Description

Switch Toggle ON None ON SPDT Round Lever Solder Lug 5A 125VAC 28VDC Panel Mount with Threads
A123S1CWZG-M8

Part Number

A123S1CWZG-M8

Price

Request Quote

Manufacturer

ELECTROSWITCH

Lead Time

Request Quote

Category

Switches »  Switch Toggle

Specifications

Manufacturer

Electroswitch

Manufacturers Part #

A123S1CWZG-M8

Sub-Category

Toggle Switches

Factory Pack Quantity

1

Datasheet

pdf file

minp4954.pdf

335 KiB

Extracted Text

MINIATURE SWITCHES Commercial Miniature Toggle Switches CURRENT RATINGS SPECIFICATIONS MATERIAL Current Capacity in Amperes — Per Pole Originally designed to meet the Base (body) — Diallyl Phthalate. • • 115 V 125 V requirements of MIL-S-83731 (see Lever — Brass, bright chrome plated. • 28 V AC AC page 54 for Test Specifications). DC 400 Hz 60 Hz Bushing — Brass, nickel plated. • Sealed lever type with panel seal and • Frame — Stainless steel. LAMP LOAD terminal seal. 11 1 Switching Contacts and Rockers — 50 • Flatted bushing on sealed lever type. • millionths gold over silver. RESISTIVE LOAD Solder lug or printed circuit terminals. • Center Terminal — 50 millionths gold 55 5 • over silver. Epoxy sealed terminals. INDUCTIVE LOAD • Hardware — Refer to hardware listing One and two pole circuits. 22 2 • • on page 57. High electrical/mechanical reliability. • LOGIC LEVEL Dry circuit current carrying ability. • 10 mA @ 5 V Max. (AC or DC) Toggle lever throw 25° ±5°. • SWITCH SELECTION TABLE — SEALED Circuit With Lever Catalog Number DOWN UP CENTER Solder Lug Printed Circuit Position Position Position Terminals Terminals "ON-ON-ON" (Flat) CIRCUIT DIAGRAM ONE POLE ON OFF ON A121S1CWZG-M8 A121S1CWCG-M8 ON NONE ON A123S1CWZG-M8 A123S1CWCG-M8 ON NONE ON* A126S1CWZG-M8 A126S1CWCG-M8 No. of ON* OFF ON* A127S1CWZG-M8 A127S1CWCG-M8 Poles Up Center Down ON OFF ON* A131S1CWZG-M8 A131S1CWCG-M8 Position Maintained Position NONE ON ON* A137S1CWZG-M8 A137S1CWCG-M8 Position (Keyway) TWO POLE ON OFF ON A221S1CWZG-M8 A221S1CWCG-M8 ON NONE ON A223S1CWZG-M8 A223S1CWCG-M8 2 ON NONE ON* A226S1CWZG-M8 A226S1CWCG-M8 ON* OFF ON* A227S1CWZG-M8 A227S1CWCG-M8 ON OFF ON* A231S1CWZG-M8 A231S1CWCG-M8 ON ON ON A232S1CWZG-M8 A232S1CWCG-M8 ON ON ON* A233S1CWZG-M8 A233S1CWCG-M8 NONE ON ON* A234S1CWZG-M8 A234S1CWCG-M8 ON* ON ON* A235S1CWZG-M8 A235S1CWCG-M8 * Momentary Contact APPROXIMATE DIMENSIONS SINGLE POLE DOUBLE POLE TERMINAL DIMENSIONS SOLDERING TERMINALS PRINTED CIRCUIT TERMINALS SINGLE POLE DOUBLE POLE SINGLE POLE DOUBLE POLE Litho in U.S.A GG 49 MINIATURE SWITCHES Commercial Miniature Leverlock Toggle Switches — Unsealed SPECIFICATIONS CURRENT RATINGS MATERIAL One hole mounting. Base (body) — Diallyl Phthalate. Current Capacity in Amperes — Per Pole • • 115 V 125 V Originally designed to meet the Locking lever — Brass, nickel plated. • • 28 V AC AC requirements of MIL-S-83731 (see Cap — natural adnodized aluminum DC 400 Hz 60 Hz page 54 for Test Specifications). supplied as standard; other colors LAMP LOAD such as red, blue, gold, black and Slow make, slow break contact action. • 11 1 green are also available. High electrical/mechanical reliability. • RESISTIVE LOAD Bushing — Brass, nickel plated. • Toggle lever throw 25° ±5°. • 55 5 Frame — Stainless steel. Solder lug or printed circuit terminals. • INDUCTIVE LOAD Switching Contacts and Rockers — 50 • One and two pole circuits. millionths gold over silver. • 22 2 Dry circuit current carrying ability. Center Terminal — 50 millionths gold • • over silver. LOGIC LEVEL Mounting hardware furnished unas- • sembled 10 mA @ 5 V Max. (AC or DC) Hardware — Refer to hardware listing • on page 57. LEVER LOCK SELECTION TABLE Circuit With Lever Catalog Number Standard Lever DOWN UP CENTER Solder Lug Printed Circuit Cap Lock Position Position Position Terminals Terminals Style Bushing (Keyway) Style ONE POLE ON OFF ON 1 A121K12KZG-M8 A121K12KCG-M8 ON NONE ON 2 A123K12KZG-M8 A123K12KCG-M8 SPDT ON NONE ON* 3 A126K12KZG-M8 A126K12KCG-M8 ON* OFF ON* 4 A127K12KZG-M8 A127K12KCG-M8 ON OFF ON* 5 A131K12KZG-M8 A131K12KCG-M8 TWO POLE ON OFF ON 1 A221K12KZG-M8 A221K12KCG-M8 ON NONE ON 2 A223K12KZG-M8 A223K12KCG-M8 ON NONE ON* 3 A226K12KZG-M8 A226K12KCG-M8 ON* OFF ON* 4 A227K12KZG-M8 A227K12KCG-M8 ON OFF ON* 5 A231K12KZG-M8 A231K12KCG-M8 ON ON ON 1 A232K12KZG-M8 A232K12KCG-M8 DPDT * Momentary Contact Indicates direction against which lever is locked. APPROXIMATE DIMENSIONS (For terminal dimensions see page 49) SINGLE POLE DOUBLE POLE LEVER LOCK BUSHING STYLES (The descriptive illustrations below are for pictorial representation only — keyway on right hand "ON-ON-ON" side) CIRCUIT DIAGRAM STYLE 1 STYLE 2 STYLE 3 STYLE 4 STYLE 5 No. of Poles UpCenter Down Position Maintained Position Position (Keyway) Locked In Locked Out Of Locked Into Side Locked In Center Locked In Center Three Positions Center Position Opposite Keyway — Position — Momentary Position — Momentary Momentary Keyway Side Either Side Keyway Side 2 50 Litho in U.S.A GG MINIATURE SWITCHES Commercial Miniature Toggle Switches Right Angle Mount (Vertical) P.C. Terminals CURRENT RATINGS SPECIFICATIONS MATERIAL Current Capacity in Amperes — Per Pole Originally designed to meet the Base (body) — Diallyl Phthalate. • • 115 V 125 V requirements of MIL-S-83731 (see Lever — Brass, bright chrome plated. • 28 V AC AC page 54 for Test Specifications). DC 400 Hz 60 Hz Bushing — Brass, nickel plated. • Sealed lever type with panel seal and • Frame — Stainless steel. LAMP LOAD terminal seal. 11 1 Switching Contacts and Rockers — 50 • Right angle mount (vertical) printed • millionths gold over silver. RESISTIVE LOAD circuit terminals. Center Terminal — 50 millionths gold 55 5 • Epoxy sealed printed circuit terminals. • over silver. INDUCTIVE LOAD One and two pole circuits. • Hardware — None required. 22 2 • High electrical/mechanical reliability. • LOGIC LEVEL Dry circuit current carrying ability. • 10 mA @ 5 V Max. (AC or DC) Toggle lever throw 25° ±5°. • SWITCH SELECTION TABLE — SEALED Circuit With Lever In… DOWN UP CENTER Catalog Number Position Position Position (Position C) ONE POLE ON OFF ON A121M1D9AVG-M8 ON NONE ON A123M1D9AVG-M8 ON NONE ON* A126M1D9AVG-M8 ON* OFF ON* A127M1D9AVG-M8 SPDT ON OFF ON* A131M1D9AVG-M8 NONE ON ON* A134M1D9AVG-M8 TWO POLE ON OFF ON A221M1D9AVG-M8 ON NONE ON A223M1D9AVG-M8 ON NONE ON* A226M1D9AVG-M8 ON* OFF ON* A227M1D9AVG-M8 ON OFF ON* A231M1D9AVG-M8 ON ON ON A232M1D9AVG-M8 ON ON ON* A233M1D9AVG-M8 NONE ON ON* A234M1D9AVG-M8 DPDT ON* ON ON* A235M1D9AVG-M8 * Momentary Contact APPROXIMATE DIMENSIONS TERMINAL DIMENSIONS Right Angle P.C. Terminal EPOXY SEAL .031 MAX. TYP. x.050 WIDE SPDT "ON-ON-ON" CIRCUIT DIAGRAM No. of Poles Up Center Down Position Maintained Position Position (Position C) 2 DPDT Litho in U.S.A GG 51 MINIATURE SWITCHES Commercial Miniature Toggle Switches Right Angle Mount (Horizontal) P.C. Terminals CURRENT RATINGS SPECIFICATIONS MATERIAL Current Capacity in Amperes — Per Pole Originally designed to meet the Base (body) — Diallyl Phthalate. • • 115 V 125 V requirements of MIL-S-83731 (see Lever — Brass, bright chrome plated. • 28 V AC AC page 54 for Test Specifications). DC 400 Hz 60 Hz Bushing — Brass, nickel plated. • Sealed lever type with terminal seal. • Frame — Stainless steel. LAMP LOAD Right angle mount (horizontal) printed 11 1 • Switching Contacts and Rockers — 50 • circuit terminals. millionths gold over silver. RESISTIVE LOAD Epoxy sealed printed circuit terminals. • Center Terminal — 50 millionths gold 55 5 • over silver. One and two pole circuits. INDUCTIVE LOAD • Hardware — None required. High electrical/mechanical reliability. 22 2 • • Dry circuit current carrying ability. • LOGIC LEVEL Toggle lever throw 25° ±5°. • 10 mA @ 5 V Max. (AC or DC) SWITCH SELECTION TABLE — SEALED Circuit With Lever In… DOWN UP CENTER Catalog Number Position Position Position (Position C) ONE POLE ON OFF ON A121M1D9AG-M8 ON NONE ON A123M1D9AG-M8 ON NONE ON* A126M1D9AG-M8 ON* OFF ON* A127M1D9AG-M8 SPDT ON OFF ON* A131M1D9AG-M8 NONE ON ON* A134M1D9AG-M8 TWO POLE ON OFF ON A221M1D9AG-M8 ON NONE ON A223M1D9AG-M8 ON NONE ON* A226M1D9AG-M8 ON* OFF ON* A227M1D9AG-M8 ON OFF ON* A231M1D9AG-M8 ON ON ON A232M1D9AG-M8 ON ON ON* A233M1D9AG-M8 NONE ON ON* A234M1D9AG-M8 DPDT ON* ON ON* A235M1D9AG-M8 * Momentary Contact APPROXIMATE DIMENSIONS TERMINAL DIMENSIONS Right Angle P.C. Terminal SPDT "ON-ON-ON" CIRCUIT DIAGRAM No. of Poles Up Center Down Position Maintained Position Position (Position C) 2 DPDT 52 Litho in U.S.A GG MINIATURE SWITCHES Commercial Miniature Toggle Switches – New Four Pole CURRENT RATINGS SPECIFICATIONS MATERIAL Current Capacity in Amperes — Per Pole Originally designed to meet the Base (body) — Diallyl Phthalate. • • 115 V 125 V requirements of MIL-S-83731 (see Lever — Brass, bright chrome plated. • 28 V AC AC page 54 for Test Specifications). DC 400 Hz 60 Hz Locking Lever — Brass, nickel plated. • Sealed lever type with panel seal and • Cap — natural anodized aluminum LAMP LOAD terminal seal. supplied as standard; other colors 11 1 such as red, blue, gold, black and Flatted bushing on sealed lever type. • RESISTIVE LOAD green are also available. Solder lug or printed circuit terminals. • 55 5 Bushing — Brass, nickel plated. • Epoxy sealed terminals. INDUCTIVE LOAD • Frame — Stainless steel. One and two pole circuits. 22 2 • Switching Contacts and Rockers — • High electrical/mechanical reliability. • 50 millionths gold over silver. LOGIC LEVEL Dry circuit current carrying ability. • Center Terminal — 50 millionths gold • 10 mA @ 5 V Max. (AC or DC) Toggle lever throw 25° ±5°. over silver. • Hardware — Refer to hardware listing • on page 57. SWITCH SELECTION TABLE — SEALED APPROXIMATE DIMENSIONS Circuit With Lever In… Catalog Number (For terminal dimensions see page 49) DOWN UP CENTER Solder Lug Printed Circuit Position Position Position Terminals Terminals (Flat) ON OFF ON A421S1CWZG-M8 A421S1CWCG-M8 ON NONE ON A423S1CWZG-M8 A423S1CWCG-M8 ON NONE ON* A426S1CWZG-M8 A426S1CWCG-M8 ON* OFF ON* A427S1CWZG-M8 A427S1CWCG-M8 ON OFF ON* A431S1CWZG-M8 A431S1CWCG-M8 ON ON ON A432S1CWZG-M8 A432S1CWCG-M8 ON ON ON* A433S1CWZG-M8 A433S1CWCG-M8 NONE ON ON* A434S1CWZG-M8 A434S1CWCG-M8 4-PDT ON* ON ON* A435S1CWZG-M8 A435S1CWCG-M8 * Momentary Contact LEVER LOCK SELECTION TABLE — UNSEALED Circuit With Lever In… Catalog Number Standard Lever Cap UP CENTER DOWN Lock Solder Lug Printed Circuit Style Position Position Position Bushing Terminals Terminals (Keyway) Style ON OFF ON 1 A421K12KZG-M8 A421K12KCG-M8 ON NONE ON 2 A423K12KZG-M8 A423K12KCG-M8 ON NONE ON* 3 A426K12KZG-M8 A426K12KCG-M8 ON* OFF ON* 4 A427K12KZG-M8 A427K12KCG-M8 ON OFF ON* 5 A431K12KZG-M8 A431K12KCG-M8 ON ON ON 1 A432K12KZG-M8 A432K12KCG-M8 FOUR POLE "ON-ON-ON" * Momentary Contact Indicates direction against which lever is locked. CIRCUIT DIAGRAM APPROXIMATE DIMENSIONS (For terminal dimensions see page 49) No. of Poles Up Center Down Position Maintained Position Position (Keyway) 4 NOTE: FOR LEVER LOCK BUSHING STYLES SEE PAGE 50. Litho in U.S.A GG 53 MINIATURE SWITCHES Rating, Cross Reference and Engineering Data “A” Series Originally Designed To Meet the Following MIL Specifications MIL Specification Test Requirement 1. Strength of Terminal 1 lb. — solder lug 2. Strength of Actuating Lever 10 lbs. & 8 lbs. throughout range Pivot and Stop 3. Strength of Mounting Means 15 lbs. in. torque on bushing 4. Dielectric (Sea Level) 1000 VAC Group C Indication 750 VAC after electrical endurance. 500 µA max. leakage Dielectric (Altitude) 5. Contact Voltage Drop 2.5 millivolt initial 5.0 millivolt after mechanical endurance @ 2-6 VDC 0.1 amp. 6. Temperature Rise 50°C rise @ rated resistance after endurance test current 7. Short Circuit 10 operations make and carry 100 amps resistive load @ lowest DC volts 8. Mechanical Life 20K operations at specified high and low temperatures 9. Electrical Endurance 10K operations at specified high and low temperatures 10. Overload 50 operations @ 150% of rated resistive load 11. A) Electrical Endurance No requirement at Altitude B) Electrical Endurance 10K operations resistive load @ room temperature at Sea Level 10K operations inductive load @ room temperature 10K operations lamp load @ room temperature Performed on different test samples 12. Vibration Method 204 of MIL-STD-202, test condition A .06 D.A. or 10 G’s 10-500 Hz 10 usec. max. chatter 13. Shock Fuse-method 213 or MIL-STD @75 G’s 10 usec. max, chatter 14. Salt Spray 48 hours — method 101 of MIL-STD-202, test condition B Test Upon Completion 10 operations resistive load (toggle sealed switches only) 15. Moisture Resistance Method 106 of MIL-STD-202 Test Upon Completion 100 VDC potential between current carrying parts and panel 16. Sand & Dust Method 110 of MIL-STD-202, test condition B 6 hours @ 23°C 2.5K operations mechanical life (toggle sealed switches only) 17. Explosion MIL-STD-202 method 109, maximum rated DC inductive load (toggle sealed switches only) 18. Sealing Toggle seal — 5 operations under 0.5 inches of H2O above top of bushing 19. A) Toggle Seal No requirement B) Bushing Seal 20. Temperature Operation Mechanical life, -25°C to +71°C 21. Life Low Cur. Level No requirement 22. Fungus No requirement 23. Intermediate Current 10K operations, 50 milliamps @ 10 VDC resistive load @ 20,000 feet altitude @ room temperature 24. Thermal Shock Method 107 of MIL-STD-202 test condition A 5 cycles @ -55°C/+85°C 54 Litho in U.S.A GG

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the A123S1CWZG-M8?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Switch Toggle ON OFF ON SPDT Locking Lever PC Pins 28VAC 28VDC 0.5VA PC Mount with Threads A121K12KC...

product

Switch Toggle ON OFF ON SPDT Locking Lever Solder Lug 6A 250VAC 28VDC Panel Mount with Threads A121K...

product

Switch Toggle ON OFF ON SPDT Short Bat Lever PC Pins 28VAC 28VDC 0.5VA PC Mount with Bracket A121M1D...

product

Switch Toggle ON OFF ON SPDT Short Bat Lever PC Pins 6A 250VAC 28VDC PC Mount with Bracket A121M1D9A...

product

Switch Toggle ON OFF ON SPDT Short Bat Lever PC Pins 28VAC 28VDC 0.5VA PC Mount with Bracket and Thr...

product

Switch Toggle ON OFF ON SPDT Short Bat Lever PC Pins 6A 250VAC 28VDC PC Mount with Threads A121M1DCQ...