EATON BUSSMANN JCH-2R
Specifications
Manufacturer
Eaton Bussmann
Manufacturers Part #
JCH-2R
Industry Aliases
JCH-2R
Sub-Category
Fuses
Selling Alternatives
JCH-2RPK10
Factory Pack Quantity
1
Datasheet
Extracted Text
® Bussmann R-Rated Fuses JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, For Motor Circuit Protection Medium Voltage JCG, JCR-A, & JCR-B • R-Rated medium voltage fuses are back-up current limiting fuses used in conjunction with medium voltage motors and motor controllers. • The JCK-A, JCL-A, & JCR-A are supplied with Cutler- Hammer Ampgard Hookeye. • This single hookeye is on one end of the fuse and aids in the insertion and removal of the fuse. • Current limiting fuses may be designated as R-Rated if they meet the following requirements: 1. The fuse will safely interrupt all currents between its minimum and maximum interrupting ratings. 2. The fuse will melt in a range of 15 to 35 seconds at a value of 100 times the “R’ number (ANSI C37.46). • Bussmann R-Rated current limiting fuses are designed for use with medium voltage starters to provide short-circuit protection for the motor and motor controller. • These fuses offer a high level of fault current interruption in a self-contained, non-venting package which can be mounted indoors or in an enclosure. • Open fuse indication on all fuses. Catalog Symbol: JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B R-Rated Medium Voltage Current Limiting 2400V AC — JCK, JCK-A, JCK-B, JCH 4800V AC — JCL, JCL-A, JCL-B, JCG 7200V AC — JCR-A, JCR-B Max. Design Voltage 2540V AC — JCK, JCK-A, JCK-B, JCH 5080V AC — JCL, JCL-A JCL-B, JCG 8300V AC — JCR-A, JCR-B UL Recognized: 2540V AC — JCK, JCK-A 5080V AC — JCL, JCL-A (2R-24R) UL Recognized (GUIDE #MSSS2, FILE # E96676) Form No. JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B Page 1 of 8 Data Sheet: 6001 2-26-03 SB03044 ® Bussmann R-Rated Fuses JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, For Motor Circuit Protection Medium Voltage JCG, JCR-A, & JCR-B Specifications Buss Maximum Dimensions (Inches) Max. Int. Cap. Min. Int. Cap. Catalog No. Amperage Design Voltage A B C Construction Amps (Asym.) Amps (Sym.) Amps (Sym.) 2400V; R-Rated; Indoor/Enclosure (See Figure 1) JCK-2R 70 2R 2540V 11.24 3.0 3.0 Single 80,000 50,000 165 JCK-3R 100 3R 2540V 11.24 3.0 3.0 Single 80,000 50,000 220 JCK-4R 130 4R 2540V 11.24 3.0 3.0 Single 80,000 50,000 320 JCK-5R 150 5R 2540V 11.24 3.0 3.0 Single 80,000 50,000 410 JCK-6R 170 6R 2540V 11.24 3.0 3.0 Single 80,000 50,000 480 JCK-9R 200 9R 2540V 11.24 3.0 3.0 Single 80,000 50,000 720 JCK-12R 230 12R 2540V 11.24 3.0 3.0 Single 80,000 50,000 970 JCK-18R 390 18R 2540V 11.24 3.0 3.0 Double 80,000 50,000 1,430 JCK-24R 450 24R 2540V 11.24 3.0 3.0 Double 80,000 50,000 1,880 2400V; R-Rated; Indoor/Enclosure; With Cutler-Hammer Ampgard Hookeye (See Figure 1) JCK-A-2R 70 2R 2540V 11.24 3.0 3.0 Single 80,000 50,000 165 JCK-A-3R 100 3R 2540V 11.24 3.0 3.0 Single 80,000 50,000 220 JCK-A-4R 130 4R 2540V 11.24 3.0 3.0 Single 80,000 50,000 320 JCK-A-5R 150 5R 27540V 11.24 3.0 3.0 Single 80,000 50,000 410 JCK-A-6R 170 6R 2540V 11.24 3.0 3.0 Single 80,000 50,000 480 JCK-A-9R 200 9R 2540V 11.24 3.0 3.0 Single 80,000 50,000 720 JCK-A-12R 230 12R 2540V 11.24 3.0 3.0 Single 80,000 50,000 970 JCK-A-18R 390 18R 2540V 11.24 3.0 3.0 Double 80,000 50,000 1,430 JCK-A-24R 450 24R 2540V 11.24 3.0 3.0 Double 80,000 50,000 1,880 2400V; R-Rated; Indoor/Enclosure; Bolt-On (See Figure 2) JCK-B-30 25 2540V 14.18 12.81 - Single 80,000 50,000 100 JCK-B-2R 70 2R 2540V 14.18 12.81 - Single 80,000 50,000 180 JCK-B-3R 100 3R 2540V 14.18 12.81 - Single 80,000 50,000 270 JCK-B-4R 130 4R 2540V 14.18 12.81 - Single 80,000 50,000 360 JCK-B-5R 150 5R 2540V 14.18 12.81 - Single 80,000 50,000 450 JCK-B-6R 170 6R 2540V 14.18 12.81 - Single 80,000 50,000 540 JCK-B-9R 200 9R 2540V 14.18 12.81 - Single 80,000 50,000 740 JCK-B-12R 230 12R 2540V 14.18 12.81 - Single 80,000 50,000 1,080 JCK-B-18R 390 18R 2540V 14.18 12.81 3.56 Double 80,000 50,000 1,500 JCK-B-24R 450 24R 2540V 14.18 12.81 3.56 Double 80,000 50,000 2,200 2400V; R-Rated; Indoor; Hermetically Sealed, Class 1, Group D, Div. 2, Hazardous Locations; For Use with Ampgard Motor Starters (See Figure 1) JCH-30 25 2540V 11.56 3.0 4.12 Single 80,000 50,000 100 JCH-2R 70 2R 2540V 11.56 3.0 4.12 Single 80,000 50,000 180 JCH-3R 100 3R 2540V 11.56 3.0 4.12 Single 80,000 50,000 270 JCH-4R 130 4R 2540V 11.56 3.0 4.12 Single 80,000 50,000 360 JCH-5R 150 5R 2540V 11.56 3.0 4.12 Single 80,000 50,000 450 JCH-6R 170 6R 2540V 11.56 3.0 4.12 Single 80,000 50,000 540 JCH-9R 200 9R 2540V 11.56 3.0 4.12 Single 80,000 50,000 740 JCH-12R 230 12R 2540V 11.56 3.0 4.12 Single 80,000 50,000 1,080 JCH-18R 390 18R 2540V 11.56 3.0 7.68 Double 80,000 50,000 1,500 JCH-24R 450 24R 2540V 11.56 3.0 7.68 Double 80,000 50,000 2,200 4800V; R-Rated; Indoor/Enclosure (See Figure 1) JCL-2R 70 2R 5080V 15.76 3.0 3.0 Single 80,000 50,000 165 JCL-3R 100 3R 5080V 15.76 3.0 3.0 Single 80,000 50,000 220 JCL-4R 130 4R 5080V 15.76 3.0 3.0 Single 80,000 50,000 320 JCL-5R 150 5R 5080V 15.76 3.0 3.0 Single 80,000 50,000 410 JCL-6R 170 6R 5080V 15.76 3.0 3.0 Single 80,000 50,000 480 JCL-9R 200 9R 5080V 15.76 3.0 3.0 Single 80,000 50,000 720 JCL-12R 230 12R 5080V 15.76 3.0 3.0 Single 80,000 50,000 970 JCL-18R 390 18R 5080V 15.76 3.0 3.0 Double 80,000 50,000 1,430 JCL-24R 450 24R 5080V 15.76 3.0 3.0 Double 80,000 50,000 1,880 Form No. JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B Page 2 of 8 2-26-03 SB03044 Data Sheet: 6001 ® Bussmann JCK, JCK-A, JCK-B, JCH, R-Rated Fuses JCL, JCL-A, JCL-B, For Motor Circuit Protection Medium Voltage JCG, JCR-A, & JCR-B Specifications Buss Maximum Dimensions (Inches) Max. Int. Cap. Min. Int. Cap. Catalog No. Amperage Design Voltage A B C Construction Amps (Asym.) Amps (Sym.) Amps (Sym.) 4800V; R-Rated; Indoor/Enclosure; With Cutler-Hammer Ampgard Hookeye (See Figure 1) JCL-A-2R 70 2R 5080V 15.76 3.0 3.0 Single 80,000 50,000 165 JCL-A-3R 100 3R 5080V 15.76 3.0 3.0 Single 80,000 50,000 220 JCL-A-4R 130 4R 5080V 15.76 3.0 3.0 Single 80,000 50,000 320 JCL-A-5R 150 5R 5080V 15.76 3.0 3.0 Single 80,000 50,000 410 JCL-A-6R 170 6R 5080V 15.76 3.0 3.0 Single 80,000 50,000 480 JCL-A-9R 200 9R 5080V 15.76 3.0 3.0 Single 80,000 50,000 720 JCL-A-12R 230 12R 5080V 15.76 3.0 3.0 Single 80,000 50,000 970 JCL-A-18R 390 18R 5080V 15.76 3.0 3.0 Double 80,000 50,000 1,430 JCL-A-24R 450 24R 5080V 15.76 3.0 3.0 Double 80,000 50,000 1,880 JCL-A-36R 650 36R 5080V 16.0 4.0 - Double 100,000 63,000 3,200 4800V; R-Rated; Indoor/Enclosure; Bolt-On (See Figure 2) JCL-B-30 30 5080V 19.25 17.88 - Single 80,000 50,000 100 JCL-B-2R 70 2R 5080V 19.25 17.88 - Single 80,000 50,000 180 JCL-B-3R 100 3R 5080V 19.25 17.88 - Single 80,000 50,000 270 JCL-B-4R 130 4R 5080V 19.25 17.88 - Single 80,000 50,000 360 JCL-B-5R 150 5R 5080V 19.25 17.88 - Single 80,000 50,000 450 JCL-B-6R 170 6R 5080V 19.25 17.88 - Single 80,000 50,000 540 JCL-B-9R 200 9R 5080V 19.25 17.88 - Single 80,000 50,000 740 JCL-B-12R 230 12R 5080V 19.25 17.88 - Single 80,000 50,000 1,080 JCL-B-18R 390 18R 5080V 19.25 17.88 3.31 Double 80,000 50,000 1,500 JCL-B-24R 450 24R 5080V 19.25 17.88 3.31 Double 80,000 50,000 2,200 4800V; R-Rated; Indoor; Hermetically Sealed, Class 1, Group D, Div. 2, Hazardous Locations; For Use with Ampgard Motor Starters (See Figure 1) JCG-30 30 5080V 16.63.0 4.12 Single 80,000 50,000 95 JCG-2R 70 2R 5080V 16.6 3.0 4.12 Single 80,000 50,000 180 JCG-3R 100 3R 5080V 16.6 3.0 4.12 Single 80,000 50,000 270 JCG-4R 130 4R 5080V 16.6 3.0 4.12 Single 80,000 50,000 350 JCG-5R 150 5R 5080V 16.6 3.0 4.12 Single 80,000 50,000 450 JCG-6R 170 6R 5080V 16.6 3.0 4.12 Single 80,000 50,000 540 JCG-9R 200 9R 5080V 16.6 3.0 4.12 Single 80,000 50,000 700 JCG-12R 230 12R 5080V 16.6 3.0 4.12 Single 80,000 50,000 1,000 JCG-18R 390 18R 5080V 15.85 3.0 6.31 Double 80,000 50,000 1,450 JCG-24R 450 24R 5080V 15.85 3.0 6.31 Double 80,000 50,000 2,000 7200V; R-Rated; Indoor/Enclosure; With Ampgard Hookeye (See Figure 1) JCR-A-2R 70 2R 8300V 15.85 3.0 4.12 Single 80,000 50,000 200 JCR-A-3R 100 3R 8300V 15.85 3.0 4.12 Single 80,000 50,000 320 JCR-A-4R 130 4R 8300V 15.85 3.0 4.12 Single 80,000 50,000 405 JCR-A-5R 150 5R 8300V 15.85 3.0 4.12 Single 80,000 50,000 550 JCR-A-6R 170 6R 8300V 15.85 3.0 4.12 Single 80,000 50,000 670 JCR-A-9R 200 9R 7200V 15.85 3.0 4.12 Single 80,000 50,000 1,300 JCR-A-12R 230 12R 7200V 15.85 3.0 4.12 Single 80,000 50,000 1,500 JCR-A-18R 390 18R 7200V 15.85 3.0 7.43 Double 80,000 50,000 2,000 JCR-A-24R 450 24R 7200V 15.85 3.0 7.43 Double 80,000 50,000 2,600 7200V; R-Rated; Indoor/Enclosure; Bolt-On (See Figure 2) JCR-B-2R 70 2R 8300V 19.25 17.88 - Single 80,000 50,000 200 JCR-B-3R 100 3R 8300V 19.25 17.88 - Single 80,000 50,000 320 JCR-B-4R 130 4R 8300V 19.25 17.88 - Single 80,000 50,000 405 JCR-B-5R 150 5R 8300V 19.25 17.88 - Single 80,000 50,000 550 JCR-B-6R 170 6R 8300V 19.25 17.88 - Single 80,000 50,000 670 JCR-B-9R 200 9R 7200V 19.25 17.88 - Single 80,000 50,000 1,300 JCR-B-12R 230 12R 7200V 19.25 17.88 - Single 80,000 50,000 1,500 JCR-B-18R 390 18R 7200V 19.25 17.88 3.31 Double 80,000 50,000 2,000 JCR-B-24R 450 24R 7200V 19.25 17.88 3.31 Double 80,000 50,000 2,600 Form No. JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B Page 3 of 8 2-26-03 SB03044 Data Sheet: 6001 ® Bussmann R-Rated Fuses JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, For Motor Circuit Protection Medium Voltage JCG, JCR-A, & JCR-B Dimensional Data INDICATOR Showing Fuse is Open 0.38" (9.5mm) C INDICATOR A Showing Fuse is Open B Figure 1 Figure 2 Form No. JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B Page 4 of 8 2-26-03 SB03044 Data Sheet: 6001 ® Bussmann JCK, JCK-A, JCK-B, JCH, R-Rated Fuses JCL, JCL-A, JCL-B, For Motor Circuit Protection Medium Voltage JCG, JCR-A, & JCR-B JCK, JCK-A, JCL, JCL-A Time-Current Characteristic Curves–Minimum Melt Total Clearing Curves 167-A 168-A Current Limitation Curves 184-A PROSPECTIVE SHORT CIRCUIT CURRENT (X10) RMS SYMMETRICAL AMPERES Form No. JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B Page 5 of 8 2-26-03 SB03044 Data Sheet: 6001 INSTANTANEOUS PEAK LET THRU CURRENT AMPERES ® Bussmann R-Rated Fuses JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, For Motor Circuit Protection Medium Voltage JCG, JCR-A, & JCR-B JCK-B, JCH Time-Current Curve: Total Clearing Time-Current Curve: Minimum Melt 50999-1 50999-2 Peak Let-Through Curves 50999-3 PROSPECTIVE SHORT CIRCUIT CURRENT (X10) Form No. JCK, JCK-A, JCK-B, JCH, JCL, RMS SYMMETRICAL AMPERES JCL-A, JCL-B, JCG, JCR-A, & JCR-B Page 6 of 8 2-26-03 SB03044 Data Sheet: 6001 INSTANTANEOUS PEAK LET THRU CURRENT AMPERES ® Bussmann JCK, JCK-A, JCK-B, JCH, R-Rated Fuses JCL, JCL-A, JCL-B, For Motor Circuit Protection Medium Voltage JCG, JCR-A, & JCR-B JCL-B, JCG Time-Current Curve: Total Clearing Time-Current Curve: Minimum Melt 51000-1 51000-2 Peak Let-Through Curves 51000-3 PROSPECTIVE SHORT CIRCUIT CURRENT (X10) RMS SYMMETRICAL AMPERES Form No. JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B Page 7 of 8 2-26-03 SB03044 Data Sheet: 6001 INSTANTANEOUS PEAK LET THRU CURRENT AMPERES ® Bussmann R-Rated Fuses JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, For Motor Circuit Protection Medium Voltage JCG, JCR-A, & JCR-B JCR, JCR-B Time-Current Curve: Total Clearing Time-Current Curve: Minimum Melt 51001-2 51001-1 Peak Let-Through Curves 51001-3 PROSPECTIVE SHORT CIRCUIT CURRENT (X10) RMS SYMMETRICAL AMPERES The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this Data Sheet are by definition uncontrolled. This bulletin is intended to clear- ly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any prod- ucts and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Form No. JCK, JCK-A, JCK-B, JCH, JCL, JCL-A, JCL-B, JCG, JCR-A, & JCR-B Page 8 of 8 2-26-03 SB03044 Data Sheet: 6001 INSTANTANEOUS PEAK LET THRU CURRENT AMPERES
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the JCH-2R?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods