Electronics Finder chervon right Manufacturers chervon right I chervon right IDEC CORPORATION chervon right XA1E-LV302Q4-R
About product Specifications Datasheet FAQ

IDEC CORPORATION XA1E-LV302Q4-R

Image of IDEC CORPORATION XA1E-LV302Q4-R

Description

Switch Emergency Stop N.C. DPST Mushroom Button 3A 250VAC 250VDC 10.5N Solder Panel Mount
XA1E-LV302Q4-R

Part Number

XA1E-LV302Q4-R

Price

Request Quote

Manufacturer

IDEC CORPORATION

Lead Time

Request Quote

Category

Switches »  Switch Emergency Stop

Specifications

Manufacturer

IDEC Corporation

Manufacturers Part #

XA1E-LV302Q4-R

Lead Time

9 Week Lead Time

Industry Aliases

XA1E-LV302Q4R

Sub-Category

Emergency Stop Switches

Factory Pack Quantity

1

Datasheet

pdf file

EP1093-0_XA.pdf

302 KiB

Extracted Text

Think Automation and beyond... ş16mm XA Series Emergency Stop Switches (Illuminated Type) ş16mm XA Series Illuminated Emergency Stop Switches The World’s First ş16 mm, 4-contact Emergency Stop Switch. Compact size - only 27.9 mm deep behind the panel. • 1 to 4NC main contacts and 1NO monitor contact • The depth behind the panel is only 27.9 mm for 1 to 4 contacts. • IDEC’s original “Safe break action” ensures that the con- tacts open when the contact block is detached from the operator. • Push-to-lock, Pull or Turn-to-reset operator • Two operator sizes: ş29 and ş40 mm • Safety lock mechanism (IEC60947-5-5, 6.2) • Degree of protection IP65 (IEC60529) • Direct opening action mechanism (IEC60947-5-5, 5.2, IEC60947-5-1, Annex K) • UL, c-UL recognized. EN compliant • RoHS compliant (EU directive 2002/95/EC). Contains no lead, cadmium, mercury, hexavalent chromium, PBB, or Direct Opening Action PBDE. Specifications Illumination Ratings IEC60947-5-1, EN60947-5-1 Applicable Standards IEC60947-5-5 (Note), EN60947-5-5 (Note) Rated Voltage Operating Voltage Rated Current JIS C8201-5-1, UL508, CSA C22.2 No. 14 24V AC/DC 24V AC/DC ±10% 11 mA Operating Temperature –25 to +55°C (no freezing) Note: Except for stop switches (operator color: gray). Operating Humidity 45 to 85% RH (no condensation) Storage Temperature –45 to +80°C Contact Ratings Push to lock: 10.5N Operating Force Pull to reset: 10N (NC main contacts/NO monitor contact) Turn to reset: 0.16 N·m Rated Insulation Voltage (Ui) 300V (illuminated part: 60V) Minimum Force Rated Current (Ith) 5A Required for Direct 60N Opening Action Rated Operating Voltage (Ue) 30V 125V 250V Minimum Operator Resistive Load –3A 3A Stroke Required for 4.0 mm (AC-12) AC Direct Opening Action 50/60 Hz Inductive Load – 1.5A 1.5A Maximum Operator (AC-15) Main 4.5 mm Stroke Contacts Resistive Load 2A 0.4A 0.2A Contact Resistance 50 mΩ maximum (initial value) (DC-12) DC Insulation Resistance 100 MΩ minimum (500V DC megger) Inductive Load 1A 0.22A 0.1A (DC-13) Overvoltage Category II Resistive Load Impulse Withstand – 1.2A 0.6A 2.5 kV (AC-12) Voltage AC 50/60 Hz Inductive Load Pollution Degree 3 (inside LED unit: 2) – 0.6A 0.3A (AC-14) Monitor Operation Frequency 900 operations/hour Contacts Resistive Load 2 Operating extremes: 150 m/s 2A 0.4A 0.2A Shock Resistance (DC-12) 2 Damage limits: 1000 m/s DC Inductive Load Operating extremes: 10 to 500 Hz, amplitude 0.35 1A 0.22A 0.1A (DC-13) 2 mm acceleration 50 m/s Vibration Resistance Damage limits: 10 to 500 Hz, amplitude 0.35 • Minimum applicable load: 5V AC/DC, 1 mA (reference value) 2 mm acceleration 50 m/s (Operating area may vary according to the operating conditions and load types.) Mechanical Life 250,000 operations minimum • The rated operating currents are measured at resistive/inductive load types 100,000 operations minimum Electrical Life specified in IEC 60947-5-1. 250,000 operations minimum (24V AC/DC, 100 mA) Degree of Protection IP65 (IEC60529) Approval Organization/ Standard Mark 250V/10A fuse File No. Short-circuit Protection (Type aM, IEC60269-1/IEC60269-2) Conditional UL508 1000A UL/c-UL File No. E68961 Short-circuit Current CSA C22.2 No. 14 Terminal Style Solder terminal, PC Board terminal Recommended TÜV Product Service Tightening Torque 0.88 N·m for Locking Ring EN60947-5-1 2 EN60947-5-5 (Note) Connectable Wire 1.25 mm maximum (AWG16 maximum) European Commission’s Low Soldering Conditions 310 to 350°C, 3 seconds maximum Voltage Directive Weight ş29 mm type: 23g, ş40 mm type: 28g CCC Note: Except for stop switches (operator color: gray). GB14048.5 No. 2005010305150899 2 Rated Operating Current 3-ş1.7 holes +0.2 ş16.2 0 ş16mm XA Series Illuminated Emergency Stop Switches Types Illuminated Solder Terminal / PC Board Terminal Types Type No. NC Main NO Monitor Operator Appearance Terminal Style Contact Contact Color Solder Terminal PC Board Terminal ş29mm Operator 1NC — XA1E-LV301Q4R XA1E-LV301Q4VR 2NC — XA1E-LV302Q4R XA1E-LV302Q4VR 3NC — XA1E-LV303Q4R XA1E-LV303Q4VR 4NC — XA1E-LV304Q4R XA1E-LV304Q4VR 1NC 1NO XA1E-LV311Q4R XA1E-LV311Q4VR 2NC 1NO XA1E-LV312Q4R XA1E-LV312Q4VR 3NC 1NO XA1E-LV313Q4R XA1E-LV313Q4VR Dark red only ş40mm Operator 1NC — XA1E-LV401Q4R XA1E-LV401Q4VR 2NC — XA1E-LV402Q4R XA1E-LV402Q4VR 3NC — XA1E-LV403Q4R XA1E-LV403Q4VR 4NC — XA1E-LV404Q4R XA1E-LV404Q4VR 1NC 1NO XA1E-LV411Q4R XA1E-LV411Q4VR 2NC 1NO XA1E-LV412Q4R XA1E-LV412Q4VR 3NC 1NO XA1E-LV413Q4R XA1E-LV413Q4VR • Terminal cover (XA9Z-VL2) is ordered separately. Dimensions Panel Cut-out Mounting Panel Thickness: 0.5 to 3.7 • • +0.2 • • Illuminated Type 1.7 0 All dimensions in mm. Rubber Gasket Locking Ring Terminal Cover XA9Z-VL2 25.8 2.1 25.8 20.6 29.4 3.1 ş29mm Operator 30.4 30.4 20.6 ş40mm Operator PC Board Terminal Type Solder Terminal Type PC Board Layout (Bottom View) LED Unit Internal Circuit 19.8 8.7 X1 R1 R2 X2 4.5 LED LED chip R3 Protection diode Terminal Arrangement (Bottom View) Illuminated Type 6.5 • • • • With NO monitor contacts • • • • NC main contacts only NC main contacts: Terminals 1-2 NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 Mounting Hole Layout +0.2 TOP TOP ş16.2 0 1 2 1 2 XY LED LED ş29mm Operator 40 mm minimum Left Right Left Right X1 X2 X1 X2 ş40mm Operator 50 mm minimum Y • The values shown above are the minimum 2 1 4 3 dimensions for mounting with other ş16 mm pushbuttons. For other control units of different sizes and styles, determine the 1NC: Terminals on right 1NC: Terminals on top values according to the dimensions, opera- 2NC: Terminals on right and left 2NC: Terminals on right and left X tion, and wiring convenience. 3NC: Terminals on right, left, and top 3 10-ş1.2 holes ş29 ş40 ş29.8 30.4 19.8 8.7 11.2 27.2 19.8 8.7 4.5 1 2 2 1 1 2 +0.2 2 1 17.9 0 ş16mm XA Series Illuminated Emergency Stop Switches Nameplates Description Legend Type No. Material Plate Color Legend Color (blank) HAAV-0 For ş29mm Operator EMERGENCY STOP HAAV-27 Polyamide Yellow Black (blank) HAAV4-0 For ş40mm Operator EMERGENCY STOP HAAV4-27 Accessories and Replacement Parts Ordering Package Description & Appearance Material Type No. Remarks Type No. Quantity Terminal Cover •White PBT XA9Z-VL2 XA9Z-VL2PN02 2 •Used for solder terminals. LED Unit For Solder Terminal XA9Z-LED2R XA9Z-LED2R •Replacement LED unit/ For PC Board Terminal XA9Z-LED2VR XA9Z-LED2VR 1 LED Unit Removal Tool Stainless Steel MT-101 MT-101 •Used for removing the LED unit. Removing the LED Unit Installing the LED Unit Pull out the LED unit while squeezing the latches on the LED unit using Align the to of the LED unit with the TOP marking on the contact block. Push the LED unit into the contact block. the LED unit removal tool (MT-101). Squeeze the LED unit on the latches and pull out. TOP side Latches TOP side Safety Precautions • Turn off power to the XA series emergency stop switch before • Use wires of the proper size to meet the voltage and current starting installation, removal, wiring, maintenance, and inspec- requirements, and solder the wires correctly. If soldering is tion of the relays. Failure to turn power off may cause electrical incomplete, the wire may heat during operation, causing Ţre shock or Ţre hazard. hazard. • Use the LED unit removal tool when replacing the LED unit to • Read the user’s manual to ensure correct operation before start- avoid burn on your hands. ing installation, wiring, operation, maintenance, and inspection of the XA emergency stop switches. Specifications and other descriptions in this catalog are subject to change without notice. 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan Tel: +81-6-6398-2571, Fax: +81-6-6392-9731 E-mail: products@idec.co.jp IDEC CORPORATION (USA) IDEC IZUMI (H.K.) CO., LTD. IDEC ELEKTROTECHNIK GmbH 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Unit 1505-07, DCH Commercial Centre No. 25, Wendenstrasse 331, D-20537 Hamburg, Germany Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Westlands Road, Tel: +49-40-25 30 54 10, Fax: +49-40-25 30 54 24 Fax: +1-408-744-9055 / (800) 635-6246 Quarry Bay, Hong Kong E-mail: service@idec.de E-mail: opencontact@idec.com Tel: +852-2803-8989, Fax: +852-2565-0171 IDEC AUSTRALIA PTY. LTD. E-mail: info@hk.idec.com IDEC CANADA LIMITED 2/3 Macro Court, Rowville, Victoria 3178, Australia Unit 22-151, Brunel Road Mississauga, Ontario, Tel: +61-3-9763-3244, Toll Free: 1800-68-4332, IDEC (SHANGHAI) CORPORATION L4Z 1X3, Canada Fax: +61-3-9763-3255, E-mail: sales@au.idec.com Room 608-609, 6F, Gangtai Plaza, No. 700, Tel: +1-905-890-8561, Toll Free: (888) 317-4332, Yan'an East Road, Shanghai 200030, China IDEC IZUMI ASIA PTE. LTD. Fax: +1-905-890-8562 Tel: +86-21-5353-1000, Fax: +86-21-5353-1263 No. 31, Tannery Lane #05-01, Dragon Land Building, E-mail: sales@ca.idec.com E-mail: idec@cn.idec.com Singapore 347788 IDEC ELECTRONICS LIMITED IDEC TAIWAN CORPORATION Tel: +65-6746-1155, Fax: +65-6844-5995 Unit 2, Beechwood, Chineham Business Park, 8F, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, E-mail: info@sg.idec.com Basingstoke, Hampshire, RG24 8WA, UK Taipei County, Taiwan Tel: +44-1256-321000, Fax: +44-1256-327755 Tel: +886-2-2698-3929, Fax: +886-2-2698-3931 www.idec.com E-mail: sales@uk.idec.com E-mail: service@idectwn.com.tw Cat. No. EP1093-0 FEBRUARY 2006 14DNP PRINTED IN JAPAN

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the XA1E-LV302Q4-R?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Switch Emergency Stop N.C. SPST Mushroom Button 10A 440VAC 220VDC Screw Panel Mount AVD301N-R

product

Switch Emergency Stop N.C. DPST Mushroom Button 10A 440VAC 220VDC Screw Panel Mount AVD302N-R

product

Switch Emergency Stop N.O. SPST Mushroom Button 10A 440VAC 220VDC Screw Panel Mount AVD310N-R

product

Switch Emergency Stop N.O./N.C. SPST/SPST Mushroom Button 10A 440VAC 220VDC Screw Panel Mount AVD311...

product

Switch Emergency Stop N.C. DPST Mushroom Button 10A 440VAC 220VDC Screw Panel Mount AVLD312602DN-R

product

Switch Emergency Stop N.C. DPST Mushroom Button 10A 440VAC 220VDC Screw Panel Mount AVLD39902DN-R-12...