Part Number | SPD-20-277P |
---|---|
Manufacturer | MEAN WELL |
Category | Power » Power Accessories |
Price | Request Quote |
Lead Time | Request Quote |
SPD-20-277P
Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.
Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.
Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.
Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.
Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.
Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.
After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.
Electronics Finder is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.
Do you need a SPD-20-277P? We can help you find it at a competitive price!
Manufacturer | MEAN WELL |
---|---|
Manufacturers Part # | SPD-20-277P |
Factory Pack Quantity | 1 |
Download "SPD-20-SPEC.pdf" (495 KiB)
20kA Surge Protection Device SPD-20 series ■ Features : ‧Type 2 component assemblies ‧Line to Ground&Line to Line protected ‧Parallel(3 wires) connection style ‧LED status indicator ‧Suitable for LED driver surge protection ‧IP67 design for indoor or outdoor installations IP67 (Only SPD-20-240P) (Only SPD-20-240P) E353892 SPECIFICATION MODEL SPD-20-240P SPD-20-277P OPERATING VOLTAGE 240VAC 50/60Hz 277VAC 50/60Hz MCOV(MAX. CONTINUOUS OPERATING VOLTAGE) 300VAC 320VAC UC(MAX. CONTINUOUS OPERATING VOLTAGE)Note.4 300VAC ------ VPR (VOLTAGE PROTECTION RATING) 1500V(L-FG,N-FG,L-N) UP (VOLTAGE PROTECTION LEVEL)Note.5 1500V(L-PE,N-PE,L-N) ------ IN (NOMINAL DISCHARGE CURRENT) 5kA MAX. SURGE CURRENT(8/20us) 20kA Imax. (MAX. DISCHARGE CURRENT) Note.6 20kA ------ SCCR (SHORT CIRCUIT CURRENT RATING)Note.3 5kA ------ SHORT-CIRCUIT WITHSTAND Note.7 1.5kA RESPONSE TIME <25ns WITHSTAND Note.1 1600VAC 1minutes -40 ~ +70℃ OPERATING TEMPERATURE SAFETY STANDARDS UL1449(Third Edition),CS22.2 NO.8,EN61643-11(only SPD-20-240P) approved DIMENSION 90*70*50mm (L*W*H) PACKING 0.39Kg; 18pcs/8Kg/0.84CUFT NOTE 1. Varistors are to be removed during this test 2. Note.4,Note.5,Note.6,Note.7 are for EN61643-11(SPD-20-240P) 3. These devices have been subjected to Surge Testing and Current Test-short Circuit Current Rating by employing a class J Fuse Rated 30A and minimum 600VAC. Mechanical Specification CONNECTIONS Case No. SPD-20A Unit:mm L 90 5.1 N 2 150±5 FG LED AC/N AC/L 10AWG FEP ψ4.2 AC/L(BLACK) SPD 150±5 150±5 FG/PE 10AWG FEP 10AWG FEP FG(GREEN) PE(GREEN) ψ4.2 AC/N(WHITE) LED 2 5.1 3.19 3.19 File Name:SPD-20-SPEC 2014-03-14 18 3 5.1 70 5.1 28 50 20kA Surge Protection Device SPD-20 series Circuit Diagram AC/N D2 LED2 R2 AC/L D1 LED1 R1 FG/PE INSTALLATION 1. This document provides detailed information on how to install and operate the SPD-20 of Surge Protective Devices(SPDS). 2. The SPD-20 of Surge Protective Devices are installed/connected in parallel with the line of TN System 3. Incorrect installation may significantly impair the performance of the SPD. It is particularly important that all installation procedures and guidelines be followed exactly. 4. Before starting any installation procedures, verify service voltage(AC or DC)with a volt meter to ensure that the correct model has been selected for the supply voltage. 5. DO NOT INSTALL THE SPD IF MEASURED VOLTAGE EXCEEDS UNIT RATINGS. 6. REMOVE POWER FROM ELECTRICAL SYSTEM PRIOR TO INSTALLATION. 7. ENSURE THAT ALL CONNECTIONS ARE CORRECT BEFORE ENERGIZING. 8. Apply power(energize),LED indicator should illuminate. If LED is out, the SPD requires service. 9. Never install on an ungrounded system. ! DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Thoroughly read and comprehend all instructions before commencing installation. This equipment must be installed by qualified electrical personnel in accordance with all applicable codes which supersede these instructions. Improper installation or misapplication of these devices may result in death or serious injury. Failure to follow these instructions could result in damage to the electrical system(s) or related equipment. ! CAUTION HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Never install this unit if it has fallen, has been dropped or looks damaged in any way. Return device to factory for diagnostic testing. File Name:SPD-20-SPEC 2014-03-14 ZNR2 ZNR1 ZNR3
Any product names, logos, brands, and other trademarks or media featured or referred to on Electronics Finder are the property of their respective owners.
GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.
All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.