CARLING TECHNOLOGIES PCB-B3-26-650-12E-E11
Specifications
Manufacturer
Carling Technologies
Manufacturers Part #
PCB-B3-26-650-12E-E11
Industry Aliases
PCB-B3-26-650-12E-E11
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
PC-S PC-Series eries GFCI/ELCI & PANEL SEAL The PC-Series, AC Residual Current Circuit Breaker with Overcurrent Protection (RCBO), combines the ground fault protection of a GFCI with the familiar overcurrent tripping characteristics of a normal circuit breaker. It detects lower level ground faults that do not trip ordinary circuit breakers, but could lead to shock hazards and fires in installations near water. Innovative features include status LED indicators distinguishing if a breaker is closed with line voltage present, or has opened due to leakage current, or has opened due to over current, or is closed with no line voltage present. Resources: Download 3D CAD Files IGS STP Product Highlights: Typical Applications: Meets latest UL 943 standards Generators GFCI self-test auto-monitoring & end-of-life Water Heaters indication Battery Chargers Integrated push-to-reset button Marine Overload, short circuit and ground fault protection AC main ground fault protection for in a single package a boat’s entire AC electrical system Status LED indicators Single circuit solution for AC branch ground fault protection Optional panel seal Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com www.carlingtech.com Application Support: team2@carlingtech.com Phone: 860.793.9281 Fax: 860.793.9231 | 2 PC-Series Circuit Breaker - General Specifications PC-Series Switch DESIGN FEATURES MOUNTING PLATE OPTIONAL SEAL LEDs Available in stainless steal or zinc IP66/67 panel seals provide ideal Two separate lights that indicate chromate plated carbon steel protection against salt spray, power, ground fault leakage and ozone, dust, water and most acids end-of-life *Manufacturer reserves the right to change product specification without prior notice. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com PC-Series Circuit Breaker - General Specifications | 3 Electrical Tables Table A: UL Listed & CSA Certified configurations as a Ground Fault Circuit Interruptor PC-SERIES TABLE A: UL Listed / CSA 22.2 No. 144.1 Configurations as a Ground Fault Circuit Interruptor Voltage Current Short Circuit Ground Fault Circuit Rating Capacity Trip Level Notes Frequency Configuration Max Rating Phase (Amps) (Amps) (Milliamps) (Hertz) 120 60 1 1 - 50 5000 6 1 or 2 Poles. One pole of a two pole unit must be Neutral Series 2 or 3 Poles. One pole of a three pole unit must be Neutral 120 / 240 60 1 1 - 50 5000 6 Table B: UL Recognized as an Earth Leakage Circuit Interruptor - 120 and 120/240V PC-SERIES TABLE B: UL Recognized Configurations as an Earth Leakage Circuit Interruptor Voltage Current Short Circuit Ground Fault Circuit Rating Capacity Trip Level Notes Frequency Configuration Max Rating Phase (Amps) (Amps) (Milliamps) (Hertz) 120 50 / 60 1 1 - 50 5000 30 1 or 2 Poles. One pole of a two pole unit must be Neutral Series 2 or 3 Poles. One pole of a three pole unit must be Neutral 120 / 240 50 / 60 1 1 - 50 5000 30 120 50 / 60 1 1 - 50 3000 30 1 or 2 Poles. One pole of a two pole unit must be Neutral Series Ignition Protection 2 or 3 Poles. One pole of a three pole unit must be Neutral 120 / 240 50 / 60 1 1 - 50 5000 30 Table C: UL Recognized as an Earth Leakage Circuit Interruptor - 240V PC-SERIES TABLE C: UL Recognized Configurations as an Earth Leakage Circuit Interruptor - 240V Voltage Current Short Circuit Ground Fault Circuit Rating Capacity Trip Level Notes Frequency Configuration Max Rating Phase (Amps) (Amps) (Milliamps) (Hertz) 2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 11 Series 240 50 / 60 1 1 - 30 5000 30 Series Ignition 2 or 3 Poles. One pole of a three pole unit must be Neutral. Suffix 12 240 50 / 60 1 1 - 50 5000 30 Protection Impedance (Across Circuit breaker only) RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Braker) 1000 100 CURRENT TOLERANCE (AMPS) (%) 10 0.10 - 5.0 ± 15 O 5.10 - 20.0 ± 25 H 1 20.10 - 50.0 ± 35 M S 0.1 0.01 0.001 0.01 0.1 1 10 100 AMPERE RATING Agency Certifications UL Standard 489 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) UL Standard 1077 Supplementary Protectors UL Standard 943 & CSA 22.2 No. 144.1 Class A Ground Fault Circuit Interrupters UL Standard 1053 Ground Fault Sensing and Relaying Equipment UL Standard 1500 Ignition Protection Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 4 PC-Series Circuit Breaker - General Specifications Electrical Physical Current Ratings 50 Amps maximum Number of Poles 1-pole (1 Circuit Breaker + 1 GFCI Voltage Rating 120 VAC, 120/240 VAC Sensor Module), 120V. 2-pole Dielectric Strength 1480 VAC, 60Hz for 1 minute (2 Circuit Breakers + 1 GFCI Sensor between all electrically isolated Module), 120/240V or 120V with terminals Switched Neutral. 3-pole (3 Circuit Insulation Resistance Minimum of 100 Megohms at Breakers + 1 GFCI Sensor Module), 500VDC 120/240V with Switched Neutral. Leakage Current Trip Level 5±1 mA Termination Circuit Breaker Line Side: #10-32 Leakage Current Trip Time ≤ 25 ms complies with UL 943 GFCI Sensor Module Load Side: EMI UL 943 / IEC 61000-4-6, 0.5V #10-32. Neutral pigtail provided with 150KHz ~ 230 MHz non-switched neutral units. Operating Frequency 50/60 Hz Mounting Front Panel, #6-32 or M3 threaded Reverse Polarity A reversed Line / Load connection inserts. to the circuit breaker shall not cause Actuator Handle, Flat Rocker, Curved Rocker damage to the device (with or without rocker guard), Grounded Neutral When neutral is grounded on load Push-to-Reset Rocker side of circuit Internal Configuration Circuit Breaker, Series Trip Overload 50 operations @ 600% of rated Switch only (without over-current current on Breakers protection) Switched Neutral 2nd Pole on 120V and 3rd Pole on Weight 1-pole: approximately 300 grams 120/240V, Optional (10.6 ounces) Manual Test To be performed at least every 2-pole: approximately 375 grams month by pressing the test button (13.2 ounces) on the GFCI to verify the device’s 3-pole: approximately 500 grams ability to respond and trip when (17.6 ounces) subjected to simulated leakage. Standard Colors Housing – Black, Test Button – Current imbalance is sufficient White, Text – White to cause tripping at 85% of rated voltage. Line Power at L1 is required. Environmental GFCI Auto-Monitoring Performed automatically without Designed and tested in accordance with requirements of opening circuit breaker contacts specification MIL-PRF- 55629 and MIL-STD-202G as follows: or compromising ability to respond Shock Withstands 100 G, 6ms, sawtooth to ground or neutral faults. at rated current per Method 213, Automatic Self-Test performed Test Condition “I”. automatically every time power is Thermal Shock Method 107D, Condition A (5-cycle supplied within 5 seconds. at -55ºC to +25ºC to +85ºC to +25ºC) Automatic Self-Test Frequency: 3 Vibration Withstands 0.06” excursion from seconds. Line Power at L1 is 10-55 Hz, and 10 G 55-500 Hz, at required. Feedback when auto- rated current per Method 204C, Test monitoring Self-Test fails: Circuit Condition A. Instantaneous & breaker trips and cannot be reset ultrashort curves tested at 90% of and a visual indication is displayed rated current. (See Next Page). Moisture Resistance 93% RH at 30°C for 168 Hours. GFCI Heartbeat Indicator Successful Self Tests are followed Operating Temperature -35°C to +66°C by a flash of light per Next Page Corrosion UL-943-6.21, 3 weeks GFCI End of Life Circuit breaker trips and cannot be Humidity: 30±2°C, 70±2% relative reset. A visual indication is humidity displayed via the LED’s located on Mixed Flowing Gases: the front of the device (See Next 100 ppb H S, 2 Page). Line Power at L1 is required. 20 ppb CI , 2 Mechanical 200±50 ppb NO 2 Endurance 10,000 “On-Off” Operations at 6 per minute; 6000 with Rated Current & Voltage (3000 test button and 3000 manual operations) and 4000 on/off operations with no load. Trip Free Trips on short circuit, overload or leakage to ground, even when actuator is forcibly held in the “On” position *Manufacturer reserves the right to change product specification without prior notice. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | PC-Series Circuit Breaker - General Specifications 5 GFCI LED Indication Condition Breaker LED Output Power with Open Circuit Open None Circuit Manually Opened Open None Power with Closed Circuit Closed Green (solid) Ground Fault Leakage Trips Open Red (solid) Grounded Neutral Trips Open Red (solid) Passed Automatic, Self-Test Closed Red (flash lasting 2 ms, every 3 seconds) Failed Automatic, Self-Test Trips Open Red (continuous flashing, every 0.10 seconds) Manual GFCI Monthly Test Trips Open Red (solid) Over Current Trips Open None End of Life Trips Open Red (continuous flashing, every 0.10 seconds) Loss of line power results in no LED output and no continuous trip GFCI Test Instructions 1. Turn “OFF” the GFCI Breaker actuator. Turn on the power to the panel. The green and red LED’s should be off. 2. Turn “ON” the GFCI Breaker actuator. The green “POWER” LED should show steady illumination and the red “LEAKAGE FAULT” LED should flash every 3 seconds to indicate a successful self-test. 3. Depress the “TEST” button. This will cause the actuator to move to the “OFF” position and the red LED to turn on and show steady illumination, indicating that the GFCI is functioning properly. The green LED will also go from steady to off. If the actuator fails to move to the “OFF” position or the red LED fails to illuminate, the unit MUST be replaced. 4. Turn the GFCI Breaker actuator to the “ON” position. The red LED should flash every 3 seconds and the green LED should show steady illumination. 5. This test is to be performed on a monthly basis and recorded on the “Monthly Test Reminder” label. ELCI LED Indication Indicator - Two integrated LEDs, Red & Green • Green LED On, Red LED Off - Line Voltage is present, the breaker is closed, and the device is protecting the circuits against over current and leakage current. • Green LED Off, Red LED On - The device has detected leakage current and has opened the circuit breaker. • Green LED Flashing, Red LED Off - The circuit breaker has opened due to over current or has been turned off manually • Green LED Off, Red LED Off - Line Voltage is not present • Green LED Flashing, Red LED Off, Amber LED ON - Indicates Hot & Neutral are reversed and the circuit breaker is open Neutral Protection - When neutral is grounded on load side of circuit Test Button - Located on Ground Fault Module Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 6 PC-Series Circuit Breaker - Ordering Scheme PC B B A 24 620 1 B A A 10 1 2 3 4 5 6 7 8 9 10 11 Terminal Actuator Mounting/ Trip Level Agency Series System Circuit Actuator Frequency Current Rating Color Barriers Approval Voltage/Poles & Delay 1 SERIES 6 CURRENT RATING (AMPERES) CODE AMPERES PC 410 1.000 445 4.500 610 10.000 618 18.000 512 1.250 450 5.000 710 10.500 620 20.000 4 2 SYSTEM VOLTAGE / POLES 415 1.500 455 5.500 611 11.000 622 22.000 A 120 VAC single phase, 1 pole 517 1.750 460 6.000 711 11.500 624 24.000 B 120/240 VAC single phase, 2 pole 420 2.000 465 6.500 612 12.000 625 25.000 C 120/240 VAC single phase with switched neutral, 3 pole 522 2.250 470 7.000 712 12.500 630 30.000 D 120 VAC single phase with switched neutral, 2 pole 425 2.500 475 7.500 613 13.000 635 35.000 G 240 VAC single phase, 2 pole 527 2.750 480 8.000 614 14.000 640 40.000 430 3.000 485 8.500 615 15.000 650 50.000 435 3.500 490 9.000 616 16.000 3 CIRCUIT 440 4.000 495 9.500 617 17.000 B Series Trip (Current) 7 TERMINAL 4 ACTUATOR 1 Stud, 10-32 threaded Handle Single Color Curved Rocker A 1 per breaker pole Push-to-Reset B 1 per unit R Vertical legend 8 ACTUATOR COLOR & LEGEND Two Color Curved Visi- U Horizontal legend Handle Rocker Actuator Color Rocker Two Color Flat Visi-Rocker Actuator Color I-O ON-OFF Dual Single Visi-Rocker C Indicate ON, 1 Indicate OFF, White A B 1 Black White vertical legend vertical legend Black C D 2 White N/A D Indicate ON, 2 Indicate OFF, Red F G 3 White Red horizontal legend horizontal legend Green H J 4 White Green F Indicate OFF, Single Color Flat Rocker Blue K L 5 White Blue vertical legend 3 Vertical legend Yellow M N 6 Black Yellow G Indicate OFF, 4 Horizontal legend Gray P Q 7 Black Gray horizontal legend Two Color Flat Visi-Rocker Orange R S 8 Black Orange Single Color Curved Rock- Push-to-Reset er 5 Indicate OFF, J Vertical legend vertical legend 9 MOUNTING / BARRIERS K Horizontal legend 6 Indicate OFF, MOUNTING STYLE BARRIERS Two Color Curved Visi- horizontal legend Threaded Insert, 2 per pole Rocker Single Color Flat Rocker A 6-32 X 0.195 inches yes Push-to-Reset Push-to-Reset B ISO M3 x 5mm yes N Indicate OFF, 7 Vertical legend Rockerguard Bezel Vertical legend 8 Horizontal legend Threaded Insert, 2 per pole O Indicate OFF, C 6-32 X 0.195 inches yes Horizontal legend D ISO M3 x 5mm yes Standard Bezel with Recessed Off-Side Flat Rocker Threaded Insert, 2 per pole E 6-32 X 0.195 inches yes F ISO M3 x 5mm yes Push-to-Reset Bezel Threaded Insert, 2 per pole G 6-32 X 0.195 inches yes H ISO M3 x 5mm yes 10 LEAKAGE CURRENT TRIP LEVEL - MAX. TRIP CURRENT 2 A 6 MA (CLASS A GFCI) 1,3 5 FREQUENCY & DELAY E 30 MA (ELCI) 20 50 / 60Hz Instantaneous 21 50 / 60Hz Ultra Short 11 AGENCY APPROVAL 22 50 / 60Hz Short AA without Approvals 24 50 / 60Hz Medium 2 10 UL 943 and CSA certified 26 50 / 60Hz Long 1,3 11 UL 1053 1,3 12 UL 1053 & UL 1500 Notes: 1 This device meets the requirements of ABCY E11. 2 6mA per UL943, available with agency code 10. 3 30mA per UL1053, available with agency approval codes 11 & 12. 4 Agency approval code 10 only available with system voltages A, B, C and D. COS-8048 Rev: F Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | PC-Series Circuit Breaker - Actuator Styles 7 Dimensional Specifications: in. [mm] INDICATE OFF / SINGLE COLOR HANDLE / INDICATE ON TERMINAL HANDLE / INDICATE ON TERMINAL INDICATE OFF / SINGLE COLOR ROCKER ACTUATOR ROCKER ACTUATOR LOCATIONS LOCATIONS ROCKER ACTUATOR ROCKER ACTUATOR 120 VAC PCA 120 VAC VERSION NOTE: NEUTRAL - SUPPLIED 12" LONG MIN. (CIRCUIT CODES A,B,E & F) 3.790 [96.27] 3.040 [77.22] 3.040 [77.22] 2.280 [57.91] 2.280 [57.91] .156 DIA. [Ø3.96] 2 PLC'S. TYP. PER POLE 1.660 [42.16] 1.453 [36.91] 1.260 [32.00] PCB 2.062 [52.37] 120/240 VAC VERSION .200 [5.08] PCA, PCB PCD & PCE .432 [10.97] .750 [19.05] PCC & PCF TYP. PCA PCB, PCD & PCE PCC & PCF 3.015 [76.58] HANDLE ACTUATOR ROCKER ACTUATOR MAX. PANEL CUTOUT DETAIL TOLERANCES ±.005 [.12] PCC 120/240 VAC VERSION W/ NEUTRAL BREAK 3.775 [95.88] MAX. PCD 120 VAC VERSION W/NEUTRAL BREAK Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com INDICATE OFF / SINGLE COLOR HANDLE / INDICATE ON TERMINAL HANDLE / INDICATE ON TERMINAL INDICATE OFF / SINGLE COLOR ROCKER ACTUATOR ROCKER ACTUATOR LOCATIONS LOCATIONS ROCKER ACTUATOR ROCKER ACTUATOR 120 VAC PCA 120 VAC VERSION | 8 PC-Series Circuit Breaker - Dimensional Specifications & Panel Cut Out Dimensional Specifications: in. [mm] NOTE: NEUTRAL - SUPPLIED 12" LONG MIN. (CIRCUIT CODES A,B,E & F) LOAD NEUTRAL LOAD NEUTRAL 3.790 [96.27] 3.040 [77.22] 3.790 [96.27] 3.040 [77.22] 3.040 [77.22] 3.040 [77.22] 2.280 [57.91] 2.280 [57.91] .156 DIA. [Ø3.96] 2.280 [57.91] 2 PLC'S. TYP. 2.280 [57.91] .156 DIA. [Ø3.96] PER POL 2E PLC'S. TYP. PER POLE 1.660 [42.16] 1.660 [42.16] 1.453 [36.91] 1.453 [36.91] 1.260 [32.00] 1.260 [32.00] PCB 2.062 [52.37] 2.062 [52.37] SOURCE SOURCE LINE 1 LINE 1 LINE 2 LINE 1 LINE 2 NEUTRAL NEUTRAL 120/240 VAC VERSION .200 [5.08] PCA, PCB .200 [5.08] PCD & PCE PCA, PCB .432 [10.97] PCD & PCE .750 [19.05] .432 [10.97] PCC & PCF TYP. .750 [19.05] PCC & PCF TYP. PCA SOURCE SOURCE PCB, PCD & PCE PCA NEUTRAL NEUTRAL LOAD HOT 2 LOAD HOT 2 PCC & PCF PCB, PCD & PCE 3.015 LINE 2 OR 230V NEUTRAL [76.58] LOAD HOT PCC & PCF OR 230V NEUTRAL LOAD HOT 1 LINE 2 HANDLE ACTUATOR ROCKER ACTUATOR MAX. LINE LOAD HOT 1 LINE 1 LINE 1 HANDLE ACTUATOR ROCKER ACTUATOR PANEL CUTOUT DETAIL TOLERANCES ±.005 [.12] PANEL CUTOUT DETAIL 1-Phase 120 VAC 1-Phase 120 / 240 VAC 1-Phase 240VAC TOLERANCES ±.005 [.12] with Neutral Switching with Neutral Switching 2.265 [57.53] MAX. 1.510 PCC 0.430 2.975 0.275 [38.35] [10.92] [75.57] [6.99] 120/240 VAC 0.750 TYP. VERSION [19.05] W/ NEUTRAL BREAK 2.518 [63.96] 1.453 3.775 2.062 [36.91] 3.800 [95.88] [52.37] [96.52] MAX. 0.429 [10.91] PCD 0.350 120 VAC [8.89] VERSION W/NEUTRAL BREAK NEUTRAL PIGTAIL (CIRCUIT CODE A+B ONLY) #6/32 / M3 MOUNTING INSERTS 0.125 [3.18] 1.245 0.208 1.660 [31.62] [5.28] [42.16] 0.100 [2.54] Notes: For additional circuit breaker dimensions, reference the C-Series Breakers in the Carling Circuit Protection catalog Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com PC-Series Circuit Breaker - Panel Seal Ordering Scheme, Dimensional Specifications | 9 8 PC 1 4 1 1 2 3 4 5 Type Series Actuator Poles Mounting Number 1 1 TYPE NUMBER 5 MOUNTING SCREWS / PLATE MATERIAL 8 Circuit Breaker Assembly 1 6-32 Thread Phillips Head 2 M-3 Thread Phillips Head 3 6-32 Thread Slotted Head 2 SERIES 4 M-3 Thread Slotted Head PC 5 6-32 Thread Phillips Head with Stainless Steel Plate 6 M-3 Thread Phillips Head with Stainless Steel Plate 7 6-32 Thread Slotted Head with Stainless Steel Plate 3 ACTUATOR TYPE 8 M-3 Thread Slotted Head with Stainless Steel Plate 1 Handle, one per pole 2 Handle, one per multipole unit A Rocker Notes: 1 Screws supplied to accommodate mounting panel thickness of 1/8” ± 1/32”. Consult Factory for additional options 4 POLES PER UNIT - INCLUDING ELECTRONIC MODULE 2 Available for Flat and Curved Rocker options - No Rockerguard Bracket 3 Three 4 Four 5 Five Handle Style Panel Seal Rocker Style Panel Seal Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 10 PC-Series Circuit Breaker - Panel Seal Configuration - Dimensional Specifications Handle Actuator Rocker Actuator Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com PC-Series Circuit Breaker - Time Delay Curves | 11 Time Delay Curves Instantaneous Medium Ultra Short Long Short Time Delay Values Percent of Rated Current Delay 100% 125% 150% 200% 400% 600% 800% 1000% 1200% 20 No Trip May Trip .040 MAX .035 MAX .030 MAX .025 MAX .020 MAX .017 MAX .015 MAX 21 No Trip .014 - .150 .011 - .095 .008 - .055 .006 - .035 .005 - .027 .005 - .021 .004 - .018 .004 - .017 22 No Trip .700 - 12.0 .350 - 4.00 .130 - 1.30 .027 - .220 .008 - .130 .004 - .090 .004 - .045 .004 - .040 24 No Trip 10.0 - 160 6.00 - 60.0 2.20 - 20.0 .300 - 3.00 .050 - 1.30 .007 - .500 .005 - .060 .005 - .040 26 No Trip 50.0 - 700 32.0 - 350 10.0 - 90.0 1.50 - 15.0 .500 - 7.00 .020 - 3.00 .006 - 2.00 .005 - 1.00 Notes: Other time delay values available, consult factory. Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | 12 Sales Representatives, Distributors & Company Profile Authorized Sales Representatives and Distributors Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. CANADA EUROPE USA MIDDLE EAST MEXICO AFRICA ASIA-PACIFIC OCEANIA SOUTH AMERICA About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com | Notes 13 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 @ Email: sales carlingtech.com @ Northern Region Sales Office: nrsm carlingtech.com @ Southeast Region Sales Office: sersm carlingtech.com @ Midwest Region Sales Office: mrsm carlingtech.com @ West Region Sales Office: wrsm carlingtech.com @ Latin America Sales Office: larsm carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Suite 1607, 16/F Tower 2, The Gateway, Harbour City, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 @ Email: sales carlingtech.com.hk @ Shenzhen, China: shenzhen carlingtech.com @ Shanghai, China: shanghai carlingtech.com @ Pune, India: india carlingtech.com @ Kaohsiung, Taiwan: taiwan carlingtech.com @ Yokohama, Japan: japan carlingtech.com | | Europe Middle East Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 @ Email: ltd.sales carlingtech.com @ Germany: gmbh carlingtech.com @ France: sas carlingtech.com www.carlingtech.com REV_04_2018
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the PCB-B3-26-650-12E-E11?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Manufacturers



What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods