E-T-A 3120-F321-P7T1-W02D-20A

Image of E-T-A 3120-F321-P7T1-W02D-20A

Description

Circuit Breaker Thermal 2Pole 20A 240VAC/50VDC

Part Number

3120-F321-P7T1-W02D-20A

Price

Request Quote

Manufacturer

E-T-A

Lead Time

Request Quote

Category

Circuit Protection »  Circuit Breaker

Specifications

Manufacturer

E-T-A

Manufacturers Part #

3120-F321-P7T1-W02D-20A

Sub-Category

Circuit Breakers

Factory Pack Quantity

1

Datasheet

pdf file

D_3120-DD_e_020810.pdf

977 KiB

Extracted Text

Thermal Overcurrent Circuit Breaker 3120-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 60934 with trip free mechanism) offering the choice of single pole, double pole with single pole protection, and double pole with protection on both poles. Designed for snap-in panel mounting with versions available for three different panel cut-out sizes. Illumination is optional and there is a range of colours and markings for the rocker. Under overload conditions the rocker returns to the OFF position. 6-way frame for 3120-F5 available upon request. 1 Any one of the following additional function modules can be supplied factory fitted to the rear of the switch/circuit breaker. ● Under voltage release coil (for double pole versions only). ● Magnetic trip coil for short circuit protection. ● Magnetic trip coil for remote relay trip. ● Auxiliary contacts for status signalling. ● Mechanical slide interlock. 3120-F... Approved to CBE standard EN 60934 (IEC 60934). Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02 Safety of household and similar electrical appliances. Technical data Typical applications For further details please see chapter: Technical Information Voltage rating AC 240 V; DC 50 V Motors, transformers, solenoids, extra low voltage wiring systems, office (AC 415 V to special order) machines, electro-medical equipment, power supplies, communications (UL: AC 250 V; DC 50 V) systems, medical equipment to EN 60601. Current ratings 0.1...20 A (up to 30 A to special order, single pole only) Standard current ratings and typical internal resistance values Typical life 1-pole AC 240 V: 0.1...20 A 30,000 operations at 1 x I , inductive N DC 50 V: 0.1...4 A 30,000 operations at 1 x I , inductive Current Internal resistance Current Internal resistance N 4.5...16 A 30,000 operations at 1 x I , resistive rating (A) per pole (Ω) rating (A) per pole (Ω) N DC 28 V: 4.5...20 A 30,000 operations at 1 x I , inductive N 0.1 94 4 0.0435 2-pole 0.2 24 4.5 0.0435 AC 415 V: 0.1...16 A 10,000 operations at 1 x I , inductive N AC 240 V: 0.1...16 A 50,000 operations at 1 x I , inductive 0.3 12 5 0.0325 N 17...20 A 30,000 operations at 1 x I , inductive N 0.4 5.30 6 0.0215 DC 50 V: 0.1...16 A 50,000 operations at 1 x I , inductive N 0.5 4.20 7 0.0165 17...20 A 10,000 operations at 1 x I , inductive N 0.6 2.90 8 0.0165 Ambient temperature -30...+60 °C (-22...+140 °F) 0.8 1.50 10 < 0.02 Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A withstand voltage degree 1 0.9 12 < 0.02 2.5 kV 2 1.2 0.80 14 < 0.02 reinforced insulation in operating area 1.5 0.45 15 < 0.02 Dielectric strength 2 0.27 16 < 0.02 (IEC 60664 and 60664A) test voltage 2.5 0.0785 18 < 0.02 operating area AC 3,000 V between poles (2-pole) AC 1,500 V 3 0.0595 20 < 0.02 Insulation resistance > 100 MΩ (DC 500 V) 3.5 0.0565 Interrupting capacity I 0.1...2 A 10 x I cn N 2.5...20 A 250 A 2-pole, or 150 A 1-pole Illumination voltage/power consumption Interrupting capacity I U 2-pole N N (UL 1077) 0.1...2 A AC 250 V 200 A 2.5...3 A AC 250 V 1,000 A operating voltage power consumption 3.5...8 A AC 250 V 2,000 A Y + R G T 9...16 A AC 250 V 3,500 A 12 V 2 mA 3.5 mA 4.9 mA 18...20 A AC 250 V 5,000 A 24 V 2 mA 3.5 mA 4.9 mA 0.1...20 A DC 50 V 1,000 A 48 V 2 mA 3.5 mA 4.9 mA Degree of protection operating area IP40 (IEC 60529/DIN 40050) (IP54 with water splash protection) 115 V 0,9 mA 2.8 mA 2.2 mA terminal area IP00 230 V 0,9 mA 2.8 mA 2.2 mA Vibration 8 g (57-500 Hz), ± 0.61 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Approvals Shock 30 g (11 ms) to IEC 60068-2-27, test Ea Authority Voltage ratings Current ratings Corrosion 96 hours at 5 % salt mist, VDE (EN 60934) AC 240 V; DC 28 V 0.1...20 A to IEC 60068-2-11, test Ka DC 50 V 0.1...20 A 2-pole Humidity 240 hours at 95 % RH, DC 50 V 0.1...10 A 1-pole to IEC 60068-2-78, test Cab UL, CSA AC 250 V; DC 50 V 0.1...20 A Mass approx. 33 g (double pole) CCC AC 250 V; DC 50 V 0.1...20 A approx. 27 g (single pole) Issue B(211209) www.e-t-a.com 1 - 67 Thermal Overcurrent Circuit Breaker 3120-F... Ordering information Typical time/current characteristics Type No. single or double pole load 3120 rocker switch/circuit breaker Mounting 0.1…2 A F snap in frame 10000 +60 °C +140 °F Size of frame panel thickness 3 to fit mounting cut-out 50.5 x 21.5 mm 1-6.35 mm (.039-.250 in) +23 °C +73.4 °F 5 to fit mounting cut-out 44.5 x 22 mm 1-4 mm (.039-.157 in) 6 to fit mounting cut-out 45 x 33.7 mm 1.2-2.4 mm (.047-.094 in) -30 °C 1000 1 -22 °F Number of poles 0 2-pole, unprotected, switch only 1 1-pole, thermally protected 2 2-pole, thermally protected 100 5 2-pole, thermally protected on one pole only (terminals 11,12k,12i) 6 1-pole, unprotected, switch only Mounting frame design 1 collar height 1 mm 3 collar height 9 mm 10 4 collar height 2 mm with water splash protection (IP54), not with -F6... U with water splash protection and actuator guard Terminal configuration P7 blade terminals 2x2.8x0.8 mm (QC 2x.110) 1 (terminals 12(k), 22(k), 11, 21), not for under voltage module, not for switch H7 12(k), 22(k): blade terminals 2x2.8-0.8 (QC 2x.110) 11, 21: terminal screws, not for switch 0.1 N7 as P7, but including shunt terminals 12(i) and 22(i) 12 46810 20 40 as blade terminals 2x2.8x0.8 mm (QC 2x.110) … times rated current not for under voltage module 2.5…20 A G7 as H7, but including shunt terminals 12(i) and 22(i) 10000 +60 °C as blade terminals 2x2.8x0.8 mm (QC 2x.110) +140 °F Characteristic curve +23 °C T1 thermal, 1.01-1.4 x I +73.4 °F N Q1 switch only -30 °C 1000 -22 °F Actuator style W rocker U momentary switch Switch colour designation opaque translucent 100 (for illuminated versions) 01 black 12 white 02 white 14 red 04 red 15 orange 10 16 sky blue 19 green Rocker markings A 0 AUS OFF 1 B I EIN ON C D 0 AUS OFF E I EIN ON F 0.1 AB C D E F X 12 46810 20 40 X … times rated current X = without marking Rocker illumination (optional) . 12 . Y white rocker, yellow LED The time/current characteristic curve depends on the ambient temperature . 12 . T white rocker, blue LED prevailing. In order to eliminate nuisance tripping, please multiply the circuit . 14 . R red rocker, red LED breaker current ratings by the derating factor shown below. See also section . 15 . Y orange rocker, yellow LED Technical information. . 16 . T blue rocker, blue LED Ambient temperature °F -22 -4 +14 +32 +73.4 +104 +122 +140 . 19 . G green rocker, green LED °C -30 -20 -10 0 +23 +40 +50 +60 Illumination voltage range Derating factor 0.8 0.76 0.84 0.92 1 1.08 1.16 1.24 1 10 - 14 V AC/DC 2 20 - 28 V AC/DC 3 90 - 140 V AC 4 185 - 275 V AC 5 42 - 54 V AC/DC Current ratings 0.1...20 A 3120 - F 3 2 1 - N7 T1 - W 14 A R 4 - 10 A ordering example 3120 - F . 0 . - N7 Q1 - W .. . . . - 20 A (switch only) N.B. Switch only versions must be specified with -N7 or -G7 terminals. Terminals 12(k) and 22(k) are not fitted. 1 - 68 www.e-t-a.com Issue B(211209) Trip time in seconds Trip time in seconds Thermal Overcurrent Circuit Breaker 3120-F... Internal connection diagrams Mounting style variants Style F 3.3 collar height 9 mm (.354 in.) 2-pole, 2-pole, thermally protected on both poles thermally protected on one pole only 25 54 line line .984 2.13 11 21 21 11 19.5 35 .768 1.38 12(i) 22(i) 12(i) 22(i) 1 12(k) 22(k) 12(k) load load 12(i) 12(k) 11 1-pole, 2-pole, thermally protected unprotected line line 10.7 3.5 3 11 11 21 .421 .138 .118 21 15.5 .827 .610 blade terminals DIN 46244-C-Ms-S 41 (QC 2x.110) 12(i) 22(i) 1.61 12(i) 22(i) flat head screw M3.5x5-MS ISO1580 load tightening torque max. 0.8 Nm 12(k) load Style F 3.4 collar height 2 mm (.079 in.), with water splash protection 27 56 1.06 2.21 35 19.5 Dimensions 1.38 .768 Style F3.1 collar height 1 mm/.039 in. Actuating force max. 35 N optional illumination in ON position 12(i) 12(k) 11 25 OFF position .984 16 54 10.7 3.5 3 .630 2.13 .421 .118 .138 21 15.5 .827 .610 41 blade terminals DIN 46244-C-Ms-S 1.61 (QC 2x.110) flat head screw M3.5x5-MS ISO1580 tightening torque max. 0.8 Nm Style F 5.1 25 Optional illumination .984 16 48 .630 1.89 12(i) 12(k) 11 10.7 3.5 3 .421 .138 .118 21 12(i) 12(k) 11 15.5 .827 .610 41 blade terminals DIN 46244-C-Ms-S 10.7 3.5 3 (QC 2x. 110) 1.61 .421 .138 .118 21 15.5 flat head screw ISO1580 M3.5x5-MS .827 .610 tightening torque max. 0.8 Nm 41 blade terminals DIN 46244-C-Ms-S (QC 2x.110) 1.61 flat head screw M3.5x5-MS ISO1580 tightening torque max. 0.8 Nm Installation drawing Style F 5.U with water splash protection (IP54) and actuator guard 50 27 1.97 1.06 24 44.2-0,2 When installing the circuit breaker apply pressure on bezel only .945 1.74-.008 21,5-0,1 5,3 24.1 .209 .949 .846-.004 operating area 19.5 35 .768 1.38 12(i) 12(k) 11 12(i) 12(k) 11 10.7 3,5 3 .421 .138 .118 21 15.5 .827 .610 blade terminals DIN 46244-C-Ms-S 41 7 7 710 8 1.61 flat head screw M3.5x5-MS ISO1580 .276 .276 .315 .276 .394 tightening torque max. 0.8 Nm mounting area Dimension diagram for style F6 is available on request mm This is a metric design and millimeter dimensions take precedence ( ) inch Issue B(211209) www.e-t-a.com 1 - 69 35 7 1.38 .276 33 1.30 10 .394 10 15.5 .394 .610 35 7 3.8 10 35 9 37 1.38 .276 .150 .394 1.38 .354 1.46 33 33 33 33 1.30 1.30 1.30 1.29 10 .394 7 .276 4 .157 10 10 10 10 .394 .394 .394 .394 R3.5 .138 Thermal Overcurrent Circuit Breaker 3120-F... Accessories Insulated cover Rear terminal shroud black (IP64) Y 303 068 01 Y 304 275 01 2.5 40.5 .098 +0.5 1.59 1.75 20.5 -0.25 +.020 .069 .807 -.010 1 20 .787 Terminal adapter Y 303 862 01 4 .157 ø8 .315 Water splash cover, transparent (IP66) for style -F5.. X 221 619 01 48 1.89 blade terminal DIN 46244-C-Ms-S (QC 2x.110) Spacer for 3120-F3... Y 303 675 01/02 58 ø8 2.28 .315 50.5 1.99 ø4.4 .173 * Y 303 675 01 suitable for * panel thickness < 2 mm (.079 in) * Y 303 675 02 suitable for panel thickness < 4 mm (.157 in) 60 2.36 Spacer for 3120-F5... 73 Y 303 676 01 2.87 52 6-way frame for 3120-F5... upon request 2.05 44.5 1.75 Cut-out dimensions 1 .039 Cut-out for mounting style -F3 Cut-out for mounting style -F6 with rocker and push button with rocker - 0.4 sharp-edged - 0.4 -.016 -.016 - 0.2 - 0.2 -.008 min. 2.5 -.008 min. 2 min .098 min .079 without bends max. R2 max. R1.5 max .079 max .059 ±0.05 ±0.05 ±.002 ±.002 max. R0.3 Blanking piece in -F3 frame +0.3 “A” 50.5 max. R0.3 max .012 Y 303 885 31 +.012 1.99 max .012 54 25 matt finish 2.13 .984 31 16.5 +0. .650 1.22 Cut-out for mounting style -F5 with rocker - 0.4 -.016 - 0.2 min. 2 -.008 min .079 +0.4 +0.8 +1 max. R1.5 mm 1.2 1.6 2.4 panel max .059 +.016 +.031 +.039 thickness inch .047 .063 .094 ±0.05 +0,2 +1.1 +2.2 ±.002 45 45 mm 45 dimension - 0.05 - 0.05 - 0.05 +0.2 44.5 +.008 +.043 +.087 “A” inch 1.77 1.77 1.77 - .002 - .002 - .002 +.008 41 21 1.75 1.61 .827 max. R0.3 max .012 Edges of working parts: ISO 13715 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. mm This is a metric design and millimeter dimensions take precedence ( ) Errors and omissions excepted. inch 1 - 70 www.e-t-a.com Issue B(211209) +0.2 21.5 1-6.35 1-4 mm +.008 .846 .039-.250 .039-.157 in. 3.4 .134 10 50 .394 1.97 +0.3 22 +.012 .866 +0.2 panel thickness 33.7 - 0.05 +.008 1.33 - .002 35 16.5 25 1.38 .650 .984 +5 70 +.197 2.76 1 .039 13.5 .531 1 4 .039 .157 0.9 .035 9 .354 3.7 22 0.8 22.5 .146 .031 .886 .866 2.5 28 28 .098 1.10 1.10 33 1.30 36 1.42 Thermal Overcurrent Circuit Breaker 3120-F7.. Description E-T-A’s proven type 3120 in a new attractive styling (S-type TO CBE to EN 60934 with trip free mechanism) offering the choice of single pole, double pole with single pole protection, and double pole with protection on both poles. Designed for snap-in panel mounting with illumination as an option. Under overload conditions the rocker returns to the OFF position. Any one of the following additional function modules can be supplied factory fitted to the rear of the switch/circuit breaker. ● Under voltage release coil (for double pole versions only). 1 ● Magnetic trip coil for short circuit protection. ● Magnetic trip coil for remote relay trip. ● Auxiliary contacts for status signalling. ● Mechanical slide interlock. Approved to CBE standard EN 60934 (IEC 60934). Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02 3120-F7.. Safety of household and similar electrical appliances. Available accessories: water splash protection and actuator guard to Technical data prevent inadvertent operation. For further details please see chapter: Technical Information Typical applications Voltage rating AC 240 V; DC 50 V (AC 415 V to special order) Motors, transformers, solenoids, extra low voltage wiring systems, office (UL: AC 250 V; DC 50 V) machines, electro-medical equipment, power supplies, communications Current ratings 0.1...20 A systems, boating. (up to 30 A to special order, single pole only) Typical life 1-pole AC 240 V: 0.1...20 A 30,000 operations at 1 x I , inductive N Standard current ratings and typical internal resistance values DC 50 V: 0.1...4 A 30,000 operations at 1 x I , inductive N 4.5...16 A 30,000 operations at 1 x I , resistive N DC 28 V: 4.5...20 A 30,000 operations at 1 x I , inductive Current Internal resistance Current Internal resistance N 2-pole rating (A) per pole (Ω) rating (A) per pole (Ω) AC 415 V: 0.1...16 A 10,000 operations at 1 x I , inductive N 0.1 94 4 0.0435 AC 240 V: 0.1...16 A 50,000 operations at 1 x I , inductive N 0.2 24 4.5 0.0435 17...20 A 30,000 operations at 1 x I , inductive N 0.3 12 5 0.0325 DC 50 V: 0.1...16 A 50,000 operations at 1 x I , inductive N 17...20 A 10,000 operations at 1 x I , inductive N 0.4 5.30 6 0.0215 Ambient temperature -30...+60 °C (-22...+140 °F) 0.5 4.20 7 0.0165 Insulation co-ordination rated impulse pollution 0.6 2.90 8 0.0165 (IEC 60664 and 60664 A withstand voltage degree 0.8 1.50 10 < 0.02 2.5 kV 2 1 0.9 12 < 0.02 reinforced insulation in operating area 1.2 0.80 14 < 0.02 Dielectric strength (IEC 60664 and 60664A) test voltage 1.5 0.45 15 < 0.02 operating area AC 3,000 V 2 0.27 16 < 0.02 between poles (2-pole) AC 1,500 V 2.5 0.0785 18 < 0.02 Insulation resistance > 100 MΩ (DC 500 V) 3 0.0595 20 < 0.02 Interrupting capacity I 0.1...2 A 10 x I cn N 3.5 0.0565 2.5...20 A 250 A 2-pole, or 150 A 1-pole Interrupting capacity I U 2-pole N N (UL 1077) 0.1...2 A AC 250 V 200 A 2.5...3 A AC 250 V 1,000 A Illumination voltage/power consumption 3.5...8 A AC 250 V 2,000 A 9...6 A AC 250 V 3,500 A operating voltage power consumption 18...20 A AC 250 V 5,000 A Y + R G T 0.1...20 A DC 50 V 1,000 A 12 V 2 mA 3.5 mA 4.9 mA Degree of protection operating area IP40 24 V 2 mA 3.5 mA 4.9 mA (IEC 60529/DIN 40050) (IP54 with water splash protection) terminal area IP00 48 V 2 mA 3.5 mA 4.9 mA Vibration 8 g (57-500 Hz), ± 0.61 mm (10-57 Hz) 115 V 0,9 mA 2.8 mA 2.2 mA to IEC 60068-2-6, test Fc 230 V 0,9 mA 2.8 mA 2.2 mA 10 frequency cycles/axis Shock 30 g (11 ms) to IEC 60068-2-27, test Ea Approvals Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Authority Voltage ratings Current ratings Humidity 240 hours at 95 % RH, VDE (EN 60934) AC 240 V; DC 28 V 0.1...20 A to IEC 60068-2-78, test Cab DC 50 V 0.1...20 A 2-pole Mass approx. 33 g (double pole) DC 50 V 0.1...10 A 1-pole approx. 27 g (single pole) UL, CSA AC 250 V; DC 50 V 0.1...20 A CCC AC 250 V; DC 50 V 0.1...20 A Issue B(300410) www.e-t-a.com 1 1 - 71 - 71 Thermal Overcurrent Circuit Breaker 3120-F7.. Ordering information Typical time/current characteristics Type No. single or double pole load 3120 rocker switch/circuit breaker Mounting 0.1…2 A F snap in frame 10000 +60 °C Size of frame panel thickness +140 °F 7 to fit mounting cut-out 44.5x22 mm (1.75x.866 in) 1-4 mm (.039-.157 in) +23 °C Number of poles +73.4 °F 0 2-pole, unprotected, switch only -30 °C 1 1000 -22 °F 1 1-pole, thermally protected 2 2-pole, thermally protected 5 2-pole, thermally protected on one pole only (terminals 11,12k,12i) 6 1-pole, unprotected, switch only Mounting frame design 100 N grey frame P snap-on actuator guard grey Q snap-on water splash cover grey R black frame 10 S snap-on actuator guard black T snap-on water splash cover black Terminal configuration P7 blade terminals 2x2.8x0.8 mm (QC 2x.110) (terminals 1 12(k), 22(k),11, 21), not for under voltage module, not for switch H7 12(k), 22(k): blade terminals 2x2.8-0.8 (QC 2x.110) 11, 21: terminal screws, not for switch N7 as P7, but including shunt terminals 12(i) and 22(i) 0.1 12 46810 20 40 as blade terminals 2x2.8x0.8 mm (QC 2x.110) … times rated current not for under voltage module 2.5…20 A G7 as H7, but including shunt terminals 12(i) and 22(i) 10000 +60 °C as blade terminals 2x2.8x0.8 mm (QC 2x.110) +140 °F Characteristic curve +23 °C T1 thermal, 1.01-1.4 x I N +73.4 °F Q1 switch only -30 °C Actuator style 1000 -22 °F A rocker Switch colour designation opaque translucent 01 black 12 white 100 02 white 14 red 04 red 15 orange 09 green 19 greeen 20 blue 30 blue 10 26 sky blue 36 sky blue Rocker markings I 1 0 Q 0.1 Q „I“ and „0“ moulded in 12 46810 20 40 Push button illumination (optional) … times rated current 12 Q T white wocker, blue LED 14 Q R red rocker, red LED 15 Q Y orange rocker, yellow LED The time/current characteristic curve depends on the ambient temperature 19 Q G green rocker, green LED prevailing. In order to eliminate nuisance tripping, please multiply the circuit 30 Q G blue rocker, green LED breaker current ratings by the derating factor shown below. See also section 36 Q T sky blue rocker, blue LED Technical information. Illumination voltage range (optional) Ambient temperature °F -22 -4 +14 +32 +73.4 +104 +122 +140 1 10 - 14 V °C -30 -20 -10 0 +23 +40 +50 +60 2 20 - 28 V Derating factor 0.8 0.76 0.84 0.92 1 1.08 1.16 1.24 3 90 - 140 V 4 185 - 275 V 5 42 - 54 V AC/DC Current ratings 0.1...20 A 3120 - F 7 2 N - N7 T1 - A 30 Q T 4 - 10 A ordering example 3120 - F . 0 N - N7 Q1 - A 30 Q T 4 - 20 A (switch only) N.B. Switch only versions must be specified with -N7 or -G7 terminals. Terminals 12(k) and 22(k) are not fitted. 1 - 72 www.e-t-a.com Issue B(300410) Trip time in seconds Trip time in seconds Thermal Overcurrent Circuit Breaker 3120-F7.. Dimensions Internal connection diagrams Style -F7.N and F7.R 2-pole, 2-pole, thermally protected on both poles thermally protected on one pole only ±0.2 25 48 ±.008 .984 1.89 line line 11 21 11 21 15.5 44.2-0.2 1.74-.008 .610 12(i) 22(i) 12(i) 22(i) 1 12(k) 22(k) 12(k) load load 1-pole, 2-pole, LINE thermally protected unprotected 12(i) 12(k) 11 line line 11 11 21 3 10.7 3.5 .421 .138 .118 12(i) 22(i) 21 15.5 12(i) 22(i) .827 .610 load 41 12(k) load 1.61 blade terminals DIN 46244-C-Ms-S (QC 2 x .110) flat head screw ISO1580 M3.5x5-MS tightening torque max. 0.8 Nm Installation drawing Style -F7.P and F7.S 60 34 1.34 2.36 When installing the circuit breaker apply pressure on bezel only. 18.8 44.2-0,2 .740 1.74-.008 operating area 15.5 .610 LINE 12(i) 12(k) 11 LINE 12(i) 12(k) 11 3.5 3 10.7 .138 .118 .421 15.5 21 7 710 7 8 .610 .827 .276 .276 .315 .276 .394 41 mounting area 1.61 blade terminals DIN 46244-C-Ms-S (QC 2 x .110) flat head screw ISO1580 M3.5x5-MS tightening torque max. 0.8 Nm Panel cut-out Style -F7.Q and F7.T 34 60 1.34 2.36 -0,4 18.6 44.8 -.016 -0,2 .732 1.76 min. 2 -.008 min .079 max. R1.5 ±0,05 max .059 ±.002 +0.4 44.5 max. R0.3 LINE +.016 12(i) 12(k) 11 1.75 max .012 3.5 3 10.7 .421 .138 .118 Edges of working parts: ISO 13715 21 15.5 .827 .610 41 1.61 blade terminals DIN 46244-C-Ms-S (QC 2 x .110) flat head screw ISO1580 M3.5x5-MS tightening torque max. 0.8 Nm mm This is a metric design and millimeter dimensions take precedence ( ) inch Issue B(300410) www.e-t-a.com 1 - 73 33 33 8.9 33 8.9 1.30 1.30 .350 1.30 .350 10 10 10 3 5.9 11.5 .394 .394 .118 .394 .232 .453 +0.3 22 1- 4 +.012 .039 - .157 .866 10 15.5 .394 .610 R3.5 .138 Thermal Overcurrent Circuit Breaker 3120-F7.. Accessories Translucent water splash cover (IP54) Insulated cover X 222 143 01 Y 303 068 01 Consisting of 2.5 - Y 307 097 01 snap-on frame with actuator guard .098 - Y 307 096 01 soft plastic cover 18.8 11.5 .453 .740 1 20 .787 Terminal adapter Y 303 862 01 4 .157 34 10.1 1.34 .398 blade terminal DIN 46244-C-Ms-S Snap-on frame with actuator guard (can be snapped on (QC 2x.110) as switch-on protection or switch-off protection) Y 307 097 01 5.9 18.8 .740 .232 Spacer Y 303 676 01 52 2.05 44.5 1.75 1 .039 sharp-edged 34 10.1 1.34 .398 without bends Rear terminal shroud black (IP64) Y 304 275 01 40.5 +0.5 1.59 1.75 -0.25 20.5 +.020 .069 .807 -.010 ø8 .315 mm This is a metric design and millimeter dimensions take precedence ( ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 1 - 74 www.e-t-a.com Issue B(300410) 13.5 .531 1 4 .039 .157 0.9 .035 9 10 50 .354 .394 1.97 3.7 0.8 22.5 .146 .031 .886 2.5 28 1.10 .098 +5 70 +.197 2.76 60 60 2.36 2.36 Thermal Overcurrent Circuit Breaker 3120-F... Description Switch/thermal trip free circuit breaker (S-type TO CBE to EN 60934) with standard isolator style two button operation. Single button press-to-reset version also available. Both types can be supplied in single pole configuration only, in double pole with single pole protection, and in double pole with protection on both poles. Designed for snap-in panel mounting. There is a choice of push button colour combinations and illumination is optional. Any one of the following additional function modules can be supplied factory fitted to the rear of the switch/circuit breaker: 1 ● Under voltage release coil (for double pole versions only). ● Magnetic trip coil for short circuit protection. ● Magnetic trip coil for remote relay trip. ● Auxiliary contacts for status signalling. ● Mechanical slide interlock. Approved to CBE standard EN 60934 (IEC 60934). 3120-F... Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02 Safety of household and similar electrical appliances. Technical data Typical applications For further details please see chapter: Technical Information Voltage rating AC 240 V; DC 50 V Motors, transformers, solenoids, extra low voltage wiring systems, office (AC 415 V to special order) machines, electro-medical equipment, power supplies, communications (UL: AC 250 V; DC 50 V) systems, industrial controls. Current ratings 0.1...20 A (up to 30 A to special order, single pole only) Standard current ratings and typical internal resistance values Typical life 1-pole AC 240 V: 0.1...20 A 30,000 operations at 1 x I , inductive N DC 50 V: 0.1...4 A 30,000 operations at 1 x I , inductive N Current Internal resistance Current Internal resistance 4.5...16 A 30,000 operations at 1 x I , resistive N rating (A) per pole (Ω) rating (A) per pole (Ω) DC 28 V: 4.5...20 A 30,000 operations at 1 x I , inductive N 0.1 94 4 0.0435 2-pole AC 415 V: 0.1...16 A 10,000 operations at 1 x I , inductive 0.2 24 4.5 0.0435 N AC 240 V: 0.1...16 A 50,000 operations at 1 x I , inductive N 0.3 12 5 0.0325 17...20 A 30,000 operations at 1 x I , inductive N 0.4 5.30 6 0.0215 DC 50 V: 0.1...16 A 50,000 operations at 1 x I , inductive N 0.5 4.20 7 0.0165 17...20 A 10,000 operations at 1 x I , inductive N 0.6 2.90 8 0.0165 Ambient temperature -30...+60 °C (-22...+140 °F) 0.8 1.50 10 < 0.02 Insulation co-ordination rated impulse pollution (IEC 60664 and 60664 A withstand voltage degree 1 0.9 12 < 0.02 2.5 kV 2 1.2 0.80 14 < 0.02 reinforced insulation in operating area 1.5 0.45 15 < 0.02 Dielectric strength 2 0.27 16 < 0.02 (IEC 60664 and 60664A) test voltage operating area AC 3,000 V 2.5 0.0785 18 < 0.02 between poles (2-pole) AC 1,500 V 3 0.0595 20 < 0.02 Insulation resistance > 100 MΩ (DC 500 V) 3.5 0.0565 Interrupting capacity I 0.1...2 A 10 x I cn N 2.5...20 A 250 A 2-pole, or 150 A 1-pole Interrupting capacity I U 2-pole N N Illumination voltage/power consumption (UL 1077) 0.1...2 A AC 250 V 200 A 2.5...3 A AC 250 V 1,000 A 3.5...8 A AC 250 V 2,000 A operating voltage power consumption 9...16 A AC 250 V 3,500 A Y + R G 18...20 A AC 250 V 5,000 A 12 V 2 mA 3.5 mA 0.1...20 A DC 50 V 1,000 A 24 V 2 mA 3.5 mA Degree of protection operating area IP40 48 V 2 mA 3.5 mA (IEC 60529/DIN 40050) terminal area IP00 115 V 0.9 mA 2.8 mA Vibration 8 g (57-500 Hz), ± 0.61 mm (10-57 Hz) 230 V 0.9 mA 2.8 mA to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 30 g (11 ms) to IEC 60068-2-27, test Ea Approvals Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Authority Voltage ratings Current ratings Humidity 240 hours at 95 % RH, VDE (EN 60934) AC 240 V; DC 28 V 0.1...20 A to IEC 60068-2-78, test Cab DC 50 V 0.1...20 A 2-pole DC 50 V 0.1...10 A 1-pole Mass approx. 33 g (double pole) UL, CSA AC 250 V; DC 50 V 0.1...20 A approx. 27 g (single pole) CCC AC 250 V; DC 50 V 0.1...20 A Issue B(211209) www.e-t-a.com 1 - 75 Thermal Overcurrent Circuit Breaker 3120-F... Ordering information Typical time/current characteristics Type No. single or double pole load 3120 push button switch/circuit breaker Mounting 0.1…2 A F snap in frame 10000 +60 °C Size of frame +140 °F 2 flange mounting, special frame for fitting splash cover +23 °C +73.4 °F 3 to fit mounting cut-out 50.5 x 21.5 mm (1.99 x 8.47 in) panel thickness 1 - 6.35 mm (.039 - .250 in) -30 °C 1000 1 -22 °F Number of poles 0 2-pole, unprotected, switch only 1 1-pole, thermally protected 2 2-pole, thermally protected 5 2-pole, thermally protected on one pole only (terminals 11,12k,12i) 100 6 1-pole, unprotected, switch only Mounting frame design F with 2 push buttons G with 1 push button (switch-on only) 10 Terminal configuration P7 blade terminals 2x2.8x0.8 mm (QC 2x.110) (terminals 12(k), 22(k), 11, 21), not for under voltage module, not for switch 1 H7 12(k), 22(k): blade terminals 2x2.8-0.8 (QC 2x.110) 11, 21: terminal screws, not for switch N7 as P7, but including shunt terminals 12(i) and 22(i) as blade terminals 2x2.8x0.8 mm (QC 2x.110) 0.1 not for under voltage module 12 46810 20 40 G7 as H7, but including shunt terminals 12(i) and 22(i) … times rated current as blade terminals 2x2.8x0.8 mm (QC 2x.110) 2.5…20 A Characteristic curve 10000 +60 °C T1 thermal, 1.01-1.4 I N +140 °F Q1 switch only, only for N7 or G7 terminals +23 °C Switch style/colour +73.4 °F D 1 push button (re-set only) -30 °C 1000 Z 1 push button (momentary switch) -22 °F 01X black 04X red 12X white translucent 19X green translucent 100 S 2 push buttons on/off GRX green translucent/red WRX white translucent/red WBX white translucent/black 10 Push button illumination (optional) G green LED, AC/DC Y yellow LED, AC/DC R red LED, AC/DC 1 Illumination voltage range (optional) 1 10 - 14 V AC/DC 2 20 - 28 V AC/DC 3 90 - 140 V AC 4 185 - 275 V AC 0.1 5 42 - 54 V AC/DC 12 46810 20 40 … times rated current Current ratings 0.1...20 A The time/current characteristic curve depends on the ambient temperature 3120 - F 3 2 F - N7 T1 - S GRX G 4 - 10 A ordering example prevailing. In order to eliminate nuisance tripping, please multiply the circuit 3120 - F 3 0 F - N7 Q1 - S ... . . - 20 A switch only breaker current ratings by the derating factor shown below. See also section Technical information. N.B. Ambient temperature °F -22 -4 +14 +32 +73.4 +104 +122 +140 Switch only versions must be specified with -N7 or -G7 terminals. °C -30 -20 -10 0 +23 +40 +50 +60 Terminals 12(k) and 22 (k) are not fitted. Derating factor 0.8 0.76 0.84 0.92 1 1.08 1.16 1.24 1 - 76 www.e-t-a.com Issue B(211209) Trip time in seconds Trip time in seconds Thermal Overcurrent Circuit Breaker 3120-F... Dimensions Internal connection diagrams 3120-F3.F-…-S… 2-pole, 2-pole, actuating force max. 35 N thermally protected on both poles thermally protected on one pole only OFF position optional illumination in ON position line line 11 21 11 21 54 25 .984 2.13 16.2 14.2 .638 .559 12(i) 22(i) 12(i) 22(i) 1 12(k) 22(k) 12(k) load load 1-pole, 2-pole, thermally protected unprotected line line 11 11 21 12(i) 12(k) 11 12(i) 22(i) 12(i) 22(i) load 10.7 3.5 3 12(k) .421 load .138 .118 21 15.5 .827 .610 41 blade terminals DIN 46244-C-Ms-S (QC 2x.110) 1.61 flat head screw ISO1580 M3.5x5-MS Installation drawing tightening torque max. 0.8 Nm 3120-F3.G-...-D... When installing the circuit breaker apply pressure on bezel only. OFF position optional illumination in ON position 54 25 operating area .984 2.13 16.2 14.2 .638 .559 12(i) 12(k) 11 7 7 8 7 10 12(i) 12(k) 11 .276 .276 .315 .276 .394 10.7 mounting area 3.5 3 .421 .138 .118 21 15.5 .827 .610 41 blade terminals DIN 46244-C-Ms-S (QC 2x.110) 1.61 Panel cut-out flat head screw ISO1580 M3.5x5-MS tightening torque max. 0.8 Nm water splash cover 3120-F3… - 0.4 3120-F2.F-... -.016 (see next page) retaining clip - 0.2 -.008 min. 2.5 panel min .098 max.R2 max .079 ±0.05 ±.002 cover +0.3 50.5 35.4 74 +.012 1.99 1.39 2.91 16.2 60±0.1 .638 2.36±.004 max. R0.3 max .012 t: metal min. 2 mm (.079 in.) 3120-F2… plastic min. 3 mm (.118 in.) ø3.2 60±0.15 +.006 .126 2.36 +0.5 PT-screw 50.5 R2 12(i) 12(k) 11 Typ K40 +.020 1.99 .079 ø4mm (.157 in.) 10.7 3 3.5 .421 .138 .118 21 15.5 .827 .610 41 blade terminals DIN 46244-C-Ms-S 1.61 (QC 2x.110) flat head screw ISO1580 M3.5x5-MS Edges of working parts: ISO 13715 tightening torque max. 0.8 Nm mm This is a metric design and millimeter dimensions take precedence ( ) inch Issue B(211209) www.e-t-a.com 1 - 77 15 .591 15 15 10 .394 .591 .591 10 10 4.5 .394 .394 .177 33 33 33 1.30 1.30 1.30 10.2 .402 10 10 10 .394 .394 .394 +0.2 1-6.35 26 +.008 .039-.250 1.02 10 .394 0.2 21.5+ t +.008 .846 +0.2 ø4.3 +.008 .169 15.5 .610 R3.5 .138 Thermal Overcurrent Circuit Breaker 3120-F... Accessories Insulated cover Rear terminal shroud black (IP64) Y 303 068 01 Y 304 275 01 2.5 .098 40.5 +0.5 1.59 1.75 20.5 -0.25 +.020 .807 .069 -.010 1 20 .787 Terminal adapter Y 303 862 01 4 .157 ø8 .315 Water splash cover, transparent (IP66) for style 3120-F2.F-... X 221 619 01 blade terminal DIN 46244-C-Ms-S consisting of (QC 2x.110) - retaining clip Y 306 551 01 - cover Y 306 001 01 Spacer for 3120-F3... 48 Y 303 675 01/02 1.89 58 2.28 50.5 1.99 ø8 .315 ø4.4 .173 * Y 303 675 01 suitable for * panel thickness < 2 mm (.079 in) * Y 303 675 02 suitable for panel thickness < 4 mm (.157 in) 60 Blanking piece in -F3 frame 2.36 Y 303 885 31 73 2.87 54 25 matt finish 2.13 .984 31 16.5 1.22 .650 41 21 1.61 .827 mm This is a metric design and millimeter dimensions take precedence ( ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 1 - 78 www.e-t-a.com Issue B(211209) 1 .039 13.5 .531 4 .157 0.9 .035 9 .354 22 3.7 .146 .866 28 1.10 33 1.30 36 1.42 34.4 .134 10 50 .394 1.97 35 25 16.5 1.38 .650 .984 +5 70 +.197 2.76 Auxiliary Contact Module X3120-S for circuit breaker 3120-F... Description Dimensions A module supplied factory fitted to type 3120-F to provide electrically separate changeover contacts which operate as the main contacts open/ wclose. Ideally suited to status signalling and sequence switching. Typical applications 1 Monitoring of the switching position of the circuit breaker or any 10 21 connected load. .394 .827 14 .551 blade terminals DIN 46244-A2.8-0.5-Ms (QC .110) Ordering information plated Type No. X3120 Module for type 3120 and type 3140 7.5 7.5 Function .295 .295 2 S auxiliary contact module .079 19.8 Contact configuration .780 0 change-over contact Terminal design 1 blade terminals 2.8 x 0.5 (QC .110), silver plated Internal connection diagram Contact rating AC DC (not approved) Voltage rating Current rating Voltage rating Current rating line 12 V 0.1...4 A 11 21 34 32 24 V 0.1...4 A A 10 V-250 V 0.1...4 A 60 V 0.1...1 A 110 V 0.1...0,5 A module mounted 220 V 0.1...0.25 A B 5 V-250 V 0.05...1 A 5 V-250 V 0.05...1 A 12(i) 22(i) 31 Supply condition M module mounted to circuit breaker 3120-... 12(k) 22(k) X3120 - S 0 1 A M ordering example load Approvals (complete circuit breaker/module assembly) Technical data Authority Voltage ratings Current ratings Voltage rating AC 250 V; DC 220 V VDE (EN 60934) AC 250 V; DC 28 V 0.05...4 A Current rating 0.1...4 A / 0.05...1 A UL, CSA AC 250 V 0.05...4 A Typical life 50,000 operations Ambient temperature -30...+60 °C (-22...+140 °F) Dielectric strength (IEC 60664 and 60664A) test voltage between main and auxiliary circuit AC 3,000 V Insulation resistance > 100 MΩ (DC 500 V) Vibration 6 g (type X3120-S...A) 8 g (type X3120-S...B) (57-500 Hz), ± 0.46 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 15 g (11 ms), type X3120-S...A 20 g (11 ms), type X3120-S...B to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 38 g (complete assembly) mm This is a metric design and millimeter dimensions take precedence ( ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. Issue B(211209) www.e-t-a.com 1 - 79 8.5 .335 25.5 1.00 U< U< U< 15° Undervoltage Release Module X3120-U...for circuit breaker 3120-F... Description Dimensions A module suitable for all double pole versions of type 3120-F to trip flat head screw M3.5x5-MS ISO1580 +0.1 41 the main switch/circuit breaker mechanism in the event of loss of for mains connection - 0.2 tightening torque max. 0.8 Nm +.004 voltage. When the voltage is restored the rocker switch must be reset 1.61 - .008 to reconnect the load, thereby avoiding the safety hazards associated with automatic re-starting of machinery. Note: Basic unit 3120-...-H7 or -G7: screw terminals necessary. 1 Typical applications Machines such as power tools, industrial equipment and domestic appliances where automatic restart after restoration of power could 6.6 10.7 be dangerous (EC Machinery Directive). .260 21 .421 blade terminal 21 .827 DIN 46244-A2.8-0.8 .827 (QC .110) 22 2 terminals 1 terminal Ordering information .866 X3120-U02… X3120-U01… 23.5 .925 Without terminal(s): X3120-U00… Type No. X3120 Module for type 3120 Function U undervoltage release module Internal connection diagrams Terminal design 00 standard (without separate connections) 01 1 blade terminal 2.8x0.8 (QC .110) X3120-U00… X3120-U01… X3120-U02… 02 2 blade terminals 2.8x0.8 (QC .110) Voltage ratings line line line line line 00 AC 230/240 V 50/60 Hz 11 21 11 A2s 21 11 A1 A2 21 01 AC 120 V 50/60 Hz 02 AC 100 V 50/60 Hz 03 DC 24 V Assembly status M module mounted to the circuit breaker 3120 12(i) 22(i) 12(i) 22(i) 12(i) 22(i) X3120 - U 00 00 M ordering example 12(k) 22(k) 12(k) 22(k) 12(k) 22(k) load load load Approvals (complete circuit breaker/module assembly) Technical data Authority Voltage ratings Voltage ratings AC 100; 120 V; 230/240 V 50/60 Hz DC 24 V VDE (EN 60934) AC 100...240 V; DC 24 V Voltage tolerance +10%/-15% UL, CSA AC 100...240 V; DC 24 V Current consumption approx. 2.5 mA Typical life 20,000 operations Release values 0.2 x U < U < 0.7 x U N N (at a rated voltage of AC 100 V the device may release at 70 V and must release at 20 V) Release delay t < 20 ms Latch-in values ≥ 85 % U N Ambient temperature -30...+60 °C (-22...+140 °F) Vibration 8 g (57-500 Hz) ± 0.61 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 30 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 48 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95% RH to IEC 60068-2-78, test Cab Mass approx. 53 g (complete assembly) mm This is a metric design and millimeter dimensions take precedence ( ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 1 - 80 www.e-t-a.com Issue B(211209) 33.5 1.32 7.6 .299 Remote Trip Module X3120-M... for circuit breaker 3120-F... Description Dimensions A module which adds remote trip capability to all versions of type 3120-F. A voltage applied across the coil, by means of an external sensor for example, will cause disconnection of the main switch/ circuit breaker mechanism. Typical applications 1 Electrical monitoring of safety systems, remote trip. Ordering information 10.7 18 Type No. .421 blade terminals .709 X3120 Module for type 3120 DIN 46244-C-Ms-S 21 14 (QC 2x.110) .827 Function .551 M magnetic relay trip module Style 2 magnetic remote trip coil Terminal design P7 blade terminals 2x2.8x0.8 (QC 2x.110) tin plated Internal connection diagram Supply condition M module mounted to the circuit breaker Voltage ratings line AC 12, 24, 48, 60, 120, 220, 230, 240 V 11 21 DC 12, 24 V X3120 - M 2 P7 M - 12 V ordering example 12(i) 22(i) 12(k) 22(k) load Standard voltage ratings and typical internal resistance values 12(n) FA remote trip Voltage Internal Voltage Internal module 12 mounted rating resistance per rating resistance per (V) pole (Ω) (V) pole (Ω) 12 V AC/DC 0.78 120 V AC 71.0 24 V AC/DC 3.3 220 V AC 312 Technical data 48 V AC 11.9 230 V AC 312 60 V AC 18.5 240 V AC 312 Voltage ratings AC 12...240 V; DC 12...24 V Power consumption approx. 200 W Pulse operation 20 ms < t < 100 ms/t > 10 sec ON OFF Approvals (complete circuit breaker/module assembly) Release delay t < 20 ms Typical life 50,000 operations at U N Authority Voltage ratings Ambient temperature -30...+60 °C (-22...+140 °F) VDE (EN 60934) AC 12...240 V; DC 12...24 V Dielectric strength UL, CSA AC 12...240 V; DC 12...24 V (IEC 60664 and 60664A) test voltage between main circuit and trip coil circuit AC 3,000 V Insulation resistance > 100 MΩ (DC 500 V) Vibration 8 g (57-500 Hz) ± 0.61 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 30 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 53 g (complete assembly) mm This is a metric design and millimeter dimensions take precedence ( ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. Issue B(211209) www.e-t-a.com 1 - 81 9 30 .354 1.18

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the 3120-F321-P7T1-W02D-20A?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...

product

MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...

product

Circuit Breaker Thermal 1Pole 2A 240VAC/28VDC

product

Circuit Breaker Thermal 1Pole 4A 240VAC/28VDC

product

Circuit Breaker Thermal 1Pole 0.2A 240VAC/48VDC 104-PR-0.2A

product

Circuit Breaker Thermal 1Pole 0.3A 240VAC/48VDC 104-PR-0.3A