CARLING TECHNOLOGIES PDB-B-24-650-E-2A1-1-C
Specifications
Manufacturer
Carling Technologies
Manufacturers Part #
PDB-B-24-650-E-2A1-1-C
Industry Aliases
PDB-B-24-650-E-2A1-1-C
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized overload and short circuit protection. In addition, this breaker senses and guards against faults to ground using a state of the art integrated circuit developed by Carling. This new technology detects faults and when a fault occurs, the breaker trips and an LED illuminates. The LED gives a clear indication that the trip occurred as a result of leakage. This protection helps prevent serious equipment damage and fire. Features: Overload, short circuit and ground fault protection in a single package Handle style actuators with optional “handleguard” Wiping Contacts - Mechanical linkage with two-step Agency Certifications: actuation – cleans contacts, provides high, positive contact pressure & longer contact life UL Standard 1077 Component Recognition Program as A trip-free mechanism, a safety feature, makes it Equipment Leakage Circuit Interrupter impossible to manually hold the contacts closed during and, Protectors, Supplementary (FTTJ2, File overload or fault conditions. E177510). A common trip linkage between all poles, another safety UL Standard 943 Tested as Ground Fault Circuit Interrupters feature, ensures that an overload in one pole will trip all for Equipment Protection. adjacent poles. CSA Certified Component Equipment Leakage Current Front panel or DIN rail mounting options Interrupter with Supplementary Protector, “State of the art” integrated circuit developed by Carling under Class C22.2,No. 144-M91, FIle Equipment leakage sensitivity from 10 to 100 milliamps LR47848-50 Integral push-to-test button and LED “tripped” indicator TUV Certified IEC 947-2 and appendix B: Circuit Breakers Immediate reset after fault has been cleared incorporating Residual Current Protection. Complies with waveform requirements of IEC 1008-1, Type A. Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062-1177 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: sales@carlingtech.com • www.carlingtech.com | 2 PD-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Certified configurations and Table B: Lists TUV Certified configurations and performance capabilities performance capabilities as a Component Supplementary Protector. as a Circuit breaker incorporating residual current protection. PD-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTOR & EARTH LEAKAGE CURRENT INTERRUPTER INTERRUPTING LEAKAGE VOLTAGE CURRENT RATING CAPACITY (AMPS) CURRENT FULL GENERAL UL / CSA MUST - TRIP CIRCUITR MAX ATING LOAD PURPOSE WITHOUTRATING FREQUENCY CONFIGURATION VOLTS HERTZ PHASE AMPS AMPS BACKUP FUSE(MILLIAMPS) 120/208 50/60 1 1-50 --- 5000 7-100 120/208 50/60 3 1 1-50 --- 5000 7-100 SERIES 208-240 50/60 3 1-50 --- 2000 7-100 480Y 50/60 3 1-30 30.1-50 2000 7-100 Electrical Mechanical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz Endurance 10,000 ON-OFF operations @ 6 per Standard Current Ratings 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, minute; with rated current and voltage. 20.0, 25.0, 30.0, 35.0, 40.0 & 50.0 Trip Free All SmartGuard equipment leakeage amps. For other ratings, consult factory. circuit breakers will trip on overload Insulation Resistance Minimum of 100 Megohms @ 500 VDC. or leakage to ground, even when Dielectric Strength 1960 VAC, 60 Hz for one minute actuator is forcibly held in the ON between all electrically isolated position. terminals. Trip Indication The actuator moves to the OFF Resistance, Impedance from Line to Load Terminal position when an overload or earth (Values Based on Series Trip Circuit leakage ground fault causes the Breaker) breaker to trip. The LED is illuminated RESISTANCE, IMPEDANCE VALUES when leakage to ground causes the from Line to Load Terminals Ampere Rating circuit breaker to trip. Physical Number of Poles 2, 3 & 4 20.1 - 50.0 Length (included switched or unswitched neutral) 4.2 inches ( 106.7 mm) Pulse Tolerance Curve Width 2-pole: 3.0 inches (76.2 mm) 60 Hz 1/2 Cycle Inrush Pulse Tolerance I r 3-pole: 3.75 inches (95.3 mm) 4-pole: 4.5 inches (114.3 mm) Time Delay Curves Depth 2.5inches (63.5mm). 22, 24, 26 12x Weight: 2-pole 16.0 oz. (453.6 gm) t 3-pole: 21.4 oz. (606.7 gm) 8.33 16.67 4.165 Time in 4-pole: 26.9 oz. (762.6 gm) Milliseconds Standard Colors Housing - gray; Actuator - black, red, or white Mounting Front Panel or Standard 35mm Symmetrical DIN Rail (35 x 7.5 or Leakage To Ground 35 x 15mm per DIN EN5002). Standard Must Trip Termination Box Lug Leakage Current Ratings 7, 10, 15, 30, 50 & 100 milliamps. For other ratings, consult factory. Environmental Trip Time 300 ms Max. @ 100%, 40ms Max. @ 500% of must trip leakage current. Operating Temperature +10°C to +50°C Test Button On breaker face above actuator. Leakage Trip Indicator Red LED on breaker face above actuator. *Manufacturer reserves the right to change product specification without prior notice. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Multiple of Rated Current | PD-Series – Circuit & Terminal Diagrams 3 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. Notes: Other time delay values available, consult factory. Delay Curves 21,22,24,26: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curve 20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capability is 12 times the rated current. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com | PD-Series – Circuit & Terminal Diagrams 4 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com | PC-Series – Ordering Scheme 5 PD R – B – 24 – 650 – B – 2 A 1 – 1 – C 1 2 3 4 5 6 7 8 9 10 11 Series System Circuit Frequency Current Rating Equipment Terminal Actuator Actuator Mounting Agency Leakage - Color Approval Voltage/Poles & Delay Trip Current 2 1 SERIES 6 EQUIPMENT LEAKAGE - TRIP CURRENT (MILLIAMPS) PD B 7 D 15 F 50 C 10 E 30 G 100 1 2 SYSTEM VOLTAGE / POLES System Voltage Poles 7 TERMINAL A 120VAC 1Ø One plus unswitched neutral 2 Front Connected Box Lug B 120/240 VAC 1Ø Two C 120/208 VAC 1Ø, Two plus unswitched neutral 120/240 VAC 1Ø 8 ACTUATOR D 120/208 VAC 1Ø, Two plus switched neutral A Handle 120/240 VAC 1Ø B Handle w/ handleguard E 208/240 VAC 3Ø Three F 208/240 VAC 3Ø Three plus unswitched neutral G 208/240 VAC 3Ø Three plus switched neutral 4 P 480Y VAC 3Ø Three 9 ACTUATOR COLOR & LEGEND Q 480Y VAC 3Ø Three plus unswitched neutral Acuator Color I-O Legend Color ON-OFF Dual R 480Y VAC 3Ø Three plus switched neutral White A Black B 1 Black C White D 2 Red E White F 3 3 CIRCUIT B Series Trip (Current) 3 10 MOUNTING 1 THREADED INSERT 6-32 X 0.195 INCHES 4 FREQUENCY & DELAY 2 THREADED INSERT ISO M3 X 6.5 MM 20 50/60Hz Instantaneous 24 50/60Hz Medium 22 50/60Hz Short 26 50/60Hz Long 11 AGENCY APPROVAL C UL Recognized & CSA Certified 5 CURRENT RATING (AMPERES) U TUV Certified CODE AMPERES 410 1.000 445 4.500 610 10.000 618 18.000 512 1.250 450 5.000 710 10.500 620 20.000 Notes: 415 1.500 455 5.500 611 11.000 622 22.000 1 Units with a switched or unswitched neutral connection are the same size as a unit with 517 1.750 460 6.000 711 11.500 624 24.000 an additional breaker pole (e.g. a 2-pole unit with a switched or unswitched neutral is the same physical size as a 3-pole unit.) 420 2.000 465 6.500 612 12.000 625 25.000 Switched neutral poles contain the same overcurrent protection as the other poles. 522 2.250 470 7.000 712 12.500 630 30.000 2 The leakage currents shown will cause the breaker to trip (must-trip current). The must- 425 2.500 475 7.500 613 13.000 635 35.000 hold current is 67% of the must-trip current. 527 2.750 480 8.000 614 14.000 640 40.000 3 All breakers are front panel mountable using screw size shown. Breakers may also be 430 3.000 485 8.500 615 15.000 650 50.000 mounted on either 35mm x 7.5mm or 35mm x 15mm symmetrical DIN rail. 435 3.500 490 9.000 616 16.000 4 TUV certifed units must have I-O or Dual legends 440 4.000 495 9.500 617 17.000 Time Delay Curves Instantaneous Medium Short Long REV_GFCI_PD_0312 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: sales@carlingtech.com • www.carlingtech.com Email: sales@carlingtech.com • www.carlingtech.com
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the PDB-B-24-650-E-2A1-1-C?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Circuit Breaker 1Pole 30A 277VAC/80VDC A-Series: 1-6 poles, 0.02 to 50 amps, up to 277VAC or 80VDC; ...
Manufacturers



What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods