E-T-A 410-K-2-02-100A
Specifications
Manufacturer
E-T-A
Manufacturers Part #
410-K-2-02-100A
Industry Aliases
410-K-2-02-100A
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
High Performance Thermal-Magnetic Circuit Breakers 410/520/530-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism and toggle actuation (S-type TM CBE to EN 60 934; also to EN 60 947). Designed for rail, panel or surface mounting. Available with a choice of characteristic curves and optional auxiliary contacts. Typical applications Motors, generators, transformers, thyristors and silicon rectifiers. 1 Interrupting capacity to IEC 60947/EN 60947 410-... 530-... AC voltage Number Voltage Interrupting Power Interrupting Power factor Technical data of poles rating capacity I factor capacity I N N I I N 12...125 A N 7 + 10 A Voltage rating AC 240 V; 3 AC 415 V; 3 AC 500 V 1 AC 240 V 5,000 A cosϕ = 0.7 3,500 A cosϕ = 0.8 DC 110 V 2 AC 240 V 8,000 A cosϕ = 0.7 6,000 A cosϕ = 0.7 Current rating range curves 01, 02, 04, 05: 10...125 A (EN 60947) 3 3 AC 415 V 5,000 A cosϕ = 0.7 3,000 A cosϕ = 0.85 curves B3, C3, 01: 7...100 A (EN 60898) DC voltage Auxiliary circuit 6 A, AC 240 V or DC 28 V Number Voltage Interrupting Time Interrupting Time con- 1 A, DC 110 V of poles rating capacity I constant capacity I stant N N Typical life 10,000 operations at 1 x I N I I N 12...125 A N 7 + 10 A 20,000 operations mechanical 1 DC 110 V 3,000 A 13 ms 3,000 A L/R = 5 ms Ambient temperature -40...+60 °C (-40...+140 °F) 1 DC 110 V 5,000 A 5 ms Insulation co-ordination rated impulse pollution (IEC 60664 and 60664A) withstand voltage degree 2 DC 110 V 5,000 A 13 ms 3,000 A L/R = 5 ms 6 kV 3 2 DC 110 V 10,000 A ≈ 0 ms Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,300 V pole/pole AC 3,300 V Standard current ratings and typical internal resistance values main circuit/aux.circuit AC 2,200 V aux. circuit 11-12/13-14 AC 1,000 V Curves 01, 02, 04, 05: Curves B3, C3: Insulation resistance > 100 MΩ (DC 500 V) Degree ef protection operating area IP40 Current Internal resistance Current Internal resistance (IEC 60529/DIN 40050) terminal area IP00 rating (A) (Ω) per pole rating (A) (Ω) per pole Vibration 10 0.033 7 0.033 curves 02, 04, 05, B3, C3: 4 g (60-500 Hz), ± 0.30 mm (10-60 Hz) 16 0.015 10 0.015 curve 01: 3 g (60-500 Hz), ± 0.23 mm (10-60 Hz) to IEC 60068-2-6, test Fc 20 0.010 12 0.015 10 frequency cycles/axis 25 0.0062 16 0.010 Shock curves 02, 04, 05, B3, C3: 50 g (11 ms) directions 1, 2, 3, 4, 5 32 0.0039 20 0.0062 30 g in direction 6 40 0.0031 25 0.0039 curve 01: 30 g (11 ms) in directions 1, 2, 3, 4, 5 20 g in direction 6 50 0.0022 32 0.0031 to IEC 60068-27, test Ea 63 ≤ 0.002 40 0.0022 Corrosion 96 hours at 5 % salt mist, 80 ≤ 0.002 50 ≤ 0.002 to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH 90 ≤ 0.002 63 ≤ 0.002 to IEC 60068-2-3, test Ca 100 ≤ 0.002 80 ≤ 0.002 Mass 410 (1-pole): approx. 290 g 125 ≤ 0.002 100 ≤ 0.002 520 (2-pole): approx. 580 g 530 (3-pole): approx. 870 g Approvals Authority Standard Rated voltage Current ratings UL UL 1077 AC 277 V 7...125 A (type 520) C22.2 No 235 1646 www.e-t-a.de 1 26° High Performance Thermal-Magnetic Circuit Breakers 410/520/530-... Ordering information Dimensions Type No. 410 single pole (ratings > 125 A: suffix 17015 - parallel connection) 520 double pole 530 three pole ON OFF Terminal design - main terminals K screw terminals 10-32 A pressure plate B5-DIN 46288 (curves B3/C3, 7-25 A) 40-63 A pressure plate B6-DIN 46288 (curves B3/C3, 32-63 A) Si terminals M3.5 80-125 A terminal screw DIN 46206, sheet 2, form 1, M6 thread 1 N/C Mounting 1 N/O 1 surface mounting 2 rail mounting (DIN EN 50022-35x7.5) or panel mounting 4 panel mounting with cylinder head screw M3.5 1 Magnetic trip curves 01 2.1-3 x I AC (thyristor and rectifier protection) N 02 7-10 x I AC (motor and generator protection to EN 60947) N 92 16 04 3.5-5 x I AC (cable protection to EN 60947) N 3.62 .630 05 4-6 x I AC (generator protection to EN 60947) N symmetrical rail DIN EN 50022-35x7.5 B3 3-5 x I AC (cable protection to EN 60898) N G profile rail DIN EN 50035-G32 (not shown) C3 5-10 x I AC (cable protection to EN 60898) N M3.5 - thread max. 9 mm (.354 in.) deep Auxiliary contacts optional (terminals M3.5) tightening torque max. 0.8 N D Si one each N/O and N/C contact 45 Si1 one N/C (11,12) 1.77 Current ratings 35 E 7...125 A 1.38 520 - K - 1 - 01 - ... - 10 A ordering example pole 1 The exact number required can be built up from the table of choices shown above. pole 2 Ordering references for optional features should be omitted if not required. B pole 3 Mounting methods Surface mounting rail mounting -1 (DIN EN 50 022-35x7,5) Current Dimensions mm/in. Terminal Cross section (see DIN 46288) -2 Max. rating tightening with 1 or 2 equal with 2 different B CD E torque conductors conductors pressure 2 2 13 114 7 2.5 mm to 2.5 mm to plate B5 2.0 Nm ≤ 32 A M5 2 2 .512 4.49 .276 10 mm 10 mm DIN 46288 2 2 pressure 2 4 mm and 6 mm 15.4 120 9 4 mm to plate B6 ≤ 63 A M6 2 or 2.5 Nm .606 4.72 .354 16 mm 2 2 DIN 46288 6 mm to 16 mm 15.4 120 9 terminal panel mounting ≤ 125 A M6 2.5 Nm .606 4.72 .354 screw -4 surface mounting 14.6 .575 monting holes 35 1.38 ø20 .787 3.7 22 ø4.6 .146 .866 .181 mm This is a metric design and millimeter dimensions take precedence ( ) inch 2 www.e-t-a.de 1646 26° 66 97 2.60 3.82 106 44 4.17 1.73 22 41 .866 1.64 3 6 .118 .236 71.5 2.82 90.5 3.56 4.6 +1 44 .181 +.039 1.73 +0,5 22 +.020 .866 C 19 .748 type 530 ø4 type 520 type 410 .157 High Performance Thermal-Magnetic Circuit Breakers 410/520/530-... High Performance Thermal-Magnetic Circuit Breakers 410/520/530-... Typical time/current characteristics at +23 °C/+73.4 °F Internal connection diagrams Type 410-K Type 410-K-Si Magnetic trip curves 01,02,04,05 1) AC/DC line 1 line 1 11 13 10000 1000 12 14 > > I I 100 2 2 10 1 Type 520-K-Si Type 530-K-Si 1 line 1 3 11 13 05 line 1 3 5 11 13 01 04 02 0.1 0.01 12 14 12 14 I > I > I > I > I > 0.001 12 46 8 10 20 40 60 80100 2 4 6 2 4 … times rated current Magnetic trip curves B3,C3 Shock directions 1) AC/DC 10000 4 1000 3 2 100 10 1 1 5 6 B3 C3 0.1 0.01 0.001 12 46 8 10 20 40 60 80100 … times rated current 1) Magnetic tripping currents are increased by 20% on DC supplies. 1646 www.e-t-a.de 3 Trip time in seconds Trip time in second s High Performance Thermal-Magnetic Circuit Breakers 410/520/530-... Accessories Splash cover (transparent), Terminal insulation cover for 410/520/530-... with fixing plate and screws (IP54) X 211 705 01 for type 410 (1 set = 2 pcs per pole) X 211 118 01 protected against brush contact * 53 2.09 40 38 1 1.50 1.57 24.5 protected against brush contact * .965 mounting hole +0.3 25 +.012 .984 165 6.50 * to DIN 57106T100/VDE 0106 T100 35 1.38 Splash cover (transparent), with fixing plate and screws (IP54) for type 520 X 211 119 01 53 2.09 38 1.50 24.5 59 .965 2.32 mounting hole +0.3 25 +.012 .984 35 1.38 mm This is a metric design and millimeter dimensions take precedence ( ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 4 www.e-t-a.de 1646 +0.3 59 1.2 21 ø4 1.2 21 .047 .157 .047 .827 .827 max. 4 +0.3 ø4 62 max. 4 40 44 max .157 +.012 1.73 .157 1.57 max .157 22 .866 ø10 64 19 2.52 .394 .748 44 92 3.62 1.73 94 3.70 +.012 2.32 2.44
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the 410-K-2-02-100A?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
Related Products

MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...

MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods