Electronics Finder Manufacturers M MURATA POWER SOLUTIONS UEI30-033-Q48N-C
About product Specifications Datasheet FAQ

MURATA POWER SOLUTIONS UEI30-033-Q48N-C

Image of MURATA POWER SOLUTIONS UEI30-033-Q48N-C

Description

29.7 W, 18 -75 VDC VIN, SINGLE OUTPUT, 3.3 VDC@9 A DC-DC CONVERTER
UEI30-033-Q48N-C

Part Number

UEI30-033-Q48N-C

Price

Request Quote

Manufacturer

MURATA POWER SOLUTIONS

Lead Time

Request Quote

Category

Capacitors »  DC-DC Converter

Specifications

Manufacturer

Murata Power Solutions

Manufacturers Part #

UEI30-033-Q48N-C

Lead Time

30 Week Lead Time

Series

UEI30

Factory Pack Quantity

21

Cooling Method

Convection

Dimensions

1.92 x 0.92 x 0.35"

Efficiency

90%

Input Voltage Nominal

48 VDC

Isolation

2250 VDC

Mechanical Style

Isolated

Mounting

Through Hole

Number of Outputs

1

Operating Temperature

- 40 to + 85°C

Output Amps 1

9 A

Output Voltage V1 Nominal

3.3 VDC

Power

29.7 W

Subcategory

DC-DC Converter

Datasheet

pdf file

mdc_uei-30w.pdf

479 KiB

Extracted Text

UEI30 Series www.murata-ps.com 30W Isolated Wide-Range DC-DC Converters Featuring a full 30 Watt output in 1.8 square inches of board area, the UEI series isolated DC/DC converter family offers efficient regulated DC power for printed circuit board mounting. T Typical unit ypical unit FEATURES PRODUCT OVERVIEW  Small footprint DC/DC converter, ideal for high Wide range 4:1 inputs on the 0.92" x 1.92" x 0.35" programmable logic and FPGA’s. No minimum current applications converter are either 9 to 36 Volts DC (Q12 models) load is required. For systems requiring controlled  0.92" x 1.92" x 0.35" open frame package or 18 to 75 Volts DC (Q48 models), ideal for startup/shutdown, an external switch, transistor battery-powered and telecom equipment. Fixed or digital logic may be used to activate the remote  Wide range input voltages 9-36 and 18-75Vdc output voltages from 3.3 VDC to 15 VDC are tightly On/Off control.  Assembly and attachment for RoHS-6 hazardous regulated and may be trimmed within ±10% A wealth of self-protection features avoid both substance compliance of nominal output. Applications include small converter and external circuit problems. These  Isolation up to 2250 VDC (basic), Q48 models instruments, computer-based systems, data com- include input undervoltage lockout and overtem-  Up to 30W total output power with munications equipment, remote sensor systems, perature shutdown. The outputs current limit using overtemperature shutdown vehicle and portable electronics. the “hiccup” autorestart technique and the outputs  High effi ciency synchronous rectifi er forward The UEI 30W Series includes full magnetic may be short-circuited indefi nitely. Additional topology and optical isolation up to 2250 Volts DC (basic features include output overvoltage and reverse insulation), Q48 models. For connection to digital conduction elimination.  Stable no-load operation with no required systems, the outputs offer fast settling to current external components The synchronous rectifi er forward topology step loads and tolerance of higher capacitive offers high effi ciency for minimal heat buildup  –40 to +85°C temperature range; see derating loads. Excellent ripple and noise specifi cations and “no fan” operation.  Certifi ed to UL60950-1, CSA-C22.2 No. 234 assure compatibility to circuits using CPU’s, ASIC’s, safety approvals, and CE marking on 48V input only SIMPLIFIED SCHEMATIC  Extensive self-protection shut down features  RoHS-6 hazardous substance compliant +VOUT +VIN GATE DRIVE –VIN –VOUT ISOLATION BARRIER On/Off Control Control TRIM OPTO Reference, trim & ISOLATION Error Amplifier Typical topology is shown. For full details go to www.murata-ps.com/rohs (48V input only) www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 1 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Output Input Open Frame Effi ciency Package, C80 Power R/N (mVp-p) Regulation (Max.) VIN IIN, VOUT IOUT Range IIN, full Nom. no load (V) (A) (V) load (A) Min. Typ. (W) Typ. Max. Line Load Case Pinout (V) (mA)  Part Number UEI30-033-Q12P-C 3.3 9 29.7 25 35 ±0.2% ±0.25% 24 9-36 130 1.39 87.3% 89% C80 P21 UEI30-033-Q48N-C 3.3 9 29.7 50 75 ±0.2% ±0.25% 48 18-75 50 0.69 87% 89.5% C80 P21 UEI30-050-Q12P-C 5 6 30 35 50 ±0.2% ±0.2% 24 9-36 130 1.4 88% 89.5% C80 P21 UEI30-050-Q48N-C 5 6 30 25 50 ±0.1% ±0.2% 48 18-75 130 0.7 87% 88.8% C80 P21 UEI30-120-Q12P-C 12 2.5 30 60 120 ±0.2% ±0.1% 24 9-36 75 1.4 87.5% 89% C80 P21 UEI30-120-Q48N-C 12 2.5 30 30 60 ±0.2% ±0.1% 48 18-75 40 0.7 87.5% 89% C80 P21 UEI30-150-Q12P-C 15 2 30 40 65 ±0.2% ±0.1% 24 9-36 95 1.4 87.5% 89% C80 P21 UEI30-150-Q48N-C 15 2 30 50 100 ±0.2% ±0.1% 48 18-75 50 0.7 87.5% 89.5% C80 P21 Output capacitors are 1 μF ceramic in parallel with 10 μF electrolytic. Input cap is 22 μF, low ESR.  Please refer to the part number structure for additional options and complete ordering part numbers. These I/O caps are necessary for our test equipment and may not be needed for your application.  All specifi cations are at nominal line voltage and full load, +25°C. unless otherwise noted. See detailed specifi cations. PART NUMBER STRUCTURE UEI30 - 050 - Q48 N H Lx - C RoHS-6 hazardous substance compliance Nominal Output Voltage (does not claim EU RoHS exemption 7b–lead in solder) In tenths of a volt Pin Length Option Input Voltage Range: Blank = Std. pin length 0.25˝ (6.3mm) Q12 = 9-36V L1 = 0.110˝ (2.79mm)* Q48 = 18-75V L2 = 0.145˝ (3.68mm)* *Special quantity order is required; Conformal Coating Option no sample quantities available. Blank = No coating, standard H = Coating added, optional (built to order; contact Murata Power Solutions for MOQ and lead times.)* On/Off Control Logic: P = Positive N = Negative Note: Some model number combinations Positive “P” logic is standard for Q12 models and optional special may not be available. Please contact order for Q48 models. Negative “N” logic is standard for Q48 models Murata Power Solutions. and optional special order for Q12 models. Special Customer Configuration part numbers: 1) UEI30-033-Q12PH-31328 (3.3Vout @ 30W, Positive Logic, Conformal Coating, Hipot Tested to 2,000Vrms) 2) UEI30-050-Q12PH-31329 (5Vout @ 30W, Positive Logic, Conformal Coating, Hipot Tested to 2,000Vrms) 3) UEI30-050-Q12PL1-C-NI (5Vout @ 30W, Positive Logic, 0.110” Pin Length, Control loop changes for large capacitive load) www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 2 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters FUNCTIONAL SPECIFICATIONS INPUT CHARACTERISTICS Remote On/Off Control Input Current Under- Refl ected Internal Reverse Start-up voltage (back) Input Inrush Output Model Family threshold Shut- Ripple Polarity Low Standby On/Off Filter 2 Tran- Short Positive Logic Negative Logic down Current Protection Line Mode Current Type sient Circuit 2 V V mA pk-pk A sec mA A mA A mA “P” model suffi x “N” model suffi x UEI30-033-Q12P-C 9.5 8.5 3.75 6 UEI30-033-Q48N-C 17.3 16.0* 1.89 6 1 1 OFF=Gnd pin or OFF=open pin UEI30-050-Q12P-C 9.5 8.0 3.75 6 None, 50 –0.7 to +1.2V or +10 to +15V UEI30-050-Q48N-C 17.0 16.2 1.88 6 install 30 0.05 L-C max. ON=open max. ON=Gnd external UEI30-120-Q12P-C 9.5 8.3 3.75 3 6 3.5 pin or +10 to pin or –0.7 to fuse UEI30-120-Q48N-C 17.0 16.5 1.85 4 +15V max. +1.2V max. UEI30-150-Q12P-C 9.5 8.3 80 3.72 1 6 1 UEI30-150-Q48N-C 16.9 16.3 50 1.83 4 *Specifi ed at half load OUTPUT CHARACTERISTICS VOUT Overvoltage Capacitive Loading Max. Accuracy protection Adjustment Temperature Low ESR <0.02Ω Max, Hiccup auto-start Model Family Range Coeffi cient 50% Load resistive load after fault removal % of VNOM % of VNOM % of VOUT /ºC μF V UEI30-033-Q12P-C 2 5.0 UEI30-033-Q48N-C 5.0 UEI30-050-Q12P-C 7.0 UEI30-050-Q48N-C 7.3 Magnetic ±10 ±0.02 2,000 No See ordering guide feedback UEI30-120-Q12P-C 1 15.5 UEI30-120-Q48N-C 14.1 UEI30-150-Q12P-C 18.5 UEI30-150-Q48N-C 24 Absolute Maximum Ratings ABSOLUTE MAXIMUM RATINGS Absolute maximums are stress ratings. Exposure of devices to Volts, max. continuous 0-36 VDC to rated specifi cations Q12 models greater than any of these conditions may adversely affect long-term Volts, transient, 100 mSec 50 VDC, no damage Input Voltage reliability. Proper operation under conditions other than those listed Volts, max. continuous 0-75 VDC to rated specifi cations Q48 models in the Performance/Functional Specifi cations Table is not implied nor Volts, transient, 100 mSec 100 VDC, no damage recommended. On/Off control, referred to –Vin -0.7 V. min to +15V max. Input Reverse Polarity Protection None, install external fuse Maximum Ratings Notes Output Overvoltage VOUT nom. +20% max. The transient specifi cations indicate that sample lots were success- Current-limited. Devices can fully tested for 100 mS at the transient stress voltage and were not withstand sustained short circuit damaged. As a practical matter in your application, it is often diffi cult Output Current without damage. The outputs are not intended to accept appreci- to determine how long an input overvoltage was applied. Therefore, able reverse current. do not exceed the continuous voltage rating. Device includes electronic over- Overtemperature Protection temperature shutdown protection under normal operation. Storage Temperature -55 to +125° C. Lead Temperature See soldering specifi cations www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 3 of 18 Recommended Fast-Blow Fuse Minimum loading OV protection method Ripple/Noise (20 MHz 8 bandwidth) Line/Load Regulation Effi ciency UEI30 Series 30W Isolated Wide-Range DC-DC Converters ISOLATION CHARACTERISTICS DYNAMIC CHARACTERISTICS Start-up Time Dynamic Load Input to Isolation Isolation Response Switching Output. Resistance VIN to VOUT Remote On/Off Insulation Safety Model Family Capacitance Model Family (50-75-50% Frequency regulated to VOUT Rating load step) Min Min (Max.) regulated (Max.) VDC MΩ pF μsec mSec mSec KHz UEI30-033-Q12P-C 2000 1000 UEI30-033-Q12P-C 120 to 2% 275 UEI30-033-Q48N-C 2250 1000 UEI30-033-Q48N-C 180 to 2% 280 UEI30-050-Q12P-C 2000 1000 UEI30-050-Q12P-C 80 to 2% 275 UEI30-050-Q48N-C 2250 1000 UEI30-050-Q48N-C 100 to 1% 275 10 Basic 50 50 UEI30-120-Q12P-C 2000 1500 UEI30-120-Q12P-C 200 to 1% 275 UEI30-120-Q48N-C 2250 1500 UEI30-120-Q48N-C 150 to 1% 275 UEI30-150-Q12P-C 2000 1500 UEI30-150-Q12P-C 150 to 1% 275 UEI30-150-Q48N-C 2250 2000 UEI30-150-Q48N-C 150 to 1% 275 MISCELLANEOUS CHARACTERISTICS Output Current Output Output Relative Storage Thermal Limit Inception Output Short Short Humidity, Short Output temperature protection/ Circuit Duration Operating Temperature Model Family Circuit non- Circuit Pre-biased 98% of VOUT, (output shorted Range range shutdown Current condensing Protection setup after warmup to ground) Method A A ºC ºC ºC UEI30-033-Q12P-C 11.5 0.3 max. UEI30-033-Q48N-C 11.2 0.3 max. UEI30-050-Q12P-C 7.9 Current 3.0 limiting, Monotonic –40 to +85ºC; UEI30-050-Q48N-C 7.4 0.3 max. To +85ºC/ hiccup Continuous (external with Derating –55 to 125ºC 115 85% RH UEI30-120-Q12P-C 4.1 1.5 auto VOUT < VSET) (see Notes) UEI30-120-Q48N-C 3.65 restart 0.75 UEI30-150-Q12P-C 3.0 0.5 UEI30-150-Q48N-C 3.25 0.1 max. Specifi cation Notes: capacitance can retard transient response or possibly cause instability. Low ESR ceramic capacitors (1) All models are tested and specifi ed with external 1 μF and 10 μF parallel output capacitors and a may degrade dynamic performance. Be sure to thoroughly test your system under full load with all 22 μF external input capacitor. All capacitors are low ESR types. These capacitors are necessary to components installed. accommodate our test equipment and may not be required to achieve specifi ed performance in your (9) All models are fully operational and meet published specifi cations, including “cold start” at –40°C. applications. All models are stable and regulate within spec under no-load conditions. (10) Regulation specifi cations describe the deviation as the line input voltage or output load current is All specifi cations are typical unless noted. General conditions for Specifi cations are +25 deg.C, varied from a nominal midpoint value to either extreme. Vin=nominal, Vout=nominal, full load. Adequate airfl ow must be supplied for extended testing under (11) The output overvoltage protection is automatic recovery. The overvoltage may occur either from power. internal failure or from an external forcing voltage as in a shared power system. (2) Input Back Ripple Current is tested and specifi ed over a 5 Hz to 20 MHz bandwidth. Input fi ltering (12) Output overvoltage and short circuit protection is non-latching. When the overvoltage fault is is Cin=33 μF, 100V, Cbus=220 μF, 100V, Lbus=12 μH. removed, the converter will immediately recover. After an output overcurrent or short circuit, “hiccup” (3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage. operation repeatedly attempts to restart the converter with a brief, full-current output. If the overcur- At higher temperatures and/or lower airfl ow, the DC/DC converter will tolerate brief full current rent condition still exists, the restart current will be removed and then tried again. This short current outputs if the total RMS current over time does not exceed the Derating curve. All Derating curves pulse prevents overheating and damaging the converter. Once the fault is removed, the converter are presented at sea level altitude. Be aware of reduced power dissipation with increasing density immediately resumes normal operation. altitude. (13) Do not exceed maximum power specifi cations when adjusting the output trim. (4) Refer to page 10 for MTBF values. (14) At zero output current, the output may contain low frequency components which exceed the (5) The On/Off Control is normally selected by a switch or an open collector or open drain transistor. ripple specifi cation. The output may be operated indefi nitely with no load. But it may also be driven with external logic or by applying appropriate external voltages which are (15) If reverse polarity is accidentally applied to the input, to ensure reverse input protection with full referenced to Input Common and do not exceed the On/Off voltage specifi cations. output load, always connect an external input fuse in series with the +Vin input. Use approximately (6) Output current limiting begins when the output voltage degrades approximately 2% from the twice the full input current rating with nominal input voltage. selected setting. CAUTION: This product is not internally fused. To comply with safety agency certifi cations and to (7) The outputs are not intended to sink appreciable reverse current. avoid injury to personnel or equipment, the user must connect an external fast-blow fuse to the input (8) Output noise may be further reduced by adding an external fi lter. Low voltage logic circuits may terminals. See fuse information. have a small voltage margin between logic ZERO and logic ONE, requiring noise suppression. Use only as much output fi ltering as needed to achieve your noise requirements. Excessive output www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 4 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters PERFORMANCE DATA UEI30-033-Q12 Effi ciency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (VIN = 12V, airfl ow is from input to output) 90 9 8.8 Natural convection 85 8.6 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 8.4 1.5 m/s (300 LFM) 80 2.0 m/s (400 LFM) 8.2 Vin = 36 V 8 Vin = 24 V 75 7.8 Vin = 12 V 7.6 Vin = 9 V 70 7.4 7.2 65 7 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 60 Ambient Temperature (ºC) 0 12 3 45 6 78 9 Load Current (Amps) UEI30-033-Q48 Effi ciency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (VIN = 24V, airfl ow is from input to output) 100 9.1 90 9 Natural convection 80 8.9 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 70 8.8 Vin = 75 V Vin = 48 V 60 8.7 Vin = 24 V 50 8.6 Vin = 18 V 40 8.5 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 30 Ambient Temperature (ºC) 20 0 12 34 5 6 78 9 Load Current (Amps) UEI30-033-Q48 Maximum Current Temperature Derating @Sea Level (VIN = 48V, airfl ow is from input to output) 9.1 9 Natural convection 8.9 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 8.8 8.7 8.6 8.5 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Ambient Temperature (ºC) www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 5 of 18 Efficiency (%) Efficiency (%) Output Current (Amps) Output Current (Amps) Output Current (Amps) UEI30 Series 30W Isolated Wide-Range DC-DC Converters PERFORMANCE DATA UEI30-050-Q12 Effi ciency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (VIN = 12 or 24V, airfl ow is from input to output) 100 6.10 90 6.00 Natural convection 80 5.90 70 5.80 Vin = 36 V Vin = 24 V 60 5.70 Vin = 12 V 50 5.60 Vin = 10 V 5.50 40 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Ambient Temperature (ºC) 30 20 Load Current (Amps) UEI30-050-Q48 Effi ciency vs. Line Voltage and Load Current @ 25°C Maximum Current Temperature Derating @Sea Level (VIN = 18V, transverse airfl ow) 100 90 6.1 80 6.0 70 Natural convection Vin = 75 V 5.9 0.5 m/s (100 LFM) Vin = 48 V 1.0 m/s (200 LFM) 60 5.8 1.5 m/s (300 LFM) Vin = 24 V 50 Vin = 18 V 5.7 5.6 40 5.5 30 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Ambient Temperature (ºC) 20 Load Current (Amps) UEI30-050-Q48 Maximum Current Temperature Derating @Sea Level Maximum Current Temperature Derating @Sea Level (VIN = 24V, transverse airfl ow) (VIN = 48V, transverse airfl ow) 6.1 6.1 6.0 6.0 Natural convection 5.9 5.9 Natural convection 5.8 5.8 0.5 m/s (100 LFM) 5.7 5.7 5.6 5.6 5.5 5.5 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Ambient Temperature (ºC) Ambient Temperature (ºC) www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 6 of 18 0 1.00 2.00 3.00 4.00 5.00 6.00 0 1.00 2.00 3.00 4.00 5.00 6.00 Output Current (Amps) Efficiency (%) Efficiency (%) Output Current (Amps) Output Current (Amps) Output Current (Amps) UEI30 Series 30W Isolated Wide-Range DC-DC Converters PERFORMANCE DATA UEI30-120-Q12 Effi ciency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs. Load Current @ 25°C 4.5 90 Vin = 36 V 4.0 Vin = 24 V 88 Vin = 12 V 86 3.5 Vin = 9 V 84 3.0 82 Vin = 36 V 80 2.5 Vin = 24 V 78 Vin = 12 V 2.0 Vin = 9 V 76 74 1.5 72 1.0 70 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5 68 Load Current (Amps) 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5 Load Current (Amps) UEI30-120-Q12 Maximum Current Temperature Derating @Sea Level Maximum Current Temperature Derating @Sea Level (VIN = 9-24V, transverse airfl ow) (VIN = 36V, transverse airfl ow) 2.55 2.55 2.50 2.50 0.5 m/s (100 LFM) 100 LFM 1.0 m/s (200 LFM) 2.45 2.45 2.40 2.35 2.40 2.30 2.35 2.25 2.20 2.30 20 25 30 35 40 45 50 55 60 65 70 75 80 85 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (ºC) Ambient Temperature (ºC) www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 7 of 18 Output Current (Amps) Efficiency (%) Output Current (Amps) Power Dissipation (Watts) UEI30 Series 30W Isolated Wide-Range DC-DC Converters PERFORMANCE DATA UEI30-120-Q48 Effi ciency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs. Load Current @ 25°C Vin = 75V 90 4.5 Vin = 48V 88 Vin = 24V 4.0 86 Vin = 18V 3.5 84 82 3.0 Vin = 75 V 80 2.5 Vin = 48 V 78 Vin = 24 V 2.0 76 Vin = 18 V 74 1.5 72 1.0 70 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5 68 Load Current (Amps) 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.1 2.3 2.5 Load Current (Amps) UEI30-120-Q48 Maximum Current Temperature Derating @Sea Level Maximum Current Temperature Derating @Sea Level (VIN = 18-48V, transverse airfl ow) (VIN = 75V, transverse airfl ow) 3.00 2.60 2.55 2.75 2.50 2.50 100 LFM 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 2.45 2.25 2.40 2.00 2.35 1.75 2.30 1.50 2.25 1.25 2.20 1.00 20 25 30 35 40 45 50 55 60 65 70 75 80 85 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (ºC) Ambient Temperature (ºC) www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 8 of 18 Output Current (Amps) Efficiency (%) Output Current (Amps) Power Dissipation (Watts) UEI30 Series 30W Isolated Wide-Range DC-DC Converters PERFORMANCE DATA UEI30-150-Q12 Effi ciency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs. Load Current @ 25°C 4.5 90 4.0 88 86 3.5 84 3.0 82 80 Vin = 36 V 2.5 Vin = 24 V 78 Vin = 12 V 2.0 Vin = 36 V 76 Vin = 9 V Vin = 24 V 74 1.5 Vin = 12 V 72 Vin = 9 V 1.0 70 0.4 0.5 0.7 0.9 1.0 1.2 1.4 1.5 1.7 1.8 2.0 68 Load Current (Amps) 0.4 0.5 0.7 0.9 1.0 1.2 1.4 1.5 1.7 1.8 2.0 Load Current (Amps) UEI30-150-Q12 Maximum Current Temperature Derating @Sea Level Maximum Current Temperature Derating @Sea Level (VIN = 9-24V, transverse airfl ow) (VIN = 36V, transverse airfl ow) 2.05 2.05 2.00 2.00 100 LFM 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 1.95 1.95 1.90 1.90 1.85 1.85 1.80 20 25 30 35 40 45 50 55 60 65 70 75 80 85 1.80 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (ºC) Ambient Temperature (ºC) UEI30-150-Q12 Maximum Current Temperature Derating @Sea Level (Natural convection) 2.5 2 1.5 Vin = 12 V Vin = 24 V 1 0.5 0 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (ºC) www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 9 of 18 Output Current (Amps) Efficiency (%) Output Current (Amps) Output Current (Amps) Power Dissipation (Watts) UEI30 Series 30W Isolated Wide-Range DC-DC Converters PERFORMANCE DATA UEI30-150-Q48 Effi ciency vs. Line Voltage and Load Current @ 25°C Power Dissipation vs. Load Current @ 25°C 92 5.0 90 4.5 88 4.0 Vin = 75V 86 Vin = 48V 3.5 Vin = 24V 84 3.0 Vin = 18V 82 Vin = 75 V 2.5 80 Vin = 48 V 2.0 78 Vin = 24 V Vin = 18 V 1.5 76 1.0 74 0.7 0.8 1.0 1.1 1.2 1.3 1.5 1.6 1.7 1.9 2.0 72 Load Current (Amps) 0.7 0.8 1.0 1.1 1.2 1.3 1.5 1.6 1.7 1.9 2.0 Load Current (Amps) UEI30-150-Q48 Maximum Current Temperature Derating @Sea Level Maximum Current Temperature Derating @Sea Level (VIN = 18-48V, transverse airfl ow) (VIN = 75V, transverse airfl ow) 2.2 2.2 2.0 2.0 Natural Convection 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 1.8 1.8 1.6 1.6 1.4 1.4 1.2 1.2 1.0 1.0 20 25 30 35 40 45 50 55 60 65 70 75 80 85 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (ºC) Ambient Temperature (ºC) www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 10 of 18 Output Current (Amps) Efficiency (%) Output Current (Amps) Power Dissipation (Watts) UEI30 Series 30W Isolated Wide-Range DC-DC Converters MECHANICAL SPECIFICATIONS TOP VIEW 1.92 (48.8) PIN #1 Dimensions are in inches (mm shown for ref. only). Third Angle Projection 0.92 (23.4) Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ SIDE VIEW Components are shown for reference only. 0.35 (8.9) 0.25 (6.4) MOUNTING PLANE 0.040 0.002 PIN WITH 0.071 0.002 SHOULDER BOTTOM VIEW 6X AT PINS 1-6 1.800 #6 (45.72) #3 C L 0.900 REF END VIEW (22.86) #5 #2 0.400 .0300 (7.62) (10.16) C L 0.100 (2.54) 0.300 (7.62) .0400 (10.16) C L #1 #4 UEI30 Open Frame 30W Package C80 INPUT/OUTPUT CONNECTIONS PHYSICAL CHARACTERISTICS Pin Function P21 Pin Function P21 Copper alloy with gold plate over nickel Pin material underplate 1 + Vin 4 + Vout 2 - Vin 5 - Vout Pin diameter 0.04" (1.016mm) 3 Remote On/Off* 6 Trim Pin Finish Gold plate * The Remote On/Off can be provided with either positive (P suffi x) or negative Weight 0.53 oz (15g) (N suffi x) logic. Electromagnetic interference EN55022/CISPR22 (requires external fi lter) Flammability Rating UL 94V-0 Designed to meet IEC/EN/UL/cUL 60950-1, Safety CSA-C22.2 No. 60950-1 www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 11 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters SHIPPING TRAYS AND BOXES Anti-static foam Label Label For 1–42 pc quantity For 43–84 pc quantity SHIPPING TRAY UEI30 modules are supplied in a 21-piece (3-by-7) shipping tray. The tray is an anti-static closed-cell polyethylene foam. Dimensions are shown below. 9.920 +0.000 (252) -0.062 0.910 (23.1) TYP 0.455 (11.6) TYP 0.735 (18.7) 9.920 (252) +0.000 -0.062 0.625 (15.9) TYP 2.400 (61) TYP Dimensions in inches (mm) 0.25 R TYP 1.300 (33.0) TYP 0.25 CHAMFER TYP (4-PL) 7.800 1.06 (198.1) (26.9) www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 12 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters Sometimes only a small ceramic capacitor is suffi cient. Since it is diffi cult to TECHNICAL NOTES totally characterize all applications, some experimentation may be needed. Input Fusing Note that external input capacitors must accept high speed switching currents. Certain applications and/or safety agencies may require fuses at the inputs of Because of the switching nature of DC/DC converters, the input of these power conversion components. Fuses should also be used when there is the converters must be driven from a source with both low AC impedance and possibility of sustained input voltage reversal which is not current-limited. For adequate DC input regulation. Performance will degrade with increasing input greatest safety, we recommend a fast blow fuse installed in the ungrounded inductance. Excessive input inductance may inhibit operation. The DC input input supply line. regulation specifi es that the input voltage, once operating, must never degrade The installer must observe all relevant safety standards and regulations. For below the Shut-Down Threshold under all load conditions. Be sure to use safety agency approvals, install the converter in compliance with the end-user adequate trace sizes and mount components close to the converter. safety standard. I/O Filtering, Input Ripple Current and Output Noise Input Reverse-Polarity Protection All models in this converter series are tested and specifi ed for input refl ected If the input voltage polarity is reversed, an internal diode will become forward ripple current and output noise using designated external input/output compo- biased and likely draw excessive current from the power source. If this source nents, circuits and layout as shown in the fi gures below. External input capaci- is not current-limited or the circuit appropriately fused, it could cause perma- tors (CIN in the fi gure) serve primarily as energy storage elements, minimizing nent damage to the converter. line voltage variations caused by transient IR drops in the input conductors. Users should select input capacitors for bulk capacitance (at appropriate Input Under-Voltage Shutdown and Start-Up Threshold frequencies), low ESR and high RMS ripple current ratings. In the fi gure below, Under normal start-up conditions, converters will not begin to regulate properly the CBUS and LBUS components simulate a typical DC voltage bus. Your specifi c until the rising input voltage exceeds and remains at the Start-Up Threshold system confi guration may require additional considerations. Please note that the Voltage (see Specifi cations). Once operating, converters will not turn off until values of CIN, LBUS and CBUS will vary according to the specifi c converter model. the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent restart will not occur until the input voltage rises again above the Start-Up Threshold. This built-in hysteresis prevents any unstable on/off operation at a TO CURRENT OSCILLOSCOPE single input voltage. PROBE 1 +VIN Users should be aware however of input sources near the Under-Voltage LBUS + Shutdown whose voltage decays as input current is consumed (such as capaci- – tor inputs), the converter shuts off and then restarts as the external capacitor VIN CBUS CIN + recharges. Such situations could oscillate. To prevent this, make sure the operat- – ing input voltage is well above the UV Shutdown voltage AT ALL TIMES. 2 −VIN Start-Up Delay CIN = 33μF, ESR < 700mΩ @ 100kHz Assuming that the output current is set at the rated maximum, the Vin to Vout Start- CBUS = 220μF, ESR < 100mΩ @ 100kHz LBUS = 12μH Up Delay (see Specifi cations) is the time interval between the point when the rising input voltage crosses the Start-Up Threshold and the fully loaded regulated output Figure 2. Measuring Input Ripple Current voltage enters and remains within its specifi ed regulation band. Actual measured times will vary with input source impedance, external input capacitance, input volt- age slew rate and fi nal value of the input voltage as it appears at the converter. These converters include a soft start circuit to moderate the duty cycle of the PWM controller at power up, thereby limiting the input inrush current. +VOUT The On/Off Remote Control interval from inception to VOUT regulated RLOAD SCOPE assumes that the converter already has its input voltage stabilized above the C1 C2 Start-Up Threshold before the On command. The interval is measured from the On command until the output enters and remains within its specifi ed accuracy −VOUT band. The specifi cation assumes that the output is fully loaded at maximum rated current. C1 = 1μF Input Source Impedance C2 = 10μF LOW ES These converters will operate to specifi cations without external components, LOAD 2-3 INCHES (51-76mm) FROM MODULE assuming that the source voltage has very low impedance and reason- Figure 3. Measuring Output Ripple and Noise (PARD) able input voltage regulation. Since real-world voltage sources have fi nite impedance, performance is improved by adding external fi lter components. www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 13 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters In critical applications, output ripple and noise (also referred to as periodic an unplanned Over Temperature shut down. Also, these graphs are all collected and random deviations or PARD) may be reduced by adding fi lter elements near Sea Level altitude. Be sure to reduce the derating for higher altitude. such as multiple external capacitors. Be sure to calculate component tempera- Output Overvoltage Protection (OVP) ture rise from refl ected AC current dissipated inside capacitor ESR. This converter monitors its output voltage for an over-voltage condition using Floating Outputs an on-board electronic comparator. The signal is optically coupled to the pri- Since these are isolated DC/DC converters, their outputs are “fl oating” with mary side PWM controller. If the output exceeds OVP limits, the sensing circuit respect to their input. The essential feature of such isolation is ideal ZERO will power down the unit, and the output voltage will decrease. After a time-out CURRENT FLOW between input and output. Real-world converters however do period, the PWM will automatically attempt to restart, causing the output volt- exhibit tiny leakage currents between input and output (see Specifi cations). age to ramp up to its rated value. It is not necessary to power down and reset These leakages consist of both an AC stray capacitance coupling component the converter for the this automatic OVP-recovery restart. and a DC leakage resistance. When using the isolation feature, do not allow If the fault condition persists and the output voltage climbs to excessive the isolation voltage to exceed specifi cations. Otherwise the converter may levels, the OVP circuitry will initiate another shutdown cycle. This on/off cycling be damaged. Designers will normally use the negative output (-Output) as is referred to as “hiccup” mode. the ground return of the load circuit. You can however use the positive output (+Output) as the ground return to effectively reverse the output polarity. Output Fusing The converter is extensively protected against current, voltage and temperature Minimum Output Loading Requirements extremes. However, your application circuit may need additional protection. In the These converters employ a synchronous rectifi er design topology. All models extremely unlikely event of output circuit failure, excessive voltage could be applied regulate within specifi cation and are stable under no load to full load conditions. to your circuit. Consider using an appropriate external protection. Operation under no load might however slightly increase output ripple and noise. Output Current Limiting Thermal Shutdown As soon as the output current increases to approximately its overcurrent limit, To protect against thermal over-stress, these converters include thermal shut- the DC/DC converter will enter a current-limiting mode. The output voltage will down circuitry. If environmental conditions cause the temperature of the DC/ decrease proportionally with increases in output current, thereby maintaining a DC’s to rise above the Operating Temperature Range up to the shutdown tem- somewhat constant power output. This is commonly referred to as power limiting. perature, an on-board electronic temperature sensor will power down the unit. Current limiting inception is defi ned as the point at which full power falls When the temperature decreases below the turn-on threshold, the converter will automatically restart. There is a small amount of hysteresis to prevent below the rated tolerance. See the Performance/Functional Specifi cations. Note particularly that the output current may briefl y rise above its rated value. This rapid on/off cycling. CAUTION: If you operate too close to the thermal limits, the converter may shut down suddenly without warning. Be sure to thoroughly test enhances reliability and continued operation of your application. If the output current is too high, the converter will enter the short circuit condition. your application to avoid unplanned thermal shutdown. Temperature Derating Curves Output Short Circuit Condition When a converter is in current-limit mode, the output voltage will drop as The graphs in this data sheet illustrate typical operation under a variety of condi- tions. The Derating curves show the maximum continuous ambient air temperature the output current demand increases. If the output voltage drops too low, the magnetically coupled voltage used to develop PWM bias voltage will also drop, and decreasing maximum output current which is acceptable under increasing forced airfl ow measured in Linear Feet per Minute (“LFM”). Note that these are thereby shutting down the PWM controller. Following a time-out period, the PWM will restart, causing the output voltage to begin rising to its appropriate AVERAGE measurements. The converter will accept brief increases in temperature and/or current or reduced airfl ow as long as the average is not exceeded. value. If the short-circuit condition persists, another shutdown cycle will initi- ate. This on/off cycling is called “hiccup mode.” The hiccup cycling reduces the Note that the temperatures are of the ambient airfl ow, not the converter average output current, thereby preventing excessive internal temperatures. itself which is obviously running at higher temperature than the outside air. Also note that “natural convection” is defi ned as very fl ow rates which are not Trimming the Output Voltage using fan-forced airfl ow. Depending on the application, “natural convection” is The Trim input to the converter allows the user to adjust the output voltage over usually about 30-65 LFM but is not equal to still air (0 LFM). the rated trim range (please refer to the Specifi cations). In the trim equations and circuit diagrams that follow, trim adjustments use either a trimpot or a single Murata Power Solutions makes Characterization measurements in a closed fi xed resistor connected between the Trim input and either the +Vout or –Vout cycle wind tunnel with calibrated airfl ow. We use both thermocouples and an terminals. (On some converters, an external user-supplied precision DC voltage infrared camera system to observe thermal performance. As a practical matter, may also be used for trimming). Trimming resistors should have a low tempera- it is quite diffi cult to insert an anemometer to precisely measure airfl ow in ture coeffi cient (±100 ppm/deg.C or less) and be mounted close to the converter. most applications. Sometimes it is possible to estimate the effective airfl ow if Keep leads short. If the trim function is not used, leave the trim unconnected. you thoroughly understand the enclosure geometry, entry/exit orifi ce areas and With no trim, the converter will exhibit its specifi ed output voltage accuracy. the fan fl owrate specifi cations. There are two CAUTIONs to observe for the Trim input: CAUTION: If you exceed these Derating guidelines, the converter may have www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 14 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters CAUTION: To avoid unplanned power down cycles, do not exceed EITHER the Remote On/Off Control maximum output voltage OR the maximum output power when setting the trim. On the input side, a remote On/Off Control can be specifi ed with either positive Be particularly careful with a trimpot. If the output voltage is excessive, the OVP or negative logic as follows: circuit may inadvertantly shut down the converter. If the maximum power is Positive: Models equipped with Positive Logic are enabled when the On/Off exceeded, the converter may enter current limiting. If the power is exceeded for pin is left open or is pulled high to +VIN with respect to –VIN. An internal bias an extended period, the converter may overheat and encounter overtempera- current causes the open pin to rise to +VIN. Some models will also turn on at ture shut down. lower intermediate voltages (see Specifi cations). Positive-logic devices are CAUTION: Be careful of external electrical noise. The Trim input is a senstive disabled when the On/Off is grounded or brought to within a low voltage (see input to the converter’s feedback control loop. Excessive electrical noise may Specifi cations) with respect to –VIN. cause instability or oscillation. Keep external connections short to the Trim Negative: Models with negative logic are on (enabled) when the On/Off is input. Use shielding if needed. grounded or brought to within a low voltage (see Specifi cations) with respect to –VIN. The device is off (disabled) when the On/Off is left open or is pulled high +VOUT to +15VDC Max. with respect to –VIN. −VIN Dynamic control of the On/Off function should be able to sink the speci- fi ed signal current when brought low and withstand appropriate voltage when brought high. Be aware too that there is a fi nite time in milliseconds 5-22 (see Specifi cations) between the time of On/Off Control activation and stable, 7 ON/OFF LOAD TRIM TURNS CONTROL regulated output. This time will vary slightly with output load type and current and input conditions. +VIN +VOUT −VOUT +VIN Figure 4. Trim adjustments using a trimpot ON/OFF TRIM LOAD Trim Equations CONTROL RTRIM DOWN Trim Up Trim Down between Trim and +Vout> −VIN −VOUT UEI30-033-Q12/-Q48 12775 5110 (Vo - 2.5) Figure 5. Trim adjustments to decrease Output Voltage using a Fixed Resistor – 2050 – 2050 RT (Ω) = RT (Ω) = UP DOWN VO – 3.3 3.3 – VO UEI30-050-Q12/-Q48 12775 5110 (Vo - 2.5) +VOUT +VIN – 2050 – 2050 RT (Ω) = RT (Ω) = UP DOWN VO – 5 5 – VO UEI30-120-Q12/-Q48 25000 10000 (Vo-2.5) –5110 – 5110 RT (Ω) = ON/OFF RT (Ω) = UP DOWN TRIM LOAD 12 – VO VO – 12 CONTROL R TRIM UP UEI30-150-Q12/-Q48 25000 10000 (Vo-2.5) – 5110 RT (Ω) = –5110 RT (Ω) = UP DOWN 15 – VO VO – 15 −VIN −VOUT Figure 6. Trim adjustments to increase Output Voltage using a Fixed Resistor Where Vo = Desired output voltage. Adjustment accuracy is subject to resis- tor tolerances and factory-adjusted output accuracy. Mount trim resistor close to converter. Use short leads. www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 15 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters There are two CAUTIONs for the On/Off Control: Emissions Performance Murata Power Solutions measures its products for radio frequency emissions CAUTION: While it is possible to control the On/Off with external logic if you against the EN 55022 and CISPR 22 standards. Passive resistance loads are carefully observe the voltage levels, the preferred circuit is either an open employed and the output is set to the maximum voltage. If you set up your drain/open collector transistor or a relay (which can thereupon be controlled by own emissions testing, make sure the output load is rated at continuous power logic). The On/Off prefers to be set at approx. +15V (open pin) for the ON state, while doing the tests. assuming positive logic. The recommended external input and output capacitors (if required) are CAUTION: Do not apply voltages to the On/Off pin when there is no input included. Please refer to the fundamental switching frequency. All of this power voltage. Otherwise the converter may be permanently damaged. information is listed in the Product Specifi cations. An external discrete fi lter is installed and the circuit diagram is shown below. Resistive MODEL# UEI30-050-Q48N-C Load +VCC 30W 48 Vdc in, 5 Vout, 6 Amps UUT V+ Resistive Vin + Vout + Load 3 C5 C1 C2 C3 C4 C7 C8 inside a L1 metal C6 container ON/OFF V- CONTROL Vin - Vout - 1 -VIN Figure 8. Conducted Emissions Test Circuit [1] Conducted Emissions Parts List Figure 7. Driving the On/Off Control Pin (suggested circuit) Reference Description L1 500μH, 4.1A C8 Electrolytic Capacitor 100μfd, 100V C1, C2, C3 C4, C5, C6, C7 3.3μfd, 50V [2] Conducted Emissions Test Equipment Used  Rohde & Schwarz EMI Test Receiver (9KHz – 1000MHz) ESPC  Rohde & Schwarz Software ESPC-1 Ver. 2.20  OHMITE 25W – 1 Ohm resistor combinations  DC Source Programmable DC Power Supply Model 62012P-100-50 [3] Conducted Emissions Test Results dBμV CONAV 80 70 60 50 40 30 20 10 0 -10 -20 0.15 1.0 10.0 30.0 MHz Graph 1. Conducted emissions performance with fi lter, Negative Line, CISPR 22, Class B, full load, for UEI30-033-Q48N-C www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 16 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters dBμV CONAV dBμV CONAV 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 -10 -10 -20 -20 0.15 1.0 10.0 30.0 0.15 1.0 10.0 30.0 MHz MHz Graph 2. Conducted emissions performance with fi lter, Negative Line, CISPR 22, Graph 5. Conducted emissions performance with fi lter, Negative Line, CISPR 22, Class B, 5.43A @ 48Vin, for UEI30-050-Q48N-C Class B, full load, for UEI30-150-Q12N-C dBμV dBμV CONAV CONAV 80 90 70 80 60 70 50 60 40 50 30 40 20 30 10 20 0 10 -10 0 -20 -10 0.15 1.0 10.0 30.0 0.15 1.0 10.0 30.0 MHz MHz Graph 3. Conducted emissions performance with fi lter, Negative Line, CISPR 22, Graph 6. Conducted emissions performance with fi lter, Negative Line, CISPR 22, Class B, full load, for UEI30-120-Q12N-C Class B, full load, for UEI30-150-Q48N-C dBμV CONAV 80 70 [4] Layout Recommendations 60 Most applications can use the fi ltering which is already installed inside the 50 converter or with the addition of the recommended external capacitors. For 40 30 greater emissions suppression, consider additional fi lter components and/or 20 shielding. Emissions performance will depend on the user’s PC board layout, 10 the chassis shielding environment and choice of external components. 0 -10 Since many factors affect both the amplitude and spectra of emissions, we -20 recommend using an engineer who is experienced at emissions suppression. 0.15 1.0 10.0 30.0 MHz Graph 4. Conducted emissions performance with fi lter, Negative Line, CISPR 22, Class B, full load, for UEI30-120-Q48N-C www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 17 of 18 UEI30 Series 30W Isolated Wide-Range DC-DC Converters Mean Time Before Failure (MTBF) Table These fi gures use a standard MTBF probability calculation as an indication of component parts stress and life derating. The calculaton is based on separate MTBF values for all internal parts in addition to stated environmental conditions. Two MTBF values are presented. The Telcordia method is widely used in industry, partic- ularly telecom. The United States MIL-HDBK method is for military and industrial applications. Please refer to a qualifi ed reliability engineer for more background. Model Number MTBF (Hours) Method [1,2] UEI30-033-Q12N-C 2,676,902 Telcordia UEI30-033-Q12N-C 2,123,124 MIL-HDBK UEI30-033-Q12P-C 2,733,781 Telcordia UEI30-033-Q12P-C 2,142,206 MIL-HDBK Notes: UEI30-033-Q48N-C 3,416,592 Telcordia [1] Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method UEI30-033-Q48N-C 3,172,548 MIL-HDBK 1, Case 3, ISSUE 2, ground fi xed controlled conditions, Tambient=+25°C, full output load, natural air convection. UEI30-033-Q48P-C 3,427,027 Telcordia [2] Mean Time Before Failure is calculated using MIL-HDBK-217FN2, GB ground benign, Tambient=+25°C, full output load, natural air convection. UEI30-033-Q48P-C 3,193,652 MIL-HDBK UEI30-050-Q12N-C 2,531,509 Telcordia UEI30-050-Q12N-C 2,207,508 MIL-HDBK UEI30-050-Q12P-C 2,554,127 Telcordia UEI30-050-Q12P-C 2,229,031 MIL-HDBK UEI30-120-Q48N-C 3,072,461 Telcordia UEI30-120-Q48N-C 2,510,927 MIL-HDBK UEI30-120-Q48P-C 2,900,319 Telcordia UEI30-120-Q48P-C 2,495,846 MIL-HDBK UEI30-150-Q48N-C 2,833,366 Telcordia UEI30-150-Q48N-C 2,408,836 MIL-HDBK UEI30-150-Q48P-C 2,776,615 Telcordia UEI30-150-Q48P-C 2,421,938 MIL-HDBK Soldering Guidelines Murata Power Solutions recommends the specifi cations below when installing these converters. These specifi cations vary depending on the solder type. Exceeding these specifi ca- tions may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers. Wave Solder Operations for through-hole mounted products (THMT) For Sn/Ag/Cu based solders: For Sn/Pb based solders: Maximum Preheat Temperature 115° C. Maximum Preheat Temperature 105° C. Maximum Pot Temperature 270° C. Maximum Pot Temperature 250° C. Maximum Solder Dwell Time 7 seconds Maximum Solder Dwell Time 6 seconds This product is subject to the following operating requirements Murata Power Solutions, Inc. and the Life and Safety Critical Application Sales Policy: 129 Flanders Road, Westborough, MA 01581 U.S.A. Refer to: http://www.murata-ps.com/requirements/ ISO 9001 and 14001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2018 Murata Power Solutions, Inc. www.murata-ps.com/support MDC_UEI Series 30W.B03 Page 18 of 18

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the UEI30-033-Q48N-C?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

DC/DC 8-36VIN/3.3VOUT .5A SIP 7803SR-C

product

DC/DC 8-36VIN/3.3VOUT .5A HSIP 7803SRH-C

product

DC/DC 8-36VIN/5VOUT .5A SIP 7805SR-C

product

DC/DC 8-36VIN/5VOUT .5A HSIP 7805SRH-C

product

4.8 W, 15 -36 VDC VIN, SINGLE OUTPUT, 12 VDC@0.4 A DC-DC CONVERTER 7812SR-C

product

4.8 W, 15 -36 VDC VIN, SINGLE OUTPUT, 12 VDC@0.4 A DC-DC CONVERTER 7812SRH-C