Switch Rocker (ON) None OFF SPST Quick Connect Rocker/Paddle Rocker 20A 12VDC 150000Cycles Automotive Bulk
Sealed 1 to 2 pole rocker switches with 8 & 10 terminals; certified to IP66/IP68 above panel. Operating temperature -40°C to 85°C. Several actuator styles including paddle, locking and illuminated lens options. UL, CSA, VDE, UL1500. See datasheet.

Part Number

V2D1B60B-00000-000

Price

Request Quote

Manufacturer

CARLING TECHNOLOGIES

Lead Time

Request Quote

Category

Switches »  Switch Rocker

Specifications

Manufacturer

Carling Technologies

Manufacturers Part #

V2D1B60B-00000-000

Industry Aliases

V2D1B60B-00000-000

Sub-Category

Rocker Switches

Packaging

Bulk

Factory Pack Quantity

1

Datasheet

pdf file

V-Series_Details_%26_COS_a.pdf

5683 KiB

Extracted Text

V-Series Contura Switches Product Highlights: Š Maximum sealing protection with dual seals around lamps and rocker stem, certified to IP66 & IP68. Optional panel seals for additional protection. Š Silver plated butt contact mechanism provides 50 to 100 thousand electrical cycles and a variety of different CONTURA III CONTURA II electrical ratings. Š Roller pin mechanism does not require lubricants and allows the switch to withstand extreme temperatures. Š The switch base accommodates up to 10 terminals and a large variety of switch and lighting circuits. Š The multi-step mounting wings provide a secure fit for panel thicknesses of 0.032” thru 0.250” in an industry standard 0.830” x 1.450” mounting hole. Š The switch connector allows the user to preload FQC CONTURA V CONTURA VII terminals for easy assembly to switch base. Š Numerous choices of removable rockers allow for style change without having to retest or re-qualify the switch Carling Technologies’ fully sealed V-Series Contura switches base. are well known for their cutting edge design, high quality, Š Illumination options are endless with bar, oval, and square maximum performance and unmatched reliability. These lenses available with choices of incandescent, neon and switches are a staple in the marine and transportation a wide variety of LEDs including superbrite, megabrite, industries and have passed a range of environmental, flashing and bicolor lighting. corrosion, temperature, vibration, shock and sealing tests Š Available with a variety of complimentary mounting including MIL Std 202F, MIL Std 810C, UL 1500, ISO 8846, IEC panels, hole plugs, illuminated indicators and boots to 60529 and BS 5490 among others, making them one of the accommodate most any design need. most rugged and reliable switches ever manufactured. Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: sales@carlingtech.com Application Support: team2@carlingtech.com Phone: (860) 793-9281 • Fax: (860) 793-9231 www.carlingtech.com | 2 V-Series Contura Sealed Rocker Switches V-Series Switch DESIGN FEATURES INTERCHANGEABLE ACTUATORS DUAL SEAL PROTECTION CLEAN CONNECTIONS Panel redesign is a snap with our wide Seals out water, dust, Options for both eight and ten range of rocker styles. Achieve maximum debris, and enables switch terminal base styles with AMP & design variety with minimum inventory. certification to IP66/IP68 for Packard compatible connectors Simply swap rockers to create an entirely front panel components. affords myriad circuit options new look for your panel. while providing ease of assembly. MULTIPLE LIGHTING OPTIONS BRASS ROLLER PIN SILVER PLATED BUTT OPTIONAL PANEL SEAL In addition to Incandescent Robust mechanism CONTACT MECHANISM Prevents water/dust lamps, our LED illumination is eliminates the need for Providing 50k to 100k ingress behind panel. offered in a wide array of light lubricants. Enables switch electrical cycles and intensities, colors, as well as to withstand -40°C to a variety of different dual level, tri-color, and flashing +85°C temperatures. electrical ratings. options. Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | V-Series Contura Sealed Rocker Switches & Illuminated Plug 3 Contura II & III Contura X The Contura II & III actuators are The raised bracket/bezel on constructed of thermoplastic the Contura X helps prevent polycarbonate and are offered inadvertent actuation of the with a hard nylon overlay or a rocker, as well as preventing “soft-touch” elastomer overlay. debris from being trapped under These models incorporate the actuator. This curved rocker aesthetic designs on the top and style is available with a variety of bottom of the rocker featuring lenses and legends. two rows of raised “bumps” on the Contura II and three “indented” lines on the Contura III. Contura IV Contura XI The Contura IV’s “Shape to create The raised bracket/bezel on a Shape” actuator works with the the Contura XI helps prevent curves, contours & advanced inadvertent actuation of the styling of the latest panel designs, rocker, as well as preventing debris flowing with these advanced from being trapped under the curves & radii. This actuator style actuator. This convex style rocker fits on the Contura flush bracket/ is available with a wide variety of bezel. lenses and legends. Contura XII Contura V The Contura XII version features The symmetrically curved a paddle style actuator with Contura V actuator provides the raised bracket/bezel of the perfect complement to the Contura X and XI. The contoured Contura IV’s “Shape to create a handle design provides intuitive Shape” design concept. With its recognition and ease of operation flush style mounting bracket, and is available with all Contura X Contura V can be mounted in and XI lens and legend offerings. between two Contura IV’s, by itself, or in groups. Contura VI (WAVE) Contura XIV The Contura VI WAVE sealed The Contura XIV represents a sleek rocker switches, when used in a new crossover rocker design which row, create an uniquely appealing should appeal to Trucks, Buses and “wave” design on your panel. A Heavy Vehicles as well as the Marine variety of colors and finishes are Industry. Intuitive feel is provided by available for both rocker and wave recessed ridges along with a Center insert. Contura VI features bar and Groove which effectively defines the oval lenses. boundary between top and bottom switch functions. Contura VII V-Series Illuminated Contura VII featuring gently Indicators & Accessories curved corners and edges Alert operator of systems functions assuring compatibility with most or malfunctions, are offered with any panel design. Intuitive feel removable/replaceable lamps in is maximized by the use of 2 Contura II, II, V or X styles. Accessories embossed circular pads located at include connectors, mounting opposite ends of the rocker. Any panels, hole plugs, panel seals, and combination of Bar or Oval style actuator removal tools. Refer to lenses can be located in the pads accessories page for full details providing a truly unique look, exclusive to Contura VII. Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | 4 V–Series Contura Sealed Rocker Switches - General Specifications Electrical Agency Certifications Contact Rating .4VA @ 24VDC (MAX) resistive 15 amps, 125VAC 10 amps, 250VAC 1/2 HP 125-250VAC Environmental 20 amps, 4-14VDC Sealing Sealed version: IP68, in accordance 15 amps, 15-28VDC with IEC 60529, BS 5490, DIN 40050 10A, 14VT & NFC 20 010. This rating applies to front panel components of the actual 6A, 125VAC L switch only, and signifies protection Dielectric Strength 1500 Volts RMS against dust and the prolonged Insulation Resistance 50 Megohms effects of immersion under pressure. Initial Contact Resistance 10 milliohms max. @ 4VDC The standard test for immersion Life 50,000- 100,000 cycles circuit under pressure requires submersion dependent under one meter of water for 30 min. Contacts Silver alloy, silver tin-oxide, fine The V-Series switch has exceeded silver these parameters, having Terminals Brass or copper/silver plate 1/4” been actuated and illuminated during (6.3mm) Quick Connect submersion. Corrosion Mixed Flowing Gas (MFG) Class III terminations standard. Solder lug, 3 year accelerated exposure per Wire Lead ASTM B-827, B-845 Silver and gold Mechanical contacts Endurance 150,000 cycles minimum Operating Temp. -40°C to + 85°C Vibration 1 Per Mil-Std 202F, Method 204D circuit dependent Test Condition A 0.06 DA or 10G’s Physical 10-500 Hz. Tested with VCH connector. Test criteria - No loss of circuit during Lighted Incandescent - rated 10,000 test, pre and post test contact hours Neon - rated 25,000 hours resistance. LED - rated 100,000 hours 1/2 life Vibration 2 Resonance search (LED is internally ballasted for 24-50 Hz 0.40 DA voltages to 24VDC) 50-2000 Hz ±10 G’s peak Seals Internal Horizontal Axis 3-5 G’s max. Optional external gasket panel seal Random Base Polyester blend rated to 125°C with 24 Hz 0.06 PSD-Gsq/Hz a UL flammability rating of 94V0. 60 Hz 0.50 Contura II,III,IV,V, Hard Surface: Basic actuator 100 Hz 0.50 200 Hz 0.025 VI, VII Actuator structure molded of thermoplastic 2000 Hz 0.025 polycarbonate with a hard Nylon 66 No loss of circuit during test; <10μ thermoplastic surface overlay. seconds chatter. Soft Surface: Basic actuator structure Shock Per Mil-Std 202F, Method 213B, Test molded of thermoplastic polycarbonate Condition K @ 30G’s. Tested with with an elastomer overlay. VCH connector. Test criteria - No loss Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C of circuit during test, pre and post Lens Polycarbonate rated at 100°C test contact resistance. Contura XIV Polycarbonate lens/subrocker with Salt Spray Per Mil-Std 202F, Method 101D, Test ABS shell Condition A, 96 Hrs. Sealed version only. Dust Per Mil-Std 810C, Method 510.2 Air Actuator Travel (Angular Displacement) Velocity 300 ±200 Feet/Min, Test 2 position 18° Duration 16 Hrs. Thermal Shock Per Mil-Std 202F, Method 107F, Test 3 positions 9° from center Cond. A, -55°C to 85°C. Test criteria - pre and post test contact resistance Mounting Specifications Moisture Resistance Per Mil-Std 202F, Method 106F, Test .830[21.08] Panel Thickness Range Criteria - pre and post test contact Gaskets Acceptable Panel Thickness resistance Ignition Protection All Contura switches with sealed 0 .030 to .250 (.76mm to 6.35mm) TEST CUT HOLE IN 1.450[36.83] construction meet the requirements 1 .030 to .109 & .147 to .157 ACTUAL MATERIAL of UL1500/ISO8846 for ignition (.76 to 2.77mm & 3.73 to 3.98mm) protection, in addition to Recommended: No gasket with panel conformance with EC directive SWITCH thickness of .032, .062, .093, .125,.187 or .250 MOUNTING HOLE 94/25/EC for marine products. Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | V–Series Contura II, III, & IV 5 Dimensional Specifications: in. [mm] Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | 6 V-Series Contura V, VI & VII Dimensional Specifications: in. [mm] CONTURA V CONTURA V CONTURA VI CONTURA VII SHOWN WITH SHOWN WITH SHOWN WITH OVAL SHOWN WITH LARGE LENS BAR LENS LOW PROFILE LOCK LENS AND BAR LENS 1.922[48.56] 1.922[48.82] 1.922[48.56] .080[2.03] 1.950[49.53] 1.079 [27.40] 1.126 1.479 1.550 [37.57] [39.37] 10 TERMINAL BASE 8 TERMINAL BASE 8 TERMINAL BASE W/BARRIER AND 10 TERMINAL BASE W/BARRIERS W/O BARRIERS LAMP TERMINAL W/O BARRIERS 1.020 1.020 0.985 1.000 [25.91] [25.91] [25.02] [25.40] .505 .505 [12.83] [12.83] .250 [6.35] .250 [6.35] .250 .250 X .031 [.78] [6.35] [6.35] .031 X X .031 [.78] .031 .820 [.78] .820 [.78] [20.83] [20.83] .820 .960 .390 [20.83] [24.38] .960 [9.90] [24.38] .960 .960 [24.38] [24.38] 8 TERMINAL BASE 8 TERMINAL BASE 10 TERMINAL BASE 10 TERMINAL BASE W/O BARRIERS W/BARRIERS W/O BARRIERS W/O BARRIERS 8 7 8 7 1 4 2.029 1 4 [51.53] 2 5 2 5 3 6 3 6 10 9 SWITCH SHOWN WITH BOTTOM VIEW BOTTOM VIEW VCH CONNECTOR 8 TERMINAL TERMINAL SWITCH SHOWN WITH TERMINAL ARRANGEMENT ARRANGEMENT VC1 CONNECTOR 10 SWITCH SHOWN 8 TERMINAL BASE 10 TERMINAL BASE TERMINAL WITH VC1 CONNECTOR 10 TERMINAL Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | V-Series Contura X, XI, XII & XIV 7 Dimensional Specifications: in. [mm] CONTURA X STYLE CONTURA XI STYLE CONTURA XII STYLE CONTURA XIV STYLE SHOWN WITH RAISED BRACKET SHOWN WITH RAISED SHOWN WITH PADDLE SHOWN WITH LARGE LENS BRACKET AND TWO SQUARE ACTUATOR LENSES 1.928 [48.97] .667 [16.94] .350 1.910[48.51] 1.910[48.51] .426[10.82] [8.89] .573 1.305[33.15] [14.56] .350[8.89] 1.586[40.28] 1.506[38.25] 1.370[34.79] 1.370[34.79] 1.370[34.79] 8 TERMINAL BASE 10 TERMINAL BASE 8 TERMINAL BASE 10 TERMINAL BASE W/BARRIERS W/O BARRIERS W/O BARRIERS W/O BARRIERS .960[24.38] .970 [24.64] .960[24.38] .960[24.38] .780[19.81] .780[19.81] .780[19.81] .250[6.35] X .031[.78] .390[9.90] .390[9.90] .390[9.90] .820 .820[20.82] .820[20.82] [20.83] .820[20.82] .960 [24.38] 8 TERMINAL BASE 10 TERMINAL BASE 10 TERMINAL W/BARRIERS W/BARRIERS BASE W/O BARRIERS 8 7 8 7 1 4 1 4 2 5 2 5 3 6 3 6 10 9 BOTTOM VIEW BOTTOM VIEW SWITCH SHOWN WITH SWITCHES SHOWN WITH TERMINAL TERMINAL VCH CONNECTOR VC1 CONNECTOR ARRANGEMENT ARRANGEMENT 8 TERMINAL 10 TERMINAL 8 TERMINAL BASE 10 TERMINAL BASE Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | 8 V-Series Contura II to XIV - Circuit Diagram CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM CIRCUIT CIRCUIT DIAGRAM 3 3 6 13 46 1 A J 2 25 25 3 3 6 1 3 4 6 2 B K 2 2 5 2 5 3 3 6 1 34 6 3 C L 2 2 5 2 5 1 3 1 3 4 6 3 6 4 D M 2 2 5 2 5 1 3 13 4 6 1 3 6 5 E R 2 25 2 5 13 1 3 4 6 13 6 6 F S 2 2 5 25 13 3 6 SYMBOL LEGEND 7 G SYM. DEFINITION DESIGNATES TERMINALS AND CONTACTS 2 2 5 DESIGNATES LAMP LOCATION 1 3 3 4 DESIGNATES MAINTAINED CIRCUITS DESIGNATES OTHER POSITION DESIGNATES MOMENTARY CIRCUITS 8 H DESIGNATES TWO POSITION CONNECTION DESIGNATES EXTERNAL JUMPER PROVIDED 2 25 BY CUSTOMER Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | V-Series Contura II to XIV - Circuit Diagram 9 LAMP LAMP LAMP LAMP CIRCUIT DIAGRAM CIRCUIT DIAGRAM CIRCUIT DIAGRAM CIRCUIT DIAGRAM CIRCUIT CIRCUIT CIRCUIT CIRCUIT +3 +6 +8 +8 +3 -6 +3 -6 SPECIAL 1 2 1 1 2 1 A/1 F/6 L/9 #1 -7 -7 -7 +8 +6 +3 +8 +3 +3 -6 SPECIAL 1 2 1 12 2 B/2 G/7 M/R #3 -7 -7 -7 +8 +3 +3 +8 +1 +3 -4 -6 SPECIAL 1 2 2 2 1 2 C/3 H/Z N/T #4 -7 -7 -7 +1 -8 +3 +6 +1 +3 -4 -6 +3 D/4 1 2 J/8 12 P/V 1 2 -7 -7 +8 +10 +1 +3 +8 +6 U/Y 12 E/5 1 2 K/W 12 -7 -9 -7 (-)7 CIRCUIT CIRCUIT CIRCUIT CIRCUIT DIAGRAM CIRCUIT DIAGRAM CIRCUIT DIAGRAM CIRCUIT CIRCUIT CIRCUIT CIRCUIT DIAGRAM CIRCUIT DIAGRAM CIRCUIT DIAGRAM 13 17 18 10(-) 10(-) 1 3 17 18 11 11 11 11 13 13 13 13 31 3 3 3 14 14 14 4 6 NOTE: 1 3 17 18 10(-) 13 17 18 13 11 3 3 3 31 14 14 14 4 10(-) 6 J circuits are available for all non-locking V-Series J1 J5 2 JA 1 styles. Consult factory for J1 1 J5 2 JA p/n details. 2 2 5 58 8 2 5 8 5 2 28 5 5 8 2 58 5 11 11 11 11 13 13 13 13 3 3 3 3 14 17 18 10(-) 11 13 3 3 3 3 14 13 11 3 14 17 18 10(-) 1311 3 3 3 3 14 J2 1 JJ J2 1 JJ 58 5 8 13 17 18 10(-) 11 13 3 3 3 3 14 15 12 616 1 3 17 18 10(-) 1311 3 3 3 314 15 12 6 16 J3 1 JK J3 1 JK 2 5 8 25 8 13 17 18 10(-) 1 3 17 18 10(-) SYMBOL LEGEND SYM. DEFINITION J4 1 SYMBOL LEGEND CIRCUIT CONNECTOR PART # DESIGNATES TERMINALS AND CONTACTS J4 1 SYM. DEFINITION JA,JJ,JK JC1-01 DESIGNATES LAMP LOCATION J1,J3,J4,J5 JC2-01 DESIGNATES TERMINALS AND CONTACTS DESIGNATES TERMINALS AND CONTACTS 2 5 DESIGNATES LAMP LOCATION DESIGNATES LAMP LOCATION J2 JC3-01 5 2 DESIGNATES TWO PO DESIGNATES TWO POSITION CIRCUI SITION CIRCUIT T Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | 10 V-Series Contura II & III Sealed Rocker Switches - Ordering Scheme V 1 D A B T 0 B A R B 00 0 00 8 9 10 11 12 13 14 1 2 3 4 5 6 7 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Color Legend Legend Actuator Orientation Lens Legend 1 SERIES 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 12VDC C N H T 2 - - 5 2 - - 5 24VDC D P J V 3 - - 6 3 - - 6 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 1 A ON NONE OFF 8 FLUSH BRACKET COLOR , PANEL SEAL 2 B (ON) NONE OFF Black White Gray 3 C ON NONE (OFF) No Seal B W G 4 D ON NONE ON One Seal C Y H 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) 9 ACTUATOR SPECIAL CIRCUITS 0 No Actuator H* 2 & 3 2 & 3, 5 & 4 5 & 4 A, B Contura II G* 2 & 3, 5 & 6 2 & 3 OFF C, D Contura III S* 2 & 3, 5 & 6 2 & 3 1 & 2 M* (2 & 3, 5 & 6) 2 & 3 OFF 3,6 1,4 Actuator orientation above terminals: R* (2 & 3, 5 & 6) 2 & 3 2 & 1 E* 5 & 6 5 & 3 5 & 1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit 10 LENS E may be used for SP OFF-ON-ON circuit. 0 - No Actuator Z - No Lens Clear White Amber Green Red Blue 3 3 RATING 1 6 8 G M T 1 .4VA @ 28VDC Resistive 2 7 C H N U B 15A 24V 3 8 D J P V C 20A 18V 4 9 E K R W D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 5 A F L S Y F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V Lens color for LEDs must be clear, white, or match color of LED. N .4VA/15A 24V Green or blue lenses are not recommended with Neon lamps. 4 TERMINATION/BASE STYLE 1 11 ACTUATOR COLOR AND TEXTURE 8 term 10 Term Termination Jumper 0 - No Actuator 1 2 .250 TAB (QC) no barriers No Black Gray Red White A B .250 TAB (QC) with barriers No Soft Surface B G R W J K .250 TAB (QC) no barriers Yes T2 to 5 Hard Surface C H S Y 3 5 Solder Lug no barriers No C D Solder Lug No 5 6 Wire Leads no barriers No 2 E F Wire Leads No 12 ACTUATOR LENS OR BODY LEGENDS Note: Codes J & K for circuits H, G & M. 11 ON 12 OFF 13 I 14 O OFF ON O I 15 O O 16 O O 17 O I 18 I O 5 ILLUMINATION Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of F N N F switch. Positive (+) and negative (-) symbols apply to LED lamps only F F Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals For additional legend options & codes, visit us at www.carlingtech.com. S 0 NONE – – A 1 1 INDEPENDENT 8 (+) 7 (–) B 2 1 DOWN 3 (+) 7 (–) 13 LEGEND ORIENTATION C 3 2 UP 3 (+) 7 (–) 0 No legend (used with codes 11-18 in selection 12) D 4 1 DOWN 3 (+) 7 (–) 1 Orientation 1 2 DOWN 1 (+) 7 (–) 2 Orientation 2 E 5 1 UP 1 (+) 7 (–) 3 Orientation 3 2 UP 3 (+) 7 (–) 4 Orientation 4 F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) 14 ACTUATOR LENS LEGEND SINGLE POLE SWITCHES ONLY 00 No legend this location / no actuator J 8 1 DOWN 3 (+) 8 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch requires two 2 INDEPENDENT 6 (+) 7 (–) legends. If the two legends consist of one lens and one body legend, lens legend must K W 1 INDEPENDENT 8 (+) 7 (–) be specified in selection 12; body legend specified in selection 14. 2 INDEPENDENT 6 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. DOUBLE POLE SWITCHES ONLY L 9 1 DOWN 3 (+) 6 (–) Notes: M R 1 UP 3 (+) 6 (–) Consult factory to verify horsepower rating for your particular circuit choice. N T 1 DOWN 3 (+) 6 (–) 1 Custom colors are available. Consult factory. 2 DOWN 1 (+) 4 (–) 2 Body legends not available on Soft surface actuators; White imprinting is standard P V 1 UP 1 (+) 4 (–) on black actuators; Black imprinting is standard on white, red and gray actuators. 2 UP 3 (+) 6 (–) Custom colors are available, consult factory. 3 Additional ratings available. See V-Series Switch Accessories page. 4 Contura II available with two square lenses. Consult factory for details. Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | V-Series Contura II & III Locking Sealed Rocker Switches - Ordering Scheme 11 V 1 D A S W 0 B A Z E 00 0 8 9 10 11 12 13 1 2 3 4 5 6 7 Series Circuit Rating Termination Illumination Lock Lamp Bracket Actuator Lens Function Legend Legend Orientation 1 SERIES 7 LAMP V Lamp above terminals 3 & 6 end of switch No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 12VDC C N H T 2 - - 5 2 - - 5 24VDC D P J V 3 - - 6 3 - - 6 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 1 A ON NONE OFF 8 FLUSH BRACKET COLOR , PANEL SEAL 2 B (ON) NONE OFF Black White Gray 3 C ON NONE (OFF) No Seal B W G 4 D ON NONE ON One Seal C Y H 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 1 8 L (ON) OFF (ON) 9 HARD SURFACE ACTUATOR SPECIAL CIRCUITS Black Gray Red White H* 2 & 3 2 & 3, 5 & 4 5 & 4 Contura II A B G H G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1 & 2 Contura III C D E F M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 3,6 1,4 Actuator orientation above terminals: E* 5 & 6 5 & 3 5 & 1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 10 LENS Z - No Lens Clear White Amber Green Red Blue 4 3 RATING 3 8 D J P V 1 .4VA @ 28VDC Resistive B 15A 24V Lens color for LEDs must be clear, white, or match color of LED. C 20A 18V Green or blue lenses are not recommended with Neon lamps. D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) 1 M .4VA/20A 12V 11 ACTUATOR LOCK FUNCTION AND COLOR 3 N .4VA/15A 24V Lock Color Up Down Up & Down Center Match Actuator A H R 1 Black B J S 2 4 TERMINATION/BASE STYLE White C K T 3 8 term 10 Term Termination Jumper Red D L V 4 1 2 .250 TAB (QC) no barriers No Safety Orange E M W 5 A B .250 TAB (QC) with barriers No J K .250 TAB (QC) no barriers Yes T2 to 5 2 3 5 Solder Lug no barriers No 12 ACTUATOR LENS OR BODY LEGEND C D Solder Lug No 00 - No Legend 5 6 Wire Leads no barriers No 21 22 23 24 E F Wire Leads No OFF ON O I Note: Codes J & K for circuits H, G & M. 25 O 26 O 27 O 28 I F N 5 ILLUMINATION & SWITCH SEALING F Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of For additional legend options & codes, visit us at www.carlingtech.com. switch. Positive (+) and negative (-) symbols apply to LED lamps only Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals ORIENTATION OF S 0 NONE – – ACTUATOR/LENS IN PANEL 13 LEGEND ORIENTATION ORIENTATION 1 C 3 2 UP 3 (+) 7 (–) 0 No legend (used with codes 21-28 in selection 12) H Z 2 INDEPENDENT 8 (+) 7 (–) 1 Orientation 1 DOUBLE POLE SWITCHES ONLY 2 Orientation 2 M R 1 UP 3 (+) 6 (–) 3 Orientation 3 ORIENTATION 4 ORIENTATION 2 4 Orientation 4 AZC45-1 6 LOCK AZC45-2 45 Lock above terminals 1 & 4 end of switch. W lock 45 ORIENTATION 3 Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. 3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function. 4 Additional ratings available. See V-Series Switch Accessories page. Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | 12 V-Series Contura IV Sealed Rocker Switches - Ordering Scheme V 1 D A B T 0 B E P C 00 0 00 8 9 10 11 12 13 14 1 2 3 4 5 6 7 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Color Legend Legend Actuator Orientation Lens Legend 1 SERIES 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) V Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 12VDC C N H T 2 - - 5 2 - - 5 24VDC D P J V 3 - - 6 3 - - 6 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 1 A ON NONE OFF 8 FLUSH BRACKET COLOR , PANEL SEAL 2 B (ON) NONE OFF Black White Gray 3 C ON NONE (OFF) No Seal B W G 4 D ON NONE ON One Seal C Y H 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) 9 ACTUATOR 1,4 SPECIAL CIRCUITS 0 No Actuator H* 2 & 3 2 & 3, 5 & 4 5 & 4 E Contura IV, left orientation G* 2 & 3, 5 & 6 2 & 3 OFF T Contura IV, left orientation, laser etched S* 2 & 3, 5 & 6 2 & 3 1 & 2 F Contura IV, right orientation M* (2 & 3, 5 & 6) 2 & 3 OFF R Contura IV, right orientation, laser etched R* (2 & 3, 5 & 6) 2 & 3 2 & 1 3,6 Actuator orientation above terminals: E* 5 & 6 5 & 3 5 & 1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. 10 LENS 0 - No Actuator Z - No Lens Clear White Amber Green Red Blue 4 1 6 8 G M T 3 RATING 1 .4VA @ 28VDC Resistive 2 7 C H N U B 15A 24V 3 8 D J P V C 20A 18V 4 9 E K R W D 20A 12V 5 A F L S Y E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) E F F 10A 14V, 6A 14VT (circuit G only) Lens color for LEDs must be clear, white, or match color of LED. M .4VA/20A 12V Green or blue lenses are not recommended with Neon lamps. N .4VA/15A 24V 1,5,6 4 TERMINATION/BASE STYLE 11 ACTUATOR COLOR 8 term 10 Term Termination Jumper No Actuator 0 Black C Gray H Red S White Y Nickel D Pewter E 1 2 .250 TAB (QC) no barriers No A B .250 TAB (QC) with barriers No J K .250 TAB (QC) no barriers Yes T2 to 5 2 3 5 Solder Lug no barriers No 12 ACTUATOR LENS OR BODY LEGENDS C D Solder Lug No 11 ON 12 OFF 13 I 14 O 5 6 Wire Leads no barriers No OFF ON O I E F Wire Leads No 15 O O 16 O O 17 O I 18 I O Note: Codes J & K for circuits H, G & M. F N N F F F For additional legend options & codes, visit us at www.carlingtech.com. 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only ORIENTATION OF ACTUATOR/LENS IN PANEL Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 13 LEGEND ORIENTATION ORIENTATION 1 S 0 NONE – – 0 No legend (used with codes 11-18 in selection 12) A 1 1 INDEPENDENT 8 (+) 7 (–) 1 Orientation 1 B 2 1 DOWN 3 (+) 7 (–) 2 Orientation 2 C 3 2 UP 3 (+) 7 (–) 3 Orientation 3 D 4 1 DOWN 3 (+) 7 (–) ORIENTATION 4 ORIENTATION ORIENTATION 2 2 4 Orientation 4 2 DOWN 1 (+) 7 (–) E8C45-100 E3C70-200 E8C45-300 E 5 1 UP 1 (+) 7 (–) 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) F8C45-100 F3C70-200 F8C45-300 ORIENTATION 3 G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) 14 ACTUATOR LENS LEGEND U Y 1 INDEPENDENT 8 (+) 7 (–) 00 No legend this location / no actuator 2 INDEPENDENT 10 (+) 9 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch requires two SINGLE POLE SWITCHES ONLY legends. If the two legends consist of one lens and one body legend, lens legend must J 8 1 DOWN 3 (+) 8 (–) be specified in selection 12; body legend specified in selection 14. 2 INDEPENDENT 6 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. K W 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) Notes: DOUBLE POLE SWITCHES ONLY Consult factory to verify horsepower rating for your particular circuit choice. L 9 1 DOWN 3 (+) 6 (–) 1 Custom colors are available. Consult factory. M R 1 UP 3 (+) 6 (–) 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory. N T 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) 3 Gloss brow is on left side of E actuator and right side of F actuator. 4 Additional ratings available. See V-Series Switch Accessories page. P V 1 UP 1 (+) 4 (–) 5 Laser etched rocker only available with lens code Z & actuator colors black, 2 UP 3 (+) 6 (–) nickel or pewter. 6 Pewter and nickel colors only available with laser etched actuator. Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | V-Series Contura V Sealed Rocker Switches - Ordering Scheme 13 V 1 D A B T 0 B G P C 00 0 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Bracket Actuator Lens Color Legend Legend Actuator Series Circuit Rating Termination Illumination Lamp Lamp Orientation Lens Legend 6,7 LAMP (SAME CODING FOR BOTH SELECTIONS) 1 SERIES Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 12VDC C N H T 2 - - 5 2 - - 5 24VDC D P J V 3 - - 6 3 - - 6 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 1 A ON NONE OFF 8 FLUSH BRACKET COLOR , PANEL SEAL 2 B (ON) NONE OFF Black White Gray 3 C ON NONE (OFF) No Seal B W G 4 D ON NONE ON One Seal C Y H 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) 9 ACTUATOR SPECIAL CIRCUITS 0 No Actuator H* 2 & 3 2 & 3, 5 & 4 5 & 4 G Contura V G* 2 & 3, 5 & 6 2 & 3 OFF P Contura V, laser etched S* 2 & 3, 5 & 6 2 & 3 1 & 2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 E* 5 & 6 5 & 3 5 & 1 10 Lens *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. 0 - No Actuator Z - No Lens External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E may be used for SP OFF-ON-ON circuit. Clear White Amber Green Red Blue 1 6 8 G M T bar 2 7 C H N U bar/bar 4 3 RATING 3 8 D J P V oval 1 .4VA @ 28VDC Resistive 4 9 E K R W oval/bar B 15A 24V C 20A 18V 5 A F L S Y oval/oval D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. F 10A 14V, 6A 14VT (circuit G only) M .4VA/20A 12V N .4VA/15A 24V 1,3,3 11 ACTUATOR COLOR No Actuator 0 Black C Gray H Red S White Y Nickel D Pewter E 4 TERMINATION/BASE STYLE 8 term 10 Term Termination Jumper 1 2 .250 TAB (QC) no barriers No 2,6 12 ACTUATOR LENS OR BODY LEGENDS A B .250 TAB (QC) with barriers No J K .250 TAB (QC) no barriers Yes T2 to 5 11 ON 12 OFF 13 I 14 O 3 5 Solder Lug no barriers No OFF ON O I C D Solder Lug No 15 O O 16 O O 17 O I 18 I O 5 6 Wire Leads no barriers No F N N F E F Wire Leads No F F Note: Codes J & K for circuits H, G & M. For additional legend options & codes, visit us at www.carlingtech.com. 5 ILLUMINATION & SWITCH SEALING ORIENTATION OF ACTUATOR/LENS IN PANEL Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of 13 LEGEND ORIENTATION ORIENTATION 1 switch. Positive (+) and negative (-) symbols apply to LED lamps only 0 No legend (used with codes 11-18 in selection 12) Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals 1 Orientation 1 S 0 NONE – – 2 Orientation 2 A 1 1 INDEPENDENT 8 (+) 7 (–) 3 Orientation 3 B 2 1 DOWN 3 (+) 7 (–) 4 Orientation 4 4G13L C 3 2 UP 3 (+) 7 (–) 4G ORIENTATION 4 ORIENTATION 2 D 4 1 DOWN 3 (+) 7 (–) MC MA 4G 2 DOWN 1 (+) 7 (–) MC MA 3L E 5 1 UP 1 (+) 7 (–) 4G200 MA3MC 2 UP 3 (+) 7 (–) MA1MC ORIENTATION 3 F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 14 ACTUATOR LENS LEGEND 2 UP 3 (+) 7 (–) 00 No legend this location / no actuator H Z 2 INDEPENDENT 8 (+) 7 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch requires two U Y 1 INDEPENDENT 8 (+) 7 (–) legends. If the two legends consist of one lens and one body legend, lens legend must 2 INDEPENDENT 10 (+) 9 (–) be specified in selection 12; body legend specified in selection 14. For legend options & codes, visit us at www.carlingtech.com. SINGLE POLE SWITCHES ONLY J 8 1 DOWN 3 (+) 8 (–) 2 INDEPENDENT 6 (+) 7 (–) Notes: K W 1 INDEPENDENT 8 (+) 7 (–) Consult factory to verify horsepower rating for your particular circuit choice. 2 INDEPENDENT 6 (+) 7 (–) 1 Custom colors are available. Consult factory. DOUBLE POLE SWITCHES ONLY 2 White imprinting is standard on black actuators; Black imprinting is standard on L 9 1 DOWN 3 (+) 6 (–) white, red and gray actuators. Custom colors are available, consult factory. M R 1 UP 3 (+) 6 (–) 3 Laser Etched rocker only available with lens code Z & actuator colors black, nickel or pewter. N T 1 DOWN 3 (+) 6 (–) 2 DOWN 1 (+) 4 (–) 4 Additional ratings available. See V-Series Switch Accessories page. 5 Nickel and Pewter colors only available with laser etched actuator. P V 1 UP 1 (+) 4 (–) 6 Consult factory for laser etched lens callout. 2 UP 3 (+) 6 (–) Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | 14 V-Series Contura IV & V Locking Sealed Rocker Switches - Ordering Scheme V 1 D A S W 0 B J Z E 00 0 8 9 10 11 12 13 1 2 3 4 5 6 7 Series Circuit Rating Termination Illumination Lock Lamp Bracket Actuator Lens Function Legend Legend Orientation 1 SERIES 7 LAMP V Lamp above terminals 3 & 6 end of switch No lamp 0 Neon 1 125VAC 2 250VAC 3 Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 12VDC C N H T 2 - - 5 2 - - 5 24VDC D P J V 3 - - 6 3 - - 6 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 1 A ON NONE OFF 8 FLUSH BRACKET COLOR , PANEL SEAL 4 D ON NONE ON Black White Gray 6 J ON OFF ON No Seal B W G 7 K ON OFF (ON) One Seal C Y H 8 L (ON) OFF (ON) 9 N OFF NONE ON 9 HARD SURFACE ACTUATOR 4 CONTURA IV: 3 RATING Orientation Black Gray Red White 1 .4VA @ 28VDC Resistive Left J K L M B 15A 24V Right N P R S C 20A 18V D 20A 12V CONTURA V: Actuator orientation above terminals: 3,6 1,4 E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) Orientation Black Gray Red White F 10A 14V, 6A 14VT (circuit G only) U V W Y M .4VA/20A 12V N .4VA/15A 24V Actuator orientation above terminals: 3,6 1,4 4 TERMINATION/BASE STYLE 8 term 10 Term Termination Jumper 5 10 LENS 1 2 .250 TAB (QC) no barriers No Z - No Lens A B .250 TAB (QC) with barriers No Clear White Amber Green Red Blue J K .250 TAB (QC) no barriers Yes T2 to 5 A B C D E F bar lens 3 5 Solder Lug no barriers No C D Solder Lug No G H J K L M oval lens 5 6 Wire Leads no barriers No E F Wire Leads No Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. Note: Codes J & K for circuits H, G & M. 5 ILLUMINATION & SWITCH SEALING 1 11 ACTUATOR LOCK FUNCTION AND COLOR Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of 3 Lock Color Up Down Up & Down Center switch. Positive (+) and negative (-) symbols apply to LED lamps only Match Actuator A H R 1 Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals Black B J S 2 S 0 NONE – – White C K T 3 C 3 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) Red D L V 4 DOUBLE POLE SWITCHES ONLY Safety Orange E M W 5 M R 1 UP 3 (+) 6 (–) Gray F G N 6 2 12 ACTUATOR LENS OR BODY LEGEND 6 LOCK 00 - No Legend Lock above terminals 1 & 4 end of switch. 6 W low profile lock Y high profile lock 21 22 23 24 OFF ON O I Notes: 25 O 26 O 27 O 28 I Consult factory to verify horsepower rating for your particular circuit choice. F N 1 Custom colors are available. Consult factory. F 2 White imprinting is standard on black actuators; Black imprinting is standard on white, For additional legend options & codes, visit us at www.carlingtech.com. red and gray actuators. Custom colors are available, consult factory. 3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function. ORIENTATION OF ACTUATOR/LENS IN PANEL 4 Additional ratings available. See V-Series Switch Accessories page. ORIENTATION 1 13 LEGEND ORIENTATION 5 Located at T3-6 end of switch. 0 No legend 6 Contura V style only. 1 Orientation 1 2 Orientation 2 3 Orientation 3 4 Orientation 4 JHAY3-100 JHAY3-200 JHAY3-300 P P P P P P ORIENTATION 3 NHAY3-100 NHAY3-200 NHAY3-300 Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com ORIENTATION 4 ORIENTATION 2 2 Orientation | V-Series Contura VI WAVE Sealed Rocker Switches - Ordering Scheme 15 V 1 D B G N T B H A 7 C B AC 1 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Lens Color Insert Actuator Legend Actuator Color Lens Orientation Lens Legend 1 SERIES 7 LAMP V Lamp above terminals 3 & 6 end of switch No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 6VDC B M G S 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 1 - - 4 1 - - 4 12VDC C N H T 2 - - 5 2 - - 5 24VDC D P J V 3 - - 6 3 - - 6 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 1 A ON NONE OFF 8 FLUSH BRACKET COLOR , PANEL SEAL 2 B (ON) NONE OFF Black White Gray 3 C ON NONE (OFF) No Seal B W G 4 D ON NONE ON One Seal C Y H 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) 9 ACTUATOR SPECIAL CIRCUITS 0 No Actuator H High Insert L Low Insert H* 2 & 3 2 & 3, 5 & 4 5 & 4 G* 2 & 3, 5 & 6 2 & 3 OFF S* 2 & 3, 5 & 6 2 & 3 1 & 2 M* (2 & 3, 5 & 6) 2 & 3 OFF 4 R* (2 & 3, 5 & 6) 2 & 3 2 & 1 10,11 LENS E* 5 & 6 5 & 3 5 & 1 0 - No Actuator Z - No Lens *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. Clear White Amber Green Red Blue External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit – 7 C H N U Bar Lens Translucent E may be used for SP OFF-ON-ON circuit. 3 – D J P V Bar Lens Transparent 4 – E K R W Oval Lens Transparent 3 3 RATING – A F L S Y Oval Lens Translucent 1 .4VA @ 28VDC Resistive B 15A 24V Lens color for LEDs must be clear, white, or match color of LED. C 20A 18V Green or blue lenses are not recommended with Neon lamps. D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) 12 ACTUATOR COLOR M .4VA/20A 12V C Black H Gray S Red Y White N .4VA/15A 24V 13 INSERT COLOR N Bright Nickel Plated 4 TERMINATION/BASE STYLE B Black S Satin Chrome Plated 8 term 10 Term Termination Jumper C Bright Chrome Plated T Satin Nickel Plated 1 2 .250 TAB (QC) no barriers No A B .250 TAB (QC) with barriers No D Satin Chrome Painted W White J K .250 TAB (QC) no barriers Yes T2 to 5 3 5 Solder Lug no barriers No 2 C D Solder Lug No 14 ACTUATOR LENS OR BODY LEGENDS 5 6 Wire Leads no barriers No 00 - No Legend this location/No actuator E F Wire Leads No 11 ON 12 OFF 13 I 14 O Note: Codes J & K for circuits H, G & M. OFF ON O I 15 O O 16 O O 17 O I 18 I O F N N F 5 ILLUMINATION & SWITCH SEALING Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of F F switch. Positive (+) and negative (-) symbols apply to LED lamps only For additional legend options & codes, visit us at www.carlingtech.com. Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – Orientation 1 A 1 1 INDEPENDENT 8 (+) 7 (–) 15 LEGEND ORIENTATION B 2 1 DOWN 3 (+) 7 (–) 0 No legend (used with codes 11-18 in selection 12) C 3 2 UP 3 (+) 7 (–) 1 Orientation 1 D 4 1 DOWN 3 (+) 7 (–) 2 Orientation 2 2 DOWN 1 (+) 7 (–) 3 Orientation 3 E 5 1 UP 1 (+) 7 (–) 4 Orientation 4 2 UP 3 (+) 7 (–) VTHAACN-MC1MC VTHA7CN-3M100 VTHWZCB-45146 F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) Orientation 3 VTLSZSC-70100 VTLLFHC-A813H VTLDECC-001MG H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) 16 ACTUATOR LENS LEGEND SINGLE POLE SWITCHES ONLY 00 No legend this location / no actuator J 8 1 DOWN 3 (+) 8 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch requires two 2 INDEPENDENT 6 (+) 7 (–) legends. If the two legends consist of one lens and one body legend, lens legend must K W 1 INDEPENDENT 8 (+) 7 (–) be specified in selection 12; body legend specified in selection 14. 2 INDEPENDENT 6 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. DOUBLE POLE SWITCHES ONLY L 9 1 DOWN 3 (+) 6 (–) Notes: M R 1 UP 3 (+) 6 (–) Consult factory to verify horsepower rating for your particular circuit choice. N T 1 DOWN 3 (+) 6 (–) 1 Custom colors are available. Consult factory. 2 DOWN 1 (+) 4 (–) 2 White imprinting is standard on black actuators. Black imprinting is standard on white, P V 1 UP 1 (+) 4 (–) red and gray actuators. Custom colors are available, consult factory. 2 UP 3 (+) 6 (–) 3 Additional ratings available. See V-Series Switch Accessories page. Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com 4 Orientation ORIENTATION 4 ORIENTATION 2 | 16 V-Series Contura VII Sealed Rocker Switches - Ordering Scheme V 1 D A B T 0 B Z R C 00 0 00 8 9 10 11 12 13 14 1 2 3 4 5 6 7 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Color Legend Legend Actuator Orientation Lens Legend 1 SERIES 6,7 LAMP (same coding for both selections) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S 1 - - 4 1 - - 4 12VDC C N H T 2 - - 5 2 - - 5 24VDC D P J V 3 - - 6 3 - - 6 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 8 FLUSH BRACKET COLOR , PANEL SEAL 1 A ON NONE OFF 2 B (ON) NONE OFF Black White Gray 3 C ON NONE (OFF) No Seal B W G 4 D ON NONE ON One Seal C Y H 5 F ON NONE (ON) 6 J ON OFF ON ACTUATOR 7 K ON OFF (ON) ORENTATION 9 ACTUATOR 8 L (ON) OFF (ON) ABOVE TERMINALS SPECIAL CIRCUITS 0 No Actuator 3,6 1,4 H* 2 & 3 2 & 3, 5 & 4 5 & 4 Z Contura VII G* 2 & 3, 5 & 6 2 & 3 OFF STANDARD S* 2 & 3, 5 & 6 2 & 3 1 & 2 M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 E* 5 & 6 5 & 3 5 & 1 10 LENS *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. Lens color for LEDs must be clear, white, or match color of LED. External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit Green or blue lenses are not recommended with Neon lamps. E may be used for SP OFF-ON-ON circuit. 0 - No Actuator Z - No Lens White Amber Green Red Blue Lens style & location 4 3 RATING 6 B G M T 1 .4VA @ 28VDC Resistive 7 C H N U B 15A 24V C 20A 18V 8 D J P V D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 9 E K R W F 10A 14V, 6A 14VT (circuit G only) A F L S Y M .4VA/20A 12V N .4VA/15A 24V 1 2 3 4 5 4 TERMINATION/BASE STYLE 1 11 ACTUATOR COLOR/THUMB PRINT COLOR 8 term 10 Term Termination Jumper 1 2 .250 TAB (QC) no barriers No O N/A - No Actuator C Black/Black H Grey/Black S Red/Black A B .250 TAB (QC) with barriers No J K .250 TAB (QC) no barriers Yes T2 to 5 Y White/Black 3 5 Solder Lug no barriers No C D Solder Lug No 2 5 6 Wire Leads no barriers No 14 ACTUATOR LENS OR BODY LEGENDS E F Wire Leads No 11 ON 12 OFF 13 I 14 O Note: Codes J & K for circuits H, G & M. OFF ON O I 15 O O 16 O O 17 O I 18 I O 5 ILLUMINATION & SWITCH SEALING F N N F Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of F F switch. Positive (+) and negative (-) symbols apply to LED lamps only For additional legend options & codes, visit us at www.carlingtech.com. Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals S 0 NONE – – ORIENTATION 1 A 1 1 INDEPENDENT 8 (+) 7 (–) 13 LEGEND ORIENTATION B 2 1 DOWN 3 (+) 7 (–) 0 No legend (used with codes 11-18 in selection 12) C 3 2 UP 3 (+) 7 (–) 1 Orientation 1 D 4 1 DOWN 3 (+) 7 (–) 2 Orientation 2 2 DOWN 1 (+) 7 (–) 3 Orientation 3 E 5 1 UP 1 (+) 7 (–) 4 Orientation 4 2 UP 3 (+) 7 (–) F 6 1 INDEPENDENT 8 (+) 7 (–) AA 2 UP 3 (+) 6 (–) G 7 1 INDEPENDENT 8 (+) 7 (–) 46 46 AA 2 UP 3 (+) 7 (–) ORIENTATION 3 3AA-146 3AA-246 H Z 2 INDEPENDENT 8 (+) 7 (–) U Y 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) 14 ACTUATOR LENS LEGEND SINGLE POLE SWITCHES ONLY 00 No legend this location / no actuator J 8 1 DOWN 3 (+) 8 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch requires two 2 INDEPENDENT 6 (+) 7 (–) legends. If the two legends consist of one lens and one body legend, lens legend must K W 1 INDEPENDENT 8 (+) 7 (–) be specified in selection 12; body legend specified in selection 14. 2 INDEPENDENT 6 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. DOUBLE POLE SWITCHES ONLY L 9 1 DOWN 3 (+) 6 (–) Notes: M R 1 UP 3 (+) 6 (–) Consult factory to verify horsepower rating for your particular circuit choice. N T 1 DOWN 3 (+) 6 (–) 1 Custom colors are available. Consult factory. 2 DOWN 1 (+) 4 (–) 2 White imprinting is standard on black actuators. Black imprinting is standard on white, P V 1 UP 1 (+) 4 (–) red and gray actuators. Custom colors are available, consult factory. 2 UP 3 (+) 6 (–) 3 Additional ratings available. See V-Series Switch Accessories page. 4 Legends available for lighted oval lens version only Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com ORIENTATION 4 ORIENTATION 1 ORIENTATION 2 ORIENTATION 3 ORIENTATION 4 ORIENTATION 1 ORIENTATION 2 ORIENTATION 3 ORIENTATION 2 | V-Series Contura X, XI & XII Sealed Rocker Switches - Ordering Scheme 17 V 1 D A B 6 0 1 6 P Z 00 0 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Lens Legend Legend Actuator Orientation Lens Legend 6,7 LAMP (same coding for both selections) 1 SERIES Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC 2 CIRCUIT Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V Terminal Connections as viewed ( ) - momentary LED* superbright superbright from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. Red Amber Green Red 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 2VDC A L F R 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S 1 - - 4 1 - - 4 12VDC C N H T 2 - - 5 2 - - 5 24VDC D P J V 3 - - 6 3 - - 6 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF 1 8 BRACKET COLOR , PANEL SEAL (EXTERNAL FOAM GASKET) 2 B (ON) NONE OFF X & XI w/Flush Bracket X, XI, XII w/Raised Bracket 3 C ON NONE (OFF) # of gaskets 0 1 2 0 1 4 D ON NONE ON 5 F ON NONE (ON) Black B C D 1 4 6 J ON OFF ON White W Y Z 2 5 7 K ON OFF (ON) Gray G H J 3 6 8 L (ON) OFF (ON) SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5 & 4 9 ACTUATOR G* 2 & 3, 5 & 6 2 & 3 OFF No Actuator 0 S* 2 & 3, 5 & 6 2 & 3 1 & 2 Black Gray White Red M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 Contura X 1 2 3 4 E* 5 & 6 5 & 3 5 & 1 Contura XI 6 7 8 9 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. Contura XII J K N M External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit 1,4 3,6 Actuator orientation above terminals: E may be used for SP OFF-ON-ON circuit. 4 1,4 10 LENS - ABOVE LAMP #1 TERMINALS 3 RATING 3,6 1 .4VA @ 28VDC Resistive 11 LENS - ABOVE LAMP #2 TERMINALS B 15A 24V 0 - No Actuator Z - No Lens C 20A 18V Clear White Amber Green Red Blue Lens Style D 20A 12V 3 8 D J P V Bar E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) F 10A 14V, 6A 14VT (circuit G only) 4 9 E K R W One piece Square M .4VA/20A 12V 5 A F L S Y Two piece Square* N .4VA/15A 24V (w/ clear top protective lens) 2 7 C H N U Two piece Square* 4 TERMINATION/BASE STYLE (w/ smoke top protective lens) 8 term 10 Term Termination Jumper 1 6 B G M T Two piece Square* 1 2 .250 TAB (QC) no barriers No (w/ white top protective lens) A B .250 TAB (QC) with barriers No J K .250 TAB (QC) no barriers Yes T2 to 5 * All bottom lenses are molded of opaque material. Consult factory for other lens colors. 3 5 Solder Lug no barriers No Lens color for LEDs must be clear, white, or match color of LED. C D Solder Lug No Green or blue lenses are not recommended with Neon lamps. 5 6 Wire Leads no barriers No E F Wire Leads No 2 Note: Codes J & K for circuits H, G & M. 12 ACTUATOR LENS OR BODY LEGEND 00 - No Legend this location/No actuator 11 ON 12 OFF 13 I 14 O 5 ILLUMINATION & SWITCH SEALING OFF ON O I Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of switch. Positive (+) and negative (-) symbols apply to LED lamps only 15 O O 16 O O 17 O I 18 I O Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals F N N F S 0 NONE – – F F A 1 1 INDEPENDENT 8 (+) 7 (–) 21 22 23 24 B 2 1 DOWN 3 (+) 7 (–) C 3 2 UP 3 (+) 7 (–) OFF ON O I D 4 1 DOWN 3 (+) 7 (–) 25 O 26 O 27 O 28 I 2 DOWN 1 (+) 7 (–) F N E 5 1 UP 1 (+) 7 (–) F 2 UP 3 (+) 7 (–) For additional legend options & codes, visit us at www.carlingtech.com. F 6 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 6 (–) ORIENTATION OF G 7 1 INDEPENDENT 8 (+) 7 (–) ACTUATOR/LENS IN PANEL 3 13 LEGEND ORIENTATION ORIENTATION 1 2 UP 3 (+) 7 (–) 0 No legend (used with codes 11-18 in selection 12) H Z 2 INDEPENDENT 8 (+) 7 (–) 1 Orientation 1 U Y 1 INDEPENDENT 8 (+) 7 (–) 2 Orientation 2 2 INDEPENDENT 10 (+) 9 (–) 3 Orientation 3 SINGLE POLE SWITCHES ONLY 4 Orientation 4 6ZZ3G-100 J 8 1 DOWN 3 (+) 8 (–) 6FFMA-4MC MA 70 2 INDEPENDENT 6 (+) 7 (–) 3G G3 K W 1 INDEPENDENT 8 (+) 7 (–) A7 MC MA MC 2 INDEPENDENT 6 (+) 7 (–) ORIENTATION 3 6ZZ3G-1A7 6FFMA-3MC 6FZ70-100 DOUBLE POLE SWITCHES ONLY L 9 1 DOWN 3 (+) 6 (–) M R 1 UP 3 (+) 6 (–) 14 ACTUATOR LENS LEGEND N T 1 DOWN 3 (+) 6 (–) 00 No legend this location / no actuator 2 DOWN 1 (+) 4 (–) (used with codes 11-18 in selection 12) Selection 14 required when switch requires two P V 1 UP 1 (+) 4 (–) legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. 2 UP 3 (+) 6 (–) For legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, red & gray actuators. Custom colors are available, consult factory. 3 With 2 square lenses, use sel. 12 for lens above lamp 1, & selection 14 for lens above lamp 2. 4 Additional ratings available. See V-Series Switch Accessories page. 5 Not available with Contura XI rockers. Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com ORIENTATION 4 | 18 V-Series Contura X Locking Sealed Rocker Switches - Ordering Scheme V 1 D A S W 0 1 1 P B 00 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Series Circuit Rating Termination Illumination Lock Lamp Bracket Actuator Lens Function Legend Legend Orientation 1 SERIES 6,7 LAMP (same coding for both selections) Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6 V No lamp 0 Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V 2 CIRCUIT LED* superbright superbright Terminal Connections as viewed ( ) - momentary Red Amber Green Red from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 2VDC A L F R 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 6VDC B M G S 1 - - 4 1 - - 4 12VDC C N H T 2 - - 5 2 - - 5 24VDC D P J V 3 - - 6 3 - - 6 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 10 - - 9 Position: 1 2 3 SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 8 FLUSH BRACKET COLOR , PANEL SEAL 1 A ON NONE OFF 4 D ON NONE ON Black White Gray 6 J ON OFF ON No Gasket 1 2 3 9 N OFF NONE ON One Gasket 4 5 6 SPECIAL CIRCUITS H* 2 & 3 2 & 3, 5 & 4 5 & 4 G* 2 & 3, 5 & 6 2 & 3 OFF 9 HARD SURFACE ACTUATOR S* 2 & 3, 5 & 6 2 & 3 1 & 2 E* 5 & 6 5 & 3 5 & 1 *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. Contura X Black Grey Red White External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit 1 2 3 4 E may be used for SP OFF-ON-ON circuit. Actuator orientation above terminals: 3,6 1,4 4 3 RATING 5 1 .4VA @ 28VDC Resistive 10 LENS - ABOVE LAMP #2 TERMINALS B 15A 24V Z - No Lens C 20A 18V Clear White Amber Green Red Blue Lens Style D 20A 12V 3 8 D J P V Bar E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) 4 9 E K R W One piece Square F 10A 14V, 6A 14VT (circuit G only) 5 A F L S Y Two piece Square* M .4VA/20A 12V N .4VA/15A 24V (w/ clear top protective lens) 2 7 C H N U Two piece Square* (w/ smoke top protective lens) 4 TERMINATION/BASE STYLE 1 6 B G M T Two piece Square* 8 term 10 Term Termination Jumper (w/ white top protective lens) 1 2 .250 TAB (QC) no barriers No A B .250 TAB (QC) with barriers No * All bottom lenses are molded of opaque material. Consult factory for other lens colors. J K .250 TAB (QC) no barriers Yes T2 to 5 Lens color for LEDs must be clear, white, or match color of LED. 3 5 Solder Lug no barriers No Green or blue lenses are not recommended with Neon lamps. C D Solder Lug No 5 6 Wire Leads no barriers No E F Wire Leads No 3 Note: Codes J & K for circuits H, G & M. 11 ACTUATOR LOCK FUNCTION AND COLOR Lock Color Up Down Up & Down Match Actuator A H R 5 ILLUMINATION & SWITCH SEALING Black B J S Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of White C K T switch. Positive (+) and negative (-) symbols apply to LED lamps only Red D L V Sealed Unsealed Lamps Illumination Type Lamp wired to Terminals Gray E M W S 0 NONE – – Safety Orange F N Y C 3 2 UP 3 (+) 7 (–) H Z 2 INDEPENDENT 8 (+) 7 (–) DOUBLE POLE SWITCHES ONLY 2 M R 1 UP 3 (+) 6 (–) 12 ACTUATOR LENS OR BODY LEGEND 00 - No Legend 21 22 23 24 6 LOCK OFF ON O I Lock above terminals 1 & 4 end of switch. 25 O 26 O 27 O 28 I W lock F N F For additional legend options & codes, visit us at www.carlingtech.com. Notes: Consult factory to verify horsepower rating for your particular circuit choice. 1 Custom colors are available. Consult factory. 2 White imprinting is standard on black actuators; Black imprinting is standard on white, Orientation 1 3 13 LEGEND ORIENTATION red and gray actuators; Custom colors are available, consult factory. 0 No legend (used with codes 11-18 in selection 12) 3 Located over T1-4 end of switch. 1 Orientation 1 4 Additional ratings available. See V-Series Switch Accessories page. 2 Orientation 2 5 Located over T3-6 end of switch. 3 Orientation 3 4 Orientation 4 Orientation Orientation 4 1PM4F-1 2 45 4F MC 18K45-2 Orientation 3 13DMC-1 Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | V-Series Contura XIV Sealed Rocker Switches - Ordering Scheme 19 V 1 D B B C 0 B FA P C AB 1 00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Series Circuit Rating Termination Illumination Lamp Lamp Bracket Actuator Lens Actuator Legend Legend Actuator, Color Orientation Lens Legends 1 SERIES 6 & 7 LAMP No lamp 0 V Neon 1 125VAC 2 250VAC Incandescent 4 3V 5 6V 6 12V 7 18V 8 24V LED* superbright superbright 2 CIRCUIT Red Amber Green Red Terminal Connections as viewed ( ) - momentary 2VDC A L F R from bottom of switch: SP - single pole - uses terminals 1, 2 & 3. 6VDC B M G S 8 terminal 10 terminal DP - double pole uses terminals 1, 2, 3, 4, 5 & 6. 8 - - 7 8 - - 7 Terminals 7, 8, 9 & 10 for lamp circuit only. 12VDC C N H T 1 - - 4 1 - - 4 24VDC D P J V 2 - - 5 2 - - 5 * Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma. 3 - - 6 3 - - 6 10 - - 9 Position: 1 2 3 8 BRACKET COLOR & PANEL SEAL SP DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 1 A ON NONE OFF Color No Gasket 1 Gasket 2 Gasket 2 B (ON) NONE OFF Black B C D 3 C ON NONE (OFF) Gray G H J 4 D ON NONE ON White W Y Z 5 F ON NONE (ON) 6 J ON OFF ON 7 K ON OFF (ON) 8 L (ON) OFF (ON) 9 ACTUATOR STYLE SPECIAL CIRCUITS 0 No Actuator - Furnished separately H* 2 & 3 2 & 3, 5 & 4 5 & 4 FA Contura XIV G* 2 & 3, 5 & 6 2 & 3 OFF FB Contura XIV - Laser Etched M* (2 & 3, 5 & 6) 2 & 3 OFF R* (2 & 3, 5 & 6) 2 & 3 2 & 1 E* 5 & 6 5 & 3 5 & 1 S* 2 & 3, 5 & 6 2 & 3 1 & 2 10 LENS COLOR / STYLE *Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4. 0 - No Actuator Z - No Lens External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit Clear White Amber Green Red Blue E may be used for SP OFF-ON-ON circuit. 1 6 B G M T 2 7 C H N U 3 3 RATING 3 8 D J P V 1 .4VA @ 28VDC Resistive 4 9 E K R W B 15A 24V 5 A F L S Y PAD Printed C 20A 18V 5 A N/A N/A N/A N/A Laser-Etched D 20A 12V E 20A 14V, 10A 14VT (circuit 1, 4 , A & D only) Lens color for LEDs must be clear, white, or match color of LED. F 10A 14V, 6A 14VT (circuit G only) Green or blue lenses are not recommended with Neon lamps. 4 TERMINATION / BASE STYLE 1 11 ACTUATOR COLOR 8 term 10 Term Termination Jumper O N/A - No Actuator 1 2 .250 TAB (QC) no barriers No C Black A B .250 TAB (QC) with barriers No S Red J K .250 TAB (QC) no barriers Yes T2 to 5 Y White 3 4 Solder Lug no barriers No C D Solder Lug No 5 6 Wire Leads no barriers No 2 E F Wire Leads No 12 ACTUATOR LENS or BODY LEGEND Note: Codes J & K for circuits H, G & M. 00 - No Legend this location/No actuator 11 ON 12 OFF 13 I 14 O OFF ON O I 5 ILLUMINATION Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of 15 O O 16 O O 17 O I 18 I O switch. Positive (+) and negative (-) symbols apply to LED lamps only F N N F Lamps Illumination Type Lamp wired to Terminals F F S NONE – – A 1 INDEPENDENT 8 (+) 7 (–) B 1 DOWN 3 (+) 7 (–) 13 LEGEND ORIENTATION C 2 UP 3 (+) 7 (–) 0 No legend D 1 DOWN 3 (+) 7 (–) 1 Orientation 1 2 DOWN 1 (+) 7 (–) 2 Orientation 2 E 1 UP 1 (+) 7 (–) 3 Orientation 3 2 UP 3 (+) 7 (–) 4 Orientation 4 F 1 INDEPENDENT 8 (+) 7 (–) 1 24 3 2 UP 3 (+) 6 (–) G 1 INDEPENDENT 8 (+) 7 (–) 2 UP 3 (+) 7 (–) 14 ACTUATOR / LENS LEGEND H 2 INDEPENDENT 8 (+) 7 (–) 00 No legend this location / no actuator SINGLE POLE SWITCHES ONLY (used with codes 11-18 in selection 12) Selection 14 required when switch requires two J 1 DOWN 3 (+) 8 (–) legends. If the two legends consist of one lens and one body legend, lens legend must be specified in selection 12; body legend specified in selection 14. 2 INDEPENDENT 6 (+) 7 (–) For legend options & codes, visit us at www.carlingtech.com. K 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 6 (+) 7 (–) DOUBLE POLE SWITCHES ONLY Notes: L 1 DOWN 3 (+) 6 (–) Consult factory to verify horsepower rating for your particular circuit choice. M 1 UP 3 (+) 6 (–) 1 Custom colors are available. Consult factory. N 1 DOWN 3 (+) 6 (–) 2 White imprinting is standard on black actuators; Black imprinting is standard on white, 2 DOWN 1 (+) 4 (–) red and gray actuators. P 1 UP 1 (+) 4 (–) 3 Additional ratings available. See V-Series Switch Accessories page. 2 UP 3 (+) 6 (–) U 1 INDEPENDENT 8 (+) 7 (–) 2 INDEPENDENT 10 (+) 9 (–) Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | 20 V-Series Contura Sealed Rocker Switch Actuators Separately Reduce inventory levels and cost by stocking actuators and base switches separately. Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes. Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes. Contura VI Actuator with lenses and inserts only: VV with code selections 9-16 Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes. Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes. Panel Seal: VPS Contura X & XI actuators without lenses separately: Contura XII actuators without lenses separately: VVR 6 1 00 1 VVP J 1 Z 21 1 00 1 2 3 4 5 1 2 3 4 5 6 7 Actuator Separately Actuator Lens Actuator Legend Actuator Style & Lens Lens Legend Legend Legend Style/Color Opening Legend Orientation Color Opening Opening Orientation 1 CONTURA X & XI ACTUATOR SEPARATELY 1 CONTURA XII ACTUATOR SEPARATELY VVP VVP 2 ACTUATOR STYLE & COLOR 2 ACTUATOR STYLE & COLOR Black Gray White Red J Black K Gray N White M Red Contura X 1 2 3 4 Contura XI 6 7 8 9 3,4 LENS OPENING FOR Z No lens 1 Bar lens 2 Square lens 1 3 LENS OPENING FOR 1 One bar lens 5 square lens on top/ 2 One bar lenses bar lens on bottom 2 5, 7 LENS OR BODY LEGEND 3 One square lens (Contura X only) 4 two square lens 00 - No Legend 21 22 23 24 OFF ON O I 25 O 26 O 27 O 28 I 4 ACTUATOR LENS OR BODY LEGEND F N 00 - No Legend this location F 11 ON 12 OFF 13 I 14 O For additional legend options & codes, visit us at www.carlingtech.com. OFF ON O I 15 O O 16 O O 17 O I 18 I O ORIENTATION OF 3 ACTUATOR/LENS IN PANEL 6 LEGEND ORIENTATION F N N F ORIENTATION 1 0 No legend F F For additional legend options & codes, visit us at www.carlingtech.com. 1 Orientation 1 ORIENTATION 2 2 Orientation 2 ORIENTATION OF ACTUATOR/LENS IN PANEL 1 5 LEGEND ORIENTATION ORIENTATION 1 0 No legend Contura X, XI & XII actuator lens assembly separately: 1 Orientation 1 2 Orientation 2 3 Orientation 3 ORIENTATION 4 ORIENTATION 2 4 Orientation 4 VVL 2 1 00 0 1 2 3 4 5 Lens Separately Lens Lens Legend Legend Style Color Orientation ORIENTATION 3 1 CONTURA X, XI & XII LENS SEPARATELY VVL Contura X, XI & XII top piece of 2-piece lens separately: 3 2 LENS STYLE 5 1 Bar lens 2 One Piece Square lens 3 Bottom of Two-Piece Square lens 1 TOP OF LENS SEPARATELY VVT VVT 1 3 TRANSLUCENT LENS COLOR 4 4 1 Clear 2 White 3 Amber 4 Green 5 Red 6 Blue 1 2 2 COLOR Lens Separately Color 1 Clear 2 Smoke 3 White 2 4 LENS OR BODY LEGEND 00 - No Legend 21 22 23 24 Contura X, XI & XII actuator lens assembly: OFF ON O I 25 O 26 O 27 O 28 I F N actuator stem top lens F two piece For additional legend options & codes, visit us at www.carlingtech.com. } lens assembly posts mount toward actuator stem bottom lens ORIENTATION OF ACTUATOR/LENS IN PANEL 1 piece lens/bar lens are positioned the same as bottom lens for assembly, 3 5 LEGEND ORIENTATION ORIENTATION 1 minus the top lens. Lenses snap in from bottom. 0 No legend 1 Orientation 1 Notes: 2 Orientation 2 1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2 3 Orientation 3 ORIENTATION 4 ORIENTATION 2 must be chosen. 4 Orientation 4 2 Center of actuator marking not available for Contura XII. 3 Legend is not available for bar style lens. 4 Not recommended with neon lamps. 5 Must also order top piece of 2 piece square lens separately. ORIENTATION 3 Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | V-Series Contura Sealed Rocker Switch Accessories 21 Easily integrate Contura products into your system, with Contura Accessories Q.C. SELECTION GUIDE Contura Connectors WIRE PART NO RANGE COMPANY ORIEN- Q.C. SELECTION GUIDE TIN SERIES PLAIN 2 TATION AWG MM PLATED BRASS WIRE (REF) PART NO BRASS RANGE COMPANY 02965580 12 3.0 ORIEN- TIN SERIES PLAIN 2 TATION 02965471 12010601 (2)16-14 (2)1.0-2.0 AWG MM PLATED Q.C. SELECTION GUIDE Q.C. SELECTION GUIDE Q.C. SELECTION GUIDE BRASS PACKARD (REF) BRASS 02965470 16-14 1.0-2.0 B 58 SERIES WIRE WIRE WIRE PART NO PART NO PART NO 02965580 12 3.0 02965469 06288318 RANGE 20-18 RANGE .5-.8 RANGE COMPANY COMPANY COMPANY ORIEN- ORIEN- ORIEN- 02965471 12010601 (2)16-14 (2)1.0-2.0 TIN TIN TIN SERIES SERIES PLAIN SERIES PLAIN 12084590 PLAIN 102 TATION5.0 2 TATION 2 TATION AWG MM AWG MM AWG MM PACKARD PLATED PLATED PLATED Q.C. SELECTION GUIDE BRASS 02965470 BRASS BRASS 16-14 1.0-2.0 B TANG 12052224 (REF) 12 (REF) 3.0 (REF) 58 SERIES BRASS BRASS BRASS WIRE 02965469 06288318 20-18 .5-.8 02965580 02965580 1202965580 3.012 3.012 3.0 PART NO 12015870 16-14 1.0-2.0 RANGE PACKARD COMP 02965471 ANY 12010601 02965471 (2)16-14 12010601 02965471 (2)1.0-2.0 (2)16-14 12010601 (2)1.0-2.0 (2)16-14 ORIEN- (2)1.0-2.0 12084590 10 5.0 Q.C. SELECTION GUIDE METRI-PACK 12020035 TIN (2)22-18 (2).5-.8 A PACKARD SERIES PACKARD PLAIN PACKARD 2 TATION 02965470 02965470 16-14 02965470 1.0-2.0 16-14 B 1.0-2.0 16-14 B 1.0-2.0 B TANG PLATED AWG MM 58 SERIES 630 SERIES58 SERIES 58 SERIES 12052224 12 3.0 BRASS WIRE 12015832 12015869 20-18 .5-.8 BRASS (REF) 02965469 06288318 02965469 PART NO20-18 06288318 02965469 .5-.8 20-18 06288318 .5-.8 20-18 .5-.8 RANGE 12015870 16-14 1.0-2.0 PACKARD COMPANY 02965580 12 3.0 ORIEN- 12052222 20-22 .35-.5 12084590 12084590 10 5.012084590 10 5.010 5.0 TIN TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT 2 METRI-PACK SERIES 02965471 PLAIN 12020035 12010601 (2)22-18 (2)16-14 (2)1.0-2.0 (2).5-.8 TATION A TANG TANG TANG 12052224 PL 12052224 1 A2 TED AWG 3.012052224 12 MM 3.012 3.0 16-12 1.3-3 PACKARD BRASS 630 SERIES 02965470 16-14 1.0-2.0 (REF) B SYMBOL 60253-1 60253-2 BRASS 58 SERIES 12015832 12015870 1201586916-14 12015870 20-18 1.0-2.0 16-14 12015870 .5-.81.0-2.0 16-14 1.0-2.0 AMP PACKARD PACKARD PACKARD (2) 16 (2) 1.3 02965469 0296558006288318 20-1812 .5-.8 3.0 250 SERIES METRI-PACK METRI-PACK 12020035 METRI- 12052222 PACK (2)22-18 12020035 20-22 (2).5-.8 (2)22-18 12020035 .35-.5 A (2).5-.8 (2)22-18 A (2).5-.8 A B TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT 630 SERIES 630 SERIES 630 SERIES 0296547112084590 12010601 10(2)16-14 5.0 (2)1.0-2.0 FASTIN-FASTON 42100-1 42100-2 18-14 .8-2 12015832 12015869 12015832 20-18 12015869 12015832 .5-.8 20-18 12015869 .5-.8 20-18 .5-.8 PACKARD TANG 16-12 1.3-3 0296547012052224 12 16-14 3.01.0-2.0 B 58 SERIES SYMBOL 60253-1 60253-2 AMP 60295-1 12052222 60295-2 20-22 12052222 .35-.5 22-18 20-22 12052222 .35-.5 20-22 .3-.9 .35-.5 12015870 16-14 1.0-2.0 TANG SYMBOL =TANG SYMBO SHOWS ORIEN L =TANG SYMBO TA SHOWS ORIEN TION OF L = TANG IN SLOT TA SHOWS ORIEN TION OF TANG IN SLOT TATION OF TANG IN SLOT 02965469 06288318 (2) 16 20-18 (2) 1.3 .5-.8 PACKARD 250 SERIES 16-12 1.3-3 16-12 1.3-3 16-12 1.3-3 B METRI-PACK 12020035 (2)22-18 (2).5-.8 A SYMBOL SYMBOL SYMBOL 60253-1 60253-2 60253-1 12084590 60253-2 60253-1 10 60253-2 5.0 FASTIN- NOTE: AMP FAS Consult Delphi Packard and/or TON AMP 42100-1 AMP 42100-2 Amp on actual part numbers and availabilit 18-14 .8-2 y. 630 SERIES (2) 16 (2) 1.3 (2) 16 (2) 1.3 (2) 16 (2) 1.3 TANG 12015832 12015869 20-18 .5-.8 250 SERIES 250 SERIES 250 SERIES 12052224 12 3.0 AMP is a registered trademark of AMP Inc. Harrisburg, PA B B B FASTIN-FASTONFASTIN- 42100-1 60295-1 FASTON FASTIN- 42100-2 42100-1 60295-2 FASTON 18-14 42100-2 42100-1 22-18.8-2 18-14 42100-2 .3-.9 .8-2 18-14 .8-2 12052222 12015870 20-22 16-14 .35-.5 1.0-2.0 Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems TANG SYMBO Warren, Ohio L = SHOWS ORIENTATION OF TANG IN SLOT PACKARD 60295-1 60295-2 60295-1 22-18 60295-2 60295-1 16-12.3-.9 22-18 60295-2 1.3-3 .3-.9 22-18 .3-.9 METRI-PACK 12020035 (2)22-18 (2).5-.8 A 60253-1 60253-2 SYMBOL NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability. AMP 630 SERIES 12015832 12015869 (2) 16 20-18 (2) 1.3 .5-.8 250 SERIES .820[20.83] NOTE: AM Consult Delphi Packard and/or P is a registered trademark of NOTE: Consult Delphi Packard and/or NOTE: Amp on actual part numbers and availabilit Consult Delphi Packard and/or AMP Inc. Harrisburg, Amp on actual part numbers and availabilit PA Amp on actual part numbers and availabilit y. y. y. B FASTIN-FAST.820[20.83] ON 42100-1 42100-2 18-14 .8-2 AMP is a registered trademark of AMP is a registered trademark of AM AM P Inc. Harrisburg, P is a registered trademark of 12052222 AMP P Inc. Harrisburg, A 20-22 AMP PA Inc. Harrisburg, .35-.5 PA Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio TANG SYMBOL = SHOWS ORIENTATION OF TANG IN SLOT Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio Warren, Ohio Warren, Ohio 60295-1 60295-2 22-18 .3-.9 16-12 1.3-3 60253-1 60253-2 SYMBOL AMP (2) 16 (2) 1.3 .820[20.83] NOTE: Consult Delphi Packard and/or 250 SERIES Amp on actual part numbers and availabilit .820[20.83] y. .820[20.83] .820[20.83] B .820[20.83] .820[20.83] AMP is a registered trademark of .820[20.83] AMP.820[20.83] Inc. Harrisburg, PA FASTIN-FASTON 42100-1 42100-2 18-14 .8-2 Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio 60295-1 60295-2 22-18 .3-.9 .770[19.56] .820[20.83] NOTE: Consult Delphi Packard and/or Amp on actual part numbers and availability. .820[20.83] AMP is a registered trademark of AMP Inc. Harrisburg, PA .770[19.56] .770[19.56] .770[19.56] .770[19.56] Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio .920[23.37] .920[23.37] 1.170[29.72] .820[20.83] .820[20.83] .770[19.56] .920[23.37] .920[23.37] .920[23.37] .920[23.37] .920[23.37] .920[23.37] 1.170[29.72] 1.170[29.72] 1.170[29.72] A A A A .920[23.37] .920[23.37] 1.170[29.72] PACKARD 630 PACKARD 630 A A A A A A VC2 A A A A A A PACKARD 630 PACKARD 630 .920[23.37] .920[23.37] 1.170[29.72] VC1 VC1 PACKARD 630 VC2 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 VC2 VC2 VC2 .770[19.56] PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 PACKARD 630 VC1 VC1 VC1 VC1 VC1 VC1 VC2 VC2 VC2 .950[24.13] B B .950[24.13] .950[24.13] .950[24.13] A B B B B A B B A A A A A A PACKARD 630 B PACKARD 630 B AMP, PACKARD 58 AMP, PACKARD 58 AMP VC2 AMP B B B B B B PACKARD 630 AMP, PACKARD 58 AMP, PACKARD 58 AMP, PACKARD 58 PACKARD 630 AMP, PACKARD 58 AMP, PACKARD 58 AMP AMP, PACKARD 58 AMP AMP AMP AMP AMP PACKARD 630 PACKARD 630 VC2 VC1 PACKARD 630 PACKARD 630 VC1 VC2 AMP, PACKARD 58 AMP, PACKARD 58 AMP AM , PACKARD 58 P, PAM ACKARD 58 P, PACKARD 58 AMP, PACKARD 58 AMP, PACKARD 58 AMP, PACKARD 58 VC1 VC1 VC2 10 1 30 2 3 128 1 1 0 3 8 2 1784 1053 6 7 2 9 41784 5 56 9 6 9 107 3 4 2 51 6 89 1010 3 3 2 128 1 710 48 3 5 2 61 9 8 7 4 5 67 9 4 7 45 56 9 6 9 3 2 1 8 .950[24.13] 3 2 1 8 7 34 2 5 16.950[24.13] 8 7 4 5 6 7 4 5 6 B B .920[23.37] B B .920[23.37] 1.170[29.72] 3 2 1 8 7 4 5 6 B B AMP, PACKARD 58 AMP, PACKARD 58 AMP AMP B B AMP, PACKARD 58 AMP, PACKARD 58 AMP AMP AMP, PACKARD 58 AMP, PACKARD 58 1.266[32.16] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 1.466[37.24] 1.250[31.75] 1.250[31.75] 1.250[31.75] 10 3 2 1 8 7 4 5 6 9 10 3 2 1 8 7 4 5 6 9 A A A AMP, PACKARD 58 A AMP, PACKARD 58 1.266[32.16] 1.466[37.24] 1.266[32.16] 1.466[37.24] 3 2 1 8 7 4 5 6 1.250[31.75] 10 3 2 1 8 7 4 5 6 9 10 3 2 1 8 7 4 5 6 9 PACKARD 630 PACKARD 630 VC2 3 2 1 8 7 4 5 6 PACKARD 630 PACKARD 630 VC1 VC1 VC2 MARKING DETAIL1.266[32.16] MARKING DETMARKING DE AIL MARKING DE TAIL 1.466[37.24] T MARKING DE AIL TAIL MARKING DE MARKING DE 1.266[32.16] TAIL TAILMARKING DETAIL MARKING DE MARKING DE 1.466[37.24] T TAIL AIL MARKING DETAIL MARKING DE MARKING DE TAILTAIL MARKING DE 1.250[31.75] .950[24.13] TAIL MARKING DE MARKING DE TAIL TAILMARKING DETAIL MARKING DETAIL B B FRONT VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRON REAR VIEW T VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRON REAR VIEW T VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW REAR VIEW B B 1.266[32.16] MARKING DE AM T PAIL , PACKARD 58 1.466[37.24] MARKING DE AMP, PACKARD 58 TAIL AMP 1.266[32.16] MARKING DETAIL AMP 1.466[37.24] MARKING DETAIL MARKING DE 1.250[31.75] TAIL MARKING DETAIL AMP, PACKARD 58 AMP, PACKARD 58 MARKING DE 10 3 T2 AIL 1 8 MARKING DE 7 4 T5 AIL 6 9 MARKING DE 10 3 T 2 AIL1 8 MARKING DE 7 4 5TAIL 6 9 MARKING DETAIL MARKING DETAIL FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW 3 2 1 8 7 4 5 6 FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW VC1 VC1 VC1 VC2 VC2 VC2 VCH VCH VCH MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL 1.266[32.16] 1.466[37.24]CONNECTOR HOUSING CONNEC 1.266[32.16] TOR HOUSING CONNECTOR HOUSING 1.466[37.24] 1.250[31.75] CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING FRONT VIEW VC1 REAR VIEW VC2 FRONT VIEW REAR VIEW VCH FRONT VIEW REAR VIEW VC1 (For AMP terminals only) (For AMP terminals only) VC2 (For AMP terminals only) VCH CONNECTOR HOUSING CONNECTOR HOUSING CONNECTOR HOUSING MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL MARKING DETAIL CONNECTOR HOUSING CONNECTOR HOUSING (For AMP terminals only) CONNECTOR HOUSING FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW FRONT VIEW REAR VIEW VC1 (For VC2 AMP terminals only) VCH CONNECTOR HOUSING CONNECTOR HOUSING VC1 VC2 VCH CONNECTOR HOUSING Contura X Boot (P/N VB1-01) Additional V-Series Ratings CONNECTOR HOUSING CONNECTOR HOUSING (For AMP terminals only) CONNECTOR HOUSING (For AMP terminals only) 1 .4VA @ 28VDC Resistive 4 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings 1.050[26.67] 1.050[26.67] 1.050[26.67] 1 1.050[26.67] 5 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified 2 6 15A 125VAC 1/2 HP, 12(2)A 125 VAC μ T85 VB1-01 VB1-01 VB1-01 2 7 VB1-01 15A 125VAC 1/2 HP, 12(6)A 125 VAC T85 2.000[50.80] 2.000[50.80] 2.000[50.80] 1.050[26.67] CONTURA X BOOT CONTURA X BOOT CONTURA X BOOT 1.050[26.67] 2.000[50.80] CONTURA X BOOT 2 8 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC μ T85 1.050[26.67] 2 9 10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85 VB1-01 B 15A 24V 2.000[50.80] CONTURA X BOOT VB1-01 .757[19.23] .757[19.23] .757[19.23] .757[19.23] 2.000[50.80] C 20A 18V CONTURA X BOOT VB1-01 2.000[50.80] D CONTUR 20A 12V A X BOOT E 20A 14V, 10A 14VT (circuits 1, 4, A, & D only) .757[19.23] F 10A 14V, 6A, 14VT (circuit G only) G 20A 6V Contura II, III, IV & V Actuator Removal .757[19.23] Tool H 20A 3V 3.99 [101.35] .757[19.23] 3.99 [101.35] 3.99 [101.35] 3.99 [101.35] L 15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L (P/N VRT) VRT M .4VA/20A 12V (combi-contact) VRT VRT VRT ACTUATOR REMOVAL INSERT POINTS UNDER ACTUATOR .900 [22.86] ACTUATOR REMO TOOL ACTU VALA TOR REMO ACTU VAL ATOR REMOVAL 3.99 [101.35] INSERT POINTS UNDER HOLD FLUSH ON BRACKET INSERT POINTS UNDER AND PUSH INSERT POINTS UNDER (combination gold/silver contacts for borderline dry circuit applications) IN (For flush bracket) ACTUATOR ACTUATOR .900 [22.86] ACTUATOR .900 [22.86] T.900 [22.86] OOL TOOL TOOL HOLD FLUSH ON BRACKET AND PUSH HOLD FLUSH ON BRACKET AND PUSH HOLD FLUSH ON BRACKET AND PUSH TOP IN IN IN (For flush bracket) N (For flush bracket) .4VA/15A (For flush bracket) 24V (combi-contact) VRT TOP TOP TOP ACTUATOR REMOVAL INSERT POINTS UNDER (combination gold/silver contacts for borderline dry circuit applications) ACTUATOR .900 [22.86] TOOL HOLD FLUSH ON BRACKET AND PUSH IN (For flush bracket) TOP 3.99 [101.35] NOTES 3.99 [101.35] Consult factory to determine availability for individual circuits and their HP rating. VRT 1. Not avaiable with Contura 7 or 14 rocker styles. VRT ACTUATOR REMOVAL INSERT POINTS UNDER ACTUATOR REMOVAL INSERT POINTS UNDER 2. Ratings 6 - 9 are UL, CSA & VDE certified, require terminations A or B for double ACTUATOR .900 [22.86] TOOL ACTUATHOLD FLUSH ON BRACKET OR AND PUSH .900 [22.86] TOOL HOLD FLUSH ON BRACKET AND PUSH IN (For flush bracket) pole circuits, & are not available with illumination circuits 4, 8, D, J, N, & T or with IN (For flush bracket) TOP TOP wire lead or solder lug terminations. Circuits 1, 4, A, D, H, M & E are not available with rating 6 & 8. Rating 7 & 9 only available with circuits 1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8. Ratings 6 & 7 must specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp code 2 (250VAC neon). Rating L available with circuits 1, 4, A & D only. Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com TOP TOP TOP TOP TOP TOP TOP | 22 V-Series Contura Sealed Rocker Switch Accessories Contura Mounting Panels Dimensional Specifications: in. [mm] Contura Hole Plug Dimensional Specifications: in. [mm] 1.450 [36.83] TEST CUT VHP HOLE IN .830 [21.08] ACTUAL CONTURA II,III HOLE PLUG MATERIAL 1.240 [31.50] 1.820 [46.23] VHP .430 [10.92] CONTURA II,III HOLE PLUG VH2 STANDARD HOLE PLUG (With wing serrations) VH1 STANDARD HOLE PLUG 2.000 [50.80] (No wing serrations) (With VC1 connector attached) 1.067 [27.10] (TYP. FOR VH3 & VH4) DETAIL VIEW VH3 VH4 VH1,VH3 & VH5 CONTURA IV HOLE PLUG CONTURA IV HOLE PLUG HOLE PLUGS 1.928 [48.97] (No wing serrations) (With wing serrations) (No wing serrations for ease of removal) 1.020 [25.91] (TYP. FOR VH5 & VH6) DETAIL VIEW VH2,VH4 & VH6 VH5 VH6 HOLE PLUGS CONTURA V HOLE PLUG CONTURA V HOLE PLUG (With wing serrations) (No wing serrations) (With wing serrations) Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com | Notes 23 * Intentionally left blank Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Email: sales@carlingtech.com • Application Support: team2@carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: sales@carlingtech.com • www.carlingtech.com East Region Sales Office, CT • ersm@carlingtech.com Midwest Region Sales Office, IL • mrsm@carlingtech.com West Region Sales Office, CA • wrsm@carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Int + 852-2737-2277 • Fax: Int + 852-2736-9332 Email: sales@carlingtech.com.hk Shenzhen, China • shenzhen@carlingtech.com Shanghai, China • shanghai@carlingtech.com Pune, India • india@carlingtech.com Kaohsiung, Taiwan • taiwan@carlingtech.com Yokohama, Japan • japan@carlingtech.com Europe/Middle East/Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Int + 44 1392-364422 • Fax: Int + 44 1392-364477 Email: ltd.sales@carlingtech.com GmbH, Germany • gmbh@carlingtech.com SAS, France • sas@carlingtech.com REV_SW_V_06_2014

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the V2D1B60B-00000-000?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Switch Rocker ON None ON DPDT Solder Lug Small Rocker 5A 250VAC 28VDC Bulk 1M1-DP1-R1/2-M1QE

product

Switch Rocker ON None ON DPDT Solder Lug Rocker 5A 250VAC 28VDC Bulk 1M1-DP1-R6/1-1M1GE

product

Switch Rocker ON None ON DPDT Solder Lug Rocker 5A 250VAC 28VDC Bulk 1M1-DP1-R6/2-2M1GE

product

Switch Rocker ON None ON DPDT Solder Lug Paddle Rocker 5A 250VAC 28VDC Bulk 1M1-DP1-R7/2-2M1GE

product

Switch Rocker ON None ON DPDT Solder Lug Paddle Rocker 5A 250VAC 28VDC Bulk 1M1-DP1-R7/2-2M1QE

product

Switch Rocker ON OFF ON DPDT Solder Lug Small Rocker 5A 250VAC 28VDC Bulk 1M1-DP3-R1/2-M1QE