Electronics Finder chervon right Manufacturers chervon right O chervon right OMRON AUTOMATION chervon right G3PB-525B-2N-VDDC12-24
About product Specifications Datasheet FAQ

OMRON AUTOMATION G3PB-525B-2N-VDDC12-24

Image of OMRON AUTOMATION G3PB-525B-2N-VDDC12-24

Description

Relay SSR 10mA 30V DC-IN 25A 528V AC-OUT 8-Pin
G3PB-525B-2N-VDDC12-24

Part Number

G3PB-525B-2N-VDDC12-24

Price

Request Quote

Manufacturer

OMRON AUTOMATION

Lead Time

Request Quote

Category

Relays and I/O Modules »  Solid State Relay

Specifications

Manufacturer

Omron Automation

Manufacturers Part #

G3PB-525B-2N-VDDC12-24

Industry Aliases

G3PB-525B-2N-VD DC12-24V

Sub-Category

Solid State Relays

Factory Pack Quantity

1

Datasheet

pdf file

g3pb-2n_-3n_dsheet_csm169.pdf

1376 KiB

Extracted Text

Solid State Contactors (New Heat Sink Construction) G3PB-2N/-3N CSM_G3PB-2N_-3N_DS_E_2_1 Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications. • A comprehensive lineup that now includes 480-VAC models.  Slim design with 3-phase output and built-in heat sinks.  New heat sink construction with smaller mounting section.  DIN track mounting supported as standard. (Screw mounting is also possible.)  Certified by UL, CSA, and VDE. Refer to Safety Precautions for All Solid State Relays. Model Number Structure ■ Model Number Legend G3PB-@@@-@@-@ 23 4 5 6 7 1 1. Basic Model Name G3PB: Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 5: 480 VAC 3. Rated Load Current 15: 15 A 25: 25 A 35: 35 A 45: 45 A 4. Terminal Type B: Screw terminals 5. Single-phase/3-phase and Number of Elements for 3-phase 2: 3-phase, 2-element models 3: 3-phase, 3-element models 6. 3-phase Type N: DIN track mounting and built-in heat sink H: No heat sink (“hockey puck” type) 7. Certification VD: Certified by UL, CSA, and VDE 1 G3PB-2N/-3N Ordering Information ■ Solid State Contactors Models with Built-in Heat Sinks Applicable Main circuit voltage Zero cross Applicable load current Number of Model phase function (with Class-1 AC resistive load) poles 3 100 to 240 VAC Yes 15 A 3 G3PB-215B-3N-VD DC12-24 2 G3PB-215B-2N-VD DC12-24 25 A 3 G3PB-225B-3N-VD DC12-24 2 G3PB-225B-2N-VD DC12-24 35 A 3 G3PB-235B-3N-VD DC12-24 2 G3PB-235B-2N-VD DC12-24 45 A 3 G3PB-245B-3N-VD DC12-24 2 G3PB-245B-2N-VD DC12-24 200 to 480 VAC 15 A 3 G3PB-515B-3N-VD DC12-24 2 G3PB-515B-2N-VD DC12-24 25 A 3 G3PB-525B-3N-VD DC12-24 2 G3PB-525B-2N-VD DC12-24 35 A 3 G3PB-535B-3N-VD DC12-24 2 G3PB-535B-2N-VD DC12-24 45 A 3 G3PB-545B-3N-VD DC12-24 2 G3PB-545B-2N-VD DC12-24 Note: The applicable load current depends on the ambient temperature. When ordering, specify the rated input voltage. Models with Externally Attached Heat Sinks Applicable Main circuit voltage Zero cross Applicable load current Number of Model phase function (See note.) poles 3 100 to 240 VAC Yes 15 A 3 G3PB-215B-3H-VD DC12-24 2 G3PB-215B-2H-VD DC12-24 25 A 3 G3PB-225B-3H-VD DC12-24 2 G3PB-225B-2H-VD DC12-24 35 A 3 G3PB-235B-3H-VD DC12-24 2 G3PB-235B-2H-VD DC12-24 45 A 3 G3PB-245B-3H-VD DC12-24 2 G3PB-245B-2H-VD DC12-24 200 to 480 VAC 15 A 3 G3PB-515B-3H-VD DC12-24 2 G3PB-515B-2H-VD DC12-24 25 A 3 G3PB-525B-3H-VD DC12-24 2 G3PB-525B-2H-VD DC12-24 35 A 3 G3PB-535B-3H-VD DC12-24 2 G3PB-535B-2H-VD DC12-24 45 A 3 G3PB-545B-3H-VD DC12-24 2 G3PB-545B-2H-VD DC12-24 Note: The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. 2 G3PB-2N/-3N Specifications ■ Ratings (at an Ambient Temperature of 25°C) Operating Circuit (Common) Item Common Rated voltage 12 to 24 VDC Operating voltage range 9.6 to 30 VDC Rated input current (Impedance) 10 mA max. (at 24 VDC) Must operate voltage 9.6 VDC max. Must release voltage 1 VDC min. Insulation method Phototriac coupler Operation indicator Yellow LED Main Circuit of Models with Built-in Heat Sinks G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- Model 215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B- Item 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD Rated load voltage 100 to 240 VAC 200 to 480 VAC Load voltage range 75 to 264 VAC 180 to 528 VAC Applicable load 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) current (See note 1.) Minimum load cur- 0.2 A 0.5 A rent Inrush current re- 150 A 220 A 440 A 220 A 440 A sistance (60 Hz, 1 cy- (60 Hz, 1 cy- (60 Hz, 1 cycle) (60 Hz, 1 cycle) (60 Hz, 1 cycle) (peak value) cle) cle) 2 2 2 2 2 2 Permissible I t 121 A s 260 A s 1260 A s260 A s 1260 A s (half 60-Hz wave) Applicable load 5.1 kW max. 8.6 kW max. 12.1 kW max. 15.5 kW max. 12.5 kW max. 20.7 kW max. 29.0 kW max. 37.4 kW max. (resistive load, (at 200 VAC) (at 200 VAC) (at 200 VAC) (at 200 VAC) (at 480 VAC) (at 480 VAC) (at 480 VAC) (at 480 VAC) AC1) (See note 2.) Note: 1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. 2. Applicable Load Use the following formula to calculate the maximum total capacity of a heater load for a three-phase balanced load with delta connections. Maximum load capacity = Load current × Load voltage × 3 Example: 15 A × 200 V × 3 = 5.196 W ≅ 5.1 kW Example: 15 A × 400 V × 3 = 10.392 W ≅ 10.3 kW Main Circuit of Models with Externally Attached Heat Sinks Model G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB -215B -215B -225B -225B -235B -235B -245B -245B -515B -515B -525B -525B -535B -535B -545B -545B Item -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD Rated load 100 to 240 VAC 200 to 480 VAC voltage Load voltage 75 to 264 VAC 180 to 528 VAC range Applicable 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) load current (See note.) Minimum load 0.2 A 0.5 A current Inrush 150 A (60 Hz, 220 A (60 Hz, 440 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) current 1 cycle) 1 cycle) resistance (peak value) 2 2 2 2 2 Permissible 121 A s 260 A s 1,260 A s 260 A s 1,260 A s 2 I t (half 60-Hz wave) Applicable Refer to Engineering Data on page 5. load (resistive load, AC1) Note: The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. 3 G3PB-2N/-3N ■ Characteristics Models with Built-in Heat Sinks G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- Item 215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B- 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON 1.6 V (RMS) max. 1.8 V (RMS) max. voltage drop Leakage 10 mA (at 200 VAC) 20 mA (at 480 VAC) current (See note.) Insulation 100 MΩ min. (at 500 VDC) resistance Dielectric 2,500 VAC, 50/60 Hz for 1 min strength Vibration Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track) resistance 2 2 Shock resis- Destruction: 294 m/s (98 m/s with reverse mounting) tance Ambient Operating: –30°C to 80°C (with no icing or condensation) operating Storage: –30°C to 100°C (with no icing or condensation) temperature Ambient Operating: 45% to 85% operating humidity Weight Approx. Ap- Ap- Ap- Ap- Ap- Ap- Approx. Ap- Ap- Ap- Ap- Ap- Ap- 1.25 kg prox. prox. prox. prox. prox. prox. 1.25 kg prox. prox. prox. prox. prox. prox. 1.45 1.25 1.65 1.45 2.0 kg 1.65 1.45 1.25 1.65 1.45 2.0 kg 1.65 kg kg kg kg kg kg kg kg kg kg Certified UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE standards (From April 2001) EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Note: The leakage current of phase S will be approximately 3 times larger if the 2-element model is applied. Models with Externally Attached Heat Sinks G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB Model -215B -215B -225B -225B -235B -235B -245B -245B -515B -515B -525B -525B -535B -535B -545B -545B Item -3H-VD -2H-VD -3H-VD -2HVD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON 1.6 V (RMS) max. 1.8 V (RMS) max. voltage drop Leakage 10 mA (at 200 VAC) 20 mA (at 480 VAC) current (See note.) Insulation 100 MΩ min. (at 500 VDC) resistance Dielectric 2,500 VAC, 50/60 Hz for 1 min strength Vibration Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) resistance 2 2 Shock Destruction: 294 m/s (98 m/s with reverse mounting) resistance Storage –30°C to 100°C (with no icing or condensation) temperature Ambient –30°C to 80°C (with no icing or condensation) operating temperature Ambient 45% to 85% storage humidity Weight Approx. 300 g Note: The leakage current of phase S will be approximately 3 times larger if the 2-element model is used. 4 G3PB-2N/-3N Engineering Data Load Current vs. Ambient Temperature Models with Built-in Heat Sinks G3PB-215B-3N-VD G3PB-225B-3N-VD G3PB-235B-3N-VD G3PB-225B-2N-VD G3PB-235B-2N-VD G3PB-215B-2N-VD 30 30 50 Derating curve under UL standard Derating curve under UL standard 25 25 40 22 35 20 20 30 28 15 Derating curve under 20 UL standard 10 10 14 8 7 10 6 8 0 0 0 -30 -20 0 20 25 40 60 80 100 −30 −20 0 20 25 40 60 80 100 −30 −20 0 20 40 60 80 100 Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 28 A is applicable under the UL standard only with forced air cooling by fan. G3PB-245B-3N-VD G3PB-515B-3N-VD G3PB-525B-3N-VD G3PB-515B-2N-VD G3PB-245B-2N-VD G3PB-525B-2N-VD 50 30 30 Derating curve under UL standard 45 Derating curve under UL standard 42 25 25 40 22 20 20 30 15 Derating curve under 20 UL standard 18 10 10 12 8 7 10 6 0 0 0 −30 −20 0 20 25 40 60 80 100 −30 −20 0 20 40 60 80 100 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 42 A is 2. Please note that the derating curve above 22 A is applicable under the UL standard only with forced applicable under the UL standard only with forced air cooling by fan. air cooling by fan. G3PB-535B-3N-VD G3PB-545B-3N-VD G3PB-545B-2N-VD G3PB-535B-2N-VD 50 50 Derating curve under UL standard Derating curve under UL standard 45 42 40 40 35 30 30 28 20 20 18 14 12 10 10 8 0 0 −30 −20 0 20 25 40 60 80 100 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 28 A is 2. Please note that the derating curve above 42 A is applicable under the UL standard only with forced applicable under the UL standard only with forced air cooling by fan. air cooling by fan. 5 Load current (A) Load current (A) Load current (A) Load current (A) Load current (A) Load current (A) Load current (A) Load current (A) G3PB-2N/-3N Load Current vs. Ambient Temperature Models without Built-in Heat Sinks G3PB-215B-3H(-2H)-VD G3PB-235B-3H(-2H)-VD G3PB-225B-3H(-2H)-VD G3PB-245B-3H(-2H)-VD G3PB-515B-3H(-2H)-VD G3PB-535B-3H(-2H)-VD G3PB-525B-3H(-2H)-VD G3PB-545B-3H(-2H)-VD 10 10 Derating curve under UL standard G3PB-225B-3(-2)H-VD 8 G3PB-525B-3(-2)H-VD 8 Derating curve under UL standard 6 6 5 5 4 4 G3PB-215B-3(-2)H-VD G3PB-515B-3(-2)H-VD 2 2 1.5 1.5 0 0 0 20 40 60 80 100 −30 −20 −30 −20 20 25 40 60 80 100 0 Ambient temperature (°C) Ambient temperature (°C) Note: Please use proper ventilation and cooling. Note: Please use proper ventilation and cooling. Input Voltage vs. Input Current and Input Voltage vs. Input Impedance Input current Input impedance Input voltage (V) One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. G3PB-215B-3N/3H-VD G3PB-225B-3N/3H-VD G3PB-235B-3N/3H-VD G3PB-215B-2N/2H-VD G3PB-225B-2N/2H-VD G3PB-235B-2N/2H-VD G3PB-515B-3N/3H-VD G3PB-245B-3N/3H-VD G3PB-515B-2N/2H-VD G3PB-245B-2N/2H-VD G3PB-525B-3N/3H-VD G3PB-535B-3N/3H-VD G3PB-525B-2N/2H-VD G3PB-535B-2N/2H-VD G3PB-545B-3N/3H-VD G3PB-545B-2N/2H-VD Energized time (ms) Energized time (ms) Energized time (ms) 6 Input impedance (kΩ) Load current (A) Inrush current Input current (mA) Inrush current Load current (A) Inrush current G3PB-2N/-3N Dimensions Note: All units are in millimeters unless otherwise indicated. G3PB-215B-3N-VD Without Terminal Cover With Terminal Cover G3PB-215B-2N-VD Two, 4.6-dia. mounting holes Four, 8 dia. G3PB-225B-2N-VD Two, M3.5 G3PB-515B-3N-VD G3PB-515B-2N-VD 80.5 100 G3PB-525B-2N-VD 24 68 90 max. max. Two, R2.3 mounting holes 0.5 64 20 20 Six, M4 80 max. 32.2 68 Mounting Hole Dimensions 30.5 max. 64±0.3 19.4 14.6 90±0.3 120 max. Four, 4.5-dia. or M4 Terminal Arrangement/Internal Connections G3PB-215B-3N-VD G3PB-2@5B-2N-VD G3PB-515B-3N-VD G3PB-5@5B-2N-VD (+) (+) (+) (+) L1/R L2/S L3/T L1/R L2/S L3/T L1/R L2/S L3/T L1/R L2/S L3/T A1 A1 A1 A1 A2 A2 A2 A2 T1/U T2/V T3/W T1/U T2/V T3/W T1/U T2/V T3/W T1/U T2/V T3/W (−) (−) (−) (−) G3PB-225B-3N-VD Without Terminal Cover With Terminal Cover G3PB-235B-2N-VD Two, 4.6-dia. mounting holes Four, 8 dia. G3PB-525B-3N-VD Two, M3.5 G3PB-535B-2N-VD 80.5 120 24 68 100 110 max. max. Two, R2.3 mounting holes 0.5 64 Six, M5 (35 A type) 20 20 Six, M4 (25 A type) 80 max. 32.2 68 Mounting Hole Dimensions 30.5 64±0.3 max. 19.4 14.6 110±0.3 120 max. Four, 4.5-dia. or M4 Terminal Arrangement/Internal Connections G3PB-225B-3N-VD G3PB-235B-2N-VD G3PB-525B-3N-VD G3PB-535B-2N-VD (+) (+) (+) (+) L1/R L2/S L3/T L1/R L2/S L3/T L1/R L2/S L3/T L1/R L2/S L3/T A1 A1 A1 A1 A2 A2 A2 A2 T1/U T2/V T3/W T1/U T2/V T3/W T1/U T2/V T3/W T1/U T2/V T3/W (−) (−) (−) (−) 7 Input circuit Input circuit Input circuit Input circuit Input circuit Input circuit Input circuit Input circuit G3PB-2N/-3N G3PB-235B-3N-VD Without Terminal Cover With Terminal Cover G3PB-245B-2N-VD Two, 4.6-dia. mounting holes Four, 8 dia. G3PB-535B-3N-VD G3PB-545B-2N-VD Two, M3.5 80.5 140 24 68 120 130 max. max. Two, R2.3 mounting holes 0.5 Six, M5 64 20 20 80 max. 32.2 68 Mounting Hole Dimensions 30.5 64±0.3 19.4 max. 14.6 120 max. 130±0.3 Four, 4.5-dia. or M4 Terminal Arrangement/Internal Connections G3PB-235B-3N-VD G3PB-245B-2N-VD G3PB-535B-3N-VD G3PB-545B-2N-VD (+) (+) (+) (+) L1/R L2/S L3/T L1/R L2/S L3/T L1/R L2/S L3/T L1/R L2/S L3/T A1 A1 A1 A1 A2 A2 A2 A2 T1/U T2/V T3/W T1/U T2/V T3/W T1/U T2/V T3/W T1/U T2/V T3/W (−) (−) (−) (−) G3PB-245B-3N-VD Without Terminal Cover With Terminal Cover G3PB-545B-3N-VD Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 80.5 140 24 68 120 130 Two, R2.3 max. max. mounting holes 0.5 Six, M5 64 20 20 80 max. 32.2 110 max. 68 Mounting Hole Dimensions 30.5 64±0.3 19.4 max. 14.6 120 max. 130±0.3 Terminal Arrangement/Internal Connections G3PB-245B-3N-VD G3PB-545B-3N-VD Four, 4.5-dia. or M4 (+) (+) L1/R L2/S L3/T L1/R L2/S L3/T A1 A1 A2 A2 T1/U T2/V T3/W T1/U T2/V T3/W (−) (−) 8 Input circuit Input circuit Input circuit Input circuit Input circuit Input circuit G3PB-2N/-3N ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 9 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: · Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. · Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. · Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the G3PB-525B-2N-VDDC12-24?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Relay SSR 7mA 30V DC-IN 10A 264V AC-OUT G32A-A10-VDDC5-24

product

Relay SSR 7mA 30V DC-IN 40A 264V AC-OUT G32A-A40-VDDC5-24

product

Relay SSR 7mA 30V DC-IN 20A 528V AC-OUT G32AA420VD2DC1224

product

Relay SSR 7mA 30V DC-IN 20A 528V AC-OUT G32AA420VDDC1224

product

Relay SSR 7mA 30V DC-IN 30A 528V AC-OUT G32A-A430-VD-2DC12-24

product

Relay SSR 7mA 30V DC-IN 30A 528V AC-OUT 4-Pin G32A-A430-VDDC12-24