HONEYWELL BME6-2RN
Specifications
Manufacturer
Honeywell
Manufacturers Part #
BME6-2RN
Industry Aliases
BME6-2RN
Sub-Category
Limit Switches
Brand
Micro Switch
Factory Pack Quantity
1
Datasheet
Extracted Text
MICRO SWITCH™ Medium-Duty Limit Switches E6/V6 Series Datasheet MICRO SWITCH™ E6/V6 Series Medium-Duty Limit Switches Honeywell MICRO SWITCH™ E6/V6 Series medium-duty limit switches are designed for a wide variety of indoor and outdoor applications. Typical applications include equipment for commercial, industrial, transportation, and agriculture industries. The electrostatic applied epoxy coating to the zinc housings enhance the durability of the product in most environments. The E6/V6 family of switches incorporates the Honeywell MICRO SWITCH™ BZ switch element which has the reliable snap-spring mechanism with more than 60 years of proven service. The sealed (actuators with boots) E6/V6 Series switches are preferred for applications where there could be exposure to liquid and/or particulate environments. The general purpose (actuators without boot seals) E6/V6 Series switches are ideal for applications where there will not be exposure to liquid or dust environments. The compact size of these limit switches permits installation where there is limited space available on equipment. Most SPDT (Single Pole Double Throw) E6/V6 catalog listings are certified to UL, CSA, and CE while the DPDT (Double Pole Double Throw) E6/V6 catalog listings are certified to UL and CSA. What makes our switches better? Designed with MICRO SWITCH™ BZ, BM, or DT basic switches to deliver precise switching of electrical and mechanical operating characteristics High capacity (22 A) available with BME6 Series switch Small footprint with easy access to wiring terminals Available in a configuration suited to the application with variety of actuators, circuitries, connectivities, and mounting options HIGH PERFORMANCE • DURABILITY CUSTOMIZATION • EASY TO INSTALL sensing.honeywell.com 2 DESIGNED FOR DEMANDING ENVIRONMENTS AND F Fe ea at tu ur re es s APPLICATIONS a an nd d Be Ben ne efit fits s MICRO SWITCH™ E6/V6 Series switches feature an electrostatic epoxy coated zinc housing for durability in most indoor and outdoor environments, and a wide variety of actuators to solve most application requirements. Side and flange mounting options RELIABLY HANDLES ELECTRICAL LOADS The E6/V6 Series are available with SPDT contacts with momentary or maintained action, or DPDT contacts with momentary action. These switches also offer gold- plated switch contacts for logic-level circuits and silver alloy contacts for power duty circuits. The internal ground screw is provided to meet electrical codes as required. DESIGN FLEXIBILITY These limit switches are offered with multiple connectivity options: three different conduit offerings, four-pin “mini” style connector, pre-wired 16-gage four- conductor cable, pigtail with three-pin Deutsch connector. GLOBAL APPROVALS E6/V6 Series switches are UL, CSA, and CE certified for most SPDT catalog listings. The DPDT catalog listings are UL and CSA certified. LOW TEMPERATURE OPTIONS The E6/V6 Series’ standard temperature range is -32 °C to 71 °C [-25 °F to 160 °F] with an optional -40 °C [-40 °F] low temperature. sensing.honeywell.com 3 Figure 1. MICRO SWITCH™ E6 Side Mount and V6 Flange Mount with Features and Options Stainless steel roller Wide choice of actuators and operating characteristics Diaphragm boot seal for long life Single or double pole switches Rugged zinc housing and cover are phosphate treated and epoxy coated for environmental durability Multiple conduit options for ease of Popular 25,4 mm [1 in] mounting pattern connectivity Terminal screws of switch easily accessed with cover removed Captive cover screws (2) Internal ground screw provided in cover Cover with one-piece molded insulator seal Figure 1A. E6 Side mount with boot sealed actuator (typical) Wide choice of actuator styles and Hardened steel plunger for long life operating characteristics Rugged zinc housing and cover phosphate treated and electrostatic epoxy coated for environmental durability Single or double pole switches Multiple conduit options for ease of connectivity Terminal screws of switch easily accessed with cover removed Captive cover screws (2) Internal ground screw provided in cover Optional ange base mounting Cover with one-piece molded insulator seal Figure 1B. V6 Flange mount without boot sealed actuator (typical) sensing.honeywell.com 4 Potential Applications INDUSTRIAL • Packaging equipment (balers, door interlocks) • Air curtains (control of air movement) • Conveyors (diverters, gates) TRANSPORTATION • Construction machinery and equipment (door and panel interlocks) • Rail maintenance equipment (door and panel interlocks, position sensing) • Agricultural equipment (grain handling) Table 1. Specifications Characteristic Parameter top pin plunger (with and without boot seal) top roller plunger, parallel with long axis of switch (with and without boot seal) cross roller plunger, perpendicular with long axis of switch (with and without boot seal) manually operated (with boot seal) Actuators roller arm, adjustable (with and without boot seal) one-way roller lever (with boot seal) low-force rod lever (with and without boot seal) wobble (with boot seal) manual reset switches: top pin plunger, top roller plunger, adjustable roller arm, wobble Housing material electrostatic epoxy coated zinc die-cast Termination see table 2 below actuator with boot seal: NEMA 1, 3, 4, IP66 Sealing actuator without seal boot: NEMA 1, IP40 SPDT (snap-action contacts, 1NO/1NC) Switching options SPDT-DB (double break snap-action contacts, 1NO/1NC) DPDT (snap-action contacts, 2NO/2NC) Mechanical endurance up to five million cycles for BZx6 and BMx6 switches; up to two million cycles for DTx6 switches Electrical endurance up to 50K cycles at full rated load -32 °C to 71 °C [-25 °F to 160 °F] (standard) Operating temperature -40 °C to 71 °C [-40 °F to 160 °F] (optional low temperature) Agency approvals UL, CSA, CE Table 2. Terminations Catalog Listing Suffixes Description none 0.5 - 14 NPT conduit thread S 0.5 - 14 NPSM conduit thread M M20 - 1,5 mm conduit thread R four-pin “mini” style connector F1 305 mm [12 in] pigtail STOW-A, three conductor, 16-gage cable with three-pin Deutsch connector F3 914 mm [36 in] 16-gage, four-conductor STO, PVC jacketed cable sensing.honeywell.com 5 E6/V6 Series Table 3. Electrical Ratings Rating Code UL, CSA Rating CE Rating 15 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac; EN60947-5-1, IEC60947-5-1 A 1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac; AC15, B300 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc 10 A @ 125 Vac, 250 Vac B – 0.3 A @ 125 Vdc, 0.15 A @ 250 Vdc 15 A @125 Vac, 250 Vac or 480 Vac; EN60947-5-1, IEC60947-5-1 C 1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac; AC15, B300 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc 8 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac; EN60947-5-1, IEC60947-5-1 D 1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac; AC15, B300 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc 10 A @ 125 Vac, 250 Vac or 480 Vac; 2 A @ 600 Vac; EN60947-5-1, IEC60947-5-1 E 1/8 HP @ 125 Vac, 1/4 HP @ 250 Vac; AC15, B300 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc 15 A @125 Vac, 250 Vac or 480 Vac; EN60947-5-1, IEC60947-5-1 F 1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac; AC15, B300 1.0 A @ 125 Vdc, 0.5 A @ 250 Vdc 22 A @125 Vac, 250 Vac or 480 Vac; G 1/4 HP @ 125 Vac, 1/2 HP @ 250 Vac; – 0.5 A @ 125 Vdc, 0.25 A @ 250 Vdc IEC 61058-1 H 1A @ 125 Vac (Gold-plated contacts) 1A, 250 Vac Table 4. CE Electrical Rating, EN60947-5-1, IEC 60947-5-1 Designation & Continuous Vac Amps Make Amps Break VA Rating Make VA Rating Break Category Current (A) AC15, B300 120 30 3.0 5 3600 360 AC15, B300 240 15 1.5 5 3600 360 Table 5. Switching SPDT DPDT SPDT-DB NC C NC NO NC NC C NO NC NO NO C NO sensing.honeywell.com 6 MICRO SWITCH™ Medium-Duty Limit Switches PRODUCT NOMENCLATURE BZ E6 — 2 R N Actuator Additional Internal Basic Enclosure Plunger 3 Switch Type Contact Modifications Modifications Type Switch Construction Type BZ Series For use with “X” actuator, 0.5-14 NPT Standard 2 Pin plunger Side mount Seal boot E6 maintained contact R N conduit thread (Single-break) (blank) Basic Switch (blank) (blank) SPDT, 15 A Maintained Pre-leaded, 3 ft Double-break Flange mount Standard No seal boot contact with cable, conduit V6 Q C3 2 A X (BZ basic switch only) 2 reset plunger area epoxy sealed 12-inch pigtail DT Series Adjustable 2 cable with 3-pin Special 7 2 F1 roller lever Deutsch connect. Basic Switch DPDT, 10 A Manual, palm Epoxy sealed, NOTE: 4 F3 button 3 ft of cable 1. Not all combinations of model codes are available. Contact your Honeywell rep or distributor for assistance. BM Series Epoxy sealed, #8 mounting 2. BZ Series only. 7 F5 screws 5 ft of cable 3. More than one actuator modification may be permissible. Basic Switch For example, BZE6-2RN8034 is a roller plunger with low temperature seals. Epoxy sealed, SPDT, 22 A 8 Roller plunger F6 6 ft of cable 80 Epoxy sealed, Coil spring 4-pin “mini style” FR 18 wobble stick connector One-way 4-pin “mini style” R 28 roller lever connector 1/4-14 NPSM Low temp. 34 S conduit threads M20 x 1,5 mm Rod M conduit thread 62 lever 72 Gold-contact switch 722 Cross 81 roller plunger sensing.honeywell.com 7 E6/V6 Series Table 6. Order Guide • E6 Series Switches, Side Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Catalog Listing Comments BZ, A, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 BZE6-2RN SPDT 15 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] 12 in. pigtail, 3 BZ, E, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 BZE6-2RN-F1 wire STO cable w/ SPDT 10 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] Deutsch connector Epoxy sealed with BZ, E, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 BZE6-2RN-F3 36 in. 4 wire STO SPDT 10 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] cable BZ, A, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 M20-1,5 conduit BZE6-2RN-M SPDT 15 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] thread BZ, D, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 4-pin "mini" style BZE6-2RN-R SPDT 8 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] connector BZ, A, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 0.5-14 NPSM BZE6-2RN-S SPDT 15 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] conduit thread BZ, A, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 BZE6-2RN7 #8 mounting screws SPDT 15 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] Pin Plunger BZ, A, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 Low temperature BZE6-2RN34 SPDT 15 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] -40 °C [-40 °F] BZ, H, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 Gold-plated BZE6-2RN72 SPDT 1 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] contacts BZ, SPDT, F, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 Recommended for BZE6-2AN Double 15 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] dc applications break BM, G, 2,50 to 6,67 43,66 ±0,76 1,98 5,56 0,05 Higher current ac BME6-2RN SPDT 22 A [9 to 24] [1.719 ±0.030] [0.078] [0.219] [0.002] applications DT, B, 7,23 to 16,4 46,02 ±0,76 2,80 3,17 1,52 Double pole DTE6-2RN DPDT 10 A [26 to 59] [1.812 ±0.030] [0.110] [0.125] [0.060] applications BZ, A, 2,50 to 6,67 56,7 ±1,14 1,98 5,56 0,05 BZE6-2RN80 SPDT 15 A [9 to24] [2.232 ±0.045] [0.078] [0.219] [0.002] BZ, A, 2,50 to 6,67 56,7 ±1,14 1,98 5,56 0,05 Low temperature BZE6-2RN8034 SPDT 15 A [9 to24] [2.232 ±0.045] [0.078] [0.219] [0.002] -40 °C [-40 °F] DT, B, 5,56 to 13,3 59,6 ±1,0 2,80 3,17 1,52 Double pole DTE6-2RN80 DPDT 10 A [20 to 48] [2.345 ±0.040] [0.110] [0.125] [0.060] applications Low temp. -40 °C Inline Roller Plunger DTE6- DT, B, 5,56 to 13,3 59,6 ±1,0 2,80 3,17 1,52 [-40 °F], M20 -1,5 2RN8034-M DPDT 10 A [20 to 48] [2.345 ±0.040] [0.110] [0.125] [0.060] conduit, Double pole applications BZ, A, 2,50 to 6,67 56,7 ±1,14 1,98 5,56 0,05 BZE6-2RN81 SPDT 15 A [9 to24] [2.232 ±0.045] [0.078] [0.219] [0.002] Cross Roller Plunger sensing.honeywell.com 8 Switch type, Circuitry Electrical Rating [page 6] Operate Force N [oz] Operate Point mm [in] Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. MICRO SWITCH™ Medium-Duty Limit Switches Table 6, continued. Order Guide • E6 Series Switches, Side Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Catalog Listing Comments BZ, A, 2,78 to 5,57 71,42 Ref 4,83 5,56 0,15 BZE6-2RN2 SPDT 15 A [10 to 20] [2.812] [0.188] [0.219] [0.006] BZ, A, 2,78 to 5,57 71,42 Ref 4,83 5,56 0,15 0.5-14 NPSM BZE6-2RN2-S SPDT 15 A [10 to 20] [2.812] [0.188] [0.219] [0.006] conduit thread BZ, A, 2,78 to 5,57 71,42 Ref 4,83 5,56 0,15 Low temperature BZE6-2RN234 SPDT 15 A [10 to 20] [2.812] [0.188] [0.219] [0.006] -40 °C [-40 °F] BZ, H, 2,78 to 5,57 71,42 Ref 4,83 5,56 0,15 Gold-plated BZE6-2RN272 SPDT 1 A [10 to 20] [2.812] [0.188] [0.219] [0.006] contacts Roller Lever DT, B, 2,78 to 8,35 69,44 Ref 6,76 5,56 4,19 Double pole DTE6-2RN2 DPDT 10 A [10 to 30] [2.734] [0.266] [0.219] [0.165] applications BZ, A, 2,22 to 5,56 5,94 5,56 0,15 BZE6-2RN28 - SPDT 15 A [8 to 20] [0.234] [0.219] [0.006] BZ, A, 2,22 to 5,56 5,94 5,56 0,15 0.5-14 NPSM BZE6-2RN28-S - SPDT 15 A [8 to 20] [0.234] [0.219] [0.006] conduit thread DT, B, 5,56 to10 7,92 5,56 4,19 Double pole DTE6-2RN28 - One-way Roller DPDT 10 A [20 to 36] [0.312] [0.219] [0.165] applications Lever BZ, A, 0,83 to 1,95 18,24 21,29 5,82 BZE6-2RN62 - SPDT 15 A [3 to 7] [0.718] [838] [0.229] Low-force Rod Lever 1,95 N max. BZ, A, BZE6-2RN18 [7.0 oz - 15° 20° Ref - SPDT 15 A max.] 1,95 N max. BZ, H, Gold-plated BZE6-2RN1872 [7.0 oz - 15° 20° Ref - SPDT 1 A contacts max.] Coil-spring Wobble BZ, A, 2,78 to 5,57 4,83 5,56 0,15 BZE6-2RN4 80,0 Ref [3.15] SPDT 15 A [10 to 20] [0.188] [0.219] [0.006] Manual Palm Button sensing.honeywell.com 9 Switch type, Circuitry Electrical Rating [page 6] Operate Force N [oz] Operate Point mm [in] Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. E6/V6 Series Table 6. continued. Order Guide • E6 Series Switches, Side Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Catalog Listing Comments BZ, A, 1,67 to 5,56 43,64 ± 0,76 1,98 5,56 Reset position: BZE6-RNX1 NA SPDT 15 A [6 to 20] [1.718 ±0.030] [0.078] [0.219] 53,19 [2.094] max. Pin Plunger w Manual Reset 56,70 ± 1,14 BZ, A, 5,85 to 15,57 1,98 4,75 Reset position: BZE6-RN80X2 [2.232 ± NA SPDT 15 A [21 to 56] [0.078] [0.187] 53,19 [2.094] max. 0.045] Inline roller plunger w/ manual reset Reset position: BZ, A, 4,45 N max. 71,42 Ref 4,83 5,56 BZE6-RN2X1 NA 50,40 ± 1,14 SPDT 15 A [16 oz max.] [2.812 in.] [0.188] [0.219] [1.984 ± 0.045] Roller Lever w/ Manual Reset Reset position: BZ, A, 1,95 N max. BZE6-RN18X1 - 15° 20° Ref NA 50,40 ± 1,14 SPDT 15 A [7.0 oz max.] [1.984 ± 0.045] Coil Spring Wobble w/ Manual Reset sensing.honeywell.com 10 Switch type, Circuitry Electrical Rating [page 6] Operate Force N [oz] Operate Point mm [in] Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. MICRO SWITCH™ Medium-Duty Limit Switches DIMENSIONS Figure 2. Top pin plunger, side mount with boot seal Figure 3. Top roller plunger, side mount with boot seal Ø 8,44 mm ref. 2,0 mm 23,4 mm Ø12,7 mm [0.50 in] x [Ø 0.33 in] [0.92 in] [ref. 0.08 in] 4,6 mm [0.18 in] W roller 1/2-14 NPT 56,64 mm Threads 43,7 mm OP 1/2-14 NPT [2.23 in] [1.72 in OP] Threads 25,4 mm 22,6 mm [1.00 in] [0.89 in] 25,4 mm 22,6 mm [1.00 in] 25,4 mm [1.00 in] [0.89 in] 25,4 mm 77,2 mm [1.00 in] [3.04 in] 25,4 mm 25,4 mm [1.00 in] 21,1 mm 69,6 mm [1.00 in] [0.83 in] [2.74 in] 21,1 mm [0.83 in] Figure 4. Cross roller plunger, side mount with boot seal Figure 5. Roller lever, adjustable, side mount with boot seal Ø 19,0 mm [0.75 in] x Ø12,7 mm [0.50 in] x 6,4 mm [0.25 in] W 4,6 mm [0.18 in] W 39,6 mm roller roller [1.57 in] 18,3 mm [0.72 in] 56,64 mm 1/2-14 NPT 23,1 mm [2.23 in] Threads [0.91 in] 53,1 mm 1/2-14 NPT [2.09 in] 25,4 mm Threads 22,6 mm [1.00 in] [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 25,4 mm 22,6 mm 77,2 mm [3.04 in] [1.00 in] [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] Figure 7. Rod lever, side mount with boot seal Figure 6. One-way roller lever, side mount with boot seal 152,4 mm [6.0 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W 18,3 mm roller [0.72 in] 18,3 mm [0.72 in] 32,26 mm [1.27 in] 53,1 mm 1/2-14 NPT [2.09 in] Threads 53,1 mm 1/2-14 NPT [2.09 in] Threads 25,4 mm 22,6 mm [1.00 in] 25,4 mm [0.89 in] 22,6 mm [1.00 in] [0.89 in] 25,4 mm [1.00 in] 25,4 mm 25,4 mm [1.00 in] 69,6 mm [2.74 in] [1.00 in] 69,6 mm [2.74 in] 25,4 mm 77,2 mm [3.04 in] 77,2 mm [3.04 in] [1.00 in] sensing.honeywell.com 11 39,6 mm [1.56 in] 19.0 mm [0.75 in] 19.0 mm 19.0 mm [0.75 in] [0.75 in] 19.0 mm 19.0 mm 19.0 mm [0.75 in] [0.75 in] [0.75 in] E6/V6 Series Figure 8. Manual palm button, side mount with boot seal Figure 9. Coil wobble, side mount with boot seal Ø 7,11 mm [Ø 0.28 in] 38,1 mm 18,3 mm [1.50 in] [0.72 in] 108,97 mm [4.29 in] 31,75 mm [1.25 in] 149,35 mm [5.88 in] 1/2-14 NPT 53,1 mm Threads 1/2-14 NPT [2.09 in] Threads 25,4 mm 22,6 mm [1.00 in] 25,4 mm [0.89 in] 22,6 mm [1.00 in] [0.89 in] 25,4 mm [1.00 in] 25,4 mm 69,6 mm [2.74 in] [1.00 in] 25,4 mm [1.00 in] 25,4 mm 77,2 mm [3.04 in] 69,6 mm [2.74 in] [1.00 in] 77,2 mm [3.04 in] Figure 10. Top pin plunger, reset, side mount with boot seal Figure 11. Top roller plunger, reset, side mount with boot seal Ø 8,44 mm Ø12,7 mm [0.50 in] x [Ø 0.33 in] 4,6 mm [0.18 in] W roller 56,64 mm 1/2-14 NPT 1/2-14 NPT [2.23 in] Threads Threads 22,6 mm 22,6 mm [0.89 in] [0.89 in] 25,4 mm 25,4 mm 25,4 mm 25,4 mm [1.00 in] [1.00 in] [1.00 in] [1.00 in] 69,6 mm [2.74 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 77,2 mm [3.04 in] Figure 12. Roller lever plunger, reset, side mount with boot seal Figure 13. Coil wobble plunger, reset, side mount with boot seal Ø 7,11 mm [Ø 0.28 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W 39,6 mm roller [1.57 in] 18,3 mm 108,97 mm [0.72 in] [4.29 in] 23,1 mm [0.91 in] 149,35 mm [5.88 in] 53,1 mm 1/2-14 NPT 1/2-14 NPT [2.09 in] Threads Threads 22,6 mm 22,6 mm [0.89 in] [0.89 in] 25,4 mm 25,4 mm 25,4 mm 25,4 mm [1.00 in] [1.00 in] [1.00 in] [1.00 in] 69,6 mm [2.74 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 77,2 mm [3.04 in] sensing.honeywell.com 12 36,58 mm [1.44 in] 53,1 mm [2.09 in] 53,1 mm [2.09 in] 43,69 mm [1.72 in] 25,4 mm 25,4 mm 19.0 mm 19.0 mm [1.00 in] [1.00 in] [0.75 in] [0.75 in] 19.0 mm [0.75 in] 53,1 mm [2.09 in] 53,1 mm [2.09 in] 25,4 mm 25,4 mm 19.0 mm [1.00 in] 19.0 mm [1.00 in] [0.75 in] [0.75 in] 19.0 mm [0.75 in] MICRO SWITCH™ Medium-Duty Limit Switches Table 7. Order Guide • E6 Series Switches, Side Mount without Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Catalog Listing Comments BZ, A, 2,50 to 3,61 38,1 ±0,76 0,38 5,56 0,05 BZE6-2RQ SPDT 15 A [9 to 13] [1.5 ±0.030] [0.015] [0.219] [0.002] BZ, A, 2,50 to 3,61 38,1 ±0,76 0,38 5,56 0,05 0.5-14 NPSM BZE6-2RQ-S SPDT 15 A [9 to 13] [1.5 ±0.030] [0.015] [0.219] [0.002] conduit thread BZ, A, 2,50 to 3,61 38,1 ±0,76 0,38 5,56 0,05 BZE6-2RQ7 #8 mounting screws SPDT 15 A [9 to 13] [1.5 ±0.030] [0.015] [0.219] [0.002] BZ, H, 2,50 to 3,61 38,1 ±0,76 0,38 5,56 0,05 Gold-plated BZE6-2RQ72 SPDT 1 A [9 to 13] [1.5 ±0.030] [0.015] [0.219] [0.002] contacts Pin Plunger BM, G, 2,50 to 3,61 38,1 ±0,76 0,38 5,56 0,05 Higher current ac BME6-2RQ SPDT 22 A [9 to 13] [1.5 ±0.030] [0.015] [0.219] [0.002] applications DT, B, 5,56 to 11,12 47,88 ±0,76 3,81 2,24 1,52 Double pole DTE6-2RQ DPDT 10 A [20 to 40] [1.885 ±0.030] [0.150] [0.088] [0.060] applications BZ, A, 2,50 to 3,61 49,61 ±1,14 0,38 3,56 0,05 BZE6-2RQ8 SPDT 15 A [9 to 13] [1.953 ±0.045] [0.015] [0.140] [0.002] BZ, A, 2,50 to 3,61 49,61 ±1,14 0,38 3,56 0,05 0.5-14 NPSM BZE6-2RQ8-S SPDT 15 A [9 to 13] [1.953 ±0.045] [0.015] [0.140] [0.002] conduit thread BZ, H, 2,50 to 3,61 49,61 ±1,14 0,38 3,56 0,05 Gold-plated BZE6-2RQ8722 Inline Roller Plunger SPDT 1 A [9 to 13] [1.953 ±0.045] [0.015] [0.140] [0.002] contacts BZ, A, 2,50 to 3,61 49,61 ±1,14 0,38 3,56 0,05 BZE6-2RQ81 SPDT 15 A [9 to 13] [1.953 ±0.045] [0.015] [0.140] [0.002] BZ, A, 2,50 to 3,61 49,61 ±1,14 0,38 3,56 0,05 0.5-14 NPSM BZE6-2RQ81-S SPDT 15 A [9 to 13] [1.953 ±0.045] [0.015] [0.140] [0.002] conduit thread BM, G, 2,50 to 3,61 49,61 ±1,14 0,38 3,56 0,05 Higher current ac BME6-2RQ81 SPDT 22 A [9 to 13] [1.953 ±0.045] [0.015] [0.140] [0.002] applications Cross Roller 6,67 to Plunger DT, B, 49,61 ±1,14 3,58 3,18 1,52 Double pole DTE6-2RQ81 13,34 applications DPDT 10 A [1.953 ±0.045] [0.141] [0.125] [0.060] [24 to 48] BZ, A, 2,78 to 5,00 61,11 Ref 4,83 5,56 0,15 BZE6-2RQ2 SPDT 15 A [10 to 18] [2.406] [0.188] [0.219] [0.006] BZ, A, 2,78 to 5,00 61,11 Ref 4,83 5,56 0,15 0.5-14 NPSM BZE6-2RQ2-S SPDT 15 A [10 to 18] [2.406] [0.188] [0.219] [0.006] conduit thread DT, B, 2,78 to 5,57 69,44 Ref 6,76 5,56 4,19 Double pole DTE6-2RQ2 Roller Lever DPDT 10 A [10 to 20] [2.734] [0.266] [0.219] [0.165] applications BZ, A, 2,22 to 5,00 5,94 5,56 0,15 BZE6-2RQ28 - SPDT 15 A [8 to 18] [0.234] [0.219] [0.006] One-way Roller Lever BZ, A, 0,56 to 1,39 18,24 21,29 5,82 BZE6-2RQ62 - SPDT 15 A [2 to 5] [0.718] [0.838] [0.229] BZ, A, 0,56 to 1,39 18,24 21,29 5,82 0.5-14 NPSM BZE6-2RQ62-S - SPDT 15 A [2 to 5] [0.718] [0.838] [0.229] conduit thread DT, B, 1,39 to 3,34 27,94 21,29 14,22 Double pole Low-force Rod DTE6-2RQ62 - Lever DPDT 10 A [5 to 12] [1,100] [0.838] [0.560] applications sensing.honeywell.com 13 Switch type, Circuitry Electrical Rating [page 6] Operate Force N [oz] Operate Point mm [in] Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. E6/V6 Series Table 7, continued. Order Guide • E6 Series Switches, Side Mount without Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Catalog Listing Comments BZ, A, 2,78 to 5,00 5,56 0,15 BZE6-2RQ4 - - SPDT 15 A [10 to 18] [0.219] [0.006] Manual Palm Button BZ, A, 1,67 to 2,64 38,1 ±0,76 0,30 4,75 Reset position: BZE6-RQX2 NA SPDT 15 A [6 to 9.5] [1.5 ±0.030] [0.012] [0.187] 46,84 [1.844] max. Pin Plunger w Manual Reset BZ, A, 1,47 to 2,64 51,18 ± 1,14 0,30 3,56 Reset position: BZE6-RQ8X2 NA SPDT 15 A [6 to 9.5] [2.015 ±0.045] [0.012] [0.140] 46,84 [1.844] max. Inline Roller Plunger w/ Manual Reset BZ, A, 1,47 to 2,64 51,18 ± 1,14 0,30 3,56 Reset position: BZE6-RQ81X2 NA SPDT 15 A [6 to 9.5] [2.015 ±0.045] [0.012] [0.140] 46,84 [1.844] max. Cross Roller Plunger w/ Manual Reset 3,34 BZ, A, 61,11 Ref 4,83 5,56 Reset position: BZE6-RQ2X2 approx. NA SPDT 15 A [2.406] [0.188] [0.219] 46,84 [1.844] max. [12 oz ] Roller Lever w/ Manual Reset sensing.honeywell.com 14 Switch type, Circuitry Electrical Rating [page 6] Operate Force N [oz] Operate Point mm [in] Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. MICRO SWITCH™ Medium-Duty Limit Switches DIMENSIONS Figure 14. Top pin plunger, side mount Figure 15. Top roller plunger, side mount Ø 8,44 mm Ø12,7 mm [0.50 in] x 23,4 mm [Ø 0.33 in] 4,6 mm [0.18 in] W [0.92 in] roller 1/2-14 NPT 49,61 mm 1/2-14 NPT 38,1 mm [1.95 in] Threads Threads [1.50 in] 25,4 mm 22,6 mm 25,4 mm 22,6 mm [1.00 in] [0.89 in] [1.00 in] [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 77,2 mm 25,4 mm 69,6 mm 25,4 mm [3.04 in] [1.00 in] [2.74 in] [1.00 in] 77,2 mm [3.04 in] Figure 17. Roller lever, adjustable, side mount Figure 16. Cross roller plunger, side mount Ø 19,0 mm [0.75 in] x Ø12,7 mm [0.50 in] x 6,4 mm [0.25 in] W 4,6 mm [0.18 in] W 39,6 mm roller roller [1.57 in] 49,61 mm 1/2-14 NPT 18,3 mm [1.95 in] [0.72 in] Threads 23,1 mm [0.91 in] 1/2-14 NPT 42,9 mm 25,4 mm Threads 22,6 mm [1.69 in] [1.00 in] [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 25,4 mm 22,6 mm 77,2 mm [3.04 in] [1.00 in] [0.89 in] 25,4 mm [1.00 in] 25,4 mm [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] Figure 18. One-way roller lever, side mount Figure 19. Rod lever, side mount 152,4 mm [6.0 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W 18,3 mm [0.72 in] roller 18,3 mm [0.72 in] 32,26 mm [1.27 in] 1/2-14 NPT 42,93 mm Threads [1.69 in] 42,93 mm 1/2-14 NPT [1.69 in] Threads 25,4 mm 22,6 mm [1.00 in] [0.89 in] 25,4 mm 22,6 mm [1.00 in] [0.89 in] 25,4 mm [1.00 in] 25,4 mm 69,6 mm [2.74 in] [1.00 in] 25,4 mm [1.00 in] 77,2 mm [3.04 in] 25,4 mm 69,6 mm [2.74 in] [1.00 in] 77,2 mm [3.04 in] sensing.honeywell.com 15 39,6 mm [1.56 in] 19.0 mm [0.75 in] 19.0 mm 19.0 mm [0.75 in] [0.75 in] 19.0 mm 19.0 mm 19.0 mm [0.75 in] [0.75 in] [0.75 in] E6/V6 Series Figure 20. Manual palm button, side mount Figure 21. Top pin plunger, reset, side mount Ø 8,44 mm [Ø 0.33 in] 38,1 mm [1.50 in] 18,3 mm [0.72 in] 1/2-14 NPT 31,75 mm Threads [1.25 in] 1/2-14 NPT 42,93 mm 22,6 mm Threads [1.69 in] [0.89 in] 25,4 mm 22,6 mm [1.00 in] 25,4 mm 25,4 mm [0.89 in] [1.00 in] [1.00 in] 25,4 mm [1.00 in] 25,4 mm 69,6 mm [2.74 in] 69,6 mm [2.74 in] [1.00 in] 77,2 mm [3.04 in] 77,2 mm [3.04 in] Figure 22. Roller plunger, reset, side mount Figure 23. Cross roller plunger, reset, side mount Ø12,7 mm [0.50 in] x 4,6 mm [0.18 in] W roller 1/2-14 NPT 49,61 mm 1/2-14 NPT Threads [1.95 in] Threads 22,6 mm 22,6 mm [0.89 in] [0.89 in] 25,4 mm 25,4 mm 25,4 mm 25,4 mm [1.00 in] [1.00 in] [1.00 in] [1.00 in] 69,6 mm [2.74 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 77,2 mm [3.04 in] Figure 24. Roller lever, reset, side mount Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W 39,6 mm roller [1.57 in] 18,3 mm [0.72 in] 23,1 mm [0.91 in] 1/2-14 NPT 42,9 mm Threads [1.69 in] 22,6 mm [0.89 in] 25,4 mm 25,4 mm [1.00 in] [1.00 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] sensing.honeywell.com 16 36,58 mm [1.44 in] 46,74 mm [1.84 in] 51,31 mm [2.02 in] 46,74 mm [1.84 in] 25,4 mm 25,4 mm 19.0 mm [1.00 in] [1.00 in] 19.0 mm [0.75 in] [0.75 in] 19.0 mm [0.75 in] 46,74 mm [1.84 in] 38,1 mm [1.50 in] 46,74 mm [1.84 in] 25,4 mm 25,4 mm 19.0 mm 19.0 mm [1.00 in] [1.00 in] [0.75 in] [0.75 in] MICRO SWITCH™ Medium-Duty Limit Switches Table 8. Order Guide • V6 Series Switches, Flange Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Catalog Listing Comments BZ, A, 2,50 to 6,67 69,09 ±1,52 1,98 5,56 0,05 BZV6-2RN SPDT 15 A [9 to 24] [2.720 ±0.060] [0.078] [0.219] [0.002] BZ, A, 2,50 to 6,67 69,09 ±1,52 1,98 5,56 0,05 0.5-14 NPSM BZV6-2RN-S SPDT 15 A [9 to 24] [2.720 ±0.060] [0.078] [0.219] [0.002] conduit thread BZ, A, 2,50 to 6,67 69,09 ±1,52 1,98 5,56 0,05 Low temperature BZV6-2RN34 SPDT 15 A [9 to 24] [2.720 ±0.060] [0.078] [0.219] [0.002] -40 °C [-40 °F] Pin plunger DT, B, 7,23 to 16,4 71,42 ±0,76 2,79 3,18 1,52 Double pole DTV6-2RN DPDT 10 A [26 to 59] [2.812 ±0.030] [0.110] [0.125] [0.060] applications BZ, A, 2,50 to 6,67 82,09 ±1,14 1,98 5,56 0,05 BZV6-2RN80 SPDT 15 A [9 to24] [3.232 ±0.045] [0.078] [0.219] [0.002] Inline Roller Plunger BZ, A, 2,50 to 6,67 82,09 ±1,14 1,98 5,56 0,05 BZV6-2RN81 SPDT 15 A [9 to24] [3.232 ±0.045] [0.078] [0.219] [0.002] Cross Roller Plunger BZ, A, 2,78 to 5,57 96,82 Ref 4,83 5,56 0,15 BZV6-2RN2 SPDT 15 A [10 to 20] [3.812] [0.188] [0.219] [0.006] DT, B, 2,78 to 8,35 94,84 Ref 6,76 5,56 4,19 Double pole DTV6-2RN2 DPDT 10 A [10 to 30] [3.734] [0.266] [0.219] [0.165] applications Roller Lever BZ, A, 2,22 to 5,56 5,94 5,56 0,15 BZV6-2RN28 - SPDT 15 A [8 to 20] [0.234] [0.219] [0.006] One-way Roller Lever BZ, A, 0,83 to 1,95 18,24 21,29 5,82 BZV6-2RN62 - SPDT 15 A [3 to 7] [0.718] [0.838] [0.229] Low-force Rod Lever sensing.honeywell.com 17 Switch type, Circuitry Electrical Rating [page 6] Operate Force N [oz] Operate Point mm [in] Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. E6/V6 Series Table 8, continued. Order Guide • V6 Series Switches, Flange Mount with Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Catalog Listing Comments BZ, A, 1,95 N. max. BZV6-2RN18 - 15° 20° Ref - SPDT 15 A [7.0 oz max.] Coil-spring Wobble BZ, A, 2,78 to 5,57 105,56 Ref. 4,83 5,56 0,15 BZV6-2RN4 SPDT 15 A [10 to 20] [4.156] [0.188] [0.219] [0.006] Manual Palm Button BZ, A, 1,67 to 5,56 69,09 ±1,52 1,98 4,78 Reset position: BZV6-RNX1 NA SPDT 15 A [6 to 20] [2.720 ±0.060] [0.078] [0.188] 26,97 [1.062] max. Pin Plunger w Manual Reset sensing.honeywell.com 18 Switch type, Circuitry Electrical Rating [page 6] Operate Force N [oz] Operate Point mm [in] Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. MICRO SWITCH™ Medium-Duty Limit Switches DIMENSIONS Figure 25. Top pin plunger, flange mount with boot seal Figure 26. Top roller plunger, flange mount with boot seal Ø12,7 mm [0.50 in] x 2,0 mm Ø 8,44 mm 4,6 mm [0.18 in] W [Ø 0.33 in] [0.08 in] roller 82,04 mm 1/2-14 NPT [3.23 in] 1/2-14 NPT 69,1 mm Threads Threads [2.72 in] 2X Ø 4,37 mm 2X Ø 4,37 mm [Ø 0.172 in] 44,4 mm [Ø 0.172 in] [1.75 in] 44,4 mm 22,6 mm [1.75 in] 22,6 mm [0.89 in] [0.89 in] 25,4 mm 10,7 mm [1.00 in] [0.42 in] 10,7 mm 25,4 mm 3,3 mm 69,6 mm [2.74 in] [0.42 in] 3,3 mm [1.00 in] 41,4 mm [1.63 in] [0.13 in] 69,6 mm [0.13 in] 41,4 mm [1.63 in] [2.74 in] 54,1 mm [2.13 in] 54,1 mm [2.13 in] Figure 27. Cross roller plunger, flange mount with boot seal Figure 28. Roller lever adjustable, flange mount with boot seal Ø12,7 mm [0.50 in] x Ø 19,0 mm [0.75 in] x 4,6 mm [0.18 in] W 6,4 mm [0.25 in] W roller 39,6 mm roller [1.57 in] 56,64 mm 18,3 mm [2.23 in] [0.72 in] 1/2-14 NPT 23,1 mm Threads [0.91 in] 2X Ø 4,37 mm [Ø 0.172 in] 53,1 mm 1/2-14 NPT 25,4 mm 22,6 mm [2.09 in] Threads [1.00 in] [0.89 in] 2X Ø 4,37 mm 25,4 mm 10,7 mm [Ø 0.172 in] [1.00 in] [0.42 in] 3,3 mm 69,6 mm [2.74 in] 41,4 mm [1.63 in] [0.13 in] 77,2 mm [3.04 in] 25,4 mm 22,6 mm [1.00 in] [0.89 in] 54,1 mm [2.13 in] 25,4 mm 10,7 mm [1.00 in] [0.42 in] 3,3 mm 69,6 mm [2.74 in] 41,4 mm [1.63 in] [0.13 in] 77,2 mm [3.04 in] 54,1 mm [2.13 in] Figure 30. Rod lever, flange mount with boot seal Figure 29. One-way roller lever, flange mount with boot seal 152,4 mm [6.0 in] Ø 19,0 mm [0.75 in] x 6,4 mm [0.25 in] W 18,3 mm [0.72 in] roller 18,3 mm [0.72 in] 32,26 mm [1.27 in] 53,1 mm 1/2-14 NPT [2.09 in] 53,1 mm Threads 1/2-14 NPT [2.09 in] Threads 2X Ø 4,37 mm 2X Ø 4,37 mm [Ø 0.172 in] [Ø 0.172 in] 25,4 mm 22,6 mm 25,4 mm [1.00 in] [0.89 in] 22,6 mm [1.00 in] [0.89 in] 10,7 mm 25,4 mm [0.42 in] [1.00 in] 25,4 mm 10,7 mm 3,3 mm [1.00 in] [0.42 in] 69,6 mm [2.74 in] 41,4 mm [1.63 in] 3,3 mm [0.13 in] 69,6 mm [2.74 in] 77,2 mm [3.04 in] 41,4 mm [1.63 in] [0.13 in] 77,2 mm [3.04 in] 54,1 mm [2.13 in] 54,1 mm [2.13 in] sensing.honeywell.com 19 39,6 mm [1.56 in] 19.0 mm 19.0 mm [0.75 in] [0.75 in] 19.0 mm 19.0 mm [0.75 in] [0.75 in] E6/V6 Series Figure 31. Manual palm button, flange mount with boot seal Figure 32. Coil wobble, flange mount with boot seal Ø 7,11 mm [Ø 0.28 in] 38,1 mm 18,3 mm [1.50 in] [0.72 in] 108,97 mm 31,75 mm [4.29 in] [1.25 in] 149,35 mm [5.88 in] 1/2-14 NPT 53,1 mm 1/2-14 NPT [2.09 in] Threads Threads 2X Ø 4,37 mm 2X Ø 4,37 mm [Ø 0.172 in] [Ø 0.172 in] 25,4 mm 25,4 mm 22,6 mm 22,6 mm [1.00 in] [1.00 in] [0.89 in] [0.89 in] 25,4 mm 10,7 mm 10,7 mm 25,4 mm [1.00 in] [0.42 in] [1.00 in] [0.42 in] 3,3 mm 3,3 mm 69,6 mm [2.74 in] 69,6 mm [2.74 in] 41,4 mm [1.63 in] 41,4 mm [1.63 in] [0.13 in] [0.13 in] 77,2 mm [3.04 in] 77,2 mm [3.04 in] 54,1 mm [2.13 in] 54,1 mm [2.13 in] Figure 33. Top pin plunger, reset, flange mount with boot seal Ø 8,44 mm [Ø 0.33 in] 10,7 mm [0.42 in] 1/2-14 NPT Threads 2X Ø 4,37 mm [Ø 0.172 in] 22,6 mm [0.89 in] 3,3 mm [0.13 in] 25,4 mm 25,4 mm [1.00 in] [1.00 in] 69,6 mm [2.74 in] 41,4 mm [1.63 in] 77,2 mm [3.04 in] 54,1 mm [2.13 in] sensing.honeywell.com 20 36,58 mm [1.44 in] 53,1 mm [2.09 in] 43,69 mm [1.72 in] 25,4 mm [1.00 in] 19.0 mm 19.0 mm [0.75 in] [0.75 in] 19.0 mm [0.75 in] MICRO SWITCH™ Medium-Duty Limit Switches Table 9. Order Guide • V6 Series Switches, Flange Mount without Boot Seal For catalog listings not shown, please contact your Honeywell distributor or representative. Catalog Listing Comments BZ, A, 2,50 to 3,61 63,50 ±1,14 0,38 5,56 0,05 BZV6-2RQ SPDT 15 A [9 to 13] [2.50 ±0.045] [0.015] [0.219] [0.002] Pin plunger BZ, A, 2,50 to 3,61 75,01 ±1,52 0,38 3,56 0,05 BZV6-2RQ8 SPDT 15 A [9 to 13] [2.953 ±0.060] [0.015] [0.140] [0.002] Inline Roller Plunger BZ, A, 2,50 to 3,61 75,01 ±1,52 0,38 3,56 0,05 BZV6-2RQ81 SPDT 15 A [9 to 13] [2.953 ±0.060] [0.015] [0.140] [0.002] Cross Roller Plunger BZ, A, 2,78 to 5,00 86,51 Ref 4,83 5,56 0,15 BZV6-2RQ2 SPDT 15 A [10 to 18] [3.406] [0.188] [0.219] [0.006] Roller Lever BZ, A, 0,56 to 1,39 18,24 21,29 5,82 BZV6-2RQ62 - SPDT 15 A [2 to 5] [0.718] [0.838] [0.229] Low-force Rod Lever sensing.honeywell.com 21 Switch type, Circuitry Electrical Rating [page 6] Operate Force N [oz] Operate Point mm [in] Pretravel mm [in] max. Over Travel mm [in] min. Differential Travel mm [in] max. E6/V6 Series DIMENSIONS Figure 34. Top pin plunger, flange mount Figure 35. Top roller plunger, flange mount Ø12,7 mm [0.50 in] x Ø 8,44 mm 4,6 mm [0.18 in] W [Ø 0.33 in] roller 74,93 mm 1/2-14 NPT 1/2-14 NPT [2.95 in] Threads 63,5 mm Threads [2.50 in] 2X Ø 4,37 mm 2X Ø 4,37 mm [Ø 0.172 in] 44,4 mm [Ø 0.172 in] 44,4 mm [1.75 in] [1.75 in] 22,6 mm 22,6 mm [0.89 in] [0.89 in] 25,4 mm 10,7 mm 25,4 mm [1.00 in] 10,7 mm [0.42 in] [1.00 in] 3,3 mm [0.42 in] 69,6 mm [2.74 in] 3,3 mm 41,4 mm [1.63 in] 69,6 mm [0.13 in] [0.13 in] 41,4 mm [1.63 in] [2.74 in] 54,1 mm [2.13 in] 54,1 mm [2.13 in] Figure 36. Cross roller plunger, flange mount Figure 37. Roller lever adjustable, flange mount Ø 19,0 mm [0.75 in] x Ø12,7 mm [0.50 in] x 6,4 mm [0.25 in] W 4,6 mm [0.18 in] W 39,6 mm roller roller [1.57 in] 74,9 mm 1/2-14 NPT 18,3 mm [2.95 in] Threads [0.72 in] 23,1 mm 2X Ø 4,37 mm 44,4 mm [0.91 in] [Ø 0.172 in] [1.75 in] 22,6 mm 1/2-14 NPT 42,9 mm [0.89 in] Threads [1.69 in] 25,4 mm 10,7 mm 2X Ø 4,37 mm [1.00 in] [0.42 in] [Ø 0.172 in] 3,3 mm 69,6 mm [2.74 in] 41,4 mm [1.63 in] [0.13 in] 77,2 mm [3.04 in] 25,4 mm 22,6 mm 54,1 mm [2.13 in] [1.00 in] [0.89 in] 25,4 mm 10,7 mm [1.00 in] [0.42 in] 3,3 mm 69,6 mm [2.74 in] Figure 38. Rod lever, flange mount 41,4 mm [1.63 in] [0.13 in] 77,2 mm [3.04 in] 152,4 mm [6.0 in] 54,1 mm [2.13 in] 18,3 mm [0.72 in] 1/2-14 NPT 42,93 mm Threads [1.69 in] 2X Ø 4,37 mm [Ø 0.172 in] 25,4 mm 22,6 mm [1.00 in] [0.89 in] 25,4 mm 10,7 mm [0.42 in] [1.00 in] 3,3 mm 69,6 mm [2.74 in] 41,4 mm [1.63 in] [0.13 in] 77,2 mm [3.04 in] 54,1 mm [2.13 in] sensing.honeywell.com 22 19.0 mm [0.75 in] 19.0 mm [0.75 in] MICRO SWITCH™ Medium-Duty Limit Switches E6/V6 REPLACEMENT PARTS The metal bottom cover includes the insulator seal and two cover screws The plunger seal boot includes the plunger seal and retaining hardware The hardware packet includes mounting hardware and seal boot as noted in the tables Table 10. Actuator with Boot Seal Replacement Parts Plunger Seal Internal Basic Cat. Listing Bottom Cover Hardware Packet Actuator 1 Boot Switch BZE6-2RN 3PA13-E6 10PA2 1PA2* BZ-2RQ77** Integral to internal basic switch BZV6-2RN 3PA14-V6 10PA2 1PA2* BZ-2RQ77** Integral to internal basic switch 2 BZE6-2RN7 3PA13-E6 10PA2 1PA46* BZ-2RN730** Integral to internal basic switch BZE6-2RN72 3PA13-E6 10PA2 1PA2* BZ-2RQ7722** Integral to internal basic switch BZE6-2RN80 3PA13-E6 10PA2 1PA47 BZ-2RN784 Integral to internal basic switch BZE6-2RN2 3PA13-E6 10PA2 1PA13* BZ-2RN702** 6PA2* BZV6-2RN2 3PA14-V6 10PA2 1PA13* BZ-2RN702** 6PA2* 3 BZE6-2RN18 3PA13-E6 10PA2 - BZ-2R-A2 6PA195 3 BZV6-2RN18 3PA14-V6 10PA2 - BZ-2R-A2 6PA195 DTE6-2RN 3PA13-E6 10PA2 1PA2 DT-2R3-A7 8PA14 DTV6-2RN 3PA14-V6 10PA2 1PA2 DT-2R3-A7 8PA14 DTE6-2RN2 3PA13-E6 10PA2 - DT-2R3-A7 6PA2* DTV6-2RN2 3PA14-V6 10PA2 - DT-2R3-A7 6PA2* *Includes plunger seal boot **Includes hardware packet 1. To order replacement low temperature plunger boot seal (switch code 34), specify 10PA1 2. 1PA46 hardware packet cannot be ordered separately. When BZ-2RN730 internal basic switch is ordered, the 1PA46 hardware packet is included with internal basic switch. 3. To order replacement wobble actuator including internal threaded bushing, specify 6PA188-F Table 11. Actuator without Boot Seal Replacement Parts Cat. Listing Bottom Cover Hardware Packet Internal Basic Switch Actuator BZE6-2RQ 3PA13-E6 1PA1 BZ-2RQ66 Integral to internal basic switch BZV6-2RQ 3PA14-V6 1PA1 BZ-2RQ66 Integral to internal basic switch BZE6-2RQ8 3PA13-E6 1PA19 BZ-2RQ784** Integral to internal basic switch BZV6-2RQ8 3PA14-V6 1PA19 BZ-2RQ784** Integral to internal basic switch BZE6-2RQ81 3PA13-E6 1PA19 BZ-2RQ785** Integral to internal basic switch BZV6-2RQ81 3PA14-V6 1PA19 BZ-2RQ785** Integral to internal basic switch BZE6-2RQ2 3PA13-E6 1PA3 BZ-2RQ68** 6PA1 BZV6-2RQ2 3PA14-V6 1PA3 BZ-2RQ68** 6PA1 **Includes hardware packet sensing.honeywell.com 23 E6/V6 Series This Honeywell datasheet supports the following MICRO SWITCH™ E6/V6 Series Limit Switch Listings BZE6-2RN4 BZE6-2RN72-S BZE6-3YNP BZV6-2RQ2 BZE6-2RN7 BZE6-2RN7-S BZE6-3YNT BZV6-2RQ39 BZE6-2RN80 BZE6-2RN8 BZE6-3YQ9 BZV6-2RQ62 BZE6-2RQ2 BZE6-2RN8034 BZE6-3YQT BZV6-2RQ8 BZE6-RN80X2 BZE6-2RN81 BZE6-7RN BZV6-2RQ81 BZE6-2AQ BZE6-2RN-C BZE6-7RN18 BZV6-2RQ9 BZE6-2AQ8T BZE6-2RN-F1 BZE6-7RN1812 BZV6-7RN BZE6-2GN BZE6-2RN-F3 BZE6-7RN51 BZV6-7RN2T BZE6-2RN BZE6-2RN-F6 BZE6-7RN8051 BZV6-RNX1 BZE6-2RN18 BZE6-2RN-FR BZE6-7RNT 10PA1 BZE6-2RN1809-5 BZE6-2RN-M BZE6-7RQ8 10PA2 BZE6-2RN1810 BZE6-2RN-R BZE6-7RQ9 19PA22-E6 BZE6-2RN1812 BZE6-2RN-S BZE6-7RQ9T 3PA13-E6 BZE6-2RN183 BZE6-2RQ BZE6-RN 3PA14-V6 BZE6-2RN185 BZE6-2RQ125 BZE6-RN18X1 6PA140-E6 BZE6-2RN185-WP BZE6-2RQ136 BZE6-RN18X2 6PA147-E6 BZE6-2RN187 BZE6-2RQ165 BZE6-RN18X3 6PA148-E6 BZE6-2RN1872 BZE6-2RQ168 BZE6-RN2X1 6PA187-E6 BZE6-2RN18721 BZE6-2RQ219 BZE6-RNX1 BME6-2RN BZE6-2RN18-C3 BZE6-2RQ241 BZE6-RNX12 BME6-2RN2 BZE6-2RN19 BZE6-2RQ28 BZE6-RNX17 BME6-2RN373 BZE6-2RN191-S BZE6-2RQ2-S BZE6-RQ BME6-2RQ BZE6-2RN193 BZE6-2RQ4 BZE6-RQ2 BME6-2RQ171 BZE6-2RN196-F5 BZE6-2RQ5 BZE6-RQ2X2 BME6-2RQ173 BZE6-2RN2 BZE6-2RQ62 BZE6-RQ71 BME6-2RQ273 BZE6-2RN221 BZE6-2RQ62-S BZE6-RQ81X2 BME6-2RQ81 BZE6-2RN224 BZE6-2RQ7 BZE6-RQ8X2 DTE6-2RN BZE6-2RN234 BZE6-2RQ72 BZE6-RQ8X4 DTE6-2RN2 BZE6-2RN272 BZE6-2RQ8 BZE6-RQ9 DTE6-2RN28 BZE6-2RN28 BZE6-2RQ81 BZE6-RQX2 DTE6-2RN281 BZE6-2RN281 BZE6-2RQ814 BZV6-2RN DTE6-2RN4 BZE6-2RN28-S BZE6-2RQ81-S BZV6-2RN18 DTE6-2RN80 BZE6-2RN2-F3 BZE6-2RQ841-BP BZV6-2RN2 DTE6-2RN8034-M BZE6-2RN2-F6 BZE6-2RQ8722 BZV6-2RN28 DTE6-2RQ BZE6-2RN2-S BZE6-2RQ8-S BZV6-2RN34 DTE6-2RQ2 BZE6-2RN2-TW BZE6-2RQ9 BZV6-2RN4 DTE6-2RQ62 BZE6-2RN34 BZE6-2RQ9-S BZV6-2RN62 DTE6-2RQ81 BZE6-2RN37 BZE6-2RQ-S BZV6-2RN80 DTE6-2RQ9 BZE6-2RN39 BZE6-3RN BZV6-2RN81 DTV6-2RN BZE6-2RN5 BZE6-3RN18150-C BZV6-2RN-C DTV6-2RN2 BZE6-2RN51 BZE6-3RN2153 BZV6-2RN-S DTV6-2RN4 BZE6-2RN62 BZE6-3YN2 BZV6-2RQ HSE6-3RNT2 BZE6-2RN72 sensing.honeywell.com 24 MICRO SWITCH™ Medium-Duty Limit Switches ADDITIONAL INFORMATION WARNING The following associated literature is available on the Honeywell web PERSONAL INJURY site at sensing.honeywell.com: DO NOT USE these products as safety or emergency stop • Product installation instructions devices or in any other application where failure of the • Product range guide product could result in personal injury. • Product nomenclature tree Failure to comply with these instructions could result in • Product application-specific information death or serious injury. – Limit and enclosed switch reference standards – Application note: Machine tool application guide WARNING – Application note: Industrial machinery switch guide MISUSE OF DOCUMENTATION • The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. • Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particu- lar purpose. In no event shall Honeywell be liable for conse- quential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. sensing.honeywell.com 25 Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell’s sensing and control products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North 002383-2-EN IL50 GLO Golden Valley, MN 55422 December 2014 honeywell.com Copyright © 2014 Honeywell International Inc. All rights reserved.
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the BME6-2RN?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers







What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods