Electronics Finder Manufacturers C CARLING TECHNOLOGIES EA2-B2-12-810-2BB-BB
About product Specifications Datasheet FAQ

CARLING TECHNOLOGIES EA2-B2-12-810-2BB-BB

Image of CARLING TECHNOLOGIES EA2-B2-12-810-2BB-BB

Description

Circuit Breaker Hydraulic Magnetic 2Pole 100A 125VDC
EA2-B2-12-810-2BB-BB

Part Number

EA2-B2-12-810-2BB-BB

Price

Request Quote

Manufacturer

CARLING TECHNOLOGIES

Lead Time

Request Quote

Category

Circuit Protection »  Circuit Breaker

Specifications

Manufacturer

Carling Technologies

Manufacturers Part #

EA2-B2-12-810-2BB-BB

Industry Aliases

EA2-B2-12-810-2BB-BB

Sub-Category

Circuit Breakers

Factory Pack Quantity

1

Datasheet

pdf file

E-Series_Details_%26_COS.pdf

2740 KiB

Extracted Text

E-Series Circuit Breaker The E-Series hydraulic/magnetic circuit breaker is ideally suited for higher current and voltage applications. It is UL listed and CSA certified for branch circuit protection, which does not require a fuse back up. It is also UL recognized and CSA certified as a supplementary protector and as a manual motor controller. Its physical features include front and back mounting, screw and stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for standard wire. The E-series is available with handle actuators and can be configured as .1-125 amps, up to 600VAC or 125VDC, with choice of time delays, actuator colors and 1 to 6 poles configuration. Additionally, a Power Selector device is also available. Typical Applications: Š Product Highlights: Ideal for higher current and voltage applications Š Š UL listed and CSA certified Renewable energy systems Š Š Certified for circuit branch protection Military Š Š Recognized as a supplementary protector and as a manual Industrial controls Š motor controller Generators Š Optional Power Selector Device Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062-1177 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: sales@carlingtech.com • www.carlingtech.com | 2 E-Series Circuit Breaker - General Specifications Mechanical Electrical Endurance 6,000 ON-OFF operations @ 6 per Maximum Voltage 600VAC 50/60 Hz, 125VDC (Table A) minute; with rated Current and Voltage. Current Ratings Standard current coils: 0.100, 0.250, Additional 4,000 ON-OFF mechanical. 0.500, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, Trip Free All E-Series Circuit Breakers will trip on 20.0, 25.0, 30.0, 50.0, 60.0, 70.0, 100 & overload, even when Handle is forcibly 125 Amp. held in the ON position. Auxiliary Switch Rating SPDT; 10.1A 250VAC, 1.0A 65VDC; Trip Indication The operating Handle moves positively 0.5A 80VDC, 0.1A 125VAC (with gold to the OFF position when an overload contacts). causes the breaker to trip. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 2200 V 50/60 Hz for one Physical minute between all electrically isolated terminals. E-Series Circuit Breakers Number of Poles 1 - 6 Mounting A 3” minimum spacing must be comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements provided between the circuit breaker from hazardous voltage to operator arc venting area on back connected accessible surfaces, between adjacent E-Series circuit breakers and grounded poles and from main circuits to obstructions. E-Series circuit breakers must be mounted on a vertical surface. auxiliary circuits per Publications EN 60950 and VDE 0805. Connectors, Box Type Front connected E-Series circuit Resistance, Impedance Values from Line to Load Terminal - breakers are supplied with box type based on Series Trip Circuit Breaker. pressure connectors that accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum. Internal Circuit Series and Switch Only, (with or without Configuration auxiliary switch). Shunt with current coils. Weight Approximately 252 grams/pole (Approximately 9 ounces/pole) Standard Colors Housing-Black; Actuator - See Ordering Scheme. Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Shock Withstands 100 Gs, 6ms, sawtooth while Pulse Tolerance Curves carrying rated current per Method 213, Test Condition “I”. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | E-Series Circuit Breaker - General Specifications 3 Agency Certifications UL Recognized CSA Accepted Component Supplementary UL Standard 1077 Component Recognition Program Protector (Class 3215 30, File as Protectors, Supplementary 047848 0 000) (Guide QVNU2, File E75596) CSA Standard C22.2 No. 235 Component Recognition Program CSA Certified Circuit Breaker Molded Case as Manual Motor Controls (Guide (Class 1432 01, File 093910), NLRV2, File E135367) CSA Standard C22.2 No. 5.1 - M UL Standard 1500 Protectors, Supplementary for TUV Certified EN60934 under License No. Marine Electrical & Fuel Systems R72031056 (Guide PEQZ2, File E75596) Ignition Protection EN60934, VDE 0642 under File UL Listed VDE Certified UL Standard 489 Circuit Breakers, Molded Case No. 10537 (Guide DIVQ, File E129899) Electrical Tables Table A: Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case Circuit Breaker. E SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE INTERRUPTING CURRENT RATING HIGH CAPACITY (AMPS) CIRCUIT INTERRUPTING MAX. CONFIGURATION CAPACITY FREQUENCY PHASE WITHOUT BACKUP RATING FULL LOAD AMPS (AMPS) FUSE 80 DC --- 0.10 - 100 5,000 50,000 125 DC --- 0.10 - 100 5,000 10,000 125 DC --- 101 - 125 10,000 --- 120 50 / 60 1 101 - 125 10,000 --- SERIES 240 50 / 60 10.10 - 30 5,000 10,000 240 50 / 60 1 31 - 100 5,000 120 / 240 50 / 60 10.10 - 30 5,000 10,000 120 / 240 50 / 60 1 31 - 100 5,000 --- 120 / 240 50 / 60 1 101 - 125 10,000 --- 240 50 / 60 30.10 - 100 5,000 --- Table B: Lists UL Recognized & CSA Accepted configurations & performance capabilities as a Component Supplementary Protector. E -SERIES TABLE B: COMPONENT SUPPLEMENTARY PROTECTORS VOLTAGE CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES UL/CSA CIRCUIT MAX. FULL LOAD GENERAL CONFIGURATION FREQUENCY PHASE UL CSA WITH BACKUP WITHOUT RATING AMPS PURPOSE AMPS 3 FUSE BACKUP FUSE 125 DC --- 0.02 - 100 --- --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 125 DC --- --- 101 - 120 --- 5,000 TC1,2, OL0, U1 TC1,2, OL0, U1 150 DC --- --- 0.02 - 125 --- 5,000 TC1, OL0, U3 TC1, OL0, U3 160 DC --- 0.02 - 100 --- --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 150 / 300 DC --- 0.02 - 100 --- --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 SERIES & 120 / 240 50 / 60 1 --- 0.02 - 100 --- 5,000 TC1,2, OL0, U1 TC1,2, OL0, U1 SHUNT 240 50 / 60 1 0.02 - 100 --- --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 250 50 / 60 1 0.02 - 100 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 --- 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 277 50 / 60 1 0.02 - 100 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 480 50 / 60 1 & 3 0.02 - 100 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 1 50 / 60 1 & 3 0.02 - 50 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 480 600 50 / 60 1 & 3 0.02 - 100 --- 10,000 --- TC1,2, OL1, C1 TC1,2, OL1, C1 2 DC --- --- 0.02 - 125 --- 5,000 TC1, OL0, U3 TC1, OL0, U3 600 125 DC --- 0.02 - 120 Table B Notes: 160 DC --- 0.02 - 100 1 Per pole opposite polarity rating - Delta Configuration. SWITCH 240 50 / 60 1 0.02 - 100 2 4 Poles connected in series ONLY 277 50 / 60 1 0.02 - 100 3 Requires branch circuit backup with a UL Listed Type K5 or RK5 fuse 480 50 / 60 1 & 3 0.02 - 100 rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225A. 600 50 / 60 1 & 3 0.02 - 100 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 4 E-Series Circuit Breaker - General Specifications Electrical Tables Table C: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a Component Supplementary Protector. E -SERIES TABLE C: COMPONENT SUPPLEMENTARY PROTECTORS WITH VDE VOLTAGE CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES UL/CSA VDE (Icn) CIRCUIT MAX. CONSTRUCTION NOTES CONFIGURATION WITHOUT WITHOUT FREQUENCY PHASE FULL LOAD AMPS UL CSA WITH BACKUP RATING BACKUP BACKUP 1 FUSE FUSE FUSE 125 DC --- 0.1 - 100 --- 5,000 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 1 or 2 Poles 1 - 5 Poles. Up to 4 SERIES & 240 50 / 60 1 & 30.1 - 100 --- 5,000 5,000 TC1,2, OL1, U1 TC1,2, OL1, U1 Current Poles, 1 Voltage Pole 2 - 5 Poles. Up to 4 SHUNT 415 50 / 60 1 & 30.1 - 100 10,000 --- 4,000 TC1,2, OL1, C1 TC1,2, OL1, C1 Current Poles, 1 Voltage Pole --- 125DC 0.1 - 125 SWITCH ONLY 240 50 / 60 1 & 30.1 - 100 415 50 / 60 1 & 30.1 - 100 Table C Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225 amps. Table D: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. E SERIES TABLE D : UL1500 (Marine Ignition Protection) VOLTAGE SHORT CIRCUIT CURRENT RATING APPLICATION CODES CAPACITY (AMPS) CIRCUIT MAX. CONFIGURATION FREQUENCY PHASE RATING WITHOUT BACKUP FULL LOAD AMPS UL CSA FUSE 65 DC --- 0.02 - 1005,000 TC1,2,OL1,U1 TC1,2,OL1,U1 SERIES 125 50 / 60 1 0.02 - 1001,500 TC1,2,OL1,U1 TC1,2,OL1,U1 250 50 / 60 1 0.02 - 1001,500 TC1,2,OL1,U1 TC1,2,OL1,U1 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | E-Series Handle UL Recognized – Ordering Scheme 5 E A 2 – B 0 – 24 – 450 – 1 2 A – C B 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Auxiliary Frequency Current Rating Terminal Actuator Mounting/ Maximum Agency Color Barriers Application Approval Switch & Delay Rating 12 1 SERIES 8 TERMINAL E BACK CONNECTED (FRONT MOUNTED ONLY) MAX. RATING 9 1 10-32 Stud (All Terminals) 50 A 9 2 1/4-20 Stud (All Terminals) 120 A 2 ACTUATOR 9 A M5 Stud (Line & Load) 50 A A Handle, one per pole 9 B M6 Stud (Line & Load) 100 A FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING 10 3 Box Wire Connector (Line & Load) 100 A 1 11 3 POLES C Box Wire Connector w/ Pressure Plate (Line & Load) 100 A 1 One 3 Three 5 Five 4 10-32 Screw (Line & Load) 50 A 2 Two 4 Four 6 Six D M5 Screw (Line & Load) 50 A 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A E M5 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 2 4 CIRCUIT 10 6 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 3 ( ) ( ) A Switch Only no coil E Shunt Trip voltage 11 F 10-32 “Bus-Type” Screw (Line), Box Wire Connector ( ) ( ) B Series Trip current F Relay Trip current w/ Pressure Plate (Load) 100 A ( ) ( ) C Series Trip voltage G Relay Trip voltage 7 1/4-20 Screw (Line & Load) 100 A ( ) D Shunt Trip current G M6 Screw (Line & Load) 100 A 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A H M6 “Bus-Type” Screw (Line), M6 Screw (Load) 100 A 4 5 AUXILIARY SWITCH 10 9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 0 without Auxiliary Switch 6 S.P.D.T. 0.110 Q.C. Terminals 11 J 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector 2 S.P.D.T. 0.110 Q.C. Terminals 7 S.P.D.T. 0.110 Q.C. Terminals w/ Pressure Plate (Load) 100 A 3 S.P.D.T. 0.139 Solder Lug (Gold Contacts) 4 S.P.D.T. 0.110 Q.C. Terminals 8 S.P.D.T. 0.187 Q.C. Terminals (Gold Contacts) 9 S.P.D.T. 0.187 Q.C. Terminals 13 9 ACTUATOR COLOR & LEGEND Acuator Color I-O ON-OFF Dual Legend Color White A B 1 Black 6 FREQUENCY & DELAY 34 DC, 50/60Hz Medium Black C D 2 White 3 03 DC 50/60Hz, Switch Only 36 DC, 50/60Hz Long Red F G 3 White 5 10 DC Instantaneous 62 50/60Hz Short, Hi-Inrush Green H J 4 White 12 DC Short 64 50/60Hz Medium, Hi-Inrush Blue K L 5 White 14 DC Medium 66 50/60Hz Long, Hi-Inrush Yellow M N 6 Black 16 DC Long 72 DC, Short,Hi-Inrush Gray P Q 7 Black 5 20 50/60Hz Instantaneous 74 DC,Medium, Hi-Inrush Orange R S 8 Black 22 50/60Hz Short 76 DC, Long, Hi-Inrush 6 24 50/60Hz Medium 92 DC, 50/60Hz Short, Hi-Inrush 6 26 50/60Hz Long 94 DC, 50/60Hz Medium, 10 MOUNTING/BARRIERS 30 DC, 50/60Hz Instantaneous Hi-Inrush BACK CONNECTED (FRONT MOUNTED ONLY) 6 32 DC, 50/60Hz Short 96 DC, 50/60Hz Long, Hi-Inrush Mounting Inserts A 6-32 B ISO M3 7 7 CURRENT RATING (AMPERES) 14 FRONT CONNECTED (BACK MOUNTED ONLY) CODE AMPERES Back Mounting Foot Type Front Mounting Inserts (Optional Use) 020 0.020 235 0.350 430 3.000 614 14.000 C Short 6-32 025 0.025 240 0.400 435 3.500 615 15.000 D Short ISO M3 030 0.030 245 0.450 440 4.000 616 16.000 E Long 6-32 035 0.035 250 0.500 445 4.500 617 17.000 F Long ISO M3 040 0.040 255 0.550 450 5.000 618 18.000 045 0.045 260 0.600 455 5.500 620 20.000 15 11 MAXIMUM APPLICATION RATING 050 0.050 265 0.650 460 6.000 622 22.000 16 055 0.055 270 0.700 465 6.500 624 24.000 A 65 VDC, 120 A G 600 VAC, 100 A 16 060 0.060 275 0.750 470 7.000 625 25.000 B 125 VDC, 120 A H 480 VAC, 100 A 16 065 0.065 280 0.800 475 7.500 630 30.000 C 120/240 VAC, 100 A J 415 VAC, 100 A 16 070 0.070 285 0.850 480 8.000 635 35.000 D 240 VAC, 100 A L 160 VDC, 100 A 16 075 0.075 290 0.900 485 8.500 640 40.000 E 277/480 VAC, 100 A T 125 VDC/240 VAC, 100 A 16 080 0.080 295 0.950 490 9.000 650 50.000 F 277 VAC, 100 A W 125 VDC/415 VAC, 100 A 085 0.085 410 1.000 495 9.500 660 60.000 090 0.090 512 1.250 610 10.000 670 70.000 090 0.095 415 1.500 710 10.500 680 80.000 12 AGENCY APPROVAL 210 0.100 517 1.750 611 11.000 690 90.000 UL 1077 / UL508 Recognized & CSA Accepted B 215 0.150 420 2.000 711 11.500 810 100.000 UL 1077 Recognized, CSA Accepted, & VDE Certified D 220 0.200 522 2.250 612 12.000 811 110.000 4 Auxiliary Switch available on Switch Only and Series Trip units. On multi-pole units, only 225 0.250 425 2.500 712 12.500 812 120.000 8 one auxiliary switch is normally supplied mounted in the extreme right pole. Back mounted 230 0.300 527 2.750 613 13.000 912 125.000 units require special mounting provisions when auxiliary switch is specified. VDE approval 5 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) on Auxilary Switch Codes 0,2,3 & 4 only. A06 6 DC, 5 DC A65 65 DC, 55 DC J48 48 AC, 40 AC 5 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay A12 12 DC, 10 DC B25 125 DC, 100 DC J65 65 AC, 55 AC Codes 10 & 20. Series Trip construction with a voltage coil s VDE approved only if tied to A18 18 DC, 15 DC J06 6 AC, 5 AC K20 120 AC, 65 AC a protected pole. A24 24 DC, 20 DC J12 12 AC, 10 AC L40 240 AC, 130 AC 6 Frequency & Delay Codes 92,94 & 96 are not VDE Certified. A32 32 DC, 25 DC J18 18 AC, 15 AC 7 Current Coil Ratings 0.100 - 100 ams are VDE Certified. 8 125 A rating (Code 912) available as a Switch Only (Circuit Code A), rated 125 VDC (Code B). A48 48 DC, 40 DC J24 24 AC, 20 AC 9 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 (Terminal Notes: Code 1). 1/4-20 (Code 2), M5 (Code A), and M6 (Code B) terminals per UL requirement. 10 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. 1 VDE approval on 1-5 poles only. Standard multi-pole units identical poles except when aluminum wire. specifying auxiliary switch - (see Note 4). For mixed ratings, consult factory. 11 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. 2 Switch Only & Series Trip construction available w/either front or back connected terminals. 12 Terminal Codes A,B,D,E,G & H are not VDE Certified. Shunt construction available w/back connected terminals, (Terminal Codes 1 & 2) only. 13 VDE approvals require Dual (I-O, ON-OFF) or I-O markings on all handles. Circuit Codes B,C & D are VDE approved. 14 Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting 3 Switch Only construction: 30 amps or less select Current Rating Code 630; 31-70 amps, inserts normally supplied. However, terminal connections must be made prior to mounting. select Current Rating code 670; 71-100 amps, select Current Rating Code 810; 101-125 15 Application ratings B,D,J,T & W are available with VDE. amps Select Current Rating Code 912. Switch Only is VDE approved only if tied to a 16 415, 480 & 600 VAC ratings require 3 or 4 pole break 3Ø and 2 pole break 1Ø. protected pole. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 6 E-Series Handle UL Listed – Ordering Scheme E A 2 – B 0 – 24 – 450 – 1 2 A – C C 1 2 3 4 5 6 7 8 9 10 11 12 Series Actuator Poles Circuit Auxiliary Frequency Current Rating Terminal Actuator Mounting/ Maximum Agency Color Barriers Application Approval Switch & Delay Rating 7 1 SERIES 8 TERMINAL E BACK CONNECTED (FRONT MOUNTED ONLY) MAX. RATING 8 1 10-32 Stud (All Terminals) 50 A 8 2 1/4-20 Stud (All Terminals) 125 A 2 ACTUATOR FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING A Handle, one per pole 9 3 Box Wire Connector (Line & Load) 100 A 10 C Box Wire Connector w/ Pressure Plate (Line & Load) 100 A 4 10-32 Screw (Line & Load) 50 A 1 3 POLES 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 9 1 One 3 Three 5 Five 6 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 10 2 Two 4 Four 6 Six F 10-32 “Bus-Type” Screw (Line), Box Wire Connector w/ Pressure Plate (Load) 100 A 7 1/4-20 Screw (Line & Load) 125 A 2 4 CIRCUIT 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A 3 ( ) ( ) B Series Trip current C Series Trip voltage 9 9 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 10 J 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector w/ Pressure Plate (Load) 100 A 4 5 AUXILIARY SWITCH 0 without Auxiliary Switch 6 S.P.D.T. 0.110 Q.C. Terminals 12 2 S.P.D.T. 0.110 Q.C. Terminals 7 S.P.D.T. 0.110 Q.C. Terminals 9 ACTUATOR COLOR & LEGEND 3 S.P.D.T. 0.139 Solder Lug (Gold Contacts) Acuator Color Legend Color ON-OFF Dual 4 S.P.D.T. 0.110 Q.C. Terminals 8 S.P.D.T. 0.187 Q.C. Terminals White Black B 1 (Gold Contacts) 9 S.P.D.T. 0.187 Q.C. Terminals Black White D 2 Red White G 3 Green White J 4 6 FREQUENCY & DELAY 36 DC, 50/60Hz Long Blue White L 5 5 10 DC Instantaneous 62 50/60Hz Short, Hi-Inrush Yellow Black N 6 12 DC Short 64 50/60Hz Medium, Hi-Inrush Gray Black Q 7 14 DC Medium 66 50/60Hz Long, Hi-Inrush Orange Black S 8 16 DC Long 72 DC, Short,Hi-Inrush 5 20 50/60Hz Instantaneous 74 DC,Medium, Hi-Inrush 22 50/60Hz Short 76 DC, Long, Hi-Inrush 10 MOUNTING/BARRIERS 6 24 50/60Hz Medium 92 DC, 50/60Hz Short, Hi-Inrush BACK CONNECTED (FRONT MOUNTED ONLY) 6 26 50/60Hz Long 94 DC, 50/60Hz Medium, Mounting Inserts 30 DC, 50/60Hz Instantaneous Hi-Inrush A 6-32 6 32 DC, 50/60Hz Short 96 DC, 50/60Hz Long, Hi-Inrush B ISO M3 34 DC, 50/60Hz Medium 11 FRONT CONNECTED (BACK MOUNTED ONLY) Back Mounting Foot Type Front Mounting Inserts (Optional Use) C Short 6-32 7 7 CURRENT RATING (AMPERES) D Short ISO M3 CODE AMPERES E Long 6-32 F Long ISO M3 020 0.020 235 0.350 430 3.000 614 14.000 025 0.025 240 0.400 435 3.500 615 15.000 030 0.030 245 0.450 440 4.000 616 16.000 035 0.035 250 0.500 445 4.500 617 17.000 11 MAXIMUM APPLICATION RATING 040 0.040 255 0.550 450 5.000 618 18.000 1 120 VAC 045 0.045 260 0.600 455 5.500 620 20.000 B 125 VDC, 120 A 13 050 0.050 265 0.650 460 6.000 622 22.000 C 120/240 VAC, 100 A 055 0.055 270 0.700 465 6.500 624 24.000 D 240 VAC, 100 A 060 0.060 275 0.750 470 7.000 625 25.000 065 0.065 280 0.800 475 7.500 630 30.000 070 0.070 285 0.850 480 8.000 635 35.000 12 AGENCY APPROVAL 075 0.075 290 0.900 485 8.500 640 40.000 C UL 489 Listed & CSA Certified 080 0.080 295 0.950 490 9.000 650 50.000 F UL 489 Listed, CSA Certified, & VDE Certified 085 0.085 410 1.000 495 9.500 660 60.000 090 0.090 512 1.250 610 10.000 670 70.000 090 0.095 415 1.500 710 10.500 680 80.000 Notes: 210 0.100 517 1.750 611 11.000 690 90.000 1 Standard multi-pole units identical poles except when specifying auxiliary switch - 215 0.150 420 2.000 711 11.500 810 100.000 (see Note 4). For mixed ratings, consult factory. VDE Certification on 1-5 poles only. 220 0.200 522 2.250 612 12.000 811 110.000 2 Series Trip construction available w/either front or back connected terminals. 3 Series Trip construction with a voltage coil is not available as a single pole unit and must be 225 0.250 425 2.500 712 12.500 812 120.000 8 tied to a protected pole. 230 0.300 527 2.750 613 13.000 912 125.000 4 On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme 5 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) right pole per Figure A. Back mounted units require special mounting provisions when A06 6 DC, 5 DC A65 65 DC, 55 DC J48 48 AC, 40 AC auxiliary switch is specified. VDE Certification on auxilary switch codes 0, 2, 3 & 4 only. A12 12 DC, 10 DC B25 125 DC, 100 DC J65 65 AC, 55 AC 5 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay A18 18 DC, 15 DC J06 6 AC, 5 AC K20 120 AC, 65 AC Codes 10 & 20. 6 Frequency & Delay Codes 92, 94 & 96 are not VDE Certified. A24 24 DC, 20 DC J12 12 AC, 10 AC L40 240 AC, 130 AC 7 Current Ratings under 0.100 amps are not VDE Certified . A32 32 DC, 25 DC J18 18 AC, 15 AC 8 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 Stud A48 48 DC, 40 DC J24 24 AC, 20 AC (Terminal Code 1) or 1/4-20 Stud (Code 2) terminals per UL requirement. 9 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire. 10 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. 11 Back Mounted breakers can also be front mounted by utilizing the proper front panel mouning inserts normally supplied. However, terminal connections must be made prior to mounting. 12 VDE Certification requires dual (I-O , ON-OFF) markings on all handles. 13 Not available with VDE Certification. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | E-Series Handle – Circuit & Terminal Diagrams 7 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 0-50 amps: 10-32 & M5 Studs .625±.062/15.88±1.574 long. 4 51-120 amps: 1/4-20 & M6 Studs .750±.062/19.05±1.574 long. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | 8 E-Series Handle (Back Connected) – Form & Fit Drawings Notes: 1 1/4 -20 stud terminal in Series Trip circuit configuration shown. 2 A 3” min spacing must be provided between the circuit breaker arc venting area of back connected E-Series circuit breaker and grounded obstructions. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 5 Circuit breakers must be mounted on vertical surface. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | E-Series Handle (Front Connected) – Form & Fit Drawings 9 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Box wire connector terminal in Series Trip circuit configuration shown. 4 Circuit breakers must be mounted on vertical surface. REV_CB_E_0812 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the EA2-B2-12-810-2BB-BB?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker Hydraulic Magnetic 1Pole 30A 277VAC/80VDC AA1-A0-03-630-1C1-C

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...

product

Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...