Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number 100NHG2B-690
Manufacturer EATON BUSSMANN
Category Circuit Protection »  Fuses
Price Request Quote
Lead Time Request Quote

Description

Fuse NH 100A 690V Holder Screw 75 X 60 X 74mm Carton
100NHG2B-690

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Electronics Finder is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a 100NHG2B-690? We can help you find it at a competitive price!

Specifications

Manufacturer Eaton Bussmann
Manufacturers Part # 100NHG2B-690
Sub-Category Fuses
Packaging Carton
Factory Pack Quantity 3

Datasheet

Download "IEC_British_Standard_Fuses.pdf" (869 KiB)

Extracted Text

IEC & British Fuses IEC & British Standard Fuses IEC and British Standard Fuses Section Contents Application Data Page The standard range of fuses for low voltage industrial and general purpose applications meet the requirements of Application Data ..................... 217-218 BS 88 and IEC 60269. By using advanced fuse technology, CSA Type P and Type D fuses current ratings up to 400A have compact dimensions, but (CDS, CDN & PON) . . . . . . . . . . . . . . . . . . . . . . . . . . . .219 retain standard dimensional and performance requirements. ® Tron HRC Form II Class C fuses These designs are for 315/240V systems. The standard (CGL Form II Class C) . . . . . . . . . . . . . . . . . . . . . . . . . . 220 range of fuses are available from 2-1250A in the following HRCI Industrial ceramic body fuses (CIF21 HRCI-CA & tag forms: Offset Blade - Offset Bolted - Center Bolted. CIF06 HRCI-CB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 Supplementary ranges cover applications up to 660Vac and HRCI-J Fast-acting fuses (CJ HRCI-J) . . . . . . . . . . . . . . . 222 500Vdc including those with nonstandard tag fixings. HRCI-Miscellaneous Type K fuses (CIH, CIK & Cooper Bussmann fuses are manufactured under quality CIL HRCI-MISC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 systems independently assessed to BS 5750 (ISO 9002) and HRC Form II current-limiting fuses . . . . . . . . . . . . . . . . . .224 appropriate ratings carry the ASTA 20 endorsement. BS 88 British Standard low voltage fuses (SSD, NSD, Selecting fuses is relatively simple and effective. The ESD & STD, NITD, AAO, BAO, OSD, CEO, following notes cover the majority of applications. For further DEO BS 88 Part 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 information contact our Application Engineers at BS 88 British Standard low voltage fuses (AC, AD, BC, 636-527-1270. BD, CD, DD, ED, EFS & EF, FF, FG, GF, GG, GH BS 88) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226 Circuit Loading DIN Style Type D (D16, D27, D33, D125 Type D) . . . . . . 227 The current rating of the fuse should not be less than the full Neozed low voltage fuses (NZ01, NZ02 Type D0) . . . . . . 227 load current of the circuit. The circuit should be so designed NH HRC Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228-231 that small overloads of long duration will not be of frequent occurrence. Class gG/gL IEC Industrial ferrule fuses (C08G, C08M, C10G, C10M, C14G, C14M, C22G, C22M) . . . . . . . . . . 232 Cable Ratings & Protection Class aM IEC Industrial ferrule fuses (C08M, C10M, There is an increasing move away from 70°C PVC insulation C14M, C22M) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233 to materials that are more environmentally friendly, for Class aM & gG/gL IEC Industrial ferrule fuses with striker example 90°C XLPE. The ratings of fusegear, switches, (C14G_S, C22G_S, C14M_S, C22M_S) . . . . . . . . . . . . . 234 accessories, etc. are generally based upon the equipment HRC fuse holders being connected to conductors intended to be operated at a CAMaster . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235 temperature not exceeding 70°C in normal service. SAFEloc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235 In view of the above, it is recommended that the practice of designs based upon conductor temperatures of 70°C be regarded as the norm. The equipment manufacturer should be consulted to ascertain the reduction of nominal current RED indicates NEW information rating of the equipment if conductor temperatures exceeding 70°C are used. In addition, an overriding factor is often voltage drop. Fuses with gG characteristics protect associated cables against both overload and short-circuit current, provided that the current rating of the fuse 1N is equal or less than the current carrying capacity of the cable 1z. In motor circuits, the motor starter will provide the overload protection and the fuses will provide the short-circuit protection. The maximum fuse size that can be used depends upon the type of cable used and is determined using the appropriate K factor. The following table gives the maximum sizes of fuses that are recommended for two popular cables with copper conductors, 70°C PVC (K = 115) and 90°C thermosetting (K = 143). For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 217 IEC & British Standard Fuses Application Data for BS Low Voltage Fuses Max. Fuse Rating (amps) Capacitor Circuits 2 Cable Size (mm ) K = 115 K = 143 11616 For power factor correction in capacitor circuits, the fuse 1,5 20 25* should be chosen with a current rating greater than 1.5 times 2.5 32* 32* the rated capacitor current. This takes into account the high 4 50* 50* inrush current, circuit harmonics and capacitor tolerances. 6 63* 63* 10 100* 125* 16 125* 160* Motor Circuits 25 200* 250* In motor circuits, the fuse has to withstand the motor's 35 315* 355* 50 400* 500 starting current and often requires a higher rating than the 70 560 630 motor's full load current. Coordination recommendations are 95 710 800 made by the manufacturers of motor starters in accordance 120 800 1000 * Extended Motor Circuit dual ratings can be used. with IEC 60947-4-1. To get Type 2 coordination with fuses, tests are performed with the latest gG or gM fuses to BS 88 Protection Against Electrical Shock 2 or IEC 60269 that have pre-arcing I t values towards the For a TN System, a disconnecting time not exceeding 5s is bottom of specified limits. This means that Cooper permitted for a distribution circuit. The maximum values of Bussmann fuses are suitable to provide Type 2 coordination. earth fault loop impedance (Zs) of 240V for Cooper Bussmann gG fuses to BS 88: Parts 2 and 6 are: Extended dual ratings of motor circuit protection fuses with gM characteristics are available in most popular fuse sizes to Rating (A) Zs (Ohms) Rating (A) Zs (Ohms) Rating (A) Zs (Ohms) 6 14 50 1.1 250 0.16 extend the use of associated equipment with appropriate 10 7.7 63 0.86 315 0.13 economies. In the majority of applications, gG fuses are 16 4.3 80 0.60 400 0.096 used. It is not essential to use gM fuses for motor circuit 20 3.0 100 0.44 500 0.073 25 2.4 125 0.35 630 0.054 protection, they simply extend the utilization of standard 32 1.9 160 0.27 800 0.044 equipment. 40 1.4 200 0.20 Below is a table of recommended fuses at 415V. In most Ambient Temperature applications, the run-up time is less than 5 seconds and duty The derating, in terms of current, of 0.5% per °C above an is infrequent - no more than twice per hour. The next larger ambient of 35°C is recommended. rating should be used for more demanding applications. Interrupting Rating Direct On-line Asst. Start Standard Motor Circuit Standard The standardized interrupting rating values are 80kA for Rating Motor (gG) (gM) (gG) voltages of 415Vac and above, and 40kA for DC kW A A A A applications. The 240Vac designs have an interrupting rating 0.25 0.8 4 - 2 of 50kA. 0.37 1.1 4 - 2 0.55 1.5 6 - 4 Coordination Ratio 0.75 2.0 6 - 4 1.1 3 0 10 - 6 All fuses to BS 88 Parts 2 and 6 will give a coordination ratio 1.5 3.6 16 - 0 1 2.2 5.0 16 - 0 1 of 2:1; and for most practical situations a ratio of 1.6:1 (two 3.0 6.5 20 - 6 1 steps in the R10 series). Example: an upstream fuse rated at 4.0 8.4 20 - 6 1 160A will coordinate with a downstream fuse rated at 100A. 5.5 11.0 25 20M25 2 20 7.5 15.0 40 32M40 25 Current and Energy Limitation 11.0 20.0 50 32M50 32 15.0 27.0 63 32M63 40 2 The range of fuses have pre-arcing I t values towards the 18.5 33.0 80 63M80 50 bottom limits of BS 88 Parts 2 and 6. This ensures excellent 22.0 38.0 80 63M80 50 30.0 54.0 100 63M100 80 current and energy limitation. They also have lower power 37.0 66.0 125 100M125 80 losses at rated current. This assists in the appropriate 45.0 79.0 160 100M160 100 interchangeability with other makes of fuses. 55.0 98.0 160 100M160 100 75.0 135.0 250 200M250 160 Transformers 90.0 155.0 250 200M250 160 110.0 185.0 315 200M315 200 When fuses are used on the primary side of transformers, 132.0 220.0 355 315M400 250 the normal fuse current rating should be at least twice the 150.0 250.0 355 315M400 315 185.0 310.0 450 400M500 355 nominal transformer primary current. 200.0 335.0 500 4 00M500 400 225.0 375.0 560 - 400 Fluorescent Lighting 250.0 415.0 560 - 450 The normal fuse current rating should be at least twice the 280.0 460.0 630 - 500 335.0 562.0 710 - 630 normal full load current of the maximum number of lights to 355.0 596.0 800 - 710 be simultaneously switched. For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 218 IEC & British Fuses IEC & British Standard Fuses CSA Type P and Type D Fuses CDS, CDN & PON Type P & D Specifications Description: CSA time-delay Type D & P fuses. Dimensions: See Catalog Numbers table and Dimensions illustration. Ratings: Volts: — 250Vac (CDN & PON) — 600Vac (CDS) Amps: — 10-600A IR: — 10kA minimum Agency Information: CE, CSA Certified to C22.2 No. 59.1. Features and Benefits • Economical fuse in a variety of ratings for applications not requiring time-delay. Dimensions Typical Applications • Lighting, heating and other circuits not subject to temporary A B surges and where available short-circuit current are relatively low. Basic Catalog Numbers Ferrule Design—1 through 60A Time-Delay CSA Type “D” Fuses Catalog Amp Numbers Volts Ratings Below 10A use FRN-R 10, 12, 15, 20, 25, 30, A B 35, 40, 45, 50, 60, 70, 80, 90, 100 C D 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, CDN 250Vac 450, 500, 600 F Below 10A use FRS-R 10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60 E 70, 80, 90, 100, 110, 125, 150, 175, 200, CDS 600Vac Knife Blade—70 through 600A 225, 250, 300, 350, 400, 450, 500, 600 One-Time CSA Type “P” Fuses Catalog Amp Number Volts Ratings PON 250Vac 15, 20, 25, 30, 35, 40, 45, 50, 60 Catalog Numbers Dimensions in (mm) Basic Catalog Number Amp A B Max C Min D Min E F and Volts Ratings Overall Diameter Blade Length Barrel Length Blade Thickness Blade Width 1-30 2.0 (50.8) 0.56 (14.3) — — — — 35-60 3.0 (76.2) 0.81 (20.6) — — — — 70-100 5.88 (149.4) — 1.0 (25.4) — 0.13 (3.2) 0.75 (19.1) CDN/PON 250Vac 110-200 7.3 (185.4) — 1.38 (34.9) 4.13 (104.8) 0.19 (4.8) 1.13 (28.6) 225-400 8.63 (219.2) — 1.88 (47.6) 4.63 (117.5) 0.25 (6.4) 1.63 (41.3) 450-600 10.38 (263.7) — 2.25 (57.2) 5.19 (131.8) 0.25 (6.4) 2 (50.8) 1-30 5.0 (127.0) 0.81 (20.6) — — — — 35-60 5.5 (139.7) 1.06 (27.0) — — — — 70-100 7.88 (200.2) — 1.0 (25.4) — 0.13 (3.2) 0.75 (19.1) CDS 600Vac 110-200 9.63 (244.6) — 1.38 (34.9) 6.13 (115.6) 0.19 (4.8) 1.13 (28.6) 225-400 11.63 (295.4) — 1.88 (47.6) 7.13 (118.1) 0.25 (6.4) 1.63 (41.3) 450-600 13.38 (339.9) — 2.25 (57.2) 8.19 (208.0) 0.25 (6.4) 2 (50.8) To Order To order, specify Basic Catalog Number and amp rating. Example: CDN-30 Data Sheet: 4126 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 219 IEC & British Standard Fuses ® Tron HRC Form II Class C Fuses Dimensions CGL Form II Class C Specifications 0.81" 0.22" 0.22" (20.64mm) Description: Current-limiting HRCII-C fuses (5.56mm) (5.56mm) designed to withstand inrush currents on 0.06" typical motor start-ups while offering high 2.0" (1.59mm) (50.8mm) 0.34" 0.94" current limitation in the short-circuit region. 2.80" (8.73mm) (23.81mm) (71.04mm) Dimensions: See Dimensions illustrations. 3.31" (84.14mm) Ratings: CGL 1-30 Volts: — 600Vac/250Vdc (1-30A) 0.81" 0.22" 0.22" (20.64mm) (5.56mm) (5.56mm) Amps: — 1-600A IR: — 200kA (40,000A DC) 0.06" 2.0" (1.59mm) Agency Information: CE, CSA Certified, (50.8mm) 0.50" 2.80" (12.7mm) 1.06" C22.2 No. 106. (71.04mm) (26.92mm) 3.5" (88.9mm) Features and Benefits CGL 35-60 • Close sizing to loads allows using smaller and less costly switches 1.34" 0.343" 0.343" (34.04mm) (8.71mm) (8.71mm) • Provides a higher degree of short-circuit protection • Helps protect motors against burnout from overloads 0.09" 2.39" (2.29mm) (60.72mm) 0.75" Typical Applications 1.375" (19.05mm) 3.64" (34.93mm) (92.47mm) • For use in circuits subject to surge currents such as those 4.31" (109.54mm) caused by motors, transformers and other inductive loads CGL 70-100 Catalog Numbers (-Amps) CGL-1 CGL-40 CGL-175 0.343" 0.343 (8.71mm) CGL-2 CGL-45 CGL-200 (8.71mm) CGL-3 CGL-50 CGL-225 CGL-4 CGL-60 CGL-250 CGL-6 CGL-70 CGL-300 0.125" 3.00" (3.18mm) 0.75" CGL-10 CGL-80 CGL-350 (76.2mm) 1.50" (19.05mm) 4.30" (38.1mm) CGL-15 CGL-90 CGL-400 (109.22mm) 5.31" CGL-20 CGL-100 CGL-450 (134.87mm) CGL-25 CGL-110 CGL-500 CGL 110-200 CGL-30 CGL-125 CGL-600 0.19" (4.76mm) CGL-35 CGL-150 0.38" 1.0" (9.53mm) (25.4mm) 1.0" (25.4mm) 3.0" 2.38" (76.2mm) (60.33mm) 5.25" (133.35mm) 8.19" (207.96mm) CGL 225-400 1.0" 0.41" (25.4mm) (10.32mm) 1.0" (25.4mm) .60" (15.24mm) 3.0" 0.375" (76.2mm) (9.53mm) 5.25" 3.00" (133.35mm) (76.2mm) 8.19" (207.96mm) CGL 450-600 Data Sheet: 4125 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 220 IEC & British Fuses IEC & British Standard Fuses HRCI Industrial Ceramic Body Fuses CIF21 HRCI-CA CIF06 HRCI-CB Specifications Specifications Description: The HRCI-CA fuse provides Description: A miniature industrial fuse that both overload and short-circuit protection to provides both short-circuit and overload HRCI requirements. Offset blades for bolt-on protection and the CIF06 fits the 30A mounting. CIF21 fuse fits the Cooper SAFEloc fuse holder. Bussmann CAMaster fuse holder (see data Dimensions: See Dimensions illustration. sheet 4132). Construction: Ground ceramic body with Dimensions: See Dimensions illustration. plated end caps. Construction: Ceramic body. Ratings: Ratings: Volts: — 600Vac/250Vdc Volts: — 600Vac/250Vdc Amps: — 1-30A Amps: — 1-30A IR: — 200kA RMS Sym. IR: — 200kA RMS Sym. Agency Information: CE, CSA C22.2 No. 106-M92 (3-30A Agency Information: CE, CSA C22.2, No. 106-M92. only). Mounting: Bolt-on. Mounting: Clip-in offset blades. Catalog Numbers Catalog Number Catalog Amp Numbers Ratings Catalog Amp Numbers Ratings 1CIF21 1 1CIF06 1 3CIF21 3 3CIF06 3 6CIF21 6 6CIF06 6 10CIF21 10 10CIF06 10 15CIF21 15 15CIF06 15 20CIF21 20 20CIF06 20 25CIF21 25 25CIF06 25 30CIF21 30 30CIF06 30 Features and Benefits Features and Benefits • Close sizing to loads allows using smaller and less costly • Close sizing to loads allows using smaller and less costly switches switches • Provides a higher degree of short-circuit protection • Provides a higher degree of short-circuit protection • Helps protect motors against burnout from overloads • Helps protect motors against burnout from overloads Typical Applications Typical Applications • For use in circuits subject to surge currents such as those • For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads caused by motors, transformers and other inductive loads Dimensions - in (mm) Dimensions - in (mm) 2.15 (54.5) 2.38 (60.4) 1.44 (35.5) 1.44 (35.5) 0.19 (4.7) 0.5 (12.7) 0.44 (11.1) 0.54 (13.8) 0.54 (13.8) 0.03 (3.5) 1.75 (44.5) 0.03 (0.81) 0.14 (3.5) Data Sheet: 4128 Data Sheet: 4127 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 221 IEC & British Standard Fuses HRCI-J Fast-acting Fuses Dimensions CJ HRCI-J Specifications 1CJ to 60CJ A Description: HRCI-J fast-acting B B fuses are industrial duty fuses with C the excellent current-limiting characteristics of fast-acting HRCI-J fuses to limit damage to equipment 70CJ to 600CJ E A and installations by the thermal and K F magnetic energy associated with a J H large short-circuit fault current. C D Overload characteristics limit cable damage due to low overload currents. B Dimensions: See Catalog Numbers table and Dimensions G illustrations. Construction: Ceramic body fuse. Ratings: Volts: — 600Vac (or less), 250Vdc Amps: — 1-600A IR: — 200kA Agency Information: CSA C22.2 No. 106 M92; Designed to BS 88:2, IEC 60269-2. Catalog Numbers Catalog Numbers Catalog Amp Dimensions in (mm) Numbers RatingsABCDE F G H J K 1CJ 1 3CJ 3 6CJ 6 10CJ 10 15CJ 15 2.25 (57) 0.5 (12.7) 0.81 (20.6)——————— 20CJ 20 25CJ 25 30CJ 30 35CJ 35 40CJ 40 45CJ 45 2.38 (60) 0.63 (16) 1.06 (27)——————— 50CJ 50 60CJ 60 70CJ 70 80CJ 80 4.63 (117) 3.63 (92) 1.13 (28) 0.75 (19) 0.13 (3.2) 1 (25.4) 0.5 (12.7) 0.28 (7.1) 0.38 (9.5) 2.63 (67) 90CJ 90 100CJ 100 110CJ 110 125CJ 125 150CJ 150 5.75 (146) 4.38 (111) 1.63 (41) 1.13 (28.6) 0.19 (4.8) 1.38 (35) 0.69 (17.5) 0.28 (7.1) 0.38 (9.5) 3 (76) 175CJ 175 200CJ 200 225CJ 225 250CJ 250 300CJ 300 7.13 (181) 5.25 (133) 2.13 (54) 1.63 (41) 0.25 (6.3) 1.88 (47.6) 0.94 (24) 0.41 (10.3) 0.53 (13.5) 3.38 (86) 350CJ 350 400CJ 400 450CJ 450 500CJ 500 8 (203) 6 (152) 2.63 (66) 2 (51) 0.38 (9.5) 2.13 (54) 1 (25.4) 0.53 (13.5) 0.69 (17.5) 3.75 (96) 600CJ 600 Data Sheet: 4129 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 222 IEC & British Fuses IEC & British Standard Fuses HRCI - Miscellaneous Type K Fuses CIH, CIK & CIL HRCI-MISC Specifications Description: HRI fuses provide both overload and short-circuit protection, featuring offset blades for bolt down mounting. Dimensions: See Catalog Numbers table and Dimensions illustration. Construction: Ceramic body. Ratings: Volts: — 600V Amps: — 1-100A IR: — 200kA@600V Agency Information: CE, CSA C22.2 No. 106 M92. Dimensions F J E A D G K B G L H C (The CIL14 has a rejection hole, not a slot as shown above.) Catalog Numbers Dimensions: in (mm) Catalog Amp Numbers Ratings A Max B Max C Max D Nom E Nom F Nom G Nom H Nom J Max K Nom L Max 1CIH07 1 2.25 (57) 0.94 (24) 3.38 (86) 0.38 (9.2) 0.04 (1.0) 2.88 (73) 0.21 (5.2) 0.31 (8) 1 (25.4) 0.10 (2.6) 2.38 (60) 3CIH07 3 6CIH07 6 10CIH07 10 2.25 (57) 0.94 (24) 3.38 (86) 0.38 (9.2) 0.04 (1.0) 2.88 (73) 0.21 (5.2) 0.31 (8) 1 (25.4) 0.10 (2.6) 2.38 (60) 15CIH07 15 20CIH07 20 25CIH07 25 30CIH07 30 35CIK07 35 2.28 (58) 1.06 (27) 3.56 (91) 0.5 (12.7) 0.05 (1.2) 2.88 (73) 0.21 (5.2) 0.41 (10.5) 1.09 (28) 0.13 (3.2) 2.38 (61) 40CIK07 40 2.28 (58) 1.06 (27) 3.56 (91) 0.5 (12.7) 0.05 (1.2) 2.88 (73) 0.21 (5.2) 0.41 (10.5) 1.09 (28) 0.13 (3.2) 2.38 (61) 50CIK07 50 60CIK07 60 80CIL14 80 2.75 (70) 1.44 (37) 4.38 (111) 0.75 (19) 0.09 (2.5) 3.69 (94) 0.34 (8.7) 0.41 (10.5) 1.5 (38.5) — 2.91 (74) 1.44 (37) 4.38 (111) 0.34 (8.7) 1.5 (38.5) 2.75 (70) 0.75 (19) 0.09 (2.5) 3.69 (94) 0.41 (10.5) — 2.91 (74) 90CIL14 90 100CIL14 100 Recommended Fuse Holders Fuse Fuse Holder 1-30A CM30CF 35-60A CM60CF Data Sheet: 4130 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 223 IEC & British Standard Fuses HRC Form II Current-limiting Fuses Dimensions HRC Form II F J E G A Specifications D H07C Description: HRC Form II B (Offset Blades) current-limiting fuses. H C Dimensions: See Catalog Numbers table and Dimensions F J illustrations. E A G K07C/K07CR/ D Construction: Ceramic body. L14C/M14C B Ratings: (Offset Blades) H Volts: — 600Vac (or less) C — 250Vdc C B Amps: — 2-600A A H IR: — 200kA RMS Sym. G D L09C/M09C/P09C Agency Information: CE, CSA C22.2 No.106M1992; (Center Blades) BS 88:2, IEC 60269:2. E F Typical Applications • Used to protect motor control circuits, together with K F K B contactors and overload protection relays to provide Type 2 A coordination - per IEC 60947-4. G P11C/R11C D (Center Blades) H E C Catalog Numbers Dimensions in (mm) Catalog Amp Numbers Ratings A B C D E F G H J K CSA Category 2H07C 2 1.38 (35) 0.56 (14) 3.38 (85) 0.38 (9) 0.06 (1.2) 2.88 (73) 0.22 (5.6) 0.31 (8) 0.56 (14) — HRCII-C 4H07C 4 6H07C 6 10H07C 10 1.38 (35) 0.56 (14) 0.38 (9) 3.38 (85) 0.56 (14) — 15H07C 15 HRCII-C 20H07C 20 0.06 (1.2) 2.88 (73) 0.22 (5.6) 0.31 (8) 25H07C 25 30H07C 30 40K07C 40 2.19 (56) 0.88 (22) 3.44 (87) 0.5 (13) 0.06 (1.2) 2.88 (73) 0.22 (5.6) 0.31 (8) 0.88 (22) — HRCII-C 3.44 (87) — 50K07C 50 2.19 (56) 0.88 (22) 0.5 (13) 0.88 (22) 60K07C 60 80K07CR 80 2.19 (56) 0.88 (22) 3.75 (95) 0.5 (13) 0.06 (1.2) 2.88 (73) 0.22 (5.6) 0.31 (8) 0.88 (22) — HRCII-MISC 3.75 (95) — HRCII-MISC 100K07CR 100 80L14C 80 2.38 (60) 0.88 (21.4) 4.38 (111) 0.56 (14.3) 0.13 (3.2) 3.69 (94) 0.34 (8.7) 0.44 (11) 1 (25.4) — HRCII-C 0.56 (14.3) HRCII-C 2.38 (60) 0.88 (21.4) 0.13 (3.2) 1 (25.4) — 100L14C 100 4.38 (111) 3.69 (94) 125M14C 125 2.56 (65) 1.5 (38) 4.38 (111) 0.75 (19) 0.09 (2.4) 3.69 (94) 0.34 (8.7) 0.44 (11) — — HRCII-MISC 2.56 (65) 1.5 (38) 0.75 (19) 0.09 (2.4) 0.44 (11) — — 150M14C 150 HRCII-MISC 200M14C 200 80L09C 80 2.38 (60) 0.88 (21.4) 5 (127) 0.56 (14) 0.13 (3.2) 4.38 (111) 0.34 (8.7) 0.44 (11) — — HRCII-MISC 2.38 (60) 0.88 (21.4) 5 (127) 0.56 (14) — — 100L09C 100 0.34 (8.7) 0.13 (3.2) 125M09C 125 2.56 (65) 1.5 (38) 5.38 (136) 0.75 (19) 0.13 (3.2) 4.38 (111) 0.34 (8.7) 0.56 (14) — — HRCII-C 2.56 (65) 1.5 (38) 0.75 (19) 0.56 (14) — — HRCII-C 150M09C 150 4.38 (111) 200M09C 200 5.38 (136) 250P09C 250 3.06 (178) 2.31 (59) 5.38 (136) 1 (25.4) 0.19 (4.8) 4.38 (111) 0.34 (8.7) 0.5 (13) — — HRCII-MISC 300P09C 300 0.5 (13) 0.19 (4.8) — — HRCII-MISC 350P09C 350 400P09C 400 3.06 (178) 2.31 (59) 250P11C 250 3.06 (178) 2.31 (59) 8.25 (210) 1 (25.4) 0.19 (5) 5.25 (133) 0.41 (10) 0.63 (16) — 1 (25) HRCII-C 1 (25.4) 300P11C 300 0.19 (5) — 1 (25) 350P11C 350 8.25 (210) 5.25 (133) 0.41 (10) 0.63 (16) HRCII-C 400P11C 400 450R11C 450 3.19 (81) 2.88 (73) 8.25 (210) 1 (25.4) 0.25 (6.3) 5.25 (133) 0.41 (10) 0.63 (16) — 1 (25) HRCII-C 3.19 (81) 2.88 (73) 0.25 (6.3) — 1 (25) 500R11C 500 600R11C 600 Data Sheet: 4131 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 224 IEC & British Fuses IEC & British Standard Fuses BS 88 British Standard Low Voltage Fuses SSD, NSD, ESD BS 88 Part 1 STD, NITD, AAO, BAO, OSD, CEO, DEO BS 88 Part 1 Specifications Description: The NSD and ESD are low voltage Specifications fuses complying with general purpose gG Description: The STD to DEO types are low characteristics. voltage fuses complying with general purpose gG Construction: Ceramic body. characteristics. Ratings: Construction: Ceramic body. Volts: — 240-550Vac (See Catalog Numbers table) Ratings: Amps: — 2-63A (See Catalog Numbers table) Volts: — 240-550Vac (See Catalog Numbers — 20M25-63M100A Motor Starter ratings table) (See Catalog Numbers table) Amps: — 2-200A (See Catalog Numbers table) IR: — 33kA (SSD) — 20M25-200M315A Motor Starter ratings — 80kA (NSD, ESD) (See Catalog Numbers table) Agency Information: CE, Meets the requirements of IR: — 33kA (STD) BS 88 Part 1 and IEC 60269-1. — 80kA (NITD, AAO, BAO, CEO, DEO) Mounting: Offset blades. Agency Information: CE, Meets the requirements of BS 88 Part 1 and IEC 60269-1. Basic Catalog Numbers Mounting: Offset bolted blades. Basic Max AC Catalog Amp Voltage BS 88 Typical Applications Numbers Ratings Ratings Ref. • The STD type are used in 240V street lighting cut-outs. SSD 2, 4, 6, 10, 16, 20, 25, 32 240 E1 NSD 2, 4, 6, 10, 16, 20, 25, 32, 550 F1 • NITD to DEO types used for industrial and general purpose 20M25*, 20M32*, 20M36*, 32M36*, 32M40*, 415 F1 applications 32M50*, 32M63* 415 F1 Basic Catalog Numbers ESD 2, 4, 6, 10, 16, 25, 32 550 F2 40, 50, 63, 63M80, 63M100* 415 F2 Basic Max AC *“M” indicates motor starter ratings. Catalog Amp Voltage BS 88 Numbers Ratings Ratings Ref. To Order STD 2, 4, 6, 10, 16, 20, 25, 32 240 — NITD 2, 4, 6, 10, 16, 20, 25, 32 550 — To order, specify Basic Catalog Number and amp rating. Example: SSD-20 20M25*, 20M32*, 32M40*, 32M50*, 32M63* 415 — AAO 2, 4, 6, 10, 16, 20, 25, 32, 32M40*, 32M50*, 32M63* 550 — BAO 40, 50, 63, 63M80*, 63M100* 550 A3 Recommended Fuse Holders CEO 32, 40, 50, 63, 80, 100 550 A4 Basic Fuse Holder Catalog 100M125*, 100M160*, 100M200* 415 A4 Catalog Numbers Numbers DEO 125, 160, 200, 200M250*, 200M315* 415 — NSD 32NNSF OSD 80, 100 550 — ESD 63ENSF 100M125*, 100M160* 415 — *“M” indicates motor starter ratings. To Order To order, specify Basic Catalog Number and amp rating. Example: BAO-16 Recommended Fuse Blocks & Holders Basic Fuse Block/Holder Catalog Numbers Catalog Numbers NITD CM32FC AAO CM32F BAO CM63F OSD CM100F CEO BH-0111 Data Sheets 4123 (STD), 4106 (NITD), 4109 (AAO), 4112 Data Sheets 4105 (SSD), 4100 (NSD) and 4101 (ESD) (BAO), 4107 (OSD), 4115 (CEO) and 4117 (DEO) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 225 IEC & British Standard Fuses BS 88 British Standard Low Voltage Fuses AC, AD, BC, BD, CD, DD, ED, EFS BS 88 EF, FF, FG, GF, GG, GH BS 88 Specifications Description: Low voltage fuses that Specifications comply with general purpose gG Description: Low voltage fuses characteristics and available up to 400A complying with general purpose gG with two hole mount and up to 1250A characteristics and available up to with four hole mount. 400A with two hole mount and up Construction: Ceramic body. to 1250A with four hole mount. Ratings: Construction: Ceramic body. Volts: — 415/550Vac, 250Vdc (See Ratings: Catalog Numbers table) Volts: — 415/550Vac, 250/400Vdc Amps: — 2-400A (See Catalog Numbers table) (See Catalog Numbers table for details) — 63M80-400M500A Motor Starter ratings (See Amps: — 355-1250 Catalog Numbers table) IR: — See Catalog Numbers table IR: — See Catalog Numbers table Agency Information: CE, Meets the requirements of Agency Information: CE, Meets the requirements of BS 88 Parts 1 and 2 and IEC269-1. BS 88 Parts 1 and 2 and IEC 60269-1. Mounting: Center bolted blades, four-hole mount. Mounting: Center bolted blades, two-hole mount. Basic Catalog Numbers Basic Catalog Numbers Basic Interrupting Max Voltage Catalog Amp Ratings Ratings BS 88 Basic Interrupting Max Voltage Numbers Ratings AC DC AC DC Ref. Catalog Amp Ratings Ratings BS 88 EF 355, 400 80kA — 415 — C1 Numbers Ratings AC DC AC DC Ref. 400M500* 80kA — 550 — — AC 2, 4, 6, 10, 16, 20, 25, 32 80kA 40kA 550 250 — FF 450, 500, 560, 630 80kA 40kA 550 400 C2 AD 2, 4, 6, 10, 16, 20, 25, 32 80kA 40kA 550 250 — FG 450, 500, 560, 630 80kA 40kA 550 400 — BC 40, 50, 63 80kA 40kA 550 250 — GF 710, 800 80kA 40kA 550 250 C3 63M80*, 63M100* 80kA — 550 — — GG 710, 800 80kA 40kA 550 250 — BD 40, 50, 63 80kA 40kA 550 250 — 1000, 1250 80kA — 550 — — CD 80, 100, 100M125*, 100M160*, 80kA — 415 — B1 GH 710, 800, 1000, 1250 80kA — 550 — — 100M200*, 100M200* *“M” indicates motor starter ratings.*“M” indicates motor starter ratings. DD 125, 160, 200, 80kA — 415 — B2 200M250*, 200M315* ED 250, 315, 355, 400, 315M400* 80kA — 415 — B3 To Order 400M500* 80kA — 550 — B4 EFS 125, 160, 200, 250, 315 80kA 415 — — To order, specify Basic Catalog Number and amp rating. Example: FG-450 *“M” indicates motor starter ratings. To Order To order, specify Basic Catalog Number and amp rating. Example: BC-40 Recommended Fuse Blocks & Holder Basic Fuse Block/Holder Catalog Numbers Catalog Numbers AC BH-0111 Modular fuse block AD 200DF Fuse holder BC BH-0111 Modular fuse block BD 200DF Fuse holder CD 200DF Fuse holder DD 200DF Fuse holder ED BH-1131 Modular fuse block Data Sheets 4110 (AC), 4111 (AD), 4113 (BC), 4114 (BD), Data Sheets 4120 (EF), 4102 (FF), 4122 (FG), 4103 (GF), 4104 4116 (CD), 4118 (DD), 4119 (ED) and 4121 (EFS) (GG) and 4108 (GH) For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 226 IEC & British Fuses IEC & British Standard Fuses DIN Style Type D and Neozed Low Voltage Fuses D16, D27, D33, D125 Type D NZ01, NZ02 Type D0 Specifications Specifications Description: DIN style Type D Description: Low voltage Neozed fuses low voltage fuses. suitable for use on 250Vdc systems. Dimensions: See Catalog Dimensions: See Catalog Numbers table and Numbers table and Dimensions Dimensions illustration. illustrations. Construction: Ceramic body. Construction: Ceramic body. Ratings: Ratings: Volts: — 400Vac Volts: — 500Vac Amps: — 2-63A Amps: — 2-100A IR: — 100kA IR: — 100kA Agency Information: CE Catalog Numbers Agency Information: CE, “D” type fuses complying with DIN 49360 Part 2 and DIN 49515, operating class gL. Catalog Amp Dimension Color Numbers Ratings “D” (mm) Code Catalog Numbers 2NZ01 2 11 Pink Catalog Amp Dimension Color Figure 4NZ01 4 11 Brown Numbers Ratings “D” (mm) Code Number 6NZ01 6 11 Green 2D16 2 6 Pink 10NZ01 10 11 Red 4D16 4 6 Brown 16NZ01 16 11 Grey 6D16 6 6 Green 20NZ02 20 15 Blue 10D16 10 8 Red 1 25NZ02 25 15 Yellow 16D16 16 10 Grey 35NZ02 35 15 Black 20D16 20 12 Blue 50NZ02 50 15 White 25D16 25 14 Yellow 2D27 2 6 Pink 63NZ02 63 15 Copper 4D27 4 6 Brown 6D27 6 6 Green Dimensions (mm) 10D27 10 8 Red 2 16D27 16 10 Grey 20D27 20 12 Blue D 25D27 25 14 Yellow 35D33 35 16 Black 50D33 50 18 White 3 63D33 63 20 Copper 80D125 80 5 Silver 4 36 100D125 100 7 Red Additional Fuselinks: Quick acting fuselinks in body sized D16, D27, D33 and D125 rated 2-100A. Reference number suffixed Q, i.e. 10D27Q. Voltage rating 500V. Gauge rings and keys can also be supplied. Dimensions (mm) Figure 1 Figure 2 Figure 3 Figure 4 Data Sheet: 4124 Data Sheet: 4124 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 227 IEC & British Standard Fuses NH HRC Fuses Ratings: ___NHG___B Volts: — 500Vac/250Vdc Specifications — 690Vac/250Vdc Class: gG/ L g Amps: — 2-1250A Description: DIN IR: — 120kA square bodied, dual Frequency: — 50Hz indication industrial Operating Frequency: — 45-62Hz fuses. Agency Information: IEC 60269, VDE0636, DIN 43620 Construction: Steatite Part 1 to 4, VDE Mark and CE. insulator, corrosion- proof (aluminum) metal Fuse Blocks Size parts with full-contact, SB00-D 000-00 silver-plated copper SB1-D 1*, 1 blades. SB2-D 02, 2, 03, 3 Sizes: DIN 000 to 4. Selectivity Ratio: 1:1.6 up to 500Vac. Dimensions (mm) 2 1 2 1 2 3 4 Fuse a bc c De e e e f 1 3 4 Size a (max) a a (nom) (± 8) (nom) (nom) (max) (max) (max) (nom) (max) 000 78.5 ± 1.5 54 45 ± 1.5 49 ± 1.5 15 35 10 2 ± 0.5 41 21 16 6 8 00 78.5 ± 1.5 54 45 ± 1.5 49 ± 1.5 15 35 11 7.0 ± 0.5 48 30 25 6 15 0 125 ± 2.5 68 62 +3/-1.5 68 +1.5/-3 15 35 11 2.5 ± 0.5 48 30 25 6 15 01 135 ± 2.5 75 62 ± 2.5 68 ± 2.5 15 40 11 2.5 ± 0.5 48 30 25 6 15 1 135 ± 2.5 75 62 ± 2.5 68 ± 2.5 20 40 11 2.5 ± 0.5 53 52 25 6 15 02 150 ± 2.5 75 62 ± 2.5 68 ± 2.5 20 48 11 2.5 ± 0.5 53 52 25 6 15 2 150 ± 2.5 75 62 ± 2.5 68 ± 2.5 25 48 11 2.5 ± 0.5 61 60 25 6 15 03 150 ± 3 75 62 ± 2.5 68 ± 2.5 25 60 11 2.5 ± 0.5 61 60 25 6 15 3 150 ± 3 75 62 ± 2.5 68 ± 2.5 32 60 11 3.0 ± 0.5 75 70 25 6 18 4 200 84 80 90 50 85 11 3 120 87 — 8 30 Data Sheet 4173 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 228 IEC & British Fuses IEC & British Standard Fuses NH HRC Fuses Rated gG/gL Dual Indicator Current Voltage Conducting Carton 500Vac / 250Vdc Size (Amps) Metal Gripping Lugs Quantity 2 2NHG000B 3 4 4NHG000B 3 6 6NHG000B 3 10 10NHG000B 3 16 16NHG000B 3 20 20NHG000B 3 25 25NHG000B 3 000 32 32NHG000B 3 35 35NHG000B 3 40 40NHG000B 3 50 50NHG000B 3 63 63NHG000B 3 80 80NHG000B 3 100 100NHG000B 3 00 125 125NHG00B 3 160 160NHG00B 3 10 10NHG0B 3 16 16NHG0B 3 20 20NHG0B 3 25 25NHG0B 3 32 32NHG0B 3 35 35NHG0B 3 0 40 40NHG0B 3 50 50NHG0B 3 63 63NHG0B 3 80 80NHG0B 3 100 100NHG0B 3 125 125NHG0B 3 160 160NHG0B 3 10 10NHG01B 3 16 16NHG01B 3 20 20NHG01B 3 25 25NHG01B 3 32 32NHG01B 3 35 35NHG01B 3 01 40 40NHG01B 3 50 50NHG01B 3 63 63NHG01B 3 80 80NHG01B 3 100 100NHG01B 3 125 125NHG01B 3 160 160NHG01B 3 200 200NHG1B 3 1 224 224NHG1B 3 250 250NHG1B 3 35 35NHG02B 3 40 40NHG02B 3 50 50NHG02B 3 63 63NHG02B 3 80 80NHG02B 3 02 100 100NHG02B 3 125 125NHG02B 3 160 160NHG02B 3 200 200NHG02B 3 224 224NHG02B 3 250 250NHG02B 3 315 315NHG2B 3 2 355 355NHG2B 3 400 400NHG2B 3 250 250NHG03B 3 315 315NHG03B 3 03 355 355NHG03B 3 400 400NHG03B 3 3 500 500NHG3B 3 630 630NHG3B 3 500 500NHG4G 1 4 630 630NHG4G 1 Single Indicator 800 800NHG4G 1 Slotted End 1000 1000NHG4G 1 Tags 1250 1250NHG4G 1 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 229 IEC & British Standard Fuses NH HRC Fuses Rated gG/gL Dual Indicator Current Voltage Conducting Carton 690Vac / 250Vdc Size (Amps) Metal Gripping Lugs Quantity 2 2NHG000B-690 3 4 4NHG000B-690 3 6 6NHG000B-690 3 10 10NHG000B-690 3 000 16 16NHG000B-690 3 20 20NHG000B-690 3 25 25NHG000B-690 3 32 32NHG000B-690 3 35 35NHG000B-690 3 40 40NHG000B-690 3 50 50NHG00B-690 3 00 63 63NHG00B-690 3 80 80NHG00B-690 3 100 100NHG00B-690 3 6 6NHG0B-690 3 10 10NHG0B-690 3 16 16NHG0B-690 3 20 20NHG0B-690 3 25 25NHG0B-690 3 0 32 32NHG0B-690 3 35 35NHG0B-690 3 40 40NHG0B-690 3 50 50NHG0B-690 3 63 63NHG0B-690 3 80 80NHG0B-690 3 100 100NHG0B-690 3 50 50NHG1B-690 3 63 63NHG1B-690 3 80 80NHG1B-690 3 1 100 100NHG1B-690 3 125 125NHG1B-690 3 160 160NHG1B-690 3 200 200NHG1B-690 3 63 63NHG2B-690 3 80 80NHG2B-690 3 100 100NHG2B-690 3 125 125NHG2B-690 3 2 160 160NHG2B-690 3 200 200NHG2B-690 3 224 224NHG2B-690 3 250 250NHG2B-690 3 315 315NHG2B-690 3 250 250NHG3B-690 3 315 315NHG3B-690 3 3 355 355NHG3B-690 3 400 400NHG3B-690 3 425 425NHG3B-690 3 500 500NHG3B-690 3 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 230 IEC & British Fuses IEC & British Standard Fuses NH Fuse Bases SB*-D, SB*-S Part Numbers Up to 690V / 160 - 1250A Part Numbers Current Carton Compatible Size Poles Sizes 00, 0, 1, 2, 3, 4 (Amps) Quantity Fuse Size DIN Screw SB00-D 1 3 00 160A TB00-D 000 & 00 3 1 TB00-D-IP20 Description: NH fuse bases with thermoplastic bodies. DIN rail and screw mounting (size 4 screw 1 SB0-D 3 0 160A 0 3 TB0-D 1 fix). Range of protection accesories for live parts in order to obtain IP20 protection standard. 1 SB1-D 3 1 250A 01 & 1 3 TB1-D 1 1 SB2-D 3 Ratings: 2 400A 02 & 2 3 TB2-D 1 • Voltage: up to 690Vac 1 SB3-D 3 3 630A 03 & 3 3 TB3-D 1 • Amps: 2 to 1250A SB4-S (Screw 4 1 1250A 3 4 Connection only) Applications: Protection of industrial circuits and electrical apparatus Neutral Standards and Approvals: IEC 60269, DIN 43620 Current Carton Size Part Ref (Amps) Quantity NH00 160 SL00 NH0 160 SL0 NH1 250 SL1 3 NH2 400 SL2 NH3 630 SL3 NH4 1000 SL4 Fuse extraction handle Carton Size Part Ref Quantity C00-3 FEH 1 Protection accessories Separation Partition Fuse Casing Terminal Cover Separator 4 5 1 3 Current Size (Amps) Part Carton Part Carton Part Carton Part Carton Ref Quantity Ref Quantity Ref Quantity Ref Quantity NH00* 160A SP00* 2 FC00* 3 CS00* 6 BC00* 2 NH0 160A SP0 2 FC0 3 CS0 6 BC0 2 NH1 250A SP1-2 2 FC1-2 3 CS1 6 BC1-2 2 NH2 400A SP1-2 2 FC1-2 3 CS2 6 BC1-2 2 NH3 630A SP3 2 FC3 3 CS3 6 BC3 2 * For single pole only IP Protection Kits Microswitch Part Reference Description Part Ref Carton Quantity TB00-D-IP20 Complete triple pole fuse base IP20 rated BVL-50 1 FPK0-3P IP20 kit for TB0-D fuse base Microswitch suitable for the following NH Fuse links: FPK1-3P IP20 kit for TB1-D fuse base - 400 Volts gG/gL FPK2-3P IP20 kit for TB2-D fuse base - 500 Volts gG/gL and aM - 690 Volts gG/gL and aM FPK3-3P IP20 kit for TB3-D fuse base For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 231 IEC & British Standard Fuses Class gG/gL IEC 60269 Industrial Ferrule Fuses 8 x 31mm: 400Vac, 0.5 - 25A 10 x 38mm: 500Vac, 0.5 - 32A 14 x 51mm: 400Vac - 500Vac - 690Vac, 1 - 50A 22 x 58mm: 400Vac - 500Vac - 690Vac, 2 - 125A For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 232 IEC & British Fuses IEC & British Standard Fuses Class aM IEC Industrial Ferrule Fuses - Class aM IEC 60269 8 x 31mm: 400Vac, 1 - 8A 10 x 38mm: 400Vac - 550Vac, 0.16 - 25A 14 x 51mm: 690Vac - 500Vac, 0.25 - 50A 22 x 58mm: 400Vac - 500Vac - 690Vac, 2 - 125A Neutral Links For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 233 IEC & British Standard Fuses Class aM & gG/gL IEC Industrial Ferrule Fuses with Striker Class gG/gL with Striker Catalog Number Amp Watts Loss Voltage Interrupting With Striker Rating (W) (AC) Rating (kA) 14 X 51 C14G2S 2 0.24 500 120 C14G4S 4 0.45 C14G6S 6 0.42 C14G8S 8 0.70 C14G10S 10 0.53 C14G12S 12 0.88 500 120 C14G16S 16 1.16 C14G20S 20 1.23 C14G25S 25 1.46 C14G32S 32 2.04 C14G40S 40 3.34 C14G50S 50 3.04 400 Catalog Number Amp Watts Loss Voltage Interrupting With Striker Rating (W) (AC) Rating (kA) 22 X 58 C22G4S 4 0.48 690 80 C22G6S 6 0.47 C22G8S 8 0.73 C22G10S 10 0.74 C22G12S 12 0.83 C22G16S 16 1.21 690 80 C22G20S 20 1.29 C22G25S 25 1.53 C22G32S 32 2.13 C22G40S 40 3.40 C22G50S 50 3.48 C22G63S 63 4.46 C22G80S 80 5.86 500 120 500 C22G100S 100 6.61 120 C22G125S 125 8.42 400 Class aM with Striker Catalog Number Amp Watts Loss Voltage Interrupting With Striker Rating (W) (AC) Rating (kA) 14 X 51 C14M1S 1 0.14 500 120 C14M2S 2 0.24 C14M4S 4 0.45 C14M6S 6 0.42 C14M8S 8 0.70 C14M10S 10 0.53 500 120 C14M12S 12 0.88 C14M16S 16 1.16 C14M20S 20 1.23 C14M25S 25 1.46 C14M32S 32 2.04 C14M40S 40 3.34 C14M50S 50 3.04 400 Catalog Number Amp Watts Loss Voltage Interrupting 22 X 58 With Striker Rating (W) (AC) Rating (kA) C22M2S 2 0.29 690 80 C22M4S 4 0.48 C22M6S 6 0.47 C22M8S 8 0.73 C22M10S 10 0.74 C22M12S 12 0.83 690 C22M16S 16 1.21 80 C22M20S 20 1.29 C22M25S 25 1.53 C22M32S 32 2.13 C22M40S 40 3.40 C22M50S 50 3.48 C22M63S 63 4.46 500 C22M80S 80 5.86 500 120 C22M100S 100 6.61 120 C22M125S 125 8.42 400 For detailed information, visit the Electrical IEC section at www.cooperbussmann.com 234 IEC & British Fuses IEC & British Standard Fuses HRC Fuse Holders CAMaster SAFEloc Specifications Specifications Catalog Symbol: Catalog Symbol: See table below. See table below. Description: The CAMaster HRC fuse holder Description: The features a unique SAFEloc HRC cam-action for easy fuse fuse holders (for removal while allowing use with HRCI-CB significantly improved fuses) provides a contact pressure between positive, stress- fuse carrier and base free fuse fitting contact that enhances and locks it in position to ensure safe insertion and electrical performance. A range of lockable safety carriers for withdrawal from the base. Base contacts are fully shrouded the fuse holder (catalog reference: LSC), are available. to help protect against electric shock. Shrouds utilize simple slide/snap action allowing access to the contact Ratings: terminal screws. Volts: — 690V Ratings: Amps: — 30-100A (See Catalog Number table for details) Volts: — 600V Agency Information: CE, CSA C22.2 No. 39; IEC 269 Amps: — 30-60A (See Catalog Number table for details) AND BS 88. Agency Information: CE, Designed to accommodate the Mounting: 35mm DIN-rail or single screw mounting. compact range of offset blade fuse to CSA C22.2 No. 106, Catalog Numbers HRCI-CB. Catalog Amp Fuse Mounting: 35mm DIN rail or single screw mounting. Numbers Ratings Details For: Accepted CM20CF 30 HRCI-CA Applications _CIF21 Catalog Numbers* CM30CF 30 _H07C Catalog Amp Fuse CM60CF 60 HRCII Applications _K07C Numbers Ratings Connection Accepted CM100CF 100 _K07CR C30F Front _CIF06 C30BS 30 Back Accessory Catalog Numbers for CAMaster Units C30FBS Front-Back Catalog Amp Fuse Holder C60F Front EK-Amp Numbers Ratings Details Accepted C60BS 60 Back 20BS 30 CM20CF C60FBS Front-Back 32BS 30 Back Stud CM30CF *For use with HRCI-CB Fuses. 60/100BS 60/100 CM60/100CF GLP All Ganging Link Kit 3-Pole NI All 660V Neon Indicator — 20LSC 30 CM20CF 30LSC 30 Security Carrier with Clip CM30CF 60/100LSC 60/100A CM60/100CF Data Sheet: 4133 Data Sheet: 4132 For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa 235 236

Related Products

EATON BUSSMANN
Fuse Neozed Fast Acting 100A 500V Holder Pin 100D125Q
EATON BUSSMANN
Fuse 100A 690V Bolt 46 X 37 X 19mm Carton 100FEE
EATON BUSSMANN
Fuse NH 100A 690V Holder Flat 49 X 30 X 48mm 100NH00G-690
EATON BUSSMANN
1245 40A FA BRICK FUSE 1000 IN REEL ROH
EATON BUSSMANN
Fuse Neozed Fast Acting 10A 500V Holder Pin 50 X 13.2mm 10D16
EATON BUSSMANN
Fuse Neozed Fast Acting 10A 400V Holder Pin 36 X 11mm 10NZ01

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Electronics Finder are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Electronics Finder is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.069 seconds.