CARLING TECHNOLOGIES EA2-B0-24-450-12A-CC

Image of CARLING TECHNOLOGIES EA2-B0-24-450-12A-CC

Description

E-Series Circuit Breaker
EA2-B0-24-450-12A-CC

Part Number

EA2-B0-24-450-12A-CC

Price

Request Quote

Manufacturer

CARLING TECHNOLOGIES

Lead Time

Request Quote

Category

Circuit Protection »  Circuit Breaker

Specifications

Manufacturer

Carling Technologies

Manufacturers Part #

EA2-B0-24-450-12A-CC

Sub-Category

Circuit Breakers

Factory Pack Quantity

1

Datasheet

pdf file

E-Series_Details_%26_COS_010714.pdf

1843 KiB

Extracted Text

E-S E-Series eries CIRCUIT BREAKER The E-Series hydraulic-magnetic circuit breaker is ideally suited for higher current and voltage applications. It is UL listed and CSA certified for branch circuit protection, which does not require a fuse back up. It is also UL recognized and CSA certified as a supplementary protector and as a manual motor controller. Its physical features include front and back mounting, screw and stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for standard wire. The E-series is available with handle actuators and can be configured as .1-125 amps, up to 600VAC or 125VDC, with choice of time delays, actuator colors and 1 to 6 poles configuration. Additionally, a Power Selector device is also available. Product Highlights: Typical Applications: Š Š UL listed and CSA certified High Voltage/High Current Applications Š Certified for circuit branch protection Š Renewable Energy Š Recognized as a supplementary protector Š and as a manual motor controller Military Š Š Optional power selector device Industrial Controls Š Generators Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com www.carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 | 2 E-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage 600VAC 50/60 Hz, 125VDC (See Endurance 10,000 ON-OFF operations @ 6 Table A) per minute; with rated Current and Current Ratings Standard current coils: 0.100, Voltage. 0.250, 0.500, 1.00, 2.50, 5.00, Trip Free All E-Series Circuit Breakers will 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, trip on overload, even when 50.0, 60.0, 70.0 & 100 Amp. Handle is forcibly held in the ON Auxiliary Switch Rating SPDT; 10.1A 250VAC, 1.0A position. 65VDC; 0.5A 80VDC, 0.1A 125VAC Trip Indication The operating Handle moves (with gold contacts). positively to the OFF position Insulation Resistance Minimum of 100 Megohms at 500 when an overload causes the VDC. breaker to trip. Dielectric Strength UL, CSA: 2200 V 50/60 Hz for one Physical minute between all electrically isolated terminals. E-Series Circuit Number of Poles 1 - 6 Breakers comply with the 8mm Mounting A 3” minimum spacing must be spacing and 3750V 50/60 Hz provided between the circuit dielectric requirements from breaker arc venting area on back hazardous voltage to operator connected E-Series circuit accessible surfaces, between breakers and grounded adjacent poles and from main obstructions. E-Series circuit circuits to auxiliary circuits per breakers must be mounted on a Publications EN 60950 and VDE vertical surface. 0805. Connectors, Box Type Front connected E-Series circuit Resistance, Impedance Values from Line to Load Terminal breakers are supplied with box - based on Series Trip Circuit type pressure connectors that Breaker. accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum. Internal Circuit Series and Switch Only, (with or CURRENT TOLERANCE Configuration without auxiliary switch). Shunt (AMPS) (%) with current coils. 0.10 - 5.0 ± 15 Weight Approximately 252 grams/pole 5.1 - 20.0 ± 25 (Approximately 9 ounces/pole) Standard Colors Housing-Black; Actuator - See 20.1 - 50.0 ± 35 Ordering Scheme. Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Pulse Tolerance Curves Method 213, Test Condition “I”. Vibration Withstands 0.060” excursion from Time Delay Curves 10-55 Hz, and 10 Gs 55-500 Hz, at 62, 64 & 66 (100 Amps Max.) rated current per Method 204C, Time Delay Curves Test Condition A. 22, 24 & 26 (100 Amps Max.) Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com E-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case Circuit Breaker. E SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE INTERRUPTING CURRENT RATING HIGH CAPACITY (AMPS) CIRCUIT INTERRUPTING MAX. CONFIGURATION FREQUENCY PHASE CAPACITY WITHOUT BACKUP RATING FULL LOAD AMPS (AMPS) FUSE 80 DC --- 0.10 - 100 5,000 50,000 125 DC --- 0.10 - 100 5,000 10,000 125 DC --- 0.10 - 125 10,000 --- 120 50 / 60 1 0.10 - 125 10,000 --- SERIES 240 50 / 60 1 0.10 - 30 5,000 10,000 240 50 / 60 1 31 - 100 5,000 120 / 240 50 / 60 1 0.10 - 30 5,000 10,000 120 / 240 50 / 60 1 31 - 100 5,000 --- 120 / 240 50 / 60 1 101 - 125 10,000 --- 240 50 / 60 3 0.10 - 100 5,000 --- Table B: Lists UL Recognized & CSA Accepted configurations & performance capabilities as a Component Supplementary Protector. E -SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS VOLTAGE CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES UL/CSA CIRCUIT MAX. FULL LOAD GENERAL CONFIGURATION FREQUENCY PHASE UL CSA WITH BACKUP WITHOUT RATING AMPS PURPOSE AMPS 3 FUSE BACKUP FUSE 125 DC --- 0.02 - 100 --- --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 125 DC --- --- 101 - 120 --- 5,000 TC1,2, OL0, U1 TC1,2, OL0, U1 150 DC --- --- 0.02 - 125 --- 5,000 TC1, OL0, U3 TC1, OL0, U3 160 DC --- 0.02 - 100 --- --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 150 / 300 DC --- 0.02 - 100 --- --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 SERIES & 120 / 240 50 / 60 1 --- 0.02 - 100 --- 5,000 TC1,2, OL0, U1 TC1,2, OL0, U1 SHUNT 240 50 / 60 1 0.02 - 100 --- --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 250 50 / 60 1 0.02 - 100 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 277 50 / 60 1 0.02 - 100 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 480 50 / 60 1 & 3 0.02 - 100 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 1 50 / 60 1 & 3 0.02 - 50 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 480 600 50 / 60 1 & 3 0.02 - 100 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 2 DC --- --- 0.02 - 125 --- 5,000 TC1, OL0, U3 TC1, OL0, U3 600 125 DC --- 0.02 - 120 160 DC --- 0.02 - 100 SWITCH 240 50 / 60 1 0.02 - 100 ONLY 277 50 / 60 1 0.02 - 100 480 50 / 60 1 & 3 0.02 - 100 600 50 / 60 1 & 3 0.02 - 100 Notes: 1 Per pole opposite polarity rating - Delta Configuration. 2 4 Poles connected in series 3 Requires branch circuit backup with a UL Listed Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225A. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 4 E-Series Circuit Breaker - General Specifications Electrical Tables Table C: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a Component Supplementary Protector. E -SERIES TABLE C: COMPONENT SUPPLEMENTARY PROTECTORS WITH VDE VOLTAGE CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES UL/CSA VDE (Icn) CIRCUIT MAX. CONSTRUCTION NOTES WITHOUT WITHOUT CONFIGURATION FREQUENCY PHASE FULL LOAD AMPS WITH BACKUP UL CSA RATING BACKUP BACKUP 1 FUSE FUSE FUSE 125 DC --- 0.1 - 100 --- 5,000 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 1 or 2 Poles 1 - 5 Poles. Up to 4 SERIES & 240 50 / 60 1 & 3 0.1 - 100 --- 5,000 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 Current Poles, 1 Voltage Pole 2 - 5 Poles. Up to 4 SHUNT 415 50 / 60 1 & 3 0.1 - 100 10,000 --- 4,000 TC1,2, OL1, C1 TC1,2, OL1, C1 Current Poles, 1 Voltage Pole --- 125 DC 0.1 - 125 SWITCH ONLY 240 50 / 60 1 & 3 0.1 - 100 415 50 / 60 1 & 3 0.1 - 100 Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225 amps. Table D: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. E SERIES TABLE D : UL1500 (Marine Ignition Protection) VOLTAGE SHORT CIRCUIT CURRENT RATING APPLICATION CODES CAPACITY (AMPS) CIRCUIT MAX. CONFIGURATION FREQUENCY PHASE RATING WITHOUT BACKUP FULL LOAD AMPS UL CSA FUSE 65 DC --- 0.02 - 100 5,000 TC1,2,OL1,U1 TC1,2,OL1,U1 SERIES 125 50 / 60 1 0.02 - 100 1,500 TC1,2,OL1,U1 TC1,2,OL1,U1 250 50 / 60 1 0.02 - 100 1,500 TC1,2,OL1,U1 TC1,2,OL1,U1 Agency Certifications Component Supplementary UL Recognized CSA Accepted UL Standard 1077 Component Recognition Program Protector (Class 3215 30, File as Protectors, Supplementary 047848 0 000) (Guide QVNU2, File E75596) CSA Standard C22.2 No. 235 Component Recognition Program Circuit Breaker Molded Case CSA Certified as Manual Motor Controls (Guide (Class 1432 01, File 093910), NLRV2, File E135367) CSA Standard C22.2 No. 5.1 - M UL Standard 1500 Protectors, Supplementary for TUV Certified EN60934 under License No. Marine Electrical & Fuel Systems R72031056 (Guide PEQZ2, File E75596) Ignition Protection UL Listed VDE Certified EN60934, VDE 0642 under File UL Standard 489 Circuit Breakers, Molded Case No. 10537 (Guide DIVQ, File E129899) Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com E-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme | 5 E A 2 B 0 24 450 1 2 A C B 4 5 8 9 10 11 12 1 2 3 6 7 Terminal Actuator Mounting/ Maximum Agency Series Actuator Poles Circuit Auxiliary Frequency Current Rating Color Barriers Application Switch & Delay Approval Rating 12 1 SERIES 8 TERMINAL E BACK CONNECTED (FRONT MOUNTED ONLY) MAX. RATING 9 1 10-32 Stud (All Terminals) 50 A 9 2 1/4-20 Stud (All Terminals) 120 A 9 2 ACTUATOR A M5 Stud (Line & Load) 50 A 9 A Handle, one per pole B M6 Stud (Line & Load) 100 A FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING 10 1 3 Box Wire Connector (Line & Load) 100 A 3 POLES 11 C Box Wire Connector with Pressure Plate (Line & Load) 100 A 1 One 3 Three 5 Five 4 10-32 Screw (Line & Load) 50 A 2 Two 4 Four 6 Six D M5 Screw (Line & Load) 50 A 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 2 E M5 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 4 CIRCUIT 10 3 6 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A A Switch Only (no coil) E Shunt Trip (voltage) 11 F 10-32 “Bus-Type” Screw (Line), Box Wire Connector B Series Trip (current) F Relay Trip (current) with Pressure Plate (Load) 100 A C Series Trip (voltage) G Relay Trip (voltage) 7 1/4-20 Screw (Line & Load) 100 A D Shunt Trip (current) G M6 Screw (Line & Load) 100 A 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A 4 H M6 “Bus-Type” Screw (Line), M6 Screw (Load) 100 A 5 AUXILIARY SWITCH 10 9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 0 without Auxiliary Switch 6 S.P.S.T. 0.110 Q.C. Terminals 11 J 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector 2 S.P.D.T. 0.110 Q.C. Terminals 7 S.P.S.T. 0.110 Q.C. Terminals with Pressure Plate (Load) 100 A 3 S.P.D.T. 0.139 Solder Lug (Gold Contacts) 4 S.P.D.T. 0.110 Q.C. Terminals 8 S.P.S.T. 0.187 Q.C. Terminals (Gold Contacts) 9 S.P.D.T. 0.187 Q.C. Terminals 13 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF Dual Legend Color 6 FREQUENCY & DELAY White A B 1 Black 3 03 DC 50/60Hz, Switch Only 34 DC, 50/60Hz Medium Black C D 2 White 5 10 DC Instantaneous 36 DC, 50/60Hz Long Red F G 3 White 12 DC Short 62 50/60Hz Short, Hi-Inrush Green H J 4 White 14 DC Medium 64 50/60Hz Medium, Hi-Inrush Blue K L 5 White 16 DC Long 66 50/60Hz Long, Hi-Inrush 5 Yellow M N 6 Black 20 50/60Hz Instantaneous 72 DC, Short,Hi-Inrush 22 50/60Hz Short 74 DC,Medium, Hi-Inrush Gray P Q 7 Black 24 50/60Hz Medium 76 DC, Long, Hi-Inrush Orange R S 8 Black 6 26 50/60Hz Long 92 DC, 50/60Hz Short, Hi-Inrush 6 30 DC, 50/60Hz Instantaneous 94 DC, 50/60Hz Medium, Hi-Inrush 6 32 DC, 50/60Hz Short 96 DC, 50/60Hz Long, Hi-Inrush 10 MOUNTING / BARRIERS BACK CONNECTED (FRONT MOUNTED ONLY) Mounting Inserts 7 7 CURRENT RATING (AMPERES) A 6-32 CODE AMPERES B ISO M3 020 0.020 235 0.350 430 3.000 614 14.000 14 FRONT CONNECTED (BACK MOUNTED ONLY) 025 0.025 240 0.400 435 3.500 615 15.000 Back Mounting Foot Type Front Mounting Inserts (Optional Use) 030 0.030 245 0.450 440 4.000 616 16.000 C Short 6-32 035 0.035 250 0.500 445 4.500 617 17.000 D Short ISO M3 040 0.040 255 0.550 450 5.000 618 18.000 E Long 6-32 045 0.045 260 0.600 455 5.500 620 20.000 F Long ISO M3 050 0.050 265 0.650 460 6.000 622 22.000 055 0.055 270 0.700 465 6.500 624 24.000 060 0.060 275 0.750 470 7.000 625 25.000 15 065 0.065 280 0.800 475 7.500 630 30.000 11 MAXIMUM APPLICATION RATING 16 070 0.070 285 0.850 480 8.000 635 35.000 A 65 VDC, 120 A G 600 VAC, 100 A 16 075 0.075 290 0.900 485 8.500 640 40.000 B 125 VDC, 120 A H 480 VAC, 100 A 16 080 0.080 295 0.950 490 9.000 650 50.000 C 120/240 VAC, 100 A J 415 VAC, 100 A 16 085 0.085 410 1.000 495 9.500 660 60.000 D 240 VAC, 100 A L 160 VDC, 100 A 16 090 0.090 512 1.250 610 10.000 670 70.000 E 277/480 VAC, 100 A T 125 VDC/240 VAC, 100 A 16 090 0.095 415 1.500 710 10.500 680 80.000 F 277 VAC, 100 A W 125 VDC/415 VAC, 100 A 210 0.100 517 1.750 611 11.000 690 90.000 215 0.150 420 2.000 711 11.500 810 100.000 220 0.200 522 2.250 612 12.000 811 110.000 12 AGENCY APPROVAL 225 0.250 425 2.500 712 12.500 812 120.000 B UL 1077 / UL508 Recognized & CSA Accepted 8 230 0.300 527 2.750 613 13.000 912 125.000 D UL 1077 Recognized, CSA Accepted, & VDE Certified 5 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) 4 Auxiliary Switch available on Switch Only and Series Trip units. On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole. Back mounted A06 6 DC, 5 DC A65 65 DC, 55 DC J48 48 AC, 40 AC units require special mounting provisions when auxiliary switch is specified. VDE approval A12 12 DC, 10 DC B25 125 DC, 100 DC J65 65 AC, 55 AC on Auxilary Switch Codes 0,2,3 & 4 only. A18 18 DC, 15 DC J06 6 AC, 5 AC K20 120 AC, 65 AC 5 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay A24 24 DC, 20 DC J12 12 AC, 10 AC L40 240 AC, 130 AC Codes 10 & 20. Series Trip construction with a voltage coil s VDE approved only if tied to A32 32 DC, 25 DC J18 18 AC, 15 AC a protected pole. A48 48 DC, 40 DC J24 24 AC, 20 AC 6 Frequency & Delay Codes 92,94 & 96 are not VDE Certified. 7 Current Coil Ratings 0.100 - 100 ams are VDE Certified. 8 125 A rating (Code 912) available as a Switch Only (Circuit Code A), rated 125 VDC (Code B). Notes: 9 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 (Terminal 1 VDE approval on 1-5 poles only. Standard multi-pole units identical poles except when Code 1). 1/4-20 (Code 2), M5 (Code A), and M6 (Code B) terminals per UL requirement. specifying auxiliary switch - (see Note 4). For mixed ratings, consult factory. 10 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. 2 Switch Only & Series Trip construction available with either front or back connected aluminum wire. terminals. 11 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. Shunt construction available with back connected terminals, (Terminal Codes 1 & 2) only. 12 Terminal Codes A,B,D,E,G & H are not VDE Certified. Circuit Codes B,C & D are VDE approved. 13 VDE approvals require Dual (I-O, ON-OFF) or I-O markings on all handles. 3 Switch Only construction: 30 amps or less select Current Rating Code 630; 31-70 amps, 14 Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting select Current Rating code 670; 71-100 amps, select Current Rating Code 810; 101-125 inserts normally supplied. However, terminal connections must be made prior to mounting. amps Select Current Rating Code 912. Switch Only is VDE approved only if tied to a 15 Application ratings B,D,J,T & W are available with VDE. protected pole. 16 415, 480 & 600 VAC ratings require 3 or 4 pole break 3Ø and 2 pole break 1Ø. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 6 E-Series Circuit Breaker - Handle UL Listed – Ordering Scheme E A 2 B 0 24 1 2 A C C 450 8 9 10 11 12 1 2 3 4 5 6 7 Terminal Actuator Mounting/ Series Actuator Poles Circuit Auxiliary Frequency Maximum Agency Current Rating Color Barriers Switch & Delay Application Approval Rating 7 1 SERIES 8 TERMINAL E BACK CONNECTED (FRONT MOUNTED ONLY) MAX. RATING 8 1 10-32 Stud (All Terminals) 50 A 8 2 1/4-20 Stud (All Terminals) 125 A 2 ACTUATOR A Handle, one per pole FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING 9 3 Box Wire Connector (Line & Load) 100 A 10 C Box Wire Connector with Pressure Plate (Line & Load) 100 A 1 4 10-32 Screw (Line & Load) 50 A 3 POLES 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 1 One 3 Three 5 Five 9 6 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 2 Two 4 Four 6 Six 10 F 10-32 “Bus-Type” Screw (Line), Box Wire Connector with Pressure Plate (Load) 100 A 2 7 1/4-20 Screw (Line & Load) 125 A 4 CIRCUIT 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A B Series Trip (current) 9 3 9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A C Series Trip (voltage) 10 J 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector with Pressure Plate (Load) 100 A 4 5 AUXILIARY SWITCH 0 without Auxiliary Switch 6 S.P.S.T. 0.110 Q.C. Terminals 12 9 ACTUATOR COLOR & LEGEND 2 S.P.D.T. 0.110 Q.C. Terminals 7 S.P.S.T. 0.110 Q.C. Terminals 3 S.P.D.T. 0.139 Solder Lug (Gold Contacts) Actuator Color ON-OFF Dual Legend Color 4 S.P.D.T. 0.110 Q.C. Terminals 8 S.P.S.T. 0.187 Q.C. Terminals White B 1 Black (Gold Contacts) 9 S.P.D.T. 0.187 Q.C. Terminals Black D 2 White Red G 3 White Green J 4 White 6 FREQUENCY & DELAY Blue L 5 White 5 10 DC Instantaneous 62 50/60Hz Short, Hi-Inrush Yellow N 6 Black 12 DC Short 64 50/60Hz Medium, Hi-Inrush Gray Q 7 Black 14 DC Medium 66 50/60Hz Long, Hi-Inrush Orange S 8 Black 16 DC Long 72 DC, Short,Hi-Inrush 5 20 50/60Hz Instantaneous 74 DC,Medium, Hi-Inrush 22 50/60Hz Short 76 DC, Long, Hi-Inrush 24 50/60Hz Medium 10 MOUNTING / BARRIERS 26 50/60Hz Long BACK CONNECTED (FRONT MOUNTED ONLY) Mounting Inserts A 6-32 7 B ISO M3 7 CURRENT RATING (AMPERES) CODE AMPERES 11 FRONT CONNECTED (BACK MOUNTED ONLY) 020 0.020 235 0.350 430 3.000 614 14.000 Back Mounting Foot Type Front Mounting Inserts (Optional Use) 025 0.025 240 0.400 435 3.500 615 15.000 C Short 6-32 030 0.030 245 0.450 440 4.000 616 16.000 D Short ISO M3 035 0.035 250 0.500 445 4.500 617 17.000 E Long 6-32 040 0.040 255 0.550 450 5.000 618 18.000 F Long ISO M3 045 0.045 260 0.600 455 5.500 620 20.000 050 0.050 265 0.650 460 6.000 622 22.000 055 0.055 270 0.700 465 6.500 624 24.000 15 11 MAXIMUM APPLICATION RATING 060 0.060 275 0.750 470 7.000 625 25.000 1 120 VAC 065 0.065 280 0.800 475 7.500 630 30.000 B 125 VDC, 120 A 070 0.070 285 0.850 480 8.000 635 35.000 13 C 120/240 VAC, 100 A 075 0.075 290 0.900 485 8.500 640 40.000 D 240 VAC, 100 A 080 0.080 295 0.950 490 9.000 650 50.000 085 0.085 410 1.000 495 9.500 660 60.000 090 0.090 512 1.250 610 10.000 670 70.000 090 0.095 415 1.500 710 10.500 680 80.000 12 AGENCY APPROVAL 210 0.100 517 1.750 611 11.000 690 90.000 C UL 489 Listed & CSA Certified 215 0.150 420 2.000 711 11.500 810 100.000 F UL 489 Listed, CSA Certified, & VDE Certified 220 0.200 522 2.250 612 12.000 811 110.000 225 0.250 425 2.500 712 12.500 812 120.000 8 Notes: 230 0.300 527 2.750 613 13.000 912 125.000 1 Standard multi-pole units identical poles except when specifying auxiliary switch - 5 (see Note 4). For mixed ratings, consult factory. VDE Certification on 1-5 poles only. OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) 2 Series Trip construction available with either front or back connected terminals. A06 6 DC, 5 DC A65 65 DC, 55 DC J48 48 AC, 40 AC 3 Series Trip construction with a voltage coil is not available as a single pole unit and must be A12 12 DC, 10 DC B25 125 DC, 100 DC J65 65 AC, 55 AC tied to a protected pole. A18 18 DC, 15 DC J06 6 AC, 5 AC K20 120 AC, 65 AC 4 On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole per Figure A. Back mounted units require special mounting provisions when A24 24 DC, 20 DC J12 12 AC, 10 AC L40 240 AC, 130 AC auxiliary switch is specified. VDE Certification on auxilary switch codes 0, 2, 3 & 4 only. A32 32 DC, 25 DC J18 18 AC, 15 AC 5 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay A48 48 DC, 40 DC J24 24 AC, 20 AC Codes 10 & 20. 6 Frequency & Delay Codes 92, 94 & 96 are not VDE Certified. 7 Current Ratings under 0.100 amps are not VDE Certified . 8 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 Stud (Terminal Code 1) or 1/4-20 Stud (Code 2) terminals per UL requirement. 9 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire. 10 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. 11 Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting. 12 VDE Certification requires dual (I-O , ON-OFF) markings on all handles. 13 Not available with VDE Certification. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com E-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams | 7 Circuit & Terminal Diagrams: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 0-50 amps: 10-32 & M5 Studs .625±.062/15.88±1.574 long. 4 51-120 amps: 1/4-20 & M6 Studs .750±.062/19.05±1.574 long. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 8 E-Series Circuit Breaker - Handle (Back Connected) – Dimensional Specifications Dimensional Specifications: in. [mm] Notes: 1 1/4 -20 stud terminal in Series Trip circuit configuration shown. 2 A 3” min spacing must be provided between the circuit breaker arc venting area of back connected E-Series circuit breaker and grounded obstructions. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 5 Circuit breakers must be mounted on vertical surface. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com E-Series Circuit Breaker - Handle (Front Connected) – Dimensional Specifications | 9 Dimensional Specifications: in. [mm] Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Box wire connector terminal in Series Trip circuit configuration shown. 4 Circuit breakers must be mounted on vertical surface. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 10 E-Series Circuit Breaker - Time Delay Values NOTES Delay Curves 10,20,30: Breakers to hold 100% and must trip at 150% of rated current and greater wthin the time limit shown in these curves. Delay Curves 12,14,16,22,24,26,62,64,66,72,74,76: Breakers to hold 100% and must trip at 125% of rated current and greater wthin the time limit shown in these curves. Delay Curves 32,34,36,92,94,96: Breakers to hold 100% and must trip at 135% of rated current and greater wthin the time limit shown in these curves. All curves: Data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading: Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capacity on the above standard delays is 16 times rated current &20 times rated current for high inrush delays based on a 60Hz 1/2 cycle, 8.33 ms pulse. Instantaneous AC DC PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT Short PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT Medium PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT Long PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS E-Series Circuit Breaker - Time Delay Values | 11 AC/DC Instantaneous PERCENT OF RATED CURRENT Short PERCENT OF RATED CURRENT Medium PERCENT OF RATED CURRENT Long PERCENT OF RATED CURRENT Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS TRIP TIME IN SECONDS | 12 Notes Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Sales Representatives, Distributors & Company Profile | 13 Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. CANADA EUROPE USA MIDDLE EAST MEXICO AFRICA ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 @ Email: sales carlingtech.com @ Northern Region Sales Office: nrsm carlingtech.com @ Southeast Region Sales Office: sersm carlingtech.com @ Midwest Region Sales Office: mrsm carlingtech.com @ West Region Sales Office: wrsm carlingtech.com @ Latin America Sales Office: larsm carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Suite 1607, 16/F Tower 2, The Gateway, Harbour City, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 @ Email: sales carlingtech.com.hk @ Shenzhen, China: shenzhen carlingtech.com @ Shanghai, China: shanghai carlingtech.com @ Pune, India: india carlingtech.com @ Kaohsiung, Taiwan: taiwan carlingtech.com @ Yokohama, Japan: japan carlingtech.com | | Europe Middle East Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 @ Email: ltd.sales carlingtech.com @ Germany: gmbh carlingtech.com @ France: sas carlingtech.com www.carlingtech.com REV_03_2017

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the EA2-B0-24-450-12A-CC?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker Hydraulic Magnetic 1Pole 30A 277VAC/80VDC AA1-A0-03-630-1C1-C

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...