E-T-A 8340-G211-N1E1-A4H111-0.5A-U
Specifications
Manufacturer
E-T-A
Manufacturers Part #
8340-G211-N1E1-A4H111-0.5A-U
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S- type MO or HM CBE to EN 60934) ensures suitability for a wide range of applications. Convenient threadneck panel or plug-in mounting, and with a white push button indicator band showing clearly the tripped/off position. Available with auxiliary contacts (1 x N/O, 1 x N/C) for status signalling and fitted with an unprotected shunt tap terminal as standard. Approved to CBE standard EN 60934 (IEC 60934). Typical application 8340-G2... Control equipment, communications systems, power semiconductors. 1-pole 2-pole Standard current ratings and typical internal resistance values Technical data Current Internal resistance (Ω) per pole For further details please see chapter: Technical Information rating (A) curve curves curves Voltage rating 3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V -F4/F5 -E1/H1/R1 -E2/H2/R2 3 Current ratings 0.02...50 A single pole (40+50 A DC only) 0.02 583 2441 2449 0.02...30 A multipole 0.05 94 376 365 Auxiliary circuit 1 A, AC 240 V/DC 65 V 0.5 A, DC 80 V 0.08 35.8 148 144 Typical life 0.1 23 94 84 3 AC 415 V, AC 240 V: 0.15 9.9 39 38 0.02...30 A 6,000 operations at 1 x I , inductive N 0.2 5 30.5 22.4 10,000 operations at 1 x I , resistive N 0.3 2.44 9.9 9.7 DC 80 V: 0.02...25 A 6,000 operations at 1 x I , inductive N 0.02...30 A 10,000 operations at 1 x I , resistive N 0.5 0.79 3.16 3.1 40 + 50 A 5,000 operations at 1 x I , resistive N 0.75 0.39 1.55 1.51 Ambient temperature -40...+85 °C (-40...+185 °F) 1 0.25 0.79 0.77 Insulation co-ordination rated impulse pollution 1.25 0.15 0.58 0.56 (IEC 60664 and 60664A) withstand voltage degree 1.5 0.10 0.37 0.36 2.5 kV 2 reinforced insulation in operating area 1.75 0.083 0.30 0.29 Dielectric strength 2 0.059 0.20 0.24 (IEC 60664 and 60664A) test voltage 2.5 0.044 0.146 0.138 operating area AC 3,000 V 3 0.028 0.10 0.099 pole to pole (2 + 3-pole) AC 1,500 V 4 < 0.02 0.059 0.057 main to auxiliary circuit AC 1,500 V aux. circuit 11-12/23-24 AC 1,000 V 5 < 0.02 0.040 0.038 switching to trip circuit (-X) AC 1,500 V 6 < 0.02 0.026 0.026 Insulation resistance > 100 MΩ (DC 500 V) 8 < 0.02 < 0.02 < 0.02 Interrupting capacity I 1,200 A at AC; 2,000 A at DC cn 10 < 0.02 < 0.02 < 0.02 Interrupting capacity I 0.02...20 A 25...30 A N 12 < 0.02 < 0.02 < 0.02 (UL 1077) AC: 1-pole AC 250 V/3,500A AC 250 V/3,500A 15 < 0.02 < 0.02 < 0.02 2-pole AC 250 V/3,500A AC 250 V/5,000A 3-pole 3AC 250V/3,500A 3AC250V/5,000A 16 < 0.02 < 0.02 < 0.02 DC: 1-pole 0.02...50 A DC 80 V/3,500 A 20 < 0.02 < 0.02 < 0.02 2-pole 0.02...30 A DC 80 V/3500 A 25 < 0.02* < 0.02 < 0.02 Interrupting capacity 30 < 0.02* < 0.02 < 0.02 (UL 489A) 2000 A 40 < 0.02 Degree of protection operating area IP40 50 < 0.02 (IEC 60529/DIN 40050) terminal area IP00 * 50 % ON duty / 60 min. Vibration with button down: 10 g (57-2000 Hz), ±0.76 mm (10-57 Hz) at 0.9 x I N other mounting planes: 10 g (57-2000 Hz) at I N Approvals to IEC 60068-2-6, test Fc 10 frequency cycles/axis Authority Voltage ratings Current ratings Shock 100 g (11 ms) at 1xI , directions 1,2,3,4,5 N 100 g (11 ms) at 0.8 x I , direction 6 VDE (EN 60934) 3 AC 415 V; AC 240 V; DC 80 V 0.02...30 A N to IEC 60068-2-27, test Ea DC 80 V 0.02...50 A 1-pole Corrosion 96 hours at 5 % salt mist, UL 1077, CSA DC 80 V 0.02...50 A 1, 2-pole to IEC 60068-2-11, test Ka 3 AC 250 V; AC 250 V 0.02...30 A 1,2,3-pole Humidity 240 hours at 95 % RH UL 489 A DC 80 V 0.05...30 A 1, 2-pole to IEC 60068-2-3, test Ca CCC 3 AC 415 V; AC 240 V; DC 80 V 0.02...30 A DC 80 V 0.02...50 A 1, 2-pole Mass approx. 70 g per pole 06/07(091106) www.e-t-a.com 3 - 7 5 Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Ordering information Dimensions (1-pole) Type No. 8340 Magnetic push/pull circuit breaker Terminal design -N Mounting tightening torque max. 4 Nm ø10.6 M12x1 G threadneck panel mounting .417 Threadneck design ø8.4 2 M12x1 .331 black Number of poles (main current paths) white 0 single pole, switch only 1 single pole, protected 2 two pole, protected 3 three pole, protected 5 two pole, protected on one pole only Panel hardware 0 without panel hardware 1 with hex nut M12x1 and washer 12/15 Terminal design 1 11 23 2(i) 24 12 2(k) P1 blade terminals A6.3-0.8mm (QC.250) N1 blade terminals A6.3-0.8mm (QC.250) with -A3 4.6 6.8 terminal (blade terminal) A6.3-0.8mm (QC.250) .181 6x6.8 .268 blade terminal A6.3-0.8 G3 screw terminals M4* with -A3 terminal (blade 6x.268 (QC .250) to DIN 46244 } G4 screw terminals M5* terminals) A6.3-0.8mm (QC.250) 45 1.77 K3 screw terminals M4* Terminal design -G/-K Terminal design -R K4 screw terminals M5* 3 R1 round connectors ø6 X1 blade terminals A6.3-0.8mm (QC.250), terminal M4 or M5 tightening torque separate switching and trip circuit max.1.2 Nm Characteristic curve F4 instantaneous trip: magn. 1.5-2.2xI DC (I ≤30 A) N N F5 magn.1.2-1.7xI AC 50/60 Hz (I ≤30A) N N E1 short delay: magn.-hydr. 1.01-1.4 I , DC 6.8 N 4.6 .268 E2 short delay: magn.-hydr. 1.01-1.4 I , AC 50/60 Hz .181 N 6x6.8 6x.268 H1 medium delay: magn.-hydr. 1.01-1.4 I , DC N 34 45 H2 medium delay: magn.-hydr. 1.01-1.4 I , AC 50/60Hz N 1.34 1.77 blade terminal A6.3-0.8 55.2 R1 long delay: magn.-hydr. 1.01-1.5 I , DC N (QC .250) to DIN 46244 2.17 R2 long delay: magn.-hydr 1.01-1.5 I , AC50/60Hz N current rating in A location pin for 3mm (.118 in.) Actuator colour mounting hole hole dia. SW14 A black with white trip indicator band ±0.2 9.5 .551 Actuator marking ±.008 .374 0 without marking 4 rated current (legible with location pin above) standard 0.8 7 rated current .031 (legible with location pin below) 9.5 .374 Auxiliary contacts 50 H0 without auxiliary contacts panel thickness 1.97 max. 3 mm (.118 in.) H1 with auxiliary contacts +0.2 ø12.5 H2 with auxiliary contacts * min. 25 for use with splash cover +.008 .492 on pole 1 only (2 and 3-pole types) H3 with auxiliary contacts on poles 1 and 3 (3-pole type) Auxiliary contact function 1 one each N/O and N/C 2 1 pair N/O (23/24) 3 1 pair N/C (11/12) Auxiliary contact terminal design 1 blade terminals A6.3-0.8 mm Current ratings (optional) 0.02...50 A Approval (optional) U UL 489 A 8340 - G 2 1 1 - N1 F4 - A 4 H1 1 1 - 8 A - U ordering example *M4 thread recommended for I > 20 A N M5 thread for I > 40 A N mm This is a metric design and millimeter dimensions take precedence ( ) inch 3 - 8 www.e-t-a.com 06/07(091106) 57.5 10 10 .394 19 .394 2.26 1.5 1.5 6.5 .748 .059 .059 .256 12.5 ON .492 2.7 18.2 OFF .106 .717 1.5 .059 3 19.4 * .764 .118 22.5 .886 +0.2 ø3 +.008 19.5 .118 .768 Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Dimensions (2-pole) Dimensions (3-pole) Internal connection diagrams 38 57 1-pole, protected magnetically multipole 1.50 2.24 11 23 line 1 11 23 line 1 unit 1 2(i) 12 24 2(i) 12 24 2(k) > > I I 2(k) 2(k) 111 23 1-pole, protected hydraulic-magnetically unit 2 line 1 11 23 2(i) 12 24 > I 2(k) unit 1 2(i) 12 24 111 23 > I 2(k) unit 3 unit 1 unit 2 unit 3 unit 2 2(i) 12 24 Circuit variants 1-pole > I line 1 23 min. 40 Cut-out dimensions: 2(k) 3 min. 1.57 8340-G211-X1F4-A4H121-…A 2-pole 1 - 11 switching circuit 11 24 2(i) - 2(k) magnetic trip circuit 2(i) 23 - 24 auxiliary circuit (N/O) panel thickness > I min. 60 max. 3 mm (.118 in) 2(k) min. 2.36 line 1 11 3-pole 8340-G211-X1F4-A4H131-…A 23 12 1 - 23 switching circuit 2(i) - 2(k) magnetic trip circuit 2(i) 11 - 12 auxiliary circuit (N/C) I > 2(k) Installation drawings Shock directions / Mounting attitudes Terminal design -N / -P Terminal design -G / -K 4 1 2 3 operating area mounting terminal area 6 (reinforced insulation) area 29 1.14 5 10 29 1.14 8 .394 2 .079 .315 Terminal design -R 25 .984 mm This is a metric design and millimeter dimensions take precedence ( ) inch 06/07(091106) www.e-t-a.com 3 - 9 5 .197 5 3.5 .197 .138 24 .945 5 .197 Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Typical time/current characteristics Curve F4 for DC, magnetic (undelayed) Curve F5 for AC 50/60 Hz, magnetic (undelayed) (I >20 A, 50% ON period, 60 min.) at +23 °C / +73.4 °F (I >20 A, 50% ON period, 60 min.) at +23 °C / +73.4 °F N N 10000 10000 1000 1000 100 100 10 10 1 1 0.1 0.1 0.01 0.01 0.001 0.001 0 12 3 4 5 6 7 8 9 10 11 12 0 12 3 4 5 6 7 8 9 10 11 12 … times rated current … times rated current Short delay curves E1 for DC and E2 for AC 50/60 Hz, Medium delay curves H1 for DC and H2 for AC 50/60 Hz, hydraulic-magnetic hydraulic-magnetic 3 10000 10000 1000 1000 100 100 10 10 1 1 0.1 0.1 0.01 0.01 0.001 0.001 0 12 3 4 5 6 7 8 9 10 11 12 0 12 3 4 5 6 7 8 9 10 11 12 … times rated current … times rated current Long delay curves R1 for DC and R2 for AC 50/60 Hz, hydraulic-magnetic 10000 1000 100 10 1 0.1 N.B. Curves E1, E2, H1, H2, R1 and R2 will only be maintened if 0.01 the escutcheon is mounted on a vertical surface. 0.001 0 12 3 4 5 6 7 8 9 10 11 12 Other curves upon request ( e. g. impulse delay). … times rated current 3 - 10 www.e-t-a.com 06/07(091106) Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Accessories Socket Polarized socket with Hex nut Spring washer 18-P10-Si adapter Y 300 116 02 Y 300 118 03 (for ratings >16 A please contact E-T-A) 18-P10-Si-20025 +0.2 ±0.5 M12x1 1.2 ø12 retaining clip blade terminal A6.3-0.8 (QC .250) +.008 ±.020 .047 .472 (accessory) to DIN 46244 polarized to ensure correct connection 10 10 mm .394 in. .394 depth thickness SW14 2.5 ø15 0.4 mm .551 .098 .016 in. .591 19 80 Accessories for push button .748 3.15 Splash cover with hex nut and O ring (IP66) top-hat rail adapter X 200 409 01 EN 50022-35x7.5 X 200 801 08 (nickel plated hex nut M12x1, splash cover transparent) G profile X 200 801 03 (black finish hex nut M12x1, polarization recess EN 50035-G32 splash cover black) Bus bar (10-way) (supplied as a complete package) for type 18 socket (for max. 100 A continuous load), more positions available on request X 211 158 01 with terminal X 211 158 02 without terminal 3 SW 17 Phoenix terminal AKG 35 cylinder-head screw washer 2 cross section max 35 mm (AWG 2) M4x4 ISO 1207 nickel-plated A4.3 DIN 125 nickel plated M12x1 Splash seal, black, hex nut and O ring (IP54) X 200 802 01 (nickel plated hex nut M12x1, female connector splash seal black) copper rail M4 7 tin-plated SW 17 .276 19 .748 Actuator extension 223 X 200 803 01 (black button) 8.78 fusible link (constriction 1 mm/.039 in. thick) Insulated sleeving for bus bars Y 303 824 11 9 .354 5.4 190 .213 7.48 Retaining clip for socket 18-P10-Si Y 300 579 11 52 2.05 60 2.36 mounting dimensions 35 1.38 Connector bus link -P10 2 X 210 588 01/1.5 mm (AWG 16), brown (up to 13 A max. load) 2 X 210 588 02/2.5 mm (AWG 14), black (up to 20 A max. load) 2 X 210 588 03/2.5 mm (AWG 14), red (up to 20 A max. load) 2 X 210 588 04/2.5 mm (AWG 14), blue (up to 20 A max. load) 100 quick-connect tabs 6.3 (.250) DIN 46247 tinned brass, insulated mm This is a metric design and millimeter dimensions take precedence ( ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 06/07(091106) www.e-t-a.com 3 - 11 25.8 6.5 4 2 .256 .157 1.02 .079 3.5 .138 10 ~70 .394 ~2.76 ø1 15 .039 .591 33.3 1.31 1.4 .055 8 55.5 5 2.19 .315 .197 10 .394 45.8 1.80
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the 8340-G211-N1E1-A4H111-0.5A-U?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...
MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...
Manufacturers




What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods