MURATA POWER SOLUTIONS UWQ-12/17-Q48N-C
Specifications
Manufacturer
Murata Power Solutions
Manufacturers Part #
UWQ-12/17-Q48N-C
Series
UWQ-12/17-Q48T-C
Factory Pack Quantity
15
Cooling Method
Convection
Dimensions
2.30 x 1.45 x 0.46"
Efficiency
92%
Input Voltage Nominal
48 VDC
Isolation
2250 VDC
Mechanical Style
Isolated
Mounting
Through Hole
Number of Outputs
1
Operating Temperature
- 40 to + 85°C
Output Amps 1
17 A
Output Voltage V1 Nominal
12 VDC
Power
204 W
Subcategory
DC-DC Converter
Datasheet
Extracted Text
UWQ-12/17-Q48 Series www.murata-ps.com Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PRODUCT OVERVIEW The UWQ series offers high output current (up to For systems needing controlled startup/shutdown, 17 Amps) in an industry standard “quarter brick” an external remote On/Off control may use either package requiring no heat sink for most applica- positive or negative logic. tions. The UWQ series delivers fi xed DC output A wealth of self-protection features include voltages up to 204 Watts (12V @17A) for printed input undervoltage lockout and overtemperature circuit board mounting. Wide range inputs of 18 shutdown using an on-board temperature sensor; T Typical unit ypical unit to 75 Volts DC (48 Volts nominal) are ideal for overcurrent protection using the “hiccup” auto- datacom and telecom systems. restart technique, provides indefi nite short-circuit Advanced automated surface mount assembly protection, along with output OVP. The synchronous FEATURES and planar magnetics deliver galvanic isolation rectifi er topology offers high effi ciency for minimal rated at 2250 Vdc for basic insulation. To power heat generation and “no heat sink” operation. The Fixed DC outputs, 12V @17A digital systems, the outputs offer fast settling to UWQ series is certifi ed to safety standards UL/ Industry standard quarter brick 2.3” x 1.45” x current steps and tolerance of higher capacitive EN/IEC/CSA 60950-1, 2nd edition. It meets RFI/ 0.46” open frame package loads. Excellent ripple and noise specifi cations as- EMI conducted/radiated emission compliance to Wide range 18 to 75 Vdc input voltages with sure compatibility to CPU’s, ASIC’s, programmable EN55022, CISPR22 with an external fi lter. 2250 Volt Basic isolation logic and FPGA’s. No minimum load is required. Remote ON/Off enable control DOSA-compatible pinouts and form factor High effi ciency synchronous rectifi er topology Stable no-load operation APPLICATIONS Monotonic startup into pre-bias output condition Embedded systems, datacom and telecom Instrumentation systems, R&D platforms, auto- Certifi ed to UL/EN 60950-1, CSA-C22.2 No. installations, wireless base stations mated test fi xtures 60950-1, 2nd edition safety approvals Disk farms, data centers and cellular repeater sites Data concentrators, voice forwarding and Extensive self-protection, OVP, input undervolt- speech processing systems age, current limiting and thermal shutdown Remote sensor systems, dedicated controllers F1 +Vin (1) +Vout (8) Barrier External On/Off DC Control Controller Power (2) and Power Source Open = On Reference and Error Amplifier logic) -Vin (3) -Vout (4) Figure 1. Connection Diagram Typical topology is shown. Murata Power Solutions recommends an external fuse. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 1 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE ➀ Output Input R/N (mV IOUT IIN full pk-pk) Regulation (Max.) ➁ Effi ciency Dimensions VOUT (Amps, Power VIN Nom. Range IIN no load (Volts) max.) (Watts) Typ. Max. Line Load (Volts) (Volts) load (mA) (Amps) Min. Typ. (inches) (mm) Root Model ➀ U UWQ-12/17-Q48 WQ-12/17-Q48 ➂ 12 17 204 100 120 ±1% ±1.5% 48 18-75 80 4.62 90% 92% 2.30x1.45x0.46 max. 2.30x1.45x0.46 max. 58.4x36.8x11.7 58.4x36.8x11.7 ➀ Please refer to the part number structure for additional ordering information and options. detailed specifi cations. Output capacitors are 1 μF || 10 μF with a 22μF input capacitor. These caps are ➁ All specifi cations are typical at nominal line voltage and full load, +25°C unless otherwise noted. See necessary for our test equipment and may not be needed for your application. PART NUMBER STRUCTURE UWQ - 12 / 17 Q48 N B S Lx - C - RoHS Hazardous Materials compliance Family C = RoHS-6 (does not claim EU RoHS exemption 7b–lead in solder), standard Series: Wide Input Quarter Brick Pin length option Blank = Standard pin length 0.180 in. (4.6 mm) Nominal Output Voltage L1 = 0.110 in. (2.79 mm)* L2 = 0.145 in. (3.68 mm)* Maximum Rated Output: *Minimum order quantity is required. Current in Amps Samples available with standard pin Load Share Option length only. Blank = No share Input Voltage Range: S = Load share Q48 = 18-75 Volts (48V nominal) Note: Some model number combinations may On/Off Control Logic Baseplate (optional) not be available. See website or contact N = Negative logic Blank = No baseplate, standard your local Murata sales representative. P = Positive logic B = Baseplate installed, optional UWQ-12/17-Q48NBL1-C Complete Model Number Example: Negative On/Off logic, baseplate installed, 0.110˝ pin length, RoHS-6 compliance www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 2 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters FUNCTIONAL SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS Conditions ➀ Minimum Typical/Nominal Maximum Units Input Voltage, Continuous Full power operation 18 48 80 Vdc Operating or non-operating, Input Voltage, Transient 100 Vdc 100 mS max. duration Isolation Voltage Input to output 2250 Vdc Input Reverse Polarity None, install external fuse None Vdc On/Off Remote Control Power on or off, referred to -Vin 0 13.5 Vdc Output Power 0 210 W Current-limited, no damage, Output Current 017A short-circuit protected Storage Temperature Range Vin = Zero (no power) -55 125 °C Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifi cations Table is not implied or recommended. INPUT Conditions ➀ ➂ Operating voltage range 18 48 75 Vdc Recommended External Fuse Fast blow 20 A Start-up threshold, measured at 50% load Rising input voltage 16.5 17.5 17.9 Vdc Undervoltage shutdown, measured at 50% load Falling input voltage 15 16 17 Vdc Overvoltage protection Rising input voltage None Vdc Reverse Polarity Protection None, install external fuse; see technical notes None Vdc Internal Filter Type L-C Input current Full Load Conditions Vin = nominal 4.52 4.76 A Low Line Vin = minimum 12.06 12.69 A Inrush Transient Vin = 48V. 0.05 TBD A2-Sec. Output in Short Circuit 50 100 mA No Load input current Iout = minimum, unit=ON 80 150 mA Shut down mode input current 5 6.5 mA Refl ected (back) ripple current ➁ Measured at input with specifi ed fi lter 15 25 mA, RMS Back Ripple Current, No Filtering 500 525 mA-p-p Back Ripple Current, with 22μF external 300 400 mA-p-p input capacitor Pre-biased startup External output voltage < Vset Monotonic GENERAL and SAFETY Effi ciency Vin=48V, full load 90 92 % Vin=18V 90 92 % Isolation Isolation Voltage, input to output With or without baseplate 2250 Vdc Isolation Voltage, input to baseplate With baseplate 1500 Vdc Isolation Voltage, output to baseplate With baseplate 1500 Vdc Insulation Safety Rating basic Isolation Resistance 100 MΩ Isolation Capacitance 1500 pF Safety (certifi ed to the following UL-60950-1, CSA-C22.2 No.60950-1, Yes requirements) IEC/EN60950-1, 2nd edition Per Telcordia SR-332, issue 1, class 3, ground 3 Calculated MTBF TBC Hours x 10 fi xed, Tambient=+25°C DYNAMIC CHARACTERISTICS Fixed Switching Frequency 160 180 200 KHz Power On, to Vout regulation band, Startup Time 60 65 mS 100% resistive load Startup Time Remote ON to Vout Regulated 60 65 mS Dynamic Load Response 50-75-50% load step to 3% error band 220 275 μSec Dynamic Load Peak Deviation same as above ±1100 ±1300 mV FEATURES and OPTIONS Remote On/Off Control ➃ “N” suffi x: Negative Logic, ON state ON = pin grounded or external voltage 0 1 Vdc Negative Logic, OFF state OFF = pin open or external voltage 3.5 13.5 Vdc Control Current open collector/drain 1 2 mA “P” suffi x: Positive Logic, ON state ON = pin open or external voltage 3.5 13.5 V Positive Logic, OFF state OFF = ground pin or external voltage 0 1 V Control Current open collector/drain 1 2 mA Base Plate "B" suffi x optional www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 3 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters FUNCTIONAL SPECIFICATIONS, (CONT.) OUTPUT Conditions ➀ Minimum Typical/Nominal Maximum Units Total Output Power 0.0 204 210 W Voltage Setting Accuracy, fi xed output At 50% load, not user adjustable 11.64 12 12.36 Vdc Overvoltage Protection Via magnetic feedback 15 Vdc Current Output Current Range 0.0 17 17 A Minimum Load No minimum load Current Limit Inception 97% of Vnom., cold condition 19 21 23 A Short Circuit Hiccup technique, autorecovery within 1.25% Short Circuit Current 56 A of Vout Short Circuit Duration Output shorted to ground, no damage Continuous (remove short for recovery) Short circuit protection method Hiccup current limiting Non-latching Regulation ➄ Line Regulation Vin=min. to max., Vout=nom., full load ±0.65 % of Vout Load Regulation Iout=min. to max., Vin=nom. ±1.5 % of Vout 5 Hz- 20 MHz BW, Cout=1μF MLCC paralleled 100 120 mV pk-pk Ripple and Noise ➅ with 10μF tantalum Temperature Coeffi cient At all outputs 0.02 % of Vout./°C Maximum Capacitive Loading Full resistive load, low ESR 0 5000 μF MECHANICAL (Through Hole Models) Outline Dimensions (no baseplate) 2.3x1.45x0.46 max. Inches (Please refer to outline drawing) LxWxH 58.4x36.8x11.68 mm Outline Dimensions (with baseplate) 2.3x1.45x0.5 Inches 58.4x36.8x12.7 mm Weight No baseplate 1.6 Ounces No baseplate 45 Grams With baseplate 2.24 Ounces With baseplate 63.5 Grams Through Hole Pin Diameter 0.04 & 0.06 Inches 1.016 & 1.52 mm Through Hole Pin Material Copper alloy TH Pin Plating Metal and Thickness Nickel subplate 50 μ-inches Gold overplate 5 μ-inches Baseplate Material Aluminum ENVIRONMENTAL Operating Ambient Temperature Range See derating curves -40 85 °C Operating Case Temperature With baseplate, no derating -40 110 °C Storage Temperature Vin = Zero (no power) -55 125 °C Thermal Protection/Shutdown Measured in center 115 125 130 °C Electromagnetic Interference External fi lter is required Conducted, EN55022/CISPR22 B Class Radiated, EN55022/CISPR22 B Class RoHS rating RoHS-6 Notes ➀ Unless otherwise noted, all specifi cations apply at Vin = nominal, nominal output voltage and full ➂ All models are stable and regulate to specifi cation under no load. output load. General conditions are near sea level altitude, no base plate installed and natural ➃ The Remote On/Off Control is referred to -Vin. convection airfl ow unless otherwise specifi ed. All models are tested and specifi ed with external ➄ Regulation specifi cations describe the output voltage changes as the line voltage or load current parallel 1 μF and 10 μF multi-layer ceramic output capacitors and a 22μF external input capacitor is varied from its nominal or midpoint value to either extreme. The load step is ±25% of full load (see Technical Notes). All capacitors are low-ESR types wired close to the converter. These capaci- current. tors are necessary for our test equipment and may not be needed in the user’s application. ➅ Output Ripple and Noise is measured with Cout = 1 μF || 10 μF, 20 MHz oscilloscope bandwidth ➁ Input (back) ripple current is tested and specifi ed over 5 Hz to 20 MHz bandwidth. Input fi ltering is and full resistive load. Cin = 33 μF/100V, Cbus = 220μF/100V and Lbus = 12 μH. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 4 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE DATA, UWQ-12/17-Q48NB-C Effi ciency vs. Line Voltage and Load Current @ +25°C Maximum Current Temperature Derating at sea level (Vin = 24V, air fl ow from Pin 1 to Pin 4 on PCB, with baseplate) 94 92 18 90 88 17 86 16 84 VIN = 18V 82 15 V IN = 24V 80 VIN = 36V 14 78 VIN = 48V 76 13 0.33 m/s (65 LFM) VIN = 60V 0.5 m/s (100 LFM) 74 12 1.0 m/s (200 LFM) VIN = 75V 72 1.5 m/s (300 LFM) 70 11 2.0 m/s (400 LFM) 68 10 66 64 9 62 8 60 30 35 40 45 50 55 60 65 70 75 80 85 12 34 567 89 10 11 12 13 14 15 16 17 Ambient Temperature (°C) Load Current (Amps) Maximum Current Temperature Derating at sea level Maximum Current Temperature Derating at sea level (Vin = 36V, air fl ow from Pin 1 to Pin 4 on PCB, with baseplate) (Vin = 48V, air fl ow from Pin 1 to Pin 4 on PCB, with baseplate) 18 18 17 17 16 16 15 15 14 14 0.33 m/s (65 LFM) 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 13 13 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.0 m/s (200 LFM) 12 12 1.5 m/s (300 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 11 11 2.0 m/s (400 LFM) 10 10 9 9 8 8 30 35 40 45 50 55 60 65 70 75 80 85 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (°C) Ambient Temperature (°C) Maximum Current Temperature Derating at sea level Maximum Current Temperature Derating at sea level (Vin = 60V, air fl ow from Pin 1 to Pin 4 on PCB, with baseplate) (Vin = 75V, air fl ow from Pin 1 to Pin 4 on PCB, with baseplate) 18 18 17 16 16 14 15 12 14 13 10 12 8 0.33 m/s (65 LFM) 0.5 m/s (100 LFM) 11 0.33 m/s (65 LFM) 1.0 m/s (200 LFM) 6 0.5 m/s (100 LFM) 10 1.5 m/s (300 LFM) 1.0 m/s (200 LFM) 2.0 m/s (400 LFM) 4 1.5 m/s (300 LFM) 9 2.0 m/s (400 LFM) 2 8 30 35 40 45 50 55 60 65 70 75 80 85 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (°C) Ambient Temperature (°C) www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 5 of 17 Output Current (Amps) Output Current (Amps) Efficiency (%) Output Current (Amps) Output Current (Amps) Output Current (Amps) UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE DATA, UWQ-12/17-Q48NB-C Maximum Current Temperature Derating at sea level Maximum Current Temperature Derating at sea level Vin = 24V (air fl ow from Pin 1 to Pin 4 on PCB), no baseplate Vin = 36V (air fl ow from Pin 1 to Pin 4 on PCB), no baseplate 18 18 17 17 16 16 15 15 14 14 13 13 0.33 m/s (65 LFM) 0.33 m/s (65 LFM) 12 12 0.5 m/s (100 LFM) 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.0 m/s (200 LFM) 11 11 1.5 m/s (300 LFM) 1.5 m/s (300 LFM) 10 10 2.0 m/s (400 LFM) 2.0 m/s (400 LFM) 9 9 8 8 30 35 40 45 50 55 60 65 70 75 80 85 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (°C) Ambient Temperature (°C) Maximum Current Temperature Derating at sea level Stepload Transient Response (Vin=48V, Iout=50-75-50% of Imax, Cload=1μF || 10μF, (Vin = 48V, air fl ow from Pin 1 to Pin 4 on PCB, no baseplate) Io=10A/div, Ta=+25°C) Ch2=Vout, Ch4=Iout 18 17 16 15 14 13 0.33 m/s (65 LFM) 12 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 11 1.5 m/s (300 LFM) 10 2.0 m/s (400 LFM) 9 8 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (°C) Stepload Transient Response (Vin=48V, Iout=25-75-25% of Imax, Cload=1μF || 10μF, Stepload Transient Response (Vin=48V, Iout=50-75-50% of Imax, Cload=5000μF, Io=5A/div, Ta=+25°C) Ch2=Vout, Ch4=Iout Io=5A/div, Ta=+25°C) Ch2=Vout, Ch4=Iout www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 6 of 17 Output Current (Amps) Output Current (Amps) Output Current (Amps) UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE DATA, UWQ-12/17-Q48NB-C Start-up Delay (Vin=48V, Iout=0A, Cload=0, Ta=+25°C) Ch1= Vin, Ch2= Vout Start-up Delay (Vin=48V, Iout=17A, Cload=0, Ta=+25°C) Ch1= Vin, Ch2= Vout Start-up Delay (Vin=48V, Iout=17A, Cload=5000μF, Ta=+25°C) Ch1= Vin, Ch2= Vout On/Off Enable Delay (Vin=48V, Vout=nom, Iout=0A, Ta=+25°C) Ch1= Enable, Ch2= Vout. On/Off Enable Delay (Vin=48V, Vout=nom, Iout=17A, Ta=+25°C) Ch1= Enable, Ch2= Vout. On/Off Enable Delay (Vin=48V, Vout=nom, Iout=17A, Cload=5000μF, Ta=+25°C) Ch1= Enable, Ch2= Vout. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 7 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters PERFORMANCE DATA, UWQ-12/17-Q48NB-C Output ripple and Noise (Vin=48V, Iout=0A, Cload= 1μF || 10μF, Ta=+25°C, BW=20Mhz) Output ripple and Noise (Vin=48V, Iout=17A, Cload= 1μF || 10μF, Ta=+25°C, BW=20Mhz) Thermal image with hot spot at 9.56A with 25°C ambient temperature. Natural convention is used with no forced airfl ow. Identifi able and recommended maximum value to be verifi ed in application. Vin=48V, Q5 max temp=128°C/IPC9592 guidelines. (+Vin) (+Vo) (-Vin) (-Vo) www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 8 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters MECHANICAL SPECIFICATIONS (OPEN FRAME) TOP VIEW END VIEW END VIEW 58.4 [11.68] 4.78 2.30 0.46 0.188* 36.8 1° MAX 1.45 (ALL PINS) 0.26 0.010 Mtg Plane MIN SIDE VIEW BOTTOM CLEARANCE *Alternate pin lengths available (Contact Murata Power Solutions for information). Pin location dimensions apply at circuit board level. .062 SHOULDER .083 SHOULDER MATERIAL: (AT 40 MIL PINS) (AT 60 MIL PINS) .040 PINS: COPPER ALLOY .060 PINS: COPPER ALLOY 1.02±0.05 1.52±0.05 FINISH: (ALL PINS) 0.040±.002 0.060±.002 GOLD (5u"MIN) OVER NICKEL (50u" MIN) @ PINS 1-3, 9 @ PINS 4 & 8 50.80 2.000 REF 3.8 50.80 0.15 2.000 7.61 0.300 3 4 15.24 C L 0.600 2 1 8 BOTTOM VIEW Dimensions are in inches (mm) shown for ref. only. I/O Connections (pin side view) Third Angle Projection Pin Function Pin Function 1 +Vin 4 -Vout 2 Remote On/Off Control 3 -Vin 8 +Vout Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 9 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters MECHANICAL SPECIFICATIONS (BASEPLATE) 4x M3x0.5 THREADED HOLE (.10 MAX SCREW PENETRATION) TOP VIEW 58.4 END VIEW END VIEW 2.30 12.7 47.24 4.78 0.50 1.860 0.188 * 36.8 26.16 1° MAX 1.45 1.030 (ALL PINS) 0.26 0.010 Mtg Plane MIN SIDE VIEW BOTTOM CLEARANCE OPTIONAL BASEPLATE *Alternate pin lengths available (Contact Murata Power Solutions for information). 'B' OPTION Pin location dimensions apply at circuit board level. .062 SHOULDER .083 SHOULDER (AT 40 MIL PINS) (AT 60 MIL PINS) MATERIAL: .040 PINS: COPPER ALLOY 1.02±0.05 1.52±0.05 .060 PINS: COPPER ALLOY 0.040±.002 .060±.002 FINISH: (ALL PINS) @ PINS 1-3, 9 @ PINS 4 & 8 GOLD (5u"MIN) OVER NICKEL (50u" MIN) 50.80 2.000 REF 3.8 50.80 0.15 2.000 7.61 0.300 3 4 2 15.24 C 0.600 L 1 8 BOTTOM VIEW Dimensions are in inches (mm) shown for ref. only. I/O Connections (pin side view) Third Angle Projection Pin Function Pin Function 1 +Vin 4 -Vout 2 Remote On/Off Control 3 -Vin 8 +Vout Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 10 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters RECOMMENDED FOOTPRINT Recommended Footprint (view through converter) REF: DOSA Standard Specification for Quarter-Brick DC/DC Converters FINISHED HOLE SIZES @ PINS 1-3 (PER IPC-D-275, LEVEL C) TOP VIEW 0.048-0.062 C L (PRI) (SEC) 1 8 7.62 0.300 37.3 2 C C 1.47 L L 7.62 0.300 4 3 FINISHED HOLE SIZES @ PINS 4 & 8 0.100 MIN (PER IPC-D-275, LEVEL C) 25.4 @ 1-4, 8 0.070-0.084 1.00 FOR PIN 50.80 SHOULDERS 2.000 58.9 2.32 It is recommended that no parts be placed beneath converter (hatched area). Dimensions are in inches (mm) shown for ref. only. I/O Connections (pin side view) Third Angle Projection Pin Function Pin Function 1 +Vin 4 -Vout 2 Remote On/Off Control 3 -Vin 8 +Vout Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 11 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters STANDARD PACKAGING 9.92 9.92 (251.97) (251.97) REF REF Each static dissipative polyethylene foam tray accommodates 15 converters in a 3 x 5 array. 0.88 (22.35) REF 2.75 (69.85) ±.25 closed height 10.50 (266.7) ±.25 11.00 (279.4) ±.25 Carton accommodates two (2) trays yielding 30 converters per carton Dimensions are in inches (mm) shown for ref. only. Third Angle Projection Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 12 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters a small ceramic capacitor is suffi cient. Since it is diffi cult to totally characterize TECHNICAL NOTES all applications, some experimentation may be needed. Note that external input Input Fusing capacitors must accept high speed switching currents. Certain applications and/or safety agencies may require fuses at the inputs of Because of the switching nature of DC/DC converters, the input of these power conversion components. Fuses should also be used when there is the converters must be driven from a source with both low AC impedance and possibility of sustained input voltage reversal which is not current-limited. For adequate DC input regulation. Performance will degrade with increasing input greatest safety, we recommend a fast blow fuse installed in the ungrounded inductance. Excessive input inductance may inhibit operation. The DC input input supply line. regulation specifi es that the input voltage, once operating, must never degrade The installer must observe all relevant safety standards and regulations. For below the Shut-Down Threshold under all load conditions. Be sure to use safety agency approvals, install the converter in compliance with the end-user adequate trace sizes and mount components close to the converter. safety standard. I/O Filtering, Input Ripple Current and Output Noise Input Reverse-Polarity Protection All models in this converter series are tested and specifi ed for input refl ected If the input voltage polarity is reversed, an internal diode will become forward ripple current and output noise using designated external input/output compo- biased and likely draw excessive current from the power source. If this source nents, circuits and layout as shown in the fi gures below. External input capaci- is not current-limited or the circuit appropriately fused, it could cause perma- tors (CIN in the fi gure) serve primarily as energy storage elements, minimizing nent damage to the converter. line voltage variations caused by transient IR drops in the input conductors. Users should select input capacitors for bulk capacitance (at appropriate Input Under-Voltage Shutdown and Start-Up Threshold frequencies), low ESR and high RMS ripple current ratings. In the fi gure below, Under normal start-up conditions, converters will not begin to regulate properly the CBUS and LBUS components simulate a typical DC voltage bus. Your specifi c until the rising input voltage exceeds and remains at the Start-Up Threshold system confi guration may require additional considerations. Please note that the Voltage (see Specifi cations). Once operating, converters will not turn off until values of CIN, LBUS and CBUS may vary according to the specifi c converter model. the input voltage drops below the Under-Voltage Shutdown Limit. Subsequent restart will not occur until the input voltage rises again above the Start-Up Threshold. This built-in hysteresis prevents any unstable on/off operation at a TO CURRENT OSCILLOSCOPE single input voltage. PROBE +VIN Users should be aware however of input sources near the Under-Voltage Shut- LBUS + down whose voltage decays as input current is consumed (such as capacitor – inputs), the converter shuts off and then restarts as the external capacitor re- VIN CBUS CIN + charges. Such situations could oscillate. To prevent this, make sure the operating – input voltage is well above the UV Shutdown voltage AT ALL TIMES. −VIN Start-Up Delay CIN = 33μF, ESR < 200mΩ @ 100kHz Assuming that the output current is set at the rated maximum, the Vin to Vout Start- CBUS = 220μF, 100V LBUS = 12μH Up Delay (see Specifi cations) is the time interval between the point when the rising input voltage crosses the Start-Up Threshold and the fully loaded regulated output Figure 2. Measuring Input Ripple Current voltage enters and remains within its specifi ed regulation band. Actual measured times will vary with input source impedance, external input capacitance, input volt- age slew rate and fi nal value of the input voltage as it appears at the converter. In critical applications, output ripple and noise (also referred to as periodic and random deviations or PARD) may be reduced by adding fi lter elements such as These converters include a soft start circuit to moderate the duty cycle of the multiple external capacitors. Be sure to calculate component temperature rise PWM controller at power up, thereby limiting the input inrush current. from refl ected AC current dissipated inside capacitor ESR. The On/Off Remote Control interval from inception to VOUT regulated assumes Floating Outputs that the converter already has its input voltage stabilized above the Start-Up Since these are isolated DC/DC converters, their outputs are “fl oating” with Threshold before the On command. The interval is measured from the On com- respect to their input. The essential feature of such isolation is ideal ZERO mand until the output enters and remains within its specifi ed regulation band. CURRENT FLOW between input and output. Real-world converters however do The specifi cation assumes that the output is fully loaded at maximum rated exhibit tiny leakage currents between input and output (see Specifi cations). current. These leakages consist of both an AC stray capacitance coupling component Input Source Impedance and a DC leakage resistance. When using the isolation feature, do not allow These converters will operate to specifi cations without external components, the isolation voltage to exceed specifi cations. Otherwise the converter may assuming that the source voltage has very low impedance and reasonable in- be damaged. Designers will normally use the negative output (-Output) as put voltage regulation. Since real-world voltage sources have fi nite impedance, the ground return of the load circuit. You can however use the positive output performance is improved by adding external fi lter components. Sometimes only (+Output) as the ground return to effectively reverse the output polarity. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 13 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters CAUTION: If you exceed these Derating guidelines, the converter may have an unplanned Over Temperature shut down. Also, these graphs are all collected near Sea Level altitude. Be sure to reduce the derating for higher altitude. +VOUT Output Overvoltage Protection (OVP) SCOPE RLOAD C1 C2 This converter monitors its output voltage for an over-voltage condition using an on-board electronic comparator. The signal is optically coupled to the pri- −VOUT mary side PWM controller. If the output exceeds OVP limits, the sensing circuit will power down the unit, and the output voltage will decrease. After a time-out period, the PWM will automatically attempt to restart, causing the output volt- age to ramp up to its rated value. It is not necessary to power down and reset C1 = 1μF the converter for this automatic OVP-recovery restart. C2 = 10μF LOAD 2-3 INCHES (51-76mm) FROM MODULE If the fault condition persists and the output voltage climbs to excessive levels, Figure 3. Measuring Output Ripple and Noise (PARD) the OVP circuitry will initiate another shutdown cycle. This on/off cycling is referred to as “hiccup” mode. Minimum Output Loading Requirements Output Fusing These converters employ a synchronous rectifi er design topology. All models The converter is extensively protected against current, voltage and temperature regulate within specifi cation and are stable under no load to full load conditions. extremes. However, your application circuit may need additional protection. In the Operation under no load might however slightly increase output ripple and noise. extremely unlikely event of output circuit failure, excessive voltage could be applied to your circuit. Consider using an appropriate external protection. Thermal Shutdown To protect against thermal over-stress, these converters include thermal shut- Current Limiting (Power limit with current mode control) down circuitry. If environmental conditions cause the temperature of the DC/ As power demand increases on the output and enters the specifi ed “limit DC’s to rise above the Operating Temperature Range up to the shutdown tem- inception range” (current in voltage mode and power in current mode) limiting perature, an on-board electronic temperature sensor will power down the unit. circuitry activates in the DC-DC converter to limit/restrict the maximum current When the temperature decreases below the turn-on threshold, the converter or total power available. In voltage mode, current limit can have a “constant or will automatically restart. There is a small amount of hysteresis to prevent foldback” characteristic. In current mode, once the current reaches a certain rapid on/off cycling. CAUTION: If you operate too close to the thermal limits, the range the output voltage will start to decrease while the output current con- converter may shut down suddenly without warning. Be sure to thoroughly test tinues to increase, thereby maintaining constant power, until a maximum peak your application to avoid unplanned thermal shutdown. current is reached and the converter enters a “hiccup” (on off cycling) mode of operation until the load is reduced below the threshold level, whereupon it will Temperature Derating Curves return to a normal mode of operation. Current limit inception is defi ned as the The graphs in this data sheet illustrate typical operation under a variety of condi- point where the output voltage has decreased by a pre-specifi ed percentage tions. The Derating curves show the maximum continuous ambient air temperature (usually a 2% decrease from nominal). and decreasing maximum output current which is acceptable under increasing forced airfl ow measured in Linear Feet per Minute (“LFM”). Note that these are Short Circuit Condition (Current mode control) AVERAGE measurements. The converter will accept brief increases in temperature The short circuit condition is an extension of the “Current Limiting” condition. and/or current or reduced airfl ow as long as the average is not exceeded. When the monitored peak current signal reaches a certain range, the PWM controller’s outputs are shut off thereby turning the converter “off.” This is Note that the temperatures are of the ambient airfl ow, not the converter itself followed by an extended time out period. This period can vary depending on which is obviously running at higher temperature than the outside air. Also note other conditions such as the input voltage level. Following this time out period, that “natural convection” is defi ned as very low fl ow rates which are not using the PWM controller will attempt to re-start the converter by initiating a “normal fan-forced airfl ow. Depending on the application, “natural convection” is usu- start cycle” which includes softstart. If the “fault condition” persists, another ally about 30-65 LFM but is not equal to still air (0 LFM). “hiccup” cycle is initiated. This “cycle” can and will continue indefi nitely until Murata Power Solutions makes Characterization measurements in a closed such time as the “fault condition” is removed, at which time the converter will cycle wind tunnel with calibrated airfl ow. We use both thermocouples and an resume “normal operation.” Operating in the “hiccup” mode during a fault infrared camera system to observe thermal performance. As a practical matter, condition is advantageous in that average input and output power levels are it is quite diffi cult to insert an anemometer to precisely measure airfl ow in held low preventing excessive internal increases in temperature. most applications. Sometimes it is possible to estimate the effective airfl ow if you thoroughly understand the enclosure geometry, entry/exit orifi ce areas and the fan fl owrate specifi cations. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 14 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters Remote On/Off Control On the input side, a remote On/Off Control can be specifi ed with either positive or negative logic as follows: +VCC Positive: Models equipped with positive logic are enabled when the On/Off pin is left open or is pulled high to +13.5VDC with respect to –VIN. An internal bias current causes the open pin to rise to +VIN. Positive-logic devices are disabled ON/OFF when the On/Off is grounded or brought to within a low voltage (see Specifi ca- CONTROL tions) with respect to –VIN. Negative: Models with negative logic are on (enabled) when the On/Off is -VIN grounded or brought to within a low voltage (see Specifi cations) with respect to –VIN. The device is off (disabled) when the On/Off is left open or is pulled high to +13.5VDC Max. with respect to –VIN. Figure 4. Driving the On/Off Control Pin (suggested circuit) Dynamic control of the On/Off function should be able to sink the specifi ed signal current when brought low and withstand specifi ed voltage when brought high. Be aware too that there is a fi nite time in milliseconds (see Specifi cations) between the time of On/Off Control activation and stable, regulated output. This time will vary slightly with output load type and current and input conditions. There are two CAUTIONs for the On/Off Control: CAUTION: While it is possible to control the On/Off with external logic if you carefully observe the voltage levels, the preferred circuit is either an open drain/open collector transistor or a relay (which can thereupon be controlled by logic). The On/Off prefers to be set at approx. +13.5V (open pin) for the ON state, assuming positive logic. CAUTION: Do not apply voltages to the On/Off pin when there is no input power voltage. Otherwise the converter may be permanently damaged. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 15 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters Emissions Performance [3] Conducted Emissions Test Results Murata Power Solutions measures its products for radio frequency emissions [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [ [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [ [ [4 [4 [4 [4 [4 [4 [ [ [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4 [4] 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] La La La La Layout Recommendations yo yo yo yo o o o out ut ut ut R R R Rec ec e ec e ec e e e e e om om om om m m m m m m m mme me m me m me m m m m m nd nd nd nd n nd n n n n n nd d dat at at at at at a a at at at t t t tio iio io io o o o o o o o o o ons ns n ns n n ns n n n n n n against the EN 55022 and CISPR 22 standards. Passive resistance loads are employed and the output is set to the maximum voltage. If you set up your own emissions testing, make sure the output load is rated at continuous power while doing the tests. The recommended external input and output capacitors (if required) are includ- ed. Please refer to the fundamental switching frequency. All of this information is listed in the Product Specifi cations. An external discrete fi lter is installed and the circuit diagram is shown below. UWQ EMI 200W Test Card Resistive 48Vdc in, 12Vout, 17Amps Load UUT V+ Resistive Black C16 Vin + Vout + Load C8 C8 C8 C8 C8 C8 C7 inside a L3 L1 metal C17 container V- Vin - Vout - Graph 1. Conducted emissions performance, CISPR/EN55022, Class B, full load Most applications can use the fi ltering which is already installed inside the converter or with the addition of the recommended external capacitors. For greater emissions suppression, consider additional fi lter components and/or Figure 5. Conducted Emissions Test Circuit shielding. Emissions performance will depend on the user’s PC board layout, the chassis shielding environment and choice of external components. Please [1] Conducted Emissions Parts List refer to Application Note GEAN02 for further discussion. Reference Part Number Description Vendor Since many factors affect both the amplitude and spectra of emissions, we L1 PE-62913 1mH,6A Pulse recommend using an engineer who is experienced at emissions suppression. L3 500uH,10A, MPS 500uH,10A Murata C8 2.2μFd Murata Qty 2 - Electrolytic Capacitor C7 VZ Series Panasonic 22μFd, 100V C16, C17 .22μFd Unknown [2] Conducted Emissions Test Equipment Used Rohde & Schwarz EMI Test Receiver (9KHz – 1000MHz) ESPC Rohde & Schwarz Software ESPC-1 Ver. 2.20 HP11947A Transient Limiter (Agilent) OHMITE 25W – Resistor combinations DC Source Programmable DC Power Supply Model 62012P-100-50 www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 16 of 17 UWQ-12/17-Q48 Series Wide Input, Isolated DOSA Quarter Brick DC/DC Converters Vertical Wind Tunnel Murata Power Solutions employs a computer controlled custom-designed closed loop vertical wind tunnel, infrared video camera system, and test instrumentation for accurate airfl ow and heat dissipation analysis of power products. IR Transparent The system includes a precision low fl ow-rate anemometer, optical window Variable variable speed fan, power supply input and load controls, Unit under speed fan temperature gauges, and adjustable heating element. test (UUT) The IR camera monitors the thermal performance of the IR Video Unit Under Test (UUT) under static steady-state conditions. A Camera special optical port is used which is transparent to infrared wavelengths. Both through-hole and surface mount converters are sol- dered down to a host carrier board for realistic heat absorp- tion and spreading. Both longitudinal and transverse airfl ow Heating studies are possible by rotation of this carrier board since element there are often signifi cant differences in the heat dissipation Precision in the two airfl ow directions. The combination of adjust- low-rate able airfl ow, adjustable ambient heat, and adjustable Input/ anemometer Output currents and voltages mean that a very wide range of 3” below UUT measurement conditions can be studied. The collimator reduces the amount of turbulence adjacent to Ambient the UUT by minimizing airfl ow turbulence. Such turbulence temperature infl uences the effective heat transfer characteristics and sensor gives false readings. Excess turbulence removes more heat from some surfaces and less heat from others, possibly Airflow causing uneven overheating. collimator Both sides of the UUT are studied since there are different ther- mal gradients on each side. The adjustable heating element and fan, built-in temperature gauges, and no-contact IR camera mean that power supplies are tested in real-world conditions. Figure 6. Vertical Wind Tunnel Soldering Guidelines Murata Power Solutions recommends the specifi cations below when installing these converters. These specifi cations vary depending on the solder type. Exceeding these specifi ca- tions may cause damage to the product. Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers. Wave Solder Operations for through-hole mounted products (THMT) For Sn/Ag/Cu based solders: For Sn/Pb based solders: Maximum Preheat Temperature 115° C. Maximum Preheat Temperature 105° C. Maximum Pot Temperature 270° C. Maximum Pot Temperature 250° C. Maximum Solder Dwell Time 7 seconds Maximum Solder Dwell Time 6 seconds This product is subject to the following operating requirements Murata Power Solutions, Inc. and the Life and Safety Critical Application Sales Policy: 129 Flanders Road, Westborough, MA 01581 U.S.A. Refer to: http://www.murata-ps.com/requirements/ ISO 9001 and 14001 REGISTERED Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifi cations are subject to change without notice. © 2018 Murata Power Solutions, Inc. www.murata-ps.com/support MDC_UWQ-12/17-Q48 Series.A07 Page 17 of 17
Frequently asked questions
How does Electronics Finder differ from its competitors?
Is there a warranty for the UWQ-12/17-Q48N-C?
Which carrier will Electronics Finder use to ship my parts?
Can I buy parts from Electronics Finder if I am outside the USA?
Which payment methods does Electronics Finder accept?
Why buy from GID?
Quality
We are industry veterans who take pride in our work
Protection
Avoid the dangers of risky trading in the gray market
Access
Our network of suppliers is ready and at your disposal
Savings
Maintain legacy systems to prevent costly downtime
Speed
Time is of the essence, and we are respectful of yours
Manufacturers



What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods