MEAN WELL UHP-200-5
Specifications
Manufacturer
MEAN WELL
Manufacturers Part #
UHP-200-5
Industry Aliases
UHP-200-5
Series
UHP-200
Factory Pack Quantity
1
Application
LED Power Supply
Compliance
General Safety
Convection Rating
200 W
Dimensions
6.57 x 1.02 x 2.17"
Efficiency
89%
Environmental Conditions
General Purpose
Industry
LED Lighting
Mechanical Style
Open / Enclosed Frame
Number of Outputs
1
Operating Temperature
-30 to +70°C, derate linearly from 50-70°C to 60% power
Output Amps 1
40 A
Output Voltage V1 Nominal
5 V
Power
200 W
Subcategory
AC-DC Power Supply
Weight
.42 KG
Datasheet
Extracted Text
200W Slim Type with PFC Switching Power Supply UHP-200 series Bauart gepruft Sicherheit egelma ge od os be wac g S&E www.tuv.com ID 2000000000 GB4943 EN60950-1 UL60950-1 IEC60950-1 EN60335-1 ■ �������� ■ ������������ ‧������� ���������������� ‧Industrial automation machinery ‧������� ����������� ���������� ‧Industrial control system ‧��� ����� !��"#$ �%������%����&������� ‧Mechanical and electrical equipment ‧�%���’�� ������ (�$�%������ ‧Electronic instruments, equipments ‧)&�% ���� ���� ����*����+�)����� or apparatus ‧Household appliances ‧-~ !�+,�℃���������������%�� ‧LED display application ‧(����������- � �������%��./������� . /��� ������� ./�����������%�� ‧0$ /1 ������ ������������%����� �%�������������� ‧/�������� �����%��%���&�������� �2���3&� ‧�40 ��������� ���������� ‧! +���� �������+ ■ ����������� UHP-200 series is a 200W single-output slim type power supply with 26mm of low profile design. Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 3.3V, 4.2V, 5V, 12V, 15V, 24V, 36V and 48V. In addition to the high efficiency up to 94%, that the whole series operates from -30℃℃ ~ 70 under air convection without fan. UHP-200 has the complete protection functions and 5G anti-vibration capability;It is complied with the international safety regulations such as TUV EN60950-1, EN60335-1, UL60950-1 and GB4943. UHP-200 series serves as a high performance power supply solution for various industrial applications. ■ ������������� ���� ��� � � /%��%�"������ ����� � ������������ ���������� 5+�� 0���������� 2��� ����� 4������� 6������ R �%���’��0$/1������������������%������%������3 6������ File Name:UHP-200-SPEC 2018-01-16 200W Slim Type with PFC Switching Power Supply UHP-200 series SPECIFICATION MODEL UHP-200 -3.3 UHP-200 -4.2 UHP-200 -5 UHP-200 -12 UHP-200 -24 UHP-200 -36 UHP-200 -48 UHP-200 -15 DC VOLTAGE 3.3V 4.2V 5V 12V 15V 24V 36V 48V RATED CURRENT 40A 40A 40A 16.7A 13.4A 8.4A 5.6A 4.2A RATED POWER(convection) 132W 168W 200W 200.4W 201W 201.6W 201.6W 201.6W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 200mVp-p 240mVp-p 240mVp-p 240mVp-p 240mVp-p 300mVp-p VOLTAGE ADJ. RANGE 3.6~4.4V 3.2~3.5V 4.5~5.5V 11.4~12.6V 14.3~15.8V 22.8~25.2V 34.2~37.8V 45.6~50.4V OUTPUT VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.3% ±0.3% ±0.3% LOAD REGULATION ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% SETUP, RISE TIME 2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load HOLD UP TIME (Typ.) 10ms/230VAC 10ms/115VAC VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF≥≥ 0.94/230VAC PF 0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 89% 90% 91% 93% 94% 94% 94% 94% AC CURRENT (Typ.) 2.2A/115VAC 1.1A/230VAC INRUSH CURRENT (Typ.) Cold start 40A/115VAC 80A/230VAC LEAKAGE CURRENT <0.75mA / 240VAC 110~140% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 3.8~ 4.6V 4.62 ~ 5.46V 5.75 ~ 6.75V 13.2 ~ 15.6V 16.5 ~ 19.5V 26.4 ~ 31.2V 39.6 ~46.8V 52.8 ~ 62.4V OVER VOLTAGE Protection type :Shut down O/P voltage,re-power on to recover OVER TEMPERATURE Protection type :Shut down O/P voltage, recovers automatically after temperature goes down DC OK SIGNAL(Optional) Contact rating(max.):15Vdc/10mA resistive load FUNCTION For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically REDUNDANT(Optional) enabled. This can prevent the system crash, and provide the reliability of system WORKING TEMP. -30 ~ +70℃(Refer to “Derating Curve") 20 ~ 90% RH non-condensing WORKING HUMIDITY -40 ~ +85℃, 10 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY ±℃ 0.03%/ (0 ~ 50℃) TEMP. COEFFICIENT 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes VIBRATION SAFETY STANDARDS UL60950-1,TUV EN60950-1,EN60335-1, CCC GB4943, EAC TP TC 004 approved,Design refer to EN61558-1,-2-16 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH EMC EMC EMISSION Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3,EAC TP TC 020 (Note.6) EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020 MTBF 257K hrs min. MIL-HDBK-217F (25℃) OTHERS 194*55*26mm (L*W*H) DIMENSION 0.468kg;24pcs/12.2kg/0.49CUFT PACKING )3 #�� ���������� 2/5 ��������+ ��������� ��� ����%��� �� �!�"#$ ���%�� ����� ���� ��� �& �� ��*���� ��������%��3 �3������7������������%�������89:��*������� *+%�����)�;�����������’����������������� ��3)%�7<,%������������������3 NOTE !3 5�������� -����%��� ��� %� ���������� ���� ���%������ ��� ���� ���%������3 <3 0������� ��+ *� ������ %���� ��� ���%� ��������3 (����� � ��� � � �������� �%��� ��� ���� �������3 &3 The ��*���� ��������%�� �������� �� & .)���� �� ������ ��� ��������� �����%�� ������� � �� �������&����� �3 The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. ��� �%������ �� �� �� ������� � ��� 48$ ������ ������ ����� �� =486 ������� �� ��������� ����� �%������3> ��� ������*�� �� ���-..���3 ��������3���� File Name:UHP-200-SPEC 2018-01-16 200W Slim Type with PFC Switching Power Supply UHP-200 series Block Diagram POWER EMI FILTER RECTIFIERS +V PFC & I/P SWITCH- & CIRCUIT -V RECTIFIER ING FILTER FG DETECTION CIRCUIT O.T.P. O.L.P. CONTROL O.V.P. DC OK Function Redundant Function Derating Curve 230Vac for other 100 100 230Vac for 4.2V,5V;100Vac for other 80 80 100Vac for 4.2V,5V 60 60 40 40 20 20 -30 010203040506070 (HORIZONTAL) -20 010203040506070 (HORIZONTAL) AMBIENT TEMPERATURE (℃) AMBIENT TEMPERATURE WITHOUT ALUMINUM PLATE(℃) 100 80 60 40 20 -30 010203040506070 80 90 (HORIZONTAL) Tcase (℃) File Name:UHP-200-SPEC 2018-01-16 RATED CURRENT (%) RATED CURRENT (%) RATED CURRENT (%) 200W Slim Type with PFC Switching Power Supply UHP-200 series STATIC CHARACTERISTIC 100 90 80 70 60 50 40 90 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (V) 60Hz Function Manual 1.DC_OK Signal DC_OK is a collector shorted signal. It is used by an optocoupler in the power supply which indicates the output status of the power supply as exhibited below. DC OK +V +V PSU turns on DC ok Optocoupler C-E Pin Conduction PSU turns off Optocoupler C-E Pin Open DC fail Optocoupler Rating(max.) 15Vdc/10mA resistive load GND COM PSU 2.Redundant function (1) UHP-200R is built-in redundant function and can be connected 2 units in parallel . (2) When in parallel operation the maximum load should not be greater than the rated power of any PSU. +V +V PSU LOAD -V -V +V PSU -V File Name:UHP-200-SPEC 2018-01-16 LOAD (%) E C 1K 200W Slim Type with PFC Switching Power Supply UHP-200 series Mechanical Specification CASE NO.:249B Unit:mm 194 188 3 12 1 3 2 2 3 1 4 VR 3 49.25 97 tc tc ‧ : Max. Case Temperature AC Input Terminal(TB1) pin NO. Assignment DC Output Terminal(TB2,TB3) pin NO. Assignment Pin No. Assignment Terminal Max mounting torque Pin No. Assignment Terminal Max mounting torque 1 AC/L 1,2 -V (MW) (DEGSON) 2 AC/N 5Kgf-cm 8Kgf-cm TB-HTP-200-40A DG28C-B-03P 3,4 +V 3 DC OK Connector(CN10):JST B2B-PH-K-S or requivalent Pin No. Assignment Mating Housing Terminal 1 DC COM JST PHR-2 JST SPH-002T-P0.5S or requivalent or requivalent 2 DC OK +V File Name:UHP-200-SPEC 2018-01-16 R1.65 7.62 17.25 13 7.75 8 8.5 8.8 42 26 6.5 55 300 200W Slim Type with PFC Switching Power Supply UHP-200 series Installation 1.Operate with additional aluminum plate In order to meet the“Derating Curve”and the “Static Characteristics” ,UHP-200 series must be installed onto an aluminum plate(or the cabinet of the same size) on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and smooth surface (or coated with thermal grease), and UHP-200 series must be firmly mounted at the center of the aluminum plate. unit:mm M3*4 File Name:UHP-200-SPEC 2018-01-16 300 3
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the UHP-200-5?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers







What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods