OMRON AUTOMATION D4N-9132
Specifications
Manufacturer
Omron Automation
Manufacturers Part #
D4N-9132
Industry Aliases
D4N-9132
Sub-Category
Limit Switches
Factory Pack Quantity
1
Datasheet
Extracted Text
Safety Limit Switch D4N CSM_D4N_DS_E_9_2 Note: Contact your sales representative for details on models Popular Safety Limit Switches with safety standard certification. Providing a Full Lineup Conforming to International Standards • Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and 3NC contact forms. (Slow-action models with MBB contacts are available.) • M12-connector models are also available, saving on labor and simplifying replacement. • Standardized gold-clad contacts provide high contact reliability. Can be used with both standard loads and microloads. • Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only). • Certified standards: UL, EN (TÜV), and CCC Be sure to read the “Safety Precautions” on page 17. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend 1-Conduit Models 2-Conduit Models D4N-@@@@ D4N-@@@@ 1 2 3 1 2 3 1. Conduit size 1. Conduit size 1: Pg13.5 6: G1/2 2: G1/2 8: M20 4: M20 9: M12 connector 2. Built-in Switch 2. Built-in Switch 1: 1NC/1NO (snap-action) 1: 1NC/1NO (snap-action) 2: 2NC (snap-action) 2: 2NC (snap-action) A: 1NC/1NO (slow-action) A: 1NC/1NO (slow-action) B: 2NC (slow-action) B: 2NC (slow-action) C: 2NC/1NO (slow-action) C: 2NC/1NO (slow-action) D: 3NC (slow-action) D: 3NC (slow-action) E: 1NC/1NO (MBB contact) (slow-action) E: 1NC/1NO (MBB contact) (slow-action) F: 2NC/1NO (MBB contact) (slow-action) F: 2NC/1NO (MBB contact) (slow-action) 3. Head and Actuator 3. Head and Actuator 20: Roller lever (resin lever, resin roller) 20: Roller lever (resin lever, resin roller) 22: Roller lever (metal lever, resin roller) 22: Roller lever (metal lever, resin roller) 25: Roller lever (metal lever, metal roller) 25: Roller lever (metal lever, metal roller) 26: Roller lever (metal lever, bearing roller) 26: Roller lever (metal lever, bearing roller) 2G: Adjustable roller lever, form lock (metal lever, resin roller) 2G: Adjustable roller lever, form lock (metal lever, resin roller) 2H: Adjustable roller lever, form lock (metal lever, rubber roller) 2H: Adjustable roller lever, form lock (metal lever, rubber roller) 31: Plunger 31: Plunger 32: Roller Plunger 32: Roller Plunger 62: One-way roller arm lever (horizontal) 62: One-way roller arm lever (horizontal) 72: One-way roller arm lever (vertical) 72: One-way roller arm lever (vertical) 80: Cat whisker 87: Plastic rod RE:Fork lever lock (right operation) LE: Fork lever lock (left operation) 1 D4N Ordering Information List of Models Consult with your OMRON representative when ordering any models that are not listed in this table. Switches with Two Contacts (with Direct Opening Mechanism) Built-in switch mechanism 1NC/1NO 2NC 1NC/1NO 2NC Actuator Conduit size (Snap-action) (Snap-action) (Slow-action) (Slow-action) Direct Direct Direct Direct Model Model Model Model opening opening opening opening Roller lever (resin Pg13.5 D4N-1120 D4N-1220 D4N-1A20 D4N-1B20 lever, resin roller) G1/2 D4N-2120 D4N-2220 D4N-2A20 D4N-2B20 1-conduit M20 D4N-4120 D4N-4220 D4N-4A20 D4N-4B20 M12 connector D4N-9120 D4N-9220 D4N-9A20 D4N-9B20 G1/2 D4N-6120 D4N-6220 D4N-6A20 D4N-6B20 2-conduit M20 D4N-8120 D4N-8220 D4N-8A20 D4N-8B20 Roller lever (metal Pg13.5 D4N-1122 D4N-1222 D4N-1A22 D4N-1B22 lever, resin roller) G1/2 D4N-2122 D4N-2222 D4N-2A22 D4N-2B22 1-conduit M20 D4N-4122 D4N-4222 D4N-4A22 D4N-4B22 M12 connector D4N-9122 D4N-9222 D4N-9A22 D4N-9B22 G1/2 D4N-6122 D4N-6222 D4N-6A22 D4N-6B22 2-conduit M20 D4N-8122 D4N-8222 D4N-8A22 D4N-8B22 Roller lever (metal Pg13.5 D4N-1125 D4N-1225 D4N-1A25 D4N-1B25 lever, metal roller) G1/2 D4N-2125 D4N-2225 D4N-2A25 D4N-2B25 1-conduit M20 D4N-4125 D4N-4225 D4N-4A25 D4N-4B25 M12 connector D4N-9125 D4N-9225 D4N-9A25 D4N-9B25 Roller lever (metal Pg13.5 D4N-1126 D4N-1226 D4N-1A26 D4N-1B26 lever, bearing roller) G1/2 D4N-2126 D4N-2226 D4N-2A26 D4N-2B26 1-conduit M20 D4N-4126 D4N-4226 D4N-4A26 D4N-4B26 M12 connector D4N-9126 D4N-9226 D4N-9A26 D4N-9B26 Adjustable roller Pg13.5 D4N-112G D4N-122G D4N-1A2G D4N-1B2G lever, form lock G1/2 D4N-212G D4N-222G D4N-2A2G D4N-2B2G 1-conduit (metal lever, resin M20 D4N-412G D4N-422G D4N-4A2G D4N-4B2G roller) M12 connector D4N-912G D4N-922G D4N-9A2G D4N-9B2G G1/2 D4N-612G D4N-622G D4N-6A2G D4N-6B2G 2-conduit M20 D4N-812G D4N-822G D4N-8A2G D4N-8B2G Adjustable roller Pg13.5 D4N-112H D4N-122H D4N-1A2H D4N-1B2H lever, form lock G1/2 D4N-212H D4N-222H D4N-2A2H D4N-2B2H (metal lever, rubber 1-conduit roller) M20 D4N-412H D4N-422H D4N-4A2H D4N-4B2H M12 connector D4N-912H D4N-922H D4N-9A2H D4N-9B2H G1/2 D4N-612H D4N-622H D4N-6A2H D4N-6B2H 2-conduit M20 D4N-812H D4N-822H D4N-8A2H D4N-8B2H Plunger Pg13.5 D4N-1131 D4N-1231 D4N-1A31 D4N-1B31 G1/2 D4N-2131 D4N-2231 D4N-2A31 D4N-2B31 1-conduit M20 D4N-4131 D4N-4231 D4N-4A31 D4N-4B31 M12 connector D4N-9131 D4N-9231 D4N-9A31 D4N-9B31 G1/2 D4N-6131 D4N-6231 D4N-6A31 D4N-6B31 2-conduit M20 D4N-8131 D4N-8231 D4N-8A31 D4N-8B31 Roller plunger Pg13.5 D4N-1132 D4N-1232 D4N-1A32 D4N-1B32 G1/2 D4N-2132 D4N-2232 D4N-2A32 D4N-2B32 1-conduit M20 D4N-4132 D4N-4232 D4N-4A32 D4N-4B32 M12 connector D4N-9132 D4N-9232 D4N-9A32 D4N-9B32 G1/2 D4N-6132 D4N-6232 D4N-6A32 D4N-6B32 2-conduit M20 D4N-8132 D4N-8232 D4N-8A32 D4N-8B32 One-way roller arm Pg13.5 D4N-1162 D4N-1262 D4N-1A62 D4N-1B62 lever (horizontal) G1/2 D4N-2162 D4N-2262 D4N-2A62 D4N-2B62 1-conduit M20 D4N-4162 D4N-4262 D4N-4A62 D4N-4B62 M12 connector D4N-9162 D4N-9262 D4N-9A62 D4N-9B62 G1/2 D4N-6162 D4N-6262 D4N-6A62 D4N-6B62 2-conduit M20 D4N-8162 D4N-8262 D4N-8A62 D4N-8B62 One-way roller arm Pg13.5 D4N-1172 D4N-1272 D4N-1A72 D4N-1B72 lever (vertical) G1/2 D4N-2172 D4N-2272 D4N-2A72 D4N-2B72 1-conduit M20 D4N-4172 D4N-4272 D4N-4A72 D4N-4B72 M12 connector D4N-9172 D4N-9272 D4N-9A72 D4N-9B72 G1/2 D4N-6172 D4N-6272 D4N-6A72 D4N-6B72 2-conduit M20 D4N-8172 D4N-8272 D4N-8A72 D4N-8B72 2 D4N Switches with Three Contacts and MBB Contacts (with Direct Opening Mechanism) Built-in switch mechanism 2NC/1NO 3NC 1NC/1NO MBB 2NC/1NO MBB Actuator Conduit size (Slow-action) (Slow-action) (Slow-action) (Slow-action) Direct Direct Direct Direct Model Model Model Model opening opening opening opening Roller lever (resin Pg13.5 D4N-1C20 D4N-1D20 D4N-1E20 D4N-1F20 lever, resin roller) G1/2 D4N-2C20 D4N-2D20 D4N-2E20 D4N-2F20 1-conduit M20 D4N-4C20 D4N-4D20 D4N-4E20 D4N-4F20 M12 connector --- --- D4N-9E20 --- G1/2 D4N-6C20 D4N-6D20 D4N-6E20 D4N-6F20 2-conduit M20 D4N-8C20 D4N-8D20 D4N-8E20 D4N-8F20 Roller lever (metal Pg13.5 D4N-1C22 D4N-1D22 D4N-1E22 D4N-1F22 lever, resin roller) G1/2 D4N-2C22 D4N-2D22 D4N-2E22 D4N-2F22 1-conduit M20 D4N-4C22 D4N-4D22 D4N-4E22 D4N-4F22 M12 connector --- --- D4N-9E22 --- G1/2 D4N-6C22 D4N-6D22 D4N-6E22 D4N-6F22 2-conduit M20 D4N-8C22 D4N-8D22 D4N-8E22 D4N-8F22 Roller lever (metal Pg13.5 D4N-1C25 D4N-1D25 D4N-1E25 D4N-1F25 lever, metal roller) G1/2 D4N-2C25 D4N-2D25 D4N-2E25 D4N-2F25 1-conduit M20 D4N-4C25 D4N-4D25 D4N-4E25 D4N-4F25 M12 connector --- --- D4N-9E25 --- Roller lever (metal Pg13.5 D4N-1C26 D4N-1D26 D4N-1E26 D4N-1F26 lever, bearing roller) G1/2 D4N-2C26 D4N-2D26 D4N-2E26 D4N-2F26 1-conduit M20 D4N-4C26 D4N-4D26 D4N-4E26 D4N-4F26 M12 connector --- --- D4N-9E26 --- Adjustable roller Pg13.5 D4N-1C2G D4N-1D2G D4N-1E2G D4N-1F2G lever, form lock G1/2 D4N-2C2G D4N-2D2G D4N-2E2G D4N-2F2G 1-conduit (metal lever, resin M20 D4N-4C2G D4N-4D2G D4N-4E2G D4N-4F2G roller) M12 connector --- --- D4N-9E2G --- G1/2 D4N-6C2G D4N-6D2G D4N-6E2G D4N-6F2G 2-conduit M20 D4N-8C2G D4N-8D2G D4N-8E2G D4N-8F2G Adjustable roller Pg13.5 D4N-1C2H D4N-1D2H D4N-1E2H D4N-1F2H lever, form lock G1/2 D4N-2C2H D4N-2D2H D4N-2E2H D4N-2F2H (metal lever, rubber 1-conduit roller) M20 D4N-4C2H D4N-4D2H D4N-4E2H D4N-4F2H M12 connector --- --- D4N-9E2H --- G1/2 D4N-6C2H D4N-6D2H D4N-6E2H D4N-6F2H 2-conduit M20 D4N-8C2H D4N-8D2H D4N-8E2H D4N-8F2H Plunger Pg13.5 D4N-1C31 D4N-1D31 D4N-1E31 D4N-1F31 G1/2 D4N-2C31 D4N-2D31 D4N-2E31 D4N-2F31 1-conduit M20 D4N-4C31 D4N-4D31 D4N-4E31 D4N-4F31 M12 connector --- --- D4N-9E31 --- G1/2 D4N-6C31 D4N-6D31 D4N-6E31 D4N-6F31 2-conduit M20 D4N-8C31 D4N-8D31 D4N-8E31 D4N-8F31 Roller plunger Pg13.5 D4N-1C32 D4N-1D32 D4N-1E32 D4N-1F32 G1/2 D4N-2C32 D4N-2D32 D4N-2E32 D4N-2F32 1-conduit M20 D4N-4C32 D4N-4D32 D4N-4E32 D4N-4F32 M12 connector --- --- D4N-9E32 --- G1/2 D4N-6C32 D4N-6D32 D4N-6E32 D4N-6F32 2-conduit M20 D4N-8C32 D4N-8D32 D4N-8E32 D4N-8F32 One-way roller arm Pg13.5 D4N-1C62 D4N-1D62 D4N-1E62 D4N-1F62 lever (horizontal) G1/2 D4N-2C62 D4N-2D62 D4N-2E62 D4N-2F62 1-conduit M20 D4N-4C62 D4N-4D62 D4N-4E62 D4N-4F62 M12 connector --- --- D4N-9E62 --- G1/2 D4N-6C62 D4N-6D62 D4N-6E62 D4N-6F62 2-conduit M20 D4N-8C62 D4N-8D62 D4N-8E62 D4N-8F62 One-way roller arm Pg13.5 D4N-1C72 D4N-1D72 D4N-1E72 D4N-1F72 lever (vertical) G1/2 D4N-2C72 D4N-2D72 D4N-2E72 D4N-2F72 1-conduit M20 D4N-4C72 D4N-4D72 D4N-4E72 D4N-4F72 M12 connector --- --- D4N-9E72 --- G1/2 D4N-6C72 D4N-6D72 D4N-6E72 D4N-6F72 2-conduit M20 D4N-8C72 D4N-8D72 D4N-8E72 D4N-8F72 3 D4N General-purpose Switches with Two Contacts Built-in switch mechanism 1NC/1NO 2NC 1NC/1NO 2NC Actuator Conduit size (Snap-action) (Snap-action) (Slow-action) (Slow-action) Direct Direct Direct Direct Model Model Model Model opening opening opening opening Fork lever lock G1/2 D4N-2ARE D4N-2BRE (right operation) M20 D4N-4ARE D4N-4BRE --- --- --- Fork lever lock (left G1/2 D4N-2ALE D4N-2BLE operation) M20 D4N-4ALE D4N-4BLE 1-conduit --- Cat whisker G1/2 D4N-2180 D4N-2280 D4N-2B80 M20 D4N-4180 D4N-4280 D4N-4B80 --- --- --- Plastic rod G1/2 D4N-2187 D4N-2287 D4N-2B87 M20 D4N-4187 D4N-4287 D4N-4B87 Note: Mechanically speaking, these models are general-purpose switches with no direct opening mechanism. General-purpose Switches with Three Contacts and MBB Contacts Built-in switch mechanism 2NC/1NO 3NC 1NC/1NO MBB 2NC/1NO MBB Actuator Conduit size (Slow-action) (Slow-action) (Slow-action) (Slow-action) Direct Direct Direct Direct Model Model Model Model opening opening opening opening Fork lever lock G1/2 D4N-2CRE D4N-2DRE D4N-2ERE D4N-2FRE (right operation) M20 D4N-4CRE D4N-4DRE D4N-4ERE D4N-4FRE --- --- --- Fork lever lock G1/2 D4N-2CLE D4N-2DLE D4N-2ELE D4N-2FLE (left operation) M20 D4N-4CLE D4N-4DLE D4N-4ELE D4N-4FLE 1-conduit --- Cat whisker G1/2 D4N-2D80 M20 D4N-4D80 --- --- --- Plastic rod G1/2 D4N-2D87 M20 D4N-4D87 Note: Mechanically speaking, these models are general-purpose switches with no direct opening mechanism. 4 D4N Specifications Standards and EC Directives Certified Standard Ratings Conforms to the following EC Directives: TÜV (EN60947-5-1), CCC (GB14048.5) • Machinery Directive Utilization AC-15 DC-13 • Low Voltage Directive Item category • EN50047 Rated operating current (Ie) 3 A 0.27 A • EN60204-1 Rated operating voltage (Ue) 240 V 250 V • EN ISO 14119 • GS-ET-15 Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch. Certified Standards Certification Standard File No. UL/CSA (UL508, CSA C22.2 No. 14) body A300 EN60947-5-1 TÜV SÜD *1 (certified direct opening) Current (A) Volt-amperes (VA) Rated Carry current UL *2 UL508, CSA C22.2 No.14 E76675 voltage Make Break Make Break CQC (CCC) *3 GB14048.5 2004010305105973 120 VAC 60 6 10 A 7,200 720 *1. Consult your OMRON representative for details. 240 VAC 30 3 *2. Certification for CSA C22.2 No. 14 is authorized by the UL mark. *3. Ask your OMRON representative for information on certified Q300 models. Current (A) Volt-amperes (VA) Rated Carry current voltage Make Break Make Break 125 VDC 0.55 0.55 2.5 A 69 69 250 VDC 0.27 0.27 5 D4N Characteristics Degree of protection *1 IP67 (EN60947-5-1) Mechanical 15,000,000 operations min. *5 Durability *2 500,000 operations min. (3 A resistive load at 250 VAC) *3 Electrical 300,000 operations min. (10 A resistive load at 250 VAC) Operating speed 1 to 500 mm/s (D4N-1120) Operating frequency 30 operations/minute max. Contact resistance 25 mΩ max. Minimum applicable load *4 1 mA resistive load at 5 VDC (N-level reference value) Rated insulation voltage (Ui) 300 V Rated frequency 50/60 Hz Protection against electric shock Class II (double insulation) Pollution degree (operating environment) 3 (EN60947-5-1) Between terminals of 2.5 kV same polarity Impulse withstand Between terminals of 4 kV voltage different polarity (EN60947-5-1) Between each terminal and non-current carrying 6 kV metallic parts Insulation resistance 100 MΩ min. Snap-action: 2 × 0.5 mm min. Contact gap Slow-action: 2 × 2 mm min. Vibration resistance Malfunction 10 to 55 Hz, 0.75 mm single amplitude 2 Destruction 1,000 m/s min. Shock resistance 2 Malfunction 300 m/s min. Conditional short-circuit current 100 A (EN60947-5-1) Conventional free air thermal current (Ith) 10 A (EN60947-5-1) Ambient operating temperature −30 to 70°C (with no icing) Ambient operating humidity 95% max. Approx. 82 g (D4N-1120) Weight Approx. 99 g (D4N-6120) Note: 1. The above values are initial values. 2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in roughening of the contact surface and contact reliability may be lost. *1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4N in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Otherwise, accelerated wear, Switch damage or malfunctioning may occur. *2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative. *3. Do not pass the 3 A, 250 VAC load through more than 2 circuits. *4. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand. *5. The mechanical durability of fork lever lock models is 10,000,000 operations min. 6 D4N Structure and Nomenclature Structure Safety-oriented Lever Setting (Form-lock construction) Head Grooves which engage the lever are cut in the lever and The direction of the switch head can be varied to any of rotary shaft to prevent the lever from slipping against the the four directions. (Roller plunger models can be rotary shaft. mounted in either of two directions at a 90° angle.) There are resin-lever and metal-lever types. Conduit Opening A wide variety of conduits is available. Built-in Switch The built-in switch has a direct opening mechanism Size Box 1-conduit 2-conduit that forcibly separates the NC contact even when Pg13.5 Yes --- there is contact deposit. G1/2 Yes Yes Cover M20 Yes Yes The cover, with a hinge on its lower part, can M12 connector be opened by removing the screw of the Yes --- cover, which ensures ease of maintenance Note: M12 connector types are not available for and wiring. Switches with three contacts. Direct Opening Mechanism 1NC/1NO Contact (Slow-action) 2NC Contact (Slow-action) Fixed contact (NC) Fixed contact (NC) Movable contact Contact spring Contact spring Movable contact Plunger Fixed contact (NO) Plunger Return spring Return spring Conforms to EN60947-5-1 Direct Opening Operation Conforms to EN60947-5-1 Direct Opening Operation (Only the NC contact side has a direct opening (Both NC contacts have a direct opening mechanism.) mechanism.) When contact welding occurs, the contacts are When contact welding occurs, the contacts are separated from each other by the plunger being separated from each other by the plunger being pushed in. pushed in. 7 D4N Contact Form Model Contact Contact form Operating pattern Remarks Only NC contacts 31-32 have a Zb certified direct opening 13 14 13-14 1NC/1NO ON mechanism. D4N-@1@ 31-32 (Snap-action) Stroke 31 32 The terminals 13-14 and 31-32 can be used as unlike poles. Only NC contacts 11-12 and Zb 31-32 have a certified direct 11-12 ON 11 12 opening mechanism. D4N-@2@ 2NC (Snap-action) 31-32 31 32 Stroke The terminals 11-12 and 31-32 can be used as unlike poles. Only NC contacts 11-12 have a Zb certified direct opening 11-12 1NC/1NO 11 12 ON mechanism. D4N-@A@ 33-34 (Slow-action) 33 34 Stroke The terminals 11-12 and 33-34 can be used as unlike poles. Only NC contacts 11-12 and Zb 31-32 have a certified direct 11-12 ON 11 12 opening mechanism. D4N-@B@ 2NC (Slow-action) 31-32 31 32 Stroke The terminals 11-12 and 31-32 can be used as unlike poles. Only NC contacts 11-12 and Zb 21-22 have a certified direct 11-12 11 12 opening mechanism. 2NC/1NO 21-22 ON D4N-@C@ 21 22 (Slow-action) 33-34 The terminals 11-12, 21-22, and Stroke 33 34 33-34 can be used as unlike poles. Only NC contacts 11-12, 21-22, Zb and 31-32 have a certified direct 11-12 11 12 opening mechanism. 21-22 ON D4N-@D@ 3NC (Slow-action) 21 22 31-32 The terminals 11-12, 21-22, and Stroke 31-32 can be used as unlike 31 32 poles. Only NC contacts 11-12 have a Zb certified direct opening 11-12 1NC/1NO MBB * 11 12 ON mechanism. D4N-@E@ 33-34 (Slow-action) 33 34 Stroke The terminals 11-12 and 33-34 can be used as unlike poles. Zb Only NC contacts 11-12 and 11-12 21-22 have a certified direct 11 12 2NC/1NO MBB * 21-22 ON opening mechanism. D4N-@F@ 21 22 (Slow-action) 33-34 The terminals 11-12, 21-22 and Stroke 33 34 33-34 can be used as unlike poles. Note: The terminal numbers are according to EN 50013 and the contact symbols are according to EN 60947-5-1. * MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally open contact (NO) closes. 8 D4N Dimensions and Operating Characteristics (Unit: mm) Switches 1-conduit Models Roller Lever (Resin Lever, Resin Roller) Roller Lever (Metal Lever, Resin Roller) D4N-1@20 D4N-2@20 D4N-1@22 D4N-2@22 D4N-4@20 D4N-9@20 * 47±1 D4N-4@22 D4N-9@22 * 45±1 ±1 17.5 dia. × 6.8 40 1 39.5± 17.5 dia. × 6.8 resin roller (27) resin roller (31) ±0.2 11 0.2 26R 11± 26R Resin lever Metal lever 20.5 × 20.5 20.5 × 20.5 27.5 27.5 18 18 9±0.2 9±0.2 21.5 21.5 2.5 ±0.1 2.5 20 0.1 20± ±0.2 47 22±0.1 0.2 47± 22±0.1 55 2.15±0.05R 55 2.15±0.05R mounting holes mounting holes +0.15 +0.15 Two, 4 dia. holes Two, 4 0 dia. holes ±0.2 0 22 14.2 0.2 Conduit cap 22± 14.2 30 Conduit cap Depth: 5 Depth: 5 30 31 max. 31 max. Roller Lever (Metal Lever, Metal Roller) Roller Lever (Metal Lever, Bearing Roller) D4N-1@25 D4N-2@25 D4N-1@26 D4N-2@26 D4N-4@25 D4N-9@25 * D4N-4@26 D4N-9@26 * 43.6±1 45±1 1 17.5 dia. × 7 39± 17 dia. × 6 1 sintered stainless 39.5± (31.5) Bearing roller steel roller (31) 0.2 11± 26R 0.2 11± Metal lever 26R Metal lever 20.5 × 20.5 20.5 × 20.5 27.5 18 27.5 9±0.2 18 9±0.2 21.5 2.5 20±0.1 21.5 2.5 20±0.1 0.2 0.1 47± 22± 55 2.15±0.05R 0.2 0.1 47± 22± 55 mounting holes 2.15±0.05R mounting holes +0.15 Two, 4 0 dia. holes 0.2 14.2 22± +0.15 Conduit cap Two, 4 dia. holes 30 Depth: 5 0.2 0 22± 14.2 31 max. Conduit cap 30 Depth: 5 31 max. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. * Refer to page 12 for details on M12 connectors. Slow-action (1NC/1NO) (2NC/1NO) Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC) Model D4N-@A20 D4N-@A22 D4N-@A25 D4N-@A26 D4N-@C20 D4N-@C22 D4N-@C25 D4N-@C26 Model D4N-@120 D4N-@122 D4N-@125 D4N-@126 D4N-@E20 D4N-@E22 D4N-@E25 D4N-@E26 D4N-@220 D4N-@222 D4N-@225 D4N-@226 Operating characteristics D4N-@F20 D4N-@F22 D4N-@F25 D4N-@F26 D4N-@B20 D4N-@B22 D4N-@B25 D4N-@B26 Operating force OF max. 5.0 N Operating characteristics D4N-@D20 D4N-@D22 D4N-@D25 D4N-@D26 Release force RF min. 0.5 N Operating force OF max. 5.0 N PT (NC) 18° to 27° Release force RF min. 0.5 N PT (NO) (44°) Pretravel PT 18° to 27° *1 Overtravel OT min. 40° PT (NC) 27.5° to 36.5° Movement differential MD max. 14° *2 *1 PT (NO) (18°) Operating position OP --- *1, *2 Total travel TT *2 (80°) Overtravel OT min. 40° Direct opening travel DOT min. 50° Operating position OP --- *3 Total travel TT *1 (80°) Direct opening force DOF min. 20 N DOT min. 50° *3 Direct opening travel *3 Note: Variation occurs in the simultaneity of contact opening/closing DOF min. 20 N Direct opening force operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact *3 operation. *1. Reference values. *1. Only for snap-action models. *2. Only for MBB models. (D4N-@E@@ or D4N-@F@@) *2. Reference value. *3. For safe use, always make sure that the minimum values or greater *3. For safe use, always make sure that the minimum values or greater are provided. are provided. 9 D4N 1-conduit Models Plunger Roller Plunger D4N-1@31 D4N-2@31 D4N-1@32 D4N-2@32 D4N-4@31 D4N-9@31 * D4N-4@32 D4N-9@32 * ±0.1 25 (31.5) Two, 3±0.05 dia. 21.5 (31.5) holes 20.5 × 20.5 ±0.2 11 21.5 9.5 dia. × 5 12 dia. ±0.2 11 resin roller 6-dia. resin plunger OP 25.2 OP ±0.2 9 ±0.2 9 2.5 2.5 ±0.1 20 ±0.1 20 ±0.2 ±0.1 47 22 ±0.2 ±0.1 47 22 55 55 2.15±0.05R 2.15±0.05R mounting holes mounting holes ±0.2 22 14.2 +0.15 ±0.2 14.2 22 +0.15 Conduit cap Two, 4 dia. holes 0 Conduit cap Two, 4 dia. holes 30 30 0 31 max. 31 max. Depth: 5 Depth: 5 One-way Roller Arm Lever One-way Roller Arm Lever (Horizontal) (Vertical) D4N-1@62 D4N-2@62 D4N-1@72 D4N-2@72 D4N-4@62 D4N-9@62 * D4N-4@72 D4N-9@72 * (31.5) 21.5 Operating direction OP 12 dia. × 5 (31.5) ±0.2 11 12 resin roller ±0.2 14.8 11 21.5 11±0.2 ±0.2 11 12.5 dia. × 5 19R 14.7 resin roller 10.2 13.5 19.5±0.2 20R 10.2 ±0.2 9 OP 23.3 ±0.2 19.5 2.15±0.05R ±0.2 2.5 9 20±0.1 mounting holes ±0.2 ±0.1 47 22 2.5 55 ±0.1 20 Operating ±0.2 22±0.1 47 direction 55 2.15±0.05R mounting holes +0.15 22±0.2 14.2 Two, 4 dia. holes Conduit cap 0 30 31 max. Depth: 5 ±0.2 22 14.2 +0.15 Conduit cap Two, 4 dia. holes 0 30 31 max. Depth: 5 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. * Refer to page 12 for details on M12 connectors. 10 D4N Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC) Model D4N-@131 D4N-@132 D4N-@162 D4N-@172 D4N-@231 D4N-@232 D4N-@262 D4N-@272 D4N-@B31 D4N-@B32 D4N-@B62 D4N-@B72 Operating characteristics D4N-@D31 D4N-@D32 D4N-@D62 D4N-@D72 Operating force OF max. 6.5 N 6.5 N 5.0 N 5.0 N Note: Variation occurs in the simultaneity Release force RF min. 1.5 N 1.5 N 0.8 N 0.8 N of contact opening/closing Pretravel PT max. 2 mm 2 mm 4 mm 4 mm operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact Overtravel OT min. 4 mm 4 mm 5 mm 5 mm operation. Movement differential MD max. *1 1 mm 1 mm 1.5 mm 1.5 mm *1. Only for snap-action models. Operating position OP 18.2 ±0.5 mm 28.6 ±0.8 mm 37 ±0.8 mm 27 ±0.8 mm *2. Reference value. *3. For safe use, always make sure that Total travel TT *2 (6 mm) (6 mm) (9 mm) (9 mm) the minimum values or greater are Direct opening travel DOT min. *3 3.2 mm 3.2 mm 5.8 mm 4.8 mm provided. Direct opening force DOF min. *3 20 N 20 N 20 N 20 N Slow-action (1NC/1NO) (2NC/1NO) Model D4N-@A31 D4N-@A32 D4N-@A62 D4N-@A72 D4N-@C31 D4N-@C32 D4N-@C62 D4N-@C72 D4N-@E31 D4N-@E32 D4N-@E62 D4N-@E72 Operating characteristics D4N-@F31 D4N-@F32 D4N-@F62 D4N-@F72 Operating force OF max. 6.5 N 6.5 N 5.0 N 5.0 N Release force RF min. 1.5 N 1.5 N 0.8 N 0.8 N Pretravel PT max. (NC) 2 mm 2 mm 4 mm 4 mm PT (NO) *1 (2.9 mm) (2.9 mm) (5.2 mm) (4.3 mm) PT max. (NC) *2 2.8 mm 2.8 mm 4 mm 4 mm PT (NO) *1, *2 (1 mm) (1 mm) (1.5 mm) (1.5 mm) Overtravel OT min. 4 mm 4 mm 5 mm 5 mm *1. Reference values. Operating position OP 18.2 ±0.5 mm 28.6 ±0.8 mm 37 ±0.8 mm 27 ±0.8 mm *2. Only for MBB models. (D4N-@E@@ or OP *2 17.4 ±0.5 mm 28 ±0.8 mm 36 ±0.8 mm 26.1 ±0.8 mm D4N-@F@@) Total travel TT *1 (6 mm) (6 mm) (9 mm) (9 mm) *3. For safe use, always make sure that the minimum values or greater are Direct opening travel DOT min. *3 3.2 mm 3.2 mm 5.8 mm 4.8 mm provided. Direct opening force DOF min. *3 20 N 20 N 20 N 20 N 11 D4N 1-conduit Models Adjustable Roller Lever, Form Lock Adjustable Roller Lever, Form Lock (with Metal Lever, Resin Roller) (with Metal Lever, Rubber Roller) D4N-1@2G D4N-2@2G D4N-1@2H D4N-2@2H ±1 48.2 1 D4N-4@2G D4N-9@2G * 45± D4N-4@2H D4N-9@2H * 41.3±1 50 dia. × 8 1 39.5± 17.5 dia. × 6.8 (29.2) rubber roller resin roller (31) Bearing 0.2 11± 20 to 66R ±0.2 11 20.5 × 20.5 32 to 66R 20.5 × 20.5 27.5 18 0.2 9± 27.5 18 21.5 2.5 9±0.2 21.5 0.2 47± 2.5 55 2.15±0.05R 0.1 20± 47±0.2 mounting holes 0.1 2.15±0.05R 22± 55 ±0.1 20 mounting holes ±0.1 22 Stainless steel 0.2 14.2 lever 22± +0.15 Conduit cap Two, 4 dia. holes 30 0 31 max. Depth: 5 ±0.2 22 14.2 Conduit cap 30 31 max. +0.15 Two, 4 0 dia. holes Depth: 5 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. * Refer to following diagrams for details on M12 connectors. Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC) Model D4N-@12H D4N-@12G D4N-@22H D4N-@22G D4N-@B2H D4N-@B2G D4N-@D2H D4N-@D2G Operating characteristics *1 Operating force OF max. 4.5 N Note: Variation occurs in the simultaneity of contact Release force RF min. 0.4 N opening/closing operations of 2NC, 2NC/1NO, and Pretravel PT 18° to 27° 3NC contacts. Check contact operation. Overtravel OT min. 40° *1. The operating characteristics of these Switches were measured with the roller lever set at 32 mm. Movement differential MD max. *2 14° *2. Only for snap-action models. Operating position OP --- *3. Reference value. Total travel TT *3 (80°) *4. For safe use, always make sure that the minimum values Direct opening travel DOT min. *4 50° or greater are provided. Direct opening force DOF min. *4 20 N Slow-action (1NC/1NO) (2NC/1NO) Model D4N-@A2H D4N-@A2G D4N-@C2H D4N-@C2G D4N-@E2H D4N-@E2G D4N-@F2H D4N-@F2G Operating characteristics *1 Operating force OF max. 4.5 N Release force RF min. 0.4 N Pretravel PT (NC) 18° to 27° PT (NO) *2 (44°) PT (NC) *3 27.5° to 36.5° PT (NO) *2, *3 (18°) *1. The operating characteristics of these Switches were Overtravel OT min. 40° measured with the roller lever set at 32 mm. Operating position OP --- *2. Reference values. Total travel TT *2 (80°) *3. Only for MBB models. (D4N-@E@@ or D4N-@F@@) *4. For safe use, always make sure that the minimum Direct opening travel DOT min. 50° values or greater are provided. Direct opening force DOF min. *4 20 N 1-conduit M12 Connector D4N-9@@@ (14) M12 × 1 14.2 30 12 D4N 1-conduit Models Fork Lever Lock Fork Lever Lock (Right Operation) *2 (Left Operation) *2 D4N-2@RE D4N-2@LE D4N-4@RE D4N-4@LE 47 max. Two, 17.5 dia. 47 max. 1 39.3± Two, 17.5 dia. × × 8 rubber 39.3±1 (27.2) 8 rubber rollers rollers (27.2) 90° 0.2 11± 90° 26R 11±0.2 26R 20.5 × 20.5 20.5 × 20.5 27.5 18 27.5 0.2 9± 18 9±0.2 21.5 2.5 21.5 0.1 20± 2.5 0.1 20± 0.1 0.2 22± 47± 55 2.15±0.05R 47±0.2 0.1 22± 55 2.15±0.05R mounting holes mounting holes +0.15 14.2 0.2 22± Two, 4 0 dia. holes Conduit cap 0.2 30 22± 14.2 +0.15 31 max. Two, 4 dia. holes Depth: 5 Conduit cap 0 30 31 max. Depth: 5 Cat Whisker *2 Plastic Rod *2 D4N-2@80 D4N-2@87 D4N-4@80 D4N-4@87 PT 1.2-dia. 38 PT stainless Resin rod *1 steel wire 20.5 × 42 *1 20.5 115 21.5 20.5 × 20.5 143.1 16.6 dia. 21.5 (50.1) Sealing cap 11±0.2 16.6 dia. 0.2 ±0.2 Sealing cap 11± 12 ±0.2 9 0.2 9± 2.5 20±0.1 2.5 ±0.2 ±0.1 47 22 0.1 20± 55 2.15±0.05R 0.2 0.1 47± 22± mounting holes 55 2.15±0.05R mounting holes 22±0.2 14.2 Conduit cap 30 31 max. 0.2 22± 14.2 +0.15 (31.5) Two, 4 dia. holes Conduit cap 30 0 31 max. Depth: 5 +0.15 (31.5) Two, 4 dia. holes 0 Depth: 5 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. *1. The usable range for stainless steel wires and resin rods is 35 mm max. from the end with a total travel of 70 mm max. *2. In terms of construction, the Switch is a General-purpose Limit Switch rather than a Safety Limit Switch. Slow-action (1NC/1NO) (2NC/1NO) (2NC) (3NC) Note: Variation occurs in the simultaneity of contact opening/closing Model operations of 2NC, 2NC/1NO, and 3NC contacts. Check D4N-@@RE D4N-@@LE Operating characteristics contact operation. Force necessary to reverse the direction of the lever: 6.4 N 6.4 N max. Movement until the lever 55 ±10° 55 ±10° reverses Movement until switch (6.5°) (6.5°) operation (NC) (MBB: 10°) (MBB: 10°) Movement until switch (18.5°) (18.5°) operation (NO) (MBB: 5°) (MBB: 5°) Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC) Model D4N-@@80 D4N-@@87 Operating characteristics Operating force OF max. 1.5 N 1.5 N Pretravel PT max. 15° 15° 13 D4N 2-conduit Models Roller Lever (Metal Lever, Resin Roller) Roller Lever (Resin Lever, Resin Roller) ±1 47 D4N-6@22 D4N-6@20 ±1 40 17.5 dia. × 6.8 45±1 D4N-8@22 D4N-8@20 resin roller (27) ±1 39.5 17.5 dia. × 6.8 ±0.2 11 (31) resin roller 26R Resin lever 11±0.2 20.5 × 20.5 26R Metal lever 20.5 × 20.5 5.4 2.5 27.5 18 ±0.2 21.5 9 5.4 2.5 27.5 18 ±0.1 20 ±0.2 21.5 9 20.5 ±0.2 39 ±0.1 22 2.15±0.05R ±0.1 25 dia. ±0.1 40 20 20.5 mounting 47 ±0.2 39 22±0.1 holes ±0.1 25 dia. 40 47 Cap Conduit ±0.1 42 2.15±0.05R cap Cap mounting 42±0.2 (3) holes 14.2 56 max. 30 Conduit cap 42±0.2 (3) 14.2 +0.15 56 max. 30 Two, 4 dia. holes 0 +0.15 Depth: 5 Two, 4 dia. holes 0 Depth: 5 Plunger Roller Plunger 25±0.1 D4N-6@31 D4N-6@32 (31.5) D4N-8@31 D4N-8@32 21.5 20.5 × 20.5 ±0.2 11 (31.5) Two, 3±0.05 9.5 dia. × 5 21.5 dia. holes resin roller 12 dia. ±0.2 11 6-dia. resin plunger OP 2.5 25.2 ±0.2 9 5.4 2.5 OP 5.4 20±0.1 9±0.2 20.5 ±0.2 39 ±0.1 22 2.15±0.05R ±0.1 25 dia. ±0.1 40 20 20.5 47 39±0.2 ±0.1 mounting 42±0.1 22 2.15±0.05R 25 dia. 40±0.1 holes 47 Cap mounting ±0.1 42 holes Cap Conduit cap ±0.2 42 (3) 14.2 56 max. 30 Conduit cap ±0.2 42 (3) 14.2 +0.15 Two, 4 dia. holes 0 56 max. 30 Depth: 5 +0.15 Two, 4 dia. holes 0 Depth: 5 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Snap-action (1NC/1NO) (2NC), Slow-action (2NC) Slow-action (1NC/1NO) (2NC/1NO) (3NC) Model D4N-@A20 D4N-@A22 D4N-@A31 D4N-@A32 D4N-@C20 D4N-@C22 D4N-@C31 D4N-@C32 Model D4N-@120 D4N-@122 D4N-@131 D4N-@132 D4N-@E20 D4N-@E22 D4N-@E31 D4N-@E32 D4N-@220 D4N-@222 D4N-@231 D4N-@232 Operating characteristics D4N-@F20 D4N-@F22 D4N-@F31 D4N-@F32 D4N-@B20 D4N-@B22 D4N-@B31 D4N-@B32 Operating force OF max. 5 N 5 N 6.5 N 6.5 N Operating characteristics D4N-@D20 D4N-@D22 D4N-@D31 D4N-@D32 Release force RF min. 0.5 N 0.5 N 1.5 N 1.5 N Operating force OF max. 5 N 5 N 6.5 N 6.5 N Pretravel PT (NC) 18° to 27° 18° to 27° 2 mm 2 mm Release force RF min. 0.5 N 0.5 N 1.5 N 1.5 N PT (NO) (44°)(44°) (2.9 mm) (2.9 mm) Pretravel PT 18° to 27° 18° to 27° 2 mm 2 mm *1 Overtravel OT min. 40° 40° 4 mm 4 mm PT (NC) 27.5° to 27.5° to 2.8 mm 2.8 mm Movement differential *2 36.5° 36.5° MD max. 14° 14° 1 mm 1 mm PT (NO) (18°)(18°) (1 mm) (1 mm) *1 *1, *2 18 28.2 Operating position OP --- --- Overtravel OT min. 40° 40° 4 mm 4 mm ±0.5 mm ±0.8 mm 18 28.2 Total travel TT *2 (80°)(80°) (6 mm) (6 mm) Operating position OP --- --- ±0.5 mm ±0.8 mm Direct opening travel 17.4 28 DOT min. 50° 50° 3.2 mm 3.2 mm OP *2 --- --- ±0.5 mm ±0.8 mm *3 Total travel TT *1 (80°)(80°) (6 mm) (6 mm) Direct opening force Direct opening travel DOF min. 20 N 20 N 20 N 20 N DOT min. 50° 50° 3.2 mm 3.2 mm *3 *3 Note: Variation occurs in the simultaneity of contact opening/closing Direct opening force operations of 2NC, 2NC/1NO, and 3NC contacts. Check DOF min. 20 N 20 N 20 N 20 N contact operation. *3 *1. Only for snap-action models. *1. Reference values. *2. Reference value. *2. Only for MBB models. (D4N-@E@@ or D4N-@F@@) *3. For safe use, always make sure that the minimum values or *3. For safe use, always make sure that the minimum values or greater are provided. greater are provided. 14 ±0.1 42 D4N 2-conduit Models One-way Roller Arm Lever One-way Roller Arm Lever Operating direction (Vertical) (Horizontal) (31.5) 14.8 21.5 D4N-6@72 D4N-6@62 (31.5) ±0.2 11 12 dia. x 5 D4N-8@72 D4N-8@62 11±0.2 21.5 OP resin roller ±0.2 11 12 12 dia. × 5 11±0.2 resin roller 13.5 20R 10.2 OP 23.3 5.4 2.5 19R 14.7 ±0.2 19.5 ±0.2 21.5 10.2 9 5.4 2.5 19.5±0.2 ±0.1 20 20.5 ±0.2 21.5 9 2.15±0.05R 39±0.2 22±0.1 mounting holes ±0.1 25 dia. 40 ±0.1 47 20 20.5 ±0.1 ±0.2 42 39 ±0.1 22 Cap ±0.1 25 dia. 40 47 Conduit cap 42±0.1 2.15±0.05R Cap 42±0.2 (3) mounting 14.2 56 max. 30 holes Operating 42±0.2 (3) Conduit cap +0.15 14.2 Two, 4 dia. holes direction 0 56 max. 30 Depth: 5 +0.15 Two, 4 dia. holes 0 Depth: 5 Adjustable Roller Lever, Form Lock 48.2±1 Adjustable Roller Lever, Form Lock ±1 (with Metal Lever, Rubber Roller) 41.3±1 45 (with Metal Lever, Resin Roller) ±1 (29.2) 39.5 D4N-6@2H 50 dia. × 8 D4N-6@2G 17.5 dia. × 6.8 (31) rubber roller Bearing D4N-8@2H resin roller D4N-8@2G 11±0.2 Resin lever 20 to 66R 11±0.2 2.15±0.05R 20.5 × 20.5 32 to 66R mounting holes 2.15±0.05R Stainless 20.5 × 20.5 mounting holes 5.4 2.5 27.5 steel lever 18 9±0.2 21.5 5.4 2.5 27.5 18 9±0.2 21.5 20.5 ±0.1 39±0.2 20 22±0.1 25 dia. 20.5 ±0.1 47 ±0.1 39±0.2 40 20 ±0.1 22±0.1 42 25 dia. Cap ±0.1 47 40 ±0.1 42 Cap Conduit cap ±0.2 42 (3) 14.2 Conduit cap 56 max. 30 ±0.2 42 (3) 14.2 +0.15 56 max. 30 Two, 4 dia. holes 0 +0.15 Depth: 5 Two, 4 dia. holes 0 Depth: 5 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. v Snap-action (1NC/1NO) (2NC), Slow-action (2NC) Slow-action (1NC/1NO) (2NC/1NO) (3NC) Model D4N-@A62 D4N-@A72 D4N-@A2G D4N-@A2H D4N-@C62 D4N-@C72 D4N-@C2G D4N-@C2H Model D4N-@162 D4N-@172 D4N-@12G D4N-@12H D4N-@E62 D4N-@E72 D4N-@E2G D4N-@E2H D4N-@262 D4N-@272 D4N-@22G D4N-@22H D4N-@F62 D4N-@F72 D4N-@F2G D4N-@F2H D4N-@B62 D4N-@B72 D4N-@B2G D4N-@B2H Operating characteristics *1 *2 D4N-@D62 D4N-@D72 D4N-@D2G D4N-@D2H Operating force OF max. 5.0 N 5.0 N 4.5 N 4.5 N Operating characteristics *1 *2 Release force RF min. 0.8 N 0.8 N 0.4 N 0.4 N Operating force OF max. 5.0 N 5.0 N 4.5 N 4.5 N Pretravel PT max. 4 mm 4 mm 18° to 27° 18° to 27° Release force RF min. 0.8 N 0.8 N 0.4 N 0.4 N (NC) Pretravel PT max. 4 mm 4 mm 18° to 27° 18° to 27° PT (NO) (5.2 mm) (4.3 mm) (44°)(44°) Overtravel OT min. 5 mm 5 mm 40° 40° *3 Movement differential 1.5 mm 1.5 mm 14° 14° PT max. 4 mm 4 mm 27.5° to 36.5° 27.5° to 36.5° MD max. *3 (NC) *4 PT (NO) (1.5 mm) (1.5 mm) (18°)(18°) Operating position OP 37 ±0.8 mm 27 ±0.8 mm --- --- *3, 4 Total travel TT *4 (9 mm) (9 mm) (70°)(70°) Overtravel OT min. 5 mm 5 mm 40° 40° Direct opening travel 5.8 mm 4.8 mm 50° 50° Operating position OP 37 ±0.8 mm 27 ±0.8 mm --- --- DOT min. *5 26.1 Direct opening force 20 N 20 N 20 N 20 N OP *4 36 ±0.8 mm --- --- ±0.8 mm DOF min. *5 Total travel TT *3 (9 mm) (9 mm) (70°)(70°) Note: Variation occurs in the simultaneity of contact opening/closing Direct opening travel 5.8 mm 4.8 mm 50° 50° operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact DOT min. *5 operation. Direct opening force 20 N 20 N 20 N 20 N *1. The operating characteristics of these Switches were measured DOF min. *5 with the roller lever set at 30 mm. *1. The operating characteristics of these Switches were measured *2. The operating characteristics of these Switches were measured with the roller lever set at 30 mm. with the roller lever set at 31 mm. *2. The operating characteristics of these Switches were measured *3. Only for snap-action models. with the roller lever set at 31 mm. *4. Reference value. *3. Reference values. *5. For safe use, always make sure that the minimum values or greater *4. Only for MBB models. (D4N-@E@@ or D4N-@F@@) are provided. *5. For safe use, always make sure that the minimum values or greater are provided. 15 D4N Levers Refer to the following for the angles and positions of the watchdogs (source: EN50047.) Roller Lever Adjustable Roller Lever, Form Lock Adjustable Roller Lever, Form Lock (D4N-@@20) (with Metal Lever, Resin Roller) (with Metal Lever, Rubber Roller) (D4N-@@2G) (Reference Values) (D4N-@@2H) (Reference Values) ±7 30 ±2 40 10 min. 30° ±2 40 ±7 29 42±2 Dog 10 min. ±3 15±3 11 45 min. 10 min. Dog 30° Dog 40 min. 20 min. ±2 30° 5 25 min. 110 55 5 min. 90 +1 70 15 min. 30° +1 0 75 40 0 +1 +1 55 0 55 0 +1 45 35 0 50 max. 65R 31R 65R 20R Roller Plunger Sealed Plunger (D4N-@@32) (D4N-@@31) 0 12.5 −2.5 10±1.5 0 12.5 −2.5 Dog Dog Operating position 2.5 Operating position 20 min. 30° Dog 35 31 min. ±0.5 21 min. +1 18 25 min. 25 15 min. 0 10 min. ±1 28 One-way Roller Arm Lever One-way Roller Arm Lever (Horizontal) (Vertical) (Reference Values) (D4N-@@62) (D4N-@@72) 0 12.5 −2.5 0 12.5 −2.5 ±2 10 Dog 10 min. 31 5 min. Dog 20 min. 30° 30° 5 min. 40 +1 31 ±2 41 0 30 max. 10 min. +1 22 20 min. 0 Fork Lever Lock Fork Lever Lock (Right Operation) (Left Operation) (D4N-@@RE) (D4N-@@LE) 40 40 Mounting Mounting 55° to 60° 55° to 60° surface surface 60 60 36 36 5 to 9R 28 28 5 to 9R Dog setting range Dog setting range Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 16 D4N Safety Precautions Be sure to read the precautions for All Safety Limit Switches in the website at:http://www.ia.omron.com/. Indication and Meaning for Safe Use 3 Indicates a potentially hazardous situation which, if not avoided, may result in minor CAUTION or moderate injury or in property damage. 4 5 Precautions Supplementary comments on what to do or avoid doing, to use the product safely. 1 for Safe Use 7 Supplementary comments on what to do Precautions or avoid doing, to prevent failure to 6 2 for Correct operate, or undesirable effect on product Use performance. Switch Mounting • Mount the Switch using M4 screws and spring washers and tighten !CAUTION the screws to the specified torque. • For safety, use screws that cannot be easily removed, or use an Electric shock may occasionally occur. equivalent measure to ensure that the Switch is secure. Do not use metal connectors or metal conduits. • As shown below, two studs with a maximum height of 4.8 mm and −0.05 a diameter of 4−0.15 mm can be provided, the studs inserted into the holes on the bottom of the Switch, and the Switch secured at four Precautions for Safe Use locations to increase the mounting strength. • Do not use the Switch submerged in oil or water, or in locations Switch Mounting Holes continuously subject to splashes of oil or water. Doing so may result in oil or water entering the Switch interior. (The IP67 degree One-conduit Type Two-conduit Type of protection specification for the Switch refers to water penetration ±0.1 Two, M4 2.5 Two, M4 ±0.1 2.5 while the Switch is submersed in water for a specified period of ±0.1 5.35 time.) 20±0.1 ±0.1 • Always attach the cover after completing wiring and before using 20 ±0.1 22 ±0.1 22 the Switch. Also, do not turn ON the Switch with the cover open. ±0.1 39 40±0.1 ±0.1 47 Doing so may result in electric shock. ±0.1 42 • Do not switch circuits for two or more standard loads (250 VAC, 3 A). Doing so may adversely affect insulation performance. ±0.1 42 −0.05 Precautions for Correct Use 22±0.1 −0.05 4 dia. −0.15 4 dia. −0.15 Height: 4.8 max. Height: 4.8 max. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, • Make sure that the dog contacts the actuator at a right angle. however, they cannot be used to switch smaller loads. The contact Applying a load to the switch actuator (roller) on a slant may result surfaces will become rough once they have been used and contact in deformation or damage of the actuator or rotary shaft. reliability for smaller loads may be reduced. Dog Mounting Method Appropriate Tightening Torque Tighten each of the screws to the specified torque. Loose screws may Incorrect Correct result in malfunction of the Switch within a short time. 1 Terminal screw 0.6 to 0.8 N·m 2 Cover mounting screw 0.5 to 0.7 N·m 3 Head mounting screw 0.5 to 0.6 N·m 4 Lever mounting screw 1.6 to 1.8 N·m 5 Body mounting screw 0.5 to 0.7 N·m 6 Connector, M12 adaptor 1.8 to 2.2 N·m 7 Cap screw 1.3 to 1.7 N·m 17 Dog D4N Wiring Wiring Contact Arrangement • When connecting to the terminals via insulating tube and M3.5 • The contact arrangements are shown below. crimp terminals, arrange the crimp terminals as shown below so Screw Terminal Type that they do not rise up onto the case or the cover. 2 Applicable lead wire size: AWG20 to AWG18 (0.5 to 0.75 mm ). D4N-@C@@ (2NC/1NO) Use lead wires of an appropriate length, as shown below. Not D4N-@D@@ (3NC) D4N-@F@@ (2NC/1NO (MBB)) doing so may result in excess length causing the cover to rise and 11 12 11 12 not fit properly. 21 22 21 22 One-conduit Type (3 Poles) 31 32 33 34 A B A B C D D4N-@B@@ (2NC) D4N-@A@@ (1NC/1NO) 11 12 E F D4N-@2@@ (2NC (SNAP)) D4N-@E@@ (1NC/1NO (MBB)) C D 21 22 42 mm 11 12 11 12 33 mm 28 mm E F 33 34 31 32 33 34 Tolerance ±2 mm D4N-@1@@ (1NC/1NO (SNAP)) Two-conduit Type (3 Poles) 13 14 Left hand Right hand E C A BD F 31 32 A B 11 12 BD F E C A Connector Type C D 21 22 42 mm 42 mm D4N-9B@@ (2NC) D4N-9A@@ (1NC/1NO) 28 mm 28 mm E F 33 34 D4N-92@@ (2NC (SNAP)) D4N-9E@@ (1NC/1NO (MBB)) (1) 11 12 (2) (1) 11 12 (2) Tolerance ±2 mm Tolerance ±2 mm (3) 31 32 (4) (3) 33 34 (4) • Do not push crimp terminals into gaps in the case interior. Doing so may cause damage or deformation of the case. D4N-91@@ (1NC/1NO (SNAP)) 1 • Use crimp terminals not more than 0.5 mm in thickness. Otherwise, (3) 13 14 (4) they will interfere with other components inside the case. 24 3 [Reference] The crimp terminals shown below are not more than (1) 31 32 (2) 0.5 mm thick. Pin No. (Terminal No.) Manufacturer Type • Applicable socket: XS2F-D421 series (OMRON). • Refer to the Connector Catalog for details on socket pin numbers FN0.5-3.7 (F Type) J.S.T. Mfg. Co. and lead wire colors. N0.5-3.7 (Straight Type) L Socket Tightening (Connector Type) l F t: 0.5 mm • Turn the socket connector screws by hand and tighten until no dz dia.: 3.7 mm space remains between the socket and the plug. D dia.: 2.9 mm B: 6.6 mm • Make sure that the socket connector is tightened securely. B D dia. L: 19 mm Otherwise, the rated degree of protection (IP67) may not be F: 7.7 mm I: 8.0 mm maintained and vibration may loosen the socket connector. dz dia. Conduit Opening Crimp terminal Terminal screw • Connect a recommended connector to the opening of the conduit and tighten the connector to the specified torque. The case may be damaged if an excessive tightening torque is applied. • Use a cable with a suitable diameter for the connector. • Attach and tighten a conduit cap to the unused conduit opening Correct Incorrect when wiring. Tighten the conduit cap to the specified torque. The conduit cap is provided with the Switch (2-conduit types). Changing the Lever The lever mounting screws can be used to set the lever position to any position in a 360° angle at 7.5° increments. Grooves are incised on the lever and rotary shaft that engage to prevent the lever from slipping against the rotary shaft. The screws on adjustable roller lever models can also loosened to change the length of the lever. Remove the screws from the front of the lever before mounting the lever in reverse (front/back), and set the level so that operation will be completed before exceeding a range of 180° on the horizontal. 18 D4N Recommended Connectors Use connectors with screws not exceeding 9 mm, otherwise the screws will protrude into the case interior, interfering with other components in the case. The connectors listed in the following table have connectors with thread sections not exceeding 9 mm. Use the recommended connectors to ensure conformance to IP67. Applicable cable Size Manufacturer Model diameter ST-PF1/2 G1/2 LAPP 6.0 to 12.0 mm 5380-1002 ST-13.5 Pg13.5 LAPP 6.0 to 12.0 mm 5301-5030 ST-M20 × 1.5 M20 LAPP 7.0 to 13.0 mm 5311-1020 Use LAPP connectors together with seal packing (JPK-16, GP-13.5, or GPM20), and tighten to the specified tightening torque. Seal packing is sold separately. • LAPP is a German manufacturer. Others • When attaching a cover, be sure that the seal rubber is in place and that there is no foreign material present. If the cover is attached with the seal rubber out of place or if foreign material is stuck to the rubber, a proper seal will not be obtained. • Do not use any screws to connect the cover other than the specified ones. The seal characteristics may be reduced. • Make sure that foreign particles do not enter the head when removing the screws from the four corners to change the head position in any of the four directions. • Use the following recommended countermeasures to prevent telegraphing when using adjustable or long levers. 1. Make the rear edge of the dog smooth with an angle of 15° to 30° or make it in the shape of a quadratic curve. 2. Design the circuit so that no error signal will be generated. 19 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.10 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the D4N-9132?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
Related Products

Switch Limit N.O./N.C. SPDT Side Roller Lever Conduit 10A 600VAC 250VDC Rotary Screw Mount D4A-1101-...

Switch Limit N.O./N.C. SPDT Side Roller Lever Conduit 10A 600VAC 250VDC Rotary Screw Mount D4A1101NF

Switch Limit N.O./N.C. SPDT Side Roller Lever Conduit 10A 600VAC 250VDC Rotary Screw Mount D4A-1102-...

Switch Limit N.O./N.C. SPDT Side Roller Lever Conduit 10A 600VAC 250VDC Rotary Screw Mount D4A-1103-...
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods