Electronics Finder chervon right Manufacturers chervon right I chervon right IDEC CORPORATION chervon right TW-T246B
About product Specifications Datasheet FAQ

IDEC CORPORATION TW-T246B

Image of IDEC CORPORATION TW-T246B

Description

Power Transformer Screw Terminal
TW-T246B

Part Number

TW-T246B

Price

Request Quote

Manufacturer

IDEC CORPORATION

Lead Time

Request Quote

Category

Magnetics »  Power Transformer

Specifications

Manufacturer

IDEC Corporation

Manufacturers Part #

TW-T246B

Sub-Category

Magnetic Power Transformers

Factory Pack Quantity

1

Datasheet

pdf file

TW_EP1070.pdf

2715 KiB

Extracted Text

ş22 TW Series Control Units General-purpose control units for various applications Low Voltage Directive Heavy-duty type for high-level protection against EMC Directive harsh environment • Highly reliable HW contact blocks are used. • Degree of protection: IP65 (IEC 60529) • UL and CSA approved, EN compliant Safety Standards File No. or Organization UL Listing UL File No. E68961 CSA File No. LR21451 EN60947-1 EN TÜV Rheinland EN60947-5-1 SpeciŢcations and Ratings Contact Ratings Rated Insulation Voltage 600V Rated Continuous Current 10A Contact Block Contact Ratings by Utilization Category AC-15 (A600) IEC 60947-5-1 DC-13 (P600) Characteristics • Contact Ratings by Utilization Category Operational Voltage 24V 48V 50V 110V 220V 440V AC-12 Control of resistive loads and solid state loads 10A — 10A 10A 6A 2A AC 50/60 Hz AC-15 Control of electromagnetic loads (> 72 VA) 10A — 7A 5A 3A 1A Operational Current DC-12 Control of resistive loads and solid state loads 8A 4A — 2.2A 1.1A — DC DC-13 Control of electromagnets 4A 2A — 1.1A 0.6A — Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types) For the control units listed below, the rated current (load switching current) is reduced to a half of the rated operational current of the contact block. The rated insulation voltage (600V) and the rated thermal current (10A) remain unchanged. • Selector switches and illuminated selector switches with contact code 2S, 3S, 4S, 2R, or 4R. HW-C (Contact Block) • M3.5 terminal screw 2-way wiring possible • Double-break rolling action silver contacts with raked surface • Snap-fit groove • Alkali-resistant • Fitting groove 66 nylon housing • Contact Block Types Contact NO NC NO (early make) NC (late break) Housing Blue Purple red Blue Purple red Push Rod Green Red Black White • Push rod Color-coded for different contacts • Snap-Ţt latch A maximum of four contact blocks in two layers can mount on the operator. Incandescent Lamp Ratings (LS Type) Type No. LS-6 LS-8 LS-2 LS-3 Lamp Base BA9S/13 Rated Voltage 6V AC/DC 12V AC/DC 18V AC/DC 24V AC/DC Wattage 1W (6.3V) 1W (18V) 1W (24V) 1W (30V) Voltage Marking Die stamped on the base Approx. 1,000 hours minimum Life (reference value) (mean value when used on the rated voltage) (06/02/17) 140 +0.4 0 ş22.3 TW Series Control Units ş22 LED Lamp Ratings (LSTD Type) Type No. LSTD-6➁ LSTD-1➁ LSTD-2➁ Lamp Base BA9S/13 Rated Voltage 6V AC/DC 12V AC/DC 24V AC/DC Voltage Range 6V AC/DC ±10% 12V AC/DC ±10% 24V AC/DC ±10% AC A, R, W, Y: 17 mA, G, PW, S: 8 mA 11 mA 11 mA Current Draw DC A, R, W, Y: 14 mA, G, PW, S: 5.5 mA 10 mA 10 mA Color Code ➁ A (amber), G (green), PW (pure white), R (red), S (blue), W (white), Y (yellow) Lamp Base Color Same as illumination color Voltage Marking Die stamped on the base Life (reference value) Approx. 50,000 hours (The luminance reduces to 50% the initial intensity when used on complete DC.) A, R, W, Y Internal Circuit G, PW, S LED Chip Protection Diode Zener Diode SpeciŢcations Operating Temperature –25 to +50°C (no freezing) Storage Temperature –40 to +80°C Operating Humidity 45 to 85% RH (no condensation) Contact Resistance 50 mΩ maximum (initial value) Insulation Resistance 100 MΩ minimum (500V DC megger) Between live and dead metal parts: 2,500V AC, 1 minute Dielectric Strength (Full voltage type illuminated units: 2,000V AC, 1 minute) Vibration Resistance Operating extremes: 5 to 55 Hz, amplitude 0.5 mm 2 Damage limits: 1,000 m/s Shock Resistance 2 Operating extremes: 100 m/s Pushbuttons, Illuminated pushbuttons Momentary: 5,000,000 Mechanical Life (minimum operations) Others: 500,000 Selector switches: 500,000 Illuminated selector switches: 500,000 Pushbuttons: 500,000 (switching frequency 1,800 operations/h, duty ratio 40%) Electrical Life (minimum operations) Illuminated pushbuttons: 500,000 (switching frequency 1,800 operations/h, duty ratio 40%) Selector switches: 500,000 (switching frequency 1,200 operations/h, duty ratio 40%) Mounting Hole Layout R0.8 max. Note 1: The 3.2 mm recess is for preventing rotation and is not necessary when the nameplate or anti-rotation +0.2 ring is not used. 3.2 (Note 1) 0 Note 2: The minimum mounting centers are applicable to switches with one layer of contact blocks (two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in consideration of convenience for wiring. • ş40mm mushroom: 40 mm minimum • 2-position, 3-position lever type selector switch: 39 mm minimum 30 (Note 2) • 4-position, 5-position lever type selector switch: 50 mm minimum Degree of Protection Type No. Unit NEMA ICS 6-110 IEC 60529 Pushbuttons, pilot lights, illuminated pushbutons, and selector switches Type 1, 2, 3, 3R, (3S), 4, 5, 12,13 IP65 A∗∗∗∗ Illuminated selector switches, key pushbuttons, key reset pushbuttons, and Type 1, 2, 3R, 5, 12, 13 IP54 key selector switches Note: (3S) of NEMA ICS 6-110 applies to the pilot lights with round lens. (06/02/17) 141 50 (45 min.) +0.4 24.1 0 ş22 TW Series Control Units (Ordering Information) Ordering Information • Specify an operator or lens color code in the Type No. • When a terminal cover is required, order an applicable terminal cover referring to page 166. • Full voltage type illuminated units are not supplied with a lamp. Order LED or incandescent lamps separately. Transformer and DC-DC converter type illuminated units contain an LED or incandescent lamp. Rated Voltage LED Lamp Incandescent 100/110V AC LSTD-6➁ LS-6 200/220V AC LSTD-6➁ LS-6 110V DC LSTD-6➁ LS-6 • All standard units are UL, CSA, EN, and TÜV approved. The Type No. development charts shown below can be used to specify control units other than those listed on the following pages. Gold-plated silver contacts are also available. Pushbuttons Illuminated Pushbuttons ABW1 11 R - MAU ALFW2 116 13 D R - MAU Optional contact Optional contact MAU: Gold-plated silver contact MAU: Gold-plated silver contact Button color code Lens color code Contact arrangement code Lamp type 10: 1NO 01: 1NC D: LED (Transformer type only) 11: 1NO-1NC 20: 2NO (blank): Incandescent 02: 2NC 21: 2NO-1NC Contact arrangement code 12: 1NO-2NC 30: 3NO 10: 1NO 01: 1NC 03: 3NC 31: 3NO-1NC 11: 1NO-1NC 20: 2NO 22: 2NO-2NC 13: 1NO-3NC 02: 2NC 21: 2NO-1NC 40: 4NO 04: 4NC 12: 1NO-2NC 30: 3NO Note: 03: 3NC 31: 3NO-1NC • Push-pull type AYW4 can have a maximum of two contact blocks. 22: 2NO-2NC 13: 1NO-3NC 40: 4NO 04: 4NC Operating voltage code Pilot Lights 99: Full voltage 16: Transformer (100/110V AC) APW2 116 D R 116: Transformer (115V AC) Lens color code 126: Transformer (120V AC) Lamp type 26: Transformer (200/220V AC) D: LED (Transformer type only) 236: Transformer (230V AC) (blank): Incandescent 246: Transformer (240V AC) Operating voltage code 386: Transformer (380V AC) 99: Full voltage 46: Transformer (400/440V AC) 16: Transformer (100/110V AC) 486: Transformer (480V AC) 116: Transformer (115V AC) 16∗D: DC-DC converter (110V DC) 126: Transformer (120V AC) Note: 26: Transformer (200/220V AC) • Push-pull type AYLW4 can have a maximum of two contact blocks. 236: Transformer (230V AC) • Transformer type and DC-DC converter type cannot have an odd 246: Transformer (240V AC) number of contact blocks, such as 1NO, 1NC, 3NO, 2NO-1NC, 386: Transformer (380V AC) 1NO-2NC, and 3NC. 46: Transformer (400/440V AC) 486: Transformer (480V AC) 16D: DC-DC converter (110V DC) Note: • Full voltage type is not supplied with a lamp. • Transformer and DC-DC converter types contain an LED lamp (LSTD-6➁) or incandescent lamp (LS-6). (06/02/17) 142 TW Series Control Units (Ordering Information) ş22 Selector Switch Illuminated Selector Switch ASLW 2 16 22 D R - MAU ASW 2 L 11 - MAU Optional contact Optional contact MAU: Gold-plated silver contact MAU: Gold-plated silver contact Contact arrangement code Lens color code Operator type Lamp type (blank): Knob D: LED (Transformer type only) L: Lever (blank): Incandescent Number of positions Contact arrangement code Note: Operating voltage code • See pages 162 to 164 for contact arrangement codes. 99: Full voltage 16: Transformer (100/110V AC) 156: Transformer (115V AC) Key Selector Switch 136: Transformer (120V AC) 26: Transformer (200/220V AC) ASW 2 K 20 B - MAU 236: Transformer (230V AC) Optional contact 256: Transformer (240V AC) MAU: Gold-plated silver contact 386: Transformer (380V AC) Key removable position code 46: Transformer (400/440V AC) 2-position 486: Transformer (480V AC) • Maintained Number of positions (blank): Removable in all positions Note: B: Removable in left only • Full voltage type is not supplied with a lamp. C: Removable in right only • Transformer type contains an LED lamp (LSTD-6➁) or incandes- • Spring return from right cent lamp (LS-6). (blank): Removable in left only • See pages 163 to 165 for contact arrangement codes. • Spring return from left (blank): Removable in right only 3-position • Maintained (blank): Removable in all positions B: Removable in left and center C: Removable in right and center D: Removable in center only E: Removable in right and left G: Removable in left only H: Removable in right only • Spring return from right (blank): Removable in left and center D: Removable in center only G: Removable in left only • Spring return from left (blank): Removable in right and center D: Removable in center only H: Removable in right only • Spring return two-way (blank): Removable in center only Contact arrangement code Number of positions Note: • See pages 163 to 165 for contact arrangement codes. • The key cannot be removed in the return position. (06/02/17) 143 ş22 TW Series Pushbuttons Flush / Extended / Extended w/Full Shroud / Mushroom Types Operation ➀ Button Color Shape Contact Type No. Dimensions (mm) Type Code Flush 1NO ABW110➀ ABW1 1NC ABW101➀ AOW1 1NO-1NC ABW111➀ M3.5 Terminal Momentary Screws 2NO ABW120➀ Panel Thickness 1 to 6 2NC ABW102➀ 2NO-2NC ABW122➀ 1NO AOW110➀ 48.5 (1-2 blocks) 1NC AOW101➀ 13 30 68.5 (3-4 blocks) 1NO-1NC AOW111➀ Maintained 2NO AOW120➀ 2NC AOW102➀ 2NO-2NC AOW122➀ Extended 1NO ABW210➀ ABW2 1NC ABW201➀ AOW2 1NO-1NC ABW211➀ M3.5 Terminal Momentary Screws Panel Thickness 1 to 6 2NO ABW220➀ 2NC ABW202➀ 2NO-2NC ABW222➀ 1NO AOW210➀ 48.5 (1-2 blocks) 13 1NC AOW201➀ Specify a button 30 68.5 (3-4 blocks) 19 1NO-1NC AOW211➀ color code in Maintained place of ➀ in the 2NO AOW220➀ Type No. 2NC AOW202➀ 2NO-2NC AOW222➀ B: black Extended with Full Shroud 1NO ABFW210➀ G: green ABFW2 1NC ABFW201➀ R: red AOFW2 1NO-1NC ABFW211➀ S: blue M3.5 Terminal Momentary Screws W: white Panel Thickness 1 to 6 2NO ABFW220➀ Y: yellow 2NC ABFW202➀ 2NO-2NC ABFW222➀ 1NO AOFW210➀ 48.5 (1-2 blocks) 19.5 1NC AOFW201➀ 30 68.5 (3-4 blocks) 1NO-1NC AOFW211➀ Maintained 2NO AOFW220➀ 2NC AOFW202➀ 2NO-2NC AOFW222➀ ş29mm Mushroom 1NO ABW310➀ ABW3 1NC ABW301➀ AOW3 1NO-1NC ABW311➀ Momentary M3.5 Terminal 2NO ABW320➀ Screws Panel Thickness 1 to 6 2NC ABW302➀ 2NO-2NC ABW322➀ 1NO AOW310➀ 1NC AOW301➀ 48.5 (1-2 block) 13 68.5 (3-4 blocks) 22.5 30 1NO-1NC AOW311➀ Maintained 2NO AOW320➀ 2NC AOW302➀ 2NO-2NC AOW322➀ • Specify a button color code in place of ➀ in the Type No. • Round bezel and shroud (metal): Mat aluminum color • Pushbuttons with one or three contact blocks contain a dummy block. • Other contact arrangements and gold-plated silver contacts are also available. See page 142. (06/02/17) 144 ş24 ş24 ş24 ş29 ş29 ş29 ş29 37 37 37 37 K C O L 45° TW Series Pushbuttons ş22 Mushroom / Pushlock Turn Reset / Push Turn Lock / Pushlock Key Reset Types Operation ➀ Button Color Shape Contact Type No. Dimensions (mm) Type Code ş40mm Mushroom 1NO ABW410➀ ABW4 1NC ABW401➀ AOW4 1NO-1NC ABW411➀ M3.5 Terminal Momentary Screws 2NO ABW420➀ Panel Thickness 1 to 6 2NC ABW402➀ 2NO-2NC ABW422➀ 1NO AOW410➀ Specify a button 48.5 (1-2 blocks) 1NC AOW401➀ 13 color code in 30 68.5 (3-4 blocks) 22.5 1NO-1NC AOW411➀ place of ➀ in the Maintained Type No. 2NO AOW420➀ 2NC AOW402➀ B: black 2NO-2NC AOW422➀ G: green ş40mm Mushroom R: red 1NO ABGW410➀ w/Full Shroud S: blue M3.5 Terminal Panel Thickness 1 to 6 ABGW4 Screw W: white 1NC ABGW401➀ Y: yellow 1NO-1NC ABGW411➀ Momentary 2NO ABGW420➀ ( ) 48.5 1-2 blocks 30 ( ) 23 68.5 3-4 blocks 2NC ABGW402➀ 2NO-2NC ABGW422➀ ş29mm Pushlock Turn Reset 1NO AVW310➀ M3.5 Terminal Panel Thickness AVW3 (Note) Screws Reset Angle 75° 1 to 6 1NC AVW301➀ 1NO-1NC AVW311➀ 2NO AVW320➀ 48.5 (1-2 blocks) 13 2NC AVW302➀ 30 68.5 (3-4 blocks) 22.5 2NO-2NC AVW322➀ R: red Y: yellow ş40mm Pushlock Turn Reset 1NO AVW410➀ M3.5 Terminal Panel Thickness AVW4 (Note) Screws Reset Angle 75° 1 to 6 1NC AVW401➀ 1NO-1NC AVW411➀ 2NO AVW420➀ 48.5 (1-2 blocks) 13 2NC AVW402➀ 30 68.5 (3-4 blocks) 22.5 2NO-2NC AVW422➀ ş40mm Push Turn Lock 1NO AJW410➀ M3.5 Terminal Panel Thickness AJW4 Screws 1 to 6 Reset Angle 75° 1NC AJW401➀ B: black 1NO-1NC AJW411➀ G: green R: red 2NO AJW420➀ Y: yellow 48.5 (1-2 blocks) 13 2NC AJW402➀ 68.5 (3-4 blocks) 22.5 30 2NO-2NC AJW422➀ ş29mm Pushlock Key Reset 1NO AXW310R M3.5 Terminal Panel Thickness AXW3 (Note) Reset Screws 1 to 6 1NC AXW301R (unlock) 1NO-1NC AXW311R Red only 2NO AXW320R 13 2NC AXW302R 48.5 (1-2 blocks) 25 68.5 (3-4 blocks) 47 30 2NO-2NC AXW322R • Specify a button color code in place of ➀ in the Type No. • Round bezel (metal): Mat aluminum color • Pushbuttons with one or three contact blocks contain a dummy block. • Other contact arrangements and gold-plated silver contacts are also available. See page 142. Note: AVW3, AVW4, and AXW3 pushbuttons cannot be used as emergency stop switches. When emergency stop switches are required, use XW or HW series pushbuttons (ISO 13850 and IEC 60947-5-5 compliant). (06/02/17) 145 H S U P ş40 ş40 ş46 ş40 ş29 ş29 37 37 37 37 37 37 45° ş22 TW Series Pushbuttons Pushlock Key Reset / Push-Pull / Square Flush / Square Extended Operation ➀ Button Color Shape Contact Type No. Dimensions (mm) Type Code ş40mm Mushroom Push Lock Key Reset 1NO AXW410R AXW4 Panel Thickness M3.5 Terminal Reset 1NC AXW401R Screws 1 to 6 (unlock) 1NO-1NC AXW411R Red only 2NO AXW420R 13 48.5 (1-2 blocks) 25 2NC AXW402R 30 68.5 (3-4 blocks) 47 2NO-2NC AXW422R ş40mm Mushroom Push-Pull 1NO AYW410➀ Panel Thickness M3.5 Terminal AYW4 1 to 6 Screws 1NC AYW401➀ 1NO-1NC AYW411➀ 13 2NO AYW420➀ 48.5 (1-2 blocks) 25 30 68.5 (3-4 blocks) 30.5 2NC AYW402➀ Square Flush 1NO ABQW110➀ ABQW1 1NC ABQW101➀ AOQW1 1NO-1NC ABQW111➀ Momentary M3.5 Terminal Panel Thickness 2NO ABQW120➀ Screws 1 to 6 2NC ABQW102➀ 2NO-2NC ABQW122➀ B: black 1NO AOQW110➀ G: green 1NC AOQW101➀ R: red 48.5 (1-2 blocks) 13 1NO-1NC AOQW111➀ S: blue 30 68.5 (3-4 blocks) Maintained W: white 2NO AOQW120➀ Y: yellow 2NC AOQW102➀ 2NO-2NC AOQW122➀ Square Extended 1NO ABQW210➀ ABQW2 1NC ABQW201➀ AOQW2 1NO-1NC ABQW211➀ Momentary M3.5 Terminal Panel Thickness 2NO ABQW220➀ Screws 1 to 6 2NC ABQW202➀ 2NO-2NC ABQW222➀ 1NO AOQW210➀ 1NC AOQW201➀ 48.5 (1-2 blocks) 13 1NO-1NC AOQW211➀ 30 68.5 (3-4 blocks) 20 Maintained 2NO AOQW220➀ 2NC AOQW202➀ 2NO-2NC AOQW222➀ • Specify a button color code in place of ➀ in the Type No. • Round bezel (metal): Mat aluminum color • Square bezel (plastic): Black • Pushbuttons with one or three contact blocks contain a dummy block. • Other contact arrangements and gold-plated silver contacts are also available. See page 142. • Contact Statuses of Push-Pull Switch ş40mm Mushroom Push-Pull Switch Contact Push Pull 1NO 1NC 1NO-1NC 2NO 2NC • Note: Push-pull switch can have a maximum of two contact blocks. (06/02/17) 146 30 25 ş40 30 25 ş40 37 37 37 37 TW Series Pilot Lights ş22 Round Flush / Dome / Square Flush Types ➁ Lens/LED Shape Lamp Input Type Type No. ➂ Operating Voltage Code Color Code Round Flush A: amber Without Lamp Full Voltage APW199➁ APW1 G: green PW: pure white Transformer APW1➂D➁ R: red S: blue LED W: white DC-DC Converter∗ APW11DD➁ Y: yellow A: amber G: green Incandescent Transformer APW1➂➁ R: red S: blue W: white Round Flush (Marking) A: amber Without Lamp Full Voltage APW1B99➁ APW1B G: green PW: pure white Transformer APW1B➂D➁ R: red S: blue LED W: white DC-DC Converter∗ APW1B16DD➁ Specify an operating Y: yellow voltage code in place of ➂ A: amber in the Type No. G: green Incandescent Transformer APW1B➂➁ R: red 16: 100/110V AC S: blue 116: 115 AC W: white 126: 120V AC Dome A: amber 26: 200/220V AC Without Lamp Full Voltage APW299➁ APW2 G: green 236: 230V AC PW: pure white 246: 240V AC Transformer APW2➂D➁ R: red 386: 380V AC S: blue LED 46: 400/440V AC W: white DC-DC Converter∗ APW216DD➁ 486: 480V AC Y: yellow A: amber G: green Incandescent Transformer APW2➂➁ R: red S: blue W: white Square Flush (Marking) A: amber Without Lamp Full Voltage APQW1B99➁ APQW1B G: green PW: pure white Transformer APQW1B➂D➁ R: red S: blue LED W: white DC-DC Converter∗ APQW1B16DD➁ Y: yellow A: amber G: green Incandescent Transformer APQW1B➂➁ R: red S: blue W: white • Specify a lens/LED color code in place of ➁ in the Type No. • The white (W) lens of APW1B and APQW1B types is a combination of clear lens and white marking plate. • Specify an operating voltage code in place of ➂ in the Type No. • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Round bezel (metal): Mat aluminum color • Square bezel (plastic): Black ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). (06/02/17) 147 ş22 TW Series Pilot Lights Dimensions • • • • • • Round Flush APW1 • • Round Flush APW1 Full Voltage Transformer, DC-DC Converter Panel Thickness Panel Thickness 1 to 6 1 to 6 M3.5 Terminal Screw 28.5 13 30 28.5 13 30 17 66.5 17 • • • • Round Flush Marking Type APW1B • • • • Round Flush Marking Type APW1B Full Voltage Transformer, DC-DC Converter Panel Thickness M3.5 Terminal Panel Thickness 1 to 6 Screw 1 to 6 28.5 13 30 28.5 13 30 17 66.5 17 Marking plate: ø15.5 mm Marking plate: ø15.5 mm • • • • Dome APW2 • • • • Dome APW2 Full Voltage Transformer, DC-DC Converter Panel Thickness M3.5 Terminal Panel Thickness 1 to 6 Screw 1 to 6 28.5 13 30 28.5 13 30 25 66.5 25 • • • • Square Flush Marking Type APQW1B • • • • Square Flush Marking Type APQW1B Full Voltage Transformer, DC-DC Converter Panel Thickness M3.5 Terminal 1 to 6 Panel Thickness 1 to 6 Screw 28.5 13 30 28.5 13 30 16 66.5 16 Marking plate: 22 mm Marking plate: 22 mm All dimensions in mm. Terminal Wiring (Bottom View) • Arrows indicate access directions for wiring. TOP TOP M3.5 M3.5 X1 X1 X2 X2 Full Voltage Type Transformer Type DC-DC Converter Type (06/02/17) 148 25 ø24 ø24 ø23.6 30 ø29 ø29 ø29 37 37 37 37 ø24 25 ø23.6 ø29 ø24 30 ø29 ø29 37 37 37 37 TW Series Illuminated Pushbuttons ş22 . Round Extended Illuminated Pushbuttons Shape Operation Type Lamp Input Type Contact Type No. Round Extended 1NO-1NC ALW29911➁ ALW2 Without Lamp Full Voltage 2NO ALW29920➁ AOLW2 2NO-2NC ALW29922➁ 1NO-1NC ALW2➂11D➁ Transformer 2NO ALW2➂20D➁ 2NO-2NC ALW2➂22D➁ Momentary LED 1NO-1NC ALW21611DD➁ DC-DC Converter∗ 2NO ALW21620DD➁ 2NO-2NC ALW21622DD➁ 1NO-1NC ALW2➂11➁ Incandescent Transformer 2NO ALW2➂20➁ 2NO-2NC ALW2➂22➁ 1NO-1NC AOLW29911➁ Without Lamp Full Voltage 2NO AOLW29920➁ 2NO-2NC AOLW29922➁ 1NO-1NC AOLW2➂11D➁ Transformer 2NO AOLW2➂20D➁ 2NO-2NC AOLW2➂22D➁ Maintained LED 1NO-1NC AOLW21611DD➁ DC-DC Converter∗ 2NO AOLW21620DD➁ 2NO-2NC AOLW21622DD➁ 1NO-1NC AOLW2➂11➁ Incandescent Transformer 2NO AOLW2➂20➁ 2NO-2NC AOLW2➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. place of ➁ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber A: amber 116: Transformer (115V AC) G: green G: green 126: Transformer (120V AC) PW: pure white R: red 26: Transformer (200/220V AC) R: red S: blue 236: Transformer (230V AC) S: blue W: white 246: Transformer (240V AC) W: white 386: Transformer (380V AC) Y: yellow 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). (06/02/17) 149 ş22 TW Series Illuminated Pushbuttons Round Extended Illuminated Pushbuttons (Marking Type) Shape Operation Type Lamp Input Type Contact Type No. Round Extended (Marking) 1NO-1NC ALW2B9911➁ ALW2B Without Lamp Full Voltage 2NO ALW2B9920➁ AOLW2B 2NO-2NC ALW2B9922➁ 1NO-1NC ALW2B➂11D➁ Transformer 2NO ALW2B➂20D➁ 2NO-2NC ALW2B➂22D➁ Momentary LED 1NO-1NC ALW2B1611DD➁ DC-DC Converter∗ 2NO ALW2B1620DD➁ 2NO-2NC ALW2B1622DD➁ 1NO-1NC ALW2B➂11➁ Incandescent Transformer 2NO ALW2B➂20➁ 2NO-2NC ALW2B➂22➁ 1NO-1NC AOLW2B9911➁ Without Lamp Full Voltage 2NO AOLW2B9920➁ 2NO-2NC AOLW2B9922➁ 1NO-1NC AOLW2B➂11D➁ Transformer 2NO AOLW2B➂20D➁ 2NO-2NC AOLW2B➂22D➁ Maintained LED 1NO-1NC AOLW2B1611DD➁ DC-DC Converter∗ 2NO AOLW2B1620DD➁ 2NO-2NC AOLW2B1622DD➁ 1NO-1NC AOLW2B➂11➁ Incandescent Transformer 2NO AOLW2B➂20➁ 2NO-2NC AOLW2B➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. place of ➁ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber A: amber 116: Transformer (115V AC) G: green G: green 126: Transformer (120V AC) PW: pure white R: red 26: Transformer (200/220V AC) R: red S: blue 236: Transformer (230V AC) S: blue W: white 246: Transformer (240V AC) W: white 386: Transformer (380V AC) Y: yellow 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). (06/02/17) 150 TW Series Illuminated Pushbuttons ş22 Round Extended with Full Shroud Illuminated Pushbuttons Shape Operation Type Lamp Input Type Contact Type No. Round Extended 1NO-1NC ALFW29911➁ With Full Shroud Without Lamp Full Voltage 2NO ALFW29920➁ ALFW2 2NO-2NC ALFW29922➁ AOLFW2 1NO-1NC ALFW2➂11D➁ Transformer 2NO ALFW2➂20D➁ 2NO-2NC ALFW2➂22D➁ Momentary LED 1NO-1NC ALFW21611DD➁ DC-DC Converter∗ 2NO ALFW21620DD➁ 2NO-2NC ALFW21622DD➁ 1NO-1NC ALFW2➂11➁ Incandescent Transformer 2NO ALFW2➂20➁ 2NO-2NC ALFW2➂22➁ 1NO-1NC AOLFW29911➁ Without Lamp Full Voltage 2NO AOLFW29920➁ 2NO-2NC AOLFW29922➁ 1NO-1NC AOLFW2➂11D➁ Transformer 2NO AOLFW2➂20D➁ 2NO-2NC AOLFW2➂22D➁ Maintained LED 1NO-1NC AOLFW21611DD➁ DC-DC Converter∗ 2NO AOLFW21620DD➁ 2NO-2NC AOLFW21622DD➁ 1NO-1NC AOLFW2➂11➁ Incandescent Transformer 2NO AOLFW2➂20➁ 2NO-2NC AOLFW2➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. place of ➁ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber A: amber 116: Transformer (115V AC) G: green G: green 126: Transformer (120V AC) PW: pure white R: red 26: Transformer (200/220V AC) R: red S: blue 236: Transformer (230V AC) S: blue W: white 246: Transformer (240V AC) W: white 386: Transformer (380V AC) Y: yellow 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). (06/02/17) 151 ş22 TW Series Illuminated Pushbuttons Round Extended with Full Shroud Illuminated Pushbuttons (Marking Type) Shape Operation Type Lamp Input Type Contact Type No. Round Extended (Marking) 1NO-1NC ALFW2B9911➁ With Full Shroud Without Lamp Full Voltage 2NO ALFW2B9920➁ ALFW2B 2NO-2NC ALFW2B9922➁ AOLFW2B 1NO-1NC ALFW2B➂11D➁ Transformer 2NO ALFW2B➂20D➁ 2NO-2NC ALFW2B➂22D➁ Momentary LED 1NO-1NC ALFW2B1611DD➁ DC-DC Converter∗ 2NO ALFW2B1620DD➁ 2NO-2NC ALFW2B1622DD➁ 1NO-1NC ALFW2B➂11➁ Incandescent Transformer 2NO ALFW2B➂20➁ 2NO-2NC ALFW2B➂22➁ 1NO-1NC AOLFW2B9911➁ Without Lamp Full Voltage 2NO AOLFW2B9920➁ 2NO-2NC AOLFW2B9922➁ 1NO-1NC AOLFW2B➂11D➁ Transformer 2NO AOLFW2B➂20D➁ 2NO-2NC AOLFW2B➂22D➁ Maintained LED 1NO-1NC AOLFW2B1611DD➁ DC-DC Converter∗ 2NO AOLFW2B1620DD➁ 2NO-2NC AOLFW2B1622DD➁ 1NO-1NC AOLFW2B➂11➁ Incandescent Transformer 2NO AOLFW2B➂20➁ 2NO-2NC AOLFW2B➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. place of ➁ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber A: amber 116: Transformer (115V AC) G: green G: green 126: Transformer (120V AC) PW: pure white R: red 26: Transformer (200/220V AC) R: red S: blue 236: Transformer (230V AC) S: blue W: white 246: Transformer (240V AC) W: white 386: Transformer (380V AC) Y: yellow 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). (06/02/17) 152 TW Series Illuminated Pushbuttons ş22 Square Extended Illuminated Pushbuttons (Marking Type) Shape Operation Type Lamp Input Type Contact Type No. Square Extended (Marking) 1NO-1NC ALQW2B9911➁ ALQW2B Without Lamp Full Voltage 2NO ALQW2B9920➁ AOLQW2B 2NO-2NC ALQW2B9922➁ 1NO-1NC ALQW2B➂11D➁ Transformer 2NO ALQW2B➂20D➁ 2NO-2NC ALQW2B➂22D➁ Momentary LED 1NO-1NC ALQW2B1611DD➁ DC-DC Converter∗ 2NO ALQW2B1620DD➁ 2NO-2NC ALQW2B1622DD➁ 1NO-1NC ALQW2B➂11➁ Incandescent Transformer 2NO ALQW2B➂20➁ 2NO-2NC ALQW2B➂22➁ 1NO-1NC AOLQW2B9911➁ Without Lamp Full Voltage 2NO AOLQW2B9920➁ 2NO-2NC AOLQW2B9922➁ 1NO-1NC AOLQW2B➂11D➁ Transformer 2NO AOLQW2B➂20D➁ 2NO-2NC AOLQW2B➂22D➁ Maintained LED 1NO-1NC AOLQW2B1611DD➁ DC-DC Converter∗ 2NO AOLQW2B1620DD➁ 2NO-2NC AOLQW2B1622DD➁ 1NO-1NC AOLQW2B➂11➁ Incandescent Transformer 2NO AOLQW2B➂20➁ 2NO-2NC AOLQW2B➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. place of ➁ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber A: amber 116: Transformer (115V AC) G: green G: green 126: Transformer (120V AC) PW: pure white R: red 26: Transformer (200/220V AC) R: red S: blue 236: Transformer (230V AC) S: blue W: white 246: Transformer (240V AC) W: white 386: Transformer (380V AC) Y: yellow 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). (06/02/17) 153 ş22 TW Series Illuminated Pushbuttons Mushroom (ş29) Illuminated Pushbuttons Shape Operation Type Lamp Input Type Contact Type No. ş29 Mushroom Without Lamp Full Voltage ALW39911➁ ALW3 Momentary AOLW3 Incandescent Transformer ALW3➂11➁ Without Lamp Full Voltage AOLW39911➁ Maintained Incandescent Transformer AOLW3➂11➁ 1NO-1NC ş29 Mushroom (Marking Type) Without Lamp Full Voltage ALW3B9911➁ ALW3B Momentary AOLW3B Incandescent Transformer ALW3B➂11➁ Without Lamp Full Voltage AOLW3B9911➁ Maintained Incandescent Transformer AOLW3B➂11➁ ş29 Mushroom Pushlock Turn Reset 1NO-1NC AVLW39911R AVLW3 Without Lamp Full Voltage 2NO AVLW39920R 2NO-2NC AVLW39922R 1NO-1NC AVLW3➂11DR LED Transformer 2NO AVLW3➂20DR 2NO-2NC AVLW3➂22DR 1NO-1NC AVLW3➂11R Incandescent Transformer 2NO AVLW3➂20R 2NO-2NC AVLW3➂22R ş29 Mushroom Pushlock Turn Reset (Marking Type) 1NO AVLW3B9911R AVLW3B Without Lamp Full Voltage 1NC AVLW3B9920R 1NO-1NC AVLW3B9922R 1NO-1NC AVLW3B➂11DR LED Transformer 2NO AVLW3B➂20DR 2NO-2NC AVLW3B➂22DR 1NO-1NC AVLW3B➂11R Incandescent Transformer 2NO AVLW3B➂20R 2NO-2NC AVLW3B➂22R • Color Code and Operating Voltage Code Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 116: Transformer (115V AC) G: green 126: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). (06/02/17) 154 TW Series Illuminated Pushbuttons ş22 Mushroom (ş40 mm) Illuminated Pushbuttons Shape Lamp Input Type Contact Type No. ş40 Mushroom Pushlock Turn Reset 1NO-1NC AVLW49911R AVLW4 Without Lamp Full Voltage 2NO AVLW49920R 2NO-2NC AVLW49922R 1NO-1NC AVLW4➂11DR LED Transformer 2NO AVLW4➂20DR 2NO-2NC AVLW4➂22DR 1NO-1NC AVLW4➂11R Incandescent Transformer 2NO AVLW4➂20R 2NO-2NC AVLW4➂22R ş40 Mushroom Pushlock Turn Reset (Marking Type) 1NO AVLW4B9911R AVLW4B Without Lamp Full Voltage 1NC AVLW4B9920R 1NO-1NC AVLW4B9922R 1NO-1NC AVLW4B➂11DR LED Transformer 2NO AVLW4B➂20DR 2NO-2NC AVLW4B➂22DR 1NO-1NC AVLW4B➂11R Incandescent Transformer 2NO AVLW4B➂20R 2NO-2NC AVLW4B➂22R ş40 Mushroom Push Pull 1NO-1NC AYLW49911➁ AYLW4 (2-position Without Lamp Full Voltage 2NO AYLW49920➁ maintained) 2NO-2NC AYLW49922➁ 1NO-1NC AYLW4➂11➁ Incandescent Transformer 2NO AYLW4➂20➁ ş40 Mushroom Push Pull (Marking Type) 1NO AYLW4B9911➁ AYLW4B Without Lamp Full Voltage 1NC AYLW4B9920➁ (2-position maintained) 1NO-1NC AYLW4B9922➁ 1NO-1NC AYLW4B➂11➁ Incandescent Transformer 2NO AYLW4B➂20➁ • Color Code and Operating Voltage Code Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 116: Transformer (115V AC) G: green 126: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white (AYLW4 only) 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer type contains an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Contact Statuses of Push-Pull Switch ş40mm Mushroom Push-Pull Switch Contact Push Pull 1NO 1NC 1NO-1NC 2NO 2NC Note: Push-pull switch can have a maximum of two contact blocks. (06/02/17) 155 ş22 TW Series Illuminated Pushbuttons Dimensions (Operator) Round Extended (non-marking/marking) Round Extended with Full Shroud Square Extended (marking) ALW2 / ALW2B / AOLW2 / AOLW2B (non-marking/marking) ALQW2B / AOLQW2B ALFW2 / ALFW2B / AOLFW2 / AOLFW2B Panel Thickness Panel Thickness 1 to 6 1 to 6 Panel Thickness 1 to 6 13 13 30 30 20 19 20 30 Marking plate: 21mm Marking plate: ø15.5mm Marking plate: ø15.5mm ş29 Mushroom (non-marking/marking) ş29 Mushroom Pushlock Turn Reset ş40 Mushroom Pushlock Turn Reset ALW3 / ALW3B / AOLW3 / AOLW3B (non-marking/marking) (non-marking/marking) AVLW3 / AVLW3B AVLW4 / AVLW4B Panel Thickness 1 to 6 Panel Thickness Panel Thickness Reset Angle: 75° Reset Angle 75° 1 to 6 1 to 6 13 30 13 13 22.5 30 22.5 Marking plate: ø13.9mm 22.5 30 Marking plate: ø13.9mm Marking plate: ø13.9mm ş40 Mushroom Push Pull (non-marking/marking) AYLW4 / AYLW4B Panel Thickness 1 to 6 13 25 30 30.5 Marking plate: ø13.9mm All dimensions in mm. Terminal Arrangement (Lamp Terminal) (Bottom View) • Arrows indicate access directions for wiring. TOP TOP TOP X1 X1 X1 X2 X2 X2 Full Voltage Type Full Voltage Type Transformer Type DC-DC Converter Type When using TW-DA1B When using HW-DA1B Full Voltage Adapter for Full Voltage Adapter for 2 or 4 contact blocks 1 or 3 contact blocks (06/02/17) 156 ø24 ø29 ø40 ø29 37 37 37 ø24 ø29 ø29 37 37 25 ø40 30 37 37 TW Series Illuminated Pushbuttons ş22 Dimensions (Behind the Panel) • Transformer Type • Full Voltage Type • DC-DC Converter Type M3.5 Panel Thickness Panel Thickness M3.5 Terminal Screws Terminal Screws 1 to 6 1 to 6 X1 X2 1 contact 2 contact 86.5 48.5 block blocks When using HW-DA1B full-voltage adapter M3.5 Panel Thickness Panel Thickness M3.5 Terminal Screws Terminal Screws 1 to 6 1 to 6 X1 X2 4 contact 106.5 63.5 2 contact blocks blocks When using TW-DA1B full-voltage adapter M3.5 Panel Thickness Terminal Screws 1 to 6 3 contact 68.5 blocks When using HW-DA1B full-voltage adapter Panel Thickness M3.5 Terminal Screws 1 to 6 83.5 4 contact blocks When using TW-DA1B full-voltage adapter Note: For the push-pull type, a maximum of two contact blocks can be used. All dimensions in mm. • Contact ConŢguration and Codes Contact ConŢguration Code 1NO 10 1 block 1NC 01 1NO-1NC 11 2 blocks 2NO 20 2NC 02 2NO-1NC 21 1NO-2NC 12 3 blocks 3NO 30 3NC 03 3NO-1NC 31 2NO-2NC 22 4 blocks 1NO-3NC 13 4NO 40 4NC 04 (06/02/17) 157 X1 X2 X1 X2 X2 X1 X2 X1 ş22 TW Series Selector Switches Selector Switches (Knob Operator Type) M3.5 Terminal Shape ASW Screws Panel Thickness 1 to 6 48.5 (2 blocks) 13 68.5 (4 blocks) 25 30 Contact Arrangement Chart Maintained Spring Return Spring Return Contact Operator Position from Right from Left Contact Block — Code L R L R L R Mounting Type LR Position 1 NO 10 ASW210 ASW2110 ASW2210 ∗ (1NO) Dummy 2 1 NO 11 ASW211 ASW2111 ASW2211 ∗ (1NO-1NC) 2 NC 1 NO 20 ASW220 ASW2120 ASW2220 ∗ — (2NO) 2 NO 1 NO 22 2 NC ASW222 ASW2122 ASW2222 ∗ (2NO-2NC) 3 NO 4 NC Maintained Spring Return Spring Return Spring Return Contact Operator Position from Right from Left Two-way Contact Block C C C C L R Code L R L R L R Mounting Type LC R Position 1 NO 20 ASW320 ASW3120 ASW3220 ASW3320 (2NO) 2 NO 1 NC 02 ASW302 ASW3102 ASW3202 ASW3302 (2NC) 2 NC 1 NO 22 2 NO ASW322 ASW3122 ASW3222 ASW3322 (2NO-2NC) 3 NC 4 NC 1 NO 40 2 NO ASW340 ASW3140 ASW3240 ASW3340 (4NO) 3 NO 4 NO 1 NC 04 2 NC ASW304 ASW3104 ASW3204 ASW3304 (4NC) 3 NC 4 NC 1 NO 2 NO 3S ★ ASW33S-243 ★ ——— 3 NC Dummy 4 Contact Maintained Maintained Operator Position • Contact Block Mounting Position Contact Block 2 3 2 4 1 3 and Contact Arrangement Chart Code 1 5 Mounting Type 12345 Position 4 Center Left Right 1 NC 2 NC 4S ★ ASW44S-407 ★ — LC R Operator 3 NC Position 4 NO 1 NO 1 NO 2 NO 2 NC 4S ★ ASW44S-411 ★ — 3 NC 3 NC 4 NC 4 NO 4 TOP 1 NO 2 2 NC • For more contact 3S ★ ASW43S-461 ★ — 3 NC arrangement chart, Dummy 4 see pages 163 to 1 NO 165. 3 2 NC 1 4S ★ — ASW54S-501 ★ 3 NC 4 NO • On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows. • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. • Selector switches with one or three contact blocks contain a dummy block. • Knob operator: White indicator on black knob (06/02/17) 158 30° 5-position / 45° 4-position 45° 3-position 90° 2-position No. of Positions ş24 ş29 37 TW Series Selector Switches ş22 Selector Switches (Lever Operator Type) Shape ASW∗L M3.5 Terminal Screws Panel Thickness 1 to 6 ( 48.5 2 blocks) 13 30 68.5 (4 blocks) 25 Contact Arrangement Chart Maintained Spring Return Spring Return Contact Operator Position from Right from Left Contact Block — L R L R L R Code Mounting Type LR Position 1 NO 10 ASW2L10 ASW21L10 ASW22L10 ∗ (1NO) Dummy 2 1 NO 11 ASW2L11 ASW21L11 ASW22L11 ∗ (1NO-1NC) NC 2 1 NO 20 ASW2L20 ASW21L20 ASW22L20 ∗ — (2NO) NO 2 1 NO 22 NC 2 ASW2L22 ASW21L22 ASW22L22 ∗ (2NO-2NC) 3 NO NC 4 Maintained Spring Return Spring Return Spring Return Contact Operator Position from Right from Left Two-way Contact Block C C C C L R Code L R L R L R Mounting Type LC R Position 1 NO 20 ASW3L20 ASW31L20 ASW32L20 ASW33L20 (2NO) 2 NO 1 NC 02 ASW3L02 ASW31L02 ASW32L02 ASW33L02 (2NC) 2 NC 1 NO 22 2 NO ASW3L22 ASW31L22 ASW32L22 ASW33L22 (2NO-2NC) 3 NC 4 NC 1 NO 40 2 NO ASW3L40 ASW31L40 ASW32L40 ASW33L40 (4NO) 3 NO 4 NO 1 NC 04 2 NC ASW3L04 ASW31L04 ASW32L04 ASW33L04 (4NC) 3 NC 4 NC 1 NO 2 NO 3S ★ ASW3L3S-243 ★ ——— 3 NC Dummy 4 Maintained Maintained Contact Operator Position • Contact Block Mounting Position Contact Block 2 3 2 4 1 3 and Contact Arrangement Chart Code 1 5 Mounting Type 12345 Position 4 Center Left Right 1 NC 2 NC 4S ★ ASW4L4S-407 ★ — LC R Operator NC 3 Position 4 NO 1 NO NO 1 2 NO 2 NC 4S ★ ASW4L4S-411 ★ — 3 NC NC 3 4 NC 4 NO 4 NO 1 TOP 2 • For more contact 2 NC 3S ★ ASW4L3S-461 ★ — arrangement chart, NC 3 see pages 163 to Dummy 4 165. NO 1 3 2 NC 1 4S ★ — ASW5L4S-501 ★ NC 3 4 NO • On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows. • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. • Selector switches with one or three contact blocks contain a dummy block. • Lever operator: White indicator on black lever (06/02/17) 159 30° 5-position / 45° 4-position 45° 3-position 90° 2-position No. of Positions ş29 ş25 37 ş22 TW Series Selector Switches Key Selector Switches M3.5 Teminal Shape ASW∗K Screws Panel Thickness 1 to 6 13 ( 48.5 2 blocks) 19 30 68.5 (4 blocks) 41 Contact Arrangement Chart Maintained Spring Return Spring Return Contact Operator Position from Right from Left Contact Block — L R L R L R Code Mounting Type LR Position 1 NO 10 ASW2K10 ASW21K10 ASW22K10 ∗ (1NO) Dummy 2 1 NO 11 ASW2K11 ASW21K11 ASW22K11 ∗ (1NO-1NC) 2 NC 1 NO 20 ASW2K20 ASW21K20 ASW22K20 ∗ — (2NO) 2 NO 1 NO 22 2 NC ASW2K22 ASW21K22 ASW22K22 ∗ (2NO-2NC) 3 NO 4 NC Maintained Spring Return Spring Return Spring Return Contact Operator Position from Right from Left Two-way Contact Block C C C C Code L R L R L R L R Mounting Type LC R Position 1 NO 20 ASW3K20 ASW31K20 ASW32K20 ASW33K20 (2NO) NO 2 1 NC 02 ASW3K02 ASW31K02 ASW32K02 ASW33K02 (2NC) NC 2 1 NO 22 NO 2 ASW3K22 ASW31K22 ASW32K22 ASW33K22 (2NO-2NC) 3 NC NC 4 1 NO 40 NO 2 ASW3K40 ASW31K40 ASW32K40 ASW33K40 (4NO) 3 NO NO 4 1 NC 04 NC 2 ASW3K04 ASW31K04 ASW32K04 ASW33K04 (4NC) 3 NC NC 4 1 NO NO 2 3S ★ ASW3K3S-243 ★ ——— 3 NC Dummy 4 • On the spring-returned types, the key can be released only from the maintained position. On the maintained types, the key can be released from every position. Key retained positions are also available. See page 143. • On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows. • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. • Key selector switches with one or three contact blocks contain a dummy block. • Cylinder cover: Black, Cylinder: Metal • Contact Block Mounting Position and Contact Arrangement Chart Center Left Right 4 2 TOP Operator LC R Position 1 NO 2 NO 3 1 3 NC 4 NC • For more contact arrangement chart, see pages 163 to 165. (06/02/17) 160 45° 3-position 90° 2-position No. of Positions ş24 ş29 37 TW Series Selector Switches ş22 Illuminated Selector Switches 90° 2-position Shape ASLW M3.5 Terminal Screws Panel Thickness 1 to 6 13 A: 63.5 (2 blocks) 30 ( 25 83.5 4 blocks) A: Rated voltage 24V AC/DC B: 86.5 (2 blocks), 106.5 (4 blocks) B: Rated voltage 100/110V AC, 200/220V AC Contact Arrangement Chart Maintained Spring Return Spring Return Contact Operator from Right from Left Contact Block Position Lamp Input Type L R L R L R Code Mounting Type LR Position 1 NO Without Lamp Full Voltage ASLW29911➁ ASLW219911➁ ASLW229911➁ 11 2 NC LED Transformer ASLW2➂11D➁ ASLW21➂11D➁ ASLW22➂11D➁ (1NO-1NC) Incandescent Transformer ASLW2➂11➁ ASLW21➂11➁ ASLW22➂11➁ 1 NO Without Lamp Full Voltage ASLW29920➁ ASLW219920➁ ASLW229920➁ 20 2 NO LED Transformer ASLW2➂20D➁ ASLW21➂20D➁ ASLW22➂20D➁ (2NO) Incandescent Transformer ASLW2➂20➁ ASLW21➂20➁ ASLW22➂20➁ 1 NO Without Lamp Full Voltage ASLW29922➁ ASLW219922➁ ASLW229922➁ 2 NC 3 NO 22 LED Transformer ASLW2➂22D➁ ASLW21➂22D➁ ASLW22➂22D➁ (2NO-2NC) 4 NC Incandescent Transformer ASLW2➂22➁ ASLW21➂22➁ ASLW22➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. place of ➁ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber A: amber 156: Transformer (115V AC) G: green G: green 136: Transformer (120V AC) PW: pure white R: red 26: Transformer (200/220V AC) R: red S: blue 236: Transformer (230V AC) S: blue W: white 256: Transformer (240V AC) W: white 386: Transformer (380V AC) Y: yellow 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer type contains an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Contact Block Mounting Position and Contact Arrangement Chart 4 Left Right TOP 2 LR Operator Position 1 NO 3 2 NC 1 3 NO 4 NC • For more contact arrangement chart, see pages 163 to 165. (06/02/17) 161 ş24 ş29 37 ş22 TW Series Selector Switches Illuminated Selector Switches 45° 3-position Maintained Spring Return Spring Return Spring Return Contact Operator from Right from left Two-way Contact Lamp Block Position C C C C L R L R L R L R Code Input Type Mounting Type LC R Position Without Lamp 1 NO ASLW39920 ASLW319920 ASLW329920 ASLW339920 Full Voltage LED 20 2 NO ASLW3➂20D➁ ASLW31➂20D➁ ASLW32➂20D➁ ASLW33➂20D➁ (2NO) Transformer Incandescent ASLW3➂20➁ ASLW31➂20➁ ASLW32➂20➁ ASLW33➂20➁ Transformer Without Lamp 1 NC ASLW39902 ASLW319902 ASLW329902 ASLW339902 Full Voltage LED 02 2 NC ASLW3➂02D➁ ASLW31➂02D➁ ASLW32➂02D➁ ASLW33➂02D➁ (2NC) Transformer Incandescent ASLW3➂02➁ ASLW31➂02➁ ASLW32➂02➁ ASLW33➂02➁ Transformer 1 NO Without Lamp ASLW39922 ASLW319922 ASLW329922 ASLW339922 2 NO Full Voltage 22 3 NC LED ASLW3➂22D➁ ASLW31➂22D➁ ASLW32➂22D➁ ASLW33➂22D➁ (2NO-2NC) Transformer 4 NC Incandescent ASLW3➂22➁ ASLW31➂22➁ ASLW32➂22➁ ASLW33➂22➁ Transformer 1 NO Without Lamp ASLW39940 ASLW319940 ASLW329940 ASLW339940 2 NO Full Voltage 40 3 NO LED ASLW3➂40D➁ ASLW31➂40D➁ ASLW32➂40D➁ ASLW33➂40D➁ (4NO) Transformer 4 NO Incandescent ASLW3➂40➁ ASLW31➂40➁ ASLW32➂40➁ ASLW33➂40➁ Transformer 1 NC Without Lamp ASLW39904 ASLW319904 ASLW329904 ASLW339904 2 NC Full Voltage 04 3 NC LED ASLW3➂04D➁ ASLW31➂04D➁ ASLW32➂04D➁ ASLW33➂04D➁ (4NC) Transformer 4 NC Incandescent ASLW3➂04➁ ASLW31➂04➁ ASLW32➂04➁ ASLW33➂04➁ Transformer • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens/LED Color Code ➁ Lens Color Code Specify a lens/LED color code in Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. place of ➁ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber A: amber 156: Transformer (115V AC) G: green G: green 136: Transformer (120V AC) PW: pure white R: red 26: Transformer (200/220V AC) R: red S: blue 236: Transformer (230V AC) S: blue W: white 256: Transformer (240V AC) W: white 386: Transformer (380V AC) Y: yellow 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 172. • LED illuminated transformer type contains an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Contact Block Mounting Position and Contact Arrangement Chart Center Left Right 4 TOP 2 LC R Operator 1 NO Position 2 NO 3 3 NC 1 • For more contact arrangement chart, see pages 163 to 165. 4 NC (06/02/17) 162 TW Series Selector Switch Contact Arrangement Charts ş22 90° 2-position (Maintained / Spring Return) Spring Maintained Return Spring Return from Left from Right Positions L R L R L R Operator Types Knob, Lever, Key, Illuminated Operator Positions Contact Circuit Mounting Type Code No. Position LRLR 1 NO 10 — (1NO) 2 Dummy 1 NC 01 — (1NC) 2 Dummy 1 NO — 2 NC 11 (1NO-1NC) 1 NC 103 2 NO 1 NO 20 — (2NO) 2 NO 1 NC 02 — (2NC) 2 NC 1 NO 2 NC — 3 NO 4 NC 1 NO • • • • Contact Block Mounting Position and 2 NC 109 3 NC Contact Arrangement Chart 4 NO 4 TOP 1 NC 2 2 NO 22 110 (2NO-2NC) 3 NC 4 NO 3 1 NO 1 2 NO 111 3 NC 4 NC Left Right 1 NC 2 NO 117 3 NO LR Operator 4 NC Position 1 NO 1 NC 2 NC 2 NO 31 107 3 NO (3NO-1NC) 3 NO 4 NC 4 NO 1 NO 2 NO 40 — (4NO) • On the contact arrangement marked with 3 NO ★ in the table, the rated current (load 4 NO 1 NO switching current) is reduced to a half of 118 ★ 2 NC the rated current of the contact block. 1 NO The rated insulation voltage and the rated 168 ★ 2 NC thermal current remain unchanged. 2R ★ 1 NC 119 ★ 2 NO 1 NC 169 ★ 2 NO Type No. Development 1 NO 2 NC • When circuit number is not required: 120 ★ 3 NO 4 NC ASW 2 11 1 NO Contact Code (1NO-1NC) 2 NC 2-position 170 ★ 3 NO 4 NC • When circuit number is required: 4R ★ 1 NC ASW 2 11 - 103 2 NO 121 ★ 3 NC Circuit No. 4 NO Contact Code (1NO-1NC) 1 NC 2-position 2 NO 171 ★ 3 NC 4 NO (06/02/17) 163 ş22 TW Series Selector Switch Contact Arrangement Charts 45° 3-position (Maintained / Spring Return) Spring Return Spring Return Spring Return Maintained from Right from Left Two-way C C C C Positions L R L R L R L R Operator Types Knob, Lever, Key, Illuminated Operator Positions Contact Circuit Mounting Type Code No. Position LC R 1 NO 202 2 NC 1 NC 203 2 NO 11 1 NO 302 2 NC 1 NC 303 2 NO 1 NO — 2 NO 20 1 NO 301 2 NO 1 NC — 2 NC 02 1 NC 304 2 NC 1 NO 2 NO — 3 NC 4 NC 1 NC 2 NO 210 3 NC 4 NO 1 NO 2 NC 22 308 (2NO-2NC) 3 NO 4 NC • • • • Contact Block Mounting Position and 1 NO Contact Arrangement Chart 2 NC 309 3 NC 4 TOP 4 NO 2 1 NC 2 NO 310 3 NC 4 NO 3 1 NO 1 2 NC 206 3 NO 4 NO 31 Center Left Right (3NO-1NC) 1 NC 2 NO 207 3 NO Operator LC R Position 4 NO 1 NO 1 NO 2 NO 2 NC 212 3 NC 3 NC 4 NC 4 NC 13 1 NC 2 NO 313 3 NC 4 NC Type No. Development 1 NO 2 NO — • When circuit number is not required: 3 NO 4 NO ASW 3 22 40 1 NO Contact Code (2NO-2NC) 2 NO 3-position 305 3 NO 4 NO • When circuit number is required: 1 NC 2 NC ASW 3 22 - 210 — 3 NC Circuit No. 4 NC 04 Contact Code (2NO-2NC) 1 NC 2 NC 3-position 314 3 NC 4 NC (06/02/17) 164 TW Series Selector Switch Contact Arrangement Charts ş22 45° 3-position (Maintained) 45° 4-position (Maintained) Maintained Maintained 2 C Positions Positions L R 1 3 4 Knob, Lever, Key, Operator Types Knob, Lever Operator Types Illuminated Operator Positions Operator Positions Contact Circuit Mounting Type Code No. Position Contact Circuit Mounting Type Code No. Position 1234 LC R 1 NO 1 NO 2 NC 2S ★ 1361 ★ 3S ★ 461 ★ 2 NC 3 NC 1 NO 4 Dummy 2 NO 1 NC 3S ★ 243 ★ 3 NC 2 NC 405 ★ 4 Dummy 3 NC 1 NO 4 NC 2 NC 1 NC 233 ★ 3 NO 2 NC 407 ★ 4 NO 3 NC 1 NO 4 NO 4S ★ 2 NC 1 NO 234 ★ 3 NC 2 NC 409 ★ 4 NC 3 NC 1 NC 4 NC 2 NO 1 NO 4S ★ 235 ★ 3 NC 2 NC 411 ★ 4 NO 3 NC 1 NO 4 NO 2 NO 237 ★ 3 NC 4 NO 30° 5-position (Maintained) 1 NC Maintained 2 NC 240 ★ 3 2 4 3 NC Positions 1 5 4 NO Operator Types Knob, Lever Operator Positions Contact Circuit Mounting 45° 3-position (Maintained) Type Code No. Position Maintained 12345 C 1 NO Positions L R 2 NC 4S ★ 501 ★ 3 NC Knob, Lever, Operator Types 4 NO Illuminated Operator Positions Contact Circuit Mounting Type Code No. Position 4 LC R Center TOP Left Right 2 1 NO 2 NO 1336 ★ Operator LC R 3 NC Position 1 NO 4 NC 3 1 NC 2 NC 1 2 NO 3 NO 1337 ★ 3 NC 4 NO 4 NC 1 NO 2 NC • On the contact arrangement marked with ★ in the 4S★ 1352 ★ 3 NC table, the rated current (load switching current) is 4 NO reduced to a half of the rated current of the contact 1 NO block. The rated insulation voltage and the rated 2 NC thermal current remain unchanged. 1355 ★ 3 NO 4 NC 1 NC 2 NC 1359 ★ 3 NC 4 NC (06/02/17) 165 ş22 TW Series Accessories and Replacement Parts Terminal Covers HW-VL2 HW-VL3 HW-VL4 HW-VL5 HW-VL6 APS-PVL Terminal Cover Use of termi- nal covers increases the depth by the dimen- sions below. Terminal Cover Control Unit 39.8H × 14.1W 37.8H × 26W 39.8H × 8.7W 39.1H × 15.5W 40H × 14.8W 36H × 29.4W • Pilot light APW Full Voltage X +6mm APQW X +3mm Transformer DC-DC Converter X +3mm • Pushbutton 1 contact block ABW AOW X CB Terminal Cover AVW ABQW ABFW AJW 2 contact blocks AOQW X AOFW CB 2 pieces AXW CB ABGW AYW +3.5mm 3 contact blocks • Selector X switch CB CB 2 pieces ASW CB 4 contact blocks X CB CB 2 pieces CB CB • Illuminated Full Voltage, 1 or 3 contact blocks pushbutton X ALW +3.5mm CB 2 pieces AOLW FA ALFW AOLFW ALQW Full Voltage, 2 or 4 contact blocks X X AOLQW For con- For full AVLW +3mm CB tact blocks voltage AYLW CB 2 pieces adapter • Illuminated selector Transformer switch DC-DC Converter ASLW X +3mm CB Tr CB • Ordering Terminal Covers Terminal covers are ordered separately. When ordering terminal covers, specify the Type No. and required quantity. (06/02/17) 166 Y C N S E T G TW Series Accessories and Replacement Parts ş22 Nameplates NWA, NWAQ, NWAS, NWAR, NWAL, NWAQL, and NWAV Dimensions Ordering Type Package Legend Material Type No. Description (mm) No. Quantity NWA NWA-0 1 Blank NWA-0 Black 29 NWA-0PN10 10 Aluminium OFF 0.8 mm thick NWA-∗ 1 White letters on With Legend NWA-∗ black background NWA-∗PN10 10 NWAQ NWAQ-0 1 Blank NWAQ-0 Black 29 NWAQ-0PN10 10 Aluminium OFF 0.8 mm thick NWAQ-∗ 1 White letters on With Legend NWAQ-∗ black background NWAQ-∗PN10 10 NWAS 45 NWAS-0 1 Aluminium Blank NWAS-0 Black 0.8 mm thick NWAS-0PN10 10 NWAR NWAR-0 1 Blank NWAR-0 Yellow NWAR-0PN10 10 Aluminium 0.8 mm thick NWAR-27 1 Black letters on EMERGENCY NWAR-27 yellow back- STOP NWAR-27PN10 10 ground NWAL NWAL-0 1 29 Aluminium Blank NWAL-0 Black 0.8 mm thick NWAL-0PN10 10 NWAQL NWAQL-0 1 29 Aluminium Blank NWAQL-0 Black 0.8 mm thick NWAQL-0PN10 10 HWAV Blank HWAV-0 HWAV-0 1 Yellow Plastic Black letters on EMERGENCY HWAV-27 HWAV-27 1 yellow back- STOP ground • Specify a legend code in place of ∗ in the Ordering Type No. Legends Code Legend 0 (blank) 1ON 2 OFF 3START 4STOP 31 OFF-ON 35 HAND-AUTO 53 HAND-OFF-AUTO (06/02/17) 167 O R P E M E ş60 ş70 45 14.5 25 25 14.5 21 20 ş22 TW Series Accessories and Replacement Parts Accessories Ordering Package Shape Material Type No. Dimensions Type No. Quantity • Used to tighten the round bezel when installing Locking Ring Wrench the TW control unit onto a panel. Rubber OR-14 OR-14 1 90 16 For ş22mm units For ş22/ş25mm units (close mounting) • Used to install and remove LED/incandescent Lamp Holder Tool lamps. Rubber OR-55 OR-55 1 59 • Used to remove contact blocks, transformers, Contact Block Removal Tool lenses and adapters. Can also be used to determine panel thickness adjustment. Metal/Rubber TW-KC1 TW-KC1 1 130 • Used to tighten the locking nuts inside of the Nut Locking Wrench square bezel.This tool can be inserted into the OR-14 locking ring wrench. 20 Metal TW-KQ2 TW-KQ2 1 80 • Used to prevent the operator from rotating. Anti-rotation Ring Generally used when using no nameplates on selector switches. Metal OGL-31 OGL-31PN10 10 ş22 ş27.4 0.8 • Used to plug unused ş22.2mm mounting holes. Rubber Mounting Hole Plug Rubber (black) OB-31 OB-31PN05 5 Metallic Mounting Hole Plug • Used to plug unused ş22.2mm mounting holes. • Tightening torque: 1.2 N·m • Degree of protection: IP66 (without the 3.2mm Diecast Metal recess in the mounting hole) LW9Z-BM LW9Z-BM 1 (locking ring: ş25.8 plastic) Gasket Locking Ring Barrier • Used to prevent contact between adjacent lead wires when units are mounted closely. Barriers should be Plastic HW-VL1 HW-VL1PN10 10 always used in close mounting. 20 1.5 (06/02/17) 168 ş29 ş25 ş19 12 ş11.6 23 10.2 ş46 22.5 39 45 ş31 ş34 ş14 25.7 3.5 3.5 3 R66.5 ş22.2 TW Series Accessories and Replacement Parts ş22 Accessories Ordering Package Shape Material Type No. Description Type No. Quantity • Oiltight rubber boot used for pushbuttons and Contact Rubber selector switches. Boot For 1 layer of • Temperature range: –5 to +60°C contact blocks • Black OCW-99 OCW-99 1 (2 contact blocks) OCW-99 Rubber (nitryl) 45.5 38 14 For 2 layers of contact blocks OCW-299 OCW-299 1 (4 contact OCW-299 blocks) 14 65.5 38 Pushbutton • Used to cover and pro- For ţush tect pushbuttons Clear Boot where units are sub- pushbuttons OC-31 OC-31 1 ject to water splash. (ABW1/AOW1) Not suitable for out- Rubber door use or where the (EPDM) units are subject to oil For extended splash. pushbuttons OC-32 OC-32 1 ( ) 18 OC-31 22 (OC-32) (ABW2/AOW2) • Metallic bezels covered with rubber boot to Button Cover enhance waterproof and oiltight characteristics. • Button is installed in the cover. Remove the but- For ţush ton from the pushbutton before using the button pushbuttons OCW-10➀ OCW-10➀ 1 cover. (ABW1/AOW1) • ➀: B (black), G (green), R (red), Y (yellow) 9 9 P1.0 P1.0 Rubber M22 M22 (nitryl) For extended pushbuttons OCW-11➀ OCW-11➀ 1 Button Button 18.5 21 installed installed (ABW2/AOW2) Flush Extended • Used to protect momentary and maintained Padlock Cover pushbuttons, illuminated pushbuttons, knobs selector switches, and key selector switches. 82.5 Panel Thickness 0.8 to 3.2 Polyarylate (gasket: nitryl HW9Z-KL1 HW9Z-KL1 1 rubber) 24 (inside) Waterproof Rubber 29.5 Gasket 0.5t Key hole ş8 30 ş40mm Lens ➁: G (green), R (red) ALW4L-➁ ALW4L-➁ 1 S (blue) Non-marking • Applicable unit: ALW3, AOLW3 Type ➁: A (amber), ALW4LD-➁ ALW4LD-➁ 1 W (white) Plastic ➁: G (green), R (red), ALW4BL-➁ ALW4BL-➁ 1 • Applicable unit: S (blue), W (white) ALW3B, AOLW3B Marking Type • Marking plate is included ALW4BLD-➁ ALW4BLD-➁ 1 ➁: A (amber) Note: Specify a button color code or lens color code in place of ➀ or ➁ in the Ordering Type No. (06/02/17) 169 ş50 (ID: ş44.4) 70 30 ş32 48 50 ş31 ş32 2.2 ş32.6 93 ş26 ş31 R42.5 ş22 TW Series Accessories and Replacement Parts Accessories Ordering Package Shape Material Type No. Dimensions Type No. Quantity Plastic Bezel ➀Flush AW-RP1B AW-RP1BPN05 5 ➀ ➁ ➀ ➁ ➁Extended AW-FP1B AW-FP1B 1 ➂Extended ş29 ş29 (for illuminated AW-FP2B AW-FP2B 1 ➂ Plastic Black pushbuttons) ➂ ➃ ➃Square round (for round AW-H1B AW-H1B 1 ➃ ➄ pushbuttons) ş29 30 ➄Square AW-Q1B AW-Q1B 1 Aluminium color Aluminium Bezel AW-R1 AW-R1PN05 5 (standard) ➄ ➀Flush ➀➁ AW-R1B AW-R1B 1 Black 30 ➁Extended AW-F1 AW-F1 1 Aluminium ➂ ➅ ➂Extended (for ➅ Aluminium color illuminated AW-F2 AW-F2 1 (standard) ş46 pushbuttons) ş46 ➃Mushroom AW-G4 AW-G4 1 Selector Operator ➀Knob ASWHHY-➁ ASWHHY-➁PN02 2 Specify a color code in place of ➁. ➀ ➁ B (black), G (green), R (red) ➁Lever ASWHHL-➁ ASWHHL-➁PN02 2 ➂Round ASWHHM-B ASWHHM-BPN02 2 Black only Specify a color code in place of ➁. ➂ ➃Color Insert TW-HC1➁ TW-HC1➁PN05 5 B (black), G (green), R (red), S (blue), Plastic W (white), Y (yellow) Specify a color code in place of ➁. ASLWDDY-➁ ASLWDDY-➁ 1 ➄ A (amber), W (white), Y (yellow) ➃ ➄Illuminated selector Specify a color code in place of ➁. ASLWLDY-➁ ASLWLDY-➁ 1 G (green), R (red), S (blue) • Used to protect ţush pushbuttons from Metal Protector inadvertent operation. 18.6 Metal OLW-C OLW-C 1 ş22.5 15 1.6t Maintenance Parts Color Ordering Package Shape SpeciŢcation Type No. Type No. Quantity Housing Push Rod Contact Block 1NO contact HW-C10 HW-C10 1 Blue Green 1NC contact HW-C01 HW-C01 1 Purple red Red EM contact HW-C10R HW-C10R 1 Blue Black (early make) LB contact Purple red White HW-C01R HW-C01R 1 (late break) • Used for non-illuminated units with Dummy Block 1NO or 1NC contact blocks. • Black TW-DB TW-DBPN10 10 • Adapter with M3.5 screws used for Full Voltage Adapter illuminated pushbutton or illuminated (for 2 or 4 contact blocks) selector switch. Snaps on to the back TW-DA1B TW-DA1BPN02 2 of the contact block. • Used with 2 or 4 contact blocks. • Black • Adapter with M3.5 screws used for Full Voltage Adapter illuminated pushbuttons or illumi- (for 1 or 3 contact blocks) nated selector switch. HW-DA1B HW-DA1BPN02 2 • Used with 1 or 3 contact blocks. • Black (06/02/17) 170 Mounting Centers 50 min. 19.8 13 13 23 23 19.8 13 TW Series Accessories and Replacement Parts ş22 Maintenance Parts Package Shape Material Type No. Ordering Type No. Color Code Quantity G (green), R (red), S (blue) Lens (for pilot lights) APW1L-➁ APW1L-➁PN05 5 AS APW1LD-➁ APW1LD-➁PN05 5 A (amber), W (white), Y (yellow) Round ţush C (clear), G (green), R (red), APW11L-➁ APW11L-➁PN05 5 AS, S (blue) Marking type APW11LD-➁ APW11LD-➁PN05 5 A (amber), Y (yellow) APW2L-➁ APW2L-➁PN05 5 G (green), R (red), S (blue) Round extended AS APW2LD-➁ APW2LD-➁PN05 5 A (amber), W (white), Y (yellow) C (clear), G (green), R (red), APQW11L-➁ APQW11L-➁PN05 5 AS, S (blue) Square ţush Marking type APQW11LD-➁ APQW11LD-➁PN05 5 A (amber), Y (yellow) Lens (for illuminated ALW2L-➁ ALW2L-➁PN05 5 G (green), R (red), S (blue) AS pushbuttons) ALW2LD-➁ ALW2LD-➁PN05 5 A (amber), W (white), Y (yellow) Round extended C (clear), G (green), R (red), ALW21L-➁ ALW21L-➁PN05 5 AS, S (blue) Marking type ALW21LD-➁ ALW21LD-➁PN05 5 A (amber), Y (yellow) C (clear), G (green), R (red), ALQW21L-➁ ALQW21L-➁PN05 5 S (blue) Square extended AS ALQW21LD-➁ ALQW21LD-➁PN05 5 A (amber), Y (yellow) ALW3L-➁ ALW3L-➁PN02 2 G (green), R (red), S (blue) AS ALW3LD-➁ ALW3LD-➁PN02 2 A (amber), W (white), Y (yellow) Lens (for pushlock ş29mm mushroom C (clear), G (green), R (red), ALW31L-➁ ALW31L-➁PN02 2 turn reset) AS, S (blue) Marking type ALW31LD-➁ ALW31LD-➁PN02 2 A (amber), Y (yellow) AS AVLW3L-R AVLW3L-RPN02 2 ş29mm mushroom AS, AVLW31L-R AVLW31L-RPN02 2 Marking type ş40mm mushroom AS AVLW4L-R AVLW4L-RPN02 2 Round ţush ABW1B-➀ ABW1B-➀PN05 5 Button Round extended ABW2B-➀ ABW2B-➀PN05 5 B (black) G (green) Square ţush ABQW1B-➀ ABQW1B-➀PN05 5 R (red) S (blue) Square extended ABQW2B-➀ ABQW2B-➀PN05 5 W (white) Y (yellow) ş29mm mushroom ABW3B-➀ ABW3B-➀PN02 2 Polyacetal ş40mm mushroom ABW4B-➀ ABW4B-➀PN02 2 ş29mm pushlock turn AVW3B-➀ AVW3B-➀PN02 2 R (red), Y (yellow) reset ş40mm pushlock turn AVW4B-➀ AVW4B-➀PN02 2 R (red), Y (yellow) reset B (black), G (green), R (red), ş40mm push pull AYW4B-➀ AYW4B-➀PN02 2 S (blue), W (white), Y (yellow) Marking Plate (for pilot lights) Round ţush APW2B APW2BPN05 5 Square ţush APQW1B APQW1BPN05 5 Marking Plate Round extended ALW2B ALW2BPN05 5 (for illuminated Acrylic • White pushbuttons) Square extended ALQW2B ALQW2BPN05 5 ş29/40mm mushroom ALW3B ALW3BPN05 5 Waterproof Lens For APQW APW00LN APW00LNPN05 5 Acrylic For ALQW APW00L APW00LPN05 5 Note: Specify a button color code or lens color code in place of ➀ or ➁ in the Ordering Type No. Use a clear lens for white or pure white illumination. (06/02/17) 171 ş22 TW Series Accessories and Replacement Parts Maintenance Parts Shape Material Type No. Ordering Type No. Package Quantity Spare Key For Key Selector Switch Metal TW-SK-0 TW-SK-0PN02 2 For Pushlock Key Reset LED Lamps (LSTD Type) Current Draw Ordering Illumination Package Operating Voltage Type No. Base Type No. Color Code Quantity AC DC 6V AC/DC ±5% Specify a color code LSTD-6➁ 1 in place of ➁ in the 17 mA (A, R, W, Y) 14 mA (A, R, W, Y) LSTD-6➁ Ordering Type No. 8 mA (G, PW, S) 5.5 mA (G, PW, S) LSTD-6➁PN10 10 A: amber 12V AC/DC ±10% G: green LSTD-1➁ 1 PW: pure white 11 mA 10 mA LSTD-1➁ BA9S/13 R: red LSTD-1➁PN10 10 S: blue W: white 24V AC/DC ±10% Y: yellow LSTD-2➁ 1 11 mA 10 mA LSTD-2➁ LSTD-2➁PN10 10 Incandescent Lamps (LS Type) Rated Operating Voltage Lamp Ratings Type No. Package Quantity 6V AC/DC 1W (6.3V) LS-6 12V AC/DC 1W (18V) LS-8 1 18V AC/DC 1W (24V) LS-2 24V AC/DC 1W (30V) LS-3 Transformer Shape Primary Voltage Secondary Voltage Type No. Transformer Unit 100/110V AC TW-T16B 120V AC TW-T126B 5.5V 200/220V AC TW-T26B 240V AC TW-T246B (06/02/17) 172 TW Series Instructions ş22 Safety Precautions • Turn off the power to the TW series control units before • Use HW-C type contact blocks for the TW series. Do not starting installation, removal, wiring, maintenance, and replace with or add conventional TW series contact blocks. inspection of the products. Failure to turn power off may Using a different type of contact block may lead to malfunc- cause electrical shocks or Ţre hazard. tion. • To avoid a burn on your hand, use the lamp holder tool HW-C Type TW Type when replacing lamps. Contact Block Contact Block • For wiring, use wires of a proper size to meet the voltage and current requirements. Tighten the M3.5 terminal Rectangular screws to a tightening torque of 1.0 to 1.3 N·m. Failure to Holes tighten terminal screws may cause overheat and Ţre. Instructions Panel Mounting Panel thickness adjustment ring is used for the TW series. To attach the TW series to the panel, follow the procedures below. ➁Attaching the Unit to the Panel ➂Attaching the Button, Lens, and ➀Panel Thickness Adjustment with the Bezel Knob Bezel Mounting order Panel Lens Panel thickness adjustment ring Panel Installation method Type Method Flush/Extended pushbuttons, Attach the unit with the panel Press in Square lens, Selector operator Remarks thickness scale facing up. 29mm/40mm mushroom Screw in button/lens, Dome lens For tightening or removing round Locking ring wrench bezels. For tightening or removing square Tools Nut locking wrench bezels. For installing or removing water- Contact block removal For installing or removing round Panel thickness adjustment proof lenses after the bezel is tool lenses. attached. • Using the Contact Block Removal Tool to Adjust Panel Adjusting Panel Thickness Thickness The panel thickness ring provides adjustment from 1 to 6 Panel thickness can easily be adjusted to the values shown mm in 1-mm increments. Set the panel thickness to line A. below by inserting the contact block removal tool between Rotate the ring until the desired thickness indication around the adjustment ring and base. the periphery is aligned with line A, as shown below. Panel Thickness Scale on Adjustment (in 0.1 mm) 1.6 mm Contact Block Adjustment Ring 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0 Removal Tool 2.3 mm 0.1 mm 3.5 mm 1 1 mm Panel Thickness Scale 2 3 (in 1 mm on the operator) 4 5 6 1 mm 2 mm A 2 3 3 3.2 mm 4 4 5 5 66 Ex. Panel thickness 2 mm Ex. Panel thickness 2.6 mm Note: When a nameplate or an anti-rotation ring is used, add 0.8mm to the panel thickness. Total thickness = Panel thickness + 0.8mm (nameplate or anti-rotation ring thickness) (06/02/17) 173 ş22 TW Series Instructions Instructions • Square Bezel Mounting into Panel Cut-out with Bezel 1. Insert the base plate from • Insertion into Panel Cut-out Base Plate the front. Insert the base into the panel cut-out making sure that the panel thickness scale is facing up. Panel thickness adjustment ring 2. Insert the lock nut. For easy installation, use the Lock Nut nut locking wrench. • Round Bezel All round bezels are screw-in Remove type. Be sure to use the locking ring wrench to tighten the bezel. Nut Locking Wrench Tighten TW-KQ2 (optional) Locking Ring Wrench OR-14 (optional) 3. Mount the square bezel. Square Bezel Side A The bezel will snap onto the base plate. Use side B when Side B mounting the units closely. • Recommended tightening torque is 2.0 N·m. • Marking Plate Engraving Area Installing Buttons, Lenses, and Operators • Lens Structure and Marking Plate Square (Illuminated Round Mushroom Square (Pilot Light) Pushbutton) All square lens units are marking types. To engrave on the marking plate, remove the marking plate from the lens. [Square Pilot Lens] 1. Removing the Square Lens Insert the screwdriver into the recess of the lens and lightly push out the lens. Marking Plate Flat screwdriver (5mm wide at maximum) Note: The depth of the engraving must be within 0.5 mm. • Installing Round Lens and Waterproof Lens When installing or removing round lens of pilot lights and illu- 2. Removing the Marking minated pushbuttons and waterproof lens of square pilot [Square Illuminated Pushbutton] Plate lights and illuminated pushbuttons, press the rubber part of • Pilot Light the contact block removal tool onto the lens or waterproof Insert the screwdriver into the lens for secure tightening and easy removal. recess of the lens. Marking Plate Small ţat screwdriver Lens Retainer Waterproof Lens • Illuminated Pushbuttons Insert the screwdriver into the hook and lightly push out the lens. Flat screwdriver [Round Marking Type] (5mm wide at maximum) Lens 3. Other Notes Marking Plate The square lens of the illumi- nated pushbutton cannot be Press in used without waterproof lens. Always use the waterproof lens. Be sure to use the marking plate even when it is not engraved. (06/02/17) 174 ş14 1.5 0.9 ş13 Square Lens Square Lens Press in Insert 2.6 22 1.2 21 4.4 21 1.0 19 TW Series Instructions ş22 Instructions • Installation of Selector Operators • Removing the Operator 1. The shaft of each selector or illuminated selector switch 1.Removing the Color has a recess to identify in which direction to install the Insert Recess operator. Align the operator with the recess and press in Insert a ţat screwdriver into the operator. the recess of the color 2. Press color insert (non-illuminated type) into the opera- insert. Turn the screwdriver tor. The color insert retains the operator. to push out the insert from Flat Color insert screwdriver the operator Recess Press in 2.Removing the Operator (Non-illuminated) Press in Push the operator sideways as shown in the left photo to remove the operator. Illuminated Selector Switch Selector Switch (non-illuminated) 2-Position, 90° 3-Position, 45° 4-Position, 45° 5-Position, 30° 2 3 L R C 4 1 3 2 L R 1 5 4 3.Removing the Operator (Illuminated) Recess Insert a ţat screwdriver into the recess of the operator and turn the screwdriver to remove the operator. Flat screwdriver [Example] L C L C R L C R R Standard Position The non-illuminated operators can be installed in positions other than the standard position as shown above. Removing Contact Blocks, Transformers Collective Mounting and Full Voltage Adapters When mounting the units closely in a horizontal row on 30- mm centers, use optional barriers to prevent interconnection Insert the end of the contact block removal tool into the between adjoining terminals. The barriers can be attached snap-Ţt latch of the contact block (or transformer, full-volt- simply by pressing them onto the sides of contact blocks. age adapter) and pull the tool as shown below. 30 30 Pull Barrier (HW-VL1) Tightening Torque for Terminal Screws Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m. (06/02/17) 175 ş22 TW Series Instructions Installation of LED Illuminated Units 1. Note the polarity for wiring when connecting to DC-DC 3. Notes for Pure White LED Lamps converter unit. • Do not use the pure white LED outdoors, otherwise it will lead to the degradation of brightness and color. Do not Terminal No. Polarity remove or apply shock to the cap on the pure white LED X1 Positive lamp, otherwise it may break or damage the cap. X2 Negative • For the pure white LED, use a white lens. The illumination 2. Transformer type units are recommended for use in color will be dull if a different color is used. areas subjected to noise. Notes on LED Illuminated Units LED lamps consist of semiconductors. If the applied voltage [Protection Example 1] For AC circuit exceeds the rated voltage, LED elements may deteriorate due to overheat, resulting in signiŢcant decrease in lumi- LED with transformer nance, hue change, or failure of lighting. Also, if an extrane- ous noise, transient voltage, or transient current is applied to C C the circuit, similar effects may occur. When using LED LED with Relay LED Ry LED transformer R coil or R lamps, observe the following instructions. solenoid • Rated Voltage (Reference values) R: 120Ω The LED lamps are rated at 6V, 12V, or 24V AC/DC, and C: 0.1 μF can be used within ±10% the rated voltage of either AC or [Protection Example 2] For DC circuit DC. + • DC Power 1. Switching power supply (Reference values of the diode) Regulated voltage from switching power supply is best Forward current: More than the Ry coil current Reverse withstand voltage: Ry coil current × 10 suited. Make sure to use within the rated voltage of the Relay Diode Ry LED LED lamp. coil or solenoid 2. Rechargeable battery – Note that the battery voltage may exceed the rated volt- • Countermeasures against Dim Lighting age of the LED lamp while the battery is being charged 1. Leakage currents through the transistors or a contact and immediately after the charging is complete. Be sure protection circuit may cause the LED lamp to illuminate to use the LED lamp on a voltage of ±10% the rated volt- dimly even when the output is off. age. 2. When the LED lamp is illuminated by a transistor output, 3. Full-wave rectiŢcation take the following measure. Since the LED lamp is AC/DC compatible, a diode bridge for rectiŢcation is not necessary. If the LED lamp is used [Circuit Example] on a full-wave rectiŢcation current through a diode bridge, Connect shunt resistor R in parallel with the LED lamp. the rectiŢer diodes will reduce the voltage, resulting in lower luminance. 4. Single-phase half-wave rectiŢcation R LED This is not suitable for the power source of LED lamps. Use constant-voltage DC power. Io • Noise Io: Leakage current when the output is off LED elements deteriorate due to extraneous noise, resulting R: Shunt resistor in signiŢcant decrease in luminance, hue change, or failure of lighting. When such effects are anticipated, take a protec- tion measure shown below, such as RC elements or a surge absorber. (06/02/17) 176

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the TW-T246B?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Power Transformer 110V/120V Prim AP2-0126D

product

Power Transformer 220V/240V Prim AP2-0246D

product

Power Transformer 110V/120V Prim AP6-0126D

product

Power Transformer 220V/240V Prim AP6-0246D

product

Power Transformer Screw Terminal Flange Mount TWD-0126

product

Power Transformer Screw Terminal Flange Mount TWD-0246