Electronics Finder chervon right Manufacturers chervon right I chervon right IDEC CORPORATION chervon right HW1K-21B10
About product Specifications Datasheet FAQ

IDEC CORPORATION HW1K-21B10

Image of IDEC CORPORATION HW1K-21B10

Description

Switch Key Lock N.O. SPST 60° Flat Key Screw 500000Cycles Panel Mount
HW1K-21B10

Part Number

HW1K-21B10

Price

Request Quote

Manufacturer

IDEC CORPORATION

Lead Time

Request Quote

Category

Switches »  Switch KeyLock

Specifications

Manufacturer

IDEC Corporation

Manufacturers Part #

HW1K-21B10

Sub-Category

KeyLock Switches

Factory Pack Quantity

1

Datasheet

pdf file

EP1056-0_HWscreen.pdf

3116 KiB

Extracted Text

�������� ���� � ���������������� ������� ������ ø22mm HW Series Control Units ������������ ����� ���������������� ������� �� ��! ø22 HW Series Control Units (Selection Guide) Function Emergency Stop Switch (Unibody Type) Emergency Stop Switch (Separate Type) Pushlock Turn Reset Category ø40mm Mushroom ø40mm Mushroom ø29mm Mushroom ø40mm Mushroom ø60mm Mushroom Shape Type HW1E-BV4 HW1E-LV4 HW1B-V3 HW1B-V4 HW1B-V5 Page 9 10 111111 Function Emergency Stop Switch Pushbutton Pushlock Key Reset Push Pull Pushlock Turn Reset Flush Extended Category ø40mm Mushroom ø40mm Mushroom ø40mm EMO Momentary/Maintained Shape HW1B-M1 HW1B-M2 Type HW1B-X4 HW1B-Y2 HW1B-V∗∗R-EMO HW1B-A1 HW1B-A2 Page 12 12 14 15 15 Function Pushbutton ø29mm Mushroom ø40/60mm Mushroom Square Flush Square Extended Flush Category Momentary/Maintained Shape HW1B-M4 HW1B-M3 HW2B-M1 HW2B-M2 HW3B-M1 Type HW1B-A4 HW1B-A3 HW2B-A1 HW2B-A2 HW3B-A1 HW1B-M5 Page 15 15 16 16 17 Function Pushbutton Pilot Light (LED/Incandescent) Round Extended ø29mm Mushroom w/Square Bezel w/Square Bezel Category Flush (Marking) Extended (Dome) Square Flush (Marking) Momentary/Maintained Shape HW3B-M2 HW3B-M3 Type HW1P-1 HW1P-2 HW2P-1 HW3B-A2 HW3B-A3 Page 17 17 18 18 18 Function Illuminated Pushbutton (LED/Incandescent) Category Flush Extended Extended w/Full Shroud Square Flush (Marking) Flush w/Square Bezel Shape HW1L-M1 HW1L-M2 HW1L-MF2 HW2L-M1 HW3L-M1 Type HW1L-A1 HW1L-A2 HW1L-AF2 HW2L-A1 HW3L-A1 Page 19 20 21 22 23 2 ���������������� ������������������������� ��! HW Series Control Units (Selection Guide) ø22 Function Illuminated Pushbutton Switch (LED/Incandescent) Illuminated Selector Switch ø29mm Mushroom Category ø29mm Mushroom ø40mm Mushroom (LED/Incandescent) w/ Square Bezel Shape HW1L-M3 HW3L-M3 HW1L-M4 Type HW1F HW1L-A3 HW3L-A3 HW1L-A4 Page 24 25 26 30 Function Selector Switch Mono-Lever Switch Pushbutton Selector Category Selector Key Standard Interlocking Shape Type HW1S HW1K HW1R HW1M HW1M-L Page 28 29 37 38 38 Function Control Box Emergency Stop Control Box w/Pushlock Turn w/Pushlock Key Category w/Pushbutton w/Selector Switch Reset Switch Reset Switch Shape Type HW1X-BM HW1X-S HW1X-BV HW1X-BX Page 48 48 48 48 Safety Lever Lock HW9Z-LS Every HW series control unit, except for pilot lights and unibody type emergency stop switches, is supplied with the HW9Z-LS safety lever lock. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from unlocking contacts. 3 ���������������� ����� ���������������������� ����� ø22 HW Series Control Units Complete with IP20 finger-safe contact blocks Ensure safety and save wiring time • The locking lever removable contact block features spring-up screw terminals. • Self-cleaning rolling action contacts have a raked contact sur- face. • Degree of protection: IP65 • A wide range of operating voltages for worldwide application • UL, CSA approved, and EN compliant Safety Standards File No. or Organization UL Listing UL File No. E68961 CSA File No. LR92374 EN60947-1 EN TÜV Rheinland R9551089 EN60947-5-1 Specifications and Ratings Contact Ratings Contact Block Type HW-G (HW series) Pushbuttons Rated Insulation Voltage 600V Illuminated Pushbuttons Selector Switches Rated Continuous Current 10A Illuminated Selector Switches Contact Ratings by Utilization Category AC-15 (A600) Pushbutton Selectors IEC 60947-5-1 DC-13 (P600) Characteristics • Contact Ratings by Utilization Category Operational Voltage 24V 48V 50V 110V 220V 440V AC-12 Control of resistive loads and solid state loads 10A — 10A 10A 6A 2A AC 50/60 Hz AC-15 Control of electromagnetic loads (> 72 VA) 10A — 7A 5A 3A 1A Operational Current DC-12 Control of resistive loads and solid state loads 8A 4A — 2.2A 1.1A — DC DC-13 Control of electromagnets 4A 2A — 1.1A 0.6A — Note: The operational current represents the classification by making and breaking currents (IEC 60947-5-1). Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types) For the control units listed below, the rated current (load switching current) is reduced to a half of the rated operational current of the con- tact block. The rated insulation voltage (600V) and the rated thermal current (10A) remain unchanged. • 3-position selector switches which contain J or S following 3 in the Type No. and which have cam code J or S. Example: HW1S-3JT21N1 • All 4-position and 5-position selector switches • All mono-lever switches • All pushbutton selectors HW-G Contact Block Transformer Unit • Finger-safe terminal Compliant to VDE 0106 Part 100 • Double-break rolling action silver • Snap-fit latch contacts with raked surface • Housing in different colors for NO and NC contact. • Insertion from two directions • Ring or fork connectors can also be used. • Spring-up terminal is ready for wiring. • Finger-safe spring-up terminal Screw is held captive. • Wires can be inserted from • Push rod three directions. Color-coded for different contacts • Contact Block Types Type No. HW-G10 HW-G01 HW-G10R HW-G01R Contact NO NC NO (early make) NC (late break) Housing Blue Purple red Blue Purple red Push Rod Green Red Black White 4 ���������������� ����! ���������������������� ����� HW Series Control Units ø22 LED Illuminated Unit Specifications LED Lamp Unit Color Code ➁ Input Type Operating Voltage Lamp Base Type No. Voltage 6V AC/DC LSTD-6➁ 6V AC/DC ±10% Full Voltage 12V AC/DC LSTD-1➁ 12V AC/DC ±10% 24V AC/DC LSTD-2➁ 24V AC/DC ±10% A: amber 100/110V AC/DC G: green 115/120V AC/DC Pilot Light PW: pure white 200/220V AC/DC Illuminated Pushbutton R: red BA9S/13 230/240V AC/DC S: blue Illuminated Selector Switch Transformer LSTD-6➁ 6V AC/DC ±10% 380V AC/DC W: white 400/440V AC/DC Y: yellow 480V AC/DC (50/60 Hz) DC-DC Converter 110V DC LSTD-6➁ 6V AC/DC ±10% Incandescent Illuminated Unit Specifications Incandescent Lamp Unit Color Code ➁ Input Type Operating Voltage Lamp Base Type No. Rating 6V AC/DC LS-6 1W (6.3V) Full Voltage 12V AC/DC LS-8 1W (18V) 24V AC/DC LS-3 1W (30V) A: amber 100/110V AC/DC Pilot Light G: green 115/120V AC/DC Illuminated Pushbutton R: red BA9S/13 200/220V AC/DC S: blue Illuminated Selector Switch 230/240V AC/DC Transformer LS-6 1W (6.3V) W: white 380V AC/DC 400/440V AC/DC 480V AC/DC (50/60 Hz) LED Lamp Ratings (LSTD Type) Type No. LSTD-6➁ LSTD-1➁ LSTD-2➁ Lamp Base BA9S/13 Rated Voltage 6V AC/DC 12V AC/DC 24V AC/DC Voltage Range 6V AC/DC ±10% 12V AC/DC ±10% 24V AC/DC ±10% A, R, W, Y: 17 mA AC 11 mA 11 mA G, PW, S: 8 mA Current Draw A, R, W, Y: 14 mA DC 10 mA 10 mA G, PW, S: 5.5 mA Color Code A (amber), G (green), PW (pure white), R (red), S (blue), W (white), Y (yellow) Lamp Base Color Same as illumination color Voltage Marking Die stamped on the base Approx. 50,000 hours Life (reference value) (The luminance reduces to 50% the initial intensity when used on complete DC.) A, R, W, Y A, R, W, Y Internal Circuit G, PW, S LED Chip Protection Diode Zener Diode Incandescent Lamp Ratings (LS Type) Type No. LS-6 LS-8 LS-2 LS-3 Lamp Base BA9S/13 Rated Voltage 6V AC/DC 12V AC/DC 18V AC/DC 24V AC/DC Wattage 1W (6.3V) 1W (18V) 1W (24V) 1W (30V) Voltage Marking Die stamped on the base Approx. 1,000 hours minimum Life (reference value) (mean value when used on the rated voltage) 5 +0.4 0 ø22.3 ���������������� ����" ���������������������� ����� ø22 HW Series Control Units Specifications –25 to +60°C (no freezing) Operating Temperature Illuminated units: –25 to +50°C Storage Temperature –40 to +80°C Operating Humidity 45 to 85% RH (no condensation) Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Between live and dead metal parts: 2,500V AC, 1 minute Dielectric Strength (Full voltage type illuminated units: 2,000V AC, 1 minute) Vibration Resistance Operating extremes: 5 to 55 Hz, amplitude 0.5 mm 2 Damage limits: 1,000 m/s Shock Resistance 2 Operating extremes: 100 m/s Pushbuttons, Illuminated pushbuttons Momentary: 5,000,000 Maintained: 500,000 Mechanical Life Selector switches: 500,000 (minimum operations) Key selector switches: 500,000 Illuminated selector switches: 500,000 Pushbutton selectors: 250,000 Mono-lever switches: 250,000 Pushbuttons, Illuminated pushbuttons: 500,000 ∗1 Selector switches: 500,000 ∗2 Key selector switches: 500,000 ∗2 Illuminated selector switches: 500,000 ∗2 Electrical Life Pushbutton selectors: 250,000 ∗2 (minimum operations) Mono-lever switches: 250,000 ∗3 ∗1 Switching frequency 1,800 operations/h, duty ratio 40% ∗2 Switching frequency 1,200 operations/h, duty ratio 40% ∗3 Switching frequency 900 operations/h, duty ratio 40% Degree of Protection Unit NEMA ICS 6-110 IEC 60529 Type All units IP65 1, 2, 3, 3R, (3S), 4, 5, 12,13 Mounting Hole Layout The minimum mounting centers are applicable to switches with one R0.8 maximum layer of contact blocks (two contact blocks). When two layers of +0.2 ∗3.2 0 contact blocks are mounted, determine the minimum mounting cen- ters in consideration of convenience for wiring. • Minimum Mounting Centers Unit ∗ ∗ ∗ ∗1 ∗ ∗ ∗ ∗2 ø40mm mushroom button 50 mm 40 mm 30 Pilot light 30 mm 30 mm (∗2) Pushbutton selector 50 mm 50 mm Mono-lever switch 72 mm 72 mm Note: When using the safety lever lock, determine the vertical spacing (*1) in consideration of convenience for installing and removing the safety lever lock. ∗ The 3.2 mm recess is for preventing rotation Recommended vertical spacing: 100 mm and is not necessary when the nameplate or anti-rotation ring is not used. 6 50 (∗1) (45 minimum) +0.4 24.1 0 ���������������� ����# ���������������������� ����� HW Series Control Units (Ordering Information) ø22 Ordering Information The Type No. development charts shown below can be used to specify control units other than those listed on the following pages. Gold-plated silver contacts are also available. Emergency Stop Switches Illuminated Pushbuttons For emergency stop purposes, these switches must contain HW1L-M1 11 H 2 R -MAU at least one NC contact block. Optional contact HW1B-V4 11 R -MAU MAU: Gold-plated silver contact Optional contact Lens color code MAU: Gold-plated silver contact Lamp code Button/lens color code 0: Without lamp 2: LED (6V: LSTD) Contact arrangement code 3: LED (12V: LSTD) 01: 1NC 11: 1NO-1NC 4: LED (24V: LSTD) 02: 2NC 21: 2NO-1NC 5: Incandescent (6V: LS-6) 12: 1NO-2NC 03: 3NC 6: Incandescent (12V: LS-8) 31: 3NO-1NC 22: 2NO-2NC 7: Incandescent (24V: LS-3) 13: 1NO-3NC 04: 4NC Operating voltage code Note: Q: Full voltage Push-pull type HW1B-Y2 can have a maximum of two contact H: Transformer (100/110V AC) blocks. H2: Transformer (115/120V AC) M: Transformer (200/220V AC) M4: Transformer (230/240V AC) Pushbuttons S: Transformer (380V AC) T: Transformer (400/440V AC) HW1B-M1 11 R -MAU T8: Transformer (480V AC) Optional contact D: DC-DC converter (110V DC) MAU: Gold-plated silver contact Contact arrangement code Button color code 10: 1NO 01: 1NC Contact arrangement code 11: 1NO-1NC 20: 2NO 10: 1NO 01: 1NC 02: 2NC 21: 2NO-1NC 11: 1NO-1NC 20: 2NO 12: 1NO-2NC 30: 3NO 02: 2NC 21: 2NO-1NC 03: 3NC 31: 3NO-1NC 12: 1NO-2NC 30: 3NO 22: 2NO-2NC 13: 1NO-3NC 03: 3NC 31: 3NO-1NC 40: 4NO 04: 4NC 22: 2NO-2NC 13: 1NO-3NC 40: 4NO 04: 4NC Note: Full voltage type is not supplied with a lamp. Transformer and DC-DC converter types contain an LED lamp Pilot Lights (LSTD-6➁) or incandescent lamp (LS-6). Transformer and DC-DC converter types can have two or four HW1P-1 H 2 R contact blocks only. Lens color code Lamp code 0: Without lamp Selector Switches 2: LED (6V: LSTD) 3: LED (12V: LSTD) HW1S-3 S T 22N9 -MAU 4: LED (24V: LSTD) Optional contact 5: Incandescent (6V: LS-6) MAU: Gold-plated silver contact 6: Incandescent (12V: LS-8) Contact code 7: Incandescent (24V: LS-3) Knob operator Operating voltage code Cam code Q: Full voltage J H: Transformer (100/110V AC) S H2: Transformer (115/120V AC) (none) M: Transformer (200/220V AC) M4: Transformer (230/240V AC) S: Transformer (380V AC) T: Transformer (400/440V AC) T8: Transformer (480V AC) D: DC-DC converter (110V DC) Note: Full voltage type is not supplied with a lamp. Transformer and DC-DC converter types contain an LED lamp (LSTD-6➁) or incandescent lamp (LS-6). 7 ���������������� ����$ ���������������������� ����� ø22 HW Series Control Units (Ordering Information) Key Selector Switches HW1K-2 A 11 - 1H -MAU Optional contact MAU: Gold-plated silver contact Different key number 1H 2H 3H Key removal position code 2-position A: Removable in all positions B: Removable in left only C: Removable in right only 3-position A: Removable in all positions B: Removable in left and center C: Removable in right and center D: Removable in center only E: Removable in right and left G: Removable in left only H: Removable in right only Note: Key is not removable from spring-return positions. Illuminated Selector Switches HW1F-2 11 H 2 R -MAU Optional contact MAU: Gold-plated silver contact Lens color code Lamp code 0: Without lamp 2: LED (6V: LSTD) 3: LED (12V: LSTD) 4: LED (24V: LSTD) 5: Incandescent (6V: LS-6) 6: Incandescent (12V: LS-8) 7: Incandescent (24V: LS-3) Operating voltage code Q: Full voltage H: Transformer (100/110V AC) H2: Transformer (115/120V AC) M: Transformer (200/220V AC) M4: Transformer (230/240V AC) S: Transformer (380V AC) T: Transformer (400/440V AC) T8: Transformer (480V AC) Note: Full voltage type is not supplied with a lamp. Transformer type contains an LED lamp (LSTD-6➁) or incandes- cent lamp (LS-6). Pushbutton Selectors HW1R-2 D 22N1 B -MAU Optional contact MAU: Gold-plated silver contact Button color code Contact code Circuit category Mono-Lever Switches HW1M - 1111 22N9 -MAU Optional contact MAU: Gold-plated silver contact Contact code Lever operation mode 8 ��������� ����� ���������������������� ����� HW Series Emergency Stop Switches ø22 Emergency Stop Switches (Unibody Type) Specifications Contact Ratings Rated Insulation Voltage (Ui) 250V Rated Thermal Current (Ith) 10A Rated Operational Voltage (Ue) 24V 110V 220V Resistive Load (AC-12) 6A 3A 3A AC Rated 50/60 Hz Inductive Load (AC-15) 6A 3A 3A Operational Resistive Load (DC-12) 6A 2A 1A Current DC Inductive Load (DC-13) 1.5A 0.3A 0.15A Note: The operational current represents the classification by making and breaking currents (IEC 60947-5-1). Minimum applicable load (reference value): 3V AC/DC, 5 mA (Applicable range may vary with operating conditions and load types.) LED Lamp Ratings Specifications LED Lamp Operating –25 to +60°C (no freezing) Unit Rated Temperature Operating Illuminated units: –25 to +50°C Rated Type No. Rated Voltage Voltage Current Storage Temperature –40 to +80°C 6V AC/DC LSTD-6R 6V AC/DC ±10% 14 mA Operating Humidity 45 to 85% RH (no condensation) 12V AC/DC LSTD-1R 12V AC/DC ±10% 10 mA Contact Resistance 50 mΩ maximum (initial value) 24V AC/DC LSTD-2R 24V AC/DC ±10% 10 mA Insulation Resistance 100 MΩ minimum (500V DC megger) Between live and dead metal parts Dielectric Strength Contacts: 2,500V AC, 1 minute Incandescent Lamp Ratings Illuminated parts: 1,000V AC, 1 minute Unit Rated Incandescent Lamp 2 Damage limits: 60 m/s Operating Vibration Resistance Type No. Wattage Operating extremes: 5 to 55 Hz, amplitude 0.5 mm Voltage 2 Damage limits: 1,000 m/s 6V AC/DC LS-6 1W (6.3V) Shock Resistance 2 Operating extremes: 100 m/s 12V AC/DC LS-8 1W (18V) Operating Frequency 900 operations/h 24V AC/DC LS-3 1W (30V) Mechanical: 250,000 operations minimum Life Electrical: 100,000 operations minimum (at 900 operations/h, duty ratio 40%) Degree of Protection IP65 Terminal Style M3.5 screw Applicable Standards and Approvals Safety Standards File No. or Organization UL508 UL Listing File No. E55996 CSA C22.2 No. 14 c-UL (File No. E55996) EN60947-5-5 DEMKO approved Pushlock Turn Reset Switches (Unibody Type) Shape Contact Type No. Button Color ø40mm Mushroom Pushlock Turn Reset HW1E-BV4 1NO-1NC HW1E-BV411R Red only 2NC HW1E-BV402R • When pressed, the button is held depressed. The button is released by turning clockwise. • Terminal cover HW-VL7 is supplied with the switch. 9 +0.4 0 ø22.3 ��������� ������ ���������������������� ����� ø22 HW Series Emergency Stop Switches Illuminated Pushlock Turn Reset Switches (Unibody Type) Shape Lamp Contact Type No. Lens Color ø40mm Mushroom Pushlock Turn Reset HW1E-LV4 1NO-1NC HW1E-LV411Q0R Without Lamp Red only 2NC HW1E-LV402Q0R • When pressed, the button is held depressed. The button is released by turning clockwise. • The illuminated pushlock turn reset switch does not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. • Terminal cover HW-VL7 is supplied with the switch. Dimensions • HW1E-BV4 Panel Thickness 0.8 to 6 Gasket M3.5 Terminal Screw Locking Ring TOP Marking 11.5 14 Terminal Cover 46 32 48 • HW1E-LV4 Panel Thickness 0.8 to 6 M3.5 Terminal Screw Gasket Locking Ring TOP Marking M3.5 Terminal Screw Lamp Terminal 11.5 14 61 32 Terminal Cover 63 All dimensions in mm. Mounting Hole Terminal Arrangement (Bottom View) • HW1E-BV4 • HW1E-LV4 R0.8 max. +0.2 3.2 0 TOP Side X1 LAMP .2 (NC) .3 (NO) .2 (NC) .3 (NO) .1 (NC) .4 (NO) .1 (NC) .4 (NO) Determine the minimum mounting hole centers in consideration of convenience for wiring. (1NO-1NC) X2 (1NO-1NC) Replacement Parts Name Type No. Ordering Type No. Package Quantity Remarks Used on HW1E emergency stop switches for preventing electrical shocks. Terminal Cover HW-VL7 HW-VL7PN10 10 The HW-VL7 terminal cover is supplied with the HW1E. 10 +0.4 24.1 0 ø40 ø 40 ��������� ������ ���������������������� ����� HW Series Emergency Stop Switches ø22 Emergency Stop Switches (Separate Type) Specifications Contact Ratings Specifications Rated Insulation Voltage 600V Operating Temperature –25 to +60°C (no freezing) Rated Continuous Current 10A Storage Temperature –40 to +80°C Contact Block Contact Ratings by Utilization Category AC-15 (A600) Operating Humidity 45 to 85% RH (no condensation) IEC 60947-5-1 DC-13 (P600) Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Characteristics Between live and dead metal parts Between terminals of different poles • Contact Ratings by Utilization Category Dielectric Strength Between terminals of the same pole Operational Voltage 24V 48V 50V 110V 220V 440V 2,500V AC, 1 minute AC-12 Control of Operating extremes: Vibration Resistance resistive loads and 10A — 10A 10A 6A 2A 5 to 55 Hz, amplitude 0.5 mm solid state loads AC 2 Damage limits: 1,000 m/s Shock Resistance 50/60 Hz AC-15 Control of 2 Operating extremes: 100 m/s electromagnetic 10A — 7A 5A3A1A Operating loads (> 72 VA) 900 operations/h Frequency DC-12 Control of Mechanical: resistive loads and 8A 4A — 2.2A 1.1A — 500,000 operations minimum solid state loads DC (push-pull: 250,000 operations) DC-13 Control of Life Electrical: 4A 2A — 1.1A 0.6A — electromagnets 500,000 operations minimum (push-pull: 250,000 operations) (at 900 operations/h, duty ratio 40%) Applicable Standards and Approvals Degree of Protection IP65 Safety Standards File No. or Organization Terminal Style M3.5 screw UL Listing UL File No. E68961 CSA C22.2 No. 14 File No. LR92374 EN60947-1 EN TÜV Rheinland R9551089 EN60947-5-1 Pushlock Turn Reset Switches (Separate Type) Shape Contact Type No. Button Color ø29mm Mushroom Pushlock Turn Reset 1NC HW1B-V301➀ HW1B-V3 1NO-1NC HW1B-V311➀ 2NC HW1B-V302➀ 2NO-2NC HW1B-V322➀ ø40mm Mushroom Pushlock Turn Reset 1NC HW1B-V401➀ HW1B-V4 Specify a button color code in 1NO-1NC HW1B-V411➀ place of ➀ in the Type No. R: red 2NC HW1B-V402➀ Y: yellow 2NO-2NC HW1B-V422➀ ø60mm Mushroom Pushlock Turn Reset 1NC HW1B-V501➀ HW1B-V5 1NO-1NC HW1B-V511➀ 2NC HW1B-V502➀ 2NO-2NC HW1B-V522➀ • Yellow buttons cannot be used as emergency stop switches in compliance with EN standards. • When pressed, the button is held depressed. The button is released by turning clockwise. • Pushlock turn reset switches with one or three contact blocks contain a dummy block. • Safety lever lock HW9Z-LS is supplied with the switch. • Other contact arrangements and gold-plated silver contacts are also available. See page 7. 11 Operational Current ø 22 ��������� ������ ���������������������� ����� ø22 HW Series Emergency Stop Switches Pushlock Key Reset Switches (Separate Type) Shape Contact Type No. Button Color ø40mm Mushroom Pushlock Key Reset 1NC HW1B-X401R HW1B-X4 1NO-1NC HW1B-X411R Red only 2NC HW1B-X402R 2NO-2NC HW1B-X422R • When pressed, the button is held depressed. The button is released by turning the key clockwise. • Pushlock key reset switches with one or three contact blocks contain a dummy block. • Two identical keys and safety lever lock HW9Z-LS are supplied with the switch. • Other contact arrangements and gold-plated silver contacts are also available. See page 7. Push-Pull Switches (Separate Type) Shape Contact Type No. Button Color ø40mm Mushroom Push-Pull (2-position) HW1B-Y2 1NC HW1B-Y201➀ Specify a button color code in place of ➀ in the Type No. 1NO-1NC HW1B-Y211➀ R: red Y: yellow 2NC HW1B-Y202➀ • The button is maintained at either pulled or depressed position. • Push-pull switches are available with one or two contact blocks. • Push-pull switches with one contact block contain a dummy block. • Safety lever lock HW9Z-LS is supplied with the switch. Accessory Nameplate Package Shape Name Type No. Legend Remarks Quantity Background: Yellow Legend: Black HWAV-0 (blank) Applicable panel thickness: 0.8 to 4.5 mm Nameplate for Material: Polyamide 1 Emergency Stop Switch Not applicable for ø60mm mushroom buttons. 1.5 0.9 EMERGENCY HWAV-27 Legend “EMERGENCY STOP” STOP is indicated outside a ø44mm circle. 12 ø 60 LO LO LOCK LOCK CK CK +0.4 0 ø22.3 ��������� �����! ���������������������� ����� HW Series Emergency Stop Switches ø22 Dimensions • ø29mm Pushlock Turn Reset HW1B-V3 Panel Thickness 0.8 to 6 Gasket Terminal Screw M3.5 Locking Ring 49.4 (1 or 2 blocks) 13 29.4 1 contact block 2 contact blocks 4 contact blocks ( ) 69.4 4 blocks 32 • ø40mm Pushlock Turn Reset • ø60mm Pushlock Turn Reset HW1B-V4 HW1B-V5 13 29.4 15 32 34.5 • ø40mm Pushlock Key Reset • ø40mm Push-Pull HW1B-X4 HW1B-Y2 13 13 29.4 29.4 32 32 49.4 All dimensions in mm. Mounting Hole The minimum mounting centers shown below are applicable to emergency stop R0.8 max. switches with one layer of contact blocks (two contact blocks). When two layers of +0.2 contact blocks are mounted, determine the minimum mounting centers in consider- 3.2 0 ation of convenience for wiring. • Minimum Mounting Centers for Emergency Stop Switches Unit Vertical Spacing Horizontal Spacing HW1B-V3 HW1B-V4 50 mm 50 mm HW1B-X4 HW1B-Y2 HW1B-V5 60 mm 60 mm Note: When using the safety lever lock, determine the vertical spacing in consideration of con- venience for installing and removing the safety lever lock. Recommended vertical spacing: 100 mm For emergency stop control boxes, see page 48. 13 +0.4 24.1 0 ø40 25 ø40 25 41.4 41.4 ø29 25 ø40 ø60 25 41.4 41.4 ø22.2 ø90 LOCK ��������� ������ ���������������������� ����� ø22 HW Series Emergency Stop Switches EMO is an abbreviation of Emergency Off. Used for emergency stop according to SEMI standards. EMO Pushbuttons Shape Contact Type No. Button Color ø40mm EMO Pushbuttons 1NC HW1B-V401R-EMO HW1B-V4∗∗R-EMO 1NO-1NC HW1B-V411R-EMO Red only (Legend: White) 2NC HW1B-V402R-EMO 2NO-2NC HW1B-V422R-EMO Dimensions Lock Lever Locking Ring 49.4 (1 or 2 blocks) 13 29.4 69.4 (4 blocks) All dimensions in mm. 32 SEMI Standard Compliant Switch Guards (For ø22mm mounting hole) • SEMI S2-0200 12.5.1 Compliant • Type No.: HW9Z-KG1 • Dimensions • Installation TOP Marking • Degree of Protection: IP65 38 64 TOP Marking Locking Ring • Color: Yellow 48 22 Operator Gasket Panel Thickness: 1.2 to 4 Not applicable for ø60mm mushroom buttons. • SEMATECH Application Guide for SEMI S2-93, 12.4 Compliant • Type No.: HW9Z-KG2 • Dimensions • Installation TOP Marking 36.5 • Degree of Protection: IP65 TOP Marking • Color: Yellow Locking Ring Operator Panel Thickness: 1.2 to 4 Not applicable for ø60mm mushroom buttons. • EMO Sticker • Type No.: HW9Z-EMO-NPP • Package Quantity: 10 • Color: Yellow with red letter 50 EMO Caution International industrial standards such as European Union Directive, IEC60204-1, and JIS B9960-1 require that emergency stop switches must be installed in the manner in which the operator can access and operate the switches easily, and prohibit the use of switch guards. The HW9Z-KG1 and HW9Z-KG2 switch guards are used for the emergency stop switches installed on semiconductor manufacturing equipment only. Do not use the switch guards for emergency stop switches installed on machine systems such as machine tool and food processing systems. 14 ø22 ø40 26.5 20 25 80 20 32 41.4 ø76.1 LOCK LOCK LOCK LOCK ����� ������ �������� ���������� ���� ������ HW Series Pushbuttons ø22 Flush / Extended / Mushroom Types Operation ➀ Button Shape Contact Type No. Dimensions (mm) Type Color Code Flush 1NO HW1B-M110➀ HW1B-M1 1NC HW1B-M101➀ M3.5 Terminal HW1B-A1 Screw 1NO-1NC HW1B-M111➀ Momentary Panel Thickness Locking Ring 0.8 to 6 2NO HW1B-M120➀ 2NC HW1B-M102➀ 2NO-2NC HW1B-M122➀ 1NO HW1B-A110➀ 1NC HW1B-A101➀ 1NO-1NC HW1B-A111➀ 49.4 (1 or 2 blocks) 13 29.4 Maintained 69.4 (4 blocks) 2NO HW1B-A120➀ 2NC HW1B-A102➀ 2NO-2NC HW1B-A122➀ Extended 1NO HW1B-M210➀ HW1B-M2 1NC HW1B-M201➀ M3.5 Terminal Screw HW1B-A2 1NO-1NC HW1B-M211➀ Panel Thickness Momentary Locking Ring 0.8 to 6 2NO HW1B-M220➀ 2NC HW1B-M202➀ 2NO-2NC HW1B-M222➀ 1NO HW1B-A210➀ 1NC HW1B-A201➀ Specify a but- 13 1NO-1NC HW1B-A211➀ 29.4 ton color code Maintained 49.4 (1 or 2 blocks) 19 in place of ➀ in 2NO HW1B-A220➀ 69.4 (4 blocks) the Type No. 2NC HW1B-A202➀ 2NO-2NC HW1B-A222➀ B: black ø29mm Mushroom 1NO HW1B-M310➀ G: green HW1B-M3 1NC HW1B-M301➀ M3.5 Terminal R: red Screw HW1B-A3 1NO-1NC HW1B-M311➀ S: blue Panel Thickness Momentary Locking Ring 0.8 to 6 W: white 2NO HW1B-M320➀ Y: yellow 2NC HW1B-M302➀ 2NO-2NC HW1B-M322➀ 1NO HW1B-A310➀ 1NC HW1B-A301➀ 13 1NO-1NC HW1B-A311➀ 29.4 Maintained 49.4 (1 or 2 blocks) 23.2 2NO HW1B-A320➀ 69.4 (4 blocks) 2NC HW1B-A302➀ 2NO-2NC HW1B-A322➀ ø40mm Mushroom 1NO HW1B-M410➀ HW1B-M4 1NC HW1B-M401➀ M3.5 Terminal HW1B-A4 Screw 1NO-1NC HW1B-M411➀ Panel Thickness Momentary Locking Ring 0.8 to 6 2NO HW1B-M420➀ 2NC HW1B-M402➀ 2NO-2NC HW1B-M422➀ 1NO HW1B-A410➀ 1NC HW1B-A401➀ 13 1NO-1NC HW1B-A411➀ 29.4 Maintained 49.4 (1 or 2 blocks) 23.2 2NO HW1B-A420➀ 69.4 (4 blocks) 2NC HW1B-A402➀ 2NO-2NC HW1B-A422➀ ø60mm Mushroom M3.5 Terminal 1NO HW1B-M510➀ Screw HW1B-M5 Locking Ring Panel Thickness 0.8 to 6 Specify a but- 1NC HW1B-M501➀ ton color code in place of ➀ in 1NO-1NC HW1B-M511➀ the Type No. Momentary 2NO HW1B-M520➀ B: black G: green 2NC HW1B-M502➀ R: red 15 49.4 (1 or 2 blocks) 30 2NO-2NC HW1B-M522➀ 69.4 (4 blocks) • Pushbuttons with one or three contact blocks contain a dummy block. • Other contact arrangements and gold-plated silver contacts are also available. See page 7. 15 ø23.6 ø29 ø40 ø23.6 ø29 ø60 ø29 25 25 25 25 41.4 41.4 41.4 41.4 LO K LOCK C ����� ������ �������� ���������� ���� ������ ø22 HW Series Pushbuttons Square Flush / Square Extended Types Operation ➀ Button Shape Contact Type No. Dimensions (mm) Type Color Code Square Flush 1NO HW2B-M110➀ HW2B-M1 1NC HW2B-M101➀ M3.5 Terminal HW2B-A1 1NO-1NC HW2B-M111➀ Screw Momentary Panel Thickness 2NO HW2B-M120➀ Locking Ring 0.8 to 6 2NC HW2B-M102➀ 2NO-2NC HW2B-M122➀ 1NO HW2B-A110➀ 1NC HW2B-A101➀ Specify a but- 1NO-1NC HW2B-A111➀ ton color code 49.4 (1 or 2 blocks) 13 Maintained 24.8 in place of ➀ in 2NO HW2B-A120➀ 69.4 (4 blocks) 29.4 the Type No. 2NC HW2B-A102➀ 2NO-2NC HW2B-A122➀ B: black Square Extended 1NO HW2B-M210➀ G: green HW2B-M2 1NC HW2B-M201➀ R: red M3.5 Terminal HW2B-A2 Screw 1NO-1NC HW2B-M211➀ S: blue Momentary Panel Thickness W: white Locking Ring 2NO HW2B-M220➀ 0.8 to 6 Y: yellow 2NC HW2B-M202➀ 2NO-2NC HW2B-M222➀ 1NO HW2B-A210➀ 1NC HW2B-A201➀ 1NO-1NC HW2B-A211➀ 13 29.4 Maintained 49.4 (1 or 2 blocks) 19 2NO HW2B-A220➀ 69.4 (4 blocks) 2NC HW2B-A202➀ 2NO-2NC HW2B-A222➀ • Pushbuttons with one or three contact blocks contain a dummy block. • Other contact arrangements and gold-plated silver contacts are also available. See page 7. Contact Block (Bottom View) Terminal Wiring • Arrows indicate access directions for wiring. 1 contact block 2 contact blocks 4 contact blocks 16 24.8 25 25 29.6 29.6 41.4 41.4 LOCK LOCK LOCK ����� ������ �������� ���������� ���� ������ HW Series Pushbuttons ø22 Round Button with Square Bezel Type Operation ➀ Button Shape Contact Type No. Dimensions (mm) Type Color Code Round Flush 1NO HW3B-M110➀ with Square Bezel 1NC HW3B-M101➀ HW3B-M1 M3.5 Terminal 1NO-1NC HW3B-M111➀ Screw Momentary HW3B-A1 Panel Thickness 2NO HW3B-M120➀ Locking Ring 0.8 to 6 2NC HW3B-M102➀ 2NO-2NC HW3B-M122➀ 1NO HW3B-A110➀ 1NC HW3B-A101➀ 1NO-1NC HW3B-A111➀ Maintained 49.4 (1 or 2 blocks) 13 29.4 2NO HW3B-A120➀ 69.4 (4 blocks) 2NC HW3B-A102➀ 2NO-2NC HW3B-A122➀ Round Extended 1NO HW3B-M210➀ with Square Bezel 1NC HW3B-M201➀ Specify a but- M3.5 Terminal HW3B-M2 1NO-1NC HW3B-M211➀ Screw ton color code Momentary HW3B-A2 Panel Thickness in place of ➀ in 2NO HW3B-M220➀ Locking Ring 0.8 to 6 the Type No. 2NC HW3B-M202➀ 2NO-2NC HW3B-M222➀ B: black 1NO HW3B-A210➀ G: green 1NC HW3B-A201➀ R: red 1NO-1NC HW3B-A211➀ S: blue 13 Maintained 29.4 W: white 2NO HW3B-A220➀ 49.4 (1 or 2 blocks) 19 Y: yellow 69.4 (4 blocks) 2NC HW3B-A202➀ 2NO-2NC HW3B-A222➀ ø29mm Mushroom 1NO HW3B-M310➀ with Square Bezel 1NC HW3B-M301➀ M3.5 Terminal HW3B-M3 Screw 1NO-1NC HW3B-M311➀ Momentary HW3B-A3 Panel Thickness 2NO HW3B-M320➀ Locking Ring 0.8 to 6 2NC HW3B-M302➀ 2NO-2NC HW3B-M322➀ 1NO HW3B-A310➀ 1NC HW3B-A301➀ 1NO-1NC HW3B-A311➀ 13 Maintained 29.4 49.4 (1 or 2 blocks) 2NO HW3B-A320➀ 23.2 69.4 (4 blocks) 2NC HW3B-A302➀ 2NO-2NC HW3B-A322➀ • Pushbuttons with one or three contact blocks contain a dummy block. • Other contact arrangements and gold-plated silver contacts are also available. See page 7. Contact Block (Bottom View) Terminal Wiring • Arrows indicate access directions for wiring. 1 contact block 2 contact blocks 4 contact blocks 17 ø23.6 ø23.6 ø29 25 25 25 29.6 29.6 29.6 41.4 41.4 41.4 X1 X1 X2 X2 ����� ���� �� ���������������� ������ ������ ø22 HW Series Pilot Lights Round Flush / Dome / Square Flush Types Shape Lamp Input Type Type No. ➁ Lens/LED Color Code ➂ Operating Voltage Code Round Flush A: amber Without Lamp Full Voltage HW1P-1Q0➁ HW1P-1 G: green PW: pure white Transformer HW1P-1➂2➁ R: red S: blue LED W: white DC-DC Converter∗ HW1P-1D2➁ Y: yellow A: amber G: green (Photo: Full Voltage Type) Incandescent Transformer HW1P-1➂5➁ R: red S: blue W: white Dome A: amber Without Lamp Full Voltage HW1P-2Q0➁ Specify an operating volt- HW1P-2 G: green age code in place of ➂ in PW: pure white the Type No. Transformer HW1P-2➂2➁ R: red S: blue LED H: 100/110V AC W: white DC-DC Converter∗ HW1P-2D2➁ H2: 115/120V AC Y: yellow M: 200/220V AC A: amber M4: 230/240V AC G: green S: 380V AC (Photo: Full Voltage Type) Incandescent Transformer HW1P-2➂5➁ R: red T: 400/440V AC S: blue T8: 480V AC W: white Square Flush A: amber Without Lamp Full Voltage HW2P-1Q0➁ HW2P-1 G: green PW: pure white Transformer HW2P-1➂2➁ R: red S: blue LED W: white DC-DC Converter∗ HW2P-1D2➁ Y: yellow A: amber G: green (Photo: Transformer Type) Incandescent Transformer HW2P-1➂5➁ R: red S: blue W: white • Specify a lens/LED color code in place of ➁ in the Type No. • Specify an operating voltage code in place of ➂ in the Type No. • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. • LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). Dimensions Mounting Hole Layout • • • • Full Voltage Type • Close mounting on 30mm centers Panel Thickness 0.8 to 6 Degree of protection: IP65 Gasket Flush Dome Roound/Dome Square Flush M3.5 Terminal Screw Locking Ring X2 X1 0.5 29.6 17.5 43.3 7 • • • • Transformer Type Flush Dome Round/Dome Square Flush M3.5 Terminal Screw 30 min. • When mounting transformer or DC-DC converter type units on 30mm centers vertically and horizontally, keep the 60.8 7 17.5 29.6 29.6 ambient temperature below 40°C. • • • • DC-DC Converter Type Flush Dome Round/Dome Square Flush M3.5 Terminal Screw All dimensions in mm. 29.6 29.6 76.2 7 17.5 18 +0.4 ø22.3 0 ø29 ø29 ø29 24 24 30 min. ������ ������ ���������������� ������ ������ HW Series Illuminated Pushbuttons ø22 Round Flush Illuminated Pushbutton Shape Operation Type Lamp Input Type Contact Type No. Round Flush 1NO HW1L-M110Q0➁ HW1L-M1 1NC HW1L-M101Q0➁ HW1L-A1 1NO-1NC HW1L-M111Q0➁ Without Lamp Full Voltage 2NO HW1L-M120Q0➁ 2NC HW1L-M102Q0➁ 2NO-2NC HW1L-M122Q0➁ 1NO-1NC HW1L-M111➂2➁ 2NO HW1L-M120➂2➁ Transformer 2NC HW1L-M102➂2➁ Momentary 2NO-2NC HW1L-M122➂2➁ LED 1NO-1NC HW1L-M111D2➁ 2NO HW1L-M120D2➁ DC-DC Converter∗ 2NC HW1L-M102D2➁ 2NO-2NC HW1L-M122D2➁ 1NO-1NC HW1L-M111➂5➁ 2NO HW1L-M120➂5➁ Incandescent Transformer 2NC HW1L-M102➂5➁ 2NO-2NC HW1L-M122➂5➁ 1NO HW1L-A110Q0➁ 1NC HW1L-A101Q0➁ 1NO-1NC HW1L-A111Q0➁ Without Lamp Full Voltage 2NO HW1L-A120Q0➁ 2NC HW1L-A102Q0➁ 2NO-2NC HW1L-A122Q0➁ 1NO-1NC HW1L-A111➂2➁ 2NO HW1L-A120➂2➁ Transformer 2NC HW1L-A102➂2➁ Maintained 2NO-2NC HW1L-A122➂2➁ LED 1NO-1NC HW1L-A111D2➁ 2NO HW1L-A120D2➁ DC-DC Converter∗ 2NC HW1L-A102D2➁ 2NO-2NC HW1L-A122D2➁ 1NO-1NC HW1L-A111➂5➁ 2NO HW1L-A120➂5➁ Incandescent Transformer 2NC HW1L-A102➂5➁ 2NO-2NC HW1L-A122➂5➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC PW: pure white R: red M: 200/220V AC R: red S: blue M4: 230/240V AC S: blue W: white S: 380V AC W: white T: 400/440V AC Y: yellow T8: 480V AC Note: Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 19 ������ ������ ���������������� ������ ������ ø22 HW Series Illuminated Pushbuttons Round Extended Illuminated Pushbutton Shape Operation Type Lamp Input Type Contact Type No. Round Extended 1NO HW1L-M210Q0➁ HW1L-M2 1NC HW1L-M201Q0➁ HW1L-A2 1NO-1NC HW1L-M211Q0➁ Without Lamp Full Voltage 2NO HW1L-M220Q0➁ 2NC HW1L-M202Q0➁ 2NO-2NC HW1L-M222Q0➁ 1NO-1NC HW1L-M211➂2➁ 2NO HW1L-M220➂2➁ Transformer 2NC HW1L-M202➂2➁ Momentary 2NO-2NC HW1L-M222➂2➁ LED 1NO-1NC HW1L-M211D2➁ 2NO HW1L-M220D2➁ DC-DC Converter∗ 2NC HW1L-M202D2➁ 2NO-2NC HW1L-M222D2➁ 1NO-1NC HW1L-M211➂5➁ 2NO HW1L-M220➂5➁ Incandescent Transformer 2NC HW1L-M202➂5➁ 2NO-2NC HW1L-M222➂5➁ 1NO HW1L-A210Q0➁ 1NC HW1L-A201Q0➁ 1NO-1NC HW1L-A211Q0➁ Without Lamp Full Voltage 2NO HW1L-A220Q0➁ 2NC HW1L-A202Q0➁ 2NO-2NC HW1L-A222Q0➁ 1NO-1NC HW1L-A211➂2➁ 2NO HW1L-A220➂2➁ Transformer 2NC HW1L-A202➂2➁ Maintained 2NO-2NC HW1L-A222➂2➁ LED 1NO-1NC HW1L-A211D2➁ 2NO HW1L-A220D2➁ DC-DC Converter∗ 2NC HW1L-A202D2➁ 2NO-2NC HW1L-A222D2➁ 1NO-1NC HW1L-A211➂5➁ 2NO HW1L-A220➂5➁ Incandescent Transformer 2NC HW1L-A202➂5➁ 2NO-2NC HW1L-A222➂5➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC PW: pure white R: red M: 200/220V AC R: red S: blue M4: 230/240V AC S: blue W: white S: 380V AC W: white T: 400/440V AC Y: yellow T8: 480V AC Note: Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 20 ������ ������ ���������������� ������ ������ HW Series Illuminated Pushbuttons ø22 Round Extended with Full Shroud Illuminated Pushbutton Shape Operation Type Lamp Input Type Contact Type No. Round Extended 1NO HW1L-MF210Q0➁ with Full Shroud 1NC HW1L-MF201Q0➁ HW1L-MF2 1NO-1NC HW1L-MF211Q0➁ HW1L-AF2 Without Lamp Full Voltage 2NO HW1L-MF220Q0➁ 2NC HW1L-MF202Q0➁ 2NO-2NC HW1L-MF222Q0➁ 1NO-1NC HW1L-MF211➂2➁ 2NO HW1L-MF220➂2➁ Transformer 2NC HW1L-MF202➂2➁ Momentary 2NO-2NC HW1L-MF222➂2➁ LED 1NO-1NC HW1L-MF211D2➁ 2NO HW1L-MF220D2➁ DC-DC Converter∗ 2NC HW1L-MF202D2➁ 2NO-2NC HW1L-MF222D2➁ 1NO-1NC HW1L-MF211➂5➁ 2NO HW1L-MF220➂5➁ Incandescent Transformer 2NC HW1L-MF202➂5➁ 2NO-2NC HW1L-MF222➂5➁ 1NO HW1L-AF210Q0➁ 1NC HW1L-AF201Q0➁ 1NO-1NC HW1L-AF211Q0➁ Without Lamp Full Voltage 2NO HW1L-AF220Q0➁ 2NC HW1L-AF202Q0➁ 2NO-2NC HW1L-AF222Q0➁ 1NO-1NC HW1L-AF211➂2➁ 2NO HW1L-AF220➂2➁ Transformer 2NC HW1L-AF202➂2➁ Maintained 2NO-2NC HW1L-AF222➂2➁ LED 1NO-1NC HW1L-AF211D2➁ 2NO HW1L-AF220D2➁ DC-DC Converter∗ 2NC HW1L-AF202D2➁ 2NO-2NC HW1L-AF222D2➁ 1NO-1NC HW1L-AF211➂5➁ 2NO HW1L-AF220➂5➁ Incandescent Transformer 2NC HW1L-AF202➂5➁ 2NO-2NC HW1L-AF222➂5➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC PW: pure white R: red M: 200/220V AC R: red S: blue M4: 230/240V AC S: blue W: white S: 380V AC W: white T: 400/440V AC Y: yellow T8: 480V AC Note: Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 21 ������ ������ ���������������� ������ ������ ø22 HW Series Illuminated Pushbuttons Square Flush Illuminated Pushbutton Shape Operation Type Lamp Input Type Contact Type No. Square Flush 1NO HW2L-M110Q0➁ HW2L-M1 1NC HW2L-M101Q0➁ HW2L-A1 1NO-1NC HW2L-M111Q0➁ Without Lamp Full Voltage 2NO HW2L-M120Q0➁ 2NC HW2L-M102Q0➁ 2NO-2NC HW2L-M122Q0➁ 1NO-1NC HW2L-M111➂2➁ 2NO HW2L-M120➂2➁ Transformer 2NC HW2L-M102➂2➁ Momentary 2NO-2NC HW2L-M122➂2➁ LED 1NO-1NC HW2L-M111D2➁ 2NO HW2L-M120D2➁ DC-DC Converter∗ 2NC HW2L-M102D2➁ 2NO-2NC HW2L-M122D2➁ 1NO-1NC HW2L-M111➂5➁ 2NO HW2L-M120➂5➁ Incandescent Transformer 2NC HW2L-M102➂5➁ 2NO-2NC HW2L-M122➂5➁ 1NO HW2L-A110Q0➁ 1NC HW2L-A101Q0➁ 1NO-1NC HW2L-A111Q0➁ Without Lamp Full Voltage 2NO HW2L-A120Q0➁ 2NC HW2L-A102Q0➁ 2NO-2NC HW2L-A122Q0➁ 1NO-1NC HW2L-A111➂2➁ 2NO HW2L-A120➂2➁ Transformer 2NC HW2L-A102➂2➁ Maintained 2NO-2NC HW2L-A122➂2➁ LED 1NO-1NC HW2L-A111D2➁ 2NO HW2L-A120D2➁ DC-DC Converter∗ 2NC HW2L-A102D2➁ 2NO-2NC HW2L-A122D2➁ 1NO-1NC HW2L-A111➂5➁ 2NO HW2L-A120➂5➁ Incandescent Transformer 2NC HW2L-A102➂5➁ 2NO-2NC HW2L-A122➂5➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC PW: pure white R: red M: 200/220V AC R: red S: blue M4: 230/240V AC S: blue W: white S: 380V AC W: white T: 400/440V AC Y: yellow T8: 480V AC Note: Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 22 ������ ������ ���������������� ������ ������ HW Series Illuminated Pushbuttons ø22 Round Flush with Square Bezel Illuminated Pushbutton Shape Operation Type Lamp Input Type Contact Type No. Round Flush 1NO HW3L-M110Q0➁ with Square Bezel 1NC HW3L-M101Q0➁ HW3L-M1 1NO-1NC HW3L-M111Q0➁ HW3L-A1 Without Lamp Full Voltage 2NO HW3L-M120Q0➁ 2NC HW3L-M102Q0➁ 2NO-2NC HW3L-M122Q0➁ 1NO-1NC HW3L-M111➂2➁ 2NO HW3L-M120➂2➁ Transformer 2NC HW3L-M102➂2➁ Momentary 2NO-2NC HW3L-M122➂2➁ LED 1NO-1NC HW3L-M111D2➁ 2NO HW3L-M120D2➁ DC-DC Converter∗ 2NC HW3L-M102D2➁ 2NO-2NC HW3L-M122D2➁ 1NO-1NC HW3L-M111➂5➁ 2NO HW3L-M120➂5➁ Incandescent Transformer 2NC HW3L-M102➂5➁ 2NO-2NC HW3L-M122➂5➁ 1NO HW3L-A110Q0➁ 1NC HW3L-A101Q0➁ 1NO-1NC HW3L-A111Q0➁ Without Lamp Full Voltage 2NO HW3L-A120Q0➁ 2NC HW3L-A102Q0➁ 2NO-2NC HW3L-A122Q0➁ 1NO-1NC HW3L-A111➂2➁ 2NO HW3L-A120➂2➁ Transformer 2NC HW3L-A102➂2➁ Maintained 2NO-2NC HW3L-A122➂2➁ LED 1NO-1NC HW3L-A111D2➁ 2NO HW3L-A120D2➁ DC-DC Converter∗ 2NC HW3L-A102D2➁ 2NO-2NC HW3L-A122D2➁ 1NO-1NC HW3L-A111➂5➁ 2NO HW3L-A120➂5➁ Incandescent Transformer 2NC HW3L-A102➂5➁ 2NO-2NC HW3L-A122➂5➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC PW: pure white R: red M: 200/220V AC R: red S: blue M4: 230/240V AC S: blue W: white S: 380V AC W: white T: 400/440V AC Y: yellow T8: 480V AC Note: Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 23 ������ ������ ���������������� ������ ������ ø22 HW Series Illuminated Pushbuttons Mushroom (ø29mm) Illuminated Pushbutton Shape Operation Type Lamp Input Type Contact Type No. ø29mm Mushroom 1NO HW1L-M310Q0➁ HW1L-M3 1NC HW1L-M301Q0➁ HW1L-A3 1NO-1NC HW1L-M311Q0➁ Without Lamp Full Voltage 2NO HW1L-M320Q0➁ 2NC HW1L-M302Q0➁ 2NO-2NC HW1L-M322Q0➁ 1NO-1NC HW1L-M311➂2➁ 2NO HW1L-M320➂2➁ Transformer 2NC HW1L-M302➂2➁ Momentary 2NO-2NC HW1L-M322➂2➁ LED 1NO-1NC HW1L-M311D2➁ 2NO HW1L-M320D2➁ DC-DC Converter∗ 2NC HW1L-M302D2➁ 2NO-2NC HW1L-M322D2➁ 1NO-1NC HW1L-M311➂5➁ 2NO HW1L-M320➂5➁ Incandescent Transformer 2NC HW1L-M302➂5➁ 2NO-2NC HW1L-M322➂5➁ 1NO HW1L-A310Q0➁ 1NC HW1L-A301Q0➁ 1NO-1NC HW1L-A311Q0➁ Without Lamp Full Voltage 2NO HW1L-A320Q0➁ 2NC HW1L-A302Q0➁ 2NO-2NC HW1L-A322Q0➁ 1NO-1NC HW1L-A311➂2➁ 2NO HW1L-A320➂2➁ Transformer 2NC HW1L-A302➂2➁ Maintained 2NO-2NC HW1L-A322➂2➁ LED 1NO-1NC HW1L-A311D2➁ 2NO HW1L-A320D2➁ DC-DC Converter∗ 2NC HW1L-A302D2➁ 2NO-2NC HW1L-A322D2➁ 1NO-1NC HW1L-A311➂5➁ 2NO HW1L-A320➂5➁ Incandescent Transformer 2NC HW1L-A302➂5➁ 2NO-2NC HW1L-A322➂5➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC PW: pure white R: red M: 200/220V AC R: red S: blue M4: 230/240V AC S: blue W: white S: 380V AC W: white T: 400/440V AC Y: yellow T8: 480V AC Note: Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 24 ������ ������ ���������� ��������������� ������ HW Series Illuminated Pushbuttons ø22 Mushroom (ø29mm) with Square Bezel Illuminated Pushbutton Shape Operation Type Lamp Input Type Contact Type No. ø29mm Mushroom 1NO HW3L-M310Q0➁ with Square Bezel 1NC HW3L-M301Q0➁ HW3L-M3 1NO-1NC HW3L-M311Q0➁ HW3L-A3 Without Lamp Full Voltage 2NO HW3L-M320Q0➁ 2NC HW3L-M302Q0➁ 2NO-2NC HW3L-M322Q0➁ 1NO-1NC HW3L-M311➂2➁ 2NO HW3L-M320➂2➁ Transformer 2NC HW3L-M302➂2➁ Momentary 2NO-2NC HW3L-M322➂2➁ LED 1NO-1NC HW3L-M311D2➁ 2NO HW3L-M320D2➁ DC-DC Converter∗ 2NC HW3L-M302D2➁ 2NO-2NC HW3L-M322D2➁ 1NO-1NC HW3L-M311➂5➁ 2NO HW3L-M320➂5➁ Incandescent Transformer 2NC HW3L-M302➂5➁ 2NO-2NC HW3L-M322➂5➁ 1NO HW3L-A310Q0➁ 1NC HW3L-A301Q0➁ 1NO-1NC HW3L-A311Q0➁ Without Lamp Full Voltage 2NO HW3L-A320Q0➁ 2NC HW3L-A302Q0➁ 2NO-2NC HW3L-A322Q0➁ 1NO-1NC HW3L-A311➂2➁ 2NO HW3L-A320➂2➁ Transformer 2NC HW3L-A302➂2➁ Maintained 2NO-2NC HW3L-A322➂2➁ LED 1NO-1NC HW3L-A311D2➁ 2NO HW3L-A320D2➁ DC-DC Converter∗ 2NC HW3L-A302D2➁ 2NO-2NC HW3L-A322D2➁ 1NO-1NC HW3L-A311➂5➁ 2NO HW3L-A320➂5➁ Incandescent Transformer 2NC HW3L-A302➂5➁ 2NO-2NC HW3L-A322➂5➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC PW: pure white R: red M: 200/220V AC R: red S: blue M4: 230/240V AC S: blue W: white S: 380V AC W: white T: 400/440V AC Y: yellow T8: 480V AC Note: Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 25 ������ ������ ���������������� ������ ������ ø22 HW Series Illuminated Pushbuttons Mushroom (ø40mm) Illuminated Pushbutton Shape Operation Type Lamp Input Type Contact Type No. ø40mm Mushroom 1NO HW1L-M410Q0➁ HW1L-M4 1NC HW1L-M401Q0➁ HW1L-A4 1NO-1NC HW1L-M411Q0➁ Without Lamp Full Voltage 2NO HW1L-M420Q0➁ 2NC HW1L-M402Q0➁ 2NO-2NC HW1L-M422Q0➁ 1NO-1NC HW1L-M411➂2➁ 2NO HW1L-M420➂2➁ Transformer 2NC HW1L-M402➂2➁ Momentary 2NO-2NC HW1L-M422➂2➁ LED 1NO-1NC HW1L-M411D2➁ 2NO HW1L-M420D2➁ DC-DC Converter∗ 2NC HW1L-M402D2➁ 2NO-2NC HW1L-M422D2➁ 1NO-1NC HW1L-M411➂5➁ 2NO HW1L-M420➂5➁ Incandescent Transformer 2NC HW1L-M402➂5➁ 2NO-2NC HW1L-M422➂5➁ 1NO HW1L-A410Q0➁ 1NC HW1L-A401Q0➁ 1NO-1NC HW1L-A411Q0➁ Without Lamp Full Voltage 2NO HW1L-A420Q0➁ 2NC HW1L-A402Q0➁ 2NO-2NC HW1L-A422Q0➁ 1NO-1NC HW1L-A411➂2➁ 2NO HW1L-A420➂2➁ Transformer 2NC HW1L-A402➂2➁ Maintained 2NO-2NC HW1L-A422➂2➁ LED 1NO-1NC HW1L-A411D2➁ 2NO HW1L-A420D2➁ DC-DC Converter∗ 2NC HW1L-A402D2➁ 2NO-2NC HW1L-A422D2➁ 1NO-1NC HW1L-A411➂5➁ 2NO HW1L-A420➂5➁ Incandescent Transformer 2NC HW1L-A402➂5➁ 2NO-2NC HW1L-A422➂5➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC PW: pure white R: red M: 200/220V AC R: red S: blue M4: 230/240V AC S: blue W: white S: 380V AC W: white T: 400/440V AC Y: yellow T8: 480V AC Note: Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 26 X1 X2 LOCK LOCK LOCK LOCK LOCK LOCK LOCK ������ ����� ���������������������� ������ HW Series Illuminated Pushbuttons ø22 Dimensions • Operator • Full Voltage Type Full Voltage Adapter Round with 1 contact block Square Bezel Round Square Panel Thickness 0.8 to 6 M3.5 Terminal Screw Contact Block Locking Ring Panel Thickness 0.8 to 6 13 24.8 29.4 29.4 29.4 49.4 (1 block) 1 contact block Full Voltage Adapter 2 contact blocks Extended 13 29.4 18.5 M3.5 Terminal Screw Contact Block Locking Ring Panel Thickness 0.8 to 6 Extended with Full Shroud 69.4 (2 blocks) 2 contact blocks 29.4 18.5 Full Voltage Adapter 3 contact blocks M3.5 Terminal Screw Mushroom (ø29) Contact Block Locking Ring Panel Thickness 0.8 to 6 13 29.4 23.2 69.4 (3 blocks) 3 contact blocks Mushroom (ø40) Full Voltage Adapter 4 contact blocks 13 29.4 23.2 M3.5 Terminal Screw Contact Block Locking Ring Panel Thickness 0.8 to 6 Terminal Wiring • Arrows indicate access directions for wiring. 4 contact blocks 89.4 (4 contacts) • Transformer Type X1 X2 X1 X2 79.5 (2 blocks) ( M3.5 Terminal Screws 99.5 4 blocks) Contact Block Transformer Full Voltage Adapter • DC-DC Converter Type Safety Lever Lock Locking Ring X1 X2 89.5 (2 blocks) 109.5 (4 blocks) M3.5 Terminal Screw 27 ø23.6 ø23.6 ø23.6 ø23.6 ø23.5 ø29.5 ø40 ø29 25 25 25 25 25 41.4 41.4 41.4 41.4 41.4 25 29.6 41.4 25 29.6 41.4 34 ����� ������ �������� �������������� ������ ø22 HW Series Selector Switches Selector Switches Shape HW1S Dimensions on page 32. Contact Arrangement Chart Maintained (90°) Spring Return from Contact Operator Position Right (60°) Contact Block —— LR Code L R Mounting Type LR Position NO 10 1 HW1S-2T10 HW1S-21T10 (1NO) Dummy 2 NO 11 1 HW1S-2T11 HW1S-21T11 (1NO-1NC) 2 NC NO 20 1 HW1S-2T20 HW1S-21T20 —— (2NO) 2 NO NO 1 22 2 NC HW1S-2T22 HW1S-21T22 NO (2NO-2NC) 3 4 NC Maintained Spring Return Spring Return Spring Return Contact Operator Position Contact from Right from Left Two-way Block C C C C Code L R L R L R L R Mounting Type LC R Position 1 NO 20 HW1S-3T20 HW1S-31T20 HW1S-32T20 HW1S-33T20 (2NO) 2 NO 1 NC 02 HW1S-3T02 HW1S-31T02 HW1S-32T02 HW1S-33T02 (2NC) 2 NC 1 NO 22N1 2 NO HW1S-3T22N1 HW1S-31T22N1 HW1S-32T22N1 HW1S-33T22N1 (2NO-2NC) 3 NC 4 NC 1 NC 22N9 ★ 2 NC HW1S-3ST22N9 — — — (2NO-2NC) 3 NO 4 NO 1 NO 40 2 NO HW1S-3T40 HW1S-31T40 HW1S-32T40 HW1S-33T40 (4NO) 3 NO 4 NO 1 NO 40N2 ★ 2 NO HW1S-3ST40N2 — — — (4NO) 3 NO 4 NO 1 NC 04 2 NC HW1S-3T04 HW1S-31T04 HW1S-32T04 HW1S-33T04 (4NC) 3 NC 4 NC 1 NO 21N1 ★ 2 NO HW1S-3JT21N1 — — — (2NO-1NC) 3 NC Dummy 4 Maintained Maintained Contact Operator Position • Contact Block Mounting Position Contact Block 2 3 2 4 1 3 and Contact Arrangement Chart Code 1 5 Mounting Type 12345 4 Position 4 2 1 NC 13N6 ★ 2 NC HW1S-4T13N6 — (1NO-3NC) 3 NC 4 NO 1 NO 3 22N3 ★ 2 NC 1 HW1S-4T22N3 — (2NO-2NC) 3 NC Center Left Right 4 NO 1 NO 12 ★ 2 NC LC R Operator HW1S-4T12 — (1NO-2NC) 3 NC Position 1 NO Dummy 4 2 NO 1 NO 22N3 ★ 2 NC 3 NC — HW1S-5T22N3 (2NO-2NC) 3 NC 4 NC 4 NO • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated cur- rent of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. • Selector switches with one or three contact blocks contain a dummy block. Knob operator: White indicator on black body • Other contact arrangements are also available. See pages 33 through 36. 28 30° 5-position / 45° 4-position 45° 3-position 90° 2-position / 60° 2-position No. of Positions ����� ������ �������� �������������� ������ HW Series Key Selector Switches ø22 Key Selector Switches Shape HW1K Dimensions on page 32. Contact Arrangement Chart Maintained (90°) Spring Return from Contact Operator Position Right (60°) Contact Block —— LR Code L R Mounting Type LR Position NO 10 1 HW1K-2A10 HW1K-21B10 (1NO) Dummy 2 NO 11 1 HW1K-2A11 HW1K-21B11 (1NO-1NC) 2 NC NO 20 1 HW1K-2A20 HW1K-21B20 —— (2NO) 2 NO NO 1 22 2 NC HW1K-2A22 HW1K-21B22 NO (2NO-2NC) 3 4 NC Maintained Spring Return Spring Return Spring Return Contact Operator Position Contact from Right from Left Two-way Block C C C C Code L R L R L R L R Mounting Type LC R Position 1 NO 20 HW1K-3A20 HW1K-31B20 HW1K-32C20 HW1K-33D20 (2NO) 2 NO 1 NC 02 HW1K-3A02 HW1K-31B02 HW1K-32C02 HW1K-33D02 (2NC) 2 NC 1 NO 22N1 2 NO HW1K-3A22N1 HW1K-31B22N1 HW1K-32C22N1 HW1K-33D22N1 (2NO-2NC) 3 NC 4 NC 1 NC 22N9 ★ 2 NC HW1K-3SA22N9 — — — (2NO-2NC) 3 NO 4 NO 1 NO 40 2 NO HW1K-3A40 HW1K-31B40 HW1K-32C40 HW1K-33D40 (4NO) 3 NO 4 NO 1 NO 40N2 ★ 2 NO HW1K-3SA40N2 — — — (4NO) 3 NO 4 NO 1 NC 04 2 NC HW1K-3A04 HW1K-31B04 HW1K-32C04 HW1K-33D04 (4NC) 3 NC 4 NC 1 NO 21N1 ★ 2 NO HW1K-3JA21N1 — — — (2NO-1NC) 3 NC Dummy 4 • On the spring-returned types, the key can be released only from the maintained position. On the maintained types, the key can be released from every position. Key retained positions are also available. See page 8. • Each key selector switch is supplied with two identical keys. Three different keys are also available. See page 8. • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated cur- rent of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. • Key selector switches with one or three contact blocks contain a dummy block. • Cylinder cover: black, Cylinder: metal • Other contact arrangements are also available. See pages 33 through 36. • Contact Block Mounting Position and Contact Arrangement Chart Center Left Right 4 2 LC R Operator Position 1 NO 2 NO 3 3 NC 1 4 NC 29 45° 3-position 90° 2-position / 60° 2-position No. of Positions ����� ������ �������� �������������� ������ ø22 HW Series Illiminated Selector Switches Illuminated Selector Switches 90° 2-position / 60° 2-position Shape HW1F Dimensions on page 32. Contact Arrangement Chart Maintained (90°) Spring Return from Contact Operator Right (60°) Contact Block Position Lamp Input Type LR L R Code Mounting Type LR Position 1 NO Without Lamp Full Voltage HW1F-211Q0➁ HW1F-2111Q0➁ 11 2 NC LED Transformer HW1F-211➂2➁ HW1F-2111➂2➁ (1NO-1NC) Incandescent Transformer HW1F-211➂5➁ HW1F-2111➂5➁ 1 NO Without Lamp Full Voltage HW1F-220Q0➁ HW1F-2120Q0➁ 20 2 NO LED Transformer HW1F-220➂2➁ HW1F-2120➂2➁ (2NO) Incandescent Transformer HW1F-220➂5➁ HW1F-2120➂5➁ 1 NO Without Lamp Full Voltage HW1F-222Q0➁ HW1F-2122Q0➁ 2 NC 3 NO 22 LED Transformer HW1F-222➂2➁ HW1F-2122➂2➁ (2NO-2NC) 4 NC Incandescent Transformer HW1F-222➂5➁ HW1F-2122➂5➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC R: red R: red M: 200/220V AC S: blue S: blue M4: 230/240V AC W: white W: white S: 380V AC Y: yellow T: 400/440V AC T8: 480V AC • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. • LED illuminated transformer types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Contact Block Mounting Position and Contact Arrangement Chart Transformer Full Voltage Adapter 4 Left Right 2 4 2 LR Operator Position 1 NO 2 NC 3 3 3 NO 1 1 4 NC Full Voltage Type Transformer Type For more contact arrangement chart, see page 33. 30 ����� ������ �������� �������������� ������ HW Series Illiminated Selector Switches ø22 45° 3-position Maintained Spring Return Spring Return Spring Return Contact Operator Lamp from Right from Left Two-way Contact Block Position C C C C Code Input Type L R L R L R L R Mounting Type LC R Position Without Lamp 1 NO HW1F-320Q0➁ HW1F-3120Q0➁ HW1F-3220Q0➁ HW1F-3320Q0➁ Full Voltage 20 LED 2 NO HW1F-320➂2➁ HW1F-3120➂2➁ HW1F-3220➂2➁ HW1F-3320➂2➁ (2NO) Transformer Incandescent HW1F-320➂5➁ HW1F-3120➂5➁ HW1F-3220➂5➁ HW1F-3320➂5➁ Transformer Without Lamp 1 NC HW1F-302Q0➁ HW1F-3102Q0➁ HW1F-3202Q0➁ HW1F-3302Q0➁ Full Voltage 02 LED 2 NC HW1F-302➂2➁ HW1F-3102➂2➁ HW1F-3202➂2➁ HW1F-3302➂2➁ (2NC) Transformer Incandescent HW1F-302➂5➁ HW1F-3102➂5➁ HW1F-3202➂5➁ HW1F-3302➂5➁ Transformer 1 NO Without Lamp HW1F-322N1Q0➁ HW1F-3122N1Q0➁ HW1F-3222N1Q0➁ HW1F-3322N1Q0➁ Full Voltage 2 NO 3 NC 22N1 LED HW1F-322N1➂2➁ HW1F-3122N1➂2➁ HW1F-3222N1➂2➁ HW1F-3322N1➂2➁ (2NO-2NC) Transformer 4 NC Incandescent HW1F-322N1➂5➁ HW1F-3122N1➂5➁ HW1F-3222N1➂5➁ HW1F-3322N1➂5➁ Transformer 1 NO Without Lamp HW1F-340Q0➁ HW1F-3140Q0➁ HW1F-3240Q0➁ HW1F-3340Q0➁ Full Voltage 2 NO 3 NO 40 LED HW1F-340➂2➁ HW1F-3140➂2➁ HW1F-3240➂2➁ HW1F-3340➂2➁ (4NO) Transformer 4 NO Incandescent HW1F-340➂5➁ HW1F-3140➂5➁ HW1F-3240➂5➁ HW1F-3340➂5➁ Transformer 1 NC Without Lamp HW1F-304Q0➁ HW1F-3104Q0➁ HW1F-3204Q0➁ HW1F-3304Q0➁ Full Voltage 2 NC 3 NC LED 04 HW1F-304➂2➁ HW1F-3104➂2➁ HW1F-3204➂2➁ HW1F-3304➂2➁ (4NC) Transformer 4 NC Incandescent HW1F-304➂5➁ HW1F-3104➂5➁ HW1F-3204➂5➁ HW1F-3304➂5➁ Transformer • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code place of ➁ in the Type No. ➁ in the Type No. in place of ➂ in the Type No. A: amber A: amber H: 100/110V AC G: green G: green H2: 115/120V AC R: red R: red M: 200/220V AC S: blue S: blue M4: 230/240V AC W: white W: white S: 380V AC Y: yellow T: 400/440V AC T8: 480V AC • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 43. • LED illuminated transformer types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Contact Block Mounting Position and Contact Arrangement Chart Transformer Full Voltage Adapter 4 Center Left Right 2 4 2 LC R Operator Position 1 NO 2 NO 3 3 3 NC 1 1 4 NC Full Voltage Type Transformer Type For more contact arrangement chart, see page 33. 31 LO LO LOCK L K CK CK OC ����� ������ �������� �������������� ������ ø22 HW Series Selector Switches Dimensions: Selector Switches Panel Thickness 0.8 to 6 • Knob Operator M3.5 Terminal Screw Gasket Locking Ring ( ) 49.4 1 or 2 blocks 7 29.4 1 contact block 2 contact blocks 4 contact blocks ( 21 69.4 3 or 4 blocks) • Key Operator 13 29.4 30.5 Dimensions: Illuminated Selector Switches • Full Voltage Type M3.5 Terminal Screw ( ) 69.4 2 blocks 7 29.4 ( ) 89.4 4 blocks 21 • Transformer Type X1 X2 7 ( ) M.3.5 Terminal� 79.5 2 blocks 29.4 Screw ( ) 99.5 4 blocks 21 All dimensions in mm. Terminal Wiring • Arrows indicate access directions for wiring. X1 X2 Contact Block Transformer Full Voltage Adapter 32 ø29.4 ø29 ø29 ø29 25 25 ø28.8 17 25 25 41.4 41.4 41.4 41.4 34 ����� ������ �������� �������������� ������ HW Series Selector Switch Contact Arrangement Charts ø22 90° 2-position (Maintained) / 60° 2-position (Spring Return) Operator Operator Availability Position LR L R Contact Contact Block Remarks Code Mounting Type LC Position 1 NO 10 ×××××× —Standard (1NO) Dummy 2 1 NC 01 ×××× — × — (1NC) Dummy 2 1 NO 11 ×××××× —Standard (1NO-1NC) 2 NC 1 NC 11N1 ×××× — × — (1NO-1NC) 2 NO 1 NO 20 ×××××× —Standard (2NO) 2 NO 1 NC 02 ×××× — × — (2NC) 2 NC 1 NO 2 NO 22 ×××××× —Standard (2NO-2NC) 3 NC 4 NC 1 NC 2 NO 22N2 ×××× — × — (2NO-2NC) 3 NC 4 NO 1 NO 2 NO 22N1 ×××× — × — (2NO-2NC) 3 NC 4 NC 1 NC 2 NO 22N4 ×××× — × — (2NO-2NC) 3 NO 4 NC 1 NC 2 NO 31N1 ×××× — × — (3NO-1NC) 3 NO 4 NO 1 NO 2 NO 40 ×××× — × — (4NO) 3 NO 4 NO 1 NO 7S ★ ×××× — × — (1NO-1NC) 2 NC 1 NO 2 NC 8S ★ ×××× — × — (2NO-2NC) 3 NO 4 NC 1 NC 2 NO 22N7 ★ ×××× — × — (2NO-2NC) 3 NC 4 NO • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. Remarks: When ordering the contact arrangement indicated with “Standard” in the table above, specify the Type No. shown in the standard Type No. on preceding pages. For other contact arrangements, see page 36 to specify the Type No. and con- tact code. 33 Knob Key Illuminated Knob Key Illuminated Cam Code ����� ������ �������� �������������� ������ ø22 HW Series Selector Switch Contact Arrangement Charts 45° 3-position Operator Availability Operator C C C C Position L R L R L R L R Contact Contact Block Remarks Code Mounting Type LC R Position 1 NO 11 ×××××××××××× — (1NO-1NC) 2 NC 1 NC 11N1 ×××××××××××× — (1NO-1NC) 2 NO 1 NO 7S ★ ××× ————————— J (1NO-1NC) 2 NC 1 NC 11N1 ★ ××× ————————— J (1NO-1NC) 2 NO 1 NO 20 ×××××××××××× —Standard (2NO) 2 NO 1 NO 1S ★ ××× ————————— J (2NO) 2 NO 1 NC 2S ★ ××× ————————— J (2NC) 2 NC 1 NC 02 ×××××××××××× —Standard (2NC) 2 NC 1 NO 2 NO 22N1 ×××××××××××× —Standard (2NO-2NC) 3 NC 4 NC 1 NC 2 NO 22N2 ×××××××××××× — (2NO-2NC) 3 NC 4 NO 1 NO 2 NC 8S ★ ××× ————————— J (2NO-2NC) 3 NO 4 NC 1 NO 2 NC 22N8 ★ ××× ————————— J (2NO-2NC) 3 NC 4 NO 1 NC 2 NO 22N2 ★ ××× ————————— J (2NO-2NC) 3 NC 4 NO 1 NO 2 NC 31 ×××××××××××× — (3NO-1NC) 3 NO 4 NO 1 NC 2 NO 31N1 ×××××××××××× — (3NO-1NC) 3 NO 4 NO 1 NO 2 NC 13 ×××××××××××× — (1NO-3NC) 3 NC 4 NC 1 NC 2 NO 13N3 ★ ××× ————————— J (1NO-3NC) 3 NC 4 NC Remarks: When ordering the contact arrangement indicated with “Standard” in the table above, specify the Type No. shown in the standard Type No. on preceding pages. For other contact arrangements, see page 36 to specify the Type No. and contact code. 34 Knob Key Illuminated Knob Key Illuminated Knob Key Illuminated Knob Key Illuminated Cam Code ����� ������ �������� �������������� ������ HW Series Selector Switch Contact Arrangement Charts ø22 45° 3-position Operator Availability Operator C C C C Position L R L R L R L R Contact Contact Block Remarks Code Mounting Type LC R Position 1 NO 2 NO 40 ×××××××××××× — Standard (4NO) 3 NO 4 NO 1 NO 2 NO 40N1 ★ ××× ————————— J (4NO) 3 NO 4 NO 1 NC 2 NC 04 ×××××××××××× — Standard (4NC) 3 NC 4 NC 1 NC 2 NC 04N2 ★ ××× ————————— J (4NC) 3 NC 4 NC 1 NO 2 NC 22 ★ ××× ————————— J (2NO-2NC) 3 NO 4 NC 1 NO 2 NO 21N1 ★ ××× ————————— J Standard (2NO-1NC) 3 NC Dummy 4 1 NO 2 NO 40N2 ★ ××× ————————— S Standard (4NO) 3 NO 4 NO 1 NC 2 NC 22N9 ★ ××× ————————— S Standard (2NO-2NC) 3 NO 4 NO 1 NO 2 NC 31N4 ★ ××× ————————— J (3NO-1NC) 3 NO 4 NO 1 NO 2 NC 13N1 ★ ××× ————————— J (1NO-3NC) 3 NC 4 NC 1 NC 2 NO 22N5 ★ ××× ————————— J (2NO-2NC) 3 NC 4 NO 1 NO 2 NO 31N2 ★ ××× ————————— J (3NO-1NC) 3 NC 4 NO 1 NC 2 NC 13N2 ★ ××× ————————— J (1NO-3NC) 3 NC 4 NO Remarks: When ordering the contact arrangement indicated with “Standard” in the table above, specify the Type No. shown in the standard Type No. on preceding pages. For other contact arrangements, see page 36 to specify the Type No. and contact code. 35 Knob Key Illuminated Knob Key Illuminated Knob Key Illuminated Knob Key Illuminated Cam Code ����� ����� ���������������������������� ø22 HW Series Selector Switch Contact Arrangement Charts 45° 4-position Operator Operator Position Availability Contact 2 Contact Block 1 3 Remarks Code 4 Mounting Type 1234 Knob Position 1 NO 2 NC 12 ★ × —Standard (1NO-2NC) 3 NC Dummy 4 1 NC 2 NC 04N3 ★ × — (4NC) 3 NC 4 NC 1 NC 2 NC 13N6 ★ × —Standard (1NO-3NC) 3 NC 4 NO 1 NO 2 NC 13N5 ★ × — (1NO-3NC) 3 NC 4 NC 1 NO 2 NC 22N3 ★ × —Standard (2NO-2NC) 3 NC 4 NO 30° 5-position Operator Operator Position Availability Contact 3 Contact 2 4 Block Remarks 1 5 Code Mounting Type 12345 Knob Position 1 NO 2 NC 22N3 ★ × —Standard (2NO-2NC) 3 NC 4 NO • Contact Block Mounting Position and Contact Arrangement Chart Transformer Full Voltage Adapter 4 Center Left Right 4 2 4 2 2 LC R Operator Position 1 NO 2 NO 3 3 3 3 NC 1 1 1 4 NC Non-illuminated Selector Illuminated Selector Illuminated Selector Full Voltage Type Transformer Type Type No. Development • When cam code is not required • When cam code is required HW1S - 2 T 11 HW1K - 3 J A 22N2 Contact code (1NO-1NC) Contact code (2NO-2NC) “T” for knob operator Key removal option code 2-position Cam code (J, S, or none) 3-position 36 Cam Code Cam Code LOCK ����� ������ �������� �������������� ������ HW Series Pushbutton Selectors ø22 Pushbutton Selectors Contact Circuit Contact ➀ Button Color Block Shape Type No. Category Code Code Mounting Type Normal Depressed Normal Depressed Position HW1R 1 NO 11 HW1R-2A11➀ (1NO-1NC) 2 NC 1 NO 20 HW1R-2A20➀ (2NO) 2 NO A 1 NO 2 NC 22 HW1R-2A22➀ (2NO-2NC) 3 NO 4 NC 1 NO 20 HW1R-2D20➀ (2NO) 2 NO 1 NO Specify a button D 2 NO 22N1 color code in HW1R-2D22N1➀ (2NO-2NC) 3 NC place of ➀ in the Type No. 4 NC 1 NO B: black 2 NO 22N1 ★ G: green E HW1R-2E22N1➀ (2NO-2NC) 3 NC R: red 4 NC S: blue W: white 1 NO Y: yellow 2 NO 22N1 ★ F HW1R-2F22N1➀ (2NO-2NC) 3 NC 4 NC 1 NC 2 NO 22N2 ★ N HW1R-2N22N2➀ (2NO-2NC) 3 NC 4 NO 1 NO 2 NO 22N1 ★ T Blocked HW1R-2T22N1➀ (2NO-2NC) 3 NC 4 NC • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated cur- rent of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. • When operating the pushbutton selector, do not turn the operator ring or the lock lever while the button is depressed. Otherwise the push- button selector may be damaged. • Other contact arrangements are also available upon request. • Contact Block Mounting Position and Dimensions Contact Arrangement Chart Panel Thickness 0.8 to 6 M3.5 Terminal 4 Gasket Screw 2 Locking Ring 3 1 Ring Position Contact Left Right ( ) 49.4 2 blocks 29.4 Block Normal Depressed Normal Depressed ( ) 69.4 4 blocks 23.5 Button 1 NO 2 NO All dimensions in mm. 3 NC 4 NC 37 ø28 ø29.4 25 41.4 LOCK ����� ������ �������� �������������� ������ ø22 HW Series Mono-Lever Switches Mono-Lever Switches Shape Positions Type No. HW1M-1010-20 HW1M Standard Lever HW1M-2020-20 HW1M-0101-20 2-position HW1M-0202-20 HW1M-0101-40 HW1M-0202-40 HW1M-1111-22N9 4-position HW1M-2222-22N9 HW1M-L1010-20 HW1M-L Interlocking Lever HW1M-L2020-20 HW1M-L0101-20 2-position HW1M-L0202-20 HW1M-L0101-40 HW1M-L0202-40 HW1M-L1111-22N9 4-position HW1M-L2222-22N9 • On all mono-lever switches, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. Contact Arrangement Chart • 2-position (Right/Left) • 2-position (Up/Down) • 4-position Contact Lever Operator Contact Lever Operator Contact Lever Operator Position Block Position Block Position Block Contact Contact Contact Code Code Code Mounting Mounting Mounting Type Left Center Right Type Down Center Up Type Down Left Center Up Right Position Position Position 1 NO 1 NO 1 NC 20 20 2 NO 2 NO 2 NC 22N9 1 NO 1 NO 3 NO 2 NO 2 NO 4 NO 40 40 3 NO 3 NO 4 NO 4 NO Ordering Information • Contact Block Mounting Position and Up R Dn L Lever Operator Position HW1M-L — 111 1 — 22N9 4 2 Up Type Lever Operation Mode Contact Code HW1M: Standard Order of Entry Select a required contact HW1M-L: Interlocking Up → Right → Down → Left operation at each lever 1: Maintained operator position from 3 Right 2: Spring returned the contact arrangement Contact Block 1 0: Blocked charts above and specify Lever Operator Mounting Position Left the Contact Code. Position • The lever operator of the interlocking type HW1M-L is locked only in the center position. Down Dimensions M3.5 Terminal Locking Ring Panel Thickness 0.8 to 6 Screw 8 49.4 (2 blocks) 29.4 ( ) 69.4 4 blocks 72 45.5 All dimensions in mm. 38 ø34.2 24° 25 36 max. 36 max. 41.4 24° Y ø22 ø22 C N S E T G ������������ ������ ������������������ ���� ������ HW Series Accessories and Replacement Parts ø22 Accessories Nameplates • HWAM, HWAQ, HWAS, and HWAV Ordering Package Description Legend Material Type No. Dimensions (mm) Type No. Quantity Marking Plate 29 HWAM 1 27 2.7 Order marking plate Plastic (black) HWAM HWAM separately. 1.5 mm thick R14.9 HWAMPN10 10 1.5 1 Marking Plate 29 HWAQ 1 27 2.7 Order marking plate Plastic (black) HWAQ HWAQ separately. 1.5 mm thick R14.9 HWAQPN10 10 1.9 1 45 1.6 0.9 HWAS-0 1 Plastic (black) HWAS Blank HWAS-0 1.5 mm thick HWAS-0PN10 10 Blank HWAV-0 HWAV-0 1 Plastic (yellow) HWAV 1.5 mm thick 1.6 0.9 EMERGENCY STOP HWAV-27 HWAV-27 1 •Legend “Emergency Stop” is indicated outside a ø44mm circle. • Making Plate Description Material Type No. Ordering Type No. Package Quantity Dimensions (mm) • White legend on black background. HWNP-∗ 1 Aluminum (black) 27 HWNP HWNP-∗ 1.0 mm thick HWNP-∗PN10 10 • Specify a legend code in place of ∗ in the Ordering Type No. Legends Code Legend • Installing the marking plate • To remove the marking plate, insert the flat screwdriver beween 0(blank) on a nameplate the marking plate and nameplate. 1ON 2OFF 3START Nameplate Flat Screwdriver 4STOP ➁ Marking Plate 31 OFF-ON 35 HAND-AUTO When requring no anti-rotation, remove the projection using pliers. ➀ 53 HAND-OFF-AUTO Nameplate Note: When using an nameplate, the mounting panel thickness is decreased by 1.5 mm. 39 O R P E M ø22 ø60 ø22 E Marking Plate 30 30 12.1 12.1 12 14.5 14.9 14.5 14.9 ø19 ������������ ������ ������������������ ���� ������ ø22 HW Series Accessories and Replacement Parts Accessories Ordering Package Shape Material Type No. Dimensions (mm) Type No. Quantity • Used to tighten the locking ring when installing Locking Ring Wrench the HW switch onto a panel. • Tighten the locking ring to a torque of 2.0 N·m. Metal (weight: MW9Z-T1 MW9Z-T1 1 110 approx. 150g) Lamp Holder Tool • Used to install and remove the LED/incandes- cent lamps. Rubber OR-55 OR-55 1 59 • Used to remove the contact block and trans- Contact Block Removal Tool former, and also to install/remove the pilot light and illuminated pushbutton lens. Metal/Rubber TW-KC1 TW-KC1 1 130 Anti-rotation Ring • Used to prevent the operator from turning. Generally used when using no nameplates on selector switches and pushbutton selectors. 1.5 TOP Plastic HW9Z-RL HW9Z-RLPN10 10 Rubber Mounting Hole Plug • Used to plug the unused ø22.2mm mounting holes. ø29 Rubber (black) OB-31 OB-31PN05 5 ø25 Metallic Mounting Hole Plug • Used to plug the unused ø22.2mm mounting holes. • Tighten the locking ring to a torque of 1.2 N·m. Diecast Metal • IP66 (locking ring: LW9Z-BM LW9Z-BM 1 ø25.8 • Mounting panel thickness: plastic) 0.8 to 6 mm Gasket Locking Ring Barrier • Used to prevent con- tact between adjacent lead wires when units are mounted closely. Plastic HW-VG1 HW-VG1PN10 10 Barriers should always be used in close mounting. 20 1.5 • Used to prevent inadvertent operation for flush Switchguard pushbuttons and illuminated pushbuttons. • IP65 Spring HW9Z-K1 HW9Z-K1 1 • Maintained type stops at 90° and 180°. Return 49.4 31 min. Spring Return Panel Thickness: 0.8 to 5 Plastic Maintained HW9Z-K11 HW9Z-K11 1 0.4 17.4 48.3 40 ø22 R33.7 ø29 ø28 68 min. ø11.6 3.5 45 39 3.5 23 ø14 12 3 51.2 R66.5 ø22.2 ������������ ������ ������������������ ���� ������ HW Series Accessories and Replacement Parts ø22 Accessories Ordering Package Shape Material Type No. Dimensions (mm) Type No. Quantity Pushbutton • Used to cover and protect pushbuttons where units are For flush Clear Boot OC-31 OC-31 1 subject to watersplash. Not pushbuttons suitable for outdoor use or Rubber (EPDM) where the units are subject to oil splash. For extended OC-32 OC-32 1 pushbuttons ( ) 18 OC-31 ( ) 22 OC-32 • Used to protect pushbuttons, illuminated pushbut- Padlock cover tons, selector switches, and key selector switches. Panel Thickness 82.5 0.8 to 3.2 Polyarylate (gasket: nitryl HW9Z-KL1 HW9Z-KL1 1 rubber) 24 29.5 Key Hole ø8 Waterproof Rubber Gasket 0.5t 30 • Used to install the HW/TW units into ø25 Ring Adapter mounting holes. • IP65 HW9Z-A25 HW9Z-A25PN05 5 • Cannot be used with anti-rotation ring and nameplate. • Mounting panel thickness: 1.2 to 6.0 mm • Used to install the HW units into ø30 mounting Ring Adapter holes (except for HW1E and HW1B-M5/V5). • IP65 HW9Z-A30 HW9Z-A30PN02 2 • Cannot be used with anti-rotation ring, name- plate, full-shroud illuminated pushbuttons, pushbutton selectors, and mono-lever switches. • Mounting panel thickness:1.6 to 4.0 mm • Used to install the HW1E units into ø30 mount- Ring Adapter ing holes. • IP65 HW9Z-A30E HW9Z-A30EPN02 2 • Cannot be used with anti-rotation ring and nameplate. • Mounting panel thickness:1.6 to 3.8 mm Maintenance Parts Ordering Package Shape Specification Type No. Remarks Type No. Quantity Contact Block 1NO contact HW-G10 HW-G10 1 1NC contact HW-G01 HW-G01 1 EM (early make) contact HW-G10R HW-G10R 1 LB (late break) contact HW-G01R HW-G01R 1 Dummy Block TW-DB TW-DBPN10 10 Full Voltage Adapter HW-GA1 HW-GA1PN02 2 Transformer 100/110V AC HW-T16 HW-T16 1 • For illuminated pushbuttons and illumi- nated selector switches. 200/220V AC HW-T26 HW-T26 1 Dome Lens for Pilot Light • Specify a color code in place of ➁. AS resin HW1A-P2➁ HW1A-P2➁PN05 5 A (amber), G (green), R (red), S (blue), W (white), and Y (yellow) 41 ø50 (ID: ø44.4) 70 30 ø32.6 93 ������������ ������ ������������������ ���� ������ ø22 HW Series Accessories and Replacement Parts Maintenance Parts Package Shape Specification Type No. Ordering Type No. Color Code Quantity Button Round flush with HW1A-B1➀ HW1A-B1➀PN05 5 round or square bezel Round extended with HW1A-B2➀ HW1A-B2➀PN05 5 B (black) round or square bezel G (green) Square flush HW2A-B1➀ HW2A-B1➀PN05 5 R (red) Polyacetal S (blue) Square extended HW2A-B2➀ HW2A-B2➀PN05 5 W (white) Y (yellow) ø29mm mushroom HW1A-B3➀ HW1A-B3➀PN02 2 ø40mm mushroom HW1A-B4➀ HW1A-B4➀PN02 2 Lens (for pilot lights A (amber), C (clear), Round flush HW9Z-L11➁ HW9Z-L11➁PN05 5 G (green), R (red), S (blue), and illuminated Y (yellow) Square flush Polyarylate HW9Z-L21➁ HW9Z-L21➁PN05 5 pushbuttons) Note: Use a clear lens for Round extended HW9Z-L12➁ HW9Z-L12➁PN05 5 white illumination. Lens (for illuminated C (clear), G (green), ALW31L-➁ ALW31L-➁PN02 2 R (red), S (blue) pushbuttons) ø29mm mushroom A (amber), Y (yellow) ALW31LD-➁ ALW31LD-➁PN02 2 AS, Marking type C (clear), G (green), ALW41L-➁ ALW41L-➁ 1 R (red), S (blue) ø40mm mushroom A (amber), Y (yellow) ALW41LD-➁ ALW41LD-➁ 1 Marking Plate Round flush HW9Z-P11 HW9Z-P11PN05 5 Round extended HW9Z-P12 HW9Z-P12PN05 5 Acrylic • White Square flush HW9Z-P21 HW9Z-P21PN05 5 ø29/40mm mushroom ALW3B ALW3BPN05 5 Operator Knob for Illuminated Selector Switch A (amber) G (green) R (red) Polyarylate HW9Z-FDY➁ HW9Z-FDY➁ 1 S (blue) W (white) Y (yellow) Replacement key Key selector switch Metal HW9Z-SK-231 HW9Z-SK-231PN02 2 Locking Ring Plastic HW9Z-LN HW9Z-LNPN05 5 • Black Cap for Mono-Lever Switch HW9Z-CPM HW9Z-CPM 1 Standard Rubber Boot for Mono-Lever Switch HW9Z-BLM HW9Z-BLM 1 Safety Lever Lock • Yellow Plastic HW9Z-LS HW9Z-LSPN10 10 Note: Specify a button color code or lens color code in place of ➀ or ➁ in the Ordering Type No. 42 ������������ ������ ������������������ ���� ������ HW Series Accessories and Replacement Parts ø22 Maintenance Parts LED Lamps (LSTD Type) Current Draw Ordering Illumination Package Operating Voltage Type No. Base Type No. Color Code Quantity AC DC 6V AC/DC ±5% Specify a color code LSTD-6➁ 1 17 mA (A, R, W, Y) 14 mA (A, R, W, Y) in place of ➁ in the LSTD-6∗ Ordering Type No. 8 mA (G, PW, S) 5.5 mA (G, PW, S) LSTD-6➁PN10 10 A: amber 12V AC/DC ±10% G: green LSTD-1➁ 1 PW: pure white 11 mA 10 mA LSTD-1∗ BA9S/13 R: red LSTD-1➁PN10 10 S: blue 24V AC/DC ±10% W: white LSTD-2➁ 1 Y: yellow 11 mA 10 mA LSTD-2∗ LSTD-2➁PN10 10 Incandescent Lamps (LS Type) Rated Operating Voltage Lamp Ratings Type No. Package Quantity 6V AC/DC 1W (6.3V) LS-6 12V AC/DC 1W (18V) LS-8 1 18V AC/DC 1W (24V) LS-2 24V AC/DC 1W (30V) LS-3 Transformer Shape Primary Voltage Secondary Voltage Type No. Applicable Load Separate Mounting Type 100/110V AC TWR516 One full voltage type pilot light or illuminated switch containing 200/220V AC 5.5V TWR526 LSTD-6 LED lamp (6V AC/DC) or LS-6 incandescent lamp (6V AC/DC, 1W) 400/440V AC TWR546 43 LOCK ��������������� ������ ���������������������� ����� ø22 HW Series Instructions Safety Precautions • Turn off the power to the HW series control units before • For wiring, use wires of a proper size to meet the voltage starting installation, removal, wiring, maintenance, and and current requirements. Tighten the M3.5 terminal inspection of the products. Failure to turn power off may screws to a tightening torque of 1.0 to 1.3 N·m. Failure to cause electrical shocks or fire hazard. tighten terminal screws may cause overheat and fire. • To avoid a burn on your hand, use the lamp holder tool when replacing lamps. Instructions • Notes for Panel Mounting Panel Mounting 1. When mounting the operator onto a panel, use the Remove the contact block from the operator (for transformer optional locking ring wrench (MW9Z-T1) to tighten the type pilot lights, remove the transformer from the illumina- locking ring. Tightening torque must not exceed 2.0 N·m. tion unit). Remove the locking ring from the operator. Insert Do not use pliers. Excessive tightening will damage the the operator into the panel cut-out from the front, tighten the locking ring. locking ring from the back, then install the contact block to 2. For the contact blocks and transformers housing LED the operator. and incandescent lamps, make sure not to press the • Removing and Installing the Contact Block lamps too hard, otherwise the lamp socket may be 1. To remove the operator from the contact block, turn the impaired. locking lever in the direction of the arrow shown below. • Notes for Illuminated Pushbuttons Then the operator can be pulled out. The full shroud cannot be removed from the extended full 2. To reinstall, place the TOP markings on the operator and shroud type. the contact block mounting adapter in the same direction, and insert the operator into the contact block mounting Safety Lever Lock adapter. Then turn the locking lever in the opposite direc- IDEC strongly recommends using the safety lever lock tion. (HW9Z-LS, yellow) to prevent heavy vibration or mainte- nance personnel from unlocking contacts. 1. HW series can be mounted vertically with a minimum spacing of 50 mm (70 mm for mono-lever switches) but spacing should be determined to ensure easy operation. 2. Mount the control unit onto the panel, lock the lever, and strongly push in the safety lever lock to install. 3. When the spacing is narrower than the recommended value, with the lever unlocked, mount the safety lever lock and insert the contact unit to the operator. Then, lock the • Removing and Installing the Transformer Unit on Pilot lever and strongly push in the safety lever lock to install. Lights 4. To remove the safety lever lock, insert a flat screwdriver 1. Insert a flat screwdriver (5mm wide at the maximum) into into the safety lever lock and push upwards. the latch hole on the transformer unit as shown in the photo below, and disengage the latch. Then pull out the illumination unit. Safety Lever Lock 2. To reinstall, place the TOP marking on the illumination Lock Lever unit and the latch in the same direction, and push the illu- mination unit into the transformer unit. Safety Lever Lock Screwdriver Remove Operator Contact Block Panel Mounting Adapter 44 26.5 Install ��������������� �����! ���������������������� ����� HW Series Instructions ø22 Instructions Replacement of Lens and Marking Plate Marking • Removing For HW series illuminated pushbuttons and pilot lights, leg- ends and symbols can be engraved on the built-in marking 1. Remove the lens unit (color lens, marking plate, and lens plates, or printed film can be inserted under the lens for holder) by inserting a screwdriver into the recess of the labeling purposes. Films are not supplied with illuminated lens thorough the bezel. pushbuttons, and may be provided by the user. [Removing the Lens Unit] • Marking Plates and Marking Film Size Lens Round Lens Type Square Lens Type Style Engraving Engraving Area Area ø19.6 19.9 2. Remove the marking plate by pushing the lens from the • Engraving must be made on the engraving area within rear to disengage the latches between the lens and the 0.5mm deep. lens holder, using the screwdriver as shown below. • The marking plate is made of white acrylic resin. [Removing the Lens] 19.4 • Mylar for printing labels is not included and must be pro- vided and printed by the user. • Two 0.1mm-thick films or one 0.2mm-thick film can be installed in the lens. • Recommended marking film: Mylar Note: The translucent filter in the lens holder cannot be removed because this filter is sealed to make the unit waterproof and • Insertion Order of Marking Plate and Film oiltight. [Round Lens Type] • Installing [For Round Lens Type] Lens Marking Plate Lens Holder Lens Film Marking Lens Housing Plate Holder 1. Place the marking plate on the lens holder with the anti- Note: Films are not included. rotation projection engaged and press the lens onto the lens holder to engage the latches. [Square Lens Type] 2. Place the marking plate in the correct orientation. [For Square Lens Type] Lens Marking Plate Lens Holder Lens Film Marking Lens Housing Plate Holder 1. Place the marking plate on the lens holder and press the Note: Films are not included. lens onto the lens holder to engage the latches. Place the marking plate in the correct orientation. 2. Place the marking plate in the correct orientation. 45 Applicable Marking Film Built-in Marking Plate 1 ø21.5 22.7 1 ��������������� �����" ���������������������� ����� ø22 HW Series Instructions Instructions Replacement of Lamps Close Mounting Lamps can be replaced by using the lamp holder tool (OR- When mounting the units closely in a horizontal row on 55) from the front of the panel, or by removing the contact 30mm centers, use optional barriers to prevent interconnec- block from the operator unit. tion between adjoining terminals. The barriers can be attached simply by pressing them onto the sides of contact • Removing the Lamps from the Front of the Panel blocks. [How to Remove] 1. To remove, slip the lamp holder tool onto the lamp head lightly. Then push slightly, and turn the lamp holder tool counterclockwise. 30 30 [How to Install] 1. To install, insert the lamp head into the lamp holder tool, and hold the lamp as shown in the figure below. Lamp Lamp Holder Tool 2. Place the pins on the lamp base to the grooves in the Barrier lamp socket. Insert the lamp and turn it clockwise. When mounting transformer type illuminated units closely in Grooves in the Operator Unit a horizontal row on 30mm centers, insert solid wires or stranded wires into inside of the terminal screw on the trans- former (see figure below) to prevent short circuit between adjoining terminals. Nameplate When anti-rotation is not required, remove the projection from the nameplate using pliers. X1 X2 X1 X2 Projection Inside Inside Nameplate When using transformer type pilot lights closely mounted in horizontal and vertical rows on 30mm centers, keep the ambient temperature below 40°C. 46 ��������������� ������ ���������������������� ����� HW Series Instructions ø22 Instructions Tightening Torque for Terminal Screws Anti-rotation Ring and Panel Cut-out Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 Align the TOP marking on the operator and the ▲ mark on N·m. the anti-rotation ring with the recess in the mounting panel. Panel Thickness 1.2 to 4.5 Installation of LED Illuminated Units Projection 1. When using full voltage type LED illuminated units, pro- vide protection against electrical noise, if necessary. 2. Notes for Pure White LED Lamps • Do not use the pure white LED outdoors, otherwise it will lead to the degradation of brightness and color. Do not HW Operator Anti-rotation Locking remove or apply shock to the cap on the pure white LED Ring Ring lamp, otherwise it may break or damage the cap. Mounting Panel • Use a white lens. The illumination color will be dull if a dif- ferent color lens is used. • Panel Cut-out (Complies with IEC947-5-1) Applicable Wiring 2 +0.2 The applicable wire size is 2mm maximum. (Solid wire ø1.6 3.2 0 mm max.) One or two wires can be connected. • Applicable Crimping Terminal ø3.6 min. 4 max. 5.5 min. Unibody Pushlock Turn Reset Be sure to use an insulation tube or cover on the crimping • Removing the lens part of the crimping terminal to prevent electrical shocks. Remove the lens by inserting a screwdriver into the left or • Solid Wire right recess of the lens. Be careful that the lens does not drop off. • Removing the LED/incandescent lamp Use a lens removal tool to remove the lamp. See page 46 for more information. 8 max. • Notes for Wiring Ensure that the crimping terminal of each wiring is properly Note: Contact Block and Transformer When connecting wires in the direction shown below, keep insulated. the insulation stripping length 6.6 mm at the maximum. Key Selector Switch • Notes for using a different key When a different number key is inserted into the key hole, it will not normally operate. However, if the key is forced to X1 X2 turn or is not inserted properly, it may be turned. 47 R0.8 max. +0.4 ø22.3 0 ø1.6 max. 7.9 max. +0.4 24.1 0 ���������� ��� ������ ���������������������� �� ��! ø22 HW Series Control Boxes Control Boxes Control Box (Gray Cover) Mounted Unit Shape Contact Type No. Button Color (Operator) With Pushbutton HW1X-BM Specify a button color code in 1NO HW1X-BM110➀ place of ➀ in the Type No. HW1B-M1 B: black G: green R: red S: blue 1NO-1NC HW1X-BM111➀ W: white Y: yellow Operator Contact Block Position Mounted Unit Shape No. of Positions Contact Code Type No. Mounting (Operator) Type LC R Position With Selector Switch 1 NO — 10 HW1X-S2T10 HW1X-S (1NO) Dummy 2 90° 2-position HW1S-2T Maintained 1 NO — 11 HW1X-S2T11 (1NO-1NC) 2 NC — 1 NO 45° 3-position 20 HW1X-S3T20 HW1S-3T Maintained (2NO) 2 NO Emergency Stop Control Box (Yellow Cover) Mounted Unit Shape Contact Type No. Button Color (Operator) With Pushlock Turn Reset Switch 1NC HW1X-BV401R HW1X-BV 1NO-1NC HW1X-BV411R Red only HW1B-V4R 2NC HW1X-BV402R With Pushlock Key Reset Switch 1NC HW1X-BX401R HW1X-BX 1NO-1NC HW1X-BX411R Red only HW1B-X4R 2NC HW1X-BX402R Accessories Name Type No. Ordering Type No. Package Quantity Remarks NSA-0 1 Black surface, made of aluminum Nameplate NSA-0 0.8 mm thick NSA-0PN10 10 Cover Gasket HW9Z-W HW9Z-WPN05 5 Made of rubber HW9Z-G HW9Z-GPN05 5 Made of white plastic, G1/2 thread Connector Locking Nut HW9Z-PG HW9Z-PGPN05 5 Made of black plastic, PG16 thread Ordering Information • Unless otherwise specified, every control box is supplied with two connector locking nuts (G1/2 thread). • When using PG16 connectors, specify as described below. HW1X-BM110➀ - PG Supplied with two PG16 connector locking nuts 48 ���������� ��� ������ ���������������������� �� ��! HW Series Control Boxes ø22 Specifications Contact Ratings Operating Temperature –25 to +60°C (no freezing) Rated Insulation Voltage 600V Storage Temperature –40 to +80°C (no freezing) Rated Continuous Current 10A Contact Block Operating Humidity 45 to 80% RH (no condensation) Contact Ratings by AC-15 (A600) Utilization Category Rated Insulation DC-13 (P600) 600V IEC 60947-5-1 Voltage Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Applicable Standards and Approvals Electric Shock Safety Standards File No. or Organization Class II (IEC 61140) Protection Class UL508 UL Listing File No. E68961 Between live and dead parts: CSA C22.2 No. 14 c-UL (File No. E68961) Dielectric Strength 2,500V AC, 1 minute EN60947-5-1 TÜV PS No. B98 08 13332 398 Operating extremes: Vibration Resistance 5 to 55 Hz, amplitude 0.5 mm 2 Attachments Damage limits: 1,000 m/s Shock Resistance 2 Operating extremes: 100 m/s Name Type No. Quantity Pushbuttons, momentary: 5,000,000 Nameplate ∗1 NSA-0 1 Mechanical Life Selector switches: 500,000 Cover Gasket ∗2 HW9Z-W 1 (minimum operations) Pushlock turn reset switches: 500,000 Connector Locking Nut HW9Z-G 2 Pushbuttons, momentary: 500,000 ∗1 For details, see the instruction sheet attached to the control box. Selector switches: 500,000 ∗2 ∗1: The nameplate is supplied with the pushbutton and selector Pushlock turn reset switches: 500,000 ∗3 Electrical Life switch control boxes, not with the emergency stop control (Switching frequency) (minimum operations) box. ∗1 1,800 operations/h, duty ratio 40% ∗2: The cover gasket is supplied with the emergency stop con- ∗2 1,200 operations/h, duty ratio 40% trol box, not with the pushbutton and selector switch control ∗3 900 operations/h, duty ratio 40% boxes. Conduit Port ø23mm knockout on top and bottom Applicable Connector G1/2 or PG16 (plastic fitting) Solid wire: ø1.6mm maximum Applicable Wire 2 Stranded wire: 2.0 mm maximum Two M4 screws Mounting Screw Tightening torque 1.4 to 2.0 N·m Degree of Protection IP65 (IEC 60529) Characteristics • Contact Ratings by Utilization Category Note: Operational Voltage 24V 48V 50V 110V 220V 440V The operational current represents the AC-12 Control of resistive loads and solid 10A — 10A 10A 6A 2A classification by making and breaking state loads AC currents (IEC 60947-5-1). 50/60 Hz AC-15 Control of electromagnetic loads 10A — 7A 5A3A1A Minimum applicable load: 3V AC/DC, (> 72 VA) 5 mA (Applicable range may vary with DC-12 Control of resistive loads and solid operating conditions and load types.) 8A 4A — 2.2A 1.1A — state loads DC DC-13 Control of electromagnets 4A 2A — 1.1A 0.6A — Dimensions A 58 58 Control Unit (Operator) Dimension A (mm) Pushbutton 13.0 Selector Switch 21.0 Pushlock Turn Reset 32.0 32.0 Pushlock Key Reset (Key inserted: 49.4) HW1B-V4R Box Cover Mouting Screws Box Cover Box Base All dimensions in mm. 49 Operational Current 70 58 ���������� ��� ����"� ���������������������� �� ��! ø22 HW Series Control Boxes • Applicable Connector and Installation Mounting Hole Layout 1. To install a connector, break open the conduit port on the top and bottom of the control box. Before opening the 58 conduit port, remove the attached two connector locking nuts from the control box base. Place the tip of a screw- driver on the conduit port and strike the screwdriver end. Make sure that the conduit port is free from burs and cracks, which may hamper waterproof characteristics. Screwdriver 2-ø4.6 Applicable Terminal ø3.6 min. Tightening torque: 1.0 to 1.3 N·m A maximum of two pieces can be 2. Use G1/2 or PG16 connectors which can mount on a connected to one terminal. panel of 4.0 mm thick minimum. To install the connector to the control box, use the attached connector locking nut 4 max. 5.5 min. and tighten the locking nut sufficiently. If the locking nut is tightened insufficiently, the waterproof characteristics are not ensured. Nameplate Type No. NSA-0 Thread Size Locking Nut Color Locking Nut Type No. G1/2 White HW9Z-G 34 PG16 Black HW9Z-PG Color: Black, without legend Thickness: 1.2 mm (Remove the anti-rotation projection) Material Aluminum Locking Nut for Installing Connector The nameplate is supplied with the pushbutton and selector (supplied with control box) 4 switch control boxes. When not using the nameplate, use the cover gasket (HW9Z-W). 3. Only when using a plastic connector, Insulation Class II HW series nameplates (HWA∗) cannot be used. (IEC 61140) is satisfied. 4. Install the box cover flat on the box base. When the box Operating Instructions cover is installed diagonally, the box cover cannot be • Panel Mounting secured correctly, resulting in an operation error. To mount the control box on a panel, use two M4 screws, plane washers and spring washers to preventing loosening. • Applicable Cables Tighten the screws to a torque of 1.4 to 2.0 N·m. Applicable CVV Cable Outside Diameter Core Wires 2 1.25 mm ø14.5 mm maximum 8 maximum Determine the screw length in consideration of the panel 2 2.0 mm ø14.5 mm maximum 8 maximum thickness. 3 • Applicable Conduits Hexagonal Nut Metal Conduit Outside Diameter ø10 mm ø12 mm M4 Screw Plain Washer ø8.3 mm ø10.6 mm Conduit Inside Diameter minimum minimum 2 1.25 mm 2 to 3 4 to 6 IV Wire Quantity 2 2.0 mm 2 to 3 3 to 4 Wire containment density: 32% to 48% Spring Washer Control Box Select a cable appropriate for the connector. Panel 50 ø25.5 7.9 max. 42.4 36 30 max. ������� ����� ���������������� ������� ����� �� Specifications and other descriptions in this catalog are subject to change without notice. 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan Tel: +81-6-6398-2571, Fax: +81-6-6392-9731 www.idec.com IDEC CORPORATION (USA) IDEC IZUMI ASIA PTE. LTD. 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA No. 31, Tannery Lane #05-01, Dragon Land Building, Singapore 347788 Tel: +1-408-747-0550, Toll Free: (800) 262-IDEC, Fax: +1-408-744-9055 Tel: +65-6746-1155, Fax: +65-6844-5995 E-mail: opencontact@idec.com, www.idec.com E-mail: generalinfo@idecasia.com.sg IDEC CANADA LIMITED IDEC IZUMI (H.K.) CO., LTD. Unit 22-151, Brunel Road Mississauga, Ontario, L4Z 1X3, Canada Unit 1505-07, DCH Commercial Centre No. 25, Westlands Road,� Tel: +1-905-890-8561, Toll Free: (888) 317-4332, Fax: +1-905-890-8562 Quarry Bay, Hong Kong Tel: +852-2803-8989, Fax: +852-2565-0171 IDEC ELECTRONICS LIMITED E-mail: idec@idechk.com Unit 2, Beechwood, Chineham Business Park, Basingstoke, Hampshire RG24 8WA, UK IDEC IZUMI (Shanghai) Co., Ltd. Tel: +44-1256-321000, Fax: +44-1256-327755 Room E, 15F, Majesty Building, No. 138 Pudong Avenue, E-mail: idec@uk.idec.com Shanghai 200120, P.R.C. Tel: +86-21-5887-9181, Fax: +86-21-5887-8930 IDEC ELEKTROTECHNIK GmbH E-mail: idec@cn.idec.com Wendenstrasse 331, D-20537 Hamburg, Germany Tel: +49-40-25 30 54 10, Fax: +49-40-25 30 54 24 IDEC TAIWAN CORPORATION E-mail: service@idec.de, www.idec.de 8F, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan Tel: +886-2-2698-3929, Fax: +886-2-2698-3931 IDEC AUSTRALIA PTY. LTD. E-mail: service@idectwn.com.tw 2/3 Macro Court, Rowville, Victoria 3178, Australia Toll Free: 1-800-68-4332, Fax: +61-3-9763-3255 E-mail: sales@au.idec.com Cat. No. EP1056-0 NOVEMBER 2004 5DNP PRINTED IN JAPAN

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the HW1K-21B10?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Switch Key Lock N.C. SPST Flat Key Screw 500000Cycles Panel Mount ABN3K01-R

product

Switch Key Lock N.C. DPST Flat Key Screw 500000Cycles Panel Mount ABN3K02-R

product

Switch Key Lock N.O./N.C. DPST Flat Key 10A 440VAC 220VDC Screw 500000Cycles Panel Mount ABN3K11-R

product

Switch Key Lock ON OFF SPDT 45?? Flat Key 10A 440VAC 220VDC 745.7VA Screw 500000Cycles Panel Mount A...

product

Switch Key Lock ON OFF SPDT 45 Flat Key 10A 440VAC 220VDC 745.7VA Screw 500000Cycles Panel Mount AKW...

product

Switch Key Lock N.O./N.C. DPDT 90 Flat Key 1A 250VAC 250VDC Quick Connect/Solder 250000Cycles Panel ...