EATON BUSSMANN TR2/TCP2A
Specifications
Manufacturer
Eaton Bussmann
Manufacturers Part #
TR2/TCP2A
Industry Aliases
TR2-TCP2A, TR2/TCP2A
Sub-Category
Fuses
Selling Alternatives
TR2/TCP2-R
Packaging
Tape and Reel
Factory Pack Quantity
2500
Datasheet
Extracted Text
Effective December 2017 Supersedes January 2007 Technical Data 2609 TCP1.25, TCP500 & TCP2 Telecom circuit protector Environmental data • Life Test: MIL-STD-202, Method 108A, Test Condition D • Load Humidity: MIL-STD-202, Method 103B • Moisture Resistance: MIL-STD-202, Method 106E • Thermal Shock: MIL-STD-202, Method 107D, air-to-air • Case Resistance: EIA/IS-722 • Resistance to Dissolution of Metallization: ANSI J-STD-002, Test D • Mechanical Shock: MIL-STD-202, Method 213B, Test Condition A • High Frequency Vibration: MIL-STD-202, Method 204D, TCP1.25 Test Condition D Product features • Resistance to Solvents: MIL-STD-202, Method 215A • The first and most reliable surface mount Agency information telecom circuit protector designed to protect against power cross faults and comply with • UL Recognition Card: JDYX2/E19180 all surge requirements. • CSA Component Certification Record and Class No.: • Allows compliance with telecom regulatory 053787C000, 1422 30 standards including Bellcore GR 1089, UL 1950/60950, and FCC part 68. Ordering code Application circuit testing is recommended. • Eliminates the need for a current limiting • Specify packaging, product and option code (i.e., resistor. TR2-TCP1-25-R) • Protects against overcurrent conditions found in telecom Subscriber Line Interface Soldering method Cards (SLICs), xDSL Modem Applications, • Wave Immersion: 260°C, 10 sec max. Set-Top Boxes, and Consumer Premises • Infrared: 260°C, 30 sec max. Equipment (CPE). • TCP1.25-R tested and confirmed compatible ELECTRICAL CHARACTERISTICS with STMicroelectronics Trisil™ Transient % of Amp Rating Opening Time Surge Arrestor (listed below) 100% 4 Hours Minimum 250% 1 Second Minimum STMicroelectronics Trisil™ P/N’s 250% 4-10 Seconds Typical SMP100LC-XXX SMP100MC-XXX 250%* 120 Seconds Maximum 300% 10 Seconds Maximum * If the device does not open at 250% within 120 seconds, increase current to 300% of amp rating. Device must open in 10 seconds max. mm Land Pattern Dimensions ⁄(inches) 5.2 3.7 (0.204) (0.145) 4.0 (0.157) 12.6 (0.496) TCP1.25, TCP500 & TCP2 Technical Data 2609 Effective December 2017 Telecom circuit protector LIGHTNING SURGE SPECIFICATIONS Surge Specification Surge Repetitions Waveform Current (A) Voltage (V) Performance (μSec.) Requirement FCC 47 Part 68 Longitudinal Type A 2 10x160 100 per fuse 1500 Fuse cannot open FCC 47 Part 68 Metallic Type B 2 10x560 100 800 Fuse cannot open Bellcore GR-1089-CORE First Level Lightning 50 10x1000 100 1000 Fuse cannot open Bellcore GR-1089-CORE First Level Lightning 50 2x10 500 2500 Fuse cannot open Surge out 1 10x160 160 N/A Fuse cannot open Surge out 1 10x560 115 N/A Fuse cannot open ELECTRICAL AND POWER CROSS SPECIFICATIONS Voltage Interrupting DC Cold Typical Maximum Typical Alpha Code Part Rating Rating* Resistance** (ohms) Melting Total Voltage Marking Number 2 AC 250VAC 600VAC min. typ. max. I t† Clearing Drop‡ 1st Code 2nd Code 2 2 250 V 50 A 60 A 0.070 0.090 0.110 22.2 A s 100 A s 150mV J R*** TCP1.25-R * AC Interrupting Rating (Measured at designated voltage, 100% power factor) ** DC Cold Resistance (Measured at 10% of rated current) *** On RoHS Compliant Version (-R option) 2 † Typical Melting I t (Measured with a battery bank at 60V DC, 10x-rated current, time constant of calibrated circuit less than 50 microseconds) ‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes) Special Investigation The TCP1.25-R is designed to provide overcurrent protection for telecom SLIC, xDSL modem, and set-top box applications regardless of the overvoltage device selected. To provide an easier specification experience, Cooper Bussmann and STMicroelectronics have joined together to provide a special test report confirming the coordination between the TCP1.25A and SMP100MC-270 devices. TEST CIRCUITS Fuse TCP 1.25-R Tip L Tip S Fuse TCP 1.25-R L1 SMP100MC-270* T 1 SMP100MC-270* Gnd Gnd L2 T2 SMP100MC-270* Fuse TCP 1.25-R Ring L Ring S Test Circuit 1 Test Circuit 2 * Note: or other STMicroelectronics Trisil™ part number listed in table on page 1 TEST PROGRAM Test Standard Results Lightning Surge Tests 10/1000 µs + and –1kV 100A (25 pulses of each polarity) Bellcore GR-1089 Passed 2/10µs + and –2.5 and 5kV 500A (10 pulses of each polarity) Bellcore GR-1089 Passed 10/560µs + and –800V 100A (1 pulse of each polarity) FCC Part 68 Passed 10/160µs + and –1.5kV 200A (1 pulse of each polarity) FCC Part 68 Passed 10/700µs + and –1.5kV 37.5A (5 pulses of each polarity) K20 Passed Electrical and Power Cross Tests 600V 3A 1.1s (rst le vel) Bellcore GR-1089 Passed 277V 25A (second level) Bellcore GR-1089 Passed 600V 60A 5s(second level) Bellcore GR-1089 Passed 600V 40A 1.5s UL 60950 Passed 600V 2.2A 30min UL 60950 Passed 600V 1A 0.2s (A criteria) K20 Passed 230V 1.44A/0.77A/0.38A 15min (A cr iteria) K20 Passed 230V 23A 15min (A cr iteria) K20 Passed For additional information on STMicroelectronic’s Trisil™ Product line, please see www.st.com/protection www.eaton.com/electronics 2 TCP1.25, TCP500 & TCP2 Technical Data 2609 Telecom circuit protector Effective December 2017 Agency information TCP500 & TCP2 Product features • UL Recognition Card: JDYX2/E19180 • CSA Component Certification Record and Class No.: • Designed to protect Consumer Premises 053787C000, 1422 30 Equipment from harmful overcurrents. • Allows compliance with telecom regulatory Ordering standards including UL 1950/60950, and FCC part 68. Application circuit testing is • Specify packaging, product and option code recommended. (i.e., TR2-TCP500-R) • Eliminates the need for a current limiting resistor. Soldering method • Wave Immersion: 260°C, 10 sec max. • Infrared: 260°C, 30 sec max. Environmental data • Life Test: MIL-STD-202, Method 108A, Test Condition D ELECTRICAL CHARACTERISTICS • Load Humidity: MIL-STD-202, Method 103B % of Amp Rating Opening Time • Moisture Resistance: MIL-STD-202, Method 106E 100% 4 Hours Minimum • Thermal Shock: MIL-STD-202, Method 107D, air-to- 250% 1 Second Minimum air 250% 4-10 Seconds Typical • Case Resistance: EIA/IS-722 250%* 120 Seconds Maximum • Resistance to Dissolution of Metallization: ANSI J- 300% 10 Seconds Maximum STD-002, Test D * If the device does not open at 250% within 120 seconds, increase • Mechanical Shock: MIL-STD-202, Method 213B, Test current to 300% of amp rating. Device must open in 10 seconds max. Condition A • High Frequency Vibration: MIL-STD-202, Method 204D, Test Condition D • Resistance to Solvents: MIL-STD-202, Method 215A mm Dimensions ⁄(inches) Land Pattern 5.2 3.7 (0.204) (0.145) 4.0 (0.157) 12.6 (0.496) LIGHTNING SURGE SPECIFICATIONS Surge Specification Surge Repetitions Waveform Current (A) Voltage (V) Performance (μSec.) Requirement TCP 500mA tested FCC 47 Part 68 Longitudinal Type B 2 5x320 37.5 N/A Fuse cannot open FCC 47 Part 68 Metallic Type A 2 10x560 100 800 Fuse must open safely Surge out 25 10x160 65 N/A Fuse cannot open TCP2A tested FCC 47 Part 68 Longitudinal Type A 2 10x160 100 per fuse 1500 Fuse cannot open FCC 47 Part 68 Metallic Type B 2 10x560 100 800 Fuse cannot open Bellcore GR-1089-CORE First Level Lightning 50 10x1000 100 1000 Fuse cannot open Bellcore GR-1089-CORE First Level Lightning 50 2x10 500 2500 Fuse cannot open Surge out 1 10x160 160 N/A Fuse cannot open Surge out 1 10x560 115 N/A Fuse cannot open ELECTRICAL AND POWER CROSS SPECIFICATIONS Voltage Interrupting DC Cold Typical Maximum Typical Alpha Code Part Rating Rating* Resistance** (ohms) Melting Total Voltage Marking Number 2 AC 250VAC 600VAC min. typ. max. I t† Clearing Drop‡ 1st Code 2nd Code 2 2 250 V 50 A 40 A 0.420 0.530 0.640 1.3 A s 100 A s 471mV F TCP500-R R*** 2 2 250 V 50 A 60 A 0.050 0.075 0.100 30 A s 100 A s 205mV N TCP2-R * AC Interrupting Rating (Measured at designated voltage, 100% power factor) ** DC Cold Resistance (Measured at 10% of rated current) *** On RoHS Compliant Version (-R option) 2 † Typical Melting I t (Measured with a battery bank at 60V DC, 10x-rated current, time constant of calibrated circuit less than 50 microseconds) ‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes) 3 www.eaton.com/electronics TCP1.25, TCP500 & TCP2 Technical Data 2609 Telecom circuit protector Effective December 2017 TIME CURRENT CURVE PACKAGING CODE Packaging Code Description TR2 2,500 pieces of fuses on 24mm tape-and-reel on 13 inch (330mm) reel per EIA Standard 481, 8mm pitch Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Eaton Electronics Division 1000 Eaton Boulevard Cleveland, OH 44122 United States www.eaton.com/electronics © 2017 Eaton All Rights Reserved Eaton is a registered trademark. Printed in USA All other trademarks are property Publication No. 2609 of their respective owners. December 2017
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the TR2/TCP2A?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers





What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods