0.500, 0.750, 1.00, 2.50, forcibly held in the ON position. 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, Trip Indication The operating actuator moves 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, positively to the OFF position when 90.0 and 100 amps. Other ratings an overload causes the breaker to available, see Ordering Scheme. trip. With mid-trip, handle moves to Standard Voltage Coils DC - 6V, 12V; AC - 120V; other the mid position on electrical trip of ratings available, see Ordering the circuit breaker. With mid trip Scheme. handle with alarm switch, handle Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux. moves to the mid position and the Switch 1.0A, 65 VDC. 0.5A, alarm switch actuates when the 80VDC,1/4 HP, 125VAC,VDE & TUV circuit breaker is electrically 1.0 125 VAC. tripped. Insulation Resistance Minimum of 100 Megohms at 500 Physical VDC. Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one Number of Poles 1-6 poles ≤ 50A; 1-4 poles @ 51- minute between all electrically 70A; 1-2 poles 71-100A. UL489 isolated terminals. C-Series Circuit Handle: 1 pole ≤ 100A, 2 pole ≤ Breakers comply with the 8mm 50A; Rocker: 1 pole ≤ 100A. spacing and 3750V 50/60 Hz Internal Circuit Config. Series (with or without auxiliary dielectric requirements from switch, mid trip & mid trip with hazardous voltage to operator alarm switch) Shunt & Relay with accessible surfaces, between current or voltage trip coils, Dual adjacent poles and from main Coil, Switch Only (with or without circuits to auxiliary circuits per aux. switch). UL489: Series (with or Publications EN 60950 and without auxiliary switch, mid-trip & VDE 0805. midtrip with alarm switch). Resistance, Impedance Values from Line to Load Terminal - Weight Approx.112 grams/pole ( 3.95 oz). based on Series Trip Circuit Standard Colors Housing: Black RESISTANCE, IMPEDANCE VALUES Breaker. from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Environmental 1000 CURRENT TOLERANCE Designed and tested in accordance with requirements of (AMPS) (%) 100 specification MIL-PRF-55629 & MIL-STD-202 as follows: 0.10 - 5.0 15% Shock Withstands 100 Gs, 6ms sawtooth 10 5.1 - 20.0 25% while carrying rated current per O 20.1 - 100.0 35% Method 213, Test Condition “I”. H 1 M Instantaneous and ultrashort curves S 60 Hz 1/2 Cycle Inrush Pulse Tolerance 0.1 tested @ 90% of rated current. I r Time Delay Curves 42, 44 & 46 Vibration Withstands 0.060” excursion from (50 Amps Max.) 25x 0.01 10-55 Hz & 10 Gs 55-500 Hz, @ Time Delay Curves 22, 24 (100 Amps Max.) 12x 26 (70 Amps Max.) rated current per Method 204C, 0.001 0.01 0.1 1 10 100 t Test Cond. A. Instantaneous & AMPERE RATING 8.33 16.67 4.165 ultrashort curves tested @ 90% of CURRENT TOLERANCE (AMPS) (%) Pulse Tolerance Curves rated current. 0.100 - 5.0 15% 5.1 - 20.0 25% 60 Hz 1/2 Cycle 50 Hz 1/2 Cycle Moisture Resistance Method 106D, i.e., ten 24-hour 20.1 - 100 35% Inrush Pulse Tolerance Inrush Pulse Tolerance I I r r FIGURE 1 Time Delay Curves Time Delay Curves cycles @ +25°C to +65°C, 42, 44 & 46 22x 42, 44 & 46 (50 Amps Max.) 25x (50 Amps Max.) 80-98% RH. Time Delay Curves Time Delay Curves 10x 22, 24 (100 Amps Max.) 22, 24 (100 Amps Max.) 12x 26 (70 Amps Max.) 26 (70 Amps Max.) Salt Spray Method 101, Condition A (90-95% t t 10.0 20.0 RH @ 5% NaCl Solution, 96 hrs). 5.0 8.33 4.165 16.67 Time in Milliseconds Thermal Shock Method 107D, Condition A (five cycles @ -55°C to +25°C to +85°C 50 Hz 1/2 Cycle I Inrush Pulse Tolerance r to +25°C). Time Delay Curves 22x 42, 44 & 46 (50 Amps Max.) Operating Temperature -40°C to +85°C Time Delay Curves 10x 22, 24 (100 Amps Max.) 26 (70 Amps Max.) t 10.0 20.0 5.0 Time in Milliseconds Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Multiple of Multiple of Rated Current Rated Current Multiple of Multiple of Rated Current Rated Current | 6 C-Series - Agency Certifications Agency Certifications: UL Recognized UL Standard 1077 Component Recognition Program as Protectors, Supplementary (Guide CCN/QVNU2, File E75596) UL Standard 508 Motor Controllers, Manual (Guide CCN/NLRV2, File E135367) UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection UL Listed UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 489A Communications Equipment (Guide CCN/DITT, File E189195) CSA Accepted Component Supplementary Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235 CSA Certified Circuit Breaker Model Case (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M TUV Certified EN60934, under License No. R72041016 VDE Certified EN60934, VDE 0642 under File No. 10537 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Handle UL Recognized – Ordering Scheme 7 C A 3 B 0 10 450 1 2 1 C 1 2 3 4 5 6 7 8 9 10 11 Terminal Actuator Mounting Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Bezel/Barrier Approval Switch & Delay 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 2 ACTUATOR 030 0.030 245 0.450 440 4.000 616 16.000 A Handle, one per pole 035 0.035 250 0.500 445 4.500 617 17.000 B Handle, one per multipole unit 040 0.040 255 0.550 450 5.000 618 18.000 S Mid-Trip Handle, one per pole 045 0.045 260 0.600 455 5.500 620 20.000 T Mid-Trip, one per pole & Alarm Switch 050 0.050 265 0.650 460 6.000 622 22.000 055 0.055 270 0.700 465 6.500 624 24.000 060 0.060 275 0.750 470 7.000 625 25.000 2 3 POLES 065 0.065 280 0.800 475 7.500 630 30.000 1 One 3 Three 5 Five 070 0.070 285 0.850 480 8.000 635 35.000 2 Two 4 Four 6 Six 075 0.075 290 0.900 485 8.500 640 40.000 080 0.080 295 0.950 490 9.000 650 50.000 9 085 0.085 410 1.000 495 9.500 660 60.000 3 4 4 CIRCUIT F Relay Trip (current) 9 090 0.090 512 1.250 610 10.000 670 70.000 3 4 A Switch Only (no coil) G Relay Trip (voltage) 9 095 0.095 415 1.500 710 10.500 680 80.000 4,5 B Series Trip (current) H Dual Coil with Shunt Trip 9 210 0.100 517 1.750 611 11.000 685 85.000 C Series Trip (voltage) Voltage Coil 9 215 0.150 420 2.000 711 11.500 690 90.000 4 4,5 D Shunt Trip (current) K Dual Coil with Relay Trip 9 220 0.200 522 2.250 612 12.000 695 95.000 4 E Shunt Trip (voltage) Voltage Coil 9 225 0.250 425 2.500 712 12.500 810 100.000 230 0.300 527 2.750 613 13.000 7 VOLTAGE COIL (NOMINAL RATED VOLTAGE) 5 AUXILIARY/ALARM SWITCH CODE RATING 0 without Aux Switch A06 6DC A32 32DC J12 12AC J65 65AC 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug A12 12DC A48 48DC J18 18AC K20 120AC 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. A18 18DC A65 65DC J24 24AC L40 240AC 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. A24 24DC J06 6AC J48 48AC (Gold Contacts) 15 6 FREQUENCY & DELAY 8 TERMINAL 3 10 12 03 DC 50/60Hz, Switch Only 30 DC 50/60Hz Instantaneous 1 Stud 10-32 6 Stud M6 7 11 13,15 10 DC Instantaneous 31 DC 50/60Hz Ultra Short 2 Screw 10-32 7 0.250 Double Click Connect 12 15 11 DC Ultra Short 32 DC 50/60Hz Short 3 Stud 1/4-20 9 7/16” Clip Terminal 11 14 12 DC Short 34 DC 50/60Hz Medium 4 Stud M5 x 0.8 A Plug-In Stud 11 11,15 14 DC Medium 36 DC 50/60Hz Long 5 Screw M5 x 0.8 C 5/16” Clip Terminal 8 16 DC Long 42 50/60Hz Short, Hi-Inrush 7 8 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 8 16 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 9 ACTUATOR COLOR & LEGEND 8 22 50/60Hz Short 52 DC Short, Hi-Inrush Actuator Color I-O ON-OFF Dual Legend Color 8 24 50/60Hz Medium 54 DC Medium, Hi-Inrush White A B 1 Black 26 50/60Hz Long 56 DC Long, Hi-Inrush Black C D 2 White Red F G 3 White Green H J 4 White Notes: Blue K L 5 White 1 Actuator Code: Yellow M N 6 Black A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. Gray P Q 7 Black B: Handle location as viewed from front of breaker: Orange R S 8 Black 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 17 5 pole - three handles at center poles 6 pole - four handles at center poles Black (short handle) T U 9 White S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip 10 MOUNTING/BARRIERS of the breaker. Available with circuit codes B & C. MOUNTING STYLE BARRIERS VOLTAGE 2 Standard multipole units have all poles identical except when specifying auxiliary Threaded Insert switch and/or mixed poles. 4 pole max w/VDE. 5th pole available as Series Trip w/ 1 6-32 x 0.195 inches no < 300 Voltage Coil only. 3 Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE A 6-32 X 0.195 inches yes < 300 18 Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to C 6-32 X 0.195 inches yes ≥ 300 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 2 ISO M3 x 5mm no < 300 For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. B ISO M3 x 5mm yes < 300 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit 18 D ISO M3 x 5mm yes ≥ 300 Codes D, F, H & K available up to 50 amps maximum Current Rating. Front panel Snap-In, 1.00” [25.4mm] wide bezel 5 Consult factory for available Dual Coil options, as special catalog number is 17 E with Handleguard no < 300 required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously and are rated for intermittent duty only. 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole 11 AGENCY APPROVAL breakers, one aux. switch is supplied, mounted in the extreme right pole. C UL Recognized, CSA Accepted 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. D VDE Certified, UL Recognized, CSA Accepted 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. E TUV Certified, UL Recognized, CSA Accepted 9 Current Ratings 60 - 70 are available up to four poles maximum. Ratings 71 - 100 H UL489 Construction: VDE Certified, UL Recognized, CSA Accepted are available up to two poles maximum. I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), CSA Accepted 10 Terminal Code 1 available to 60 amps maximum. L UL489 Construction: UL Recognized, CSA Accepted 11 Terminal Codes 2, 4, 5 and C available to 50 amps maximum. R UL489 Construction: TUV Certified, UL Recognized, CSA Accepted 12 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 15 Terminal Codes 7, 9 & C are not VDE approved. 16 No marking available. Consult factory. VDE/TUV Approval requires dual (I-O, ON-OFF) or I-O markings on all handles. 17 Single pole only. 18 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 8 C-Series Handle UL489A Listed / Parallel Pole – Ordering Scheme C A 2 P 0 D4 820 3 2 1 M T 1 2 3 4 5 6 7 8 9 10 11 12 Terminal Actuator Mounting Max. App. Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Rating Approval Switch & Delay 6 8 TERMINAL 1 SERIES 3 Stud 1/4-20 C 6 Stud M6 A Plug-In Stud 1 2 ACTUATOR A Handle, one per pole 2 S Mid-Trip Handle, one per pole 9 ACTUATOR COLOR T Mid-Trip, one per pole & Alarm Switch LEGEND ON-OFF Dual Legend Color White B 1 Black 4 3 POLES Black D 2 White 1 One 2 Two 3 Three Red G 3 White Green J 4 White Blue L 5 White 5 4 CIRCUIT Yellow N 6 Black B Series Trip P Series Trip (parallel pole) Gray Q 7 Black Orange S 8 Black 5 AUXILIARY/ALARM SWITCH 0 without Aux Switch 10 MOUNTING 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug Threaded Insert 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. 1 6-32 x 0.195 inches 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. 2 ISO M3 x 5mm (Gold Contacts) 11 MAXIMUM APPLICATION RATING 7 6 FREQUENCY & DELAY M 80 DC D1 DC Ultra Short 11 DC Ultra Short D2 DC Short 12 DC Short D4 DC Medium 14 DC Medium 8 12 AGENCY APPROVAL D6 DC Long 16 DC Long A Without Approval J UL489A Listed, TUV Certified T UL489A Listed 7 CURRENT RATING (AMPERES) K UL489A Listed, VDE Certified (up to 200 amps) CODE AMPERES 7 UL489A Listed, TUV Certified (up to 250 amps) 810 100.00 813 130.00 817 170.00 820 200.00 4 811 110.00 814 140.00 917 175.00 922 225.00 4 812 120.00 815 150.00 818 180.00 825 250.00 912 125.00 816 160.00 819 190.00 Notes: 1 Handle moves to Mid-Position only upon electrical trip of C/B when Actuator S is specified. When Actuator Code T is specified, handle moves to Mid Position and Alarm Switch actuates only upon electrical trip of C/B. 2 Standard Handle colors are White, Black, Red & Yellow. 3 Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line and Load Terminals. For Terminal Code A, Line and Load Terminals must be connected to a copper bus bar having a minimum cross-section of 0.078 square inches. Terminal code A not available on the single pole unit. 4 Rating for 101 to 125 amps are available in 1 pole size. Ratings from 110 to 200 amps are available in 2-pole size. For ratings from 225-250 amps, specify 3-pole size. 5 Circuit code B only available with 1 pole. 6 1 pole only available with terminal codes 3 and 6. 7 Delays 11, 12, 14, and 16 are only available with 1 pole. 8 Agency code K and 7 not available with 1 pole. Agency code J only available with 1 pole. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Rocker UL489A Listed / Parallel Pole – Ordering Scheme 9 C 1 2 P 0 D4 820 3 1 A M T 1 2 3 4 5 6 7 8 9 10 11 12 Terminal Actuator Mounting Max. App. Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Rating Approval Switch & Delay 4 8 TERMINAL 1 SERIES 3 Stud 1/4-20 C 6 Stud M6 A Plug-In Stud 2 ACTUATOR C Curved Rocker, Two Color Visi, Indicate On, Vertical Legend D Curved Rocker, Two Color Visi, Indicate On, Horizontal Legend 9 ACTUATOR COLOR F Curved Rocker, Two Color Visi, Indicate Off, Vertical Legend LEGEND G Curved Rocker, Two Color Visi, Indicate Off, Horizontal Legend ON-OFF Dual Legend Color J Curved Rocker, Single Color, Vertical Legend White B 1 Black K Curved Rocker, Single Color, Horizontal Legend Black D 2 White 1 Flat Rocker, Two Color Visi, Vertical Legend Red G 3 White 2 Flat Rocker, Two Color Visi, Horizontal Legend Green J 4 White 3 Flat Rocker, Single Color, Vertical Legend Blue L 5 White 4 Flat Rocker, Single Color, Horizontal Legend Yellow N 6 Black 5 Flat Rocker, Push To Reset, Two Color Visi, Vertical Legend Gray Q 7 Black 6 Flat Rocker, Push To Reset, Two Color Visi, Horizontal Legend Orange S 8 Black 7 Flat Rocker, Push To Reset, Single Color, Vertical Legend 8 Flat Rocker, Push To Reset, Single Color, Horizontal Legend 10 MOUNTING ROCKER / MOUNTING INSERT STYLE 2 3 POLES A Standard Rocker Bezel - 6-32 Inserts 1 One 2 Two 3 Three B Standard Rocker Bezel - M3 Inserts C Rocker Guard Bezel - 6-32 Inserts D Rocker Guard Bezel - M3 Inserts 3 4 CIRCUIT E Standard Bezel with recessed Off Side Flat Rocker - 6-32 Inserts B Series Trip P Series Trip (parallel pole) F Standard Bezel with recessed Off Side Flat Rocker - M3 Inserts G Push to Reset Bezel - 6-32 Inserts H Push to Reset Bezel - M3 Inserts 5 AUXILIARY/ALARM SWITCH 0 without Aux Switch 6 S.P.S.T., 0.139 Solder Lug 2 S.P.D.T., 0.110 Q.C. Term. 8 S.P.S.T., 0.187 Q.C. Term. 11 MAXIMUM APPLICATION RATING 3 S.P.D.T., 0.139 Solder Lug 9 S.P.D.T., 0.187 Q.C. Term. M 80 DC 4 S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 12 AGENCY APPROVAL A Without Approval 5 6 FREQUENCY & DELAY J UL489A Listed, TUV Certified D1 DC Ultra Short 11 DC Ultra Short T UL489A Listed D2 DC Short 12 DC Short 7 UL489A Listed, TUV Certified D4 DC Medium 14 DC Medium D6 DC Long 16 DC Long Notes: 1 Breakers with Terminal Codes 3 & 6 are supplied with bus bars connecting the Line and Load Terminals. For Terminal Code A, Line and Load Terminals must be 2 connected to a copper bus bar having a minimum cross-section of 0.078 square 7 CURRENT RATING (AMPERES) inches. Terminal code A not available on the single pole unit. CODE AMPERES 2 Ratings for 101 to 125 amps are availabe in 1-pole size. Ratings from 110 to 200 810 100.00 813 130.00 817 170.00 820 200.00 amps are available in 2-pole size. For ratings from 225-250 amps, specify 3-pole 811 110.00 814 140.00 917 175.00 922 225.00 size. 812 120.00 815 150.00 818 180.00 825 250.00 3 Circuit code B only available with 1-pole. 912 125.00 816 160.00 819 190.00 4 1 pole only available with terminal codes 3 and 6. 5 Delays 11, 12, 14, and 16 are only available with 1 pole. 6 Agency code K and 7 not available with 1 pole. Agency code J only available with 1 pole. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 10 C-Series Handle UL489 Listed – Ordering Scheme C A 3 B 0 14 450 1 2 1 K G 1 2 3 4 5 6 7 8 9 10 11 12 Terminal Actuator Mounting/ Max. App. Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Barriers Rating Approval Switch & Delay 5 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 210 0.100 295 0.950 470 7.000 618 18.000 215 0.150 410 1.000 475 7.500 620 20.000 1 2 ACTUATOR 220 0.200 512 1.250 480 8.000 622 22.000 A Handle, one per pole 225 0.250 415 1.500 485 8.500 624 24.000 B Handle, one per multipole unit 230 0.300 517 1.750 490 9.000 625 25.000 S Mid-Trip Handle, one per pole 235 0.350 420 2.000 495 9.500 630 30.000 T Mid-Trip, one per pole & Alarm Switch 240 0.400 522 2.250 610 10.000 635 35.000 245 0.450 425 2.500 710 10.500 640 40.000 250 0.500 527 2.750 611 11.000 660 60.000 2 3 POLES 255 0.550 430 3.000 711 11.500 670 70.000 1 One 2 Two 3 Three 260 0.600 435 3.500 612 12.000 680 80.000 265 0.650 440 4.000 712 12.500 685 85.000 270 0.700 445 4.500 613 13.000 690 90.000 4 CIRCUIT 275 0.750 450 5.000 614 14.000 695 95.000 B Series Trip (current) 280 0.800 455 5.500 615 15.000 810 100.000 285 0.850 460 6.000 616 16.000 290 0.900 465 6.500 617 17.000 3 5 AUXILIARY/ALARM SWITCH 0 without Aux Switch 6 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 8 TERMINAL 7 9 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. 1 Stud 10-32 6 Stud M6 8 9 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. 2 Screw 10-32 9 7/16” Clip Terminal 9 10 (Gold Contacts) 3 Stud 1/4-20 A Plug-In Stud 8 8 4 Stud M5 x 0.8 C 5/16” Clip Terminal 8 5 Screw M5 x 0.8 6 FREQUENCY & DELAY 11 DC Ultra Short 26 50/60Hz Long 4 12 DC Short 42 50/60Hz Short, Hi-Inrush 11 9 ACTUATOR COLOR & LEGEND 4 14 DC Medium 44 50/60Hz Medium, Hi-Inrush Actuator Color ON-OFF Dual Legend Color 4 16 DC Long 46 50/60Hz Long, Hi-Inrush White B 1 Black 4 21 50/60Hz Ultra Short 52 DC Short, Hi-Inrush Black D 2 White 4 22 50/60Hz Short 54 DC Medium, Hi-Inrush Red G 3 White 4 24 50/60Hz Medium 56 DC Long, Hi-Inrush Green J 4 White Blue L 5 White Notes: Yellow N 6 Black 1 Actuator Code: Gray Q 7 Black A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. Orange S 8 Black B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 10 MOUNTING/BARRIERS 2 Standard multipole units have all poles identical except when specifying auxiliary 12 MOUNTING STYLE BARRIERS switch and/or mixed poles. Threaded Insert 2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating 1 6-32 x 0.195 inches yes code C) applications, have all poles identical except when specifying auxiliary / 2 ISO M3 x 5mm yes alarm switch which is normally supplied in extreme right pole per figure B. Terminal barriers are required on all multipole breakers. Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd pole has the same construction as poles 1 & 2. 11 MAXIMUM APPLICATION RATING 3 On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme A 65 DC right pole. VDE approval on auxiliary switch codes 2, 3 & 4 only. B 125 DC 2 Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit, C 120/240 AC only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC, D 240 AC and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit K 120 AC breaker, is supplied from factory with common terminal of auxiliary / alarm switch F 277 AC connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated M 80 DC 120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common terminal connected to breaker line terminal. Consult factory for special catalog number. 11 12 AGENCY APPROVAL 4 Available up to 50 amps maximum. 5 Current ratings 71 - 100 with VDE approvals are available up to two poles A w/o approvals maximum. F UL489 Listed, CSA Certified & VDE Certified 6 Terminal Codes 9 & C are not VDE approved. G UL489 Listed & CSA Certified 7 Terminal Code 1 available to 60 amps maximum. J UL489 Listed, CSA Certified & TUV Certified 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 9 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 10 Terminal Code A available to 100 amps maximum. 11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles. 12 Barriers supplied on multi-pole units only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Sealed Toggle UL Recognized – Ordering Scheme 11 C M 3 B 0 10 450 1 0 1 C 8 9 10 11 1 2 3 4 5 6 7 Terminal Legend Mounting Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Switch & Delay Plate Bezel/Barrier Approval 9 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 2 ACTUATOR 030 0.030 245 0.450 440 4.000 616 16.000 M Sealed Toggle, one per pole 035 0.035 250 0.500 445 4.500 617 17.000 040 0.040 255 0.550 450 5.000 618 18.000 045 0.045 260 0.600 455 5.500 620 20.000 050 0.050 265 0.650 460 6.000 622 22.000 3 POLES 055 0.055 270 0.700 465 6.500 624 24.000 1 One 2 Two 3 Three 060 0.060 275 0.750 470 7.000 625 25.000 065 0.065 280 0.800 475 7.500 630 30.000 3 070 0.070 285 0.850 480 8.000 635 35.000 4 CIRCUIT F Relay Trip (current) 2 3 075 0.075 290 0.900 485 8.500 640 40.000 A Switch Only (no coil) G Relay Trip (voltage) 3,4 080 0.080 295 0.950 490 9.000 650 50.000 B Series Trip (current) H Dual Coil with Shunt Trip 9 085 0.085 60.000 410 1.000 495 9.500 660 C Series Trip (voltage) Voltage Coil 9 3 3,4 090 0.090 670 70.000 512 1.250 610 10.000 D Shunt Trip (current) K Dual Coil with Relay Trip 9 3 095 0.095 680 80.000 415 1.500 710 10.500 E Shunt Trip (voltage) Voltage Coil 9 210 0.100 685 85.000 517 1.750 611 11.000 9 215 0.150 690 90.000 420 2.000 711 11.500 9 220 0.200 695 95.000 5 AUXILIARY/ALARM SWITCH 522 2.250 612 12.000 9 225 0.250 810 100.000 0 without Aux Switch 425 2.500 712 12.500 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 230 0.300 527 2.750 613 13.000 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. 7 VOLTAGE COIL (NOMINAL RATED VOLTAGE) 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. CODE RATING (Gold Contacts) A06 6DC A32 32DC J12 12AC J65 65AC A12 12DC A48 48DC J18 18AC K20 120AC A18 18DC A65 65DC J24 24AC L40 240AC 6 FREQUENCY & DELAY A24 24DC J06 6AC J48 48AC 2 03 DC 50/60Hz, Switch Only 30 DC 50/60Hz Instantaneous 6 10 DC Instantaneous 31 DC 50/60Hz Ultra Short 11 DC Ultra Short 32 DC 50/60Hz Short 8 TERMINAL 12 DC Short 34 DC 50/60Hz Medium 9 11 1 Stud 10-32 6 Stud M6 14 DC Medium 36 DC 50/60Hz Long 10 12 2 Screw 10-32 7 0.250 Double Click Connect 7 16 DC Long 42 50/60Hz Short, Hi-Inrush 11 11 3 Stud 1/4-20 9 7/16” Clip Terminal 6 7 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 10 13 4 Stud M5 x 0.8 A Plug-In Stud 7 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 10 10 5 Screw M5 x 0.8 C 5/16” Clip Terminal 7 22 50/60Hz Short 52 DC Short, Hi-Inrush 7 24 50/60Hz Medium 54 DC Medium, Hi-Inrush 26 50/60Hz Long 56 DC Long, Hi-Inrush 9 LEGEND PLATE 0 No Legend Notes: 1 Actuator Code M: Handle location as viewed from front of breaker: 2 pole - right pole 3 pole - center pole 2 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE. 10 MOUNTING/BARRIERS For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current MOUNTING STYLE BARRIERS Code 650. For 55-70 amps, select Current Code 670. For 75-100 amps, select 1 Standard Hex Nut no Current Code 810. A Standard Hex Nut (multi-pole units only) yes 3 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. 4 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip 11 AGENCY APPROVAL instantaneously and are rated for intermittent duty only. C UL Recognized & CSA Accepted 5 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole L UL Recognized & CSA Accepted with listed construction breakers, one aux. switch is supplied, mounted in the extreme right pole. T UL Recognized & CSA Accepted, UL1500 ignition protection 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 7 Available with Circuit Codes B & D only, and up to 50 amps maximum. 8 Consult factory for current ratings 71-100, in three pole units, available as special catalog number only. 9 Terminal Code 1 available to 60 amps maximum. 10 Terminal Codes 2, 4, 5 and C available to 50 amps maximum. 11 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 12 Terminal Code 7 available to 25 amps maximum. 13 Terminal Code A available to 100 amps maximum. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 12 C-Series Rocker UL Recognized – Ordering Scheme 14 450 C C 3 B 0 1 2 1 D 6 7 8 9 10 11 1 2 3 4 5 Frequency Current Rating Terminal Actuator Mounting/ Agency Series Actuator Poles Circuit Aux/Alarm & Delay Switch Color Barriers Approval 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 1 2 ACTUATOR Single color 030 0.030 245 0.450 440 4.000 616 16.000 035 0.035 250 0.500 445 4.500 617 17.000 Two Color Visi-Rocker J Vertical legend 040 0.040 255 0.550 450 5.000 618 18.000 C Indicate ON, vertical legend K Horizontal legend 045 0.045 260 0.600 455 5.500 620 20.000 D Indicate ON, horizontal legend L No legend 050 0.050 265 0.650 460 6.000 622 22.000 E Indicate ON, no legend Push-To-Reset, Single color 055 0.055 270 0.700 465 6.500 624 24.000 F Indicate OFF, vertical legend R Vertical legend 060 0.060 275 0.750 470 7.000 625 25.000 G Indicate OFF, horizontal legend U Horizontal legend 065 0.065 280 0.800 475 7.500 630 30.000 H Indicate OFF, no legend V No legend 070 0.070 285 0.850 480 8.000 635 35.000 Push-To-Reset, Visi-Rocker 075 0.075 290 0.900 485 8.500 640 40.000 N Indicate OFF, 080 0.080 295 0.950 490 9.000 650 50.000 vertical legend 9 085 0.085 410 1.000 495 9.500 660 60.000 O Indicate OFF, 9 090 0.090 512 1.250 610 10.000 670 70.000 horizontal legend 9 095 0.095 415 1.500 710 10.500 680 80.000 P Indicate OFF, 9 210 0.100 517 1.750 611 11.000 685 85.000 no legend 9 215 0.150 420 2.000 711 11.500 690 90.000 9 220 0.200 522 2.250 612 12.000 695 95.000 9 225 0.250 425 2.500 712 12.500 810 100.000 230 0.300 527 2.750 613 13.000 7 VOLTAGE COIL (NOMINAL RATED VOLTAGE) CODE RATING A06 6DC A32 32DC J12 12AC J65 65AC 2 3 POLES A12 12DC A48 48DC J18 18AC K20 120AC A18 18DC A65 65DC J24 24AC L40 240AC 1 One 2 Two 3 Three A24 24DC J06 6AC J48 48AC 4 4 CIRCUIT F Relay Trip (Current) 3 4 A Switch Only (No Coil) G Relay Trip (Voltage) 8 TERMINAL 4,5 10 12 B Series Trip (Current) H Dual Coil with Shunt Trip 1 Stud 10-32 6 Stud M6 11 13 C Series Trip (Voltage) Voltage Coil 2 Screw 10-32 7 0.250 Double Quick Connect 4 4,5 12 D Shunt Trip (Current) K Dual Coil with Relay Trip 3 Stud 1/4-20 9 7/16” Clip Terminal 4 11 14 E Shunt Trip (Voltage) Voltage Coil 4 Stud M5 x 0.8 A Plug-In Stud 11 5 Screw M5 x 0.8 C 5/16” Clip Terminal 6 5 AUXILIARY/ALARM SWITCH 0 without Aux Switch 16,17,18 9 ACTUATOR COLOR & LEGEND 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug Actuator or 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. Visi-Color Marking: Marking Color: 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. Single Color (Gold Contacts) Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker White A B 1 Black White Black C D 2 White n/a 6 FREQUENCY & DELAY Red F G 3 White Red 03 DC 50/60Hz, Switch Only 30 DC 50/60Hz Instantaneous Green H J 4 White Green 7 10 DC Instantaneous 31 DC 50/60Hz Ultra Short Blue K L 5 White Blue 11 DC Ultra Short 32 DC 50/60Hz Short Yellow M N 6 Black Yellow 12 DC Short 34 DC 50/60Hz Medium Gray P Q 7 Black Gray 14 DC Medium 36 DC 50/60Hz Long Orange R S 8 Black Orange 8 16 DC Long 42 50/60Hz Short, Hi-Inrush 7 8 20 50/60Hz Instantaneous 44 50/60Hz Medium, Hi-Inrush 8 21 50/60Hz Ultra Short 46 50/60Hz Long, Hi-Inrush 1 10 MOUNTING/BARRIERS 8 22 50/60Hz Short 52 DC Short, Hi-Inrush STANDARD ROCKER BEZEL BARRIERS VOLTAGE 8 24 50/60Hz Medium 54 DC Medium, Hi-Inrush 1 6-32 x 0.195 inches no <300 8 26 50/60Hz Long 56 DC Long, Hi-Inrush 2 6-32 x 0.195 inches yes <300 19 3 6-32 x 0.195 inches yes ≥300 Notes: 4 ISO M3 x 5mm no <300 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all poles identical except when specifying Aux. switch and/ 5 ISO M3 x 5mm yes <300 19 or mixed poles, and have one rocker per breaker. Rocker location as viewed from 6 ISO M3 x 5mm yes ≥300 front panel: 2 pole – left pole; 3 pole – center pole. ROCKERGUARD BEZEL 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE A 6-32 x 0.195 inches no <300 Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to C 6-32 x 0.195 inches yes <300 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 19 E 6-32 x 0.195 inches yes ≥300 For 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. G ISO M3 x 5mm no <300 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit J ISO M3 x 5mm yes <300 Codes D,F,H & K available up to 50 amps maximum Current Rating. 19 L ISO M3 x 5mm yes ≥300 5 Consult factory for available Dual Coil options, as special catalog number is PUSH-TO-RESET BEZEL required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously B 6-32 x 0.195 inches no <300 on line voltage. Dual Coil Voltage Coils require 30VA minimum power to trip D 6-32 x 0.195 inches yes <300 instantaneously and are rated for intermittent duty only. 19 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole F 6-32 x 0.195 inches yes ≥300 breakers, one aux. switch is supplied, mounted in the extreme right pole. Auxiliary H ISO M3 x 5mm no <300 switch codes 2, 3 & 4 are VDE approved. J ISO M3 x 5mm yes <300 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 19 M ISO M3 x 5mm yes ≥300 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. 9 Current Ratings 60-70 are available up to four poles maximum. Ratings 71-100 are available up to two poles maximum. 10 Terminal Code 1 available to 60 amps maximum. 11 AGENCY APPROVAL 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. C UL Recognized & CSA Accepted 13 Terminal Code 7 available to 25 amps maximum. D VDE Certified, UL Recognized & CSA Accepted 14 Terminal Code A available to 100 amps maximum. E TUV Certified, UL Recognized & CSA Accepted 15 Terminal Codes 7, 9 & C are not VDE approved. H UL489 Construction: VDE Certified, UL Recognized & CSA Accepted 16 Color shown is visi and legend with remainder of rocker black I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted 17 Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered. Dual = ON-OFF/I-O legend with actuator codes C - G, and J, K, N, O, R, & U. None L UL489 Construction: UL Recognized & CSA Accepted = no legend with actuator codes H, L, P, V. Rockerguard available with actuator R UL489 Construction: TUV Certified, UL Recognized & CSA Accepted codes C - L. Push-to-reset available with actuator codes N, O, P, R, U, V. 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 - 4 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Rocker UL Listed – Ordering Scheme 13 C C 3 B 0 14 450 1 2 A K G 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Max. App. Agency Color Barriers Rating Approval Switch & Delay 4 7 CURRENT RATING (AMPERES) 1 SERIES CODE AMPERES C 210 0.100 295 0.950 470 7.000 618 18.000 215 0.150 410 1.000 475 7.500 620 20.000 1 2 ACTUATOR 220 0.200 512 1.250 480 8.000 622 22.000 Two Color Visi-Rocker 225 0.250 415 1.500 485 8.500 624 24.000 C Indicate ON, vertical legend Single color 230 0.300 517 1.750 490 9.000 625 25.000 D Indicate ON, horizontal legend J Vertical legend 235 0.350 420 2.000 495 9.500 630 30.000 F Indicate OFF, vertical legend K Horizontal legend 240 0.400 522 2.250 610 10.000 635 35.000 G Indicate OFF, horizontal legend 245 0.450 425 2.500 710 10.500 640 40.000 250 0.500 527 2.750 611 11.000 650 50.000 ROCKER STYLE DESCRIPTIONS 255 0.550 430 3.000 711 11.500 660 60.000 INDICATE "ON" INDICATE "OFF" SINGLE COLOR 260 0.600 435 3.500 612 12.000 670 70.000 CODE "C" CODE "F" CODE "J" LINE 265 0.650 440 4.000 712 12.500 680 80.000 270 0.700 445 4.500 613 13.000 685 85.000 275 0.750 450 5.000 614 14.000 690 90.000 INDICATE COLOR 280 0.800 455 5.500 615 15.000 695 95.000 LINE LINE LOCATION 285 0.850 460 6.000 616 16.000 810 100.000 CODE "D" CODE "G" CODE "K" 290 0.900 465 6.500 617 17.000 LINE LINE LINE 8 TERMINAL 5 7 1 Stud 10-32 6 Stud M6 6 7,8 2 Screw 10-32 w/saddle & 9 7/16” Clip Terminal 1 7,8 3 POLES washer clamps A Plug-In Stud 7 6,8 1 One 2 Two 3 Three 3 Stud 1/4-20 C 5/16” Clip Terminal 6 4 Stud M5 x 0.8 6 5 Screw M5 x 0.8 w/saddle & 4 CIRCUIT washer clamps B Series Trip (current) 11 9 ACTUATOR COLOR & LEGEND 2 5 AUXILIARY/ALARM SWITCH Actuator or 0 without Aux Switch Visi-Color Marking: Marking Color: 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug Single Color 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. 10 Color: ON-OFF Dual Rocker/Handle Visi-Rocker 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. White B 1 Black White (Gold Contacts) Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue 6 FREQUENCY & DELAY 26 50/60Hz Long 8 Yellow N 6 Black Yellow 11 DC Ultra Short 42 50/60Hz Short, Hi-Inrush Gray Q 7 Black Gray 8 12 DC Short 44 50/60Hz Medium, Hi-Inrush Orange S 8 Black Orange 8 14 DC Medium 46 50/60Hz Long, Hi-Inrush 8 16 DC Long 52 DC Short, Hi-Inrush 8 21 50/60Hz Ultra Short 54 DC Medium, Hi-Inrush 12 10 MOUNTING/BARRIERS 22 50/60Hz Short 56 DC Long, Hi-Inrush 13 Standard Rocker Bezel BARRIERS 24 50/60Hz Medium Threaded Insert, 2 per pole A 6-32 X 0.195 inches yes Notes: C ISO M3 x 5mm yes 1 Multi-pole breakers have all breakers identical except when specifying Aux. switch Rockerguard Bezel and/or mixed poles, and have one rocker per breaker. Threaded Insert, 2 per pole 2 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right B 6-32 x 0.195 inches yes pole. D ISO M3 x 5mm yes 3 Available up to 50 amps maximum. 4 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 5 Terminal Code 1 available to 60 amps maximum. 6 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 11 MAXIMUM APPLICATION RATING 7 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. A 65 DC 8 Terminal Codes 9 & C are not VDE approved. B 125 DC 9 Color shown is visi and legend with remainder of rocker black 14 C 120/240 AC 10 Dual = ON-OFF/I-O legend on actuator. 11 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. D 240 AC 12 Rockerguard available with all actuator codes. F 277 AC 13 Barriers supplied on multi-pole units only. K 120 AC 14 2 & 3 pole circuit breakers required for 120/240 AC rating. M 80 DC 12 AGENCY APPROVAL A without approvals F UL 489 Listed, CSA Certified, & VDE Certified G UL 489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com HORIZONTAL VERTICAL STYLE STYLE | 14 C-Series Flat Rocker UL Recognized – Ordering Scheme C 1 2 B 0 10 450 1 2 1 E 1 2 3 4 5 6 7 8 9 10 11 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting/ Agency Switch & Delay Color Barriers Approval 9 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 030 0.030 245 0.450 440 4.000 616 16.000 1 2 ACTUATOR 035 0.035 250 0.500 445 4.500 617 17.000 Two Color Visi-Rocker 040 0.040 255 0.550 450 5.000 618 18.000 1 Indicate OFF, vertical legend 045 0.045 260 0.600 455 5.500 620 20.000 2 Indicate OFF, horizontal legend 050 0.050 265 0.650 460 6.000 622 22.000 Single color 055 0.055 270 0.700 465 6.500 624 24.000 3 Vertical legend 060 0.060 275 0.750 470 7.000 625 25.000 065 0.065 280 0.800 475 7.500 630 30.000 4 Horizontal legend 070 0.070 285 0.850 480 8.000 635 35.000 Push-To-Reset, Visi-Rocker 075 0.075 290 0.900 485 8.500 640 40.000 5 Indicate OFF, vertical legend 080 0.080 295 0.950 490 9.000 650 50.000 6 Indicate OFF, horizontal legend 9 085 0.085 410 1.000 495 9.500 660 60.000 Push-To-Reset , Single color 9 090 0.090 512 1.250 610 10.000 670 70.000 7 Vertical legend 9 095 0.095 415 1.500 710 10.500 680 80.000 9 8 Horizontal legend 210 0.100 517 1.750 611 11.000 685 85.000 9 215 0.150 420 2.000 711 11.500 690 90.000 9 220 0.200 522 2.250 612 12.000 695 95.000 2 9 3 POLES 225 0.250 425 2.500 712 12.500 810 100.000 230 0.300 527 2.750 613 13.000 1 One 2 Two 3 Three 7 VOLTAGE COIL (NOMINAL RATED VOLTAGE) CODE RATING 4 A06 6DC A32 32DC J12 12AC J65 65AC 4 CIRCUIT F Relay Trip (Current) 3 4 A12 12DC A48 48DC J18 18AC K20 120AC A Switch Only (No Coil) G Relay Trip (Voltage) 4,5 A18 18DC A65 65DC J24 24AC L40 240AC B Series Trip (Current) H Dual Coil with Shunt Trip A24 24DC J06 6AC J48 48AC C Series Trip (Voltage) Voltage Coil 4 4,5 D Shunt Trip (Current) K Dual Coil with Relay Trip 4 E Shunt Trip (Voltage) Voltage Coil 8 TERMINAL 10 12 1 Stud 10-32 6 Stud M6 11 13 2 Screw 10-32 7 0.250 Double Quick Connect 6 5 AUXILIARY/ALARM SWITCH 12 15 3 Stud 1/4-20 9 7/16” Clip Terminal 0 without Aux Switch 11 14 4 Stud M5 x 0.8 A Plug-In Stud 11 15 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 5 Screw M5 x 0.8 C 5/16” Clip Terminal 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. (Gold Contacts) 16,17,18 9 ACTUATOR COLOR & LEGEND Actuator or Visi-Color Marking: Marking Color: 6 FREQUENCY & DELAY 30 DC 50/60Hz Instantaneous 03 DC 50/60Hz, Switch Only 31 DC 50/60Hz Ultra Short Single Color 7 10 DC Instantaneous 32 DC 50/60Hz Short Color: I-O ON-OFF Dual/None Rocker/Handle Visi-Rocker 11 DC Ultra Short 34 DC 50/60Hz Medium White A B 1 Black White 12 DC Short 36 DC 50/60Hz Long Black C D 2 White n/a 8 Red F G 3 White Red 14 DC Medium 42 50/60Hz Short, Hi-Inrush 8 Green H J 4 White Green 16 DC Long 44 50/60Hz Medium, Hi-Inrush Blue K L 5 White Blue 7 8 20 50/60Hz Instantaneous 46 50/60Hz Long, Hi-Inrush Yellow M N 6 Black Yellow 8 21 50/60Hz Ultra Short 52 DC Short, Hi-Inrush Gray P Q 7 Black Gray 8 22 50/60Hz Short 54 DC Medium, Hi-Inrush Orange R S 8 Black Orange 8 24 50/60Hz Medium 56 DC Long, Hi-Inrush 26 50/60Hz Long 1 Notes: 10 MOUNTING/BARRIERS 1 Push-to-reset actuators have OFF portion of rocker shrouded. STANDARD ROCKER BEZEL BARRIERS VOLTAGE 2 Multi-pole breakers have all poles identical except when specifying Aux. switch and/or 1 6-32 x 0.195 inches no <300 mixed poles, and have one rocker per breaker. Rocker location as viewed from front 2 6-32 x 0.195 inches yes <300 panel: 2 pole – left pole; 3 pole – center pole. 19 3 6-32 x 0.195 inches yes ≥300 3 Switch Only circuits, rated up to 50 amps and 3 poles, and only available with VDE 4 ISO M3 x 5mm no <300 Certification when tied to a protected pole (Circuit Code B, C, D or H.). For .02 to 30 5 ISO M3 x 5mm yes <300 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. For 19 6 ISO M3 x 5mm yes ≥300 55-70 amps, select Current Code 670. For 75-100 amps, select Current Code 810. RECESSED OFF ROCKER 4 Circuit Codes D,E,F,G,H & K available with Terminal Codes 1,2,4 & 5 only. Circuit 7 6-32 x 0.195 inches no <300 Codes D,F,H & K available up to 50 amps maximum Current Rating. 8 6-32 x 0.195 inches yes <300 5 Consult factory for available Dual Coil options, as special catalog number is required. Dual Coil Voltage Coils with Shunt Trip Construction trip instantaneously on line 9 6-32 x 0.195 inches yes ≥300 voltage. Dual Coil Voltage Coils require 30VA minimum power to trip instantaneously A ISO M3 x 5mm no <300 and are rated for intermittent duty only. C ISO M3 x 5mm yes <300 6 Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole E ISO M3 x 5mm yes ≥300 breakers, one aux. switch is supplied, mounted in the extreme right pole. Auxilary PUSH-TO-RESET BEZEL switch codes 2, 3 & 4 are VDE approved. B 6-32 x 0.195 inches no <300 7 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. D 6-32 x 0.195 inches yes <300 8 Available with Circuit Codes B & D only, and up to 50 amps maximum. 19 F 6-32 x 0.195 inches yes ≥300 9 Current ratings 60-70 are available up to four poles maximum. Current ratings 71 - H ISO M3 x 5mm no <300 100 are available up to two poles maximum. J ISO M3 x 5mm yes <300 10 Terminal Code 1 available to 60 amps maximum. 19 M ISO M3 x 5mm yes ≥300 11 Terminal Codes 2,4,5 & C available to 50 amps maximum. 12 Terminal Codes 3,6 & 9 available to 100 amps maximum. 13 Terminal Code 7 available to 25 amps maximum. 14 Terminal Code A available to 100 amps maximum. 11 AGENCY APPROVAL 15 Terminal Codes 7, 9 & C are not VDE approved. 16 Color shown is visi & legend with remainder of rocker black. Dual = ON-OFF/I-O C UL Recognized & CSA Accepted legend. E TUV Certified, UL Recognized & CSA Accepted 17 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted 8. Legend on Push-to-reset bezel/shroud matches visi-color of rocker with actuator L UL489 Construction: UL Recognized & CSA Accepted codes 5 & 6. R UL489 Construction: TUV Certified, UL Recognized & CSA Accepted 18 VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. 19 VDE/TUV: 30 amps max.; UL/CSA: 50 amps max.; Available in 2 & 3 poles only and limited to AC Delays. “General Purpose amps” not rated for “full load amps” or to be used in applications with a motor. 20 Recessed “OFF SIDE” available with actuator codes 1,2,3&4. Legends on rocker are available in ink stamping only. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Flat Rocker UL Listed – Ordering Scheme 15 C 1 2 B 0 14 450 1 2 A K G 1 2 3 4 5 6 7 8 9 10 11 12 Terminal Actuator Mounting/ Max. App. Agency Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Color Barriers Rating Approval Switch & Delay 5 1 SERIES 7 CURRENT RATING (AMPERES) CODE AMPERES C 210 0.100 295 0.950 470 7.000 618 18.000 215 0.150 410 1.000 475 7.500 620 20.000 1 2 ACTUATOR 220 0.200 512 1.250 480 8.000 622 22.000 Two Color Visi-Rocker 225 0.250 415 1.500 485 8.500 624 24.000 1 Indicate OFF, vertical legend 230 0.300 517 1.750 490 9.000 625 25.000 2 Indicate OFF, horizontal legend 235 0.350 420 2.000 495 9.500 630 30.000 Single color 240 0.400 522 2.250 610 10.000 635 35.000 3 Vertical legend 245 0.450 425 2.500 710 10.500 640 40.000 4 Horizontal legend 250 0.500 527 2.750 611 11.000 650 50.000 Push-To-Reset, Visi-Rocker 255 0.550 430 3.000 711 11.500 660 60.000 5 Indicate OFF, vertical legend 260 0.600 435 3.500 612 12.000 670 70.000 6 Indicate OFF, horizontal legend 265 0.650 440 4.000 712 12.500 680 80.000 Push-To-Reset , Single color 270 0.700 445 4.500 613 13.000 685 85.000 7 Vertical legend 275 0.750 450 5.000 614 14.000 690 90.000 8 Horizontal legend 280 0.800 455 5.500 615 15.000 695 95.000 285 0.850 460 6.000 616 16.000 810 100.000 290 0.900 465 6.500 617 17.000 2 3 POLES 1 One 2 Two 3 Three 8 TERMINAL 7 9 1 Stud 10-32 6 Stud M6 8 9,10 4 CIRCUIT 2 Screw 10-32 9 7/16” Clip Terminal 9 9 B Series Trip (current) 3 Stud 1/4-20 A Plug-In Stud 8 8,10 4 Stud M5 x 0.8 C 5/16” Clip Terminal 8 5 Screw M5 x 0.8 2 5 AUXILIARY/ALARM SWITCH 0 without Aux Switch 12 2 S.P.D.T., 0.110 Q.C. Term. 6 S.P.S.T., 0.139 Solder Lug 9 ACTUATOR COLOR & LEGEND 3 S.P.D.T., 0.139 Solder Lug 8 S.P.S.T., 0.187 Q.C. Term. Actuator or 4 S.P.D.T., 0.110 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. Visi-Color Marking: Marking Color: (Gold Contacts) Single Color 11 Color: ON-OFF Dual Rocker/Handle Visi-Rocker White B 1 Black White 6 FREQUENCY & DELAY Black D 2 White n/a 11 DC Ultra Short 26 50/60Hz Long Red G 3 White Red 4 12 DC Short 42 50/60Hz Short, Hi-Inrush Green J 4 White Green 4 14 DC Medium 44 50/60Hz Medium, Hi-Inrush Blue L 5 White Blue 4 16 DC Long 46 50/60Hz Long, Hi-Inrush Yellow N 6 Black Yellow 4 21 50/60Hz Ultra Short 52 DC Short, Hi-Inrush Gray Q 7 Black Gray 4 22 50/60Hz Short 54 DC Medium, Hi-Inrush Orange S 8 Black Orange 4 24 50/60Hz Medium 56 DC Long, Hi-Inrush 1 Notes: 12 10 MOUNTING/BARRIERS 2 Push-to-reset actuators have OFF portion of rocker shrouded. 15 3 Multi-pole breakers have all breakers identical except when specifying Aux. switch STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole and/or mixed poles, and have one rocker per breaker. A 6-32 X 0.195 inches yes 4 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. C ISO M3 x 5mm yes 14 5 Available up to 50 amps maximum. RECESSED OFF ROCKER 6 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. Threaded Insert, 2 per pole 7 Terminal Code 1 available to 60 amps maximum. E 6-32 x 0.195 inches yes 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. F ISO M3 x 5mm yes 13 9 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. PUSH-TO-RESET BEZEL 10 Terminal Codes 9 & C are not VDE approved. Threaded Insert, 2 per pole 11 Color shown is visi and legend with remainder of rocker black B 6-32 x 0.195 inches yes 12 Dual = ON-OFF/I-O legend on actuator. D ISO M3 x 5mm yes 13 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. 14 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered. Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator 11 MAXIMUM APPLICATION RATING codes 15 5 & 6. A 65 DC 16 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker B 125 DC 16 are available in ink stamping only. C 120/240 AC 17 Barriers supplied on multi-pole units only. D 240 AC 18 2 & 3 pole circuit breakers required for 120/240 AC rating. F 277 AC K 120 AC M 80 DC 12 AGENCY APPROVAL A without approvals G UL 489 Listed & CSA Certified J UL489 Listed, CSA Certified & TUV Certified Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 16 C-Series Handle – Circuit & Terminal Diagrams .960 [24.38] .311 DIA [Ø7.90] .558 [14.17] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Available on Series Trip and Switch Only Circuits when called for on multi-pole units. Only one aux. switch is normally supplied, as viewed in mulit-pole identification scheme. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Handle – Circuit & Terminal Diagrams 17 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuits. 4 Available only as special catalog number. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 18 C-Series Handle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Handleguard – Form & Fit Drawings 19 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 20 C-Series Arc Chute Barrier UL Recognized/Listed – Form & Fit Drawings Notes: 1 Only 1-pole and 3-pole configurations shown. Arc chute (w/o barrier) and arc chute barrier also available for 2-pole construction. 2 Dimensions apply to all variations shown. 3 Notice that line and load terminal orientation for indicate on and indicate off rocker circuit breakers are opposite. 4 Screw type terminals shown for Rocker style (CF1, C11, etc) circuit breakers. For other terminal configurations see circuit and terminal diagrams. 5 All dimensions are in inches [millimeters]. 6 Tolerance ± .020 unless otherwise specified. 7 Must be ordered under a special catalog number. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Parallel Pole – Form & Fit Drawings 21 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 22 C-Series Sealed Toggle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Rocker – Circuit & Terminal Diagrams 23 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 24 C-Series Rocker – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | C-Series Flat Rocker – Form & Fit Drawings 25 Notes: 1 For pole orientation with horizontal legend, rotate front view clockwise 90°. 2 All dimensions are in inches [millimeters]. 3 Tolerance ±.020 [.51] unless otherwise specified. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com « « Alaska, Hawaii | 26 Reps & Contact Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. Matera Matera MIDWEST W. Canada E. Canada DM Michigan TEMCO Northwest WA ND NORTHERN Hanna Lind Ltd. MT ME VT WI MN Melody SD Sierra NH Emery MI LD. Allen OR ID Norris MA NY WY CT « IA IN DM Assoc PA RI Bridge Marketing NE East Pacent OH Omega Limited Dy-tronix Inc. DM NJ NV IL TSI North Assoc DE WV MD KS UT CO KY CA MO VA TSI TN NC Luscombe Signal OK WEST Enterprises Engineering SC AR Pinnacle Marketing AZ NM Sunbelt Components MS AL GA TX SOUTHEAST LA Matrix DM Mexico South America Mexico ProRep Solutions FL LATIN AMERICA Europe Asia-Pacific Americas Middle East Oceania Africa About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com « « | Notes 27 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 @ Email: sales carlingtech.com @ Northern Region Sales Office: nrsm carlingtech.com @ Southeast Region Sales Office: sersm carlingtech.com @ Midwest Region Sales Office: mrsm carlingtech.com @ West Region Sales Office: wrsm carlingtech.com @ Latin America Sales Office: larsm carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 @ Email: sales carlingtech.com.hk @ Shenzhen, China: shenzhen carlingtech.com @ Shanghai, China: shanghai carlingtech.com @ Pune, India: india carlingtech.com @ Kaohsiung, Taiwan: taiwan carlingtech.com @ Yokohama, Japan: japan carlingtech.com | | Europe Middle East Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 @ Email: ltd.sales carlingtech.com @ Germany: gmbh carlingtech.com @ France: sas carlingtech.com www.carlingtech.com REV_08_2015

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the CB2-B2-24-660-321-E?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker Hydraulic Magnetic 1Pole 30A 277VAC/80VDC AA1-A0-03-630-1C1-C

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...