Specifications
Manufacturer
E-T-A
Manufacturers Part #
110-P10-G10-OB01-10A
Industry Aliases
110-P10 G10-OB0110A
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
Thermal Overcurrent Circuit Breakers 110/111-P10-G10 Description Single pole toggle switch/thermal circuit breakers (S-type TO CBE to EN 60934) for threadneck panel mounting. Available with optional neon illumination (filament bulb for low voltages) to indicate the ON position. Fitted with toggle or baton style actuator in a range of colours - translucent for illuminated version. Under overload the actuator returns to the OFF position. For two or three pole protection see types 3120 and 3130. 1 Typical applications Motors, transformers, solenoids, extra-low voltage wiring systems, 110-P10-G10 power supplies. 111-P10-G10 (illuminated) Ordering information Technical data Type No. Voltage rating AC 250 V; DC 28 V 110 non illuminated Current ratings 0.1...20 A (type 110) 111 illuminated (please specify voltage) 0.1...16 A (type 111) Terminal design Typical life 30,000 operations at 1 x I or P10 blade terminals A6.3-0.8 (QC .250) N 5,000 operations at 2 x I Shunt terminal (optional) N A3 shunt terminal, max. load 5 A Ambient temperature -30...+60 °C (-22...+140 °F) Mounting Insulation co-ordination rated impulse pollution G10 threadneck panel mounting, 1/2-32UN-2A* (IEC 60664 and 60664 A) withstand voltage degree Switch style options 2.5 kV 2 OB baton reinforced insulation in operating area WB baton - water splash protected (IP54) Dielectric strength OT toggle (IEC 60664 and 60664A) test voltage WT toggle - water splash protected (IP54) operating area AC 3,000 V Switch colour designation opaque translucent for type 111 Insulation resistance > 100 MΩ (DC 500 V) 01 black 14 red Interrupting capacity I 10 x I cn N 02 white 15 orange Interrupting capacity I U N N 04 red 17 transparent (UL 1077) 0.1...16 A AC 250 V 2,000 A 06 blue 18...20 A AC 125 V 2,000 A 08 grey 09 green Degree of protection operating area IP40 Current ratings (IEC 60529/DIN 40 050) terminal area IP00 0.1...20 A (type 110) Vibration 4 g (57-500 Hz) ±0.3 mm (10-57 Hz), 0.1...16 A (type 111) to IEC 60068-2-6, test Fc, Illumination (type 111 only) 10 frequency cycles/axis 12 V DC 10 to 14 V Shock 30 g (11 ms), to IEC 60068-2-27, test Ea 24 V DC 20 to 28 V 115 V AC 90 to 140 V Corrosion 48 hours at 5 % salt mist, 220 V AC 185 to 275 V to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH 111 - P10 - .. - G10 - OB 14 - 5 A - 12 V = ordering example to IEC 60068-2-3, test Ca The exact part number required can be built up from the table of choices shown Mass approx. 30 g above. Ordering references for optional features should be omitted if not required. *mounting hardware bulk shipped Standard current ratings and typical internal resistance values Approvals CurrentInternal CurrentInternal CurrentInternal Authority Voltage ratings Current ratings rating (A) resistance (Ω) rating (A) resistance (Ω) rating (A) resistance (Ω) CSA / UL AC 250 V; DC 28 V 0.1...16 A 0.1 97.6 1.2 0.66 6 0.03 AC 125 V; DC 28 V 18...20 A 0.2 22.4 1.5 0.50 8 < 0.02 0.3 10.9 1.8 0.33 10 < 0.02 0.4 6.1 2 0.27 12 < 0.02 0.5 4.0 2.5 0.2 15 < 0.02 0.6 2.7 3 0.1 16 < 0.02 0.7 1.8 3.5 0.09 18 < 0.02 0.8 1.6 4 0.05 20 < 0.02 1 1.07 5 0.04 06/07 www.e-t-a.com 1 - 17 Thermal Overcurrent Circuit Breakers 110/111-P10-G10 Dimensions 110/111-P10-G10-... Installation drawings 110/111-P10(-A3)-G10-OB../-WB.. 110-P10-G10-OB../-WB../-OT../-WT.. tightening torque 1.5 Nm 1 / -32 UNS-2A 2 operating area ø4.6 .181 1 5 5 5 5 .197 .197 .197 .197 mounting area 110-P10-A3-G10-OB../-WB../-OT../-WT.. operating area 24.4 20 .961 blade terminal .787 43.3 DIN 46244-A6.3-0.8 (QC .250) 1.70 mounting hole 5 5 5 5.5 15 .197 .197 .197 .217 .591 mounting area 12 -0.1 .472-.004 111-P10-G10-OB../-WB../-OT../-WT.. operating area 110/111-P10(-A3-)G10-OT../-WT.. 8 .315 15 5.5 5 5 5 .217 .197 .197 .197 .591 mounting area 111-P10-A3-G10-OB../-WB../-OT../-WT.. Typical time/current characteristics at +23°C/+73.4°F operating area 10000 0.1 -2.5 A 3 - 20 A 1000 15 15 5 5 .591 .591 .197 .197 mounting area 100 Internal connection diagrams 10 110-P10-... 111-P10-... 1 1 1 0.1 12 46810 20 40 … times rated current 2 2 5 The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also mm This is a metric design and millimeter dimensions take precedence ( ) section 9 – Technical information. inch Ambient temperature °F -22 -4 +14 +32 +73.4 +104 +122 +140 All dimensions without tolerances are for reference only. In the interest of improved design, °C -30 -20 -10 0 +23 +40 +50 +60 performance and cost effectiveness the right to make changes in these specifications Derating factor 0,68 0.76 0.84 0.92 1 1.08 1.16 1.24 without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 1 - 18 www.e-t-a.com 06/07 10° SW 16 .630 Trip time in seconds terminal for 5 illumination .197 (type 111 only) 12 12.7 9.5 16 36 12 1.42 .630 .472 .500 .374 .472 12.7 -0.1 .500 -.004 24.5 .965 20.5 .807 32 20.5 32 24.5 32 20.5 32 24.5 1.26 1.26 1.26 .807 1.26 .807 .965 .807
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the 110-P10-G10-OB01-10A?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
Related Products

MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...

MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods