Electronics Finder Manufacturers E EATON BUSSMANN TB8-02
About product Specifications Datasheet FAQ

EATON BUSSMANN TB8-02

Description

Terminal Block Identification Number
TB8-02

Part Number

TB8-02

Price

Request Quote

Manufacturer

EATON BUSSMANN

Lead Time

Request Quote

Category

Connectors »  Connector Terminal Blocks

Specifications

Manufacturer

Eaton Bussmann

Manufacturers Part #

TB8-02

Industry Aliases

TB8-2

Sub-Category

Connector Terminal Blocks

Factory Pack Quantity

500

Datasheet

pdf file

P84662.pdf

664 KiB

Extracted Text

POWERPATH PS-24-8MC POWER BOOSTER POWER SUPPLY Installation Instructions 273 Branchport Avenue, Long Branch, NJ 07740-6899 Ph: (800) 631-2148 Fax: (732) 222-8707 Web Site: www.cooperwheelock.com e-mail: info@cooperwheelock.com A84661-001A Copyright 2007 Cooper Wheelock, Inc. All rights reserved Thank you for using our products. Use this product according to this instruction manual. Please keep this instruction manual for future reference. TABLE OF CONTENTS 1.0 INTRODUCTION AND SPECIFICATIONS: 3 1.1 INTRODUCTION 3 1.2 SPECIFICATIONS 4 1.3 TERMINOLOGY 4 1.4 TERMINAL IDENTIFICATION 5 1.5 LED STATUS 7 1.6 BATTERY MAINTENANCE 7 2.0 INSTALLATION INSTRUCTIONS: 7 2.1 UNPACKING 7 2.2 MOUNTING 7 2.3 WIRING 9 2.4 TROUBLE RELAY STATUS CONNECTIONS 10 2.4.1 AC LOSS TROUBLE TERMINALS 10 2.4.2 COMMON TROUBLE TERMINALS 10 3.0 OPERATION: 12 3.1 MODES OF OPERATION 12 3.2 DIP SWITCH SETTINGS 12 3.3 CLASS “B” OPERATION 13 3.4 CLASS “A” OPERATION WITHOUT OPTIONAL PS-4CA MODULE 16 3.5 CLASS “A” OPERATION WITH OPTIONAL PS-4CA MODULE 20 3.6 MASTER REMOTE OPERATION 24 4.0 TROUBLESHOOTING: 26 5.0 BATTERY CALCULATION SHEET: 27 6.0 WARRANTY STATEMENT: 28 COOPER WHEELOCK INC. COMPATIBLE APPLIANCES: Appendix A LIST OF FIGURES Figure 1: Terminal Locations 6 Figure 2: Mounting Dimensions 8 Figure 3: POWERPATH PS-24-8MC 11 Figure 4: Output DIP Switch(s) 12 LIST OF TABLES Table 1: Terminal Identification 5 Table 2: LED Status Description 7 Table 3: DIP Switch Selection 10 Table 4: Troubleshooting 26 P84662J Page 2 of 28 NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All WARNINGS are printed in bold capital letters. WARNING: READ THIS INSTRUCTION MANUAL CAREFULLY. FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS, AND WARNINGS COULD RESULT IN IMPROPER APPLICATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. 1.0 INTRODUCTION AND SPECIFICATIONS: 1.1 INTRODUCTION The PS-24-8MC POWERPATH is an 8 Amp, 24VDC, filtered and regulated, supervised remote power supply/charger used for supervision and expanded power driving capability for Fire Alarm Notification Appliance Circuits. The PS-24-8MC may be connected to any 12V or 24V (FWR or DC) Fire Alarm Control Panel (FACP) by using a Notification Appliance Circuit (NAC) or a “Dry Contact”. Primary applications include NAC expansion (supports ADA requirements) and auxiliary power to support system accessories. This unit provides filtered and regulated 24VDC, 8 Amp up to four (4) Class "B", two (2) Class “A”, or two (2) Class “B” and one (1) Class “A” Notification Appliance Circuits. With the optional plug-in PS-4CA module 101648 the unit supports (4) Class “A” Notification Appliance Circuits. Additionally, an auxiliary power output of 3.5 Amps (disconnected upon AC power loss or an alarm condition) or 200 mAmps (constant) is provided, which can be manually reset. The PS- 24-8MC also contains a battery charger capable of charging up to 20 Amp/Hour (AH) of battery backup. Batteries larger than 12 AH will not fit inside cabinet, use of an external battery cabinet is necessary. Two FACP NAC circuits or two “Dry” contact initiating circuits can be connected to the POWERPATH inputs. These inputs can then be directed to control supervision and power delivery to any combination of the four (4) outputs. Each output is rated at 3.0 Amps (Class "B") or (Class "A") and can be programmed to generate a steady or Code 3 Temporal Horn sound and a strobe output under alarm condition. Total load for the PS-24-8MC NAC circuits shall not exceed 8.0 Amps. The PS-24-8MC under non-alarmed condition provides independent loop supervision for Class “A” and Class “B” FACP NAC circuits. In the event of a loop trouble, the FACP will be notified via the POWERPATH steered input (IN1 or IN2). In addition there are two sets of trouble reporting terminals, one used for AC power loss reporting and the other for all troubles. The AC power loss reporting, on the common trouble terminals, can be delayed for either 30 seconds or 170 minutes. The AC power loss terminals will always report the trouble, 30 seconds after loss of AC power. Wheelock horns/strobes, strobes and horns with synchronizing capability can be utilized with the PS-24-8MC. Audibles can be silenced with only two wires. Additionally, the POWERPATH can provide a temporal coded signal for appliances that can utilize it. P84662J Page 3 of 28 1.2 SPECIFICATIONS Approvals: • UL Listed 864 Standard for Control Units for Fire Protective Signaling Systems • Pending: FM • Pending: MEA approved – NYC Dept. of Buildings • Pending: California State Fire Marshall (CSFM) approved • Pending: Fire Protection Bureau (FPB) Chicago • NFPA 72 compliant Inputs: • 120VAC, 50/60Hz, 5.0 Amps Operating Power in Alarm • 24VDC Battery Backup Connection • Two (2), 12V or 24V NAC Initiating Circuits (8-33V at 7mA) FWR or DC • Two (2) “Dry” Contact initiating Circuits • Accepts two (2) Class “A” or two (2) Class “B” circuit inputs • Built in battery charger for sealed lead acid or gel type batteries up to a 20 AH. Batteries larger than 12 AH will not fit inside cabinet, use of an external battery cabinet is necessary. Outputs: • NAC outputs are 24VDC, 3.0 Amps each, power limited • 8 Amps total alarm current for the unit • Capable of four (4), Class "B" circuits • Capable of two (2) Class “A” circuits • Capable of four (4) Class “A” circuits (with optional PS-4CA module) • Capable of one (1) Class “A” circuit and two (2) Class “B” circuits • Temporal (Code 3) or constant voltage output generation • Built-in Wheelock synchronization mode that can be fed to any or all of the output circuits nd • Input and output can be synchronized with “IN>OUT SYNC” mode (SM, DSM or 2 PS-24-8MC is required) • Audible silence capability • Filtered and electronically regulated output • 3.5 Amp auxiliary power limited output with reset capability. (Removed upon AC loss or alarm. Automatic reset 30 seconds after AC power returns or the alarm condition is over) or 200 mAmps auxiliary power limited output which remains on during AC loss or an alarm condition. Supervision: • Compatible with 12V or 24V (FWR or DC) FACP • Signaling appliance loops are supervised and steered to either IN1 or IN2 • 2.2K Ohm, 1 Watt (Wheelock Model #MPEOL) End of Line Resistor (EOLR) for supervision of all outputs • AC loss trouble reported over a separate set of contacts (delay of either 30 seconds) • All troubles are reported over the common trouble contacts (AC loss can have a delay of 30 seconds or 170 minutes) • Automatic switchover to standby battery when AC fails • Thermal and short circuit protection with auto reset • Input and output status LED indicators • AC fail supervision • Battery presence and low battery supervision • Ground Fault Detection (60K ohms) 1.3 TERMINOLOGY CLASS “A” = STYLE Z SM = Wheelock Sync Module with single output. CLASS “B” = STYLE Y DSM = Wheelock Dual Sync Module with two outputs. FACP = Fire Alarm Control Panel C = Common EOLR = End of Line Resistor NC = Normally Closed NAC = Notification Appliance Circuit NO = Normally Open AH = Ampere/Hour P84662J Page 4 of 28 1.4 TERMINAL IDENTIFICATION Table 1: Terminal Identification Terminal Block Terminal Function/Description Identification Identification Numbers (Figure 1) TB1-1-3 N,G,L AC power input terminals 120VAC, 50-60Hz. TB5-1, 2 + BAT - 24VDC Battery connection. TB7-1, 2 IN1+,IN1- These terminals connect to the input voltage source (i.e. 12VDC or 24VDC FACP). The FACP will supply a voltage from 8-33V (FWR or DC) at 7mA. During the alarm condition these inputs will cause the designated outputs to drive the notification appliances (designated outputs are set by output DIP switch banks). During Stand-by the PS-24-8MC can report troubles from the designated loop by opening the FACP’s initiation loop. During an alarm condition the PS-24-8MC closes the loop to ensure that the alarm condition will be passed through to the next device on the loop. TB7-3, 4 RET1+, RET1- EOLR is connected on these terminals corresponding to IN1+ and IN1-, or the loop may be continued to other power supplies or appliances before terminating. TB8-1, 2 IN2+, IN2- Same as IN1+, IN1- for corresponding terminals. TB8-5, 4 RET2+, RET2- Same as RET1+, RET1- for corresponding terminals. TB7-5, 6 C “DRY1” NC Dry contacts are used to actuate the designated outputs. Contacts are normally closed and actuate the power supply on contact Open. Designated outputs correspond to IN1+,IN1-. NOTE: Wiring must remain in the same room in conduit. NOTE: FACP NAC circuit cannot energize the power supply by these contacts. NOTE: When these terminals are not in use, a jumper must be connected across them. TB8-5, 6 C “DRY2” NC Operates the same as IN2+,IN2- for corresponding terminals. When these terminals are not in use, a jumper must be connected across them. NOTE: Wiring must remain in the same room in conduit. Indicating appliances are connected to these outputs (See Examples in Operation Section). Each output can supply a maximum load of 3.0 Amps Class "B" or Class "A" and can be individually programmed for TB6-1, 2 +OUT1- Normal Mode, Temporal Mode, IN>OUT SYNC Mode, or WHEELOCK TB6-3, 4 +OUT2- SYNC Mode. The outputs can be configured as four Class "B" circuits, TB6-5, 6 +OUT3- two Class "A" circuits, or two Class "B" and one Class "A" circuits. With TB6-7, 8 +OUT4- the optional PS-4CA module 101648 the unit can provide four Class “A” circuits. Outputs are controlled by a designated input (INPUT 1 or 2) as selected by the DIP switch for that output. NOTE: When the panel has been set to synchronization mode, IN1 is used for strobe activation and IN2 is used for audible silence. Individual output control is disabled. TB4-1-3 “NO” “C” “NC” Typically used to trigger remote alerts or other reporting appliances. (COMMON Form C contacts rated 28VDC at 1 Amp. Resistive TROUBLE OUTPUT) TB2-1-3 “NO” “C” “NC” Used for local reporting of AC power loss to trigger remote alerts or other (AC LOSS reporting appliances. Form C contacts rated 28VDC at 1 Amp. Resistive TROUBLE OUTPUT) TB9-1, 2 + AUX - AUX output is rated 20.1 to 28VDC, special applications. (See Appendix A for suitable devices). In MP mode: AUX output is capable of 3.5Amps, and can be reset by a momentary switch on the board. The 3.5 Amps of power is disconnected when AC power is lost or the unit is in alarm. The 3.5 Amps of power is reconnected 30 seconds after AC power returns or the alarm condition is over. In CP mode: The AUX output is capable of 200mAmps with 12AH battery or 70mAmps with 7AH battery. In CP mode, power is available during AC power loss (batteries connected) and during an alarm condition. P84662J Page 5 of 28 ASSEMBLED IN USA WITH PRIDE TB2 TB4 TB7 Figure 1: Terminal Locations P84662J Page 6 of 28 1.5 LED STATUS Table 2 lists status of the LED indicators. The ALARM condition occurs when the input causes the output circuits to energize. The TROUBLE LED’s for OUT1, OUT2, OUT3, OUT4 and, GND FAULT latch ON when the trouble occurs. They are turned OFF when an alarm condition occurs or the PS-24-8MC system reset switch (SW5) is pressed. The GND FAULT, BATT and, MICRO FAULT LED’s turn ON when the trouble occurs. The trouble relays (AC loss and Common trouble) follow the trouble condition and are non-latching. NOTE: An alarm condition overrides a trouble condition. Table 2: LED Status Description LED OFF ON ON OUT1 STANDBY -------- TROUBLE OUT2 STANDBY -------- TROUBLE OUT3 STANDBY -------- TROUBLE OUT4 STANDBY -------- TROUBLE INP1 STANDBY ALARM TROUBLE* INP2 STANDBY ALARM TROUBLE* GND FAULT -------- TROUBLE -------- AC No AC AC Present -------- BATT -------- TROUBLE -------- MICRO FAULT -------- TROUBLE -------- POWER SUPPLY DC TROUBLE DC PRESENT -------- • NOTE: If INP1 or INP2 LED and OUT1-OUT4 TROUBLE LED are on, TROUBLE exists currently. 1.6 BATTERY MAINTENANCE Replace batteries every four (4) years or as needed if battery will no longer accept full charge, two 12V batteries are required. Battery capacity must be in accordance with the proper battery calculation for the BATTERY CALCULATION SHEET provided on page 27. application using NOTE: Battery compartment measures 4.50" High 12.50" Wide 5.00" Deep. 2.0 INSTALLATION INSTRUCTIONS: NOTE: The PS-24-8MC POWERPATH shall be installed in accordance with the National Fire Protection Association (NFPA), National Electrical Code (NEC) and all applicable state and local regulations. 2.1 UNPACKING The POWERPATH was carefully checked before leaving the factory. Inspect shipping container and unit carefully for indications of improper handling. If damage is detected, make an immediate claim to the carrier. Remove the POWERPATH from the shipping container and check that the door lock keys, door lock, and battery connection wires are inside. Make sure the printed circuit board is securely mounted to the rear of the enclosure. 2.2 MOUNTING WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. CAUTION: This product is not intended for use in hazardous locations as defined by the National Electrical Code (NEC) and by the National Fire Protection Association (NFPA). The POWERPATH unit is to be mounted in an indoor, dry location using the mounting dimensions in Figure 2. Mount the panel in a location that does not exceed a temperature range of 0 C to 49 C (32 F to 120 F) and a humidity equal to 10% to 93% at 30 C (86 F) non-condensing. When mounting on interior walls, use proper screw anchors in plaster. When mounting to concrete, especially when moisture is expected, first attach a piece of ¾ inch plywood to the concrete surface. Attach the POWERPATH to the plywood. P84662J Page 7 of 28 5.00" 7.452" Figure 2: Mounting Dimensions DIMENSIONS (H x W x D) - 16.70” x 12.83” x 5.00” NOTE: All dimensions shown are in inches CAUTION: Use care when punching out knock-outs to avoid damage to internal components. P84662J Page 8 of 28 2.3 WIRING WARNING: MAKE SURE THAT THE TOTAL RMS CURRENT REQUIRED BY ALL APPLIANCES THAT ARE CONNECTED TO THE PS-24-8MC’s NOTIFICATION APPLIANCE CIRCUITS DOES NOT EXCEED THE PS-24-8MC’s RATED CAPACITY (8 AMPS MAXIMUM) OR THE CURRENT RATINGS OF ANY INDIVIDUAL NOTIFICATION APPLIANCE CIRCUIT (3 AMPS MAXIMUM). OVERLOADING THE PS-24-8MC COULD RESULT IN LOSS OF POWER AND FAILURE TO ALERT OCCUPANTS DURING AN EMERGENCY, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Review the Operation Section (3.0) in order to select the proper hook-up and use of the POWERPATH. Set switches and wire the POWERPATH as follows: Terminal and switch locations are shown in Figure 1. A. Set output DIP Switch(s) to follow corresponding input (IN1, IN2) and desired output mode. See Table 3 DIP Switch Selection and DIP Switch Settings Section (3.2). B. Set DIP Switch SW7 position 1 & 2 to select Class “A” or Class “B” operation (Off for Class "B", On for Class "A"). Note: When the PS-24-8MC is used with the optional PS-4CA module, the main board Class switches must be set to Class “B”. C. Select the mode of operation for the Auxiliary output (JP2) to either managed power (MP) or constant power (CP). In the MP mode of operation the Auxiliary output is disconnected upon AC loss or an alarm condition. The power is reconnected 30 seconds after AC power returns or the alarm condition is over. The power is not disconnected when in the CP mode of operation. D. Select the delay, before AC loss trouble will be reported to the common trouble terminals (JP1) to either SHORT DLY or LONG DLY. LONG DLY is 170 minutes and SHORT DLY is 30 seconds. E. If using the optional PS-4CA module install it now. F. Dress the battery wires down to the back of the enclosure, observing ¼” separation of power limited wire V.S. non-power limited wiring. See Figure 3. G. Connect notification appliances to desired outputs OUT1 – OUT4 See Operation Section (3.0). • The POWERPATH has in-out wiring terminals that accept two #18 to #12 American Wire Gauge (AWG) wires at each screw terminal. Strip leads 3/8 inches and connect to screw terminals. Maximum line impedance is 39 ohms or 3.4 volt drop, whichever is more. • Separate all in-out wire runs on supervised circuits to insure integrity of circuit supervision. The polarity shown in the wiring diagrams and on the circuit boards is for operation of the appliances. The polarity is reversed by the FACP during supervision. • Total load for the PS-24-8MC NAC circuits shall not exceed 8.0 Amps. • Total load of any NAC output circuit shall not exceed 3.0 Amps. • In Class “B” mode of operation terminate unused outputs with a 2.2K Ohm EOLR. • In Class “A” mode of operation connect unused outputs to there respective returns. • When using the optional PS-4CA module connect unused outputs to there respective returns. H. Connect the NAC circuit(s) from the FACP to the desired input(s), IN1 and IN2. Connect EOLR to RET1 and RET2. The value is determined by FACP manufacture. I. Connect desired auxiliary equipment to the auxiliary output terminals +AUX-. J. Connect AC loss trouble relay as desired. K. Connect the common trouble relay as desired. L. Connect AC source. The AC source shall be connected to a dedicated, non-switch power source. The AC must first be wired into the buildings main electrical power. The conduit entry can be either from the top or left hand side using the knock-outs. See Figure 3. Connect Earth Ground First. M. Connect backup batteries. Observe correct polarity, use two of the same connected in series. Use either a 7AH or a 12AH battery depending on circuit loading, BATTERY CALCULATION SHEET is provided on Sheet 27. N. Install battery cover between both battery wires and Power Limited Wiring. See Figure 3. O. Press Auxiliary Power Reset, SW6 to ensure that Auxiliary Power is present. P. Close door and lock. P84662J Page 9 of 28 Table 3: DIP Switch Selection Function Switch Position Description Note INPUT ON Selected output to be controlled by Input 1 (IN1+, IN1-) (DRY1) ------ SELECT OFF Selected output to be controlled by Input 2 (IN2+, IN2-) (DRY2) ------ TEMPORAL ON Generates Code 3 temporal signal on this output. 1 IN>OUT SYNC ON Allows a sync signal on the input to be used by the output. ------ WHEELOCK WHEELOCK SYNC “ON” Generates Wheelock sync signal for synchronizing Wheelock horns 2 SYNC MODE IN>OUT SYNC “ON” and strobes. NOTE 1: Use only with appliances that can operate using a coded horn appliance. (Example: Wheelock Series CH, and Series MT) NOTE 2: Use only with Wheelock Series AS/AH, Series NS/NS4/NH, Series RSS and products with SL/SLM strobes. 2.4 TROUBLE RELAY STATUS CONNECTIONS 2.4.1 AC LOSS TROUBLE TERMINALS The AC LOSS TROUBLE TERMINALS are located on the left side of the PC board and used for transmission of local trouble annunciation. The three terminals are labeled “NO”, “C” and “NC”. When the PS-24-8MC is operating normally the “NC” “C” terminals are shorted, and the “C” “NO” terminals are open. This set of terminals reports AC LOSS after a 30 second delay. (Immediate/Short Delay Only). 2.4.2 COMMON TROUBLE TERMINALS The COMMON TROUBLE TERMINALS are located on the left side of the PC Board. The three terminals are labeled “NO”, “C” and “NC”. When the PS-24-8MC is operating normally the “NC” “C” terminals are shorted, and the “C” “NO” terminals are open. There are five trouble conditions that will cause these terminals to change state. • Supervision trouble on any output • Battery Fail (+OUT1-, +OUT2-, +OUT3-, +OUT4-) • Micro Processor Fault • GND Fault • AC Loss When the trouble is cleared the COMMON TROUBLE TERMINALS return to the operating normally condition. AC LOSS reporting on the COMMON TROUBLE TERMINALS can be selected for 30 seconds (Immediate/Short Delay) or 170 minutes (Long Delay). (170 minutes is used for delay of Off-premise trouble annunciation) P84662J Page 10 of 28 TB2 TB4 TB7 Figure 3: POWERPATH PS-24-8MC P84662J Page 11 of 28 3.0 OPERATION: 3.1 MODES OF OPERATION The PS-24-8MC POWERPATH can provide 24VDC output when initiated by a 8V to 33V (FWR or DC) appliance (IN1 or IN2) or an open contact (DRY1 or DRY2). The output will remain on until the deactivation of the input returns it to standby mode. The outputs can be configured as four Class “B” circuits, two Class “A” circuits, or two Class “B” and one Class “A” circuits. With the optional plug in PS-4CA module 101648 the unit supports four Class “A” Notification Appliance Circuits. Each Class "A" circuit or Class "B" circuit is 3.0 Amps. Total load for the PS-24-8MC NAC circuits shall not exceed 8.0 Amps. There are four output modes which can be used with either Class “A” or Class “B” circuits. NORMAL MODE Used for a constant 24VDC output. TEMPORAL MODE Provides a temporal output for appliances that can utilize a coded signal. (i.e. single stroke bells and chimes and some horns) (NOTE: Do not use with Wheelock AS, NS, RSS appliances.) IN>OUT SYNC MODE Allows ONLY a coded signal or Wheelock synchronization signal input to be utilized by the POWERPATH. This signal may come from a FACP, another PS-24-8MC or a Wheelock Synchronization Module (SM-12/24 or DSM-12/24). Audibles can also be silenced. WHEELOCK SYNC MODE Activates the built-in Wheelock Synchronization Mode for use with patented Wheelock synchronized horns and strobes. Audibles can also be silenced. 3.2 DIP SWITCH SETTINGS The following is the DIP Switch settings for the Outputs. When switches are changed, press SYS RESET and wait 10 seconds before activating. Figure 4: Output DIP Switch(s) OUT1-4 IN>OUT SYNC WHEELOCK SYNC TEMPORAL INPUT SELECT ON MODE DIP SWITCH SETTING NORMAL MODE INPUT SELECT (1) “ON” for “IN1” or “DRY1” “OFF” for “IN2” or “DRY2” TEMPORAL (2) “OFF” WHEELOCK SYNC (3) “OFF” IN>OUT SYNC (4) “OFF” TEMPORAL INPUT SELECT (1) “ON” for “IN1” or “DRY1” “OFF” for “IN2” or “DRY2” TEMPORAL (2) “ON” WHEELOCK SYNC (3) “OFF” IN>OUT SYNC (4) “OFF” IN>OUT SYNC INPUT SELECT (1) “ON” for “IN1” or “DRY1” “OFF” for “IN2” or “DRY2” TEMPORAL (2) “OFF” WHEELOCK SYNC (3) “OFF” IN>OUT SYNC (4) “ON” WHEELOCK SYNC INPUT SELECT (1) “ON” for “IN1” or “DRY1” “OFF” for “IN2” or “DRY2” TEMPORAL (2) “OFF” WHEELOCK SYNC (3) “ON” IN>OUT SYNC (4) “ON” P84662J Page 12 of 28 3 4 1 2 4 3 2 1 4 3 2 1 ON ON 1 2 3 4 1 2 3 4 3.3 CLASS “B” OPERATION Class “B” outputs can be controlled from either IN1 or IN2. Switch SW7 position 1 & 2 on the PC board are in the “OFF” position. The following are examples of Class “B” connections. A FACP is used as a representative input. • IN1 and/or IN2 can be used for connection to the FACP. The INPUT SELECT Switch (1) selects which input is to be used to activate the output. • Board switch SW7 position 1 & 2 control Class “A” or Class “B” configuration. SW7 position 1 controls Outputs 1 and 3. SW7 position 2 controls Outputs 2 and 4. • The PS-24-8MC requires a 2.2K Ohm End of Line Resistor (EOLR) on each output for proper supervision. Example 1: NORMAL MODE (CLASS B) + OUT1-4 TO NEXT APPLIANCE IN>OUT SYNC WHEELOCK SYNC OUT1 OR EOLR TEMPORAL + (2.2K OHMS) INPUT SELECT IN1 - ON - + F TO NEXT APPLIANCE TO NEXT APPLIANCE OUT2 OR EOLR + OR EOLR A RET1 (2.2K OHMS) - - + C TO NEXT APPLIANCE POWERPATH OUT3 OR EOLR P (2.2K OHMS) - SW7 + TO NEXT APPLIANCE OUT4 OR EOLR (2.2K OHMS) - LEGEND STROBE AUDIBLE Example 2: TEMPORAL MODE (CLASS B) + TO NEXT APPLIANCE OUT1 OUT1 OR EOLR IN>OUT SYNC + WHEELOCK SYNC IN1 (2.2K OHMS) TEMPORAL - - INPUT SELECT ON F OUT2-4 TO NEXT APPLIANCE IN>OUT SYNC + + OR EOLR WHEELOCK SYNC TO NEXT APPLIANCE RET1 A TEMPORAL - OUT2 OR EOLR INPUT SELECT ON (2.2K OHMS) - C POWERPATH + EOLR P OUT3 - 2.2K OHMS SW7 + EOLR OUT4 - 2.2K OHMS CAUTION: Strobes require constant voltage and will not operate properly in the TEMPORAL MODE. A second output set in the NORMAL MODE will provide the constant voltage. CAUTION: Only use audible appliances that can use a coded signal. Do not use with Wheelock Series AS/AH, NS/NH or HS4/HS appliances. P84662J Page 13 of 28 1 2 3 4 4 3 2 1 ON 4 3 2 1 ON 1 2 3 4 2 3 4 1 Example 3: IN>OUT SYNC MODE from CODED INPUT SOURCE (CLASS B) CODED + + TO NEXT APPLIANCE IN1 OUT1-4 - OUT1 OR EOLR IN>OUT SYNC WHEELOCK SYNC (2.2K OHMS) TO NEXT APPLIANCE TEMPORAL - + INPUT SELECT OR EOLR ON RET1 - F + TO NEXT APPLIANCE A OUT2 OR EOLR + IN2 (2.2K OHMS) - - C POWERPATH + + EOLR P RET2 OUT3 - - 2.2K OHMS SW7 + EOLR OUT4 - 2.2K OHMS Minimum pulse duration for coded signals must be greater than 0.25 seconds. CAUTION: Only use audible appliances that can use a coded signal. Do not use with Wheelock Series AS/AH, NS/NH or HS4/HS appliances. Example 4: IN>OUT SYNC MODE with External Sync Module without Audible Silence (CLASS B) SM/DSM + TO NEXT + IN1 APPLIANCE OUT1-4 - OUT1 + OUT1 IN>OUT SYNC OR EOLR WHEELOCK SYNC TEMPORAL + IN1 - (2.2K OHMS) ON INPUT SELECT F MINUS 1 + EOLR TO NEXT APPLIANCE OUT2 A + - 2.2K OHMS OR EOLR + AUDIBLE RET1 - - AUDIBLE C + EOLR POWERPATH OUT3 P - 2.2K OHMS SW7 + EOLR OUT4 - 2.2K OHMS NOTE: When using the Wheelock external Sync Module (SM or DSM), synchronization will only occur with Wheelock sync appliances. P84662J Page 14 of 28 444 333 222 111 ON 444 333 222 111 ON 1 2 3 4 1 2 3 4 Example 5: IN>OUT SYNC MODE with External Sync Module with Audible Silence (CLASS B) SM/DSM + OUT1-4 TO NEXT APPLIANCE + IN>OUT SYNC OUT1 OR EOLR IN1 WHEELOCK SYNC - + OUT1 TEMPORAL (2.2K OHMS) ON ON ON - INPUT SELECT TO NEXT + IN1 APPLIANCE F + OR EOLR MINUS 1 RET1 + EOLR - OUT2 - 2.2K OHMS A + AUDIBLE EOLR POWERPATH - AUDIBLE C + EOLR OUT3 - 2.2K OHMS P SW7 + EOLR OUT4 - 2.2K OHMS NOTE: When using the Wheelock external Sync Module (SM or DSM), synchronization will only occur with Wheelock sync appliances. Example 6: WHEELOCK SYNC MODE without Audible Silence (CLASS B) + TO NEXT APPLIANCE OUT1-4 + IN1 IN>OUT SYNC OUT1 OR EOLR - WHEELOCK SYNC TEMPORAL (2.2K OHMS) - INPUT SELECT ON ON ON - RET1 + F + EOLR OUT2 - 2.2K OHMS A POWERPATH C + EOLR + IN2 OUT3 - - 2.2K OHMS + P TO NEXT APPLIANCE RET2 - OR EOLR SW7 + EOLR OUT4 - 2.2K OHMS • This mode will only synchronize Wheelock horns, horn strobes, and strobes with the synchronization capability. • If only strobes are connected to the POWERPATH outputs, the initiating input to IN2 is not required. • When synchronized horns are used on the two wire output of the POWERPATH, IN2 must be connected as shown or the horns will not operate. P84662J Page 15 of 28 ON 444 333 222 111 ON 1 4 3 2 4 1 2 3 1 2 3 4 Example 7: WHEELOCK SYNC MODE with Audible Silence (CLASS B) + + TO NEXT APPLIANCE IN1 OUT1-4 - IN>OUT SYNC OUT1 OR EOLR WHEELOCK SYNC TEMPORAL (2.2K OHMS) - ON ON ON INPUT SELECT F TO NEXT APPLIANCE + OR EOLR RET1 + EOLR A - OUT2 - 2.2K OHMS C AUDIBLE POWERPATH SILENCE + + EOLR IN2 P - OUT3 - 2.2K OHMS TO NEXT APPLIANCE + OR EOLR RET2 - SW7 + EOLR OUT4 - 2.2K OHMS • This mode will only synchronize Wheelock horns, horn strobes, and strobes with the synchronization capability. 3.4 CLASS “A” OPERATION WITHOUT OPTIONAL PS-4CA MODULE Class “A” circuit 1 uses “OUT1” and “OUT3”. Class “A” circuit 2 uses “OUT2” and “OUT4”. When operating in Class “A” the two circuits must have the same switch settings for the operational mode selected. Switch SW7 position 1 & 2 on the PC board are in the “ON” position. • IN1 and/or IN2 can be used for connection to the FACP. The INPUT SELECT Switch (1) selects which input is to be used to activate the output. • Board switch SW7 position 1 & 2 control Class “A” or Class “B” configuration. SW7 position 1 controls Outputs 1 and 3. Switch SW7 position 2 controls Outputs 2 and 4. • DIP Switch settings for each circuit in the Class “A” output must be set identically. Example 8: NORMAL MODE (CLASS A) OUT1-4 + + OUT1 IN>OUT SYNC - IN1 WHEELOCK SYNC - TEMPORAL INPUT SELECT ON F TO NEXT APPLIANCE + + OUT2 OR EOLR - RET1 OR RETURN - A TO FACP (CLASS "A") C - POWERPATH OUT3 + P SW7 - OUT4 + P84662J Page 16 of 28 ON ON 4 3 2 1 3 2 1 4 3 2 1 4 3 2 1 4 1 4 3 2 3 2 1 4 4 3 2 1 4 3 2 1 4 1 2 3 1 2 3 4 Example 9: TEMPORAL MODE (CLASS A) OUT1 OUT3 IN>OUT SYNC + + OUT1 WHEELOCK SYNC - IN1 TEMPORAL - INPUT SELECT TO NEXT APPLIANCE ON ON + OR EOLR RET1 OR RETURN OUT2 OUT4 F - TO FACP + IN>OUT SYNC OUT2 - WHEELOCK SYNC (CLASS "A") TEMPORAL A INPUT SELECT ON ON C POWERPATH - OUT3 + P SW7 - OUT4 + CAUTION: Strobes require constant voltage and will not operate properly in the TEMPORAL MODE. A second Class “A” output set in the NORMAL MODE will provide the constant voltage for the strobe circuit. Only use sounding appliances that can use a coded signal. Do not use Wheelock AS/AH or NS/NS4/NH appliances with TEMPORAL MODE. Example 10: IN>OUT SYNC MODE from CODED INPUT SOURCE (CLASS A) OUT1 OUT3 CODED + + IN>OUT SYNC OUT1 - WHEELOCK SYNC IN1 - TEMPORAL TO NEXT APPLIANCE INPUT SELECT ON ON + OR EOLR RET1 OR RETURN F - OUT2 OUT4 + TO FACP OUT2 IN>OUT SYNC - WHEELOCK SYNC (CLASS "A") TEMPORAL A INPUT SELECT ON ON C + - IN2 OUT3 - + P POWERPATH + RET2 - SW9 - OUT4 + Minimum pulse duration for coded signals must be greater than 0.25 seconds. P84662J Page 17 of 28 ON ON 1 4 3 2 4 3 2 1 1 2 3 4 1 2 3 4 Example 11: IN>OUT SYNC MODE with External Sync Module without Audible Silence (CLASS A) SM/DSM + OUT1-4 + IN1 OUT1 - - IN>OUT SYNC + OUT1 WHEELOCK SYNC TEMPORAL + IN1 INPUT SELECT ON F MINUS 1 + OUT2 - A TO NEXT APPLIANCE + + AUDIBLE OR EOLR RET1 - - AUDIBLE C - OUT3 + P POWERPATH SW7 - OUT4 + NOTE: When using the Wheelock external Sync Module (SM or DSM), synchronization will only occur with Wheelock sync appliances. Example 12: IN>OUT SYNC MODE with External Sync Module with Audible Silence (CLASS A) SM/DSM + + OUT1-4 IN1 OUT1 - - IN>OUT SYNC + OUT1 WHEELOCK SYNC TEMPORAL + IN1 INPUT SELECT ON F MINUS 1 AUDIBLE + OUT2 TO NEXT APPLIANCE - SILENCE A + OR EOLR + AUDIBLE RET1 EOLR - - AUDIBLE C - OUT3 POWERPATH + P SW7 - OUT4 + NOTE: When using the Wheelock external Sync Module (SM or DSM), synchronization will only occur with Wheelock sync appliances. P84662J Page 18 of 28 ON ON 1 4 3 2 4 3 2 1 4 1 2 3 1 2 3 4 Example 13: WHEELOCK SYNC MODE without Audible Silence (CLASS A) OUT1-4 + IN>OUT SYNC OUT1 - WHEELOCK SYNC TEMPORAL + INPUT SELECT IN1 - ON - F RET1 + + OUT2 - A POWERPATH C + IN2 - - OUT3 + P TO NEXT APPLIANCE - OR EOLR RET2 OR RETURN + TO FACP SW7 (CLASS "A") - OUT4 + • This mode will only synchronize Wheelock horns, horn strobes, and strobes with the synchronization capability. • If only strobes are connected to the POWERPATH outputs, the initiating input to IN2 is not required. • When synchronized horns are used on the two wire output of the POWERPATH, IN2 must be connected as shown or the horns will not operate. Example 14: WHEELOCK SYNC MODE with Audible Silence (CLASS A) + OUT1-4 IN1 IN>OUT SYNC - + OUT1 WHEELOCK SYNC - TEMPORAL INPUT SELECT ON F TO NEXT APPLIANCE + OR EOLR RET1 + OUT2 OR RETURN - - A TO FACP (CLASS "A") C AUDIBLE SILENCE + POWERPATH IN2 - OUT3 - + P TO NEXT APPLIANCE OR EOLR + RET2 OR RETURN - TO FACP SW7 (CLASS "A") - OUT4 + • This mode will only synchronize Wheelock horns, horn strobes, and strobes with the synchronization capability. COMBINATION CLASS “A” AND CLASS “B” HOOKUP The PS-24-8MC POWERPATH can be configured to have one Class “A” (3.0 Amps) and two Class “B” (3.0 Amps each circuit) outputs at the same time, with a maximum 8 Amps total for the unit. This is done by Switch SW7 position 1 & 2. NOTE: When SW7 position 1 is ON, OUTPUTS 1 and 3 are the Class “A” circuit. When SW7 position 2 is ON, OUTPUTS 2 and 4 are the Class “A” circuit. COMBINATION OF MODES • In Class “B” configuration, each output can be set to an independent mode as desired. • In Class “B”, IN1 or IN2 can be selected to activate any of the outputs desired. • In Class “A”, OUTPUT DIP Switches must be set identically for each Class “A” output. P84662J Page 19 of 28 ON ON 1 2 3 4 1 2 3 4 3.5 CLASS “A” OPERATION WITH OPTIONAL PS-4CA MODULE When using the PS-4CA Class “A” module switch SW7 position 1 & 2 on the board are in the “OFF” position. The following are examples of Class “A” connections with the PS-4CA module. A FACP is used as a representative input. • IN1 and/or IN2 can be used for connection to the FACP. The INPUT SELECT Switch (1) selects which input is to be used to activate the output. Example 15: NORMAL MODE (CLASS A using the PS-4CA module) + + RET1 - IN1 + - OUT1 TO NEXT APPLIANCE - OR EOLR + OR RETURN RET1 F TO FACP + - RET2 (CLASS "A") - + OUT2 A OUT1-4 - IN>OUT SYNC WHEELOCK SYNC TEMPORAL + RET3 C INPUT SELECT ON - + SW7 OUT3 P - + RET4 - + OUT4 - PS-24-8MC PS-4CA LEGEND STROBE AUDIBLE Example 16: TEMPORAL MODE (CLASS A using the PS-4CA module) + + RET1 IN1 - - + OUT1 TO NEXT APPLIANCE - OR EOLR + OR RETURN RET1 TO FACP - (CLASS "A") F + OUT1-4 RET2 IN>OUT SYNC - WHEELOCK SYNC + TEMPORAL OUT2 A INPUT SELECT ON - OUT1 + OUT1-4 RET3 C IN>OUT SYNC - TEMPORAL + INPUT SELECT ON OUT3 OUT2-4 P - SW7 + RET4 - + OUT4 - PS-4CA PS-24-8MC CAUTION: Strobes require constant voltage and will not operate properly in the TEMPORAL MODE. A second output set in the NORMAL MODE will provide the constant voltage. CAUTION: Only use audible appliances that can use a coded signal. Do not use with Wheelock Series AS/AH, NS/NH or HS4/HS appliances. P84662J Page 20 of 28 1 2 3 4 1 2 3 4 1 2 3 4 ON ON 4 1 2 3 4 1 2 3 Example 17: IN>OUT SYNC MODE from CODED INPUT SOURCE (CLASS A using the PS-4CA module) + RET1 + - IN1 - + OUT1 TO NEXT APPLIANCE - + OR EOLR RET1 OR RETURN - TO FACP F + (CLASS "A") RET2 OUT 1-4 - IN>OUT SYNC WHEELOCK SYNC + TEMPORAL OUT2 A INPUT SELECT ON - + RET3 C - + OUT3 P - SW7 + RET4 - + OUT4 - PS-4CA PS-24-8MC Minimum pulse duration for coded signals must be greater than 0.25 seconds. CAUTION: Only use audible appliances that can use a coded signal. Do not use with Wheelock Series AS/AH, NS/NH or HS4/HS appliances. Example 18: IN>OUT SYNC MODE with External Sync Module without Audible Silence (CLASS A using the PS-4CA module) SM/DSM + + RET1 IN1 - - + OUT1 + OUT1 + IN1 - + RET1 F MINUS 1 TO NEXT APPLIANCE - + RET2 OR EOLR - + OUT2 A + AUDIBLE - EOLR IN>OUT SYNC - AUDIBLE WHEELOCK SYNC + TEMPORAL RET3 INPUT SELECT ON - C + OUT1-4 OUT3 - SW7 P + RET4 - + OUT4 - PS-4CA PS-24-8MC NOTE: When using the Wheelock external Sync Module (SM or DSM), synchronization will only occur with Wheelock sync appliances. P84662J Page 21 of 28 1 2 3 4 1 2 3 4 ON ON 2 3 4 1 2 3 4 1 Example 19: IN>OUT SYNC MODE with External Sync Module with Audible Silence (CLASS A using the PS-4CA module) SM/DSM + RET1 - + + OUT1 IN1 - - + OUT1 F TO NEXT APPLIANCE + IN1 + + RET2 OR EOLR RET1 - A MINUS 1 + - OUT2 - OUT1-4 C IN>OUT SYNC + AUDIBLE + WHEELOCK SYNC RET3 TEMPORAL EOLR - INPUT SELECT + - AUDIBLE ON P OUT3 OUT2-4 - SW7 + RET4 - + OUT4 - PS-4CA PS-24-8MC NOTE: When using the Wheelock external Sync Module (SM or DSM), synchronization will only occur with Wheelock sync appliances. Example 20: WHEELOCK SYNC MODE without Audible Silence (CLASS A using the PS-4CA module) + + RET1 - IN1 - + + OUT1 RET1 - - + IN2 - F + RET2 - TO NEXT APPLIANCE + + OR EOLR OR RETURN OUT2 RET2 A - TO FACP - (CLASS "A") OUT1-4 IN>OUT SYNC + WHEELOCK SYNC RET3 C TEMPORAL - + INPUT SELECT ON OUT3 P - SW7 + RET4 - + OUT4 - PS-4CA PS-24-8MC • This mode will only synchronize Wheelock horns, horn strobes, and strobes with the synchronization capability. • If only strobes are connected to the POWERPATH outputs, the initiating input to IN2 is not required. • When synchronized horns are used on the two wire output of the POWERPATH, IN2 must be connected as shown or the horns will not operate. P84662J Page 22 of 28 1 2 3 4 2 3 4 1 ON 1 2 3 4 Example 21: WHEELOCK SYNC MODE with Audible Silence (CLASS A using the PS-4CA module) + RET1 + - IN1 + - OUT1 TO NEXT APPLIANCE + - OR EOLR RET1 OR RETURN - F TO FACP + (CLASS "A") RET2 - + + IN2 OUT2 A - - TO NEXT APPLIANCE + OR EOLR OR RETURN + RET2 C RET3 TO FACP - - (CLASS "A") + OUT1-4 IN>OUT SYNC OUT3 P WHEELOCK SYNC - TEMPORAL INPUT SELECT ON + RET4 SW7 - + OUT4 - PS-4CA PS-24-8MC • This mode will only synchronize Wheelock horns, horn strobes, and strobes with the synchronization capability. P84662J Page 23 of 28 2 3 4 1 1 2 3 4 1 2 3 4 1 2 3 4 3.6 MASTER REMOTE OPERATION Example 22: Synchronized Multiple PS-24-8MC Using a Master PS-24-8MC (in the WHEELOCK SYNC MODE) Without Audible Silence, and Using Input #1. N G L F1 TB1 10 AMP 250V AC AC LOSS TROUBLE TB6 POWER SUPPLY DC NO JP1 C LONG SHORT NC DLY DLY MICRO FAULT OUT 1 INP 1 OUT 2 INP 2 OUT 3 GND FAULT NOTE 2 TROUBLE BATT TB7 OUT 4 TB3 NO OUTPUT 1 ON OFF ON OFF OUTPUT 3 F2 IN>OUT SYNC IN>OUT SYNC C WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL NC INPUT SELECT ON INPUT SELECT 15 AMP FACP ON 32V OUTPUT 2 ON OFF ON OFF OUTPUT 4 IN>OUT SYNC IN>OUT SYNC WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT ON INPUT SELECT ON ON OFF ON OFF SW8 SYS RESET AUX RESET SW7 MP CP SW9 JP2 TB5 TB4 TB9 TB6 IN1+ IN1- RET1+ RET1- C NC IN2+ IN2- RET2+ RET2+ C NC + AUX - + OUT1 - + OUT2 - + OUT3 - + OUT4 - NAC INPUT ALARM CONDITION NOTE 4 NOTE 5 NOTE 7 N G L TB1 F1 10 AMP 250V AC AC LOSS TROUBLE TB6 POWER SUPPLY DC NO JP1 C LONG SHORT DLY MICRO NC DLY FAULT OUT 1 INP 1 OUT 2 INP 2 NOTE 6 GND FAULT OUT 3 TROUBLE TB7 OUT 4 BATT TB3 NO OUTPUT 1 ON OFF ON OFF OUTPUT 3 F2 C IN>OUT SYNC IN>OUT SYNC WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT INPUT SELECT 15 AMP NC ON ON 32V OUTPUT 2 ON OFF ON OFF OUTPUT 4 IN>OUT SYNC IN>OUT SYNC WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT INPUT SELECT ON ON ON OFF ON OFF SW8 SYS AUX RESET RESET SW7 MP CP SW9 JP2 TB4 TB5 TB9 TB6 IN1+ IN1- NC IN2+ IN2- RET2+ NC + AUX - + OUT1 - + OUT2 - + OUT4 - RET1+ RET1- C RET2+ C + OUT3 - NOTE 5 N G L TB1 F1 10 AMP 250V AC AC LOSS TROUBLE TB6 POWER SUPPLY DC NO JP1 C LONG SHORT NC DLY DLY MICRO FAULT OUT 1 INP 1 OUT 2 INP 2 NOTE 6 OUT 3 GND FAULT BATT TROUBLE TB7 OUT 4 TB3 NO ON OFF OUTPUT 1 ON OFF OUTPUT 3 F2 IN>OUT SYNC IN>OUT SYNC C WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT ON INPUT SELECT 15 AMP NC ON 32V OUTPUT 2 ON OFF ON OFF OUTPUT 4 IN>OUT SYNC IN>OUT SYNC WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT ON INPUT SELECT ON ON OFF ON OFF SW8 SYS RESET AUX RESET SW7 MP CP SW9 JP2 TB5 TB9 TB6 TB4 IN1+ IN1- RET1+ RET1- C NC IN2+ IN2- RET2+RET2+ C NC + AUX - + OUT1 - + OUT2 - + OUT3 - + OUT4 - NOTE 5 NOTE 8 See Figure 1 on Sheet 6 for larger view of PC Board. NOTE 1: NAC Input Voltage 8.0V to 33.0V (FWR or DC) Constant. NOTE 2: OBSERVE DIP SWITCH SETTINGS (MASTER) Input Selection DIP Switches (Position 1) on OUT1 to OUT4 are to be set in the "ON" position allowing Input #1 to activate Outputs 1-4, (Positions 2-4) are set for "WHEELOCK SYNC MODE" NOTE 3: Jumper "RET 1-" to "IN 2-" and "RET 1+" to "IN 2+ " only on the Master PS-24-8MC. NOTE 4: Diagram shown with an output circuit (OUT4) on Master POWERPATH used to synchronized the Remote POWERPATHs. NOTE 5: Jumpers must be placed across "DRY 1" and "DRY 2" terminals when operating Power Supply using "IN 1" or "IN 2". NOTE 6: OBSERVE DIP SWITCH SETTINGS (REMOTE) Input Selection DIP Switches (Position 1) on OUT 1 to OUT 4 are to be set in the "ON" position allowing Input #1 to activate Outputs 1-4, (Positions 2-4) are set for "IN>OUT SYNC MODE". NOTE 7: The value of this EOLR is determined by the FACP requirements. NOTE 8: The value of this EOLR is UL Listed 2.2K Ohm P84662J Page 24 of 28 1 2 3 4 1 2 3 4 1 2 3 4 2 3 4 1 2 3 4 1 2 3 4 1 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 + BATT - + BATT - + BATT - ON ON ON 1 2 3 4 1 2 3 4 1 2 3 4 Example 23: Synchronized Multiple PS-24-8MC Using a Master PS-24-8MC (in the WHEELOCK SYNC MODE) With Audible Silence, and Using Input #1 N G L F1 TB1 10 AMP 250V AC AC LOSS TROUBLE TB6 POWER SUPPLY DC NO JP1 C LONG SHORT NC DLY DLY MICRO FAULT OUT 1 INP 1 OUT 2 INP 2 OUT 3 GND FAULT NOTE 2 TROUBLE BATT TB7 OUT 4 TB3 NO OUTPUT 1 ON OFF ON OFF OUTPUT 3 F2 IN>OUT SYNC IN>OUT SYNC C WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL NC INPUT SELECT ON INPUT SELECT 15 AMP FACP ON 32V OUTPUT 2 ON OFF ON OFF OUTPUT 4 IN>OUT SYNC IN>OUT SYNC WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT ON INPUT SELECT ON ON OFF ON OFF SW8 SYS RESET AUX RESET SW7 MP CP SW9 JP2 TB5 TB4 TB9 TB6 IN1+ IN1- RET1+ RET1- C NC IN2+ IN2- RET2+ RET2+ C NC + AUX - + OUT1 - + OUT2 - + OUT3 - + OUT4 - NAC INPUT ALARM CONDITION NOTE 4 NOTE 6 NOTE 5 NOTE 6 N G L TB1 F1 10 AMP 250V AC AC LOSS TROUBLE TB6 POWER SUPPLY DC NO JP1 C LONG SHORT DLY MICRO NC DLY FAULT INP 1 OUT 1 OUT 2 INP 2 NOTE 6 GND FAULT OUT 3 TROUBLE TB7 OUT 4 BATT TB3 NO OUTPUT 1 ON OFF ON OFF OUTPUT 3 F2 C IN>OUT SYNC IN>OUT SYNC WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT INPUT SELECT 15 AMP NC ON ON 32V OUTPUT 2 ON OFF ON OFF OUTPUT 4 IN>OUT SYNC IN>OUT SYNC WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT INPUT SELECT ON ON ON OFF ON OFF SW8 SYS AUX RESET RESET SW7 MP CP SW9 JP2 TB4 TB5 TB9 TB6 IN1+ IN1- NC RET2+ NC + AUX - + OUT1 - + OUT2 - + OUT4 - RET1+ RET1- C IN2+ IN2- RET2+ C + OUT3 - NOTE 5 N G L TB1 F1 10 AMP 250V AC AC LOSS TROUBLE TB6 POWER SUPPLY DC NO JP1 C LONG SHORT NC DLY DLY MICRO FAULT OUT 1 INP 1 OUT 2 INP 2 NOTE 6 OUT 3 GND FAULT BATT TROUBLE TB7 OUT 4 TB3 NO ON OFF OUTPUT 1 ON OFF OUTPUT 3 F2 IN>OUT SYNC IN>OUT SYNC C WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT ON INPUT SELECT 15 AMP NC ON 32V OUTPUT 2 ON OFF ON OFF OUTPUT 4 IN>OUT SYNC IN>OUT SYNC WHEELOCK SYNC WHEELOCK SYNC TEMPORAL TEMPORAL INPUT SELECT ON INPUT SELECT ON ON OFF ON OFF SW8 SYS RESET AUX RESET SW7 MP CP SW9 JP2 TB5 TB9 TB6 TB4 IN1+ IN1- RET1+ RET1- C NC IN2+ IN2- RET2+RET2+ C NC + AUX - + OUT1 - + OUT2 - + OUT3 - + OUT4 - NOTE 5 NOTE 7 See Figure 1 on Sheet 6 for larger view of PC Board. NOTE 1: NAC Input Voltage 8.0V to 33.0V (FWR or DC) Constant. NOTE 2: OBSERVE DIP SWITCH SETTINGS (MASTER) Input Selection DIP Switches (Position 1) on OUT1 to OUT4 are to be set in the "ON" Position allowing Input #1 to activate Outputs 1-4, (Positions 2-4) are set for "WHEELOCK SYNC MODE" NOTE 3: Diagram shown with an output circuit (OUT4) on Master POWERPATH used to synchronize the remote POWERPATHs. NOTE 4: OBSERVE DIP SWITCH SETTINGS (REMOTE) Input Selection DIP Switches (Position 1) on OUT 1 to OUT 4 are to be set in the "ON" Position allowing Input #1 to activate Outputs 1-4, (Positions 2-4) are set for "IN>OUT SYNC MODE". NOTE 5: Jumpers must be placed across “DRY1” and “DRY2” terminals when operating Power Supply using “IN1” or “IN2”. NOTE 6: The value of the EOLR is determined by the FACP requirements. NOTE 7: The value of the EOLR is UL Listed 2.2K Ohms. P84662J Page 25 of 28 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 + BATT - + BATT - + BATT - ON ON ON 4.0 TROUBLESHOOTING: WARNING: THE PS-24-8MC POWERPATH CONTAINS VOLTAGES THAT CAN CAUSE DEATH OR SERIOUS INJURY. ALWAYS OBSERVE PROPER ELECTRICAL SAFETY PRECAUTIONS AND WARNINGS. Always follow good troubleshooting procedures: • AUX power is available after a 20 second delay on power up and when coming out of alarm. • When trouble occurs, observe all visual indications and note them. • If the problem is obvious or it can be located on the Troubleshooting Table, note it. • Press SYS RESET (SW5) and wait 10 seconds check for a trouble indication. • Always de-energize the POWERPATH completely (Remove both AC and DC power) repairs. • While the POWERPATH is de-energized, perform a visual and hands on check of all terminals and wires to ensure proper termination. Table 4: Troubleshooting Trouble Cause Action INP1, INP2 LED’s do not light in No input signal on terminals Check input and input wiring. ALARM. IN1+IN1-, IN2+IN2-. GND FAULT LED ON GND FAULT Check output circuits. DC LED OFF No DC output. Check wiring to AC power source. AC LED OFF No AC power. Check AC power source. No audible output in No input to IN2+,IN2-. See Example 13 and 14 for proper WHEELOCK SYNC MODE. input connections. Horn, horn strobes, or strobes Improper MODE selection Check MODE selection. do not synchronize. Improper appliances. Check appliances to ensure proper type for synchronization. For IN>OUT MODE check input appliance (DSM, SM or PS-24- 8MC). CLASS “A” circuit is not Improper MODE selection or Check to be certain MODE functioning properly. (WITH SW7 settings. selection is identical for each Class OUT OPTIONAL PS-4CA “A” output circuit. Class “A” OUT1 MODULE) uses outputs 1 and 3. Class “A” OUT2 uses outputs 2 and 4. Check SW7 POS 1 and POS 2 on board for “ON” position. CLASS “B” circuit is not Improper MODE selection or Check SW7 POS 1 and POS 2 on functioning properly. SW7 settings. board for “OFF” position. OUT1, OUT2, OUT3, OUT4 Trouble on output. Check output supervision voltage. LED's on during standby. Check output EOLR. CLASS “A” circuit is not Improper MODE selection or Check to be certain MODE functioning properly. (WITH selection is identical for each Class SW7 settings. OPTIONAL PS-4CA MODULE) “A” output circuit. Check SW7 POS 1 and POS 2 on the main board is set to the “OFF” position. P84662J Page 26 of 28 5.0 BATTERY CALCULATION SHEET: PS-24-8MC BATTERY CALCULATION SHEET STANDBY BATTERY CALCULATION Amps 1. The Standby Current for the PS-24-8MC is 0.080 Amps. 2. If in the CP mode of operation enter the AUX current draw (0.060 Amps, 60 hour operation maximum) Amps (0.200 Amps, 24 hour operation maximum) 3. Add Steps 1 and 2 together Amps 4. The number of hours in standby. 24 Hours Standby = 24 60 Hours Standby = 60 Hours 5. Multiply the answer from Step 3 with Step 4 AH 6. If the LONG DELAY is selected for AC Trouble reporting enter 0.29AH otherwise enter 0.00AH. AH 7 Add Step 5 and 6 together for the Total Standby Battery Requirement in Amp Hours. AH ALARM BATTERY CALCULATION 1. List notification appliance requirements. CURRENT ALARM CURRENT FOR THE PS-24-8MC 0.240 NOTIFICATION APPLIANCE 2. Calculate total notification appliance current plus alarm current for PS-24-8MC. Amps 3. Multiply Step 2 by alarm time required for the Alarm Battery Requirement. AH 15 Min : Multiply by 0.25 5 Min : Multiply by 0.0833 TOTAL BACKUP BATTERY REQUIREMENTS 1. Enter Standby Battery Requirement from “STANDBY BATTERY CALCULATION” Step 5. AH 2. Enter Alarm Battery Requirement from “ALARM BATTERY CALCULATION” Step 3. AH 3. Add Steps 1 and 2 together. AH Multiply Step 3 by 1.1 for minimum Backup Battery Requirements. AH P84662J Page 27 of 28 ANY MATERIAL EXTRAPOLATED FROM THIS DOCUMENT OR FROM COOOPER WHEELOCK MANUALS OR OTHER DOCUMENTS DESCRIBING THE PRODUCT FOR USE IN PROMOTIONAL OR ADVERTISING CLAIMS, OR FOR ANY OTHER USE, INCLUDING DESCRIPTION OF THE PRODUCT’S APPLICATION, OPERATION. INSTALLATION AND TESTING IS USED AT THE SOLE RISK OF THE USER, AND COOPER WHEELOCK WILL NOT HAVE ANY LIABILITY FOR SUCH USE. 6.0 WARRANTY STATEMENT: Limited Warranty Cooper Wheelock, Inc. products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained, and operationally tested in accordance with these instructions at the time of installation and at least twice a year or more often in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance, and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), Underwriters’ Laboratories of Canada (ULC), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Cooper Wheelock, Inc. products when properly specified, applied, installed, operated, maintained, and operationally tested as provided above are warranted against mechanical and electrical defects for a period of three years from date of manufacture (as determined by date code). Correction of defects by Cooper Wheelock, Inc providing repairs or a replacement shall be at Cooper Wheelock, Inc.'s sole discretion and shall constitute fulfillment of all warranty obligations. The foregoing limited warranty shall immediately terminate in the event any part not furnished by Cooper Wheelock, Inc. is installed in the product. The foregoing limited warranty specifically excludes any software required for the operation of or included in a product. COOPER WHEELOCK, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY OTHER KIND, EXPRESS, IMPLIED OR STATUTORY WHETHER AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER. Users are solely responsible for determining whether a product is suitable for the user's purposes, or whether it will achieve the user's intended results. There is no warranty against damage resulting from misapplication, improper specification, abuse, accident, or other operating conditions beyond Cooper Wheelock, Inc.'s control. Some Cooper Wheelock, Inc. products contain software. With respect to those products, Cooper Wheelock, Inc. does not warranty that the operation of the software will be uninterrupted or error-free or that the software will meet any other standard of performance, or that the functions or performance of the software will meet the user's requirements. Cooper Wheelock, Inc. shall not be liable for any delays, breakdowns, interruptions, loss, destruction, alteration, or other problems in the use of a product arising out of or caused by the software. The liability of Cooper Wheelock, Inc. arising out of the supplying of a product, or its use, whether based on warranty, negligence, or otherwise, shall not in any case exceed the cost of correcting defects as stated in the limited warranty and upon expiration of the warranty period all such liability shall terminate. Cooper Wheelock, Inc. is not liable for labor costs incurred in removal, reinstallation, or for damage of any type whatsoever, including but not limited to, loss of profit or incidental or consequential damages. The foregoing shall constitute the sole remedy of the purchaser and the exclusive liability of Cooper Wheelock, Inc. In no case will Cooper Wheelock, Inc.'s liability exceed the purchase price paid for a product. Limitation of Liability Cooper Wheelock, Inc.'s liability on any claim of any kind, including negligence, breach of warranty, or otherwise, for any loss or damage resulting from, arising out of, or connected with any contract, or from the manufacture, sale, delivery, resale, repair or use of any product shall be limited to the price applicable to the product or part thereof which gives rise to the claim. Cooper Wheelock, Inc.'s liability on any claim of any kind shall cease immediately upon the installation in the product of any part not furnished by Cooper Wheelock, Inc. In no event shall Cooper Wheelock, Inc. be liable for any claim of any kind unless it is proven that our product was a direct cause of such claim. FURTHER, IN NO EVENT, INCLUDING IN THE CASE OF A CLAIM OF NEGLIGENCE, SHALL COOPER WHEELOCK, INC. BE LIABLE FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the preceding limitation may not apply to all purchasers. 4/07 P84662J Page 28 of 28

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the TB8-02?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Conn Terminal Block Solder ST Thru-Hole 11675-10

product

Conn Power Terminal Blocks F 2 POS 14.2mm Screw Cable Mount 40A 11675-2

product

Conn Distribution Terminal Blocks F 3 POS 14.2mm Screw Cable Mount 40A 11675-3

product

Conn Power Terminal Blocks F 4 POS 14.2mm Screw Cable Mount 40A 11675-4

product

Conn Power Terminal Blocks F 6 POS 14.2mm Screw Cable Mount 40A 11675-6

product

Conn Distribution Terminal Blocks F 2 POS 17.3mm Screw Cable Mount 70A 11725-2