CARLING TECHNOLOGIES CX2S00381032A0614
Specifications
Manufacturer
Carling Technologies
Manufacturers Part #
CX2S00381032A0614
Industry Aliases
CX2-S0-03-810-32A-0614
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
CX-S CX-Series eries CIRCUIT BREAKER The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating the arc into an enhanced arc chamber improving the breaker’s overall performance and reliability. The permanent magnets located at the entrance of the arc chamber combined with the upper and lower arc runner increase the magnetic blow out force and aid in motivating the arc off of the contacts and into the arc chamber. An enhanced arc chamber features arc splitter retainers with integrated pressurizing walls, which facilitates heat transfer from the arc thereby providing additional cooling and quick transition into the magnetically induced splitter plates. In turn, the twelve (12) splitter plates attract, segment and cool the arc for full extinction Combined, these innovative features make the CX-Series breaker the best in class, providing stable performance even in the most demanding applications. Resources: Download 3D CAD Files IGS STP Watch Product Video Product Highlights: High DC Voltage Applications: UL 489 & UL 489B Listed Datacom, PDU and UPS Systems TUV Certified IEC/EN 60947-2 Power Supplies and Convertors Temperature stable hydraulic-magnetic Mission Critical Equipment overcurrent sensing technology Renewable Energy Systems Optional relay trip circuit permitting remote Motor Controllers operator system shut down Charging Stations Perfect fit for 380VDC Applications Smart Grids Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com www.carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 | CX-Series Circuit Breaker - Design Features 2 CX-Series DESIGN FEATURES HYDRAULIC/MAGNETIC UPPER ARC RUNNER MAGNETS ARC SPLITTER SENSING COIL Aids in motivating arc off of movable RETAINER contact and into arc chamber with integrated pressurizing walls PATENT PENDING MAGNETIC FLUX LOWER ARC RUNNER LARGE ARC GAP (12) ARC DEIONIZING BOOSTING TERMINAL CONFIGURATION Aids in motivating arc To generate high SPLITTER PLATES Design enhances motivation off of stationary contact arc voltages of arc into arc chamber and into arc chamber Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com CX-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Listed (UL489) configuration and performance capabilities as a Molded Case Circuit Breaker CX SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT MAX CURRENT INTERRUPTING NUMBER CONFIGURATION RATING AMPS CAPACITY (AMPS) OF POLES MAX. RATING FREQUENCY 250 D.C. 15 5,000 1 SERIES 250 / 500 D.C. 15 10,000 2 410 / 205 D.C. 50 10,000 2 Table B: Lists UL Recognized configurations and performance capabilities as a Component Supplementary Protector CX SERIES TABLE B : UL1077 COMPONENT SUPPLEMENTARY PROTECTOR VOLTAGE MAX INTERRUPTING CIRCUIT NUMBER APPLICATION CURRENT CAPACITY CONFIGURATION OF POLES CODE MAX. RATING AMPS (AMPS) FREQUENCY RATING 300 D.C. 1 - 75 5,000 1 TC1, OL0, U3 300 D.C. 76 - 125 3,000 1 TC1, OL0, U3 440 D.C. 1 -30 10,000 2 TC1, OL0, U3 SERIES 440 D.C. 31 - 63 5,000 2 TC1, OL0, U3 600 D.C. 1 - 75 5,000 2 TC1, OL0, U3 600 D.C. 76 - 115 3,000 2 TC1, OL0, U3 1 SWITCH ONLY 600 D.C. 1 - 115 ---- 2 or 3 --- Notes: 1 Requires inclusion of a relay trip voltage coil Table C: Lists UL Listed (UL489B) configuration and performance capabilities as a Molded Case Switch CX SERIES TABLE C : UL489B LISTED PHOTOVATIC MOLDED CASE SWITCH VOLTAGE CIRCUIT CURRENT RATING INTERRUPTING CONSTRUCTION CONFIGURATION MAX RATING FREQUENCY POLES (AMPS) RATING (AMPS) NOTES May have a third pole 1 600 DC 2 50 - 100 600 that is a voltage trip pole SERIES May have a fifth pole 2 600 DC 4 110 - 175 600 that is a voltage trip pole Notes: 1 Two poles in series. 2 Two poles in series in parallel with 2 poles in series. Table D: TUV Certified Configuration to IEC / EN 60947-2. Low Voltage Switch gear and Control gear - Circuit Breakers CX-SERIES TABLE D : TUV IEC/EN 60947-2 LOW VOLTAGE SWITCH GEAR & CONTROL GEAR / CIRCUIT BREAKER INTERRUPTING VOLTAGE CAPACITY CIRCUIT CURRENT RATING CONFIGURATION (AMPS) MAX. ICS / ICU FREQUENCY POLES RATING (AMPS) SERIES 440 DC 2 1-63 4,000 *Manufacturer reserves the right to change product specification without prior notice. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 4 CX-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage 600 VDC Endurance Max 10,000 ON-OFF operations @ Overload 50 operations at 600% of rated 6 per minute; 6000 with rated current for UL489, and at 150% of current & voltage, and 4,000 cycles rated current for UL1077. mechanical. Trip Free Trips on overload even when RESISTANCE PER POLE VALUES RESISTANCE, IMPEDANCE VALUES from from Line to Load Line to LoadTerminals Terminals actuator is forcibly held in the “On” (V (V alues Based on Series alues Based on SeriesT Tri rip Circuit Breaker) p CircuitBreaker) Current Tolerance 1000 position. (amps) (%) CURRENT TOLERANCE Trip Indication The operating handle moves 0.1-5.0 15% (AMPS) (%) 100 positively to the “Off” position when 5.1-20.0 25% 0.10 - 5.0 15 an overload causes the breaker 10 20.1-125 35% to trip. 5.1 - 20.0 25 O H 1 20.1 - 50.0 35 M Environmental S Shock Withstands 100 Gs, 6ms saw tooth 0.1 while carrying rated current per 0.01 MILPRF-55629 and MIL-STD- 202G, Method 213G, Test Condition 0.001 “I”. Instantaneous and ultra short 0.01 0.1 1 10 100-125 100 AMPERE RATING curves tested at 90% of rated current Vibration Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, Physical at rated current per MIL-PRF-55629 Number of Poles 1- 2 poles, + Auxiliary Switch Pole. and MILSTD-202G, Method 204D, Termination 10-32 or M5 Screw Terminals Test Cond. A. Instantaneous & 1/4-20 or M6 Threaded Stud ultrashort curves tested at 90% of Terminals rated current. Termination Barrier Standard with multi-pole constructions Moisture Resistance MIL-PRF-55629 and MIL-STD- Mounting Threaded insert: #6-32 UNC-2B, or 202G, Method 106G, i.e., Ten 24- M3X0.5-6H B ISO (2 per pole) hour cycles at +25°C to +65°C, 80- Actuator Handle, 1 per pole. 98% RH. Internal Circuit Config. Series Trip Salt Spray Method 101, Condition A (90-95% Materials Housing - Glass filled Polyester RH at 5% NaCl Solution, 96 hrs). Handle - Glass filled Polyester Thermal Shock MIL-PRF-55629 and MIL-STD- Line/Load Terminals - Copper Alloy. 202G, Method 107G, Condition A ~150 Grams (~5.3 Ounces). (5-cycles at -55°C to +25°C to Weight ~150 Grams (~5.3 Ounces). +85°C to +25°C). Standard Color Housing - Gray. Operating Temperature -40°C to +85°C. Handle - White, Black, Red, Green, Blue, Yellow, Gray, Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com CX-Series Circuit Breaker - UL489 – Ordering Scheme | 5 C X 1 B 0 14 615 2 2 A 12 G 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting Rating Agency Color & Inserts Approval Switch & Delay Legend 1 SERIES 8 TERMINAL C 2 Screw Terminal, 10-32 3 Stud, 1/4-20 5 Screw Terminal, M5 2 ACTUATOR 6 Stud, M6 X Handle, one per pole 9 ACTUATOR COLOR & LEGEND 3 POLES Actuator Color I-O ON-OFF Dual Legend Color 1 One White A B 1 Black 2 Two Black C D 2 White Red F G 3 White Green H J 4 White 4 CIRCUIT Blue K L 5 White ( ) B Series Trip current Yellow M N 6 Black Gray P Q 7 Black 5 AUXILIARY/ALARM SWITCH Orange R S 8 Black 0 Without Aux Switch 10 MOUNTING INSERTS 6 FREQUENCY & DELAY A 6-32 Thread 11 DC Ultra Short B M3 Thread 12 DC Short 14 DC Medium 11 MAX. APPLICATION RATING 16 DC Long 12 250 VDC 1 13 250/500 VDC 7 CURRENT RATING (AMPERES) 15 205/410 VDC CODE AMPERES 220 0.20 295 0.95 460 6.00 614 14.00 225 0.25 410 1.00 465 6.50 615 15.00 12 AGENCY APPROVAL 230 0.30 512 1.25 470 7.00 616 16.00 A Without Approvals 235 0.35 415 1.50 475 7.50 617 17.00 G UL 489 Listed 1 240 0.40 517 1.75 480 8.00 618 18.00 S UL 489 Listed, TUV to IEC60947-2 245 0.45 420 2.00 485 8.50 620 20.00 250 0.50 522 2.25 490 9.00 622 22.00 Notes: 255 0.55 425 2.50 495 9.50 624 24.00 1 Only Available with 250/500 VDC up to 15 amps. 260 0.60 527 2.75 610 10.00 625 25.00 265 0.65 430 3.00 710 10.50 630 30.00 270 0.70 435 3.50 611 11.00 635 35.00 275 0.75 440 4.00 711 11.50 640 40.00 280 0.80 445 4.50 612 12.00 645 45.00 285 0.85 450 5.00 712 12.50 650 50.00 290 0.90 455 5.50 613 13.00 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 6 CX-Series Circuit Breaker - UL489B – Ordering Scheme C X 2 S 0 03 810 3 2 A 06 14 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Relay Trip Frequency Current Rating Terminal Actuator Mounting Rating Agency Color & Inserts Approval & Delay Legend 4,5 1 SERIES 8 TERMINAL C 3 Stud, 1/4-20 6 Stud, M6 A Stud, 1/4-20, with 10-32 Screw Terminals on Voltage Pole 2 ACTUATOR B Stud, M6, with M5 Screw Terminals on Voltage Pole X Handle, one per pole 9 HANDLE COLOR & LEGEND 1,2 3 POLES Actuator Color I-O ON-OFF Dual Legend Color 2 Two White A B 1 Black 3 Three Black C D 2 White 4 Four Red F G 3 White 5 Five Green H J 4 White Blue K L 5 White Yellow M N 6 Black 4 CIRCUIT Gray P Q 7 Black S Switch Only Orange R S 8 Black 1,2 5 RELAY TRIP VOLTAGE COIL RATING 10 MOUNTING INSERTS 0 Without Relay Trip Voltage Coil A 6-32 Thread B M3 Thread A 12 VDC B 24 VDC C 32 VDC 11 MAX. APPLICATION RATING D 48 VDC 06 600VDC 6 FREQUENCY & DELAY 12 AGENCY APPROVAL 03 DC Switch Only A Without Approvals 14 UL489B Listed 1,3 7 CURRENT RATING (AMPERES) Notes: 1 2 Pole Unit is required for ratings between 50A - 100A. 2-Pole Section 4 Pole Unit is required for ratings between 110A - 175A. 2 A Relay Trip Voltage Coil Pole may be added to either the 2 or 4 Pole construction. 810 50A - 100A The addition of this extra pole dictates a change in the designation for the number of poles in selection 3. 4-Pole Section 3 For Current Ratings between 50A - 100A select current code 810 (100A). 917 110A - 175A For Current Ratings between 101A - 175A select current code 917 (175A). 4 Voltage Pole must have screw terminals. Switch Pole must have stud terminals. 5 On 3 Pole Unit, Voltage Pole to be located at P1 as standard. On 5 Pole Unit, Voltage Pole to be located at P3 as standard. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com CX-Series Circuit Breaker - UL1077 – Ordering Scheme | 7 C X 1 B 0 14 620 2 2 A 10 C 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Aux/Alarm Frequency Current Rating Terminal Actuator Mounting Rating Agency Color & Inserts Approval Switch & Delay Legend 8 1 SERIES 8 TERMINAL C 2 Screw, 10-32 3 Stud, 1/4-20 5 Screw, M5 2 ACTUATOR 6 Stud, M6 X Handle, one per pole 9 ACTUATOR COLOR & LEGEND 7 3 POLES Actuator Color I-O ON-OFF Dual Legend Color 1 One White A B 1 Black 2 Two Black C D 2 White 3 Three Red F G 3 White 10 4 Four Green H J 4 White Blue K L 5 White Yellow M N 6 Black 4 CIRCUIT 1, 9 Gray P Q 7 Black ( ) A Switch Only no coil Orange R S 8 Black ( ) B Series Trip current 1, 2, 3, 9 ( ) G Relay Trip voltage 10 MOUNTING INSERTS A 6-32 Thread 5 AUXILIARY SWITCH B M3 Thread 0 Without Aux Switch 11 MAX. APPLICATION RATING 6 FREQUENCY & DELAY 10 300VDC 03 DC 50/60Hz, Switch Only 4 11 440 VDC without factory installed terminal bus 10 DC Instantaneous 4 14 440VDC with factory installed terminal bus 11 DC Ultra Short 5 06 600VDC 12 DC Short 14 DC Medium 16 DC Long 12 AGENCY APPROVAL A Without Approvals C UL 1077 Recognized 6 7 CURRENT RATING (AMPERES) 9 W UL 1077 Recognized & TUV Certified IEC/ EN 60947-2 CODE AMPERES 220 0.200 415 1.500 490 9.000 630 30.000 Notes: 225 0.250 517 1.750 495 9.500 635 35.000 1 Only available when tied to a protected pole 230 0.300 420 2.000 610 10.000 640 40.000 Requires special P/N consult factory for details 2 Voltage trip circuit coil not rated for continuous duty - use instantaneous delay code 10 235 0.350 522 2.250 710 10.500 650 50.000 3 Contacts Rated for 20A @ 80 VDC 240 0.400 425 2.500 611 11.000 660 60.000 4 440VDC Rating available in two different wiring configurations. 245 0.450 527 2.750 711 11.500 665 65.000 (see next page for more details) 250 0.500 430 3.000 612 12.000 670 70.000 5 600 VDC only available with factory installed terminal bus (see next page for more details) 6 Single pole units available up to 125A, multi pole units limited to 115A Max. 255 0.550 435 3.500 712 12.500 675 75.000 (see next page for more details) 260 0.600 440 4.000 613 13.000 680 80.000 7 3 Pole units must include one Auxiliary switch pole (circuit code A or G) - Requires Special 265 0.650 445 4.500 614 14.000 685 85.000 Part Number. (see next page for more details) 8 Screw Terminals are limited to 50A max. 270 0.700 450 5.000 615 15.000 690 90.000 9 Agency approval code W only available with 440 VDC rating & circuit code B. 275 0.750 455 5.500 616 16.000 695 95.000 10 4 Pole 600 VDC units only available up to 75A Max. (see next page for more details) 280 0.800 460 6.000 617 17.000 810 100.000 285 0.850 465 6.500 618 18.000 911 115.000 290 0.900 470 7.000 620 20.000 912 125.000 295 0.950 475 7.500 622 22.000 410 1.000 480 8.000 624 24.000 512 1.250 485 8.500 625 25.000 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 8 CX-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme Dimensional Specifications: in. [mm] 2.259+0.020 2.259+0.020 0.265 [57.38+0.50] 0.265 [57.38+0.50] [6.73] [6.73] 0.502 0.502 0.755 [12.75] 0.579 0.755 [12.75] [19.18] 0.579 [14.72] [19.18] MAXIMUM [14.72] MAXIMUM 2.259+0.020 0.265 [57.38+0.50] 1.719 [6.73] 0.380 1.719 [43.66] 0.502 0.380 [9.65] [43.66] 0.755 [12.75] [9.65] 0.579 1.843+0.020 [19.18] 1.843+0.020 [14.72] [46.81+0.50] +0.050 MAXIMUM 3.094 [46.81+0.50] +0.050 –0.020 3.094 –0.020 +1.27 78.59 +1.27 –0.50 2.062+0.020 78.59 –0.50 2.062+0.020 [52.37+0.50] 30.0º [52.37+0.50] 30.0º 1.719 0.380 [43.66] 1.052 [9.65] 0.124 1.843+0.020 1.052 [26.72] 0.124 [3.16] [46.81+0.50] [26.72] +0.050 0.626+0.020 [3.16] 2.264+0.020 3.094 –0.020 [15.90+0.50] 0.626+0.020 [57.51+0.50] 2.264+0.020 SHOWN WITH STUD +1.27 [15.90+0.50] 78.59 [57.51+0.50] TERMINAL CONFIGURATION –0.50 SHOWN WITH STUD 2.062+0.020 TERMINAL CONFIGURATION [52.37+0.50] 30.0º 1.017 1.052 0.124 [25.82] [26.72] 1.017 [3.16] [25.82] 0.626+0.020 2.264+0.020 [15.90+0.50] [57.51+0.50] SHOWN WITH STUD TERMINAL CONFIGURATION 1.515 3.672 1.017 [38.48] 1.515 [93.268] [25.82] 3.672 MAXIMUM [38.48] [93.268] 2.259 MAXIMUM [57.38] 2.259 [57.38] 1.515 3.672 [38.48] [93.268] MAXIMUM 2.259 [57.38] & (205/410 VDC) & (205/410 VDC) 2.736 SHOWN WITH SCREW [69.49] TERMINAL CONFIGURATION 0.744 2.736 & SHOWN WITH SCREW [18.90] (WITH SCREW TERMINAL) [69.49] TERMINAL CONFIGURATION 0.744 (205/410 VDC) 2.946 [18.90] (WITH SCREW TERMINAL) 1.520 [74.83] [38.61] 2.946 (WITH STUD TERMINAL) 1.520 0.760 0.156 TYP [74.83] [38.61] 3.276 [19.30] [3.96] (WITH STUD TERMINAL) [83.21] 0.760 0.156 TYP 3.276 [19.30] [3.96] 2.736 (UNFOLDED BARRIER) SHOWN WITH SCREW [83.21] [69.49] TERMINAL CONFIGURATION 0.744 (UNFOLDED BARRIER) [18.90] (WITH SCREW TERMINAL) 1.062 2.946 [26.97] TOLERANCES +.005[.12] 1.520 [74.83] 1.062 [38.61] 2.062 [26.97] (WITH STUD TERMINAL) TOLERANCES +.005[.12] 0.760 0.156 TYP [52.37] 3.276 [19.30] [3.96] 2.062 [83.21] [52.37] 0.750 TYP (UNFOLDED BARRIER) [19.05] 0.625 CX1 0.750 TYP [15.88] CX2 [19.05] 0.625 CX1 1.062 [15.88] [26.97] TOLERANCES +.005[.12] CX2 2.062 [52.37] 0.750 TYP [19.05] 0.625 CX1 [15.88] CX2 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. CLA-8119 Rev: C Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com CX-Series Circuit Breaker - UL489B – Dimensional Specifications | 9 Dimensional Specifications: in. [mm] OPTIONAL VOLTAGE POLE SEE NOTE 1 POLE 1 CX3 POLE 2 CX2 POLE 3 CX3 - 2 POLE SWITCH (CX2)SHOWN WITH OPTIONAL VOLTAGE POLE 50A-100A DEVICE, 600VDC POLE 1 OPTIONAL VOLTAGE POLE SEE NOTE 2 POLE 2 SEE NOTE 3 POLE 3 POLE 4 POLE 5 CX5 - 4 POLE SWITCH (CX4)SHOWN WITH OPTIONAL VOLTAGE POLE 101A-175A DEVICE, 600VDC Notes: 1 All dimensions are in inches [millimeters]. 2 3 pole configuration supplied with voltage coil on pole 1. Optional location pole 3. Consult factory. 3 5 pole configuration supplied with voltage coil in center pole. (Pole 3) 4 Line & Load connections requires bus connection as shown. 2 2 Minimum cross selection .127 in (81.94 mm ) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 10 CX-Series Circuit Breaker - UL1077 – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 600V Rating requires minimum of 2 protected poles Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Sales Representatives, Distributors & Company Profile | 11 Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. CANADA EUROPE USA MIDDLE EAST MEXICO AFRICA ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 @ Email: sales carlingtech.com @ Northern Region Sales Office: nrsm carlingtech.com @ Southeast Region Sales Office: sersm carlingtech.com @ Midwest Region Sales Office: mrsm carlingtech.com @ West Region Sales Office: wrsm carlingtech.com @ Latin America Sales Office: larsm carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Suite 1607, 16/F Tower 2, The Gateway, Harbour City, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 @ Email: sales carlingtech.com.hk @ Shenzhen, China: shenzhen carlingtech.com @ Shanghai, China: shanghai carlingtech.com @ Pune, India: india carlingtech.com @ Kaohsiung, Taiwan: taiwan carlingtech.com @ Yokohama, Japan: japan carlingtech.com | | Europe Middle East Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 @ Email: ltd.sales carlingtech.com @ Germany: gmbh carlingtech.com @ France: sas carlingtech.com www.carlingtech.com REV_04_2018
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the CX2S00381032A0614?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Manufacturers



What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods