Part Number 20LPCV2475
Manufacturer CRYDOM
Category Relays and I/O Modules »  I/O Module
Price Request Quote
Lead Time Request Quote

Description

I/O Module Relays 20mA 2500Vrms Flange Mount
20LPCV2475

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Electronics Finder is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 20LPCV2475? We can help you find it at a competitive price!

Specifications

Manufacturer Crydom
Manufacturers Part # 20LPCV2475
Industry Aliases 20LPCV2475
Sub-Category I/O Modules
Factory Pack Quantity 5

Datasheet

Download "l_pcv.pdf" (598 KiB)

Extracted Text

Control Relays DataSheet LPCV Series • Linear proportional controller • Ratings from 15A to 110A @ 240 VAC • 0-5 V DC, 0-10 V DC, or 4-20mA input • For use with resistive loads only PRODUCT SELECTION 15 A Description 25 A 40 A 75 A 110 A 5LPCV2415 5LPCV2425 5LPCV24110 0-5 VDC Control 5LPCV2440 5LPCV2475 0-10 VDC Control 10LPCV2415 10LPCV2425 10LPCV2440 10LPCV2475 10LPCV24110 20LPCV2415 20LPCV2425 4-20 mA Control 20LPCV2440 20LPCV2475 20LPCV24110 (1) OUTPUT SPECIFICATIONS (voltage) Description 240 VAC Operating Voltage (60Hz) [Vrms] 20-300 Transient Overvoltage [Vpk] 600 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 10 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] 200 (1) OUTPUT SPECIFICATIONS (current) Description 15 A 25 A 40 A 75 A 110 A Maximum Load Current [Arms] 15 25 40 75 110 Minimum Load Current [Arms] 0.10 0.10 0.10 0.15 0.20 Maximum Surge Current (16.6ms) [Apk] 150 250 625 1000 1500 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 1.48 Thermal Resistance Junction to Case (Rjc) [°C/W] 1.02 0.31 0.63 0.28 94 260 4150 Maximum I² t for Fusing (8.3 msec) [A² sec] 1620 9340 0.5 0.5 0.5 Minimum Power Factor (with Maximum Load) 0.5 0.5 (1) INPUT SPECIFICATIONS Description 10LPCV 20LPCV 5LPCV Control Voltage Range 0-5 VDC 0-10 VDC 4-20 mA Control Range Limits (Min/Msx) -1.0/20 VDC -0.5/25 mA -0.5/10 VDC Turn-On Threshold 0.25 VDC 0.5 VDC 4.5 mA Nominal Input Impedance 12.7K Ohm 25 K Ohm 460 Ohm Sync Voltage (terminal 6 and 7) 16-24 VAC 16-24 VAC 16-24 VAC (4) POWER SUPPLY SPECIFICATION Description PS240 PS120 Input Voltage 50/60Hz 120 VAC 240 VAC Output Voltage 50/60Hz (Sync Voltage) 20 VAC/100mA 20 VAC/100mA Ambient Operating Temperature Range -30 to 80°C -30 to 80°C Ambient Storage Temperature Range -40 to 125°C -40 to 125°C 6-32 Screws, .25" Fastons Terminals Screw Torque Requirement 6-32 Screws -10 in lbs. Weight (typical) 8.6 oz. (245g) Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Control Relays DataSheet GENERAL SPECIFICATIONS Description Dielectric Strength, signal to load 2500 Vrms Dielectric Strength, signal to Base 2500 Vrms Ambient Operating Temperature Range -30 to 80°C Ambient Storage Temperature Range -40 to 125°C Weight (typical) 6.0 oz. (175g) Encapsulation Themally Conductive Epoxy Terminals 8-32 Screws, .25" Fastons Screw Torque Requirement 8-32 and 10-32 Screws - 20in. lbs. GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. 2) Linear taper potentiometer 1-10K Ohm, ½ watt. 3) 50Hz models available. 4) 20 VAC must be in phase with load WIRING DIAGRAM Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] 1.35 Max. 2.21 (40.6) 2.00 2.10 (56.1) (50.8) (53.3) 1.05 1.52 .12 (26.7) 1.00 (38.6) (3.0) (25.4) 8-32 TERMINALS OUTPUT (2 PLACES) 2.21 2.62 2.50 1.00 PROPORTIONAL CONTROLLER 2.25 (56.1) (66.5) (63.5) (25.4) (57.2) .250 FASTON TERMINALS (5 PLACES) .12 6-32 TERMINALS .30 Typ MOUNTING SLOT (3.0) (2 PLACES) (7.6) .250 FASTON 0.17 (4.3) DIA. .62 PS120/PS240 1.60 Max. TERMINALS (15.7) (40.6) (2 PLACES) Firing Angle vs. Input Signal (20 mA) 10V 5V 7.5V Sync Voltage 5V 2.5V 20 Vac from Power 4 Supply Module 12Vdc Output PS-120 (120Vac) For Manual Control 2.5V - + PS-240 (240Vac) 5 4 3 From Control Note: Not Used 4 See note 2 (4 mA) 0V 0V 0-5 Vdc if Conneced to Voltage range: 16-24Vac 180 135 90 45 0 0-10 Vdc Analog Card 4-20 mA Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Control Relays DataSheet PERCENT VS INPUT VOLTAGE 0-5 Vdc Control 0-10 Vdc Control 4-20 mA Control 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 100 100 100 80 80 80 60 60 60 40 40 40 20 20 20 0 0 0 1 2 3 4 5 1 2 3 4 5 6 7 8 9 10 2 4 6 8 10 12 14 16 18 20 22 Input Voltage Input Voltage Input Voltage THERMAL DERATE INFORMATION 40A 15A 25A 60 90 15 1˚C/W 30 95 .5˚C/W 2˚C/W 112 1˚C/W 1.5˚C/W 25 100 4˚C/W 40 3˚C/W 2˚C/W 100 10 20 2˚C/W 6˚C/W 116 110 15 110 NO HEATSINK 20 120 5 10 NO HEATSINK 120 5 120 NO HEATSINK 124 0 0 10 20 30 40 20 40 60 80 0 3 6 9 12 15 20 40 60 80 5 10 15 20 25 20 40 60 80 Load Current (Amps) Max Ambient Temp. (ºC) Load Current (Amps) Max Ambient Temp. (ºC) Load Current (Amps) Max Ambient Temp. (ºC) 110A 75A 160 120 90 .4˚C/W 95 .2˚C/W 120 .5˚C/W .5˚C/W .3˚C/W 100 100 80 1˚C/W 80 1˚C/W 110 110 40 40 120 120 0 0 30 60 90 120 0 20 40 60 80 10 20 30 40 20 40 60 80 Load Current (Amps) Max Ambient Temp. (ºC) Load Current (Amps) Max Ambient Temp. (ºC) TYPICAL APPLICATIONS • Infrared and quartz heaters • Thermal forming equipment • Resistive heating elements • Conveyor speed control • Rectified DC motors • Printing applications • Industrial temperature controllers AGENCY APPROVALS Agency Approvals Designed in accordance with the requirements of IEC 62314 Rev. 110411 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Percentage ON Power Dissipation Power Dissipation Base Plate Temp (˚C) Power Dissipation Percentage ON Base Plate Temp (˚C) Power Dissipation Base Plate Temp (˚C) Percentage ON Power Dissipation Base Plate Temp (˚C) Base Plate Temp (˚C) Control Relays DataSheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险 HAZARD OF RIESGO DE RISQUE DE GEFAHR EINES RISCHIO DI 存在电击、 ELECTRIC DESCARGA DESCHARGE ELEKTRISCHE SCOSSA 爆炸或电弧 SHOCK, ELECTRICA O ELECTRIQUE N SCHLAGES ELETTRICA O 闪烁危险 EXPLOSION, EXPLOSION. OU EXPLOSION ODER EINER DELL’ESPLOSIONE. OR ARC FLASH. EXPLOSION. • Eteindre • Spenga tutta • 在操作此设 • Desconectar • Disconnect all • Stellen Sie toutes les l'alimentazione todos los 备之前请先 power before jeglichen sources che fornisce suministros de 关闭电源。 Strom ab, der installing or d'énergie de questa energia a este working with dieses Gerät cet appareil apparecchiatura equipo antes 若不遵守这些说明, this equipment. versorgt, bevor avant de prima di lavorare de trabajar 可能会导致严重的 Sie an dem travailler a questa con este equipo. • Verify all Gerät Arbeiten 人身伤害甚至死亡。 dessus de cet apparecchiatura connections • Verificar todas durchführen appareil and replace all las conexiones • Verificare tutti • Vor dem covers before y colocar todas • Vérifier tous i collegamenti Drehen auf turning on las tapas antes e sostituire connections, et Energie alle power. de energizer tutte le coperture remettre tous Anschlüsse el equipo. prima couverts en überprüfen Failure to follow dell’accensione olace avant de und alle these El mettre sous Abdeckungen instructions will L'omissione di incumplimiento ersetzen. De non-suivi de queste istruzioni result in death de estas ces instructions provocherà la or serious injury. Unterlassung instrucciones provoquera la morte o dieser puede provocar mort ou des lesioni serie Anweisungen la muerte o lésions sérieuses können zum lesiones serias. sérieuses. Tode oder zu schweren Verletzungen führen. WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告 RISQUE DE DOMMAGE MATERIEL ET DE GEFAHR VON MATERIALSCHÄDEN UND RISK OF MATERIAL DAMAGE AND HOT SURCHAUFFE DU BOITIER GEHÄUSEERHITZUNG ENCLOSURE • Les panneaux latéraux du produit peuvent être • Die Seitenwände können heiß sein. Lassen Sie • The product's side panels may be hot, allow chauds. Laisser le produit refroidir avant de le das Produkt abkühlen, bevor Sie es berühren. the product to cool before touching. toucher. • Beachten Sie die Montageanweisungen, • Follow proper mounting instructions including • Respecter les consignes de montage, et • Führen Sie keine Flüssigkeiten oder torque values. notamment les couples de serrage. Fremdkörper in das Produkt ein. • Do not allow liquids or foreign objects to enter • Ne pas laisser pénétrer de liquide ni de corps this product. étrangers à l'intérieur du produit. Le non-respect de cette directive peut entraîner, Die Nichtbeachtung dieser Anweisung kann Failure to follow these instructions can result in des lésions corporelles graves ou des Körperverletzung oder Materialschäden serious injury, or equipment damage. dommages matériels. zur Folge haben. RIESGO DE DAÑOS MATERIALES Y DE 材料损坏和高温外壳的危险性 RISCHIO DI DANNI MATERIALI E D'INVOLUCRO SOBRECALENTAMIENTO DE LA UNIDAD CALDO • 产品的一侧面板可能很热,在其冷却前请 • Los paneles laterales del producto pueden • I pannelli laterali dell'apparecchio possono 不要触碰。 estar calientes. Esperar que el producto se scottare; lasciar quindi raffreddare il prodotto • 遵照正确的安装说明,包括扭矩值。 enfríe antes de tocarlo. prima di toccarlo. • 请勿让液体及其他异物进入本产品。 • Respetar las instrucciones de montaje, y en • Seguire le istruzioni di montaggio corrette. particular los pares de apretado. • Non far entrare liquidi o oggetti estranei in questo • No dejar que penetren líquidos o cuerpos apparecchio. extraños en el producto. La mancata osservanza di questa precauzione può 如不能正确执行这些操作说明, Si no se respetan estas precauciones pueden causare gravi rischi per l'incolumità personale o 极有可能造成严重人体伤害或者设备的损坏。 producirse graves lesiones, daños materiales. danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. Control Relays DataSheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Toxic or hazardous Substance and Elements Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) Semiconductor die Solder 附件 - 环保信息 此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006, 电子信息产品污染控制标识要求。 部件 有毒有害物质或元素 名称 铅 汞 镉 六价铬 多溴联苯 多溴二苯醚 (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) 半导体芯片 焊接点 50 Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice.

Related Products

CRYDOM
I/O Module Relays 0VDC to 5VDC 2500Vrms Flange Mount 5LPCV2425
CRYDOM
I/O Module Relays Input Module 120VAC 5mA 4000VAC Thru-Hole MIAC5
CRYDOM
I/O Module Relays Output Module 24VDC 4000Vrms Thru-Hole MOAC24A
CRYDOM
I/O Module Relays Output Module 5VDC 27mA 4000Vrms Thru-Hole M-OAC5
CRYDOM
I/O Module Relays Output Module 5VDC 27mA 4000Vrms Thru-Hole MOAC5A
CRYDOM
I/O Module Relays Output Module 24VDC 13mA 4000VAC Thru-Hole MODC24

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Electronics Finder are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.