Electronics Finder Manufacturers C CARLING TECHNOLOGIES CMB-053-27G6N-B-A/05
About product Specifications Datasheet FAQ

CARLING TECHNOLOGIES CMB-053-27G6N-B-A/05

Image of CARLING TECHNOLOGIES CMB-053-27G6N-B-A/05

Description

Circuit Breaker Thermal 1Pole 5A 125VAC/250VAC/32VDC

Part Number

CMB-053-27G6N-B-A/05

Price

Request Quote

Manufacturer

CARLING TECHNOLOGIES

Lead Time

Request Quote

Category

Circuit Protection »  Circuit Breaker

Specifications

Manufacturer

Carling Technologies

Manufacturers Part #

CMB-053-27G6N-B-A/05

Industry Aliases

CMB-053-27G6N-B-A/05

Sub-Category

Circuit Breakers

Factory Pack Quantity

1

Datasheet

pdf file

News-2007-Thermal-CP.pdf

1325 KiB

Extracted Text

Thermal Circuit Protectors Reliable, Cost-effective Circuit Protection TransformingCustomerNeeds intoCustomerSolutions AtCarlingTechnologies,wedomuchmorethanmanufactureelectricalcomponents.We engineerpowerfulsolutions.Workingcloselywithyourproductteam,wecantailorswitching andcircuitprotectionsolutionsthatmeetyourapplicationneeds—costeffectively. Sinceourfoundingin1920,therearefewproductswehavent ’ turnedon,fewerindustries thathavent ’ turnedtous.WithfiveISOcertifiedmanufacturinglocationsandtechnicalsales officesworldwide,CarlingTechnologiesnowranksamongtheworlds ’ largestprivately ownedmanufacturersofhydraulic/magneticcircuitbreakers,thermalcircuitprotectors,elec- tricalswitchesandassemblies,powerdistributioncentersandelectroniccontrolsystems.In regardtocircuitprotection,weleadtheindustryindeliveringhigherratingsinsmallerpack- ages.Andwhatmakesallourbreakersespeciallyattractiveistheirsuperiorperformance andreliability–––bothhallmarksofCarlingTechnologies. Wehaveover2000employeesworkingthroughofficesandmanufacturingsitesacrossthe globe,providingengineeredsolutionstoleadingelectronicandindustrialOEMsinavariety ofindustries,including: • Electronics(telecom,medical,computers,officeautomation) • IndustrialControls • Transportation(on/offroadvehicles,trucks,buses,boats) • Appliances • FactoryAutomation Welookforwardtohelpingyoucreatesafe,reliableproductsthatexceedthetough demandsoftodays ’ applications.Youl’lfindourcommitmenttoexcellenceconsistentlydeliv- ers“QualitybyDesign,”ourcompany’smission. Ourcommitmenttoqualityproductsbeginswithourinvestmentinresearchanddevelop- ment.NotonlydoesCarlinghaveateamofhighly-qualifiedengineersonstaff,weequip themwiththeindustry’smostadvancedcomputer-aideddesigntools. Ourengineeringteamwillworkcloselywithyourstoadvanceyourprojectfrominitialproduct conceptstofinaldesignandmanufacturing.Usingindustry-leadingCAD/CAMsoftware, Carlingengineerscanevaluatemultipledesignalternativesaswellasdevelopproducts, toolingandmanufacturingprocessesconcurrently.Theresult?Functionallysuperior,aes- theticallypleasingproducts––producedfasterandatalowercost. Wecanevenshareelectronicfilesthatcanbeeasilyincorporatedintotherestofyour design.Justonemorereasonyoul’l thinkofCarling asmuchmorethananapprovedvendor,but ratherasaprovenpartner. Ourautomatedcallcentersystemensures thatyourcallsareroutedtotheright CustomerCarepersonforpromptatten- tion. Ourcustomercarepersonnelare technicallytrainedtodiscussyour requirementsandprovidetheadviceand servicesyouexpectfromCarling Technologies. EachmemberoftheCarling CustomerCareteamistechnicallytrained onourstandardproducts,andApplication Engineersarealsoavailabletoansweryour moreadvancedtechnicalquestions.Inaddi- tion,Carlingisproudtoofferaglobalnet- workoffullytrainedrepresentativesanddis- tributors,whoarealwaysreadytoservice you. www.carlingtech.com CarlingTechnologies’Products Contents Withinthiscatalog,you’llfindourcurrentlineofthermalcircuit Page protectors,from3to60amps,whichofferreliable,costeffective circuitprotection.Wealsoofferacomprehensivelineof Introduction 2 hydraulic/magneticandequipmentleakagecircuitprotection, AvailableChoicesofCircuitProtection 2 electricalswitches,electroniccontrolsystemsandpowerdistri- butioncenters.Formoreinformationonourotherproducts, pleaserequestoneofthecatalogslistedontheinsideback ProductSpecifications&OrderingInformation coverofthiscatalog,orgotowww.carlingtech.com. CTB-Series 3 PanelMountRockerThermalCircuitProtector, HowToUseThisCatalog Ratingsupto16AAC/DC PleaserefertotheContents,locatedonthispage,forthetypeof breakerrequired.EachbreakerSeriesislocatedunderan CMB-Series 4 alphabeticalcode.Eachcoderefersyoutothespecificpages MiniaturePushbuttonThermalCircuitProtector, coveringanindividualSeries.Productfeatures/specifications Ratingsupto20AAC/DC anddimensionaldrawingsareprovidedtoassistyouwithprod- uctselection. CLB-Series 6 PushbuttonThermalCircuitProtector, Followoureasystep-by-stepcatalognumbersequencetocon- Ratingsupto60AAC/DC structthecircuitbreaker,whichmeetsyourneeds.Anordering formatandanexampleforconstructingacatalognumberare RegulatoryAgencies 8 providedforeachSeries. www.carlingtech.com Ourwebsitealsooffersafastandeasywayforyoutoview productpagesandpdffilesforyourthermalcircuitprotection needs.Astockcheckfeatureisalsoincludedat www.carlingtech.com.Productpages&PDFfilesmakethe CarlingTechnologies’websiteyour"onestopshop"forquick andthoroughproductinformation. CustomerCare Center WarrantyPolicy CarlingTechnologies,Inc.(Seller)warrantsthatgoodssoldhereundershallbefreeof Foradditionalapplicationassistance,weurgeyoutoconsultwith defectsinmaterialandworkmanshipforoneyearfromdateofshipment. ourexperiencedstaffinourCustomerCareCenter.Our Intheeventofsuchdefects,theSellers ’ onlyobligationshallbethereplacementorthe TechnicalandEngineeringstaffhasextensivetest,researchand costofthedefectivegoods,themselves,excluding,withoutlimitation,laborcosts,which areormayberequiredinconnectionwiththereplacementorreinstallationofthegoods. developmentcapabilities,andhaveassistedmanycustomersin ThiswarrantyistheSellers ’ soleobligationandexcludesallotherremediesorwarranties, solvinguniquedesignandapplicationproblemswithstandardor expressorimplied,includingwarrantiesofmerchantabilityandfitnessforaparticularpur- customizedproducts.Pleaserefertoourlocationlistingonthe pose,whetherornotpurposesorspecificationsaredescribedherein. ThisWarranty backofthiscatalog,forcontactinformationforyourarea. expresslyexcludesanyandallincidental,specialand/orconsequentialdamagesofany nature. Sellerfurtherdisclaimsanyresponsibilityforinjurytopersonordamagetoorloss Welookforwardtoworkingwithyou. ofpropertyorvaluecausedbyanyproductwhichhasbeensubjectedtomisuse,negli- gence,oraccident;ormisapplied,ormodifiedorrepairedbyapersonorpersonsnot authorizedbytheSellerorwhichhavebeenimproperlyinstalled. www.carlingtech.com 3 Introduction Anyelectricalorelectronicequipmentthatisdesignedwithout Specifyingacircuitprotectiondeviceforanapplicationisnota includingcircuitprotectionisanaccidentwaitingtohappen. difficulttask,butitwillrequiresomethought.Ifelectricaland Undernormaloperatingconditions,thismaynotappeartobe electronicequipmentisdesignedwithover-specifiedcircuit aproblem.However,normaloperatingconditionsarenot protectiondevicestheywillbevulnerabletothedamaging alwaysguaranteed.Understrainedorheavyuse,amotor effectsofpowersurgesandthecatastrophicresultsofafire; and/oranotherload-generatingcomponentwithintheequip- whileusingunder-specifiedcircuitprotectiondeviceswillresult mentwilldrawadditionalcurrentfromthepowersource;when innuisancetripping. thishappens,theequipments ’ wiresand/orcomponentswill overheatandmayultimatelyburnup.Also,powersurgesand Theshortcircuitcapacityofacircuitprotectiondeviceshould shortcircuitsinunprotectedequipmentcancauseextensive begreaterthanthecircuits ’ availableshortcircuitfaultcurrent. damagetotheequipmentandtotheconductorsleadingtothe AvailableshortcircuitcurrentisthemaximumRMScurrentthat equipment. wouldbepresentifalltheconductorsweretobeconnected directlytothefaultlocation.Inreality,thisisnotthecase.The Inadditiontoprotectingtheequipment,theentireelectrical actualshortcircuitcurrentismuchlessthantheavailableshort systemincludingthecontrolswitches,wires,andpowersource circuitcurrent.Theactualshortcircuitcurrentisreduceddueto mustbeprotectedfromfaults.Acircuitprotectiondevice thecombinedimpedanceoftheconductors,thesizeofthe shouldbeemployedatanypointwhereaconductorsize transformerandothercurrentrestrictingcomponentswithinthe changes.Manyelectroniccircuitsandcomponentsliketrans- circuit. formershavealoweroverloadwithstandthresholdlevelthan conductorssuchaswiresandcables.Thesecomponents Theapplications ’ environmentalconditionsmustbeconsidered requirecircuitprotectiondevicesfeaturingveryfastoverload whenselectingthepropercircuitprotectiondevice.Excessive sensingandopeningcapabilities. temperature,humidity,severevibrationandshockcancause adverseperformancecharacteristicsinmanytypesofcircuit protectiondevices.Forinstance,afuseelementislessreliable whenitishotthanwhenitiscold. AvailableChoicesofCircuitProtection CarlingTechnologiesoffersthreetypesofcircuitprotection hydraulic/magneticcircuitbreakercanbetailoredinfoursepa- devices:thermalcircuitprotectors,hydraulic/magneticcircuit rateareas:thedesiredcircuit;thetrippoint(inamperes);the protectors/breakersandequipmentleakagecircuitbreakers. timedelay(inseconds);andtheinrushhandlingcapacityof Thiscatalogfeaturesourthermalcircuitprotectionproductline. thebreaker.Thesefactorscanbevariedwithrelativelylittle Fordetailsrelatedtohydraulic/magneticcircuitprotectionand impactontheshortcircuitcapabilityofthebreaker.Typically, equipmentleakagecircuitbreakerproducts,pleaseseeour hydraulic/magneticcircuitbreakersareavailablewithachoice CircuitProtection403catalog. ofthreedifferenttriptime,delaycurves:slow,mediumand long.Thesechoicesprovidethedesignerwithahighlevelof Thermalcircuitprotectorsutilizeabimetallicstripelectricallyin designflexibilitywhenmatchingthebreakerstriptimedelay serieswiththecircuit.Theheatgeneratedbythecurrentdur- curvestoothercircuitprotectiondevicesinacascade,ordis- inganoverloaddeformsthebimetallicstripandtripsthe criminatingcircuit.Inaddition,specialhi-inrushconstructions breaker.Thermalprotectorshaveasignificantadvantageover areavailableforequipmentwithsevereinrushcharacteristics. fusesinthattheycanberesetaftertripping.Theycanalsobe usedasthemainON/OFFswitchfortheequipmentbeingpro- Equipmentleakagecircuitbreakersfunctionashydraulic/mag- tected. neticcircuitbreakers,offeringcustomizedoverloadandshort circuitprotection.Inaddition,theysenseandguardagainst Hydraulic/magneticcircuitprotectors/breakersprovidehighly faultstogroundusinginnovativeelectronicstechnologies.With precise,reliableandcosteffectivesolutionstomostdesign theexceptionofsmallamountsofleakage,thecurrentreturn- problems.Thehydraulic/magneticcircuitbreakerisconsidered ingtothepowersupplywillbeequaltothecurrentleavingthe tobetemperaturestableandthusisnotappreciablyaffected powersupply.Ifthedifferencebetweenthecurrentleavingand bychangesinambienttemperature.Its ’ over-currentsensing returningthroughtheearthleakagecircuitbreakerexceedsthe mechanismreactsonlytochangesofcurrentinthecircuit leakagesensitivitysetting,thebreakertripsandits ’ LEDillumi- beingprotected.Ithasno"warm-up"periodtoslowdownits nates.TheLEDgivesaclearindicationthatthetripoccurred responsetooverload.Ithasno"cool-down"periodafterover- asaresultofleakagetoground.Thisprotectionhelpsprevent loadbeforeitcanbereset.Thecharacteristicsofa seriousequipmentdamageandfire. 4 www.carlingtech.com CTB-Series Panel Mount Rocker Thermal Circuit Protector Rating: 3to16A,125,250VAC,50VDC Approvals: UL,CUL,VDE,CE Interruptingcapacity: 1000amps InsulationResistance: 100Mohms Applications: HouseholdAppliances Transportation Marine PowerStrips MedicalEquipment AudioVisualEquipment PowerSupplies ExerciseEquipment ROHSComplaint TripTimeinSeconds TripCurves RECOMMENDEDPANELTHICKNESS: .032-.062[.81-1.57] 1.Toadjustthebreakerratingforambienttemperature,multiplythebreakerratingbythefactor.(ex:5Aratingx.850=4.25A.Select4Arating.) - -- - -- CTB 05 B B B 1 2 3 4 5 Series Bezel Rocker Rating Panel Color Color Thickness 1SERIES 4RATING NOTES: Alldimensionsareininches CTB 03 3amp 08 8amp 14 14amp [millimeters]. 04 4amp 09 9amp 15 15amp Tolerance±.005[.127] 1 2BEZELCOLOR 05 5amp 10 10amp 16 16amp unlessotherwisespecified. B Black 06 6amp 12 12amp Breakermusthold100%of 07 7amp 13 13amp ratedcurrentandmusttripat 150%andabove,withinthe 1 3ROCKERCOLOR timelimitsshownincurve. 5PANELTHICKNESS B Black Triptimesspecifiedat25° blankfitsstandard thicknessof.032-.062 ambientwithnopreloading. B fits.070-.110panelthickness 1 Additionalcolors available.Consultfactory. www.carlingtech.com 5 Percentageof RatedCurrent CMB-Series Pushbutton Thermal Circuit Protector Rating: Voltagedrop: 3to20A,125-250VAC,32VDC <0.25V Approvals: Applications: UL,CUL,CSA,TUV,CE HouseholdAppliances UL1500/ISO8846forignition Transportation protection/marine Marine DielectricStrength: PowerStrips 2500VAC/1minute MedicalEquipment Interruptingcapacity: AudioVisualEquipment 2500amps PowerSupplies InsulationResistance: ROHSCompliant 100Mohms OperatingTemperature: -10°Cto60°C TripTimeinSeconds TripCurves Breakermusthold100%ofratedcurrentandmusttripat150%andabove,withinthetimelimitsshownincurve. Triptimesspecifiedat25°ambientwithnopreloading. 1. Toadjustthebreakerratingforambienttemperaturemultiplythebreakerratingbythefactor.(ex:5ampratingat0°C:5x.67=3.3amp.Select3amprating.) 4 www.carlingtech.com Percentageof RatedCurrent C CM MB B--S Se erriie es s P Pu us sh hb bu utttto on n T Th he errm ma all C Ciirrc cu uiitt P Prro otte ec ctto orr - - - - CMB 10 3 11 C 3 B B A /10 1 2 3 4 5 6 7 8 9 10 Series Rating Voltage Mounting Bushing Mounting Indicator Button Terminal ButtonMarking Hole Type Nut Plate 1SERIES CMB 2RATING 03 3amp 05 5amp 07 7amp 10 10amp 13 13amp 15 15amp 20 20amp 04 4amp 06 6amp 08 8amp 12 12amp 14 14amp 16 16amp 3VOLTAGE 3 125-250VAC/32VDC 4MOUNTINGHOLE 1 11 M11 2 12 M12 3 00 SnapInStyle 9 27 3/8”27UNS 12 28 3/8”27UNS (doubleflatted) 5BUSHING PLASTIC 4 C TypeC 4 D TypeD 5 E TypeE 8 G TypeG 6 H TypeH 13 K TypeK METAL 8 J TypeJ 7 6MOUNTINGNUT N None 1 Type1 2 Type2 11 3 Type3 4 Type4 5 Type5 14 6 Type6 9 7 Type7 9 NOTE:Type5isclearhexboot.Type8isblackhexboot(availableforbushingsE&Jonly);Type3nutincludesmoldedin“PRESSTORESET”marking. 8 Type8 7 7INDICATORPLATE N None A Embossed NOTES: B SilverPrinting Alldimensionsarein.[mm]. onBlack Tolerance±.005[.127]unlessotherwisespecified. 1 UsedwithbushingCorDonly. 2 UsedwithHbushingonly. Allindicatorplatesaremarked“circuitbreakerpresstoreset”. 3 UsedwithbushingEonly. 4 UsedwithM11mountingholeonly. 5 Usedwithmountinghole00only. 6 UsedwithM12mountingholeonly. 8BUTTON 7 Allhardwareavailableseparately. Consultfactory. 8 Availablewithmountinghole27only. B Black R Red W White 9 AvailablewithGorJbushingonly. 10 Ampratingmustmatchbuttonmarking(ex:20will 9TERMINAL bemarkedonthebuttonof CMB-203-27G3N-W-A/20) A TypeA 11 Includesmoldedin“PRESSTORESET”marking. B TypeB 12 AvailablewithKbushingonly. 13 Availablewithmountinghole28only. C TypeC 14 Thicknessis3.0mm,.118in. D TypeD E TypeE 10 10BUTTONMARKING(IFBLANK,NOMARKING.) ButtonMarkingOrientation: line 15 load 03 3amp 05 5amp 07 7amp 10 10amp 13 13amp 15 15amp 20 20amp 04 4amp 06 6amp 08 8amp 12 12amp 14 14amp 16 16amp www.carlingtech.com 5 CLB-Series Pushbutton Thermal Circuit Protector Rating: Voltagedrop: 3to60A,125-250VAC,32VDC <0.25V Approvals: Applications: UL,CUL,CSA,TUV,CE HouseholdAppliances UL1500/ISO8846forignition Transportation protection/marine Marine DielectricStrength: PowerStrips 2500VAC/1minute MedicalEquipment Interruptingcapacity: AudioVisualEquipment 2500amps PowerSupplies InsulationResistance: ROHSCompliant 100Mohms OperatingTemperature: -10°Cto60°C TripTimeinSeconds TripCurves Breakermusthold100%ofratedcurrentandmusttripat150%andabove,withinthetimelimitsshownincurve. Triptimesspecifiedat25°ambientwithnopreloading. 1 Toadjustthebreakerratingforambienttemperaturemultiplythebreakerratingbythefactor.(ex:5ampratingat0°C:5x.67=3.3amp.Select3amprating.) 3-40AConstruction 50& 60AConstruction 6 www.carlingtech.com Percentageof RatedCurrent CLB-Series Pushbutton Thermal Circuit Protector OrderingScheme - - - - CLB 10 3 12 C 3 B B A /10 1 2 3 4 5 6 7 8 9 10 Series Rating Voltage Mounting Bushing Mounting Indicator Button Terminal ButtonMarking Hole Type Nut Plate 1SERIES CLB 10 2RATING NEW 13 03 3amp 05 5amp 07 7amp 10 10amp 13 13amp 18 18amp 25 25amp 35 35amp 50 50amp 13 044amp 06 6amp 08 8amp 12 12amp 15 15amp 20 20amp 30 30amp 40 40amp 60 60amp 3VOLTAGE 3 125-250VAC/32VDC 4MOUNTINGHOLE 1 11 M11 2 12 M12 3 00 SnapIn 4 27 3/8“27UNS 5BUSHING METAL 6 A TypeA 6 B TypeB 8 J TypeJ PLASTIC 5 C TypeC 7 D TypeD 8 E TypeE 9 6MOUNTINGNUT N None 5 Type5 12,15 1 Type1 6 Type6 12 2 Type2 7 Type7 12 3 Type3 8 Type8 4 Type4 NOTE:Type5isclearhexboot.Type8isblackhexboot(availableforbushingsE&Jonly);Type3nutincludesmoldedin“PRESSTORESET”marking. NOTES: 9 7INDICATORPLATE Alldimensionsarein.[mm]. N None Tolerance±.005[.127]unlessotherwisespecified. 1 UsedwithbushingAorBonly. A Embossed 2 UsedwithbushingConly. B SilverPrinting 3 UsedwithbushingDonly. 4 UsedwithbushingE&Jonly. onBlack 5 UsedwithM12mountingholeonly. 6 UsedwithM11mountingholeonly. 7 Usedwithmountinghole00only. 8 Usedwith27mountingholeonly. 9 Allhardwareavailableseparately. Consultfactory. 10 >35ampratingsmust usesolderjointtoconnectwiretonon-screwtypeterminals. Allindicatorplatesaremarked“circuitbreakerpresstoreset”. 11 Terminalsare.040[1.0]thicknessforrating>35,&.315[.8] thicknessisforratings<35amps. 12 AvailablewithtypeEorJbushing only. 13 Availableonlywith10-24 unc.screwterms.(selecttypeF,G,H,Jonly.) 14 Ampratingmustmatchbuttonmarking(ex:“20”willbemarkedonthebuttonofthe 8BUTTON CLB-203-27E3N-B-A/20) B Black R Red W White 15 Thicknessis3.0mm,.118in. 10,11 9TERMINAL A TypeA B TypeB C TypeC D TypeD E TypeE F TypeF G TypeG H TypeH J TypeJ 14 lliinnee 1155 llooaadd 10BUTTONMARKING (IFBLANK,NOMARKING.) ButtonMarkingOrientation: 03 3amp 05 5amp 07 7amp 10 10amp 13 13amp 18 18amp 25 25amp 35 35amp 50 50amp 04 4amp 06 6amp 08 8amp 12 12amp 15 15amp 20 20amp 30 30amp 40 40amp 60 60amp www.carlingtech.com 7 Mostcountrieshaveregulatoryagenciesthatdeterminethesafety CSA andperformancestandardsrequiredforproductsusedinthat TheCSA(CanadianStandardsAssociation)istheclosestincon- country.CarlingTechnologies'circuitbreakersaretestedandhave ceptandnaturetoULofanygroupoutsideoftheUnitedStates. beencertifiedbythemostwidelyrecognizedoftheseagencies Theirstandardsandrequirementsareoftenalmostidenticaltocor- includingUnderwritersLaboratories(UL)intheUnitedStates; respondingULstandards.CSApublishestheirstandardsformost CanadianStandardsAssociation(CSA)inCanada;TUV circuitprotectiondevicesasseparatesectionsofCSAStandard Rheinland/Berlin-Brandenburg(TUV)andVerbandDeutscher C22.2thatinturn,formsapartoftheCanadianElectricalCode. Elektrotechniker(VDE)inGermany. CUL ULRecognized/UL1077Recognized ACULmarkonaproductmeansthatsamplesoftheproducthave ULRecognitioncoverscomponents,whichareincompleteor beenevaluatedtotheapplicableCanadianstandardsandcodes restrictedinperformancecapabilities.Thesecomponentswilllater byUnderwritersLaboratoriesInc. beusedincompleteendproductsorsystemsListedbyUL.These Recognizedcomponentsarenotintendedforseparateinstallation VDEandTUV inthefield,theyareintendedforuseascomponentsofcomplete TherearetwoGermangovernmentapprovedindependentagen- equipmentsubmittedforinvestigationtoUL. cies,VDE(VerbandDeutscherElektrotecchniker),andTUV (TechnisherUberwachungs-Verein).Inthecircuitprotectionfield, CarlingTechnologiesofferscircuitbreakerswhichareclassifiedas outsideoftheU.S.A.andCanada,VDEisthebestknowncertifica- supplementarycircuitprotectorsandareRecognizedundertheUL tionmark.VDEtestingfacilitiesarelocatedinGermany. ComponentsRecognitionProgramasProtectors,Supplementary, ULStandard1077.AUL1077Recognizedsupplementarycircuit TUValsoperformstestingandgrantscertificationinaccordanceto protectormusthaveaListedovercurrentdeviceasa"backup". theIEC/ENspecifications.TUV'sorganizationismadeupofat leastelevengeographicallydispersedcompanies.Atleasttwoare ULListed/UL489Listed locatedintheUnitedStates.ThisaidssomeU.S.manufacturersin ULListingindicatesthatsamplesofthecircuitbreakerasacom- getting"fasttrack"approvaltoaIEC/ENspecifications. pleteproducthavebeentestedbyULtonationallyrecognized safetystandardsandhavebeenfoundtobefreefromreasonably CEMARKING foreseeablerisksoffire,electricshockandrelatedhazards,and TheEuropeanUnion's(EU)approachtocreatesinglemarket thattheproductwasmanufacturedunderUL'sFollow-UpServices accessisbasedonfourprinciples:harmonizeddirectives,harmo- program. nizedstandards,harmonizedconformityassessmentprocedures andCEmarking.TheCEmarkingisaffixedtoproductsindicating CarlingTechnologiesoffersbranchcircuitbreakersthatareUL489 thattheproductconformstorelevantdirectivesandstandards. Listed.Branchcircuitbreakersareclassifiedasafinalovercurrent Variousdirectivesandstandardscontaintherequirementsforthe devicededicatedtoprotectingthebranchcircuitandoutlet(s).They CEmarking.TheCEmarkingisprimarilyformarketcontrolbycus- donotrequireanadditional"backup"overcurrentdevicewiredin tominspectors. seriestoprotectacircuit.Carling'sC,EandF-Seriescircuitbreak- ersofferUL489Listing.Inaddition,theyareUL489AListedforthe BeforeamanufacturercanaffixtheCEmarkingtotheirproduct Telecomindustry. theymustcompletethefollowingsteps: 1. IdentifytheapplicableEUdirective/standard UL1500(MARINE) 2. Performtheconformityassessmentaccordingtotheapplicable UL1500referstoproductsandcomponentsclassifiedasignition- EUdirective/standard protected,andareintendedtobeinstalledandusedinaccordance 3. EstablishaTechnicalFilecontainingtestreports, withapplicablerequirementstotheU.S.CoastGuard,theFire documentation,certificates,etc. ProtectionStandardforPleasureandCommercialMotorCraft, 4. PrepareandsignaEUDeclarationofConformity ANSI/NFPANo.302,andtheAmericanBoatandYachtCouncil, Incorporated. ManyofCarlingTechnologies’circuitprotectionproductsareavail- ablewithCEmarkingindicatingconformancetoLowVoltage Directive73/23/EEC. 8 www.carlingtech.com carlingtech.com Ourextensivewebsiteprovidesin-depth, detailedinformationaboutourproducts andcapabilities.Andwithofficesaround theworld,we’realwaysreadytodobusiness, answerquestionsandhelpourcustomers. Call,faxore-mailanytimetostartworking withacompanythats ’ alwaysON. AdditionalCarlingTechnologiesOffices World-Wide CarlingTechnologies EastRegionSalesOffice,CT CorporateHeadquarters Europe/MiddleEast/Africa ersm@carlingtech.com MidwestRegionSalesOffice,IL CarlingTechnologies,Inc. CarlingTechnologiesLtd. mrsm@carlingtech.com 60JohnsonAvenue Devon,England WestRegionSalesOffice,CA wrsm@carlingtech.com Plainville,CT06062 Int+44(0)1392-364422 GmbH,Germany gmbh@carlingtech.com 860/793-9281 FAX:Int+44(0)1392-364477 SARL,France, FAX:860/793-9231 E-mail:ltdsales@carlingtech.com sarl@carlingtech.com E-mail:info@carlingtech.com Asia-PacificLtd.,Shanghai,China capsh@online.sh.cn www.carlingtech.com CarlingTechnologies Asia-PacificLtd.,Japan japan@carlingtech.com Asia/Pacific Pune,India CarlingTechnologiesAsia-PacificLtd. india@carlingtech.com Kowloon,HongKong Int+852-2737-2277 FAX:Int+852-2736-9332 E-mail:sales@carlingtech.com.hk www.carlingtech.com TCP501_2_07

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the CMB-053-27G6N-B-A/05?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker Hydraulic Magnetic 1Pole 30A 277VAC/80VDC AA1-A0-03-630-1C1-C

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...