Electronics Finder Manufacturers H HONEYWELL PX3AN2BS100PAAAX
About product Specifications Datasheet FAQ

HONEYWELL PX3AN2BS100PAAAX

Image of HONEYWELL PX3AN2BS100PAAAX

Description

Pressure Sensor 0.5V to 4.5V 0psi to 100psi Absolute

Part Number

PX3AN2BS100PAAAX

Price

Request Quote

Manufacturer

HONEYWELL

Lead Time

Request Quote

Category

Sensors and Transducers »  Industrial Pressure Sensor

Specifications

Manufacturer

Honeywell

Manufacturers Part #

PX3AN2BS100PAAAX

Sub-Category

Industrial Pressure Sensors

Brand

Micro Switch

Factory Pack Quantity

1

Datasheet

pdf file

honeywell-sensing-px3-series-datasheet-32313757-a-en.pdf

2294 KiB

Extracted Text

Heavy Duty Pressure Transducers 32313757 PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi Issue E Datasheet Figure 2. PX3 Series External Freeze/Thaw Resistance (Shown with mating connector, see Figure 5.) • Reduced current consumption: Helps to reduce energy costs, and enhances product life if used in battery driven systems. • Media compatibility: Common HFC (hydrofluorocarbon) refrigerants (R410A and R134A), next generation low global warming potential (GWP) refrigerants (R448A/ ® Solstice N40, R32 and R1234ZE), engine oil, petroleum- based hydraulic fluids, brake fluids (DOT3), and dry air. For ammonia and other corrosive media, see Honeywell’s SPT Series. DIFFERENTIATION • Optional diagnostics mode: Beneficial in applications where the sensor functionality and the need to know internal or DESCRIPTION external failure modes is critical. Honeywell’s PX3 Series Heavy Duty Pressure Transducers • Great customer value: Multiple configuration possibilities use piezoresistive sensing technology with ASIC (Application provide flexibility of use in the application with no upfront Specific Integrated Circuit) signal conditioning in a brass NRE or tooling charges. housing and Metri-Pack 150, DIN, or cable harness electrical • Durable: Provides the tough environmental specifications connections. The PX3 Series is calibrated and temperature needed, including insulation resistance and dielectric compensated from -40°C to 125°C [-40°F to 257°F]. strength, external freeze-thaw resistance (see Figure 2), and EMC performance. VALUE TO CUSTOMERS • 4 mA to 20 mA output is temperature compensated up to 125°C. • Total Error Band (TEB) ±1.0 %FSS from -20°C to 85°C: FEATURES Provides indication of the sensor’s true measurement • Pressure range: 1 bar to 50 bar | 15 psi to 700 psi (absolute performance over a specified temperature range; small and sealed gage) error promotes system uptime and efficiency. (See Figure 1.) • Ratiometric output: 0.5 Vdc to 4.5 Vdc or 0.33 Vdc to 2.97 Vdc • 4 mA to 20 mA output supports transmission of output Figure 1. TEB Definition and Temperature Performance signals over longer distances • Calibrated and temperature compensated Sources of Error • Total Error Band: ±1.0 %FSS from -20°C to 85°C [-4°F to 185°F] Offset • External freeze/thaw resistance: 6 cycles from -30°C to Full Scale Span 50°C [-22°F to 122°F] Pressure Non-Linearity Total Accuracy • Insulation resistance: >100 MOhm, 1500 Vdc (in dry, non- Pressure Hysteresis Error BFSL ionized air) Pressure Non-Repeatability Band • Dielectric strength: AC1500V, 1 min. or AC1800V, 1 s (in dry, non- Thermal Effect on Offset ionized air) Thermal Effect on Span • Current consumption: 3.5 mA max. Thermal Hysteresis • EMC (radiated immunity): 200 V/m (ratiometric voltage 3 output), 140 V/m (current output) per ISO 11452-2 Total Error Band 2 • Ingress protection IP67 (Metri-Pack connector), IP69K (cable harness), IP65 (DIN connector) 1 • RoHS, REACH, and CE compliant 0 • Six industry-standard pressure port types, including a tube port -1 which provides for hermetically-sealed process connection -2 POTENTIAL APPLICATIONS -3 • Industrial: Refrigerant pressure monitoring in HVAC/R -40°C -20°C 0°C 85°C 125°C [-40°F] [-4°F] [32°F] [185°F] [257°F] systems; dry air system pressure, process controls and Temperature (°C [°F]) automation • Transportation: Dry air system monitoring; hydraulic, brake, and engine oil fluid pressure monitoring; air brake pressure • Higher insulation resistance and dielectric strength: monitoring Protects the user and sensor in high over-voltage situations, and ensures that the device is compliant with The PX3 Series is not recommended for use with media industry standards. involving water, saturated air such as steam and vapor, and • Higher EMC performance: Operates more reliably in the ammonia. presence of electro-magnetic fields, such as near wireless PORTFOLIO signals, RF communication, and electrical devices. Honeywell’s PX3 Series joins the PX2 Series, MLH Series, and • Higher external freeze/thaw resistance: Survives exposure to SPT Series heavy duty pressure transducers. frost, commonly found in refrigeration systems. (See Figure 2.) Sensing and Internet of Things Total Error Band (%FSS) Heavy Duty Pressure Transducers PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi Table 1. Electrical Specifications Characteristic Parameter Supply voltage: ratiometric voltage output: 5 Vdc 5 Vdc ±0.25 Vdc 3.3 Vdc 3 Vdc ±0.25 Vdc current output: -40°C to 100°C 8 Vdc to 30 Vdc >100°C to 125°C 8 Vdc to 25 Vdc Over voltage and reverse voltage: ratiometric voltage output ±16 Vdc current output ±35 Vdc Current consumption: 5 Vdc supply 3.0 mA max. 3.3 Vdc supply 1.6 mA to 2.1 mA Short circuit protection yes Nominal output transfer function: 5 Vdc supply 0.5 Vdc to 4.5 Vdc (ratiometric to supply) 3.3 Vdc supply 0.33 Vdc to 2.97 Vdc (ratiometric to supply) 8 Vdc to 30 Vdc supply 4 mA to 20 mA Table 2. Performance Specifications (At 25°C [77°F] and under unless otherwise noted.) Characteristic Parameter 1 Operating temperature range -40°C to 125°C [-40°F to 257°F] 1 Storage temperature range -40°C to 125°C [-40°F to 257°F] Compensated temperature range -40°C to 125°C [-40°F to 257°F] 2 Total Error Band : -20°C to 85°C [-4°F to 185°F] ±1.0 %FSS <-20°C, >85°C [<-4°F, >185°F] ±2.0 %FSS 3 Accuracy BFSL ±0.25 %FSS Response time <2 ms (10% to 90% step change in pressure) 4 Turn on time <7 ms 5 EMC rating : surge immunity (all leads) ±1000 V line to ground per IEC 61000-4-5 electrostatic discharge ±4 kV contact, ±8 kV air per IEC 61000-4-2 radiated immunity 10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3 fast transient burst ±1 kV per IEC 61000-4-4 immunity to conducted disturbances 3 V per IEC 61000-4-6 radiated emissions 40 dBμV (30 MHz to 230 MHz), 47 dBμV (230 MHz to 1000 MHz) per CISPR 11 radiated immunity: ratiometric (voltage) output 200 V/m per ISO 11452-2 4 mA to 20 mA (current) output 140 V/m per ISO 11452-2 6 Insulation resistance : ratiometric voltage output >100 MOhm at 1500 Vdc current output >100 MOhm at 1000 Vdc Dielectric strength <1 mA at 1500 Vac (1 min) or 1800 Vac (1 s) 6 Load resistance : ratiometric voltage output >5 kOhm current output (V - 8) x 50 Ohm in Life >10 million full scale pressure cycles over the calibrated pressure range 1 Dependent on seal material. See Figure 5. 2 Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, pressure non-repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis. 3 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25°C [77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and pressure non-repeatability. 4 Turn on time: Duration from power applied until first valid output for voltage output. Typical value for 4 mA to 20 mA output. 5 Tested using 1,5 m [59.1 in] long cable. 6 Tested in dry, non-ionized air. 2 Sensing and Internet of Things Heavy Duty Pressure Transducers PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi Table 3. Pressure Reference Definitions Pressure Reference Definition Output is calibrated to be proportional to the difference between applied pressure and a fixed reference to Absolute perfect vacuum (absolute zero pressure). Sensor construction is identical to the absolute version with a built in reference at zero pressure in order to minimize measurement error over temperature. The output is calibrated to be proportional to the difference 1 Sealed gage between applied pressure and a reference of 1 standard atmosphere (1.013 barA | 14.7 psiA). Example: 100 psi sealed gage has a calibrated pressure range from 14.7 psi absolute to 114.7 psi absolute. (See Figure 3.) 1 Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi. Diagnostics Mode (For Ratiometric Voltage Output Only) Figure 3. Ratiometric Output Option AA for 100 psi, Absolute vs Sealed Gage The PX3 Series diagnostics mode allows the device to indicate when internal or external faults occur. If an internal 5 fault occurs, the output will rail to the preset lower or upper 4.5 limit values shown in Figure 4 and Table 5. 4 External faults will result in the sensor’s output exceeding 3.5 those preset limits (lower or upper). (For example, if the 3 external sensor ground (signal) were lost, the sensor output would exceed the upper rail of 97.5%.) 2.5 100 psi absolute 2 Figure 4. Analog Output with Diagnostics 100 psi sealed gage 1.5 100 1 Upper Rail (97.5%) 90 0.5 80 0 70 0 20 40 60 80 100 120 140 60 14.7 114.7 Pressure (psi Absolute) 50 40 30 Table 4. Pressure Ratings 20 bar psi 10 Operating Over- Burst Operating Over- Burst Lower Rail (2.5%) 0 10 20 30 40 50 60 70 80 90 100 Pressure pressure Pressure Pressure pressure Pressure Pressure (psi) 1 5 8 15 70 115 1.6 5 8 30 150 250 Table 5. Output Transfer Function Codes 2 10 17 50 250 400 Fault Condition Analog Diagnostic Rail 2.5 10 17 100 450 750 EEPROM Corrupt below lower rail 4 17 27 150 450 750 6 31 51 174 450 750 Sensor Bridge Open above upper rail (any element) 8 31 51 200 450 1150 10 31 51 250 450 1150 Sensor Bridge Short above upper rail (any element) 12 31 51 300 1000 1500 16 32 80 500 1000 1500 Low supply voltage below lower rail 20 69 103 600 1000 1500 Loss of ground connection above upper rail 25 69 103 667 1000 1500 30 69 103 700 1000 1500 35 69 103 - - - 40 69 103 - - - 46 69 103 - - - 50 69 103 - - - Sensing and Internet of Things 3 Output (V) Output (%Vsupply) Heavy Duty Pressure Transducers PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi Table 6. Environmental and Mechanical Specifications Characteristic Parameter Shock: threaded ports 100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C [77°F]) tube port 100 G per MIL-STD-202F, Method 213B, and Condition C Vibration: threaded ports 20 G sweep, 10 Hz to 2000 Hz (at 25°C [77°F]) tube port 10 Hz to 55 Hz, 2 mm displacement, tested as per IEC 60068-2-6; Test FC. (at 25°C [77°F]) Ingress protection: Metri-Pack 150 electrical connector IP67 DIN electrical connector IP65 Cable harness electrical connector IP65, IP67, IP69K Ambient humidity 0 %RH to 95 %RH, non-condensing External freeze/thaw resistance >6 cycles from -30°C to 50°C [-22°F to 122°F] Wetted materials: threaded ports brass C36000; lead (Pb) content: 3.7% max. external seals for ports nitrile tube port copper UNS C12200; lead (Pb) free braze filler silver and copper alloy internal O-ring media seal seal material based on application (see seal material media compatibility options below) sensing element and substrate alumina, glass, silicon adhesives epoxy 1 Internal O-ring material media compatibility : HNBR (option H) refrigerants, engine oil, petroleum-based hydraulic fluid silicone (option S) dry air Electrical connector material PBT 30% GF 1 Honeywell can assist with selecting suitable O-ring seal material for the media based on the seal manufacturer’s recommendation. The customer should test the compatibility with the media to ensure that it is correct for the application. CAUTION PRODUCT DAMAGE TO TUBE PRESSURE PORT TYPE DURING BRAZING Ensure that the temperature of the brass port and plastic connector is maintained below 125°C during flame brazing. Exposure to temperatures higher than 125°C can cause permanent product damage and can compromise ingress protection leading to short circuits. Failure to comply with these instructions may result in product damage. CAUTION PRODUCT DAMAGE DUE TO MECHANICAL ISSUES • Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating materials and thread sealants can result in significantly different torque values from one application to the next.) • When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling. Ensure the sealant is rated for the application. • Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers. • Always hand-start transducers into the hole to prevent cross threading and damage. • Ensure that torque is not applied to the electrical connector. • Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged seals can compromise ingress protection, leading to short circuits. Failure to comply with these instructions may result in product damage. CAUTION PRODUCT DAMAGE DUE TO PARTICULATES AND SATURATED AIR Ensure that filters and dehumidifiers are used upstream of the transducers to keep media flow free of large particulates and condensed moisture. PX3 Series transducers are dead-end devices. Particulate accumulation may clog the port or damage the diaphragm. Condensing moisture may affect sensor output and lower insulation resistance. Failure to comply with these instructions may result in product damage. CAUTION PRODUCT DAMAGE DUE TO CONDUCTIVE MEDIA Ensure sensor is not used with conductive or ionic media. These media can affect sensor output and lower insulation resistance. Failure to comply with these instructions may result in product damage. 4 Sensing and Internet of Things Heavy Duty Pressure Transducers PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi Figure 5. Nomenclature and Order Guide For example, PX3AN1BS150PAAAX defines a PX3 Series Heavy Duty Pressure Transducer, Metri-Pack 150, standard (UL V-0) electrical connector type, 1/4-18 NPT pressure port type, brass housing body, silicone: -40°C to 125°C [-40°F to 257°F] seal material and temperature range, 150 psi pressure range, absolute pressure reference, ratiometric: 0.5 Vdc to 4.5 Vdc output transfer function, no special PX3 A N1 B S 150P A AA X Special Series X Heavy Duty PX3 1 Pressure Transducer Output Transfer Function AA Ratiometric: 5.0 V, 10% to 90% Vs Electrical Connector Type 6 DA Ratiometric: 5.0 V, 10% to 90% Vs (diagnostics on) Metri-Pack 150, AC Ratiometric: 3.3 V, 10% to 90% Vs A 2 Standard (UL V-0) 6 DC Ratiometric: 3.3 V, 10% to 90% Vs (diagnostics on) DIN CH Current: 4 mA to 20 mA (Male, EN 175301-803C) C Pressure Reference 3 3 A Absolute PVC Cable XLPE Cable 7 -40°C to 105°C -40°C to 125°C Sealed gage S [-40°F to 221°F] [-40°F to 257°F] Pressure Range two or three two or three bar psi 22 AWG wires 22 AWG wires 001B 1 bar 016B 16 bar 015P 15 psi 250P 250 psi 0.5 m [1.3ft] K L 1.6B 1.6 bar 020B 20 bar 030P 30 psi 300P 300 psi 002B 2 bar 025B 25 bar 050P 50 psi 500P 500 psi 1.0 m [3.2 ft] E M 2.5B 2.5 bar 030B 30 bar 100P 100 psi 600P 600 psi 004B 4 bar 035B 35 bar 150P 150 psi 667P 667 psi 2.0 m [6.6 ft] F N 006B 6 bar 040B 40 bar 174P 174 psi 700P 700 psi 3.0 m [9.8 ft] G P 008B 8 bar 046B 46 bar 200P 200 psi 010B 10 bar 050B 50 bar 5.0 m [16.4 ft] H Q 012B 12 bar Three-wire cable is required for ratiometric Output Transfer 1, 8 Internal O-ring Material and Temperature Range Functions AA, DA, AC and DC; two-wire cable is required for HNBR (Hydrogenated Nitrile Butadiene Rubber): H Output Transfer Function CH. -30°C to 125°C [-22°F to 257°F] S Silicone: -40°C to 125°C [-40°F to 257°F] Three meter and five meter cables are only available with Output Transfer Housing Body Material three-wire two-wire Function CH. B Brass (C36000) 4 Pressure Port Type 1 Not all catalog listing combinations are shown. Custom configurations, 7/16-20 UNF such as varied cable lengths, end mating connectors, different O-ring 1/4 inch 45° Flare materials, and different pressure ranges are available. Please contact F1 Female Schrader Honeywell. (SAE J512) 2 Metri-Pack 150 mating connectors with shielded cable and three 22 AWG wires are available from Honeywell. Order part no. 3685301 for 1 m [3.2 ft] G1/4 A-G cable length and part no. 3685302 for 3 m [9.8 ft] cable length. G1 (ISO 1179-3) 3 PVC Flame Retardant (FR) type cable is FT1 rated per IEC60332-1; XLPE non-flame retardant cable is FT2 rated per IEC60332-1. G1/4 A-L 4 See Table for pressure port materials. G2 (ISO 1179-2) 5 Tube port is not available with DIN connector option. 6 See page 3 for Diagnostics Mode information. M12 x 1.5 7 M1 Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi. (ISO 6149-3) 8 See Table 6 for O-ring seal material media compatibility. 1/4-18 NPT N1 2 Mating Connector (ANSI/ASME B1.20.1) 1/8-27 NPT N2 (ANSI/ASME B1.20.1) 5 T1 Tube Sensing and Internet of Things 5 Heavy Duty Pressure Transducers PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi Figure 6. Metri-Pack Mounting Dimensions (For reference only. mm/[in].) E General product marking Pinout F1, G1, G2, M1, N1, N2 T1 Ratiometric Voltage Output Pin A Pin A Pin A = Ground Pin B = V+ Pin C = Vout Yellow lettering 22,0 Current Output [0.87] Pin A = Return Pin B = Supply Pin C = Not connected Pin C Pin C Pin B Pin B F1: 7/16-20 UNF 1/4 inch 45° Flare G1: G1/4 A-G (ISO 1179-3) G2: G1/4 A-L (ISO 1179-2) Female Schrader (SAE J512) Seal: O-ring (included) Seal: ISO 9974-2/DIN 3869 profile ring (included) Seal: 45° cone Mating geometry: ISO 1179-1 Mating geometry: ISO 1179-1 Mating geometry: SAE J512 Installation torque: 50 N m [36.9 ft-lb] Installation torque: 50 N m [36.9 ft-lb] Installation torque: 17 N m [12.5 ft-lb] Weight: 35,1 g to 40,1 g [1.2 oz to 1.4 oz] Weight: 35,1 g to 40.1 g [1.2 oz to 1.4 oz] Weight: 41 g to 46 g [1.4 oz to 1.6 oz] ø17,0 ø17,0 ø17,0 [0.67] [0.67] [0.67] ø21,6 ø21,6 ø21,6 34,9 37,4 [0.85] 35,9 [0.85] [0.85] [1.37] [1.47] [1.41] 47,1 48,9 49,6 [1.85] [1.93] [1.95] 12,9 15,4 13,9 [0.51] [0.61] [0.55] 14,0 Profile ring 12,2 11,2 O-ring [0.55] [0.48] [0.44] 7/16-20 UNF 1/4 in 45° Flare Female G1/4 A-G (ISO 1179-3) G1/4 A-L (ISO 1179-2) Schrader (SAE J512) ø15,9 [0.63] M1: M12 x 1.5 (ISO 6149-3) N1: 1/4-18 NPT Seal: O-ring (included) Seal: Pipe thread Mating geometry: ISO 6149-1 Mating geometry: ANSI B1.20.1 Installation torque: 25 N m [18.4 ft-lb] Installation torque: Two to three turns from finger tight Weight: 33,9 g to 38,9 g [1.2 oz to 1.4 oz] Weight: 35,1 g to 40,1 g [1.2 oz to 1.4 oz] ø17,0 ø17,0 [0.67] [0.67] ø21,6 ø21,6 [0.85] [0.85] 34,9 35 [1.37] [1.4] 48,4 50 [1.91] [2.0] 13 12,9 [0.5] [0.51] 15,0 13,5 O-ring [0.53] [0.59] 1/4-18 NPT M12 x 1.5 (ISO 6149-3) N2: 1/8-27 NPT T1: Tube ø17,0 Seal: Pipe thread Seal: Brazing [0.67] Mating geometry: ANSI B1.20.1 Weight: 32 g [1.1 oz] Installation torque: Two to three turns from finger tight Weight: 31,2 g to 36.2 g [1.1 oz to 1.3 oz] ø17,0 39,5 [0.67] [1.56] ø21,6 96,5 [0.85] [3.80] 36 [1.4] ø23,0 [0.91] 46 Ensure this area is [1.8] protected during the 57,0 14 brazing process so [2.24] [0.5] that temperatures do not exceed 125°C [257°F]. 7,0 10,0 [0.27] [0.39] 1/8-27 NPT ø7,3 [0.29] ø6,35 [0.25] 6 Sensing and Internet of Things Heavy Duty Pressure Transducers PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi Figure 7. DIN Mounting Dimensions (For reference only. mm/[in].) E Pinout General product marking F1, G1, G2, M1, N1, N2 Ratiometric Voltage Output Pin 1 = Ground Pin 4 Pin 2 = V+ Pin 2 Pin 1 Pin 3 = Vout Yellow lettering Pin 4 (PE) = Not connected 22,0 [0.87] Current Output Pin 1 = Return Pin 2 = Supply Pin 3 Pin 3 = Not connected Pin 4 (PE) = Not connected F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512) G1: G1/4 A-G (ISO 1179-3) Seal: 45° cone Seal: O-ring (included) Mating geometry: SAE J512 Mating geometry: ISO 1179-1 Installation torque: 17 N m [12.5 ft-lb] Installation torque: 50 N m [36.9 ft-lb] Weight: 42 g to 47 g [1.5 oz to 1.7 oz] Weight: 36,1 g to 41,1 g [1.3 oz to 1.4 oz] 16,9 ø16,9 [0.66] [0.66] ø21,60 ø21,60 37,4 [0.85] [0.85] [1.47] 28,9 [1.14] 42,6 15,4 40,1 [1.68] [0.61] 13,9 [1.58] [0.55] 12,2 O-ring [0.48] 11,2 7/16-20 UNF 1/4 in 45° Flare Female [0.44] Schrader (SAE J512) G1/4 A-G (ISO 1179-3) ø15,9 [0.63] G2: G1/4 A-L (ISO 1179-2) M1: M12 x 1.5 (ISO 6149-3) Seal: ISO 9974-2/DIN 3869 profile ring (included) Seal: O-ring (included) Mating geometry: ISO 1179-1 Mating geometry: ISO 6149-1 Installation torque: 50 N m [36.9 ft-lb] Installation torque: 25 N m [18.4 ft-lb] Weight: 36,1 g to 41,1 g [1.3 oz to 1.4 oz] Weight: 34,9 g to 39,9 g [1.2 oz to 1.4 oz] , ø16,9 ø17,0 [0.66] [0.67] ø21,60 ø21,60 [0.85] 27,9 [0.85] 27,9 [1.10] [1.10] 41,9 41,4 12,9 12,9 [1.65] [1.63] [0.51] [0.51] 14,0 13,5 Profile ring O-ring [0.55] [0.53] M12 x 1.5 (ISO 6149-3) G1/4 A-L (ISO 1179-2) N1: 1/4-18 NPT N2: 1/8-27 NPT Seal: Pipe thread Seal: Pipe thread Mating geometry: ANSI B1.20.1 Mating geometry: ANSI B1.20.1 Installation torque: Two to three turns from finger tight Installation torque: Two to three turns from finger tight Weight: 36,1 g to 41,1 g [1.3 oz to 1.4 oz] Weight: 32,2 g to 37,2 g [1.1 oz to 1.3 oz] ø16,9 ø16,9 [0.66] [0.66] ø21,60 [0.85] ø21,6 29 28 [0.85] [1.1] [1.1] 13 43 39 [0.5] [1.7] 14 [1.5] [0.5] 15,0 10,0 [0.59] 1/4-18 NPT [0.39] 1/8-27 NPT Sensing and Internet of Things 7 Heavy Duty Pressure Transducers PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi Figure 8. Cable Harness Mounting Dimensions (For reference only. mm/[in].) E Wire colors F1, G1, G2, M1, N1, N2 T1 General product marking 22,0 3-wire Voltage Output [0.87] cable Black = Ground Red = V+ White = Vout White label with black lettering Current Output Black = Return Red = Supply 22,0 2-wire [0.87] cable F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512) G1: G1/4 A-G (ISO 1179-3) Seal: 45° cone Seal: O-ring (included) Mating geometry: SAE J512 Mating geometry: ISO 1179-1 Installation torque: 17 N m [12.5 ft-lb] Installation torque: 50 N m [36.9 ft-lb] Weight: 90 g to 88 g [3.2 oz to 3.1 oz] Weight: 70 g to 68 g [2.5 to 2.4 oz] 3-Wire 2-Wire 3-Wire 2-Wire Cable Cable Cable Cable 1000 ±50 1000 ±50 1000 ±50 1000 ±50 [39.9 ±1.9] [39.9 ±1.9] [39.9 ±1.9] [39.9 ±1.9] 33,1 [1.30] 31,6 ø21,6 [1.24] ø21,6 [0.85] [0.85] 45,3 42,75 15,4 [1.78] [1.683] 13,9 [0.61] [0.55] 7/16-20 UNF 1/4 in 45° Flare 12,2 11,2 [0.48] Female Schrader (SAE J512) O-Ring [0.44] G1/4 A-G (ISO 1179-3) ø15,9 [0.63] G2: G1/4 A-L (ISO 1179-2) M1: M12 x 1.5 (ISO 6149-3) Seal: ISO 9974-2/DIN 3869 profile ring (included) Seal: O-ring (included) Mating geometry: ISO 1179-1 Mating geometry: ISO 6149-1 Installation torque: 50 N m [36.9 ft-lb] Installation torque: 25 N m [18.4 ft-lb] Weight: 70 g to 68 g [2.5 oz to 2.4 oz] Weight: 69 g to 67 g [2.4 oz] 3-Wire 2-Wire Cable Cable 3-Wire 2-Wire Cable Cable 1000 ±50 1000 ±50 [39.9 ±1.9] [39.9 ±1.9] 1000 ±50 1000 ±50 [39.9 ±1.9] [39.9 ±1.9] 30,6 [1.20] 30,6 ø21,6 [1.20] ø21,6 [0.85] [0.85] 44,55 12,9 [1.754] 44,1 [0.51] 12,9 [1.73] [0.51] 14,0 Profile ring [0.55] 13,5 O-Ring [0.53] G1/4 A-L (ISO 1179-2) M12 x 1.5 (ISO 6149-3) 8 Sensing and Internet of Things Heavy Duty Pressure Transducers PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi Figure 8. Cable Harness Mounting Dimensions (For reference only. mm/[in].) E N1: 1/4-18 NPT N2: 1/8-27 NPT Seal: Pipe thread Seal: Pipe thread Mating geometry: ANSI B1.20.1 Mating geometry: ANSI B1.20.1 Installation torque: Two to three turns from finger tight Installation torque: Two to three turns from finger tight Weight: 70 g to 68 g [2.5 oz to 2.4 oz] Weight: 66 g to 64 g [2.3 oz] 3-Wire 2-Wire 3-Wire 2-Wire Cable Cable Cable Cable 1000 ±50 1000 ±50 1000 ±50 [39.9 ±1.9] [39.9 ±1.9] 1000 ±50 [39.9 ±1.9] [39.9 ±1.9] 30,6 31,6 [1.20] ø21,6 [1.24] [0.85] ø21,6 [0.85] 45,6 12,9 41,6 [1.79] [0.51] [1.64] 13,9 [0.55] 15,0 10,0 [0.59] 1/4-18 NPT [0.39] 1/8-27 NPT T1: Tube 3-Wire 2-Wire Seal: Brazing Cable Cable Weight: 67 g [2.4 oz] 1000 ±50 1000 ±50 [39.9 ±1.9] [39.9 ±1.9] ø23,0 [0.91] 32,2 [1.38] 92,2 [3.63] Ensure this area is protected during the 57,0 brazing process so that [2.24] temperatures do not exceed 125°C [257°F]. 7,0 [0.27] ø7,3 [0.29] ø6,35 [0.25] Sensing and Internet of Things 9 ADDITIONAL INFORMATION WARNING The following associated literature is available on the PERSONAL INJURY Honeywell web site at sensing.honeywell.com: DO NOT USE these products as safety or emergency stop • Product line guide devices or in any other application where failure of the • Product range guide product could result in personal injury. • Product installation instructions Failure to comply with these instructions could result in • Application notes: death or serious injury. - Heavy Duty Pressure Transducers, PX2 Series and PX3 Series WARNING - PX2 Series and PX3 Series Heavy Duty Pressure MISUSE OF DOCUMENTATION Transducers for Potential Use in Industrial Refrigeration • The information presented in this datasheet is for - PX2 Series and PX3 Series Heavy Duty Pressure reference only. Do not use this document as a product Transducers for Potential Use in Industrial HVAC/R installation guide. Applications • Complete installation, operation, and maintenance • Technical notes: information is provided in the instructions supplied with - Total Error Band Specification for Honeywell Heavy each product. Duty Pressure Transducers, PX2 Series and PX3 Series Failure to comply with these instructions could result in - Media Compatibility for Honeywell Heavy Duty death or serious injury. Pressure Transducers, PX2 Series and PX3 Series • CAD models Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it For more information is buyer’s sole responsibility to determine the suitability of the Honeywell Sensing and Internet of product in the application. Things services its customers through a Specifications may change without notice. The information we worldwide network of sales offices and distributors. For application assistance, supply is believed to be accurate and reliable as of this writing. current specifications, pricing or the However, Honeywell assumes no responsibility for its use. nearest Authorized Distributor, visit sensing.honeywell.com or call: Asia Pacific +65 6355-2828 Europe +44 (0) 1698 481481 ® Solstice N40 is a registered trademark USA/Canada +1-800-537-6945 of Honeywell International Inc. Honeywell Sensing and Internet of Things 9680 Old Bailes Road Fort Mill, SC 29707 32313757-E-EN | E | 01/18 www.honeywell.com © 2018 Honeywell International Inc.

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the PX3AN2BS100PAAAX?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Pressure Sensor 0psi to 1psi 4-Pin 136PC01G2

product

Pressure Sensor 0psi to 15psi Gage 4-Pin 136PC15G2L

product

Pressure Sensor 0psi to 15psi Gage 4-Pin 136PC15G3L23

product

Pressure Sensor 0psi to 500psi Absolute 4-Pin 13C0500PA1K

product

Pressure Sensor 0psi to 500psi Absolute 4-Pin 13C0500PA1L

product

Pressure Sensor 0psi to 500psi Absolute 4-Pin 13C0500PA4K