E-T-A 8340-F130-K3M2-A2H0-10A
Description
SINGLE AND MULTIPOLE MAGNETIC CIRCUIT BREAKERS WITH TRIP-FREE MECHANISM AND TOGGLE ACTUATION. A CHOICE OF FAST MAGNETIC ONLY OR HYDRAULICALLY DELAYED SWITCHING CHARACTERISTICS (S-TYPE MO OR HM CBE TO EN 60934) ENSURES SUITABILITY FOR A WIDE RANGE OF APPL
Part Number
8340-F130-K3M2-A2H0-10A
Price
Request Quote
Manufacturer
E-T-A
Lead Time
Request Quote
Category
Circuit Protection » Circuit Breaker
Specifications
Manufacturer
E-T-A
Manufacturers Part #
8340-F130-K3M2-A2H0-10A
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or HM CBE to EN 60934) ensures suitability for a wide range of applications. Industry standard dimensions and panel mounting. Options include auxiliary changeover contacts. Low temperature sensitivity at rated load. Approved to CBE standard EN 60934 (IEC 60934). Typical application 1 Control equipment, communications systems, transportation, power 8340-F... 1-pole 2-pole supplies. Standard current ratings and typical internal resistance values Technical data For further details please see chapter: Technical Information Current Internal resistance values (Ω) per pole rating (A) Voltage rating 3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V F1 F2 K1, M1, T1 K2, M2, T2 (higher DC ratings to special order) 0,02 1 493 953 2 669 2 457 Current ratings 0.02...50 A DC 0.02...30 A AC 0,05 276 152 452 376 Auxiliary circuit 6 A, AC 240 V; 0,1 58 37 100 94 3 A, DC 28 V 1 A, DC 65 V; 0,25 8,2 6,0 15,5 14,7 0.5 A, DC 80 V 0,5 2,3 1,47 3,9 3,2 Typical life 3 AC 415 V, AC 240 V: 0,75 0,98 0,63 1,65 1,56 0.02...30 A 6,000 operations at 1 x I , inductive N 1 0,58 0,35 0,95 0,90 10,000 operations at 1 x I , resistive N DC 80 V: 0.02...25 A 6,000 operations at 1 x I , inductive N 2 0,145 0,096 0,26 0,20 0.02...30 A 10,000 operations at 1 x I , resistive N 40 + 50 A 6,000 operations at 1 x I , resistive 2,5 0,096 0,061 0,15 0,15 N Ambient temperature -40...+85 °C (-40...+185 °F) 3 0,065 0,048 0,10 0,10 Insulation co-ordination rated impulse pollution 5 0,025 < 0,02 0,042 0,040 (IEC 60664 and 60664A) withstand voltage degree 2.5 kV 2 6 < 0,02 < 0,02 0,029 0,028 reinforced insulation in operating area 8 < 0,02 < 0,02 < 0,02 < 0,02 Dielectric strength (IEC 60664 and 60664A) 10 < 0,02 < 0,02 < 0,02 < 0,02 operating area test voltage AC 3,000 V Line to Load test voltage AC 1,500 V 12 < 0,02 < 0,02 < 0,02 < 0,02 pole to pole (2- and 3-pole) test voltage AC 1,500 V 15 < 0,02 < 0,02 < 0,02 < 0,02 main to auxiliary circuit test voltage AC 3,000 V switching to trip circuit test voltage AC 1,500 V 16 < 0,02 < 0,02 < 0,02 < 0,02 (version -X) 20 < 0,02 < 0,02 < 0,02 < 0,02 Insulation resistance > 100 MΩ (DC 500 V) 25 < 0,02 < 0,02 < 0,02 < 0,02 Interrupting capacity 6 x IN at AC; IEC 60934 - test sequence E 4 x IN at DC 30 < 0,02 < 0,02 < 0,02 < 0,02 Interrupting capacity I 0.02...20 A 25...30 A N 40 < 0,01 - < 0,01 - (UL 1077) AC: 1-pole AC 250 V/3,500A AC 250 V/3,500A 2-pole AC 250 V/3,500A AC 250 V/5,000A 50 < 0,01 - < 0,01 - 3-pole 3AC 250V/3,500A 3AC250V/5,000A DC: 1-pole 0.02...50 A DC 80 V/3,500 A 2-pole 0.02...30 A DC 80 V/3500 A Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 Vibration with toggle down: 10 g (57-2000Hz) ± 0.76 mm (10-57 Hz) at 0.9 x IN directions 1, 2, 3, 4, 5: 10 g (57-2000 Hz) at 1 x IN. Shock 100 g (11 ms) at 1 x IN, directions 1,2,3,4,5 100 g (11 ms) at 0.8 x IN, direction 6. Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 65 g per pole 1747 www.e-t-a.de 1 Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Ordering information Approvals Type No. Authority Standard Rated voltage Current ratings 8340 magnetic circuit breaker with toggle actuator AC 240/415 V 0.02 A…30 A VDE IEC / EN Mounting AC 240 V 0.02 A…30 A 60934 F flange mounting DC 80 V 0.02 A…50 A Configuration AC 250 V 0.02 A…30 A 1 with mounting nuts 6-32 UNC UL UL 1077 DC 80 V 0.02 A…50 A 4 with mounting nuts M3 DC 80 V 100 A (2 poles in 9 snap-in frame parallel) Number of poles 1 single pole protected AC 250 V 0.02 A…30 A CSA C22.2 No magnetic and 2 two pole protected DC 80 V 0.02 A…30 A 235 hydraulic magnetic delayed 3 three pole protected } AC 240/415 V 0.02 A…30 A Panel hardware CQC GB 17701 1 AC 240 V 0.02 A…30 A 0 without panel hardware DC 80 V 0.02 A…50 A Terminal design (main contact) K4 screw terminals M5 recommended for I > 20 A N AC 240 V 1 A…30 A (8340-F410) QPL MIL-C-55629 P1 blade terminals A6.3-0.8 mm (QC.250) (≤ 35 A) DC 50 V 1 A…30 A (8340-410) Sweden ) Characteristic curve * AC 240 V 1 A…30 A (8340-F420) Defence Characteristic curve, instantaneous: AC 240 / 415 V 1 A…30 A (8340-F430) Material F1 DC Admin. F2 AC 50/60 Hz Short delay: Internal connection diagrams K1 DC K2 AC 50/60 Hz Medium delay: 1-pole protected multipole M1 DC magnetic line 1 11(C) M2 AC 50/60 Hz Long delay: line 1 11(C) unit 1 T1 DC T2 AC 50/60 Hz 12(NC) 14(NO) Actuator colour/design I > 12(NC) 14(NO) A black, long toggle 2 I > K black, short toggle 11(C) 1 2 load Z black, without toggle, with slot (only 1-pole) unit 2 other colours to special order 1-pole protected Marking on actuator hydraulic-magnetic 12(NC) 14(NO) 0 without marking line 1 11(C) I > L I-O; ON-OFF N I-O; ON-OFF (IN on housing top) 2 load unit 3 Auxiliary contacts 12(NC) 14(NO) H0 without auxiliary contacts I > H1 with auxiliary contacts, gold-flushed 2 load H2 auxiliary contacts, gold-flushed on one pole only (multipole) Auxiliary contact function 4 1 change over contact Auxiliary contact terminal design 2 blade terminal 2.8-0.5 mm Current ratings 0.02...50 A 8340 - F 1 1 0 - P1 M1 - A L H1 4 2 - 30A ordering example ) * Other characteristic curves upon request (e.g. pulse delayed, for high inrush currents or capacitive loads) Preferred types Preferred types Standard current ratings (A) 1 2 3 5 8 10 12 16 20 25 30 40 50 8340-F410-P1K1-KNH0- x x x x x x x x x x x x x x x x x x 8340-F410-P1K1-KNH142- x x x x x x x x x 8340-F410-P1M1-KNH0- x x x x x x x x x 8340-F410-P1M1-KNH142- x x x x 8340-F410-K4K1-KNH0- 8340-F410-K4K1-KNH142- x x x x x x x x 8340-F410-K4M1-KNH0- x x x x 8340-F410-K4M1-KNH142- 2 www.e-t-a.de 1747 30° 30° 30° 30° 30° 30° Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Dimensions Flange mounting Configuration: F9 Configuration: F4 Actuator: long toggle Actuator: long toggle 5.5 .217 ON OFF ON OFF 1 2 43 1 4 3 2 1 50.8 19 50.8 2.00 .748 2.00 66 2.60 26.7 4.3 1.05 .169 42.2 1.66 27.4 Actuator: short toggle 1.08 Actuator: short toggle 5.5 .217 ON OFF ON OFF 1 2 43 Actuator: without toggle, with slot Actuator: without toggle, with slot ON OFF OFF ON 1 43 2 number of poles: 1-3 Pole 1 23 Applicable for nominal dimensions without direct tolerance indication: DIN ISO 286 ± IT13 number of poles: 1-3 pole:1 23 Cut-out dimensions max. panel thickness: 2 ± 0.1 mm or 4 ± 0.15 mm (snap-fit) 19 mounting thread M3 .748 ±0.2 57.6 or 6-32 UNC-2B ±.008 2.27 mounting depth max. 4.5 mm/.177 in. ±0.2 38.4 tightening torque max. 0.33 Nm Cut-out dimensions ±.008 1.51 max. panel thickness: 3 mm ±0.2 19.2 ±.008 .756 ±0.1 3.5 (M3) +0.1 4 -0.15 (6-32UNC) ±.004 .138 (M3) +.004 .157 (6-32UNC) -.006 Applicable for nominal dimensions without direct tolerance indication: DIN ISO 286 ± IT13 ±0.12 19.05 ±.005 .750 ±0.12 38.1 ±.005 1.50 mm This is a metric design and millimeter dimensions take precedence ( ) inch 1747 www.e-t-a.de 3 30° 30° 30° 30° 30° 30° ±0.1 26.7 ±.004 1.05 41.2 17.5 3.3 Ø15 1.62 .689 .130 .591 8.6 3.3 3.3 .339 5.3 .130 .130 .208 ±0.12 Ø16 ±.004 .630 ±0.1 42.2 ±.004 1.66 ±0.2 55.4 ±.008 2.18 19 41.2 14.4 5.6 .748 1.62 .567 .220 3 .118 Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Actuator configuration Terminal design / Dimensions Actuator design K4 screw terminals M5 number of poles: 1 - 3 tightening torque max. 1.2 Nm Configuration: F4 Actuator long 1 1 2 4 3 OFFOFF OFFOFF OFF OFF 0 0 0 0 0 0 16 A 16 A 16 A 9.4 6 38.8 .370 1.53 Actuator short .236 1 OFF P1 blade terminals OFF 0 0 16 A 16 A 1 2 4 3 number of poles: 1 - 3 Configuration: F9 6 38.8 Actuator long blade terminals 1.53 .236 DIN 46244-A6.3-0.8 OFF OFFOFF OFFOFF OFF 0 00 0 00 Auxiliary contacts 16 A 16 A 16 A 16 A 16 A 16 A number of poles: 1 1 2 Configuration: F4 / F9 11 14 12 Actuator: Z (black, without toggle, with slot) 10.2 17.9 .705 .401 5.1 OFF blade terminals OFF .200 DIN 46244-A2.8-0.5 16 A 16 A Shock directions / Mounting attitudes Installation drawing 3 4 2 1 Terminal design K Terminal design P blow out outlet CBE 5 operating area terminal (reinforced insulation) mounting area 6 area 2 4 .079 .157 8 8 .315 .315 29 29 42 42 1.65 1.65 1.14 1.14 blow out area (minuaturable on request) Trip time values indicated for front mounting on a vertical even surface mm This is a metric design and millimeter dimensions take precedence ( ) inch 4 www.e-t-a.de 1747 7 30 1.18 .276 7 1 .039 .276 30 2 .079 1.18 1 1 .039 .039 9.6 5 9.7 .378 .382 .197 14.5 .571 Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Typical time/current characteristics at 23 °C / +73.4 °F Curve F2 (instantaneous) for AC Curve F1 (instantaneous) for DC 10000 10000 1000 1000 100 100 10 10 1 1 0,1 0,1 1 0,01 0,01 0,001 0,001 05 12 3 46 79 81 10 11 2 05 12 3 46 79 81 10 11 2 … times rated current … times rated current Curve K1 (short delay) for DC Curve K2 (short delay) for AC 50/60 Hz 10000 10000 1000 1000 100 100 10 10 1 1 0,1 0,1 0,01 0,01 0,001 0,001 05 12 3 46 79 81 10 11 2 05 12 3 46 79 81 10 11 2 … times rated current … times rated current Curve M1 (medium delay) for DC Curve M2 (medium delay) for AC 50/60 Hz 10000 10000 1000 1000 100 100 10 10 1 1 0,1 0,1 0,01 0,01 0,001 0,001 05 12 3 46 79 81 10 11 2 05 12 3 46 79 8 10 11 12 … times rated current … times rated current Curve T1 (long delay) for DC Curve T2 (long delay) for AC 50/60 Hz 10000 10000 1000 1000 100 100 10 10 1 1 0,1 0,1 0,01 0,01 0,001 0,001 12 31 5 6 8 011 12 0 4 7 9 0 12 31 4 5 6 8 9 011 12 7 … times rated current … times rated current N.B. All curves will only be maintained if the escutcheon is mounted on a vertical surface. Ambient temperature or mounting side-by-side does not influence the trip curve, derating is not required. The breakers may trip in the event of current peaks < 0.003 sec. For these applications we offer a mechanical pulse delay – please enquire. Other characteristic curves upon request (e.g. pulse delayed, for high inrush currents or capacitive loads). 1747 www.e-t-a.de 5 Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Ø3.5 [.138] - M3 Ø4 [.157] - 6-32 UNC Ø3.5 [.138] - M3 Ø 3.5 [.138] - M 3 Ø17.1 [.673] Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F... Accessories Splash cover with mounting plate and screws for 8340-F1.. and 8340-F4 1 pole Y 303 565 01 16.7 mounting holes 2 .657 .079 1 .039 18 1 .708 2 pole for 8340-F4 mounting holes ±0.15 X 211 118 01 40.15 40 ±.006 1.58 2 1.57 .079 ±0.1 19.2 ±.004 .756 19 .748 2.2 .087 3 pole for 8340-F4 mounting holes X 211 119 01 ±0.15 59.15 2 ±.006 2.33 .079 57 19 2.24 .748 ±0.15 2.2 37.8 ±.006 .087 1.49 Toggle guard for 8340-F1.. and 8340-F4 Y 307 250 01 40 1.57 Ø 3.5 Ø .138 50.5 1.99 mm This is a metric design and millimeter dimensions take precedence ( ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 6 www.e-t-a.de 1747 ±0.15 Ø 25.15 ±.006 Ø .990 ±0.15 Ø 25.15 ±.006 Ø.990 30.7 37.9 37.9 1.20 1.49 1.49 17.7 21 .697 3.3 ±0.15 ±0.15 42.4 42.4 ±.006 1.670±.006 1.670 15.7 15.7 .618 .618 1.6 x 45° .063x45° 15.7 .618 ±0.15 42.4 ±.006 1.670
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the 8340-F130-K3M2-A2H0-10A?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...
MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...
Manufacturers



What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods