200 W, QUAD OUTPUT, 5 V@15 A | 12 V@7 A | -5 V@2 A | -12 V@2 A MEDICAL OPEN FRAME AC-DC POWER SUPPLY

Part Number

MPQ-200B

Price

Request Quote

Manufacturer

MEAN WELL

Lead Time

Request Quote

Category

Circuit Protection »  AC-DC Power Supply

Specifications

Manufacturer

MEAN WELL

Manufacturers Part #

MPQ-200B

Industry Aliases

MPQ-200B

Series

MPS-200

Factory Pack Quantity

1

Application

General Purpose

Connection Type

Molex/JST

Convection Rating

140 W

Cooling Method

Air-Cooled, Convection

Dimensions

7.00 x 4.22 x 1.40"

Efficiency

78%

Environmental Conditions

General Purpose

Industry

Medical

Input Type

AC

Mechanical Style

Open / Enclosed Frame

Number of Outputs

4

Operating Temperature

-20 to +70°C, derate linearly to 50% power from 50-70°C

Output Amps 1

15 A

Output Amps 2

7 A

Output Amps 3

2 A

Output Amps 4

2 A

Output Voltage V1 Nominal

5 V

Output Voltage V2 Nominal

12 V

Output Voltage V3 Nominal

-5 V

Output Voltage V4 Nominal

-12 V

Package Type

Open Frame

Power

200 W

Protection Level

2xMOPP

Subcategory

AC-DC Power Supply

Datasheet

pdf file

Meanwell-MPS-200-Series-200W-Medical-Power-Supply-datasheet1-823945142.pdf

335 KiB

Extracted Text

1~4 Output Medical Type 200W M edical seri es Features Universal AC input / Full range Low leakage current <180 A Protections: Short circuit / Overload / Over voltage / Over temperature Free air convection for 140W and forced air convection for 200W ANSI/AAMI ES60601-1 medical safety approved With power good and fail signal output Built-in remote ON-OFF control Built-in remote sense function Fixed switching frequency at 100KHz 3 years warranty Specification AC INPUT VOLTAGE WORKING TEMP. 90~264 VAC, 47~440Hz / 127~370VDC. Whole series can operate from -20~70 . Please refer to the derating curves. POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load WORKING HUMIDITY 20~90% RH non-condensing. AC INPUT CURRENT (Typ.) Maximum input current 3.5A at 115VAC, 60Hz or STORAGE TEMP., HUMIDITY 1.6A at 230VAC, 60Hz with 100% output load. -40~+85 , 10~90% RH INRUSH CURRENT (Typ.) TEMP. COEFFICIENT Inrush current is less than 25A at 115VAC or 0.04%/ on all outputs at full load between 0~50 of ambient temperature. less than 40A at 230VAC under cold start conditions. Limiting provided by internal VIBRATION thermistors. 2G of acceleration, vibrating frequency adjust from 10Hz ~500Hz within a 10-minute cycle. 6 testing cycles (60 minutes) each along X, Y, Z axes. SETUP, RISE TIME 1000ms, 20ms / 230VAC at full load SAFETY STANDARDS 3000ms, 20ms / 115VAC at full load Medical : ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved Commercial : Also design refer to UL60950-1, TUV EN60950-1 HOLD-UP TIME (Typ.) 16ms / 230VAC at full load WITHSTAND VOLTAGE 16ms / 115VAC at full load 4000VAC between input and output 1500VAC between input and F.G. LEAKAGE CURRENT 1500VAC between output and F.G. Leakage current is less than 180 A at 264VAC for earth leakage current ISOLATION RESISTANCE Leakage current is less than 100 A at 264VAC for >100M Ohms for I/P-O/P, I/P-FG, O/P-FG by using 500VDC test voltage. patient leakage current EMI COMPLIANCE DC OUTPUT ADJ. RANGE EMI Specifications Compliance Level DC output voltage (or CH1 of multiple output models) Conducted & Radiation EN55011, Class B can be adjusted between -5%~+10% rated output EN55022, Class B voltage by potential meter. Harmonic distortion EN61000-3-2 Voltage flicker EN61000-3-3 OVERLOAD PROTECTION Fully protected against short circuit and output overload. EMS COMPLIANCE The hiccup type protection will be activated at 120~160% EMS Specification Compliance Level rated load and recovers automatically after fault condition ESD air EN61000-4-2, Level 3, 8KV is removed. ESD contact EN61000-4-2, Level 2, 4KV RF field susceptibility EN61000-4-3, Level 2, 3V/m OVER VOLTAGE PROTECTION Level 3, 10V/m Provided on output channel 1 only at 115%~135% EFT(Electrical Fast Transient)/Burst EN61000-4-4, Level 2, 1KV/5KHz rated output voltage. Level 3, 2KV/5KHz Output will be shut down when this protection is activated. Lightning/Surge EN61000-4-5, Level 4, 2KV/Line-Line 4KV/Line-Earth OVER TEMPERATURE PROTECTION Conducted RF susceptibility EN61000-4-6, Level 2, 3Vrms/m When the temperature of TSW1 which detect on heat sink of Level 3, 10Vrms/m power transistor reaches 95 This protection is activated. Magnetic field immunity EN61000-4-8, Level 2, 3A/m Then output will be shut down and recovers automatically Level 3, 10A/m after temperature goes down. Voltage dip, interruption EN61000-4-11,Compliance Digital phone carrier immunity ENV50204, Level 2, 3V/m, 900MHz POWER GOOD / FAIL SIGNAL Level 3, 10A/m, 900MHz TTL logic high for power good and TTL low for MTBF power fail. When the output voltage reaches 90% of 262,100 hours min. at full load and 25 of ambient temperature, rated value, a +5V TTL signal will be sent out with a calculated per MIL-HDBK-217F. 10~500ms delay; At least 1ms before the output voltage goes below 90% of the rated value, the TTL DIMENSION (L*W*H) signal will be turned off. 177.8x107.2x35.5mm or 7"x4.22"x1.4" * MPS-200-3.3 does not have this function. PACKING REMOTE CONTROL 0.66Kg; 24pcs/16.8Kg/0.99CUFT RC+/RC-:0 ~ 0.8V=power on; 4 ~ 10V=power off sink current<4~10mA File Name:200W MEDICAL-SPEC 2012-02-20 1~4 Output Medical Type 200W M edi cal series Output Chart OUTPUT CURRENT RIPPLE & NOISE VOLTAGE OUTPUT RATED LINE LOAD EFFICIENCY PEAK LOAD (Max.) MODEL TOLERANCE MINIMUM WITH FAN VOLTAGE CURRENT CONVECTION REGULATION REGULATION (typ.) WITH 25CFM FAN (Note 2) (Note 3) LOAD (25CFM) (max.) (Note 4) MPS-200-3.3 3.3V 40A 0A 28A 40A 48A 80mVp-p 2.0% 0.5% 1.0% 77% MPS-200-5 5V 40A 0A 28A 40A 48A 80mVp-p 2.0% 0.5% 1.0% 81% MPS-200-12 12V 16.7A 0A 11.7A 16.7A 20A 100mVp-p 2.0% 0.5% 1.0% 84% MPS-200-15 15V 13.4A 0A 9.4A 13.4A 16A 100mVp-p 2.0% 0.5% 1.0% 85% MPS-200-24 24V 8.4A 0A 5.9A 8.4A 10A 150mVp-p 1.0% 0.5% 1.0% 86% MPS-200-48 48V 4.2A 0A 3A 4.2A 5A 200mVp-p 1.0% 0.5% 1.0% 87% MPD-200A 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 82% 12V 8A 0.8A 5.4A 8A 9.6A 120mVp-p +8,-5% 1.0% 4.0% MPD-200B 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 83% 24V 4A 0.4A 2.7A 4A 4.8A 180mVp-p 6.5% 1.0% +4,-6% MPT-200A 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 12V 7.5A 0.8A 5A 7.5A 9A 120mVp-p 8.0% 1.0% 5.0% 80% -5V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPT-200B 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 12V 6A 0.6A 4.4A 6A 7.2A 120mVp-p 8.0% 1.0% 5.0% 80% -12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPT-200C 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 15V 4.7A 0.5A 3.3A 4.7A 5.6A 150mVp-p 8.0% 1.0% 5.0% 80% -15V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPT-200D 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 24V 3A 0.3A 2.2A 3A 3.6A 180mVp-p 8.0% 1.0% 5.0% 81% 12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPQ-200B 5V 15A 3A 12A 15A 18A 80mVp-p 2.0% 0.5% 1.0% 12V 7A 0.7A 5.3A 7A 8.4A 120mVp-p 8.0% 1.0% 5.0% 78% -5V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% -12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPQ-200C 5V 15A 3A 12A 15A 18A 80mVp-p 2.0% 0.5% 1.0% 15V 5A 0.5A 4A 5A 6A 150mVp-p 6.0% 1.0% 5.0% 78% -5V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% -15V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPQ-200D 5V 15A 3A 12A 15A 18A 80mVp-p 2.0% 0.5% 1.0% 24V 3A 0.3A 2.3A 3A 3.6A 180mVp-p 8.0% 1.0% 5.0% 79% 12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% -12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPQ-200F 5V 15A 3A 12A 15A 18A 80mVp-p 2.0% 0.5% 1.0% 24V 2.7A 0.3A 2.1A 2.7A 3.3A 180mVp-p 8.0% 1.0% 5.0% 81% 15V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% -15V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% Notes : 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) 6. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:200W MEDICAL-SPEC 2012-02-20 15cm 1~4 Output Medical Type 200W M edi cal series Mechanical Specification(MPS-200) Unit:mm 177.8[7"] 165.1[6.5"] 6.35[0.25"] SVR1 1 4 CN4 LED 2 5 3 6 10 20 9 19 8 18 7 17 6 16 5 15 4 14 3 13 2 12 CN1 1 11 3 CN2 2 1 FG 4- 3.96[0.156"] 25CFM min. FAN 3[0.118"] max. AC Input Connector (CN1) : JST B3P-VH or equivalent DC Output Connector (CN4) : JS-2008-03*2 or equivalent Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal 1 AC/N 1 PG JST VHR JST SVH-21T-P1.1 2 No Pin 2 RS- or equivalent or equivalent 3 AC/L 3 GND JS-2007-03*2 JS-2007-T or equivalent or equivalent 4 RC+ DC Output Connector (CN2) : MOLEX 5566-20 or equivalent 5 RS+ Pin No. Assignment Mating Housing Terminal 6 RC- 1~5,11~15 DC OUTPUT -V MOLEX 5557 MOLEX 5556 6~10,16~20 DC OUTPUT +V or equivalent or equivalent Derating Curve (MPS-200) Static Characteristics (MPS-200) 100 100 25CFM forced air cooling 90 80 80 Convection cooling 70 60 60 40 50 20 40 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 100 115 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:200W MEDICAL-SPEC 2012-02-20 LOAD (%) 107.2[4.22"] 35.5[1.4"] 95.25[3.75"] 6.1[0.24"] LOAD(%) 15cm 1~4 Output Medical Type 200W M edi cal series Mechanical Specification(MPD/T/Q-200) 177.8[7"] 165.1[6.5"] 6.35[0.25"] SVR1 1 4 LED 2 5 CN4 3 6 1 CN2 CN1 3 CN3 2 1 16 FG 4- 3.96[0.156"] 25CFM min. FAN 3[0.118"] max. AC Input Connector (CN1) : JST B3P-VH or equivalent DC Output Connector (CN4) : JS-2008-03*2 or equivalent Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal 1 AC/N 1 PG JST VHR JST SVH-21T-P1.1 2 No Pin 2 RS- or equivalent or equivalent 3 AC/L 3 GND JS-2007-03*2 JS-2007-T or equivalent or equivalent 4 RC+ DC Output Connector (CN2,3) : JST B8P-VH*2 or equivalent 5 RS+ Pin No. Assignment Mating Housing Terminal 6 RC- 1,2,3,4 V1 5~11 COM 12,13 V2 JST VHR JST SVH-21T-P1.1 or equivalent or equivalent 14 V3 15 No pin 16 V4 Derating Curve (MPD/T/Q-200) Static Characteristics (MPD,T,Q-200) 100 100 25CFM forced air cooling 90 MPT/Q-200 MPD-200 80 80 Convection cooling 70 60 MPT/Q-200 60 MPD-200 40 50 20 40 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 100 115 140 160 180 200 220 240 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:200W MEDICAL-SPEC 2012-02-20 LOAD (%) 107.2[4.22"] 35.5[1.4"] 95.25[3.75"] 6.1[0.24"] LOAD(%)

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the MPQ-200B?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

CONN POWER PL 2 POS WALL MOUNT 2 TERMINAL 1 PORT ACPLUG-AU

product

CONN POWER PL 2 POS WALL MOUNT 2 TERMINAL 1 PORT ACPLUG-EU

product

CONN POWER PL 2/3/2/2 POS WALL MOUNT 9 TERMINAL 4 PORT ACPLUG-MIX

product

CONN POWER PL 3 POS WALL MOUNT 3 TERMINAL 1 PORT ACPLUG-UK

product

CONN POWER PL 2 POS WALL MOUNT 2 TERMINAL 1 PORT ACPLUG-US

product

WALL MOUNT AC ADAPTERS AUSTRALIAN AC PLUG FOR GEM18I SERIES