E-T-A 8345B23AU3M2DB1B2B30A
Specifications
Manufacturer
E-T-A
Manufacturers Part #
8345B23AU3M2DB1B2B30A
Lead Time
9 Week Lead Time
Industry Aliases
8345-B23A-U3M2-DB1B2B-30A
Sub-Category
Circuit Breakers
Factory Pack Quantity
1
Datasheet
Extracted Text
Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free- mechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications. Industry standard dimensions and panel mounting. Auxiliary contacts optional. Low temperature sensitivity at rated load. Approved to CBE standard EN 60934 (IEC 60934) S-type HM CBE. Typical applications In the business fields Communication and Transport: power supplies, switchgear, instrumentation and process control engineering. 1 8345 1-pole 2-pole Standard current ratings and typical internal resistance values Technical data Current Trip curves and internal resistance (Ω) per pole rating (A) F1 F2 K1, M1, T1 K2, M2, T2 Voltage rating 3 AC 415 V; AC 277/480 V; 0,05 AC 120/240 V; AC 240 V; DC 80 V --- --- 531 542 (higher DC voltages to special order) 0,1 --- --- 129 127 Current rating range 0.02...125 A single and multipole 1 0,578 0,347 1,10 1,08 higher ratings upon request 2 Auxiliary circuit AC 240 V 6 A 0,144 0,0959 0,295 0,291 DC 28 V 3 A 3 0,0644 0,0477 0,121 0,118 DC 65 V 1 A 5 DC 80 V 0.5 A 0,0250 0,0192 0,0437 0,0449 Typical life 10,000 operations at 1 x I 10 N 0,00901 0,00714 0,0147 0,0133 Ambient temperature -40...+85 °C (-40...+185 °F) 15 0,00597 0,00483 0,00794 0,00794 Insulation co-ordination 20 0,00468 0,00410 0,00597 0,00597 (IEC 60664) 2.5 kV/2 25 reinforced insulation in operating area 0,00410 0,00385 0,00456 0,00456 Dielectric strength 30 0,00385 0,00371 0,00458 0,00458 operating area test voltage AC 3,000 V 40 0,00371 0,00371 0,00373 0,00373 Line to Load test voltage AC 1,500 V pole to pole (2- and 3-pole) test voltage AC 1,500 V 50 0,00358 0,00358 0,00335 0,00335 main to auxiliary circuit test voltage AC 3,000 V 60 --- --- 0,00333 0,00333 switching to trip circuit test voltage AC 1,500 V (version -X) 80 --- --- 0,00325 0,00325 Insulation resistance > 100 MΩ (DC 500 V) 100 --- --- 0,00316 0,00316 Degree of protection operating area IP40 125 --- --- 0,00314 0,00314 (IEC 60529) terminal area IP00 Vibration mounting attitude 10 g (57-2000 Hz) ± 0,76 mm (10-57 Hz) to EN 60934, CCC, UL 489, UL 1077 Interrupting capacity toggle down: at 0.9 x I N other mounting attitudes: 10 g at 1 x I N IEC 60934 / CCC (3-pole) – test series E: with curves F1, F2: 10 g at 0.8 x I in all mounting attitudes N (57-2000 Hz) ± 0.76 mm (10-57 Hz) voltage number of I max. (A) I (A) N cn to IEC 60068-2-6, test Fc poles 10 frequency cycles/axis DC 80 V 1 + 2 0.02...125 10 000 Shock directions 1, 2, 3, 4, 5: 100 g (11 ms) at 1 x I , AC 240/415 V 1 – 4 0.016...80 6 x I N N direction 6: 100 g (11 ms) at 0.8 x I , N AC 240 V 1 0.016...20 5 000 with curves F1, F2: 100 g (11 ms) at 0.8 x I N to IEC 60068-2-27, test Ea UL 489 – test sequence Z: Corrosion 96 hours at 5 % salt mist, voltage number of I max. (A) I (A) N cn to IEC 60068-2-11, test Ka poles Humidity 240 hours at 95 % RH, DC 80 V 1 + 2 0.5...125 10 000 to IEC 60068-2-78, test Cab Mass approx. 90 - 120 g per pole AC 120 V 1 0.5...80 5 000 depending on version AC 120/240 V 1 (2) 0.5...80 5 000 AC 240 V 1 0.5...20 5 000 UL 1077: voltage number of I max. (A) I (A) N cn poles DC 80 V 1 + 2 0.02...125 10 000 AC 277/480 V 1 – 4 0.02...70 5 000 1801 www.e-t-a.de 1 Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Ordering information for EN 60934 and UL 1077 Type No. Ordering information for auxiliary contact module 8345 Mounting Type number B flange mounting, with rectangular aperture with mounting nut 6-32UNC X8345 C flange mounting, with rectangular aperture with mounting nut M3 Module F flange mounting, with round aperture with mounting nut M3 S auxiliary contact module Configuration Auxiliary contacts 0 without barrier 01 in all poles 1 with small barrier 02 in pole 1 only 2 with large barrier (requested for multipole AC applications) Auxiliary contact version Number of poles K auxiliary contacts (symmetrical terminals) 1 single pole protected Auxiliary contact function 2 two pole protected 1 W1 1 changeover 3 three pole protected Terminal design 4 four pole protected 02 microswitch with blade terminals Actuator configuration DIN 46244-A2.8-0.5 A all poles with standard toggle M mounted to base unit B reduced number of standard toggles Z without actuator X8345 - S 01 K W1 02 M ordering example Terminal design P blade terminals ≤ 35 A R round connectors 6 mm Approvals U stud terminals M6 ≤ 125 A V stud terminals 1/4-20UNC-3A ≤ 125 A W laminated round terminals ≤ 125 A Authority Standard Rated voltage Current ratings Terminal hardware AC 240/415 V 0.016 A…80 A 0 without VDE IEC / EN AC 240 V 0.016 A…80 A 3 with washer and nut 60934 ) DC 80 V 0.02 A…125 A Characteristic curve * Characteristic curve, instantaneous: AC 277/480 V 0.02 A…70 A UL UL 1077 F1 DC (limited to ratings of 1 A to 50 A) AC 277 V 0.02 A…70 A C22.2 No F2 AC 60/50 Hz (limited to ratings of 1 A to 50 A) DC 80 V 0.02 A…125 A 235 Short delay: AC 120/240 V 0.05 A…80 A (2 pole) K1 DC UL UL 489 AC 240 V 0.05 A…20 A (1 pole) K2 AC C22.2 AC 120 V 0.05 A…80 A (1 pole) Medium delay: No 5 DC 80 V 0.05 A…125 A (1+2 pole) M1 DC M2 AC 60/50 Hz AC 240/415 V 0.02 A…80 A (3 pole) CQC GB Long delay: AC 240 V 0.02 A…80 A (1 + 2 pole) 17701 T1 DC DC 80 V 0.02 A…125 A (1 + 2 pole) T2 AC 60/50 Hz DC 110 V 0.05 A…125 A (1 + 2 pole) Version D standard Colour configuration B1 black actuator Marking front plate actuator base B1 without ON-OFF B2 I ON-OFF N Rated voltage B AC or ≤ 80 V DC Current ratings 0.02...125 A higher current ratings upon request 8345 - C 0 1 A - U 3 M1 - D B1 B1 B - 60 A ordering example Remote trip coil available to special order. ) * Other characteristic curves upon request (e.g. pulse delayed, for high inrush currents or capacitive loads) Note: Move actuator of multipole devices slowly and smoothly into ON position to ensure reliable latch-on behaviour of all poles. 2 www.e-t-a.de 1801 Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Ordering information for UL 489 Type No. Ordering information for auxiliary contact module 8345 Mounting Type number B flange mounting, with rectangular aperture with mounting nut 6-32UNC X8345 C flange mounting, with rectangular aperture with mounting nut M3 Module F flange mounting, with round aperture with mounting nut M3 S auxiliary contact module Configuration Auxiliary contacts 0 without barrier for DC 01 in all poles 1 with small barrier for DC (optional) 02 in pole 1 only 2 with large barrier for AC Auxiliary contact version Number of poles K auxiliary contacts (symmetrical terminals) 1 single pole protected Auxiliary contact function 2 two pole protected 1 W1 1 changeover Actuator configuration Terminal design A all poles with standard toggle 02 microswitch with blade terminals B reduced number of standard toggles DIN 46244-A2.8-0.5 Z without actuator M mounted to base unit Terminal design P blade terminals ≤ 35 A X8345 - S 01 K W1 02 M ordering example R round connectors 6 mm U stud terminals M6 ≤ 125 A V stud terminals 1/4-20UNC-3A ≤ 125 A W laminated round terminals ≤ 125 A Terminal hardware 0 without 3 with washer and nut ) Characteristic curve * Characteristic curve, instantaneous: F1 DC (limited to ratings of 1 A to 50 A) F2 AC 60/50 Hz (limited to ratings of 1 A to 50 A) Short delay: K1 DC K2 AC Medium delay: M1 DC M2 AC 60/50 Hz Long delay: T1 DC T2 AC 60/50 Hz Version D standard Colour configuration B1 black actuator Marking front plate actuator base B1 without ON-OFF B2 I ON-OFF N Rated voltage B AC or ≤ 80 V DC Current ratings 0.05...125 A for DC 0.05...20 A for AC higher current ratings upon request Approvals (optional) V UL 489 8345 - C 0 1 A - U 3 M1 - D B1 B1 B - 60 A - . ordering example Remote trip coil available to special order. ) * Other characteristic curves upon request (e.g. pulse delayed, for high inrush currents or capacitive loads) 1801 www.e-t-a.de 3 F F F F F F F F F F F F F F F F Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Dimensions Installation drawing 8 29 Mounting version B/C .315 1.14 number of poles 1 to 4 Flange mounting rectangular aperture blow out space pole 12 34 (can be reduced on request) 48 ±0.1 19.1 1.89 ±.004 .752 ON OFF 1 68 2.68 mounting thread M3 or 6-32 all dimensions referred to the top edge 2 mounting depth 4.2 mm/.165 in. terminal operating area .079 max. insertion depth 5.5 mm area (reinforced insulation) mounting max. tightening torque 0.33 Nm area Cut-out dimensions: 1-pole multipole 76.5 3.01 66.9 19.2 2.63 .756 47.8 1.88 9.6 ±0.1 3.5 (M3) .378 19.1 n x 19.1 +0.1 4 (6-32UNC) -0.15 .752 n x .752 ±.004 .138 (M3) 28.7 +.004 .157 (6-32UNC) -.006 1.13 Mounting version F number of poles 1 to 4 Flange mounting round aperture pole 12 34 ±0.1 19.1 48 ±.004 .752 1.89 ON OFF 68 mounting thread M3 or 6-32 2.68 all dimensions referred to the top edge mounting depth 4.2 mm/.165 in. max. insertion depth 5.5 mm max. tightening torque 0.33 Nm Cut-out dimensions: 1-pole ±0.1 3.5 (M3) +0.1 4 (6-32UNC) -0.15 4-pole ±.004 .138 (M3) +.004 .157 (6-32UNC) -.006 19.1 n x 19.1 max. panel thickness: 3 mm .752 n x .752 mm This is a metric design and millimeter dimensions take precedence ( ) inch 4 www.e-t-a.de 1801 O O O O O O O O 52.4 ø15.4 2.06 28.6 .606 28.6 11 36.8 1.13 1.13 1.45 .433 15.45 .608 ø4 44.75 LOADLINE LOADLINE .157 1.76 63.5 63.5 2.50 2.50 ø15.4 .606 45 1.77 1 2 .039 .079 Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Terminal design / Dimensions Internal connection diagrams P - with blade terminals 1-pole multipole 49.2 protected magnetically 1.94 11(C) line 1 11(C) line 1 unit 1 LOAD LINE 12(NC) 14(NO) 12(NC) 14(NO) I > I > blade terminal A6.3-0.8 (QC .250) DIN 46244 2 (load) 2 (load) 11(C) line 1 R - round connectors unit 2 D = 6 mm 1-pole protected 1 hydraulic-magnetically line 1 11(C) 12(NC) 14(NO) I > 2 (load) LOAD LINE unit 3 unit 4 12(NC) 14(NO) I > 49.2 2 (load) 1.94 W - laminated round terminals LOAD LINE plug-in hole ø6.3 +0.1 6.3 ø.248 +.004 .248 49.2 1.94 cylindrical terminal area U/V stud terminals with auxiliary contacts LOAD LINE NC NO C NC NO C 7.5 7.5 .295 .295 17.5 16.6 .689 .653 auxiliary contact tightening torque: module (change over) 10-32 UNF. M5 max. 2 Nm 1/4-20 UNC. M6 max. 3 Nm mm This is a metric design and millimeter dimensions take precedence ( ) inch 1801 www.e-t-a.de 5 9.5 17 .374 12.2 .480 5 .197 19.2 17 27.6 .669 .756 1.09 . . . . . . Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Typical time/current characteristics at +23 °C / +73.4 °F Curve F2 (instantaneous) for AC Curve F1 (instantaneous) for DC 10000 10000 1000 1000 100 100 10 10 1 1 0,1 0,1 1 0,01 0,01 0,001 0,001 05 12 3 46 79 81 10 11 2 05 12 3 46 79 81 10 11 2 … times rated current … times rated current Curve K1 (short delay) for DC Curve K2 (short delay) for AC 50/60 Hz 10000 10000 1000 1000 100 100 10 10 1 1 0,1 0,1 0,01 0,01 0,001 0,001 05 12 3 46 79 81 10 11 2 05 12 3 46 79 81 10 11 2 … times rated current … times rated current Curve M1 (medium delay) for DC Curve M2 (medium delay) for AC 50/60 Hz 10000 10000 1000 1000 100 100 10 10 1 1 0,1 0,1 0,01 0,01 0,001 0,001 05 12 3 46 79 81 10 11 2 05 12 3 46 79 8 10 11 12 … times rated current … times rated current Curve T1 (long delay) for DC Curve T2 (long delay) for AC 50/60 Hz 10000 10000 1000 1000 100 100 10 10 1 1 0,1 0,1 0,01 0,01 0,001 0,001 12 31 4 5 6 7 8 9 011 12 0 0 12 31 4 5 6 7 8 9 011 12 … times rated current … times rated current N.B. All curves will only be maintained if the escutcheon is mounted on a vertical surface. Ambient temperature or mounting side-by-side does not influence the trip curve, derating is not required. The breakers may trip in the event of current peaks < 0.003 sec. For these applications we offer a mechanical pulse delay – please enquire. Other characteristic curves upon request (e.g. pulse delayed, for high inrush currents or capacitive loads). 6 www.e-t-a.de 1801 Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds Trip time in seconds F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Actuator configuration Accessories A 1 toggle per pole, mounting version B/C Splash cover (IP65) for 1-, 2-, 3-pole (only for mounting version B/C) number of mounting actuator poles version configuration X 222 444 01 1-pole B 1 X 222 444 02 1-pole C 1 X 222 444 11 2-pole B 2 X 222 444 12 2-pole C 2 X 222 444 21 3-pole B 3 B reduced number of toggles per unit, mounting version B/C X 222 444 22 3-pole C 3 panel thickness max. 3 mm 1 ON ON A 1 toggle per pole, mounting version F 35 9,5 56.5 1.38 2.22 0.374 22.25 .876 ON B reduced number of toggles per unit, mounting version F 74 2.91 Z without toggles version B/C Toggle guard (only for mounting version B/C) Y 307 381 01 64 2.52 37.3 16.7 Z without toggles, mounting version F 1.47 .657 ø4 .157 52.4 2.06 Interphase barriers / Dimensions Shock directions 1 - Interphase barrier 2 - Interphase barrier (small) 4 (large) 2 3 1 6 LOAD LINE LOAD LINE 5 75 100 3.94 2.95 thickness 1mm / .039 in. mm This is a metric design and millimeter dimensions take precedence ( ) inch 1801 www.e-t-a.de 7 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O LINE LOAD 31.5 1.24 76 2.99 70 2.75 76 2.99 19.2 .756 2.8 .110 67.5 2.66 19.6 .772 52.4 2.05 Remote trip module X8345-F for Circuit Breaker 8345-... Description Dimensions A module which adds remote trip capability to all versions of type 8345. A voltage applied across the coil, by means of an external sensor for Additional remote trip module example, will cause disconnection of the main switch/circuit breaker mechanism. LOAD LINE Typical applications Electrical monitoring of safety systems, remote trip. 1 Ordering information 23.2 8.3 .913 .327 Type No. 16.4 16 X8345 Module for type 8345 .645 .63 Module F remote trip module Assembly version 01 only in pole 1 02 only in pole 2 Remote trip version Internal connection diagram X1 DC Voltage rating 12 12 V 24 24 V 1 1-pole protected line Terminal design hydraulic-magnetically with additional 02 blade terminals DIN 4644-A2.8-0.5 remote trip coil M module mounted to circuit breaker X8345 - F 01 X1 12 02 M ordering example FA 2 Preferred types + - Preferred types remote trip module: X8345-F-01-X1-12-02-M X8345-F-01-X1-24-02-M Technical data Voltage ratings and typical internal resistance values Voltage ratings DC 12 V; DC 24 V Power consumption approx. 40 W Voltage rating Internal resistance (Ω) Pulse operation 20 ms < t < 100 ms/t > 10 sec ON OFF (Continuous duty possible for multipole DC 12 V 3.2 devices upon request) DC 24 V 14.6 Typical life 10,000 operations at U N Ambient temperature -40...+85 °C (-40...+185 °F) Insulation co-ordination (IEC 60664) 2.5 kV/2 (EN 60934) Dielectric strength test voltage between main circuit and trip coil circuit AC 3,000 V (EN 60934) Insulation resistance > 100 MΩ (DC 500 V) Vibration 6 g (57-2000 Hz) ± 0.46 mm (10-57 Hz) shock direction 1/2 4 g (57-2000 Hz) ± 0.30 mm (10-57 Hz) shock direction 3/4 3 g (57-2000 Hz) ± 0.23 mm (10-57 Hz) shock direction 5/6 to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 100 g (11 ms) (not when mounted upside down) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka mm This is a metric design and millimeter dimensions take precedence ( ) Humidity 240 hours at 95 % RH inch to IEC 60068-2-78, test Cab All dimensions without tolerances are for reference only. In the interest of improved design, Mass approx. 8.5 g (without base unit) performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 8 www.e-t-a.de 1801 19.0 .748 7.8 .307 Remote trip module X8345-F for Circuit Breaker 8345-... Remote ON/OFF actuation X8345-R for Circuit Breaker 8345 Description The X8345-R is an additional module which provides remotely controlled ON and OFF functionality for the E-T-A series 8345 magnetic circuit breaker range. The module actuator, which is motor driven, is factory fitted adjacent to the circuit breaker(s) which it is controlling. The module can be operated by a suitable external changeover switch, momentary switches (one ON, one OFF). The status of the actuator will follow the position of the external switch, i.e. if the circuit breaker trips electrically or is operated manually, the actuator will not change. A single module will control a single pole breaker or multipole circuit breakers up to 3 poles. In the application it has to be ensured that the supply voltage is maintained at all times. When switching the circuit breaker OFF manually the module has also to 1 be switched off by means of the changeover switch before switching the X8345-R breaker on again. The same is true for normal switch-on of the breaker. US patent number: US 7,532,095 B2 Internal connection diagrams Ordering information Type number single pole, hydraulic-magnetic protection, X8345 Module for type 8345, 1, 2 pole and 3 pole with remote ON/OFF actuation (operated by changeover switch) Module R remote ON/OFF actuation changeover switch Operating voltage (not part of the product) 24 DC 24 V Add-on version 01 mounted on right side Mounting method OFF C ON -+ X8345-R 00 front panel mounting (standard) 02 2-bracket: module and circuit breaker fitted M Terminal design 111 01 spring loaded screwless terminal 5-pin 8345 with Si Supply status M module mounted to the base unit 2 12 14 X8345 - R 24 01 00 01 M ordering example single pole, hydraulic-magnetic protection, with remote ON/OFF actuation Technical data (actuated by two momentary switches) Voltage rating DC 24 V (16...32 V) momentary switch ON duty 50 % / 60 sec (not part of the product) Trip time < 2 sec Blocking current < 1.5 A OFF C ON -+ X8345-R Control current < 3 mA M Typical life 10,000 operations (ON/OFF) 111 8345 with Si Ambient temperature -25...70 °C (-13...158 °F) Insulation co-ordination (IEC 60664) 2.5 kV/2 (EN 60934) Dielectric strength 2 12 14 pole to module test voltage AC 1,500 V (EN 60934) Insulation resistance > 100 MΩ (DC 500 V) Vibration 10 g (57-2000 Hz), ± 0,76 mm (10-57 Hz) to IEC 60068-2-6, test Fc, Typical applications 10 frequency cycles/axis Remote circuit breaker control (ON/OFF) for communication systems, Shock 100 g (11 ms) to IEC 60068-2-27, test Ea marine installations, automation equipment and similar requirements. Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH, Caution: to IEC 60068-2-78, test Cab During actuation of the remote control, free travel of the toggle must Mass approx. 65 g (without base unit) be ensured. 1801 www.e-t-a.de 9 Remote ON/OFF actuation X8345-R for Circuit Breaker 8345 Dimensions X8345-R-24-01-02-01-M 42 1.65 1 19 57 .748 38 OFF C ON - + 2.24 1.49 M6 spring loaded 76 screwless terminal 62 5-pin 2.99 2.44 2 0,2 – 1,2 mm (AWG 24 – AWG16) 78 3.07 X8345-R-24-01-00-01-M OFF C ON - + 16 14.2 23 12 .629 .905 .472 .559 49.2 1.94 63.5 2.5 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. mm This is a metric design and millimeter dimensions take precedence ( ) Errors and omissions excepted. inch 10 www.e-t-a.de 1801 30° 48 19.7 1.89 .775 11 .433 14 .551 63.5 63.5 2.5 2.5
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the 8345B23AU3M2DB1B2B30A?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Related Products
MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...
MINIATURISED SINGLE POLE THERMAL CIRCUIT BREAKER WITH PUSH-TO-RESET TEASE FREE, TRIP-FREE, SNAP ACTI...
Manufacturers




What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods