Electronics Finder chervon right Manufacturers chervon right L chervon right LITTELFUSE, INC. chervon right DECASMDC050F/60-2
About product Specifications Datasheet FAQ

LITTELFUSE, INC. DECASMDC050F/60-2

Image of LITTELFUSE, INC. DECASMDC050F/60-2

Description

PTC Resettable Fuse 0.55A(hold) 1.1A(trip) 60VDC 10A 1W 0.1s 0.4Ohm SMD Solder Pad 2018 T/R Automotive
DECASMDC050F/60-2

Part Number

DECASMDC050F/60-2

Price

Request Quote

Manufacturer

LITTELFUSE, INC.

Lead Time

Request Quote

Category

Circuit Protection »  PTC Resettable Fuse

Specifications

Manufacturer

Littelfuse, Inc.

Manufacturers Part #

DECASMDC050F/60-2

Industry Aliases

DECASMDC050F/60-2

Sub-Category

PTC Resettable Fuses

Packaging

Tape and Reel

Factory Pack Quantity

1000

Datasheet

pdf file

littelfuse_ptc_telenetwork_catalog_datasheet.pdf.pdf

555 KiB

Extracted Text

POLYSWITCH RESETTABLE DEVICES Telecommunications and Networking Devices The PolySwitch families of telecommunications and networking devices help meet the growing demand for resettable overcurrent protection. These product families help pr ovide protection against damage caused by power cross and power induction surges as defined in ITU, Telcordia GR1089 and UL60950. Available in chip, surface-mount and radial-leaded configurations, Littelfuse’s PolySwitch devices help improve the reliability of customer premise and network equipment worldwide. BENEFITS APPLICATIONS • Choice of many product options helps engineers by • Modems improving design flexibility • Phone sets • Compatible with high-volume electronics assembly • Fax machines • Assist in meeting regulatory equipment requirements • Phone wall outlets • Help improve line balance • Alarm systems • Applicable for legacy POTS and modern digital • PBX systems communications equipment • MDF modules • Analog and digital line cards FEATURES • T1/E1 equipment • RoHS compliant • xDSL modems and splitters • Resettable overcurrent protection • Powered ethernet systems • Surface-mount, radial-leaded and chip form factors • VoIP (Voice over Internet Protocol) equipment • Fast time-to-trip • LAN, WAN equipment • Agency recognition: UL, CSA, TÜV • Customer premise equipment • Resistance-sorted and matched devices available • Access network hardware • Low parasitic capacitance/flat impedance with frequency RoHS 232 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Application Guide for Telecommunications and Networking Devices* To use this guide, follow the steps below: 1. Select your equipment type from the guide below. 2. Select the type of protection depending on the agency and regional specifications in the second column. 3. Select the form factor for your application. 4. Use the Agency Specification/ PolySwitch Device Selection Guide on the next page to select a specific part number for each application based on the agency requirements. 5. Parts with fast time-to-trip or low resistance are available. Please consult a Littelfuse PolySwitch representative. Overcurrent Protection Region/ Form Factor Application Specification Radial-leaded Surface-mount Chip Customer Premise equipment North America TRF600-150 TS600-170F TIA-968-A, TR600-150F-EX TS600-200F IT equipment UL 60950, TRF600-160 TSM600-250F Analog Modems, V.90 Modems, ‡ GR1089 Port Type 3 TRF600-250 TSM600-400F ISDN Modems, xDSL Modems, TRF-600-400 Europe/Asia/ TRF250-120 TS250-130F TCF250-120 ADSL Splitters, Phone Sets, Fax Machines, South America TRF250-120T TSV250-130F TCF250-145 Answering Machines, Caller ID, Internet ITU K.21 TRF250-120U TSV250-184F TCF250-180T Appliances, PBX Systems, POS Terminals, TRF250-120UT TSL250-130F TRF250-145 Wall Plugs TRF250-145T TRF250-145U TRF250-180 TRF250-183 TRF250-183U TRF250-184 Access network equipment (†) North America TRF600-160 TS600-170F ‡ GR1089 Port Type 5 TRF600-250 TS600-200F Remote Terminals, Line Repeaters, TRF600-400 TS600-400F Multiplexers, Cross-Connects, TSM600-250F WAN Equipment TSM600-400F Europe/Asia/ TRF250-120 TS250-130F TCF250-120 South America TRF250-120T TSV250-130F TCF250-145 ITU K.45 TRF250-120U TSV250-184F TCF250-180T TRF250-120UT TSL250-130F TRF250-145 TRF250-145T TRF250-145U TRF250-180 TRF250-183 TRF250-183U TRF250-184 RoHS 233 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Application Guide for Telecommunications and Networking Devices* (Cont’d) Overcurrent Protection Region/ Form Factor Application Specification Radial-leaded Surface-mount Chip Central office switching equipment (†) North America TRF600-160 TS600-170F ‡ GR1089 Port Type 1 TRF600-250 TS600-200F Analog/POTS Linecards, ISDN Linecards, TRF600-400 TS600-400F xDSL Modems, ADSL/VDSL Splitters, TSM600-250F T1/E1 Linecards, Multiplexers, TSM600-400F Europe/Asia/ TRF250-120 TS250-130F TCF250-120 CSU/DSU, Servers South America TRF250-120T TSV250-130F TCF250-145 ITU K.20 TRF250-120U TSV250-184F TCF250-180T TRF250-120UT TSL250-130F TRF250-145 TRF250-145T TRF250-145U TRF250-180 TRF250-183 TRF250-183U TRF250-184 Primary protection modules (†) North America TRF250-180 TSV250-184F Telcordia GR-974 TRF250-183 MDF modules, Network Interface TRF250-184 Devices (NID) Europe/Asia/ TRF250-055T TSL250-080F TCF250-100T South America TRF250-055UT TS250-130F TCF250-120 ITU K.20 TRF250-080T TSV250-130F TCF250-120T TRF250-080U TSV250-184F TCF250-145 TRF250-110U TSL250-130F TCF250-145T TRF250-120 TCF250-180T TRF250-120T TRF250-120U TRF250-120UT TRF250-145 TRF250-145T TRF250-145U TRF250-180 TRF250-183 TRF250-183U TRF250-184 RoHS 234 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Application Guide for Telecommunications and Networking Devices* (Cont’d) Overcurrent Protection Region/ Form Factor Application Specification Radial-leaded Surface-mount Chip Short-haul/intrabuilding communications North America TRF250-080T TSL250-080F TCF250-120 ‡ GR1089 Port Type 2 TRF250-080U TS250-130F TCF250-145 equipment (†) ‡ GR1089 Port Type 4 TRF250-120 TSV250-130F TCF250-180T LAN Equipment, VoIP Cards, Cable TRF250-120T TSV250-184F TRF250-120U TSL250-130F Telephony NIUs, Wireless Local Loop TRF250-120UT Handsets TRF250-145 TRF250-145T TRF250-145U TRF250-180 TRF250-183 TRF250-183U TRF250-184 Europe/Asia/ TRF250-120 TS250-130F TCF250-120 South America TRF250-120T TSV250-130F TCF250-145 ITU K.21 TRF250-120U TSV250-184F TCF250-180T TRF250-120UT TSL250-130F TRF250-145 TRF250-145T TRF250-145U TRF250-180 TRF250-183 TRF250-183U TSV250-184 LAN Intrabuilding Power Cross Protection North America TRF250-080T TSL250-080F TCF250-120 ‡ GR1089 Port Type 4 TRF250-080U TS250-130F TCF250-145 LAN Equipment, VoIP Cards, IP Phones TRF250-120 TSV250-130F TCF250-180T TRF250-120T TSV250-184F TRF250-120U TSL250-130F TRF250-120UT TRF250-145 TRF250-145T TRF250-145U TRF250-180 TRF250-183 TRF250-183U TRF250-184 IEEE 802.3AF/AT Power over Ethernet protection decaSMDC050F/60-2** Powered Ethernet Switches and Terminals, IP phones, Wireless LAN Base Stations, Microcellular Base Stations, VoIP Cards * This list is not exhaustive. Littelfuse welcomes our customers’ input for additional application ideas for PolySwitch resettable devices. † For improved line balance in these applications, resistance-matched parts are recommended. ‡ May require additional impedance or coordination with primary protector. ** For details on decaSMDC050F/60-2, please refer to surface-mount devices product brochure. RoHS 235 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Use the guide below to select the PolySwitch devices which are typically used in your application. The following pages contain the specifications for the part numbers recommended below. PolySwitch devices assist telecommunication equipment in meeting the applicable protection requirements of these industry specifications. Refer to individual agency specifications for test procedures and circuit schematics. Users should independently evaluate the suitability of and test each product for their application. Family Product* Lightning Power Cross/Contact/Induction TCF250 TCF250-100T ITU K.20 – 1.0kV 10/700µs PRC YD/T694 2 GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 0.2A s 2 † ITU K.20/21/45 – 1A s GR-1089 Port Type 4 – 120V , 25Asc AC TCF250-120 ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230V , 10Ω AC † 2 TCF250-120T ITU K.20/21/45 – 4.0kV 10/700µs ITU K.20/21/45 – 0.2A s 2 † TCF250-145 GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A s 2 † TCF250-145T ITU K.20/21/45 – 10A s TCF250-180T GR-1089 Port Type 4 – 120V , 25Asc AC TRF250 TRF250-055T ITU K.20 – 1.0kV 10/700µs ITU K.20 – 230V , 10Ω AC 2 TRF250-055UT GR-1089 Port Types 2 and 4 – 1st Level ITU K.20 – 0.2A s 2 † TRF250-080T ITU K.20 – 1A s TRF250-080U GR-1089 Port Type 4 – 120V , 25Asc AC TRF250-110U ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230V , 10Ω AC † 2 TRF250-120 ITU K.20/21/45 – 4.0kV 10/700µs ITU K.20/21/45 – 0.2A s 2 † TRF250-120T GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A s 2 † TRF250-120U ITU K.20/21/45 – 10A s TRF250-120UT GR-1089 Port Type 4 – 120V , 25Asc AC TRF250-145 TRF250-145T TRF250-145U TRF250-180 TRF250-183 TRF250-183U TRF250-184 ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230V , 10Ω** AC ‡ 2 ITU K.20/21/45 – 4.0kV 10/700µs ITU K.20/21/45 – 0.2A s 2 ‡ GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A s 2 ‡ ITU K.20/21/45 – 10A s GR-1089 Port Type 4 – 120V , 25Asc AC TS250/TSV250 TSV250-130F ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230V , 10Ω AC † 2 TS250-130F ITU K.20/21/45 – 4.0kV 10/700µs ITU K.20/21/45 – 0.2A s 2 † GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A s 2 † ITU K.20/21/45 – 10A s GR-1089 Port Type 4 – 120V , 25Asc AC TS250-130F-RB ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230V , 10Ω AC ‡ 2 ITU K.20/21/45 – 4.0kV 10/700µs ITU K.20/21/45 – 0.2A s 2 ‡ GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A s 2 ‡ ITU K.20/21/45 – 10A s GR-1089 Port Type 4 – 120V , 25Asc AC TSV250-184F ITU K.20/21/45 – 1.5kV 10/700µs ITU K.20/21/45 – 230V , 10Ω** AC ‡ 2 ITU K.20/21/45 – 4.0kV 10/700µs ITU K.20/21/45 – 0.2A s 2 ‡ GR-1089 Port Types 2 and 4 – 1st Level ITU K.20/21/45 – 1A s 2 ‡ ITU K.20/21/45 – 10A s GR-1089 Port Type 4 – 120V , 25Asc AC TSL250 TSL250-080F GR-1089 Port Types 2 and 4 – 1st Level GR-1089 Port Type 4 – 120V , 25Asc AC TSL250-130F ITU K.20 – 1.0kV 10/700µs ITU K.20/21/45 – 230V , 10Ω AC 2 ITU K.20/21/45 – 0.2A s 2 † ITU K.20/21/45 – 1A s RoHS 236 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Agency Specification/Selection Guide (Cont’d) Family Product* Lightning Power Cross/Contact/Induction TRF600 TRF600-150 TIA-968-A Types A & B UL60950 – 600V , 40Asc AC †† TR600-150F-EX GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level UL60950 – 600V , 40Asc AC †† TRF600-160 GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level Telcordia GR-1089 – 600V , 60Asc AC †† TRF600-250 GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level Telcordia GR-1089 – 600V , 60Asc AC TRF600-400 GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level Telcordia GR-1089 – 600V , 60Asc AC TS600 TS600-170F TIA-968-A Types A & B UL60950 – 600V , 40Asc AC †† TS600-200F GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level Telcordia GR-1089 – 600V , 60Asc AC TS600-400F TSM600 TSM600-250F TIA-968-A Types A & B UL60950 – 600V , 40Asc AC †† GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level Telcordia GR-1089 – 600V , 60Asc AC TSM600-400F TIA-968-A Types A & B UL60950 – 600V , 40Asc AC GR-1089 Port Types 1, 3 and 5 – 1st and 2nd Level Telcordia GR-1089 – 600V , 60Asc AC Notes: * Applies to all products that share the same prefix. † Tested with 230V gas discharge tube primary protector. ‡ Tested with 350V gas discharge tube primary protector. ** See SCD for additional application fault ratings. †† May require additional series resistor to help telecommunication equipment pass Surge 3 (1kV, 10/1000µs). Table T1 — Product Series: Size, Current Rating, Voltage Rating, Typical Resistance TS600 TCF250 TRF250 TS250 TSV250 TSL250 TSM600 TRF600 V Interrupt (V )* 250 250 250 250 250 600 600 MAX AC ITU ITU ITU ITU UL60950 UL60950 GR-1089 GR-1089 GR-1089 GR-1089 GR-1089 GR-1089 GR-1089 Specification Ports 2 and 4 Ports 2 and 4 Ports 2 and 4 Ports 2 and 4 Ports 2 and 4 Ports 1, 3 and 5 Ports 1, 3 and 5 Hold Current (A) 0.055 — 20.0Ω — — — — — 0.080 — 17.0Ω — — 8.0Ω — — 0.100 11.0Ω — — — — — — 0.110 — 7.0Ω — — — — — 0.120 10.5Ω 8.0Ω — — — — — 0.130 — — 9.0Ω 5.5Ω 5.5Ω — — 0.145 7.0Ω 4.5Ω — — — — — 0.150 — — — — — — 8.0Ω 0.160 — — — — — — 6.0Ω 0.170 — — — — — 11.0Ω — 0.183 — 1.3Ω — — — — — 0.184 — 1.9Ω — 1.6Ω — — — 0.200 — — — — — 8.5Ω — 0.250 — — — — — 3.5Ω 3.0Ω 0.400 — — — — — 1.2Ω 1.2Ω Voltage Ratings for Telecommunications and Networking Devices For circuit protection telecommunications devices there are two applicable voltage ratings. These are V Operating and V Interrupt. MAX MAX To help understand the nature of these two different voltage ratings, the following definitions are provided: V Operating : For telecommunications devices, this is the voltage used to obtain component recognition under UL1434. Most circuit protection MAX devices are certified at 60V but can withstand higher V Interrupt conditions. MAX See Table T3 for its V Operating. MAX *V Interrupt : Under specified conditions, this is the highest voltage that can be applied to the device at the maximum current. Devices may trip MAX safely under higher power level cross conditions, as listed above, to assist equipment in meeting the appropriate industry conditions. RoHS 237 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Table T2 — Thermal Derating [Hold Current (A) at Ambient Temperature (°C)] Part Maximum Ambient T emperature -40°C -20°C 0°C 20°C 40°C 50°C 60°C 70°C 85°C Number** Chip* — 250V AC TCF250 TCF250-100T 0.155 0.138 0.119 0.100 0.083 0.073 0.064 0.055 0.042 TCF250-120 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050 TCF250-120T 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050 TCF250-145 0.225 0.199 0.172 0.145 0.119 0.106 0.093 0.080 0.060 TCF250-145T 0.225 0.199 0.172 0.145 0.119 0.106 0.093 0.080 0.060 TCF250-180T 0.269 0.240 0.211 0.180 0.153 0.138 0.123 0.109 0.087 Radial-leaded* — 250V AC TRF250 TRF250-055T 0.085 0.076 0.065 0.055 0.045 0.041 0.035 0.030 0.023 TRF250-055UT 0.085 0.076 0.065 0.055 0.045 0.041 0.035 0.030 0.023 TRF250-080T 0.124 0.110 0.095 0.080 0.066 0.059 0.051 0.044 0.033 TRF250-080U 0.124 0.110 0.095 0.080 0.066 0.059 0.051 0.044 0.033 TRF250-110U 0.171 0.151 0.131 0.110 0.091 0.081 0.071 0.061 0.046 TRF250-120 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050 TRF250-120T 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050 TRF250-120U 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050 TRF250-120UT 0.186 0.165 0.143 0.120 0.099 0.088 0.077 0.066 0.050 TRF250-145 0.225 0.199 0.172 0.145 0.119 0.106 0.093 0.080 0.060 TRF250-145T 0.225 0.199 0.172 0.145 0.119 0.106 0.093 0.080 0.060 TRF250-145U 0.225 0.199 0.172 0.145 0.119 0.106 0.093 0.080 0.060 TRF250-180 0.279 0.247 0.213 0.180 0.147 0.131 0.115 0.099 0.074 ‡ TRF250-183 0.284 0.251 0.217 0.183 0.149 0.133 0.117 0.101 0.075 ‡ TRF250-183U 0.284 0.251 0.217 0.183 0.149 0.133 0.117 0.101 0.075 ‡ TRF250-184 0.286 0.252 0.218 0.184 0.150 0.134 0.118 0.102 0.075 Surface-mount* — 250V AC TS250/TSL250/TSV250 TSL250-080F 0.124 0.110 0.095 0.080 0.066 0.059 0.051 0.044 0.033 TSL250-130F 0.208 0.182 0.156 0.130 0.104 0.091 0.078 0.065 0.045 TS250-130F 0.208 0.182 0.156 0.130 0.104 0.091 0.078 0.065 0.045 TSV250-130F 0.208 0.182 0.156 0.130 0.104 0.091 0.078 0.065 0.045 TSV250-184F 0.286 0.252 0.218 0.184 0.150 0.134 0.118 0.102 0.075 † Radial-leaded — 600V AC TRF600 TRF600-150 0.239 0.209 0.180 0.150 0.121 0.107 0.093 0.079 0.057 TR600-150F-EX 0.239 0.209 0.180 0.150 0.121 0.107 0.093 0.079 0.057 TRF600-160 0.255 0.223 0.192 0.160 0.129 0.114 0.099 0.084 0.061 TRF600-250 0.400 0.350 0.300 0.250 0.198 0.170 0.140 0.117 0.083 TRF600-400 0.640 0.560 0.480 0.400 0.320 0.270 0.230 0.190 0.130 † Surface-mount — 600V AC TS600/TSM600 TS600-170F 0.264 0.230 0.200 0.170 0.140 0.125 0.109 0.094 0.070 TS600-200F 0.310 0.275 0.238 0.200 0.165 0.147 0.128 0.110 0.083 TS600-400F 0.640 0.560 0.480 0.400 0.320 0.270 0.230 0.190 0.130 TSM600-250F 0.400 0.350 0.300 0.250 0.198 0.170 0.140 0.117 0.083 TSM600-400F 0.640 0.560 0.480 0.400 0.320 0.270 0.230 0.190 0.130 * 250V interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements. AC ** Applies to all products which share the same prefix. † 600V interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements. AC ‡ Product is not currently available in a resistance matched or sorted option. RoHS 238 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Figure T1 — Thermal Derating Curve A = TCF250-180T Figure T1 B = All other TCF, TRF, 200 TSM Series Devices B 150 A 100 A 50 B 0 -40 -20 020406080 Device’s Ambient Temperature (˚C) Table T3 — Electrical Characteristics † V I * MAX MAX Part I I Operating Interrupt Interrupt P T ypical Time-to-trip R R R H T D T yp MIN MAX 1MAX Number (A) (A) (V ) (V ) (A) (W) (A) (s) (Ω) (Ω) (Ω) DC RMS Chip* — 250V AC TCF250 TCF250-100T-RB 0.090 0.150 60 250 3.0 0.6 1.0 0.2 15.4 18.0 24.0 TCF250-120 0.120 0.240 60 250 3.0 0.8 1.0 0.9 5.0 9.0 14.0 TCF250-120T 0.120 0.240 60 250 3.0 0.8 1.0 0.6 6.3 12.0 18.0 TCF250-145 0.145 0.290 60 250 3.0 1.0 1.0 2.5 3.0 6.0 14.0 TCF250-145T 0.145 0.290 60 250 3.0 1.0 1.0 1.0 5.0 9.0 14.0 ‡ TCF250-180T 0.180 0.380 60 250 3.0 0.8 1.0 3.4 1.9 3.0 4.2 Radial-leaded* — 250V AC TRF250 TRF250-055T 0.055 0.170 60 250 3.0 0.6 0.28 3.5 15.0 25.0 35.0 TRF250-055UT 0.055 0.170 60 250 3.0 0.6 0.28 3.0 15.0 25.0 35.0 TRF250-080T 0.080 0.160 60 250 3.0 0.6 0.35 4.0 15.0 22.0 33.0 TRF250-080U 0.080 0.160 60 250 3.0 0.6 0.35 2.5 14.0 20.0 33.0 TRF250-110U 0.110 0.220 60 250 3.0 0.6 1.00 0.8 5.0 9.0 16.0 TRF250-120 0.120 0.240 60 250 3.0 0.8 1.00 1.5 4.0 8.0 16.0 TRF250-120T 0.120 0.240 60 250 3.0 0.8 1.00 0.7 7.0 12.0 16.0 TRF250-120T-RA 0.120 0.240 60 250 3.0 0.8 1.00 1.2 7.0 9.0 16.0 TRF250-120T-RC 0.130 0.260 60 250 3.0 0.8 1.00 3.0 5.4 7.5 14.0 TRF250-120T-RF 0.120 0.240 60 250 3.0 0.8 1.00 0.9 6.0 10.5 16.0 TRF250-120T-RH 0.120 0.240 60 250 3.0 0.8 1.00 0.7 9.0 11.0 16.0 TRF250-120T-R1 0.120 0.240 60 250 3.0 0.8 1.00 0.7 6.0 9.0 16.0 TRF250-120T-R2 0.120 0.240 60 250 3.0 0.8 1.00 0.8 8.0 10.5 16.0 TRF250-120U 0.120 0.240 60 250 3.0 0.7 1.00 1.0 6.0 10.0 16.0 TRF250-120UT 0.120 0.240 60 250 3.0 0.7 1.00 0.7 7.0 12.0 16.0 TRF250-145 0.145 0.290 60 250 3.0 0.8 1.00 2.5 3.0 6.0 14.0 * 250V interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements. AC † 600V interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements. AC ‡ Product is not currently available in a resistance matched or sorted option RoHS 239 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. % of Rated Hold and Trip Current PolySwitch Resettable Devices Telecommunications and Networking Devices Table T3 — Electrical Characteristics (Cont’d) † V I * MAX MAX Part I I Operating Interrupt Interrupt P T ypical Time-to-trip R R R H T D T yp MIN MAX 1MAX Number (A) (A) (V ) (V ) (A) (W) (A) (s) (Ω) (Ω) (Ω) DC RMS Radial-leaded* — 250V AC TRF250 TRF250-145-RA 0.145 0.290 60 250 3.0 0.8 1.00 2.5 3.0 6.0 12.0 TRF250-145T 0.145 0.290 60 250 3.0 0.8 1.00 1.5 5.4 7.5 14.0 TRF250-145U 0.145 0.290 60 250 3.0 0.7 1.00 2.0 3.5 6.5 14.0 TRF250-180 0.180 0.650 100 250 10.0 0.9 3.00 0.5 0.8 2.2 4.0 ‡ TRF250-183 0.183 0.685 100 250 10.0 0.9 3.00 0.6 0.8 2.0 3.4 ‡ TRF250-183U 0.183 0.685 100 250 10.0 0.9 3.00 0.6 0.8 2.0 3.4 ‡ TRF250-184 0.184 1.000 100 250 10.0 0.9 3.00 0.5 1.2 2.4 3.1 Surface-mount* — 250V AC TS250/TSL250/TSV250 TSL250-080F 0.080 0.240 80 250 3.0 1.2 1.0 0.8 5.0 11.0 20.0** TSL250-130F 0.130 0.260 60 250 3.0 1.5 1.0 2.0 4.0 8.0 12.0** TS250-130F 0.130 0.260 60 250 3.0 1.1 1.0 0.9 6.5 12.0 20.0** — — 60 600 1.0 — — — — — — TS250-130F-RA 0.130 0.260 60 250 3.0 1.1 1.0 1.4 6.5 9.0 15.0** — — 60 600 1.0 — — — — — — TS250-130F-RB 0.130 0.260 60 250 3.0 1.1 1.0 0.7 9.0 12.0 20.0** — — 60 600 1.0 — — — — — — TS250-130F-RC 0.130 0.260 60 250 3.0 1.1 1.0 1.1 7.0 10.0 17.0** — — 60 600 1.0 — — — — — — TSV250-130F 0.130 0.260 60 250 3.0 1.5 1.0 2.0 4.0 7.0 12.0** TSV250-184F 0.184 0.690 100 250 10.0 0.9 3.0 0.5 1.2 3.0 4.0** † Radial-leaded — 600V AC TRF600 TRF600-150 0.150 0.300 250 600 3.0 1.4 1.0 1.4 6.0 10.0 17.0 TRF600-150-RB 0.150 0.300 250 600 3.0 1.4 1.0 1.0 9.0 12.0 22.0 TRF600-150-R2 0.150 0.300 250 600 3.0 1.4 1.0 1.3 7.0 10.0 17.0 TR600-150F-EX 0.150 0.300 250 600 3.0 1.4 1.0 5.0 6.0 12.0 22.0 TR600-150F-EX-RB 0.150 0.300 250 600 3.0 1.4 1.0 5.0 9.0 12.0 22.0 TRF600-160 0.160 0.320 250 600 3.0 1.7 1.0 7.5 4.0 10.0 18.0 TRF600-160-RA 0.160 0.320 250 600 3.0 1.7 1.0 9.5 4.0 7.0 16.0 TRF600-250 0.250 0.850 250 600 3.0 2.0 3.0 1.0 1.0 4.3 7.0 TRF600-400 0.400 1.000 60 600 3.0 2.4 3.0 4.0 0.95 1.45 1.90 † Surface-mount — 600V AC TS600/TSM600 TS600-170F 0.170 0.400 60 600 3.0 2.5 1.0 10.0 4.0 9.0 18.0 TS600-200F-RA-B-0.5 0.200 0.400 60 600 3.0 2.5 1.0 12.0 4.0 7.5 13.5 TS600-400F 0.400 1.000 60 600 3.0 2.0 3.0 5.0 0.5 1.1 2.0 TSM600-250F 0.250 0.860 250 600 3.0 2.0 3.0 0.8 1.0 3.5 7.0 TSM600-250F-RA 0.250 0.860 250 600 3.0 2.0 3.0 1.0 1.0 3.0 5.0 TSM600-400F 0.400 1.000 250 600 3.0 2.0 3.0 5.0 0.5 1.1 2.0 Notes: I : Hold current: maximum current device will pass without interruption in 20°C still air. H I : Trip current: minimum current that will switch the device from low resistance to high resistance in 20°C still air. T V Operating : Maximum continuous voltage device can withstand without damage at rated current. This voltage is used for component recognition under UL1434. MAX V Interrupt : Maximum voltage that can be safely placed across a device in its tripped state. Devices may trip safely under higher level power cross conditions to assist equipment MAX in meeting I Interrupt : Maximum fault current device can withstand without damage at rated operating voltage. This current is used for component recognition under UL1434. MAX Devices may trip safely under higher level power cross conditions to assist equipment in meeting the appropriate ITU, UL60950 or GR1089 industry requirements. P : Power dissipated from device when in the tripped state in 20°C still air. D R : Minimum resistance of device as supplied at 20°C unless otherwise specified. MIN R : Maximum resistance of device as supplied at 20°C unless otherwise specified. MAX R : Maximum resistance measured one hour post-trip or post-reflow at 20°C. 1MAX * 250V interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements. AC † 600V interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements. AC ‡ Product is not currently available in a resistance matched or sorted option. ** R measured 1 hour post-trip or 24 hours post-reflow at 20°C. 1MAX RoHS 240 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. A C A C A C B B B PolySwitch Resettable Devices Telecommunications and Networking Devices D D E E C toC L L C toC L L Figures T2-T12 — Dimension Figures Figure T2 Figure T3 Figure T4 A A C C A A C C A C A C A C A C A A C C A C AA A AAA CC C CCC AA A AAA CC C CCC A C A C A A A CC C CCC A AA B B B B B B B B C C B B B B BB B B B B B B B BB B B D BB B BBB B D D D D D D D D E E F E E D D E E D DD E E D DD C toCCtoC D DD B D DD A E L LL toL E to C C C CL L L L C toCCtoC E E E E EE L LL L C toC C toC L L LE LE E E EE to to to CC toC C CCC to Cto C CCC L LL L L L L LLL LL D CCtotoC C CCC to to Cto C C toCC L LL L L L E L LLL LL A Figure T5 Figure T6 Figure T7 A A C C A C A C A A A C C C A AA C CC C C C C C C C C B B B B C C C C CC D D CC CCCC D D B B BB BBBB C B B D DD D DD BB BBBB E E E E F F E D D D D E F E E F D D D D C B B B A A B B A F EE E EEE A EE EEEE FF FFFF D DD D DD D DD D DD BB BBBB AA A AAA D D D E E F D B A A E D D E E E A A D DD A G D DD EE E EEE AA A AAA E D A Figure T8 Figure T9 A C A C A C C C C C C C C C CC C C B B C C B B F F F F C C C C CC B B B B B BB B B FF FFFF F F B B F F D D D D E E E E B B D D E E D D E E A A G G F F F F FF A G B B B A G B BB DD D DDD DD D DDDEE EEEE EE EEEE E E D D E D AA A AAA GG G GGG E D A A D A D A D EE EEEE DD D DDD AA A AAA E E E to to to C C C C C C L L L L L L Figure T10 Figure T11 Figure T12 A A A A A A C C C C C C A C A C A C A C A C A C AA A AAA C C C AA A AAA C C C AA A AAA C C C C CC C CC C CC A C B B B B B B B B B B B B B BB BBBB BB BBBB BB B BBB D D D D D D D D D D D D D DD D DDD DD D DDD DD D DDD E E E E E E E C toC E E E E E E L L C Cto toC C C C to to C C C C to to C C L L L L L L L L L L L L to to to toC C toC C toC C C L C L C LC L C LC L L EE E ELEE L EE E E LEE L EE LE EEE C C toC toCto C C C toC CCto toC C C toC CCto toC C C CtoC toCto CC C C toCto CtoCC C C toCto CtoCC LL LLLL LL LLLL LL LLLLLL LLLL LL LLLLLL LLLL A A C C A C A C AA A AAA CC C CCC RoHS 241 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. B B B B B B B B BB D D D D D DD D DD E E E E to to C CC C L LL L C toC C toC L L L L EE E EEE C totoC C to to Cto C toC C CCC CC LL LLLLLL LLLL PolySwitch Resettable Devices Telecommunications and Networking Devices Table T4 — Dimensions & Weights Dimensions in Millimeters (Inches) Device Mass (g) Part Figure A B C D E F G (Only for Reference) Number** Min Max Min Max Min Max Min Max Min Max Min Max Min Max TCF-250V* TCF250-100T 4.6 4.9 4.6 4.9 2.0 2.3 — — — — — — — — T4 0.24 (0.18) (0.19) (0.18) (0.19) (0.08) (0.09) TCF250-120 5.4 5.6 5.4 5.6 2.0 2.3 — — — — — — — — T4 0.28 (0.21) (0.22) (0.21) (0.22) (0.08) (0.09) TCF250-120T 5.4 5.6 5.4 5.6 2.0 2.3 — — — — — — — — T4 0.28 (0.21) (0.22) (0.21) (0.22) (0.08) (0.09) TCF250-145 5.4 5.6 5.4 5.6 2.0 2.5 — — — — — — — — T4 0.28 (0.21) (0.22) (0.21) (0.22) (0.08) (0.10) TCF250-145T 5.4 5.6 5.4 5.6 2.0 2.5 — — — — — — — — T4 0.28 (0.21) (0.22) (0.21) (0.22) (0.08) (0.10) TCF250-180T 6.9 7.1 6.9 7.1 1.3 1.6 — — — — — — — — T4 0.35 (0.27) (0.28) (0.27) (0.28) (0.05) (0.06) TRF250-250V* ‡ TRF250-055T — 5.8 — 9.9 — 4.6 4.7 — 5.0 T2 0.28 (0.23) (0.39) (0.18) (0.19) (0.20) ‡ TRF250-055UT — 4.8 — 9.3 — 3.8 4.7 — 5.0 — — — — — T11 0.13 (0.19) (0.37) (0.15) (0.19) (0.20) ‡ TRF250-080T — 5.8 — 9.9 — 4.6 4.7 — 5.0 — — — — — T2 0.28 (0.23) (0.39) (0.18) (0.19) (0.20) ‡ TRF250-080U — 4.8 — 9.3 — 3.8 4.7 — 5.0 — — — — — T11 0.13 (0.19) (0.37) (0.15) (0.19) (0.20) ‡ TRF250-110U — 5.3 — 9.4 — 3.8 4.7 — 5.0 — — — — — T11 0.13 (0.21) (0.37) (0.15) (0.19) (0.20) ‡ TRF250-120 — 6.5 — 11.0 — 4.6 4.7 — 5.0 — — — — — T3 0.38 (0.26) (0.43) (0.18) (0.19) (0.20) ‡ TRF250-120T — 6.5 — 11.0 — 4.6 4.7 — 5.0 7.0 T3 0.38 (0.26) (0.43) (0.18) (0.19) (0.20) (0.28) ‡ TRF250-120U — 6.0 — 10.0 — 3.8 4.7 — 5.0 — — 6.0 — — T10 0.19 (0.24) (0.39) (0.15) (0.19) (0.20) (0.24) ‡ TRF250-120UT — 6.0 — 10.0 — 3.8 4.7 — 5.0 — — 6.0 — — T10 0.19 (0.24) (0.39) (0.15) (0.19) (0.20) (0.24) ‡ TRF250-145 — 6.5 — 11.0 — 4.6 4.7 — 5.0 — — 7.0 — — T3 0.38 (0.26) (0.43) (0.18) (0.19) (0.20) (0.28) ‡ TRF250-145T 6.5 — 11.0 — 4.6 4.7 — 5.0 — — 7.0 — — T3 0.38 (0.26) (0.43) (0.18) (0.19) (0.20) (0.28) ‡ TRF250-145U — 6.0 — 10.0 — 3.8 4.7 — 5.0 — — 6.0 — — T10 0.19 (0.24) (0.39) (0.15) (0.19) (0.20) (0.24) ‡ TRF250-180 — 9.0 — 12.0 — 3.8 4.7 — 5.0 — — — — — T2 0.35 (0.35) (0.47) (0.15) (0.19) (0.20) ‡ TRF250-183 — 7.5 — 10.5 — 3.8 4.7 — 5.0 — — — — — T2 0.30 (0.29) (0.41) (0.15) (0.19) (0.20) ‡ TRF250-183U 6.5 10.0 3.0 4.7 5.0 T11 0.16 (0.26) (0.39) (0.12) (0.19) (0.20) ‡ TRF250-184 — 7.7 — 10.5 — 4.6 4.7 — 5.0 — — — — — T2 0.32 (0.30) (0.41) (0.18) (0.19) (0.20) TS250/TSL250/TSV250-250V* TSL250-080F 6.7 7.9 2.7 3.7 4.8 5.3 0.2 0.4 2.5 3.1 — — — — T7 2.80 (0.27) (0.31) (0.11) (0.15) (0.19) (0.21) (0.01) (0.02) (0.10) (0.12) TSL250-130F 6.7 7.9 2.7 3.7 4.8 5.3 0.2 0.4 2.5 3.1 — — — — T7 2.80 (0.27) (0.31) (0.11) (0.15) (0.19) (0.21) (0.01) (0.02) (0.10) (0.12) RoHS 242 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Table T4 — Dimensions & Weights (Cont’d) Dimensions in Millimeters (Inches) Device Mass (g) Part Figure A B C D E F G (Only for Reference) Number** Min Max Min Max Min Max Min Max Min Max Min Max Min Max ‡ ‡ TS250-130F 8.5 9.4 — 3.4 — 7.4 0.3 — 3.8 — — — — — T5 3.60 (0.34) (0.37) (0.14) (0.29) (0.01) (0.15) TS250/TSL250/TSV250-250V* TSV250-130F — 6.10 — 6.90 — 3.20 0.56 — — 1.90 1.60 2.30 — — T6 2.80 (0.24) (0.27) (0.13) (0.02) (0.08) (0.07) (0.09) TSV250-184F — 6.10 — 6.90 — 3.20 0.56 — — 1.90 1.60 2.30 — — T6 2.80 (0.24) (0.27) (0.13) (0.02) (0.08) (0.07) (0.09) † TRF600-600V TRF600-150 — 9.0 — 12.5 — 4.6 4.7 — 5.0 — — 9.0 — — T3 0.37 (0.35) (0.49) (0.18) (0.19) (0.20) (0.35) TR600-150F-EX — 13.5 — 12.6 — 6.0 4.7 — 5.0 — — — — — T12 0.80 (0.53) (0.50) (0.18) (0.19) (0.20) ‡ TRF600-160 — 16.0 — 12.6 — 6.0 4.7 — 5.0 — — 10.0 — — T13 0.90 (0.63) (0.50) (0.24) (0.19) (0.20) (0.39) ‡ TRF600-250 — 15.0 14.5 4.6 4.7 5.0 — 10.0 — T3 0.87 (0.59) (0.57) (0.18) (0.19) (0.20) (0.39) ‡ TRF600-400 — 14.8 — 13.1 — 4.6 6.0 — 5.0 — — — — — T12 0.85 (0.58) (0.52) (0.18) (0.27) (0.20) † TS600/TSM600-600V TS600-170F 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 — — T8 23.6 (0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09) TS600-200F 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 — — T8 23.6 (0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09) TS600-400F 18.3 19.4 11.6 12.3 7.2 8.3 1.7 2.4 9.9 10.4 1.5 2.3 — — T8 19.8 (0.72) (0.77) (0.46) (0.49) (0.29) (0.33) (0.07) (0.10) (0.39) (0.41) (0.06) (0.09) TSM600-250F 17.0 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2 (0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12) TSM600-400F 17.0 17.60 11.20 11.70 10.40 11.20 4.80 5.20 2.50 2.80 0.60 1.0 2.2 3.1 T9 31.2 (0.67) (0.69) (0.44) (0.46) (0.41) (0.44) (0.19) (0.20) (0.10) (0.11) (0.02) (0.04) (0.09) (0.12) * 250V interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements. AC ** Applies to all products which share the same prefix. † 600V interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements. AC ‡ Indicates dimension is typical, not minimum. Figures T13-T16 — Figure T13 Typical Time-to-Trip Curves 100 A at 20°C B 10 C TCF250 D A = TCF250-180T 1 A B = TCF250-145/145T C = TCF250-120/120T 0.10 B C D = TCF250-100T D 0.01 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 Fault Current (A) RoHS 243 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. Time–to–Trip (s) PolySwitch Resettable Devices Telecommunications and Networking Devices Figures T13-T16 — Typical Time-to-Trip Curves at 20°C (Cont’d) TRF250 Figure T14 A = TRF250-180/183/183U/184 1000 B = TRF250-145/145U/145T C B D 100 A C = TRF250-120/120U E F D = TRF250-110U/120UT/120T 10 E = TRF250-080T/080U 1 F = TRF250-055T/055UT A B C 0.1 D E F 0.01 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 Fault Current (A) TS250/TSV250/TSL250 Figure T15 A = TSV250-184F B B = TSV250-130F/TSL250-130F C A D C = TS250-130F D = TSL250-080F A B C D 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Fault Current (A) TRF600/TS600/TSM600 Figure T16 1000 A = TRF600-400/TS600-400/ TSM600-400F B C 100 D A B = TRF600-250/TSM600-250F/ E TS600-170F/200F 10 C = TRF600-160 1 D = TR600-150F-EX A B E = TRF600-150 0.1 C D E 0.01 01 2 345 67 Fault Current (A) RoHS 244 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. Time–to–Trip (s) Time–to–Trip (s) Time–to–Trip (s) PolySwitch Resettable Devices Telecommunications and Networking Devices Table T5 — Physical Characteristics and Environmental Specifications Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T and TRF250-184 (0°C t 85°C) TCF250* Physical Characteristics Terminal Material Nickel-plated Copper Foil Environmental Specifications Test Conditions Passive Aging 60°C, 1000 hrs 85°C, 1000 hrs Humidity Aging 85°C, 85% RH, 1000 hrs Thermal Shock 125°C, -55°C (10 Times) Solvent Resistance MIL-STD-202, Method 215F Note: Storage conditions: 40°C (max), 70% RH (max), devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded. TRF250* Physical Characteristics Lead Material Tin-plated Copper, 22AWG Insulating Material Cured Epoxy Polymer Flammability Per IEC 695-2-2 Needle Flame Test for 20 s Soldering Characteristics ANSI/J-STD-002, Category 3 Solder Heat Withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: Can Withstand 10s at 260°C±5°C Note: Devices are not intended to be placed through a reflow process. Environmental Specifications Test Conditions Passive Aging 60°C, 1000 hrs 85°C, 1000 hrs Humidity Aging 85°C, 85% RH, 1000 hrs Thermal Shock 125°C, -55°C (10 Times) Solvent Resistance MIL-STD-202, Method 215F Note: Storage conditions: 40°C (max), 70% RH (max), devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded. TS250/TSV250/TSL250* Physical Characteristics Terminal Material Tin-plated Brass, Nickel Under-plating Soldering Characteristics EIC 60068-2-58 Environmental Specifications Test Conditions Passive Aging 60°C, 1000 hrs 85°C, 1000 hrs Humidity Aging 85°C, 85% RH, 500 hrs Thermal Shock 125°C, -55°C (10 Times) Solvent Resistance MIL-STD-202, Method 215F Note: Storage conditions: 40°C (max), 70% RH (max), devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded. RoHS 245 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Table T5 — Physical Characteristics and Environmental Specifications (Cont’d) Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T and TRF250-184 (0°C to 85°C) TRF600† Physical Characteristics Lead Material Tin-plated Copper, 22AWG ‡ Insulating Material Cured Epoxy Polymer Flammability Per IEC 695-2-2 Needle Flame Test for 20s Soldering Characteristics ANSI/J-STD-002, Category 3 Solder Heat Withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A, Condition B: Can Withstand 10 s at 260°C±5°C Note: Devices are not intended to be placed through a reflow process. Environmental Specifications Test Conditions Passive Aging 60°C, 1000 hrs 85°C, 1000 hrs ‡ Humidity Aging 85°C, 85% RH, 1000 hrs Thermal Shock 125°C, -55°C (10 Times) Solvent Resistance MIL-STD-202, Method 215F Note: Storage conditions: 40°C (max), 70% RH (max) devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded. TS600† Physical Characteristics Terminal Material Tin-plated Brass Insulating Material Nylon Resin (UL94V-0), 1000V Dielectric Rating Flammability IEC 695-2-2 Needle Flame Test for 20 s Soldering Characteristics ANSI/J-STD-002, Category 3 Solder Heat Withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A Environmental Specifications Test Conditions Passive Aging 60°C, 1000 hrs 85°C, 1000 hrs Humidity Aging 85°C, 85% RH, 1000 hrs Thermal Shock 125°C, -55°C (10 Times) Solvent Resistance MIL-STD-202, Method 215F Note: Storage conditions: 40°C (max), 70% RH (max), devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded. * 250V interrupt products may help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements. AC † 600V interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements. AC ‡ Excluding TRF600-150 and TRF600-400, which have a coating that is not rated for dielectric withstand and can withstand 500h at 85°C/85% RH or 1000h at 60°C/90% RH. RoHS 246 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Table T5 — Physical Characteristics and Environmental Specifications (Cont’d) Operating temperature range for all listed products is -40°C to 85°C, except for TRF250-080T and TRF250-184 (0°C to 85°C) TSM600† Physical Characteristics Terminal Material Tin-plated Brass Insulating Material Nylon Resin (UL94V-0), 1000V Dielectric Rating Flammability IEC 695-2-2 Needle Flame Test for 20 s Soldering Characteristics EIC60068-2-58, Method 7 Solder Heat Withstand IEC-STD 68-2-20, Test Tb, Section 5 Method 1A Environmental Specifications Test Conditions Passive Aging 60°C, 1000 hrs 85°C, 1000 hrs Humidity Aging 85°C, 85% RH, 1000 hrs Storage Humidity Per IPC/JEDEC J-STD-020A Level 2a Thermal Shock 125°C, -55°C (10 Times) Solvent Resistance MIL-STD-202, Method 215J Note: Storage conditions: 40°C (max), 70% RH (max) devices should remain in original sealed bag prior to use. Devices may not meet specified values if these storage conditions are exceeded. † 600V interrupt products may help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements. AC Table T6 — Packaging and Marking Information Part Bag Tape and Reel Standard Package Part Marking Agency Recognition Number** Quantity Quantity Quantity Chip* — 250V AC TCF250 TCF250-100T 2,500 — 10,000 — — TCF250-120 2,500 — 10,000 — — TCF250-120T 2,500 — 10,000 — — TCF250-145 2,500 — 10,000 — UL TCF250-145T 2,500 — 10,000 — UL TCF250-180T 2,500 — 10,000 — UL Radial-leaded* — 250V AC TRF250 TRF250-055T 500 — 10,000 — — TRF250-055UT 500 — 10,000 — — TRF250-080U 500 — 10,000 — UL, CSA, TÜV TRF250-080T 500 — 10,000 08F UL, CSA, TÜV TRF250-110U 500 — 10,000 — UL, CSA, TÜV TRF250-120 500 — 10,000 20F UL, CSA, TÜV TRF250-120-2 — 1,500 7,500 20F UL, CSA, TÜV TRF250-120T 500 — 10,000 20F UL, CSA, TÜV TRF250-120T-2 — 1,500 7,500 20F UL, CSA, TÜV TRF250-120U 500 — 10,000 20F UL, CSA, TÜV TRF250-120U-2 — 1,500 7,500 20F UL, CSA, TÜV TRF250-120UT 500 — 10,000 20F UL, CSA, TÜV RoHS 247 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Table T6 — Packaging and Marking Information (Cont’d) Part Bag Tape and Reel Standard Package Part Marking Agency Recognition Number** Quantity Quantity Quantity Radial-leaded* — 250V AC TRF250 TRF250-145 500 — 10,000 45F UL, CSA, TÜV TRF250-145-2 — 1,500 7,500 45F UL, CSA, TÜV TRF250-145T 500 — 10,000 45F UL, CSA, TÜV TRF250-145T-2 — 1,500 7,500 45F UL, CSA, TÜV TRF250-145U 500 — 10,000 45F UL, CSA, TÜV TRF250-145U-2 — 1,500 7,500 45F UL, CSA, TÜV TRF250-180 500 — 10,000 80F UL, CSA, TÜV TRF250-180-2 — 1500 7,500 80F UL, CSA, TÜV TRF250-183 500 — 10,000 83F UL, CSA, TÜV TRF250-183-2 — 1,500 7,500 83F UL, CSA, TÜV TRF250-183U 500 — 10,000 — UL, CSA, TÜV TRF250-184 500 — 10,000 84F UL, CSA, TÜV Surface-mount* — 250V AC TS250/TSL250/TSV250 TSL250-080F-2 — 1,500 7,500 T08 UL, CSA,TÜV TSL250-130F-2 — 1,500 7,500 T13 — TS250-130F-2 — 1,500 7,500 T13 UL, CSA, TÜV TSV250-130F 2500 — 10,000 T13V UL, CSA, TÜV TSV250-130F-2 — 1,200 6,000 T13V UL, CSA, TÜV TSV250-184F 2500 — 10,000 T18V UL † Radial-leaded — 600V AC TRF600 TRF600-150 500 — 10,000 150F UL, CSA, TÜV TRF600-150-2 — 1,500 7,500 150F UL, CSA, TÜV TR600-150F-EX 500 — 10,000 150F UL, CSA TR600-150F-EX-2 — 600 3,000 150F UL, CSA TRF600-160 500 — 10,000 160F UL, CSA, TÜV TRF600-160-2 — 600 3,000 160F UL, CSA, TÜV TRF600-250 500 — 10,000 250F UL, CSA, TÜV TRF600-400 500 — 10,000 400F UL, CSA, TÜV † Surface-mount — 600V AC TS600/TSM600 TS600-170F-2 — 300 900 T20 UL, CSA TS600-200F-RA-2 — 300 900 T20 UL, CSA TS600-400F-2 — 300 900 T40 UL, CSA TSM600-250F-2 — 200 600 TSM600 UL, CSA TSM600-250F-RA-2 — 200 600 TSM600 UL, CSA TSM600-400F-2 — 200 600 TSM600-4 UL Notes: * 250V interrupt products are designed to help equipment pass ITU K.20, K.21 and K.45 recommendations and Telcordia GR-1089 Port Type 2 and 4 requirements. AC ** Applies to all products which share the same prefix. † 600V interrupt products are designed to help equipment pass UL60950, TIA-968-A and GR1089 Port Type 1, 3 and 5 requirements. AC Agency Recognition UL File # E74889 CSA File # 78165C TÜV Per IEC60730-1 Certificate # for individual products available upon request. RoHS 248 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Table T7 — Recommended Pad Layouts for Surface-mount PolySwitch Telecommunications and Networking Devices in Millimeters (Inches) Nominal Device A B C D E F G Figure TS250 (All) 4.60 1.80 6.10 — — — — T17 (0.180) (0.070) (0.240) — — — — TSV250 (All) 2.29 2.41 6.35 3.43 — — — T18 (0.090) (0.095) (0.250) (0.135) — — — TSL250 (All) 3.60 1.80 5.50 — — — — T17 (0.140) (0.070) (0.220) — — — — TS600 (All) 10.42 3.30 3.35 — — — — T17 (0.410) (0.130) (0.132) — — — — TSM600 (All) 5.20 17.80 5.54 6.75 2.08 3.12 8.39 T19 (0.205) (0.701) (0.218) (0.266) (0.082) (0.123) (0.331) FigureT17 Figure T18 Figure T19 B BB A AA D DD A AA A AA A AA E G EEGG B BB B BB F FF B BB CB CB CB C CC C CC D DD Solder Reflow and Rework Recommendations for PolySwitch Telecommunications Surface-Mount Devices Profile Feature Pb-Free Assembly Figure T20 Average ramp up rate (Ts to Tp) 3°C/s max MAX Preheat • Temperature min (Ts ) 150°C MIN • Temperature max (Ts ) 200°C MAX • Time (ts to ts ) 60-180 s MIN MAX Time maintained above: • Temperature (T ) 217°C L • Time (t ) 60-150 s L Peak/Classification temperature (Tp) 260°C Time within 5°C of actual peak temperature Time (tp) 20-40 s Ramp down rate 6°C/s max Time 25°C to peak temperature 8min max Note: All temperatures refer to topside of the package, measured on the package body surface. Solder Reflow • Recommended reflow method: IR, vapor phase oven, hot air oven. • Surface-mount devices are not intended to be wave soldered to the bottom side of the board. • Recommended maximum paste thickness of 0.25mm (0.010in). • Devices can be cleaned using standard industry methods and solvents. Rework • If a device is removed from the board, it should be discarded and replaced with a new device. RoHS 249 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Wave Soldering and Rework Recommendations for PolySwitch Telecommunications Radial-Leaded Devices Figure T21 Recommended Wave Soldering 300 10s • Soldering temperature profile 245˚C ... 260˚C 250 200 Temperature characteristic at component terminal with dual wave soldering 150 100˚C ... 130˚C Rework 100 Forced cooling 50 • If a device is removed from the board, it should be discarded and replaced with a new device 0 050 100 150 200 250 Time (s) Table T8 — TRF250/TRF600 Tape and Reel Specifications TRF250/TRF600 devices are available in tape and reel packaging per EIA 468-B standard. Dimension Description EIA Mark IEC Mark Dimension (mm) Tolerance Carrier Tape Width W W 18 -0.5/+1.0 Hold Down Tape Width W W 5 Min 4 0 Top Distance between Tape Edges W W 3 Max 6 2 Sprocket Hole Position W W 9 -0.5/+0.75 5 1 Sprocket Hole Diameter D D 4 ±0.2 0 0 Abcissa to Plane (Straight Lead) H H 18.5 ±3.0 Abcissa to Plane (Kinked Lead)* H H 16 -0.5/+0.6 0 0 Abcissa to Top H H 38.5 Max 1 1 Overall Width with Lead Protrusion — C 43.2 Max 1 Overall Width without Lead Protrusion — C 42.5 Max 2 Lead Protrusion L I 1.0 Max 1 1 Protrusion of Cut-out L L 11 Max Protrusion beyond Hold Down Tape I I Not Specified — 2 2 Sprocket Hole Pitch P P 12.7 ±0.3 0 0 Device Pitch (TRF250 and TRF600-150) — — 12.7 — Device Pitch (TRF600-160 - TRF600-400) — — 25.4 — Pitch Tolerance — — 20 Consecutive ±1 Tape Thickness t t 0.9 Max Tape Thickness with Splice* t — 2.0 Max 1 Splice Sprocket Hole Alignment — — 0 ±0.3 Body Lateral Deviation Dh Dh 0 ±1.0 Body Tape Plane Deviation Dp Dp 0 ±1.3 Lead Spacing Plane Deviation DP P 0 ±0.7 1 1 Lead Spacing* F F 5.08 ±0.6 Reel Width w w 56 Max 2 Reel Diameter a d 370 Max Space between Flanges Less Device w — 4.75 ±3.25 1 Arbor Hole Diameter c f 26 ±12.0 Core Diameter n h 80 Max Box — — 56/372/372 Max Consecutive Missing Pieces* — — 3 Max — Empty Places per Reel* — — Not Specified — * Differs from EIA specification. RoHS 250 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. Temperature (˚C) PolySwitch Resettable Devices Telecommunications and Networking Devices Figure T22 — EIA Referenced Taped Component Dimensions for PolySwitch Telecommunications Radial-Leaded Devices p p h h Reference Plane H P C H 1 1 2 1 F C H 1 AB H 0 L W 5 W 4 W I 2 L 1 P D Direction of Unreeling 0 0 Cross section A-B t Figure T23 — Reel Dimensions for PolySwitch Telecommunications Radial-Leaded Devices Reel Upper Side n Tape Direction of a Unreeling Lower Side c w 1 Cross Section w 2 Optional Shape: Circular or Polygonal RoHS 251 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Table T9 — TS Tape and Reel Specifications TS devices are packaged per EIA 481 and EIA 481-2 standards. TS250/TSL250/TSV250 Dimension TS250 TSV250 TSL250 EIA Mark Dimension (mm) Tolerance (mm) Dimension (mm) Tolerance (mm) Dimension (mm) Tolerance (mm) Description Carrier Tape Width W 16 ±0.30 16.0 ±0.30 16 ±0.30 Sprocket Hole Pitch P 4.0 ±0.10 4.0 ±0.10 4.0 ±0.10 0 P 12.0 ±0.10 8.0 ±0.10 8.0 ±0.10 1 P 2.0 ±0.10 2.0 ±0.10 2.0 ±0.10 2 A 6.9 ±0.23 5.5 ±0.10 5.5 ±0.10 0 B 9.6 ±0.15 6.2 ±0.10 7.9 ±0.10 0 B max 12.1 — 8.0 — 9.2 — 1 Sprocket Hole Diameter D 1.5 -0/+0.1 1.55 ±0.05 1.55 ±0.05 0 F 7.5 ±0.10 7.5 ±0.10 7.5 ±0.10 E 1.75 ±0.10 1.75 ±0.10 1.75 ±0.10 1 E min 14.25 — — — — — 2 Tape Thickness T max 0.4 — 0.45 — 0.35 — Tape Thickness With T max 0.1 — 0.1 — 0.1 — 1 K 3.4 ±0.15 7.0 ±0.10 3.70 ±0.10 0 Splice Cover Tape Thickness Leader min 300 — 390 — 390 — Trailer min 300 — 160 — 160 — Reel Dimensions Reel Diameter A max 340 — 340 — 340 — Core Diameter N min 50 — 50 — 50 — Space between Flanges-less Device W 16.4 -0/+2.0 16.4 -0/+2.0 16.4 -0/+2.0 1 Reel Width W max 22.4 — 22.4 — 22.4 — 2 TS600 Dimension EIA Mark Dimension (mm) Tolerance (mm) Description Carrier Tape Width W 32 ±0.3 Sprocket Hole Pitch P 4.0 ±0.1 0 P 16 ±0.1 1 P 2.0 ±0.1 2 A 10 ±0.1 0 B 19.2 ±0.1 0 B max 21.6 1 Sprocket Hole Diameter D 1.5 -0/+1.0 0 F 14.2 ±0.1 E 1.75 ±0.1 1 E min 28.4 ±0.1 2 Tape Thickness T max 0.50 ±0.5 Tape Thickness with Splice T max 0.1 1 K 13.2 ±0.1 0 Leader min 390 Trailer min 160 Reel Dimensions Reel Diameter A max 360 Core Diameter N min 50 Space between Flanges-less Device W 32.4 -0/+2.0 1 Reel Width W max 40 2 RoHS 252 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Table T9 — TS Tape and Reel Specifications (Cont’d) TS devices are packaged per EIA 481 and EIA 481-2 standards. TSM600 Dimension EIA Mark Dimension (mm) Tolerance (mm) Description Carrier Tape Width W 32 ±0.3 Sprocket Hole Pitch P 4.0 ±0.1 0 P 24 ±0.1 1 P 2.0 ±0.1 2 A 11.2 ±0.1 0 B 17.8 ±0.1 0 B max 23.45 1 Sprocket Hole Diameter D 1.5 -0/+1.0 F 14.2 ±0.1 E 1.74 ±0.1 1 E max 28.4 ±0.1 2 Tape Thickness T max 0.5 ±0.5 Tape Thickness with Splice T max 0.1 1 K 11.9 ±0.1 0 Leader min 390 Trailer min 160 Reel Dimensions Reel Diameter A max 360 Core Diameter N min 50 Space between Flanges-less Device W 32.4 -0/+2.0 1 Reel Width W max 40 2 Figure T24 — EIA Referenced Taped Component Dimensions for PolySwitch Telecommunications and Networking Devices Embossment P 0 T D P 0 2 E 1 Cover Tape A 0 F W E 2 K 0 B B 0 1 T P 1 1 Center Lines of Cavity RoHS 253 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Figure T25 — EIA Referenced Reel Dimensions for PolySwitch Telecommunications and Networking Devices W (Measured at Hub) 2 A N (Hub Dia.) Cover Tape W (Measured at Hub) 1 Carrier Tape Embossed Cavity PolySwitch Telecommunications and Networking Resistance-Sorted and Resistance-Matched Devices Most TCF, TRF and TS devices are available in resistance-sorted and/or resistance-matched versions. Resistance-sorted Devices Resistance-sorted devices (part number suffix “Rx” , where x = 1, 2, A, B, C, F, etc.) are supplied with resistance values that are within specified segments of the device’s full range of resistance. Feature • Narrow resistance range. Benefits • Can help provide greater flexibility for design engineers. • Lower resistance devices can help provide increased loop length on line card designs. • Higher resistance devices may help provide greater protection by offering faster time-to-trip. Resistance-matched Devices Resistance-matched devices are supplied such that all parts in one particular package (or reel) are within 0.5Ω of each other (1.0Ω for TRF250-080T devices). Individual matched packages are supplied from the full resistance range of the specified device. Feature • Tighter resistance balance between any two parts in a package. Benefits • Resistance-matched devices may help reduce the tip-ring resistance differential, reducing the possibility of line imbalance. RoHS 254 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Part Numbering System for PolySwitch Radial-Leaded Telecommunications and Networking Devices TRF*250 -120 T -RA -B-0.5 -2 TRF*250 -120 T -RA -B-0.5 -2 Packaging 2 = Tape and Reel Packaging 0.130 = Special Lead Length in Inches 2 = Tape and Reel (Blank) = Bulk 0.130 = Special Lead Length in Inches TRF*250 -120 T -RA -B-0.5 -2 (Blank) = Bulk B-x.x = Resistance Matched in Bins of x.xΩ (Optional) B-x.x = Resistance Matched in Bins of x.xΩ (Optional) Rx = Resistance Range (Optional) Packaging 2 = Tape and Reel Rx = Resistance Range (Optional) Modifier (Optional) 0.130 = Special Lead Length in Inches U = Uncoated (Blank) = Bulk Modifier (Optional) S = Straight Lead U = Uncoated T = Fast Trip Device B-x.x = Resistance Matched in Bins of x.xΩ (Optional) S = Straight Lead T = Fast Trip Device Hold Current (mA) Rx = Resistance Range (Optional) Hold Current (mA) Product Series (TRF250, TRF600) Modifier (Optional) * F = RoHS compliant, ELV compliant U = Uncoated Product Series (TRF250, TRF600) S = Straight Lead * F = RoHS compliant, ELV compliant T = Fast Trip Device Hold Current (mA) Part Numbering System for PolySwitch Surface-mount Telecommunications and Product Series (TRF250, TRF600) Networking Devices * F = RoHS compliant, ELV compliant TSx -200 F -RA -B-0.5 -2 TSx -200 F -RA -B-0.5 -2 Packaging 2 = Tape and Reel Packaging (Blank) = Bulk 2 = Tape and Reel (Blank) = Bulk TSx -200 F -RA -B-0.5 -2 B-x.x = Resistance Matched in Bins of x.xΩ (Optional) B-x.x = Resistance Matched in Bins of x.xΩ (Optional) Rx = Resistance Range (Optional) Packaging Rx = Resistance Range (Optional) F = RoHS Compliant, ELV Compliant 2 = Tape and Reel (Blank) = Bulk F = RoHS Compliant, ELV Compliant Hold Current (mA) B-x.x = Resistance Matched in Bins of x.xΩ (Optional) Hold Current (mA) Product Series (TS250, TSV250, TSL250, TS600, TSM600) Rx = Resistance Range (Optional) Product Series (TS250, TSV250, TSL250, TS600, TSM600) F = RoHS Compliant, ELV Compliant TCF*250 -120 T -RA -B-0.5 Hold Current (mA) TCF*250 -120 T -RA -B-0.5 Product Series (TS250, TSV250, TSL250, TS600, TSM600) Part Numbering System for Chip PolySwitch Telecommunications and B-x.x = Resistance Matched in Bins of x.xΩ (Optional) Networking Devices B-x.x = Resistance Matched in Bins of x.xΩ (Optional) Rx = Resistance Range (Optional) Rx = Resistance Range (Optional) TCF*250 -120 T -RA -B-0.5 Modifier (Optional) T = Fast Trip Device Modifier (Optional) T = Fast Trip Device Hold Current (mA) B-x.x = Resistance Matched in Bins of x.xΩ (Optional) Hold Current (mA) Product Series Rx = Resistance Range (Optional) * F = RoHS compliant, ELV compliant Product Series Modifier (Optional) * F = RoHS compliant, ELV compliant T = Fast Trip Device Hold Current (mA) Product Series * F = RoHS compliant, ELV compliant RoHS 255 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc. PolySwitch Resettable Devices Telecommunications and Networking Devices Warning : • Users should independently evaluate the suitability of and test each product selected for their own application. • Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame. • These devices are intended for protection against damage caused by occasional overcurrent or overtemperature fault conditions and should not be used when repeated fault conditions or prolonged trip events are anticipated. • Contamination of the PPTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices. • Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal and mechanical procedures for electronic components. • PPTC devices are not recommended for installation in applications where the device is constrained such that its PTC properties are inhibited, for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion. • Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of the device. Notice: Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications.  Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, military, aerospace, medical, life-saving, life- sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation.  Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation.  Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation.  The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. RoHS 256 RoHS Compliant, ELV Compliant Specifications subject to change without notice. ©2018 Littelfuse, Inc.

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the DECASMDC050F/60-2?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

PTC Resettable Fuse 10A(hold) 18.5A(trip) 16VDC 3.6W 7s 0.0034Ohm Radial 16.51 X 3 X 25.7mm AGR1000

product

PTC Resettable Fuse 11A(hold) 20.3A(trip) 16VDC 3.7W 7.5s 0.0033Ohm Radial 17.5 X 3 X 26.5mm AGR1100

product

PTC Resettable Fuse 4A(hold) 7.6A(trip) 16VDC 2.5W 2s 0.0186Ohm Radial 8.9 X 3 X 14.1mm AGR400

product

PTC Resettable Fuse 5A(hold) 9.4A(trip) 16VDC 2.7W 2.5s 0.014Ohm Radial 10.4 X 3 X 15.6mm AGR500

product

PTC Resettable Fuse 6A(hold) 10.7A(trip) 16VDC 2.8W 3.5s 0.0095Ohm Radial 10.7 X 3 X 18.4mm AGR600

product

PTC Resettable Fuse 7A(hold) 13.2A(trip) 16VDC 3W 4s 0.0066Ohm Radial 11.2 X 3 X 21mm AGR700