Electronics Finder chervon right Manufacturers chervon right O chervon right OMRON AUTOMATION chervon right D4E1G24N
About product Specifications Datasheet FAQ

OMRON AUTOMATION D4E1G24N

Image of OMRON AUTOMATION D4E1G24N

Description

Switch Limit N.O./N.C. SPDT Top Roller Lever Cable 5A 250VAC 250VDC Linear Screw Mount
D4E1G24N

Part Number

D4E1G24N

Price

Request Quote

Manufacturer

OMRON AUTOMATION

Lead Time

Request Quote

Category

Switches »  Switch Limit

Specifications

Manufacturer

Omron Automation

Manufacturers Part #

D4E1G24N

Industry Aliases

D4E-1G24N

Sub-Category

Limit Switches

Factory Pack Quantity

1

Datasheet

pdf file

d4e-_n_ds_e_6_1_csm585.pdf

1780 KiB

Extracted Text

Small Sealed Switch D4E-@N CSM_D4E-_N_DS_E_6_1 Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E • Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action and long life expectancy. • Protection cover protects the built-in switch from dust and oil. Plunger incorporates a tough seal cap that lasts for a long time. • One touch connector eliminates need for tedious wiring operations and reduces downtime for wiring and maintenance (models with standard, easy-to-use screw For the most recent information on models that have been certified for terminals are also available). safety standards, refer to your OMRON website. • Minute load model with gold cladding is optimal for electronic control. • Molded terminal types as well as molded terminal types with operating indicator lamps are available for screw terminal systems. • Approved by EN, UL, CSA, and CCC (Chinese standard). (Ask your OMRON representative for Information on approved models.) • No difference in mounting pitch and characteristics between D4E-@N and D4E models. Be sure to read Safety Precautions on page 9 to 10 and Safety Precautions for All Limit Switches. Model Number Structure Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.) D4E-@@@@@N (1)(2) (3) (4) (1) Rated Current (3) Terminals (4) Operation Indicator 1: 5 A at 125 VAC 00: AC connector None: Without operation indicator (1 A at 125 VAC/30 VDC for model with a 10: DC connector L: Neon lamp (250 VAC) connector) 20: Screw terminals without a cable L2: LED (24 VDC) 2: 0.1 A at 125 VAC 21: Screw terminals with a cable (right-hand) Note: Only the molded terminal models can be equipped with an operation indicators. (0.1 A at 125 VAC/30 VDC for model with a 22: Screw terminals with a cable (left-hand) connector) 23: Molded terminals with a cable (right-hand) 24: Molded terminals with a cable (left-hand) (2) Actuator (Cable is S-FLEX VCTF 3 m) Note: The terminal specifications in model numbers are A: Roller plunger not the same for D4E-N and D4E Switches. B: Crossroller plunger Comparison of New and Old Molded C: Plunger Terminal Models D: Sealed roller plunger E: Sealed crossroller plunger Model F: Sealed plunger Location of D4E-N D4E G: Roller lever lead outlet H: One-way action roller lever Right-hand D4E-@@23N D4E-@@21 Left-hand D4E-@@24N D4E-@@23 1 D4E-@N Ordering Information Type One-touch connector type Screw terminal type General-purpose Micro load General-purpose Micro load with General-purpose Micro load without cable without cable with cable cable Actuator Model Model Model Model Model Model Roller plunger D4E-1A@0N D4E-2A10N D4E-1A20N D4E-2A20N D4E-1A21N D4E-2A21N Crossroller D4E-1B@0N D4E-2B10N D4E-1B20N D4E-2B20N D4E-1B21N D4E-2B21N plunger D4E-1C@0N D4E-2C@0N D4E-1C20N D4E-2C20N D4E-1C21N D4E-2C21N Plunger Sealed roller D4E-1D@0N D4E-2D10N D4E-1D20N D4E-2D20N D4E-1D21N D4E-2D21N plunger Sealed crossroller D4E-1E@0N --- D4E-1E20N D4E-2E20N D4E-1E21N D4E-2E21N plunger D4E-1F@0N D4E-2F10N D4E-1F20N D4E-2F20N D4E-1F21N D4E-2F21N Sealed plunger D4E-1G@0N D4E-2G10N D4E-1G20N D4E-2G20N D4E-1G21N D4E-2G21N Roller lever One-way action D4E-1H00N --- D4E-1H20N D4E-2H20N D4E-1H21N --- roller lever Note: 1. When ordering, specify the current type by replacing the blank box of the model number with 0 for AC connector or 1 for DC connector. 2. For the plunger and lever actuator models, the NC and NO terminal indicators are reversed. 3. Models are also available with molded terminals and with molded terminals and operation indicators. Refer to page 8. Plug For models with connectors, select one of the specified Cables with Connectors (sockets) from the following table. Applicable limit Current No. of Type Cable length Model switches Type conductors 2 m XS2F-A421-D90-F Straight D4E-@@00N AC 5 m XS2F-A421-G90-F 4 2 m XS2F-D421-D80-F D4E-@@10N DC 5 m XS2F-D421-G80-F Specifications Approved Standards Agency Standard File No. Approved models UL UL508 E76675 D4E-@@20N Switches only except for Indicator-equipped Switches CSA CSA C22.2 No. 14 LR45746 D4E-@@20N Switches only except for Indicator-equipped Switches TÜV Rheinland EN60947-5-1 R9551015 Ask your OMRON representative for information on approved models. CCC (CQC) GB14048.5 2003010305086795 Ask your OMRON representative for information on approved models. Ratings Standard load Micro load NC 10 A max. Inrush current Non-inductive load (A) Inductive load (A) Non-inductive load (A) NO 10 A max. Rated voltage Resistive load Lamp load Inductive load Motor load Resistive load Note: 1. The above current ratings are for a standard current and the values in NC NO NC NO NC NO NC NO NC NO parentheses are for models with a 125 VAC 5 (1) 1.5 (1) 3 (1) 2 (1) 1 (1) 0.1 connector. 5 (1) 1.5 (1) 3 (1) 1 0.5 --- 250 VAC 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms 8 VDC 5 (1) 1.5 (1) 0.1 --- --- max. (DC). 14 VDC 5 (1) 1.5 (1) 0.1 --- --- 3. Lamp load has an inrush current of 10 30 VDC 5 (1) 1.5 (1) 0.1 --- --- times the steady-state current. 0.5 0.05 --- 125 VDC --- --- 4. Motor load has an inrush current of 6 --- --- 0.25 0.03 --- 250 VDC times the steady-state current. Standard load Micro load Minimum applicable 160 mA at 5 1 mA at 5 VDC load VDC 2 D4E-@N Approved Standard Ratings UL/CSA TÜV (EN60947-5-1), CCC (GB14048.5) A300 D4E-1 G 23 L N I II III IV Current (A) Volt-amperes (VA) Carry Voltage Model Applicable category Thermal current current Make Break Make Break Indicator and ratings (Ithe) I II III IV 120 V 60 A 6 A 10 A 7,200 720 1 @ 00 AC-14 0.5 A/125 VAC 5 A --- 240 V 30 A 3 A 1 @ 10 DC-12 0.5 A/30 VDC 5 A --- 1 @ 20, 21, 22 AC-15 2A/250 VAC 5 A --- DC-12 2A/48 VDC 1 @ 23, 24 L AC-15 2A/250 VAC 5 A Neon lamp 1 @ 23, 24 L1 DC-12 2A/12 VDC 5 A LED 1 @ 23, 24 L2 DC-12 2A/24 VDC 5 A LED Note: 1.@:Actuator variation of item II 1 @ 23, 24 L3 DC-12 2A/48 VDC 5 A LED 2. AC-14 0.5 A/125 VAC means as follows: 2 @ 00 AC-14 0.1A/125 VAC 0.5 A --- 3. Applicable category: AC-14 2 @ 10 DC-12 0.1A/30 VDC 0.5 A --- Rated operating current (Ie): 0.5 A 2 @ 20, 21, 22 AC-14 0.1A/125 VAC 0.5 A --- Rated operating voltage (Ue): 125 VAC DC-12 0.1A/48 VDC 2 @ 23, 24 L AC-14 0.1A/125 VAC 0.5 A Neon lamp 2 @ 23, 24 L1 DC-12 0.1A/12 VDC 0.5 A LED 2 @ 23, 24 L2 DC-12 0.1A/24 VDC 0.5 A LED 2 @ 23, 24 L3 DC-12 0.1A/48 VDC 0.5 A LED Characteristics Engineering Data General-purpose Models Degree of protection IP67 Mechanical 10,000,000 operations min. Electrical Durability (cosφ=1) 500,000 operations min. Operating temperature: +5°C to +30°C Durability * (5 A at 250 VAC, resistive load) Electrical Operating humidity: 40% to 70%RH. 5,000,000 operations min. 1,000 (10 mA at 24 VDC, resistive load) 700 Operating speed 0.1 mm/sec to 0.5 m/sec Operating frequency: 30 operations/min 500 cosφ= 1 Mechanical: 120 operations/min 300 Operating frequency Electrical: 30 operations/min 250 VAC Rated frequency 50/60 Hz 100 Insulation resistance 100 MΩ min. (at 500 VDC) 70 50 15 mΩ max. (initial value for the built-in switch when Contact resistance 30 tested alone) Between terminals of 1,000 VAC, 50/60 Hz for 1 min same polarity Dielectric 10 strength 7 Between each terminal and non- 1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV 5 current-carrying metal part (EN60947-5-1) 3 Rated insulation voltage (Ui) 250V Pollution degree (operating environment) 3 (EN60947-5-1) 1 Short-circuit protective device (SCPD) 10 A fuse (type gG or gI, IEC60269 approved) 03 1 2 4 5678 9 10 Switching current (A) Conditional short-circuit current 100 A (EN60947-5-1) Note: 1. The above values are initial values. Conventional enclosed thermal current (Ithe) 5 A (EN60947-5-1) 2. The above ratings may vary depending on the Protection against electric shock Class II (grounding not required with double insulation) model. Contact your OMRON representative Vibration for further details. Malfunction 10 to 55 Hz, 1.5-mm double amplitude resistance * Durability values are calculated at an operating 2 temperature of +5°C to +35°C, and an operating Destruction 1,000 m/s max. Shock humidity of 40% to 70%RH. resistance 2 Malfunction 300 m/s max. Ambient operating temperature −10°C to +80°C (with no icing) Ambient operating humidity 35% to 95%RH Weight Approx. 86 g (in case of roller plunger) Structure and Nomenclature Structure Bearing · The bearing load strength has been increased to prevent faulty Movable Plunger resetting of the bearing, which may occur when the roller is pressed with excessive force. Rubber Cap (NBR) Built-in Switch · Rubber cap provides a tight seal and · Switch cover ensures high insulation between the terminals ensures a long service life and and die-cast. Double insulation means that grounding is smooth reset at low temperatures. unnecessary. Meets UL, CSA, and EN standards. · Prevents the movable piece from being pushed in too far, and thereby contributes to a longer service life. Die-cast Case Seal Packing (NBR) · Zinc die-cast case is anti-corrosive and tough. · Seal packing withstands a pressure of 186 kPa. Wiring Ease Terminal Protection Cover · Wired made easier using · D4E-@N has a wide wiring space of (D4CC-type) plug-in connector. 10 mm horizontally. Screw Terminal · Screw terminal incorporates a M3 screw with a toothed washer. 3 4 Durability (×10 operations) D4E-@N Contact Form Screw Terminal Type Connector Type Lever Plunger For AC For DC * The position of the positioning Positioning Positioning piece is not always the same. If NC NC (COM) 1 2 (NC) (COM) 1 4 (NO) piece * piece * using an L-shaped connector causes problems in application, 2 (NC) 4 (NO) use a straight connector. COM COM NO NO Dimensions and Operating Characteristics (Unit: mm) Roller Plunger (46) 11 dia. × 4.7 stainless ±0.15 D4E-1A00N 3.5 33 6.5 sintered alloy roller 10 PT Two, panel mounting nut D4E-2A00N 2.5 mm thickness, 17 mm M14 × 1 D4E-1A10N width across flats +0.2 4.2 dia. 0 Operating force OF max. 11.77 N D4E-2A10N holes 0.5 Release force RF min. 4.90 N OP 11 4.7 holes Pretravel PT max. 1.5 mm +0.2 4.2 dia. 0 Overtravel OT min. 3 mm 8 Movement Differential MD (0.1 mm) 4.5 Operating Position OP 31.4±0.8 mm 21.5 Two, 2.1R 28.4 ( ) :Reference Value (60) 18 M12 × 1 Roller Plunger (46) 11 dia. × 4.7 stainless D4E-1A20N *1 3.5 ±0.15 6.5 33 sintered alloy roller 10 PT Two, panel mounting nut D4E-2A20N *1 2.5 mm thickness, 17 mm D4E-1A21N *2 M14 × 1 width across flats +0.2 4.2 dia. 0 Operating force OF max. 11.77 N D4E-2A21N *2 holes 0.5 Release force RF min. 4.90 N OP 11 4.7 holes Pretravel PT max. 1.5 mm +0.2 4.2 dia. 0 Overtravel OT min. 3 mm 8 Movement Differential MD (0.1 mm) 4.5 Operating Position OP 31.4±0.8 mm 21.5 Two, 2.1R 28.4 ( ) :Reference Value 16 dia. (57) 18 Cross Roller Plunger (46) 11 dia. × 4.7 stainless ±0.15 D4E-1B00N 3.5 33 6.5 sintered alloy roller 10 PT Two, panel mounting nut D4E-1B10N 2.5 mm thickness, 17 mm D4E-2B10N width across flats M14 × 1 +0.2 4.2 dia. 0 Operating force OF max. 11.77 N holes 0.5 Release force RF min. 4.90 N OP 11 4.7 holes Pretravel PT max. 1.5 mm +0.2 4.2 dia. 0 Overtravel OT min. 3 mm 8 Movement Differential MD (0.1 mm) 4.5 Operating Position OP 31.4±0.8 mm 21.5 Two, 2.1R 28.4 ( ) :Reference Value (60) 18 M12 × 1 Cross Roller Plunger (46) 11 dia. × 4.7 stainless ±0.15 D4E-1B20N *1 3.5 33 6.5 sintered alloy roller 10 PT Two, panel mounting nut D4E-2B20N *1 2.5 mm thickness, 17 mm D4E-1B21N *2 width across flats M14 × 1 +0.2 dia. 4.2 0 Operating force OF max. 11.77 N D4E-2B21N *2 holes 0.5 Release force RF min. 4.90 N OP 11 4.7 holes Pretravel PT max. 1.5 mm +0.2 4.2 dia. 0 Overtravel OT min. 3 mm 8 Movement Differential MD (0.1 mm) 4.5 Operating Position OP 31.4±0.8 mm Two, 2.1R 21.5 28.4 ( ) :Reference Value 16 dia. (57) 18 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. *1. A 5.8-dia. to 7.6-dia. cable can be applied to the seal rubber for the lead wire outlet. 2 *2. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm , 7 mm in dia.) is provided. 4 D4E-@N Plunger (46) 7.8 dia. stainless D4E-1C00N PT steel plunger ±0.15 3.5 33 6.5 D4E-2C00N +0.2 10 4.2 dia. 0 M14 × 1 Two, panel mounting nut holes D4E-1C10N 2.5 mm thickness, 17 mm Operating force OF max. 11.77 N width across flats D4E-2C10N Release force RF min. 4.90 N 0.5 11 OP 4.7 holes Pretravel PT max. 1.5 mm +0.2 4.2 dia. 0 Overtravel OT min. 3 mm 8 Movement Differential MD (0.1 mm) 4.5 Operating Position OP 25.4±0.8 mm 21.5 Two, 2.1R 28.4 ( ) :Reference Value (60) 18 M12 × 1 Plunger D4E-1C20N *1 (46) 7.8 dia. stainless PT ±0.15 3.5 33 6.5 steel plunger D4E-2C20N *1 +0.2 10 dia. 4.2 0 M14 × 1 Two, panel mounting nut holes D4E-1C21N *2 2.5 mm thickness, 17 mm Operating force OF max. 11.77 N width across flats D4E-2C21N *2 Release force RF min. 4.90 N 0.5 11 OP 4.7 holes Pretravel PT max. 1.5 mm +0.2 4.2 dia. 0 Overtravel OT min. 3 mm 8 Movement Differential MD (0.1 mm) 4.5 Operating Position OP 25.4±0.8 mm 21.5 Two, 2.1R 28.4 ( ) :Reference Value 16 dia. (57) 18 Sealed Roller Plunger (46) 11 dia. × 4.7 stainless D4E-1D00N ±0.15 3.5 33 6.5 sintered alloy roller 10 PT D4E-1D10N Sealed rubber D4E-2D10N Operating force OF max. 11.77 N Release force RF min. 4.90 N +0.2 4.2 dia. 0 OP 0.5 holes Pretravel PT max. 1.5 mm 4.7 holes Overtravel OT min. 3 mm +0.2 4.2 dia. 0 Movement Differential MD (0.1 mm) Operating Position OP 41.3±0.8 mm 4.5 21.5 Two, 2.1R ( ) :Reference Value 28.4 (60) 18 M12 × 1 Sealed Roller Plunger (46) 11 dia. × 4.7 stainless ±0.15 D4E-1D20N *1 3.5 33 6.5 sintered alloy roller 10 PT D4E-2D20N *1 Sealed rubber D4E-1D21N *2 Operating force OF max. 11.77 N D4E-2D21N *2 Release force RF min. 4.90 N Pretravel PT max. 1.5 mm +0.2 4.2 dia. OP 0 0.5 Overtravel OT min. 3 mm holes 4.7 holes Movement Differential MD (0.1 mm) +0.2 4.2 dia. 0 Operating Position OP 41.3±0.8 mm ( ) :Reference Value 4.5 21.5 Two, 2.1R 28.4 16 dia. (57) 18 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. *1. A 5.8-dia. to 7.6-dia. cable can be applied to the seal rubber for the lead wire outlet. 2 *2. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm , 7 mm in dia.) is provided. 5 D4E-@N Sealed Cross Roller Plunger (46) 11 dia. × 4.7 stainless sintered alloy roller ±0.15 3.5 33 6.5 D4E-1E00N 10 PT D4E-1E10N Sealed rubber Operating force OF max. 11.77 N Release force RF min. 4.90 N +0.2 4.2 dia. 0 0.5 Pretravel PT max. 1.5 mm holes OP 4.7 holes Overtravel OT min. 3 mm +0.2 4.2 dia. 0 Movement Differential MD (0.1 mm) Operating Position OP 41.3±0.8 mm 4.5 21.5 Two, 2.1R ( ) :Reference Value 28.4 (60) 18 M12 × 1 Sealed Cross Roller Plunger (46) 11 dia. × 4.7 stainless sintered alloy roller D4E-1E20N *1 3.5 ±0.15 6.5 33 10 PT D4E-2E20N *1 Sealed rubber D4E-1E21N *2 D4E-2E21N *2 Operating force OF max. 11.77 N Release force RF min. 4.90 N +0.2 4.2 dia. OP 0.5 0 Pretravel PT max. 1.5 mm holes 4.7 holes Overtravel OT min. 3 mm +0.2 4.2 dia. 0 Movement Differential MD (0.1 mm) Operating Position OP 41.3±0.8 mm 4.5 Two, 2.1R 21.5 ( ) :Reference Value 28.4 (57) 18 Sealed Plunger (46) 7.8 dia. stainless D4E-1F00N steel plunger ±0.15 3.5 33 6.5 10 PT D4E-1F10N Sealed rubber D4E-2F10N Operating force OF max. 11.77 N +0.2 4.2 dia. 0 0.5 Release force RF min. 4.90 N holes OP 4.7 holes Pretravel PT max. 1.5 mm +0.2 4.2 dia. 0 Overtravel OT min. 3 mm Movement Differential MD (0.1 mm) 4.5 Operating Position OP 30±0.8 mm 21.5 Two, 2.1R 28.4 ( ) :Reference Value (60) 18 M12 × 1 Sealed Plunger (46) 7.8 dia. stainless D4E-1F20N *1 steel plunger ±0.15 3.5 33 6.5 10 PT D4E-2F20N *1 Sealed rubber D4E-1F21N *2 Operating force OF max. 11.77 N +0.2 D4E-2F21N *2 4.2 dia. 0 0.5 Release force RF min. 4.90 N holes OP 4.7 holes Pretravel PT max. 1.5 mm +0.2 4.2 dia. Overtravel OT min. 3 mm 0 Movement Differential MD (0.1 mm) 4.5 Operating Position OP 30±0.8 mm 21.5 Two, 2.1R 28.4 ( ) :Reference Value 18 (57) Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. *1. A 5.8-dia. to 7.6-dia. cable can be applied to the seal rubber for the lead wire outlet. 2 *2. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm , 7 mm in dia.) is provided. 6 D4E-@N Roller Lever (46) 9.5 dia. × 4.0 stainless D4E-1G00N ±0.15 3.5 33 6.5 sintered alloy roller D4E-1G10N 0.5 PT 4.7 holes D4E-2G10N +0.2 4.2 dia. 0 holes 19.4 Operating force OF max. 3.92 N Release force RF min. 0.78 N OP +0.2 4.2 dia. 0 15 12 Pretravel PT max. 2 mm Overtravel OT min. 4 mm Movement Differential MD (0.3 mm) 21.5 Two, 2.1R 28.4 Operating Position OP 23.1±0.8 mm ( ) :Reference Value (60) 18 M12 × 1 Roller Lever (46) D4E-1G20N *1 ±0.15 3.5 33 6.5 9.5 dia. × 4.0 stainless sintered alloy roller D4E-2G20N *1 0.5 PT 4.7 holes D4E-1G21N *2 +0.2 4.2 dia. 0 Operating force OF max. 3.92 N D4E-2G21N *2 holes 19.4 Release force RF min. 0.78 N OP +0.2 Pretravel PT max. 2 mm 4.2 dia. 15 0 12 Overtravel OT min. 4 mm Movement Differential MD (0.3 mm) 21.5 Two, 2.1R Operating Position OP 23.1±0.8 mm 28.4 ( ) :Reference Value 16 dia. (57) 18 One-way Action Roller Lever (46) 9.5 dia. × 4.0 stainless ±0.15 D4E-1H00N 3.5 33 6.5 sintered alloy roller 0.5 PT 4.7 holes A Operating force OF max. 3.92 N +0.2 4.2 dia. 0 Release force RF min. 0.78 N Operating holes 19.4 OP Pretravel PT max. 2 mm direction +0.2 Overtravel OT min. 4 mm 4.2 dia. 0 15 12 Movement Differential MD (0.3 mm) Operating Position OP 34.3±0.8 mm 21.5 Two, 2.1R ( ) :Reference Value 28.4 (60) 18 M12 × 1 One-way Action Roller Lever (46) 9.5 dia. × 4.0 stainless D4E-1H20N *1 ±0.15 3.5 33 6.5 sintered alloy roller 0.5 D4E-2H20N *1 PT 4.7 holes D4E-1H21N *2 A Operating force OF max. 3.92 N +0.2 4.2 dia. 0 Release force RF min. 0.78 N Operating holes 19.4 Pretravel PT max. 2 mm OP direction Overtravel OT min. 4 mm +0.2 4.2 dia. 0 15 12 Movement Differential MD (0.3 mm) Operating Position OP 34.3±0.8 mm 21.5 Two, 2.1R ( ) :Reference Value 28.4 16 dia. 18 (57) Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. *1. A 5.8-dia. to 7.6-dia. cable can be applied to the seal rubber for the lead wire outlet. 2 *2. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm , 7 mm in dia.) is provided. 7 23R 23R 28R 28R D4E-@N Molded Terminal Models The molded-terminal model is available with Suffix by Location of Lead Outlet right-hand and left-hand leads and is Suffix for pre-wired terminal Location of recommended for use where the Switch is Example: lead outlet COM, NC, NO exposed to dust, oil or moisture. It can be used Standard type: D4E-1A20N Right-hand D4E-@@23N (1) like a screw-terminal model (with a cable), and Location of lead output: the dimensions and operating characteristics Left-hand D4E-@@24N (2) Right-hand → D4E-1A23N are the same as for standard models. Lead Supplies Specifications Nominal cross-sectional External Terminal Cable length area diameter connections (m) Leads 2 (mm ) Black: COM 3 conductors V.C.T.F. S-FLEX 0.75 3 (Standard) White: NO (2) (1) (vinyl cabtire coat) 7 mm dia. Red: NC Operation of Indicator-equipped Models • The molded terminal model may be equipped with an operation indicator (neon lamp or LED) upon request to facilitate maintenance and inspection. • The operation indicator is designed to illuminate when the Switch is not operating. (Because of the molded terminal model, any change to the Switch wiring cannot be made.) AC Operation DC Operation • The operating voltage is 90 to 250 VAC. • LED indicator is provided. • As a rectifier stack is incorporated, into the unit and no directionality exists for connection of + and −, this type can also be operated on AC. • Voltage ratings of LED indicators are as shown in the table below. Internal Voltage rating Leakage Type resistance (V) current (mA) (kΩ) L2 24 Approx. 1.2 18 Terminal protection cover Neon lamp (transparent) • There is no difference in operating characteristics between D4E- @N AC Models and corresponding D4E-@N Standard Models. • There is no difference in dimensions between D4E-@N AC Models and D4E-@N Standard Models. Example: Add “L” at the frond of “N”, which is suffix of a part number. Basic type: D4E-1A23N When placing your order for the molded terminal model with an neon Example: lamp operation indicator, specify the model number as D4E-1A23LN. Add “L2” at the frond of “N”, which is suffix of a part number. Internal Circuit Basic Model: The model number of the D4E-1A23N with a built-in Power supply 24-V LED indicator is D4E-1A23L2N. Internal Circuit Built-in switch Power supply Built-in switch Load Load Resistor Neon lamp R = 240 kΩ LED 8 D4E-@N Safety Precautions Refer to Safety Precautions for All Limit Switches. Precautions for Correct Use Operating Environment • Be sure to connect a fuse with a breaking current 1.5 to 2 times the rated current to the Limit Switch in series in order to protect the • Seal material may deteriorate if a Switch is used outdoor or where Limit Switch from damage due to short-circuiting. When using the subject to special cutting oils, solvents, or chemicals. Always Limit under the EN ratings, use a gI or gG 10-A fuse that conforms appraise performance under actual application conditions and set to IEC60269. suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting Mounting chips, dust, or dirt. The Actuator and Switch must also be protected • Secure the Switch with two M4 screws and washers. The tightening from the accumulation of cutting chips or sludge. torque applied to each terminal must be 1.18 to 1.37 N·m. Tighten Not Suitable Suitable the screws to the specified torque. An excessive tightening torque may damage the Switch and cause a malfunction. Mounting Holes Two, 4.3 dia. or M4 hole ±0.15 • Constantly subjecting a Switch to vibration or shock can result in 33 wear, which can lead to contact interference with contacts, • When mounting the panel mount-type Switch with screws on a side operation failure, reduced durability, and other problems. surface, remove the hexagonal nuts from the actuator. Excessive vibration or shock can lead to false contact operation or • When mounting the panel mount type on a panel, tighten the damage. Install Switches in locations not subject to shock and hexagonal nuts of the actuator to a torque less than 7.85 N·m. vibration and in orientations that will not produce resonance. Mounting Hole • The Switches have physical contacts. Using them in environments ±0.2 14.5 dia. containing silicon gas will result in the formation of silicon oxide (SiO2) due to arc energy. If silicon oxide accumulates on the contacts, contact interference can occur. If silicon oil, silicon filling agents, silicon cables, or other silicon products are present near the • Operating method, shape of cam or dog, operating frequency, and Switch, suppress arcing with contact protective circuits (surge the overtravel (OT) have significant effect on the service life and killers) or remove the source of silicon gas. precision of the Limit Switch. Make sure that the shape of the cam • Do not solder the screw terminals. is smooth enough. • Sealing materials may deteriorate when used outdoors or when • Check that OT has a sufficient margin. The actual OT should be exposed to cutting oil, solvents, or chemicals. Check this on actual rated OT × 0.7 to 1. equipment and, if deterioration is foreseen, consult your OMRON • Do not change the operating position by remodeling the actuator. representative in advance. • If the one-touch connector is to be mounted onto the switch body, Wiring lightly push up the fitting so that the switch body can then be When wiring screw terminals, M3-size round solderless terminals with inserted into the clamp. an insulation tube is recommended. The conductor size should be 2 0.75 mm and cable diameter should be 7 mm. (2) Lightly push up the filling on the left and right side alternately. Round solderless terminals (1) Insert the switch L dz dia.: 3.2 body D dia.: 1.9 l F B: 5.2 L: 16.4 F: 5.8 l: 8.0 (mm) B D dia. dz dia. Wiring Method • Be sure that the clamp is inserted to the full depth, because the Switch will not function properly if one of the clamps is improperly inserted. Confirm visually Round solderless terminal Switch body Clamp fitting • If the clamp is properly inserted up to the full depth, it will not slide out easily. Be sure to carefully confirm all the above items. 9 D4E-@N Tightening Torque A loose screw may result in a malfunction. Be sure to tighten each screw to the proper tightening torque as shown below. Appropriate No. Type tightening torque (1) Terminal screw (M3) 0.24 to 0.44 N·m (2) Switch mounting screw (M4) 1.18 to 1.37 N·m 10 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.12 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the D4E1G24N?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Basic / Snap Action Switches BASIC SWITCH A-20GV-C-K

product

Switch Limit N.O./N.C. SPDT Side Roller Lever Conduit 10A 600VAC 250VDC Rotary Screw Mount D4A-1101-...

product

Switch Limit N.O./N.C. SPDT Side Roller Lever Conduit 10A 600VAC 250VDC Rotary Screw Mount D4A1101NF

product

Switch Limit N.O./N.C. SPDT Side Roller Lever Conduit 10A 600VAC 250VDC Rotary Screw Mount D4A-1102-...

product

Switch Limit N.O./N.C. SPDT Side Roller Lever Conduit 10A 600VAC 250VDC Rotary Screw Mount D4A-1103-...

product

Switch Limit N.O./N.C. SPDT Side Roller Lever Conduit 10A 600VAC 250VDC Rotary Screw Mount D4A-1104-...