MEAN WELL MPQ-120C
Specifications
Manufacturer
MEAN WELL
Manufacturers Part #
MPQ-120C
Series
120W Medical
Factory Pack Quantity
24
Cooling Method
Air-Cooled, Convection
Dimensions
7.00 x 4.25 x 1.40"
Efficiency
71%
Industry
Medical
Input Type
AC
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis
Number of Outputs
4
Operating Temperature
- 20 to + 70°C
Output Amps 1
10 A
Output Amps 2
1 A
Output Amps 3
2.1 A
Output Amps 4
0.6 A
Output Voltage V1 Nominal
5 VDC
Output Voltage V2 Nominal
15 VDC
Output Voltage V3 Nominal
-5 VDC
Output Voltage V4 Nominal
-15 VDC
Package Type
Open Frame
Power
120 W
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
1~4 Output Medical Type 120W M edical series Features Universal AC input / Full range Low leakage current <180 A Protections: Short circuit / Overload / Over voltage UL60601-1 medical safety approved With power good and fail signal output (Optional) 100% full load burn-in test Fixed switching frequency at 45KHz 3 years warranty EN60601-1 IEC60601-1 Specification AC INPUT VOLTAGE TEMP. COEFFICIENT 90~264 VAC, 47~440Hz / 127~370VDC. 0.04%/ on all outputs at full load between 0~50 of ambient temperature. AC INPUT CURRENT (Typ.) VIBRATION Maximum input current 2.9A at 115VAC, 60Hz or 2G of acceleration, vibrating frequency adjust from 10Hz ~500Hz within a 1.7A at 230VAC, 60Hz with 100% output load. 10-minute cycle. 6 testing cycles (60 minutes) each along X, Y, Z axes. INRUSH CURRENT (Typ.) SAFETY STANDARDS Inrush current is less than 22A at 115VAC or less than Medical : UL60601-1, TUV EN60601-1, IEC60601-1 approved 45A at 230VAC under cold start conditions. Limiting Commercial : Also design refer to UL60950-1, TUV EN60950-1 provided by internal thermistors. WITHSTAND VOLTAGE SETUP, RISE TIME 4000VAC between input and output MPS-120: 800ms, 20ms / 230VAC at full load 1500VAC between input and F.G. 2000ms, 50ms / 115VAC at full load 500VAC between output and F.G. MPD,T,Q-120:500ms, 20ms / 230VAC at full load 1200ms, 50ms / 115VAC at full load ISOLATION RESISTANCE >100M Ohms for I/P-O/P, I/P-FG, O/P-FG by using 500VDC test voltage. HOLD-UP TIME (Typ.) 80ms / 230VAC at full load EMI COMPLIANCE 14ms / 115VAC at full load EMI Specifications Compliance Level Conducted & Radiation EN55011, Class B LEAKAGE CURRENT EN55022, Class B Leakage current is less than 180 A at 264VAC Harmonic distortion EN61000-3-2 Voltage flicker EN61000-3-3 DC OUTPUT ADJ. RANGE DC output voltage (or Ch1 of multiple output models) EMS COMPLIANCE can be adjusted between -5%~+10% rated output Compliance Level EMS Specification voltage by potential meter. EN61000-4-2, Level 3, 8KV ESD air EN61000-4-2, Level 2, 4KV ESD contact OVERLOAD PROTECTION EN61000-4-3, RF field susceptibility Level 2, 3V/m Fully protected against short circuit and output overload. Level 3, 10V/m The hiccup type protection will be activated at 110~150% EFT(Electrical Fast Transient)/Burst EN61000-4-4, Level 2, 1KV/5KHz (For MPD,T,Q-120),120~160%(For MPS-120) rated load Level 3, 2KV/5KHz and recovers automatically after fault condition is removed. Lightning/Surge EN61000-4-5, Level 4, 2KV/Line-Line 4KV/Line-Earth OVER VOLTAGE PROTECTION Conducted RF susceptibility EN61000-4-6, Level 2, 3Vrms/m Provided on output channel 1 only at 115%~135% Level 3, 10Vrms/m rated output voltage. (120%~140% for MPS-120-15/24/48). Magnetic field immunity EN61000-4-8, Level 2, 3A/m Output will be shut down when this protection is activated. Level 3, 10A/m Voltage dip, interruption EN61000-4-11,Compliance POWER GOOD / FAIL SIGNAL (OPTIONAL) Digital phone carrier immunity ENV50204, Level 2, 3V/m, 900MHz TTL logic high for power good and TTL low for Level 3, 10A/m, 900MHz power fail. When the output voltage reaches 90% of MTBF rated value, a +5V TTL signal will be sent out with a 262,100 hours min. at full load and 25 of ambient temperature, 10~500ms delay; At least 1ms before the output calculated per MIL-HDBK-217F. voltage goes below 90% of the rated value, the TTL signal will be turned off. DIMENSION (L*W*H) * MPS-120-3.3 does not have this optional function. 177.8x107.95x35.5mm or 7"x4.25"x1.4" WORKING TEMP. PACKING Whole series can operate from -20~70 . Please refer 0.55Kg; 24pcs/14.5Kg/0.99CUFT to the derating curves. WORKING HUMIDITY 20~90% RH non-condensing. STORAGE TEMP., HUMIDITY -40~+85 , 10~90% RH File Name:120W MEDICAL-SPEC 2011-03-31 1~4 Output Medical Type 120W M edical series Output Chart OUTPUT CURRENT RIPPLE & NOISE VOLTAGE OUTPUT RATED LINE LOAD PEAK LOAD MODEL (Max.) TOLERANCE EFFICIENCY VOLTAGE CURRENT MINIMUM CONVECTION WITH FAN REGULATION REGULATION WITH 25CFM FAN (Note 2) (Note 3) LOAD (25CFM) (max.) (Note 4) MPS-120-3.3 3.3V 24A 0A 16A 24A 26A 80mVp-p 3.0% 1.0% 3.0% 68% MPS-120-5 5V 22A 0A 14.7A 22A 26A 80mVp-p 3.0% 1.0% 3.0% 73% MPS-120-12 12V 10A 0A 6.7A 10A 11A 100mVp-p 2.0% 1.0% 2.0% 77% MPS-120-15 15V 8A 0A 5.3A 8A 8.8A 100mVp-p 2.0% 1.0% 2.0% 79% MPS-120-24 24V 5A 0A 3.3A 5A 5.5A 120mVp-p 2.0% 1.0% 2.0% 81% MPS-120-48 48V 2.5A 0A 1.7A 2.5A 2.8A 120mVp-p 2.0% 1.0% 2.0% 82% MPD-120A 5V 10A 2A 7.3A 10A 12A 80mVp-p 2.0% 0.5% 0.5% 75% 12V 5A 0.5A 3.6A 5A 6A 120mVp-p 7.0% 2.0% 3.5% MPD-120B 5V 10A 2A 7A 10A 12A 80mVp-p 2.0% 0.5% 0.5% 76% 24V 2.9A 0.3A 1.9A 2.9A 3.2A 250mVp-p 8.0% 2.0% 4.0% MPT-120A 5V 10A 2A 7.3A 10A 12A 80mVp-p 2.0% 0.5% 1.0% 12V 4.8A 0.4A 3.5A 4.8A 5.8A 120mVp-p +8,-6% 1.5% 3.5% 72% -5V 0.6A 0A 0.3A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% MPT-120B 5V 10A 2A 7.3A 10A 12A 80mVp-p 2.0% 0.5% 1.0% 12V 4.4A 0.4A 3.2A 4.4A 5.3A 120mVp-p 6.0% 1.5% 3.5% 73% -12V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% MPT-120C 5V 10A 2A 7A 10A 11A 80mVp-p 2.0% 0.5% 1.0% 15V 4A 0.4A 2.6A 4A 4.4A 150mVp-p +6,-7% 2.0% 3.5% 72% -15V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% MPT-120D 5V 10A 2A 7.3A 10A 12A 80mVp-p 2.0% 0.5% 1.0% 24V 2.2A 0.4A 1.6A 2.2A 2.64A 300mVp-p +8,-6% 3.0% +4,-3% 74% 12V 0.6A 0A 0.4A 0.6A 1A 120mVp-p 5.0% 0.5% 1.0% MPQ-120B 5V 10A 2A 7.3A 10A 11A 80mVp-p 2.0% 0.5% 0.5% 12V 4.2A 0.5A 3.1A 4.2A 5A 120mVp-p 6.0% 1.5% 3.5% 71% -5V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% -12V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% MPQ-120C 5V 10A 2A 7.3A 10A 11A 80mVp-p 2.0% 0.5% 0.5% 15V 3.2A 0.5A 2.4A 3.2A 3.8A 150mVp-p +6,-7% 2.0% 3.5% 71% -5V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% -15V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% MPQ-120D 5V 10A 2A 7A 10A 11A 80mVp-p 2.0% 0.5% 0.5% 12V 1A 0.2A 0.7A 1A 1.1A 150mVp-p +8,-6% 2.0% 3.5% 74% 24V 2.1A 0.3A 1.4A 2.1A 2.3A 300mVp-p 8.0% 2.0% 3.5% -12V 0.6A 0A 0.3A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% MPQ-120E 5V 10A 2A 7.3A 10A 11A 80mVp-p 2.0% 0.5% 0.5% 12V 3A 0.5A 2.3A 3A 3.3A 120mVp-p 6.0% 2.0% 3.0% 73% 15V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 8.0% 2.0% 3.0% 24V 0.6A 0A 0.4A 0.6A 1A 80mVp-p 5.0% 0.5% 1.0% Notes : 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 6. Heat Sink HS1,HS2 can not be shorted. File Name:120W MEDICAL-SPEC 2011-03-31 1~4 Output Medical Type 120W M edical series Mechanical Specification Unit:mm 177.8[7"] 165.1 [6.5"] CN1 5 4 3 2 1 13 12 11 10 HS1,HS2 can not be shorted HS1 9 8 7 6 HS2 5 4 3 2 1 +V ADJ CN2 4- 3.96[0.156"] FAN 2[0.078"] max. Pin Assignment AC Input Connector (CN1) : Molex 5273-05 or equivalent Pin No. MPS-120 MPD-120 MPT-120 MPQ-120 Mating Housing Terminal 1 FG FG FG FG 2,4 No Pin No Pin No Pin No Pin Molex 5195 Molex 5194 or equivalent or equivalent 3 AC/N AC/N AC/N AC/N 5 AC/L AC/L AC/L AC/L DC Output Connector (CN2) : Molex 5273-13 or equivalent Pin No. MPS-120 MPD-120 MPT-120 MPQ-120 Mating Housing Terminal 1 +V V1 V1 V1 2 +V V1 V1 V1 3 +V V1 V1 V1 4 -V COM COM COM 5 -V COM COM COM 6 -V COM COM COM Molex 5195 Molex 5194 7 -V COM COM COM or equivalent or equivalent 8 +V V2 V2 V2 9 +V V2 V2 V2 10 P.F.D. P.F.D. P.F.D. P.F.D. 11 NC NC V3 V3 12 No Pin No Pin No Pin No Pin 13 NC NC NC V4 Derating Curve Static Characteristics 100 100 25CFM forced air cooling 90 80 80 MPS/D-120 Convection cooling 70 60 53W MPS-120-3.3 only 73.7W MPS-120-5 only 60 MPT/Q-120 40 80W others 50 20 40 -20 0 10 20 30 40 50 55 60 70 (HORIZONTAL) 90 100 115 135 155 230 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:120W MEDICAL-SPEC 2011-03-31 LOAD (%) LOAD(%) 10cm 35.5 [1.4"] 95.25[3.75"] 107.95[4.25"]
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the MPQ-120C?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers







What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods