Electronics Finder Manufacturers M MURATA POWER SOLUTIONS UEI15-120-Q48P-C
About product Specifications Datasheet FAQ

MURATA POWER SOLUTIONS UEI15-120-Q48P-C

Image of MURATA POWER SOLUTIONS UEI15-120-Q48P-C

Description

15.6 W, 18 -75 VDC VIN, SINGLE OUTPUT, 12 VDC@1.3 A DC-DC CONVERTER
UEI15-120-Q48P-C

Part Number

UEI15-120-Q48P-C

Price

Request Quote

Manufacturer

MURATA POWER SOLUTIONS

Lead Time

Request Quote

Category

Capacitors »  DC-DC Converter

Specifications

Manufacturer

Murata Power Solutions

Manufacturers Part #

UEI15-120-Q48P-C

Lead Time

30 Week Lead Time

Selling Alternatives

NPH10S4812EIC, NPH10S4812IC

Series

UEI15

Factory Pack Quantity

30

Cooling Method

Convection

Dimensions

1.10 x 0.96 x 0.32"

Efficiency

85%

Input Voltage Nominal

48 VDC

Isolation

2250 VDC

Mechanical Style

Isolated

Mounting

Through Hole

Number of Outputs

1

Operating Temperature

- 40 to + 85°C

Output Amps 1

1.3 A

Output Voltage V1 Nominal

12 VDC

Power

15.6 W

Subcategory

DC-DC Converter

Datasheet

pdf file

mdc_uei-15w.pdf

3061 KiB

Extracted Text

UEI15 Series www.murata-ps.com Isolated Wide Input Range 15-Watt DC-DC Converters Typical unit Featuring a full 15 Watt or greater output in one square inch of board area, the UEI series isolated DC/DC converter family offers effi cient regulated DC power for printed circuit board mounting. FEATURES PRODUCT OVERVIEW  Small footprint DC/DC converter, ideal for Wide range 4:1 inputs on the 0.96" x 1.1" x 0.33" and noise specifi cations assure compatibility to converter are either 9 to 36 Volts DC (Q12 models) circuits using CPU’s, ASIC’s, programmable logic high current applications or 18 to 75 Volts DC (Q48 models), ideal for battery- and FPGA’s. For systems requiring controlled  Industry standard 0.96" x 1.1" X 0.33" open powered and telecom equipment. The industry- startup/shutdown, an external switch, transis- frame package and pinout standard pinout fi ts larger 1" x 2" converters. Fixed tor or digital logic may be used to activate the  Wide range input voltages 9-36 and 18-75 Vdc output voltages from 3.3 VDC to 15 VDC are regu- remote On/Off control. lated to within ±0.2% or less and may be trimmed A wealth of self-protection features avoid both  Assembly and attachment for RoHS standards within ±10% of nominal output. Applications converter and external circuit problems. These  Isolation up to 2250 VDC (basic) include small instruments, area-limited microcon- include input undervoltage lockout and overtem-  Up to 15 Watts or greater total output power trollers, computer-based systems, data communi- perature shutdown. The outputs current limit using with overtemperature shutdown cations equipment, remote sensor systems, vehicle the “hiccup” autorestart technique and the outputs and portable electronics. may be short-circuited indefi nitely. Additional  High effi ciency synchronous rectifi er forward The UEI 15W series includes full magnetic and features include output overvoltage and reverse topology optical isolation up to 2250 Volts DC (basic insula- conduction elimination.  Stable operation with no required external tion). For connection to digital systems, the outputs The high effi ciency offers minimal heat buildup components offer fast settling to current step loads and toler- and “no fan” operation. ance of higher capacitive loads. Excellent ripple  Usable -40 to 85°C temperature range (with derating)  Certifi ed to UL 60950-1, CAN/CSA-C22.2 No. 60950-1, IEC60950-1, EN60950-1 safety ap- provals, 2nd edition  Extensive self-protection shut down features +VOUT +VIN –VOUT On/Off Control Control GATE DRIVE ISOLATION BARRIER −VIN Reference, Trim & ISOLATION TRIM Error Amplifier Figure 1. Simplifi ed block diagram—3.3V and 5Vout models only. Typical topology is shown. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_UEI15W.C17 Page 1 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀ Output Input Open Frame R/N (mVp-p) ➁ Regulation (Max.) Iin = Iin = Efficiency Package – C75 Vin no full Vout Iout Power Nom. Range load load Case Root Models ➀ (V) (A) (W) Typ. Max. Line Load (V) (V) (mA) (A) Min. Typ. (inches) (mm) Pinout UEI15-033-Q12 3.3 4.5 14.85 60 90 ±0.05% ±0.1% 24 9-36 43 0.71 86.5% 89% UEI15-033-Q48 3.3 5 16.5 60 90 ±0.2% ±0.2% 48 18-75 24 0.4 85.5% 88% UEI15-050-Q12 5 3 15 70 125 ±0.05% ±0.075% 24 9-36 41 0.72 86.3% 87.3% UEI15-050-Q48 5 3 15 60 95 ±0.05% ±0.06% 48 18-75 28 0.36 84.3% 86.0% 1.1×0.96×0.33 27.9×24.4×8.4 P85 UEI15-120-Q12 12 1.3 15.6 110 150 ±0.05% ±0.05% 24 9-36 15 0.77 82.3% 84.5% UEI15-120-Q48 12 1.3 15.6 85 120 ±0.0 75% ±0.05% 48 18-75 15 0.38 83.3% 85% UEI15-150-Q12 15 1.1 16.5 130 175 ±0.05% ±0.05% 24 9-36 18 0.81 83.5% 85% UEI15-150-Q48 15 1.1 16.5 80 120 ±0.05% ±0.05% 48 18-75 14 0.4 83.3% 85.3% ➀ Please refer to the part number structure for additional options and complete ➂ Minimum output load for all models is 10% of maximum current. ordering part numbers. ➃ RoHS-6 compliance does not claim EU RoHS exemption 7b (lead in solder). ➁ All specifications are typical at nominal line voltage and full load, +25 deg.C. unless otherwise noted. See detailed specifications. PART NUMBER STRUCTURE UEI15 - 033 - Q12 P M H Lx - C RoHS-6 Hazardous Substance Compliance (note 4) Unipolar Wide Input 15-Watt Series Pin Length Option Blank = Std. pin length 0.25˝ (6.3mm) Nominal Output Voltage Conformal Coating Option L1 = 0.110˝ (2.79mm) ➀ in Tenths of a Volt Blank = No coating, standard L2 = 0.145˝ (3.68mm) ➀ H = Coating added, optional (Built to order; contact Murata Power Solutions for MOQ and lead times. Not available on SMT models.) Input Voltage Range Surface Mount Option Q12 = 9-36V Blank = Standard through-hole pin mount version Q48 = 18-75V M = SMT version (MSL rating 2) ➁ On/Off Control Logic: P = Positive N = Negative ➀ Special quantity order is required; samples available with standard pin length only. ➁ SMT (M) versions not available in sample quantities. ➂ Some model number combinations may not be available. See website or contact your local Murata sales representative. SPECIAL CUSTOMER CONFIGURATION PART NUMBERS: 1) UEI-31204-C (Restricted AVL and surface mount package) 2) UEI15-050-Q12PH-31331 (5Vout @ 15W, Positive Logic, Conformal Coating, Hi-pot Tested to 2,000Vrms) www.murata-ps.com/support MDC_UEI15W.C17 Page 2 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters FUNCTIONAL SPECIFICATIONS INPUT CHARACTERISTICS Under- Reflected Recom- Input Current Remote On/Off Control Start-up voltage (back) mended Internal Reverse Negative Logic threshold Shut- Ripple Inrush Min. Output Short Standby Fast-blow Input Polarity On/Off Positive Logic "N" model down Current Transient Load Circuit Low Line Mode Fuse Filter Protec- Current blank model 2 Model Family V V mA pk-pk A sec mA mA A mA A Type tion mA suffix suffix 18 UEI15-033-Q12 9.1 8.6 100 1.86 4 UEI15-033-Q48 16.7 15.6 65 1.03 2 C OFF=open pin 18 None. OFF=Gnd pin UEI15-050-Q12 9.5 8.5 105 1.90 4 or +10 to + Install or –0.7 to +0.7V UEI15-050-Q48 16.7 15.6 60 0.96 2 L 15V max. 30 0.05 50 1 external 1 max. ON=open 18 ON=Gnd pin UEI15-120-Q12 9.5 8.4 110 2.04 4 fuse. See pin or +10 to or –0.7 to 16.7 15.6 56 1.02 1.5 UEI15-120-Q48 note 15. +15V max. C +0.8V max. 18 UEI15-150-Q12 9.5 8.4 130 2.13 4 UEI15-150-Q48 16.7 16.2 60 1.06 2 OUTPUT CHARACTERISTICS Vout 19 Iout Accuracy Adjustment Temperature Capacitive Loading Max. Overvoltage protection Max. 50% Load Range Coefficient Low ESR <0.02Ω Max, Model Family mA % of Vnom % of Vnom % of Vout /ºC µF V UEI15-033-Q12 4.5 UEI15-033-Q48 See 1,000 3.9 UEI15-050-Q12 Ordering 5.9 17 UEI15-050-Q48 Guide 470 5.9 Magnetic ±1 ±10 ±0.02 See ordering guide feedback UEI15-120-Q12 1,000 14.1 (Minimum UEI15-120-Q48 load is 10% 15 UEI15-150-Q12 470 19.5 of Imax) UEI15-150-Q48 20 ISOLATION CHARACTERISTICS DYNAMIC CHARACTERISTICS Dynamic Load Isolation Start-up Time Peak Response Input to Resistance Isolation Isolation Switching (50-75-50% Deviation Vin to Vout regulated Remote On/Off to Vout Output Min. Min. Capacitance Safety Frequency load step) µSec mV (Max.) mSec regulated max.) mSec Model Family Vdc MΩ pF Rating Model Family KHz to 1% Vout ➀ UEI15-033-Q12 2000 10 1000 UEI15-033-Q12 150 ±125 350 UEI15-033-Q48 2250 10 1500 UEI15-033-Q48 ±35 350 UEI15-050-Q12 2000 10 1500 UEI15-050-Q12 100 ±60 350 UEI15-050-Q48 2250 10 1000 UEI15-050-Q48 ±30 375 Basic 50 50 insulation UEI15-120-Q12 2000 10 1000 UEI15-120-Q12 150 ±150 340 UEI15-120-Q48 2250 10 1000 UEI15-120-Q48 ±200 350 UEI15-150-Q12 2000 10 1500 UEI15-150-Q12 100 ±125 340 UEI15-150-Q48 2250 10 1000 UEI15-150-Q48 ±175 380 MISCELLANEOUS CHARACTERISTICS Operating Temperature Range Short Circuit Current Limit Short Short Storage Thermal Duration Calculated Inception 98% of Circuit Circuit Pre- See Temperature protection/ (output shorted MTBF Vout, after warmup Protection Current biased Derating Range shutdown Model Family A Method A to ground)➀ setup Hours ➃ Curves ºC ºC 6 UEI15-033-Q12 6.0 2 x 10 6 UEI15-033-Q48 7.2 3.49 x 10 UEI15-050-Q12 4.6 115 Current 6 UEI15-050-Q48 4.5 2 x 10 limiting, 0.3 Continuous Monotonic –40 to +85ºC –55 to +125 ºC hiccup UEI15-120-Q12 2.0 autorestart 6 UEI15-120-Q48 1.8 4.1 x 10 135 6 UEI15-150-Q12 1.6 2.1 x 10 115 6 UEI15-150-Q48 1.7 2 x 10 Remove overload for recovery. www.murata-ps.com/support MDC_UEI15W.C17 Page 3 of 17 OV protection method Voltage Out- put Range Ripple/Noise (20 MHz 8 bandwidth) Line/Load Regulation Efficiency UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters (4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR- ABSOLUTE MAXIMUM RATINGS 332 Method 1, Case 3, ground fixed conditions, Tpcboard=+25 deg.C, full load, Volts Max. continuous 36 VDC natural air convection. Q12 models Volts, transient 100mS 50 VDC Input (5) The On/Off Control is normally controlled by a switch. But it may also be Voltage Volts Max. continuous 75 VDC driven with external logic or by applying appropriate external voltages which are Q48 models Volts, transient 100mS 100 VDC referenced to Input Common. The On/Off Control Input should use either an open collector or open drain transistor. Volts, Min. –0.3 On/Off control, referred to –Vin (6) Output current limiting begins when the output voltage degrades Volts, Max. 15 approximately 2% from the selected setting. See fuse section Input Reverse Polarity Protection (7) The outputs are not intended to sink appreciable reverse current. This may Vout nom. +20% Output Overvoltage, Volts Max. damage the outputs. Current-limited, see specs Output Current, sustained short circuit (8) Output noise may be further reduced by adding an external filter. See I/O Fil- Range, Min. ºC -55 tering and Noise Reduction. Storage Temperature Max. ºC +125 (9) All models are fully operational and meet published specifications, including “cold start” at –40°C. Absolute Maximum Ratings Root Models Conditions Minimum Typical Maximum Units Absolute maximums are stress ratings. Exposure of devices to greater than any All UEI15 Q12 Start up at –40°C 10 10.5 11 Vdc of these conditions may adversely affect long-term reliability. Proper operation (10) Regulation specifications describe the deviation as the line input voltage under conditions other than those listed in the Performance/Functional Specifi- or output load current is varied from a nominal midpoint value to either extreme. cations is neither implied nor recommended. (11) The output overvoltage protection is automatic recovery after fault removal. The overvoltage may occur either from internal failure or from an SPECIFICATION NOTES external forcing voltage as in a shared power system. (1) All models are tested and specified with external capacitors listed in the (12) Output current limit and short circuit protection is non-latching. When the table below. The external capacitors listed below are ONLY for establishing test overcurrent fault is removed, the converter will immediately recover. specifications. They are required for our test fixtures and equipment. Your applica- (13) Do not exceed maximum power specifications when adjusting the output tion may not need them. The converter is stable with no external capacitors but trim. Murata Power Solutions strongly recommends external caps. All caps are low-ESR (14) At zero output current, the output may contain low frequency components types. Where two or more capacitors are listed, these are connected in parallel. All which exceed the ripple specification. The output may be operated indefinitely caps should mount close to the DC/DC using short leads. with no load. All specifications are typical unless noted. General conditions for Specifica- (15) If reverse polarity is accidentally applied to the input, to ensure reverse in- tions are +25 deg.C, Vin=nominal, Vout=nominal, full load. Adequate airflow must put protection with full output load, always connect an external input fuse in series be supplied for extended testing under power. with the +Vin input. Use approximately twice the full load input current rating at (2) Input Ripple Current is tested and specified over a 5 Hz to 20 MHz band- minimum input voltage. width. Input filtering is Cin=33 µF, 100V tantalum, Cbus=220 µF, 100V electro- (16) “Hiccup” operation repeatedly attempts to restart the converter with a lytic, Lbus=12 µH. brief, full-current output. If the overcurrent condition still exists, the restart current (3) Note that Maximum Power Derating curves indicate an average current at will be removed and then tried again. This short current pulse prevents over- nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC heating and damaging the converter. Once the fault is removed, the converter converter will tolerate brief full current outputs if the total RMS current over time immediately recovers normal operation. does not exceed the Derating curve. All Derating curves are presented at sea level (17) On model UEI15-050-Q48, if Vin <20V, output trim may only be adjusted altitude. Be aware of reduced power dissipation with increasing density altitude. downwards from +5.0V (more negative). (18) Typical values shown. For minimum and maximum values see table below. INPUT/OUTPUT EXTERNAL TEST CAPACITORS Root Models Conditions Minimum Maximum Units All UEI15 Q12 @+25°C 8.8 10 Vdc Model Input Capacitor Output Capacitor(s) CAUTION: This product is not internally fused. To comply with safety UEI15-033-Q12 100 µF 1 µF & 10 µF agency certifications and to avoid injury to personnel or equipment, the user UEI15-033-Q48 4.7 µF ceramic 1 µF & 10 µF must connect an external fast-blow fuse to the input terminals. See fuse UEI15-050-Q12 100 µF 1 µF & 10 µF information. UEI15-050-Q48 4.7 µF ceramic 1 µF & 10 µF (19) All models require 10% of Imax minimum output load to meet specifi- UEI15-120-Q12 100 µF 1 µF & 10 µF cations. However, they will not be damaged at zero output load. UEI15-120-Q48 4.7 µF ceramic 1 µF & 10 µF UEI15-150-Q12 100 µF 1 µF & 10 µF UEI15-150-Q48 4.7 µF ceramic 1 µF & 10 µF www.murata-ps.com/support MDC_UEI15W.C17 Page 4 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters PERFORMANCE DATA UEI15-033-Q12 Effi ciency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @sea level (Vin = 12V or 24V, airfl ow from input to output) 90 5.5 85 5.0 80 4.5 Vin = 36 V Na a atural Convection tural Convection 75 Vin = 24 V 4.0 70 Vin = 18 V 3.5 Vin = 9 V 65 3.0 60 55 2.5 50 2.0 0 0.5 1 1.5 2 2.5 3 3.5 4 40 45 50 55 60 65 70 75 80 85 Load Current (Amps) A A Am mbient temperature (°C) UEI15-033-Q48 Effi ciency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @sea level (Vin = 24V, airfl ow from input to output) 90 5.10 4.90 85 Na a atural Convection tural Convection 4.70 0.5 m/s (100 LFM) 80 1.0 m/s (200 LFM) 1.5 m/s (300 1.5 m/s (300 1.5 m/s (300 1.5 m/s (300 1.5 m/s (300 LFM) M) 4.50 75 Vin = 75 V 4.30 70 Vin = 48 V 4.10 Vin = 18 V 65 3.90 60 3.70 3.50 55 40 45 50 55 60 65 70 75 80 85 A A Am mbient Temperature (°C) 50 1 2 3 4 5 Load Current (Amps) UEI15-033-Q48 Maximum Current Temperature Derating @sea level (Vin = 48V, airfl ow from input to output) 5.20 5.00 Na a atural Convection tural Convection 0.5 m/s (100 LFM) 4.80 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 4.60 2.0 m/s (400 2.0 m/s (400 2.0 m/s (400 2.0 m/s (400 LFM) M) 4.40 4.20 4.00 3.80 40 45 50 55 60 65 70 75 80 85 A A Am mbient temperature (°C) www.murata-ps.com/support MDC_UEI15W.C17 Page 5 of 17 Efficiency (%) Efficiency (%) Output Current ( ( (A Amps) Output Current (Amps) Output Current ( ( (A Amps) UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters PERFORMANCE DATA UEI15-050-Q12 Efficiency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (Vin = 24V, airflow is from pin 1 to pin 3) 100 4 90 80 3 0.33 m/s (65 LFM) 70 Vin = 36 V 60 2 Vin = 24 V 50 Vin = 18 V 40 Vin = 9 V 1 30 20 0 20 25 30 35 40 45 50 55 60 65 70 75 80 85 10 0.25 0.5 0.75 1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 Ambient Temperature (°C) Load Current (Amps) UEI15-050-Q48 Efficiency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (Vin = 24V or 48V, airflow is from input to output) 100 3.20 90 3.10 80 70 3.00 Natural Convection 60 Vin = 75 V 2.90 50 Vin = 36 V 2.80 40 Vin = 24 V 30 2.70 Vin = 18 V 20 2.60 10 2.50 0 40 45 50 55 60 65 70 75 80 85 0 0.5 1 1.5 2 2.5 3 Ambient Temperature (°C) Load Current (Amps) UEI15-120-Q12 Efficiency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (Vin = 24V, airflow is from pin 1 to pin 3) 90 1.5 85 0.33 m/s (65 LFM) 80 1 Vin = 36 V 75 Vin = 24 V Vin = 18 V 70 0.5 Vin = 9 V 65 0 60 20 25 30 35 40 45 50 55 60 65 70 75 80 85 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 Ambient Temperature (°C) Load Current (Amps) www.murata-ps.com/support MDC_UEI15W.C17 Page 6 of 17 Efficiency (%) Efficiency (%) Efficiency (%) Output Current (Amps) Output Current (Amps) Output Current (Amps) UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters PERFORMANCE DATA UEI15-120-Q48 Efficiency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (Vin = 24V or 48V, airflow is from pin 2 to pin 1) 90 88 1.3 86 Natural Convection 1.2 84 Vin = 75 V 1.1 Vin = 48 V 82 1.0 Vin = 24 V 80 Vin = 18 V 0.9 78 0.8 76 0.7 74 0.6 0.5 72 40 45 50 55 60 65 70 75 80 85 70 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3 Ambient Temperature (°C) Load Current (Amps) UEI15-150-Q12 Efficiency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (Vin = 12V and 24V, airflow is from input to output) 90 1.15 88 1.10 Natural Convection 86 1.05 84 1.00 82 0.95 Vin = 36 V 80 Vin = 24 V 0.90 Vin = 9 V 78 0.85 76 0.80 40 45 50 55 60 65 70 75 80 85 74 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 Ambient Temperature (°C) Load Current (Amps) UEI15-150-Q48 Efficiency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (Vin = 24V and 48V, airflow is from input to output) 95 1.15 90 1.10 Natural Convection 85 1.05 80 1.00 75 0.95 Vin = 75 V 70 Vin = 48 V 0.90 Vin = 24 V 65 Vin = 18 V 0.85 60 0.80 0.07 0.18 0.28 0.38 0.49 0.59 0.69 0.80 0.90 1.00 1.10 40 45 50 55 60 65 70 75 80 85 Load Current (Amps) Ambient Temperature (°C) www.murata-ps.com/support MDC_UEI15W.C17 Page 7 of 17 Efficiency (%) Efficiency (%) Efficiency (%) Output Current (Amps) Output Current (Amps) Output Current (Amps) UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters MECHANICAL SPECIFICATIONS, OPEN FRAME TOP VIEW PHYSICAL CHARACTERISTICS 27.9 Pin Material Copper alloy Case 75 1.10 Pin Diameter 0.04˝ (1.016mm) Pin Finish Gold plate PIN #1 Through Hole Pin Material Copper alloy Nickel subplate 50 µ-inches TH Pin Plating Metal and Thickness Gold overplate 5 µ-inches 24.4 Weight 0.352 oz./10 grams 0.96 EN55022/CISPR22 (see note 1) (Requires Electromagnetic Interference external filter) Flammability Rating UL 94V-0 Certified to UL/cUL 60950-1, CAN/CSA- Safety C22.2-60950-1, IEC/EN 60950-1, 2nd edition SIDE VIEW MOUNTING PLANE 8.4 0.33 .040±.002 .071 .002 SHOULDER 6X AT PINS 1-6 BOTTOM VIEW END VIEW C L #6 10.16 0.475 INPUT/OUTPUT CONNECTIONS #5 0.400 REF Pin Function .30 #2 1 +Vin 2 -Vin #4 #1 3 +Vout 5.08 10.16 4 Output Trim 0.200 0.400 5 -Vout C C L L 6 On/Off Control* #3 *The Remote On/Off can be provided 10.16 with either positive (P suffix) or nega- 0.400 0.41 tive (N suffix) logic 2.54 0.100 0.15 TYP RECOMMENDED 6.3 PRI-SEC BARRIER Dimensions are in inches (mm shown for ref. only). 0.25 0.58 Third Angle Projection 20.32 0.800 Standard pin length is shown. Please refer to the Ordering Guide for alternate pin lengths. Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 1˚ Components are shown for reference only. www.murata-ps.com/support MDC_UEI15W.C17 Page 8 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters SHIPPING TRAYS AND BOXES, THROUGH-HOLE MOUNT Anti-static foam Label Label Each tray is 6 x 5 units (30 units per tray) SHIPPING TRAY DIMENSIONS UEI modules are supplied in a 30-piece (6 x 5) shipping tray. The tray is an anti-static closed-cell polyethylene foam. Dimensions are shown below. [9.92] 252.0 6.4 Typ 6.4 28.4 18.0 Typ Typ 5x 38.1 25.4 252.0 Typ 252.0 [9.92] Ref 190.5 Ref Ref 252.0 R 6.4 A A Typ 9.5 deep 4x 44.5 19.1 Ref 177.8 Ref 22.9 Ref 9.5 [.38 in] Pocket 19.1 [.75 in] Depth SECTION A-A Notes: 1. Material: Dow 220 antistat ethafoam (Density: 34-35 kg/m3) 2. Dimensions: 252 x 252 x 19.1 mm 6 x 5 array (30 per tray) 3. All dimensions in millimeters [inches] 4. Tolerances unless otherwise specified: +1/-0 www.murata-ps.com/support MDC_UEI15W.C17 Page 9 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters MECHANICAL SPECIFICATIONS, SURFACE MOUNT PACKAGE (MSL RATING 2) TOP VIEW 27.9 Dimensions are in inches (mm shown for ref. only). INPUT/OUTPUT CONNECTIONS 1.10 Pin Function Third Angle Projection 1 +Vin 2 -Vin PIN #1 3 +Vout 4 Output Trim 5 -Vout 24.4 Tolerances (unless otherwise specified): 6 On/Off Control* .XX ± 0.02 (0.5) 0.96 *The Remote On/Off can be provided .XXX ± 0.010 (0.25) with either positive (P suffix) or nega- Angles ± 1˚ tive (N suffix) logic Components are shown for reference only. SIDE VIEW MOUNTING PLANE .093 TYP BOTTOM VIEW END VIEW C L #6 0.33±.03 10.16 [8.4±0.8] #5 0.400 #2 2.54 #4 #1 0.100 10.16 0.400 C C L L #3 10.16 .093 2.54 0.400 0.100 20.32 0.13 0.800 REF www.murata-ps.com/support MDC_UEI15W.C17 Page 10 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters MECHANICAL SPECIFICATIONS, SURFACE MOUNT PACKAGE 29.0 1.14 C L 2.54 3 10.16 0.100 0.400 25.4 1 1.00 C L 4 2 10.16 0.400 2.54 0.100 5 6 2.60 ±0.25 6X .102 ±.010 20.32 0.800 RECOMMENDED SMT PAD LAYOUT SURFACE MOUNT TAPE AND REEL INFORMATION (MSL RATING 2) PACKAGING CONFORMS TO EIA-481 CONVERTERS SHIPPING IN QUANTITIES OF 100 PER REEL NOTE: The SMT package has an MSL 2 rating. 3.00 5.0mm PICK & 2.00 0.118 PLACE LOCATION 0.079 23.10 0.909 56.0 2.20 32.00 DIRECTION OF FEED 1.260 13.0 COVER TAPE R.256 9.27 Dimensions in inches [mm] 0.365 SURFACE MOUNT TAPE AND REEL www.murata-ps.com/support MDC_UEI15W.C17 Page 11 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters put voltage regulation. Since real-world voltage sources have finite impedance, TECHNICAL NOTES performance is improved by adding external filter components. Sometimes only Input Fusing a small ceramic capacitor is sufficient. Since it is difficult to totally characterize Certain applications and/or safety agencies may require fuses at the inputs of all applications, some experimentation may be needed. Note that external input power conversion components. Fuses should also be used when there is the capacitors must accept high speed switching currents. possibility of sustained input voltage reversal which is not current-limited. For Because of the switching nature of DC/DC converters, the input of these greatest safety, we recommend a fast blow fuse installed in the ungrounded converters must be driven from a source with both low AC impedance and input supply line. adequate DC input regulation. Performance will degrade with increasing input The installer must observe all relevant safety standards and regulations. For inductance. Excessive input inductance may inhibit operation. The DC input safety agency approvals, install the converter in compliance with the end-user regulation specifies that the input voltage, once operating, must never degrade safety standard, i.e. IEC/EN/UL 60950-1. below the Shut-Down Threshold under all load conditions. Be sure to use adequate trace sizes and mount components close to the converter. Input Reverse-Polarity Protection If the input voltage polarity is reversed, an internal diode will become forward I/O Filtering, Input Ripple Current and Output Noise biased and likely draw excessive current from the power source. If this source All models in this converter series are tested and specified for input reflected is not current-limited or the circuit appropriately fused, it could cause perma- ripple current and output noise using designated external input/output compo- nent damage to the converter. nents, circuits and layout as shown in the figures below. External input capaci- tors (Cin in the figure) serve primarily as energy storage elements, minimizing Input Under-Voltage Shutdown and Start-Up Threshold line voltage variations caused by transient IR drops in the input conductors. Under normal start-up conditions, converters will not begin to regulate properly Users should select input capacitors for bulk capacitance (at appropriate until the ramping-up input voltage exceeds and remains at the Start-Up frequencies), low ESR and high RMS ripple current ratings. In the figure below, Threshold Voltage (see Specifications). Once operating, converters will not the Cbus and Lbus components simulate a typical DC voltage bus. Your specific turn off until the input voltage drops below the Under-Voltage Shutdown Limit. system configuration may require additional considerations. Please note that the Subsequent restart will not occur until the input voltage rises again above the values of Cin, Lbus and Cbus will vary according to the specific converter model. Start-Up Threshold. This built-in hysteresis prevents any unstable on/off opera- In critical applications, output ripple and noise (also referred to as periodic tion at a single input voltage. and random deviations or PARD) may be reduced by adding filter elements Users should be aware however of input sources near the Under-Voltage such as multiple external capacitors. Be sure to calculate component tempera- Shutdown whose voltage decays as input current is consumed (such as capaci- ture rise from reflected AC current dissipated inside capacitor ESR. tor inputs), the converter shuts off and then restarts as the external capacitor recharges. Such situations could oscillate. To prevent this, make sure the oper- ating input voltage is well above the UV Shutdown voltage AT ALL TIMES. Start-Up Time TO CURRENT Assuming that the output current is set at the rated maximum, the VIN to VOUT OSCILLOSCOPE PROBE Start-Up Time (see Specifications) is the time interval between the point when +VIN the ramping input voltage crosses the Start-Up Threshold and the fully loaded LBUS + regulated output voltage enters and remains within its specified accuracy band. – VIN CBUS CIN Actual measured times will vary with input source impedance, external input + – capacitance, input voltage slew rate and final value of the input voltage as it appears at the converter. -VIN These converters include a soft start circuit to moderate the duty cycle of its CIN = 33µF, ESR < 700mΩ @ 100kHz CBUS = 220µF, ESR < 100mΩ @ 100kHz PWM controller at power up, thereby limiting the input inrush current. LBUS = 12µH The On/Off Remote Control interval from On command to VOUT regulated Figure 2. Measuring Input Ripple Current assumes that the converter already has its input voltage stabilized above the Start-Up Threshold before the On command. The interval is measured from the On command until the output enters and remains within its specified accuracy band. The specification assumes that the output is fully loaded at maximum Floating Outputs rated current. Similar conditions apply to the On to VOUT regulated specification Since these are isolated DC/DC converters, their outputs are “floating” with such as external load capacitance and soft start circuitry. respect to their input. The essential feature of such isolation is ideal ZERO CURRENT FLOW between input and output. Real-world converters however do Input Source Impedance exhibit tiny leakage currents between input and output (see Specifications). These converters will operate to specifications without external components, These leakages consist of both an AC stray capacitance coupling component assuming that the source voltage has very low impedance and reasonable in- www.murata-ps.com/support MDC_UEI15W.C17 Page 12 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters MPS makes Characterization measurements in a closed cycle wind tunnel with calibrated airflow. We use both thermocouples and an infrared camera system to observe thermal performance. As a practical matter, it is quite diffi- cult to insert an anemometer to precisely measure airflow in most applications. Sometimes it is possible to estimate the effective airflow if you thoroughly un- derstand the enclosure geometry, entry/exit orifice areas and the fan flowrate SCOPE RLOAD C1 C2 specifications. If in doubt, contact MPS to discuss placement and measurement techniques of suggested temperature sensors. CAUTION: If you routinely or accidentally exceed these Derating guidelines, the converter may have an unplanned Over Temperature shut down. Also, these graphs are all collected at slightly above Sea Level altitude. Be sure to reduce C1 = 1µF the derating for higher density altitude. C2 = 10µF LOAD 2-3 INCHES (51-76mm) FROM MODULE Output Overvoltage Protection Figure 3. Measuring Output Ripple and Noise (PARD) This converter monitors its output voltage for an over-voltage condition using an on-board electronic comparator. The signal is optically coupled to the pri- and a DC leakage resistance. When using the isolation feature, do not allow mary side PWM controller. If the output exceeds OVP limits, the sensing circuit the isolation voltage to exceed specifications. Otherwise the converter may will power down the unit, and the output voltage will decrease. After a time-out be damaged. Designers will normally use the negative output (-Output) as period, the PWM will automatically attempt to restart, causing the output volt- the ground return of the load circuit. You can however use the positive output age to ramp up to its rated value. It is not necessary to power down and reset (+Output) as the ground return to effectively reverse the output polarity. the converter for the this automatic OVP-recovery restart. Minimum Output Loading Requirements If the fault condition persists and the output voltage climbs to excessive levels, These converters employ a synchronous rectifier design topology. Models the OVP circuitry will initiate another shutdown cycle. This on/off cycling is referred UEI15-033-Q12, UEI15-120-Q12, and UEI15-050-Q12 require 10% minimum to as “hiccup” mode. It safely tests full current rated output voltage without damag- load to meet specifications. Operation under less than 10% load may slightly ing the converter. increase regulation, ripple, and noise. Output Fusing Thermal Shutdown The converter is extensively protected against current, voltage and temperature To prevent many over temperature problems and damage, these converters extremes. However your output application circuit may need additional protec- include thermal shutdown circuitry. If environmental conditions cause the tion. In the extremely unlikely event of output circuit failure, excessive voltage temperature of the DC/DC’s to rise above the Operating Temperature Range could be applied to your circuit. Consider using an appropriate fuse in series up to the shutdown temperature, an on-board electronic temperature sensor with the output. will power down the unit. When the temperature decreases below the turn-on Output Current Limiting threshold, the converter will automatically restart. There is a small amount of As soon as the output current increases to approximately 125% to 150% of hysteresis to prevent rapid on/off cycling. its maximum rated value, the DC/DC converter will enter a current-limiting CAUTION: If you operate too close to the thermal limits, the converter may shut mode. The output voltage will decrease proportionally with increases in output down suddenly without warning. Be sure to thoroughly test your application to current, thereby maintaining a somewhat constant power output. This is com- avoid unplanned thermal shutdown. monly referred to as power limiting. Temperature Derating Curves Current limiting inception is defined as the point at which full power falls The graphs in this data sheet illustrate typical operation under a variety of below the rated tolerance. See the Performance/Functional Specifications. Note conditions. The Derating curves show the maximum continuous ambient air particularly that the output current may briefly rise above its rated value. This temperature and decreasing maximum output current which is acceptable enhances reliability and continued operation of your application. If the output under increasing forced airflow measured in Linear Feet per Minute (“LFM”). current is too high, the converter will enter the short circuit condition. Note that these are AVERAGE measurements. The converter will accept brief increases in temperature and/or current or reduced airflow as long as the aver- Output Short Circuit Condition age is not exceeded. When a converter is in current-limit mode, the output voltage will drop as the output current demand increases. If the output voltage drops too low, the Note that the temperatures are of the ambient airflow, not the converter magnetically coupled voltage used to develop primary side voltages will also itself which is obviously running at higher temperature than the outside air. drop, thereby shutting down the PWM controller. Following a time-out period, Also note that “natural convection” is defined as very flow rates which are not the PWM will restart, causing the output voltage to begin ramping up to its ap- using fan-forced airflow. Depending on the application, “natural convection” is propriate value. If the short-circuit condition persists, another shutdown cycle usually about 30-65 LFM but is not equal to still air (0 LFM). will initiate. This on/off cycling is called “hiccup mode”. The hiccup cycling www.murata-ps.com/support MDC_UEI15W.C17 Page 13 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters reduces the average output current, thereby preventing excessive internal temperatures. A short circuit can be tolerated indefinitely. +VOUT −VIN Trimming the Output Voltage The Trim input to the converter allows the user to adjust the output voltage over the rated trim range (please refer to the Specifications). In the trim equa- tions and circuit diagrams that follow, trim adjustments use either a trimpot or ON/OFF TRIM LOAD a single fixed resistor connected between the Trim input and either the positive CONTROL R TRIM UP or negative output terminals. (On some converters, an external user-supplied precision DC voltage may also be used for trimming). Trimming resistors should have a low temperature coefficient (±100 ppm/deg.C or less) and be mounted close to the converter. Keep leads short. If the trim function is not used, leave +VIN −VOUT the trim unconnected. With no trim, the converter will exhibit its specified output voltage accuracy. Figure 6. Trim adjustments to increase Output Voltage using a Fixed Resistor +VOUT CAUTION: Be careful of external electrical noise. The Trim input is a senstive −VIN input to the converter’s feedback control loop. Excessive electrical noise may cause instability or oscillation. Keep external connections short to the Trim input. Use shielding if needed. 5-22 7 ON/OFF Trim Equations TRIM LOAD TURNS CONTROL Trim Up Trim Down Trim and +VOUT> +VIN −VOUT UEI15-033-Q12, Q48 Figure 4. Trim adjustments using a trimpot 12775 5110 (Vo - 2.5) – 2050 – 2050 RT (Ω) = RT (Ω) = UP DOWN VO – 3.3 3.3 – VO UEI15-050-Q12, Q48 +VOUT 12775 5110 (Vo - 2.5) −VIN – 2050 RT (Ω) = – 2050 RT (Ω) = DOWN UP VO – 5 5 – VO UEI15-120-Q12, Q48 10000 (Vo-2.5) 25000 ON/OFF TRIM LOAD – 5110 – 5110 RT (Ω) = RT (Ω) = UP DOWN 12 – VO CONTROL RTRIM DOWN VO – 12 UEI15-150-Q12, Q48 10000 (Vo-2.5) 25000 RT (Ω) = – 5110 RT (Ω) = – 5110 DOWN UP VO – 15 15 – VO −VOUT +VIN Figure 5. Trim adjustments to decrease Output Voltage using a Fixed Resistor Where Vo = Desired output voltage. Adjustment accuracy is subject to resis- tor tolerances and factory-adjusted output accuracy. Mount trim resistor close There are two CAUTIONs to be aware for the Trim input: to converter. Use short leads. CAUTION: To avoid unplanned power down cycles, do not exceed EITHER the Remote On/Off Control maximum output voltage OR the maximum output power when setting the trim. On the input side, a remote On/Off Control can be ordered with either logic type. Be particularly careful with a trimpot. If the output voltage is excessive, the Positive-logic models are enabled when the On/Off pin is left open or is OVP circuit may inadvertantly shut down the converter. If the maximum power pulled high to +15V max. with respect to –VIN. Some models will also turn on is exceeded, the converter may enter current limiting. If the power is exceeded at lower intermediate voltages (see Specifications). Positive-logic devices are for an extended period, the converter may overheat and encounter overtem- perature shut down. www.murata-ps.com/support MDC_UEI15W.C17 Page 14 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters disabled when the On/Off is grounded or brought to within a low voltage (see Through-hole Soldering Guidelines Specifications) with respect to –VIN. Murata Power Solutions recommends the TH soldering specifications below when install- ing these converters. These specifications vary depending on the solder type. Exceeding Negative-logic devices are on (enabled) when the On/Off is grounded or these specifications may cause damage to the product. Your production environment may brought to within a low voltage (see Specifications) with respect to –VIN. The differ; therefore please thoroughly review these guidelines with your process engineers. device is off (disabled) when the On/Off is left open or is pulled high to +15Vdc Wave Solder Operations for through-hole mounted products (THMT) max. with respect to –VIN. For Sn/Ag/Cu based solders: Dynamic control of the On/Off function should be able to sink appropriate Maximum Preheat Temperature 115° C. signal current when brought low and withstand appropriate voltage when Maximum Pot Temperature 270° C. brought high. Be aware too that there is a finite time in milliseconds (see Specifications) between the time of On/Off Control activation and stable, Maximum Solder Dwell Time 7 seconds regulated output. This time will vary slightly with output load type and current For Sn/Pb based solders: and input conditions. Maximum Preheat Temperature 105° C. There are three CAUTIONs for the On/Off Control: Maximum Pot Temperature 250° C. Maximum Solder Dwell Time 6 seconds CAUTION: To retain full output circuit isolation, control the On/Off from the in- put side ONLY. If you must control it from circuits in the output, use some form SMT Reflow Soldering Guidelines of optoisolation to the On/Off Control. This latter condition is unlikely because The surface-mount reflow solder profile shown below is suitable for SAC305 type lead- the device controlling the On/Off would have to remain powered on and not be free solders. This graph should be used only as a guideline. Many other factors influence powered from the converter. the success of SMT reflow soldering. Since your production environment may differ, please thoroughly review these guidelines with your process engineers. CAUTION: While it is possible to control the On/Off with external logic if you carefully observe the voltage levels, the preferred circuit is either an open drain/open collector transistor, a switch or a relay (which can thereupon be controlled by logic). CAUTION: Do not apply voltages to the On/Off pin when there is no input power voltage. Otherwise the converter may be permanently damaged. + Vcc ON/OFF CONTROL CONTROL -VIN Figure 7. Driving the On/Off Control Pin (suggested circuit) www.murata-ps.com/support MDC_UEI15W.C17 Page 15 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters Emissions Performance [3] Conducted Emissions Test Results Murata Power Solutions measures its products for radio frequency emissions against the EN 55022 and CISPR 22 standards. Passive resistance loads are employed and the output is set to the maximum voltage. If you set up your own emissions testing, make sure the output load is rated at continuous power while doing the tests. The recommended external input and output capacitors (if required) are included. Please refer to the fundamental switching frequency. All of this information is listed in the Product Specifi cations. An external discrete fi lter is installed and the circuit diagram is shown below. UEI15-050-Q12P-C EMI 15W Test Card Resistive 24Vdc in, 5Vout, 3Amps Load UUT V+ Resistive Vin + Vout + Black C1 C1 C1 C1 C1 C1 C1 C1 C1 C2 Load inside a L1 L2 metal container V- Graph 1. Conducted emissions performance, Vin - Vout - CISPR/EN55022, Class B, full load, fi ltered Figure 8. Conducted Emissions Test Circuit [1] Conducted Emissions Parts List Reference Part Number Description Vendor L2 PE-62913 1mH, 6A Pulse L1 500uH,10A, MPS 500uH,10A Murata C1 Ceramic 2.2ufd, 100V Murata C2 Electrolytic Capacitor 33ufd, 100V Panasonic [2] Conducted Emissions Test Equipment Used Rohde & Schwarz EMI Test Receiver (9KHz – 1000MHz) ESPC Rohde & Schwarz Software ESPC-1 Ver. 2.20 HP11947A Transient Limiter (Agilent) Graph 1. Conducted emissions performance, OHMITE 25W – Resistor combinations CISPR/EN55022, Class B, full load, unfi ltered DC Source Power Supply – Kikisui Model PAD 55-6L [4] Layout Recommendations Most applications can use the fi ltering which is already installed inside the converter or with the addition of the recommended external capacitors. For greater emissions suppression, consider additional fi lter components and/or shielding. Emissions performance will depend on the user’s PC board layout, the chassis shielding environment and choice of external components. Please refer to Application Note GEAN02 for further discussion. Since many factors affect both the amplitude and spectra of emissions, we recommend using an engineer who is experienced at emissions suppression. www.murata-ps.com/support MDC_UEI15W.C17 Page 16 of 17 UEI15 Series Isolated Wide Input Range 15-Watt DC-DC Converters Vertical Wind Tunnel Murata Power Solutions employs a computer controlled custom-designed closed loop vertical wind tunnel, infrared video camera system, and test instrumentation for accurate airfl ow and heat dissipation analysis of power products. The system includes IR Transparent a precision low fl ow-rate anemometer, variable speed fan, power optical window Variable supply input and load controls, temperature gauges, and adjust- Unit under speed fan able heating element. test (UUT) IR Video The IR camera monitors the thermal performance of the Unit Camera Under Test (UUT) under static steady-state conditions. A special optical port is used which is transparent to infrared wavelengths. Both through-hole and surface mount converters are soldered down to a host carrier board for realistic heat absorption and spreading. Both longitudinal and transverse airfl ow studies are Heating possible by rotation of this carrier board since there are often element signifi cant differences in the heat dissipation in the two airfl ow Precision directions. The combination of adjustable airfl ow, adjustable low-rate ambient heat, and adjustable Input/Output currents and voltages anemometer 3” below UUT mean that a very wide range of measurement conditions can be studied. The collimator reduces the amount of turbulence adjacent Ambient to the UUT by minimizing airfl ow turbulence. Such turbulence temperature infl uences the effective heat transfer characteristics and gives sensor false readings. Excess turbulence removes more heat from some surfaces and less heat from others, possibly causing uneven Airflow overheating. collimator Both sides of the UUT are studied since there are different thermal gradients on each side. The adjustable heating element and fan, built-in temperature gauges, and no-contact IR camera mean that power supplies Figure 9. Vertical Wind Tunnel are tested in real-world conditions. This product is subject to the following operating requirements Murata Power Solutions, Inc. and the Life and Safety Critical Application Sales Policy: 129 Flanders Rd., Westborough, MA 01581 U.S.A. Refer to: http://www.murata-ps.com/requirements/ ISO 9001 and 14001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. © 2018 Murata Power Solutions, Inc. www.murata-ps.com/support MDC_UEI15W.C17 Page 17 of 17

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the UEI15-120-Q48P-C?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

DC/DC 8-36VIN/3.3VOUT .5A SIP 7803SR-C

product

DC/DC 8-36VIN/3.3VOUT .5A HSIP 7803SRH-C

product

DC/DC 8-36VIN/5VOUT .5A SIP 7805SR-C

product

DC/DC 8-36VIN/5VOUT .5A HSIP 7805SRH-C

product

4.8 W, 15 -36 VDC VIN, SINGLE OUTPUT, 12 VDC@0.4 A DC-DC CONVERTER 7812SR-C

product

4.8 W, 15 -36 VDC VIN, SINGLE OUTPUT, 12 VDC@0.4 A DC-DC CONVERTER 7812SRH-C