OMRON AUTOMATION S82J01012D

Why buy from GID?

Quality

We are industry veterans who take pride in our work

Protection

Avoid the dangers of risky trading in the gray market

Access

Our network of suppliers is ready and at your disposal

Savings

Maintain legacy systems to prevent costly downtime

Speed

Time is of the essence, and we are respectful of yours

Details

Part Number S82J01012D
Manufacturer OMRON AUTOMATION
Category Circuit Protection »  AC-DC Power Supply
Price Request Quote
Lead Time Request Quote

Description

AC/DC Power Supply Single-OUT 12V 1A 10W 5-Pin
S82J01012D

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Electronics Finder is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a S82J01012D? We can help you find it at a competitive price!

Specifications

Manufacturer Omron Automation
Manufacturers Part # S82J01012D
Industry Aliases S82J-01012D
Sub-Categories AC-DC Power Supplies
Factory Pack Quantity 1

Datasheet

Download "s82j.pdf" (384 KiB)

Extracted Text

Switching Power Supply S82J Compact and Economical Switching Power Supplies with Capacities Up to 600 W DIN Track Mounting Bracket Type Now Available Power range from 10 W up to 600 W. Output Voltages: 5 V, 12 V, 15 V, or 24 V. Wide AC input range 10-/25-/50-/100-W, 24-V output models: 100 to 240 VAC on one body 100-W, 5-/12-/15-V output and 150-W models: 100 or 200 VAC selected automatically 300-/600-W models: 100 or 200 VAC selectable Top terminal- and connector-type available with specific models in addition to front terminal type. Mounting bracket provided for mounting to control panels. Maintenance-free up to 300 W due to natural ventilation. Protection-ON alarm indicator shows valuable protection functions in action (300-/600-W models). Conforms to EMC standards: EN50081-2 and EN50082-2. With an external filter, achieves conformance to EN50081-1 for universal usage on EMI (300-/600-W models). Finger protection terminal block to meet VDE0106/P100 Class 2 approved (10-/25-/50-W models) UL508 approved. All models can be used at full load in UL508A industrial control panel applications. Approved by UL/CSA standards, EN60950, and EN50178 (VDE0160). Six-language instruction manual provided. (English, French, German, Italian, Spanish, and Japanese) uRCW S82J Covered Type Open-frame Type Enclosure Type <10 W to 150 W> <300/600 W> <10 W to 150 W> • 100 to 240-VAC input • 100 or 200 VAC • 100 to 240-VAC input (selectable) • 100 or 200 VAC (selected • 100 or 200 VAC (selected automatically) automatically) (100-W 5-/12-/15-V output, (100-W 5-/12-/15-V output, 150-W models) 150-W models) 1 S82J S82J Ordering Information Front-mounting Bracket Type Configuration Input Power Output Output Front terminals Top terminals Connector Voltage ratings voltage current Open-frame Ope a e 100 to 00 o 10 W 5 V 2 A S82J-01005A --- --- t type 240 240 V VAC AC 12 V 1 A S82J-01012A --- --- 15 V 0.7 A S82J-01015A --- --- 24 V 0.5 A S82J-01024A --- --- 25 W 5 V 5 A S82J-02505A --- --- 12 V 2.1 A S82J-02512A --- --- 15 V 1.7 A S82J-02515A --- --- 24 V 1.1 A S82J-02524A --- --- 50 W 5 V 10 A S82J-05005A --- --- 12 V 4.2 A S82J-05012A --- --- 24 V 2.1 A S82J-05024A --- --- 100 or 100 W 5 V 20 A S82J-10005A S82J-10005B S82J-10005C 200 200 V VAC AC 12 V 8.5 A S82J-10012A S82J-10012B S82J-10012C ( (selected selected automatically) 15 V 7 A S82J-10015A S82J-10015B S82J-10015C 100 to 24 V 4.5 A S82J-10024A --- --- 240 VAC 100 or 150 W 24 V 6.5 A S82J-15024A S82J-15024B S82J-15024C 200 VAC (selected automatically) Covered type Co e ed ype 100 to 00 o 10 W 5 V 2 A S82J-01005D --- --- 240 240 V VAC AC 12 V 1 A S82J-01012D --- --- 15 V 0.7 A S82J-01015D --- --- 24 V 0.5 A S82J-01024D --- --- 25 W 5 V 5 A S82J-02505D --- --- 12 V 2.1 A S82J-02512D --- --- 15 V 1.7 A S82J-02515D --- --- 24 V 1.1 A S82J-02524D --- --- 50 W 5 V 10 A S82J-05005D --- --- 12 V 4.2 A S82J-05012D --- --- 24 V 2.1 A S82J-05024D --- --- 100 or 100 W 5 V 20 A S82J-10005D S82J-10005E S82J-10005F 200 200 V VAC AC 12 V 8.5 A S82J-10012D S82J-10012E S82J-10012F ( (selected selected automatically) 15 V 7 A S82J-10015D S82J-10015E S82J-10015F 100 to 24 V 4.5 A S82J-10024D --- --- 240 VAC 100 or 150 W 24 V 6.5 A S82J-15024D S82J-15024E S82J-15024F 200 VAC (selected automatically) 100 or 00 o 300 W 300 24 V 14 A S82J-30024 --- --- 200 200 V VAC AC S82J-30024N --- --- (selectable) (selectable) 600 W 600 27 A S82J-60024 --- --- S82J-60024N --- --- 2 S82J S82J DIN Track Mounting Bracket Type Configuration Input Power Output Output Front terminals Top terminals Connector Voltage ratings voltage current Open-frame Ope a e 100 to 00 o 10 W 5 V 2 A S82J-01005AD --- --- t type 240 240 V VAC AC 12 V 1 A S82J-01012AD --- --- 15 V 0.7 A S82J-01015AD --- --- 24 V 0.5 A S82J-01024AD --- --- 25 W 5 V 5 A S82J-02505AD --- --- 12 V 2.1 A S82J-02512AD --- --- 15 V 1.7 A S82J-02515AD --- --- 24 V 1.1 A S82J-02524AD --- --- 50 W 5 V 10 A S82J-05005AD --- --- 12 V 4.2 A S82J-05012AD --- --- 24 V 2.1 A S82J-05024AD --- --- 100 or 100 W 5 V 20 A S82J-10005AD S82J-10005BD S82J-10005CD 200 200 V VAC AC 12 V 8.5 A S82J-10012AD S82J-10012BD S82J-10012CD ( (selected selected automatically) 15 V 7 A S82J-10015AD S82J-10015BD S82J-10015CD 100 to 24 V 4.5 A S82J-10024AD --- --- 240 VAC 100 or 150 W 24 V 6.5 A S82J-15024AD S82J-15024BD S82J-15024CD 200 VAC (selected automatically) Covered type Co e ed ype 100 to 00 o 10 W 5 V 2 A S82J-01005DD --- --- 240 240 V VAC AC 12 V 1 A S82J-01012DD --- --- 15 V 0.7 A S82J-01015DD --- --- 24 V 0.5 A S82J-01024DD --- --- 25 W 5 V 5 A S82J-02505DD --- --- 12 V 2.1 A S82J-02512DD --- --- 15 V 1.7 A S82J-02515DD --- --- 24 V 1.1 A S82J-02524DD --- --- 50 W 5 V 10 A S82J-05005DD --- --- 12 V 4.2 A S82J-05012DD --- --- 24 V 2.1 A S82J-05024DD --- --- 100 or 100 W 5 V 20 A S82J-10005DD S82J-10005ED S82J-10005FD 200 200 V VAC AC 12 V 8.5 A S82J-10012DD S82J-10012ED S82J-10012FD ( (selected selected automatically) 15 V 7 A S82J-10015DD S82J-10015ED S82J-10015FD 100 to 24 V 4.5 A S82J-10024DD --- --- 240 VAC 100 or 150 W 24 V 6.5 A S82J-15024DD S82J-15024ED S82J-15024FD 200 VAC (selected automatically) 3 S82J S82J Model Number Legend: S82J - 1 2 3 4 1.Power Ratings 2. Output Voltage 3. Configuration 010: 10 W 05: 5 V A: Open-frame type, front terminals 025: 25 W 12: 12 V B: Open-frame type, top terminals 050: 50 W 15: 15 V C: Open-frame type, connector 100: 100 W 24: 24 V D: Covered type, front terminals 150: 150 W E: Covered type, top terminals 300: 300 W F: Covered type, connector 600: 600 W N: Without Mounting Bracket None: Enclosure type, front terminals with 4. Mounting Bracket Mounting Bracket None: Front-mounting Bracket Type D: DIN Track Mounting Bracket Type 4 S82J S82J Specifications Ratings/Characteristics Item 100 to 240 VAC input 100 or 200 VAC 100 or 200 VAC (selected (selectable) automatically) 10 W 25 W 50 W 100 W 100 W (5, 150 W 300 W 600 W (24 V) 12, 15 V) Efficiency (typical) 67% min. (77% min. for 50-W, 24-V models) 83% min. 75.5% 82% min. min. Input Voltage 100 to 240 VAC (85 to 264 VAC) 100 (85 to 132) or 200 100 (85 to 132) or 200 110 to 170 VDC (set the terminal (L) to + side) (see note1) (170 to 264) VAC (170 to 253) VAC (selected (selectable) automatically) Frequency 50/60 Hz (47 to 450 Hz) Current 100 VAC 0.35 A 0.8 A 1.4 A max. 2.5 A 2.5 A 3.5 A 8 A max. 14 A max. (see note (see note input max. max. max. max. max. 2) 2) 200 VAC 0.3 A 0.6 A 0.8 A max. 1.5 A 1.4 A 2.1 A 4 A max. 7 A max. input max. max. max. max. max. Leakage 100 VAC 0.5 mA max. current current input (t (see note 200 VAC 1 mA max. 2) input Inrush 100 VAC 25 A max. 30 A max. current input ( (25 25°C, C, cold start) 200 VAC 50 A max. 60 A max. (see note input 2) Noise filter Yes Output Voltage adjustment ±10% (adjustable with variable resistor (V. ADJ)) (see note (see note range 3) 3) Ripple (see note 2) 2% (p-p) max. Input variation 0.4% max. influence Load variation 0.8% max. (with rated input, 10% to 100% load) influence Temperature variation 0.05%/°C max. (with rated input and output) influence Startup time 500 ms max. (up to 90% of output voltage at rated input and output) 300 ms max. (up to 90% of output voltage at rated input and output) Hold time (see note 2) 20 ms min. Additional Overload protection 105% to 160% of rated load current, inverted L drop/intermittent operation type, 105% min. of rated load function automatic reset current, inverted L drop type, automatic reset (For the 600-W model, the circuit will be shut OFF when the overload exceeds 5 ±3 s. Protection-ON alarm indicator lit (see note 4)) Overvoltage protection No Yes Yes (5-V No Yes, protection-ON (see note 5) output alarm indicator lit (see models note 4) only) Overheat protection No Yes, protection- ON alarm indicator lit (see note 4) Protection-ON alarm No Yes (color, red) indicator Parallel operation No Yes, 5 units max. Series operation No Yes 5 S82J S82J Item Item 100 to 240 VAC input 100 or 200 VAC 100 or 200 VAC (selected (selectable) automatically) 10 W 25 W 50 W 100 W 100 W (5, 150 W 300 W 600 W (24 V) 12, 15 V) Other Ambient temperature Operating: See the derating curve in the Engineering Data section. Storage: –25 to 65°C (with no condensation and icing) Ambient humidity Operating: 25% to 85% Storage: 25% to 90% Dielectric strength Dielectric strength 3.0 kVAC, 50/60 Hz for 1 min (between all inputs and all outputs) 2.2 kVAC, 50/60 Hz for 1 min (between all inputs and all inputs/GR terminal) 1.0 kVAC, 50/60 Hz for 1 min (between all outputs and GR terminal) Insulation resistance 100 MΩ min. (between all outputs and all inputs/GR terminals at 500 VDC) Vibration resistance 10 to 55 Hz, 0.375-mm double amplitude for 2 h each in X, Y, and Z directions 2 Shock resistance 300 m/s , 3 times each in ±X, ±Y, and ±Z directions Terminal screw 0.74 N � m 1.08 N � m tightening Output indicator Yes (green) Electromagnetic Conforms to FCC Class A interference (see note 2) EMC Emission Enclosure: EN55011 class A Emission AC Mains: EN55011 class A Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: ENV50140: 10 Vm (80 MHz to 1 GHz) (level 3) Immunity Conducted Disturbance: ENV50141: 10 V (0.5 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3) 2 kV output line (level 4) EMC standards Conforms to EN50081-2 and EN50082-2 Conforms to EN50081-2 and EN50082-2 (see note 6) With noise filter, confirms to EN50081-1 (see note 6 and 7) Approved UL UL508 (Listing), 1950, Class 2 (per UL1310) UL508 (Listing), 1012, 1950 (see UL508/1012 standards standards note 8) CSA CSA C22.2 No. 14, No. 950, Class 2 CSA C22.2 No. 14, No. 950 CSA EB1402C VDE EN50178 (VDE0160) and EN60950 Terminal types (only terminal part): VDE0106/P100 Weight (see note 9) 250 g 350 g 400 g max. 500 g 1,000 g max. 2,000 g 2,500 g max. max. max. max. max. Note: 1. DC inputs not included in safety standard approvals. 2. At 100% load for rated input voltage (100 VAC or 200 VAC). 3. The output specification is defined at the power supply output terminals. 4. For resetting, turn OFF the power supply, leave for more than three minutes, and then turn ON the power supply. 5. For resetting, turn OFF the power supply, leave for more than one minutes (90 seconds min. for the 300-W models and 3 minutes min. for the 600-W models), and then turn ON the power supply. 6. To ensure the Emission Enclosure rating ferrite ring cores (recommended model: S82Y-JC-T) should be used on all cabling. 7. To ensure the Emission AC Mains rating for EN50081-1 (only for 200-VAC input), a noise filter (recommended models: S82Y-JF3-N for 300-W, S82Y-JF6-N for 600-W) should be used on the input lines. 8. With UL508, 150-W connector type has “Recognized” approval. 9. The weight indicated is the weight of the open-frame type. (Includes the covers for 300-W and 600-W models) Reference Value Item Value Definition Reliability (MTBF) 135,000 hours min. MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. Therefore, it does not necessarily represent a life of the product. Life expectancy 10 yrs. min. The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%. Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor. 6 S82J S82J Engineering Data Derating Curve 10-/25-/50-/100-/150-W Model Open-frame type Covered-type Standard Installation Forced air-cooling 3 Forced air-cooling (1 m /min) 3 (1 m /min) Natural air-cooling Natural air-cooling Note: The derating curve shown is for standard installation. The derating curve depends on the mounting direction of the Power Supply. Ambient temperature (°C) Ambient temperature (°C) 300-W Model Single Operation Parallel Operation Standard mounting 120 Forced air-cooling 120 3 20 mm min. 20 mm min. (1 m /min) (Standard mounting) 100 Forced air-cooling 100 3 (1 m /min) Natural air-cooling (Standard mounting) (Standard mounting) Forced air-cooling 3 (1 m /min) (Side mounting) Natural air-cooling (Standard mounting) Natural cooling Forced air-cooling (Side mounting) 20 mm min. 3 (1 m /min) 20 mm min. (Side mounting) Natural cooling (Side mounting) Ambient temperature (°C) Ambient temperature (°C) 600-W Model Single Operation Parallel Operation Standard Mounting 120 120 20 mm min. 20 mm min. 100 100 20 mm min. 20 mm min. Ambient temperature (°C) Ambient temperature (°C) Note: Provide a minimum clearance of 20 mm between the Power Supplies. 7 Load (%) Load (%) Load (%) Load (%) Load (%) Load (%) S82J S82J Overload Protection Overheat Protection Function 10- to 300-W Models 600-W Model Only The Power Supply is provided with an overload protection function If the internal temperature of the S82J rises excessively as a result that protects the load and the power supply from possible damage of fan failure or any other reason, the overheat protection circuit will by overcurrent. When the output current rises above 105% to 160% be triggered to protect the internal elements of the S82J and simul- of the rated output current (105% of the rated output current for taneously a protection-ON alarm indicator will be lit. To reset the 300-W models), the protection function is triggered, decreasing the S82J, turn off the input voltage, leave the S82J for at least three min- output voltage. When the output current falls within the rated range, utes, and then apply the input voltage again. the overload protection function is automatically cleared. Inrush Current, Startup Time, Hold 10- to 300-W Models Time (except for 50-W and 50-W and 100 (24 V)-W Models) 100 (24 V)-W Models Input ON Input OFF AC input Rated voltage Rated voltage voltage Inrush current on input application AC input current 96.5% Intermittent 90% operation Output 0 50 100 voltage Startup time Hold time Output current (%) Output current (%) (20 ms min.) 600-W Models If an excessive current flows for 5 s or more, the output will be turned off and simultaneously protection-ON alarm indicator will be lit. To reset the S82J, turn off the input voltage, leave the S82J for at least three minutes, and then apply the input voltage again. Note: Do not continue using the S82J with the output terminals short-circuited or the overcurrent condition continued, otherwise the internal elements of the S82J may be dam- aged or broken. Overvoltage Protection 100 (5, 24 V)-W Models The Power Supply is provided with an overvoltage protection func- tion that protects the load and the Power Supply from possible dam- age by overvoltage. When the output voltage rises above a set val- ue (120% of the rated output voltage), the protection function is trig- gered, shutting off the output voltage. If this occurs, reset the Power Supply by turning it off for 1 minutes min. and then turning it on again. Overvoltage protection operating Rated output voltage Variable range 300- and 600-W Models If a voltage that is 120% of the rated output voltage or above is out- put, the output voltage will be turned off and simultaneously protec- tion-ON alarm indicator will be lit. To reset the S82J, turn off the input voltage, leave the S82J for at least three minutes if it is a 600-W model or at least 90 seconds if it is a 300-W model, and then apply the input voltage again. 8 Output voltage (V) Output voltage (V) Output voltage (V) S82J S82J Operation Block Diagrams S82J-010���� (10 W) S82J-025���� (25 W) Fuse* AC(L) Input Noise filter AC(N) Inrush current Rectifier +V protection circuit DC Output *Fuse capacity: 10 W, 1 A –V 25 W, 2 A Rectifier Drive control circuit Photocoupler Detector S82J-050���� (50 W) Fuse (3 A)* +V AC(L) DC Output Input Noise filter AC(N) –V Rectifier Inrush current Smoothing Rectifier and protection circuit smoothing circuit circuit *Fuse capacity: 3 A Control circuit Overload Overload detection detection circuit circuit Photocoupler S82J-100���� (100 W, 5-/12-/15-V Output) Fuse* AC (L) Input Noise filter AC (N) Inrush current Rectifier +V protection circuit DC Output *Fuse capacity: 5 A –V Rectifier and smoothing circuit Drive control circuit Detector Overcurrent detector Photocoupler Overvoltage detector Overvoltage protection circuit (5 V only) 9 S82J S82J S82J-10024���(100 W, 24-V Output) Fuse (5 A) AC(L) +V DC Output Input Noise filter AC(N) –V Rectifier Inrush current Smoothing Rectifier and protection circuit smoothing circuit circuit Control circuit Overload Detector detection circuit Photocoupler Overload detection circuit Photocoupler S82J-15024���(150 W) Fuse (8 A) AC (L) +V Input DC Output Noise filter AC (N) –V Rectifier and Inrush current Rectifier 100 or 200 V smoothing protection circuit (selected au- circuit tomatically) Control circuit Detector Overcurrent detector Photocoupler S82J-30024� (300 W) Rectifier and Fuse (10 A) smoothing circuit Input DC Output Noise filter Inrush current Rectifier and protection circuit smoothing circuit 100/200 V (selectable) Control circuit Overcurrent Detector detector Photocoupler Overvoltage detector Photocoupler Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is Parallel operation selector 200 to 230 VAC. 10 S82J S82J S82J-60024� (600 W) Fuse Rectifier and 20 A smoothing circuit Noise filter Input DC Output Inrush current Rectifier and protection circuit smoothing circuit 100/200 V (selectable) Fan Control circuit Overcurrent Detector detector Photocoupler Overheat Note: Short-circuit the input voltage selector detector Overvoltage terminals if the input is 100 to 120 VAC. Keep the terminals open if the input is 200 detector to 230 VAC. Photocoupler Parallel operation selector 11 S82J S82J Dimensions Note: All units are in millimeters unless otherwise indicated. Front-mounting Bracket Type 12 max. 90±1 S82J-010��� (10 W) Mounting Holes 3.5 (Surface Screw Mounting) Side Mounting 97±1 65±0.5 Two, M3 5 65±0.5 5 82±0.5 M3.5 terminal Two, 3.5 dia. screw 82±0.5 3.5 dia. 3.5 78±0.5 6.5 Bottom Mounting 35±1 28 Two, M3 17.5 50±0.5 Two, M3 15 For track mounting bracket (4 mm deep max.) 78±0.5 12 max. 124±1 S82J-025��� (25 W) Mounting Holes 3.5 (Surface Screw Mounting) Side Mounting 97±1 Two, M3 65±0.5 6 65±0.5 5 116±0.5 M3.5 terminal Two, 3.5 dia. 116±0.5 screw 3.5 dia. 6.5 112±0.5 3.5 Bottom Mounting Two, M3 40±1 28 17.5 83±0.5 21.5 Two, M3 112±0.5 For track mounting bracket (4 mm deep max.) S82J-050��� (50 W) 12 max. 161±1 Mounting Holes 3.5 Side Mounting Two, M3 97±1 65±0.5 65±0.5 7 5 153±0.5 153±0.5 M3.5 terminal Two, 3.5 dia. screw 3.5 dia. 6.5 150.5±0.5 Bottom Mounting 3.5 20±0.5 Two, M3 40±1 28 20 10 150.5±0.5 127±0.5 22 Three, M3 For track mounting bracket (4 mm deep max.) 12 S82J S82J 12 max. 170±1 S82J-10024� Mounting Holes (100 W, 24-V Output) 4.5 Side Mounting Two, M3 97±1 65±0.5 65±0.5 162±0.5 5 162±0.5 7 M3.5 terminal 4.5 dia. screw Three, M4 Bottom Mounting 6.5 160±0.5 4.5 dia. Two, M3 4.5 25±0.5 50±1 27.5 28±0.5 160±0.5 15 100±0.5 15 198 (see note) S82J-100��� Mounting Holes 188 (100 W, 5-/12-/15-V Output) (Surface Screw Mounting) 4 max. S82J-15024� (150 W) Side Mounting 4.5 Two, M4 8.1 97 89±0.5 9.5 82±0.8 4.5 dia. M4 x 8 180±0.5 3±0.25 7±0.3 180±0.5 Mounting holes (on both sides) 4.5 dia. 178±0.5 3±0.25 Bottom Mounting Two, M4 Note: Top terminal and connector models 25±0.5 are 188 mm wide. 50 4.5 35±0.5 27.5±0.3 15 178±0.5 100±0.5 55±0.3 Three, M4 (6 mm max. deep) Eight, M4 holes S82J-30024� (300 W) (depth: 8 max. Nine, M4 terminal screws 4 max. (19) on both sides) Mounting Holes (Surface Screw Mounting) Side Mounting Side Four, 4.5 dia. 50±0.5 Four, M4 holes (depth: 8 max.) 150±0.5 Bottom Mounting Four, 4.5 dia. 100±0.5 150±0.5 13 S82J S82J S82J-60024� (600 W) Eight, M4 holes (depth: 8 max. on both sides) Mounting Holes (Surface Screw Mounting) Side Mounting Four, 4.5 dia. 50±0.5 Four, M4 holes (depth: 8 max. on one side) Four, M4 holes (depth: 8 max.) 150±0.5 Bottom Mounting Nine, M4 terminal screws Four, 4.5 dia. 100±0.5 150±0.5 Dimensions with Mounting Bracket (Provided) 10-/25-/50-/100 (24 V)-W Models Mounting Holes Using the Mounting Bracket 1.5 11 4.6 Attach the mounting bracket to the panel and 15±0.2 loosely tighten the two screws. Insert the projected 9 parts of the bracket (b) to the square holes of the power supply (a). Then securely tighten the Two, 74 Two, M3 60 60 3.5 dia. screws. 4.6 Note: The mounting screws are order separately. 11 20 5 20 31.5 4.7 (b) 15 t=1.0 (a) 20.5 Power supply unit Mounting bracket (b) (a) 100- (5, 12, 15 V) and 150-W Models Mounting with Brackets Mounting bracket 6.5 11 5 dia. 120 MAX 110±0.5 23.5 1.5 38 t=0.8 Two, 5 dia. 30±0.5 Note: The brackets are for front-mounting. 14 S82J S82J 300-W Models 10 dia. Two, 5 dia. Note: To provide ventilation space, the body will shift forward by 21.6 mm from t= 1.6 the mounting surface. 600-W Models Note: To provide ventilation space, the body will shift forward by 23.6 mm from the mounting surface. 15 S82J S82J DIN Track Mounting Bracket Type S82J-010���D (10 W) 9 max. when slided out S82J-025���D (25 W) 9 max. when slided out S82J-050���D (50 W) 9 max. when slided out S82J-10024�D (100 W, 24-V Output) 9 max. when slided out 16 S82J S82J S82J-100���D (100 W, 5-/12-/15-V Output) S82J-15024�D (150 W) 9 max. when slided out 17 S82J S82J Installation 10-/25-/50-/100-/150-W Models Note: 10-/25-/50-/100 (24 V)-W models are available only as Front Terminal Models. Front Terminals Model Top Terminals Model Connector Model 5 5 5 6 6 6 +V +V +V 1 1 1 –V –V –V 3 GR 3 GR 3 GR AC (L) AC (L) AC (L) 2 2 2 NC AC (N) AC (N) AC (N) 9 Connectors Connector Connector on the PCB side Housing Terminal Input Wafer (Made by Molex) 5277-04A-RE Housing (Made by Molex) 5196-04-RE Terminal (Made by Molex) 5194T or or 5196-04 5194TL Output Tab header (Made by Nippon AMP) Rise housing (Made by Nippon AMP) Rise contact (Made by Nippon AMP) 1-178140-5 1-178129-6 1-175196-5 or 1-175218-5 Note: The permissible current of the output connector is 8 A per pin. 300-W Models 5 6 +V 1 AC (L) 2 +V AC (N) �V 4 Side view �V GR 3 7 8 65 7 1 Side view 600-W Models 8 AC (L) AC (N) 1. DC Output Terminals: Connect the load lines to these terminals. GR 2. Input Terminals: Connect the input lines to these terminals. 4 3 2 Note: A fuse is inserted into the AC (L) side. 3. Ground Terminal (GR): Connect a ground line to this terminal. 4. Input Voltage Selector Terminals: Short-circuit the terminals if the input is 100 to 120 VAC and open the terminals if the input is 200 to 230 VAC 5. Output Indicator (DC ON): Lights while a Direct Current (DC) output is ON. 6. Output Voltage Adjuster (V.ADJ): It is possible to increase or decrease the output voltage by 10%. 7. Protection-ON Alarm Indicator: The red indicator will be lit if the overvoltage (for a 300-/600-W model) or overheat protection (for a 600-W model) circuit is triggered. This indicator will also be lit when overcurrent (for a 600-W model) is detected. 8. Parallel/Single Operation Selector: Set the selector to PARALLEL if the Units are in parallel operation. 9. NC Terminals: Leave unconnected. 18 S82J S82J Precautions 100 (5, 12, 15 V)/150-/300-/600-W Models Mounting (A) Side mounting To improve and maintain the reliability of the Power Supply over a long period of time, adequate consideration must be given to heat (B) Bottom mounting (secured with screws from the inside of the radiation. Switching Power Supply) The Power Supply is designed to radiate heat by means of natural (C) Bottom mounting (secured with screws from the back of the air-flow. Therefore, mount the Power Supply so that air flow takes Switching Power Supply) place around the Power Supply. When mounting the Power Supply, mounting it to a metal plate is recommended. When mounting two or more Power Supplies side-by-side, allow at least 20 mm spacing between them, as shown in the following il- (B) lustration. Forced air-cooling is recommended. (A) Air (C) Metal plate 20 mm min. (D) Front mounting Front mounting is possible with the mounting brackets pro- Mounting Methods vided. Refer to Dimensions. The following mounting methods are available. 10-/25-/50-/100 (24 V)-W Models (A) Side mounting (B) Bottom mounting (C) Front mounting (see Accessories) Mounting brackets (provided) Metal plate 19 S82J S82J With the S82J-050���� or S82J-10024��, if the load is shorted Generating Output Voltage (±) a reverse voltage may result in the Power Supply causing deteriora- An output of ± can be generated by using two Power Supplies as tion and damage. It is recommended that diodes are connected as shown below, because the Power Supply produces a floating out- shown in the previous diagram (D , D ). 1 2 put. Parallel Operation +V Only 300- and 600-W models can be in parallel operation. Do not +V INPUT operate any other models in parallel. The output of the models in –V Load parallel operation is a maximum of 80% of the rated output. Set the parallel operation selector to PARALLEL if the Units are in 0 V parallel operation and make sure that the thickness and the length Load +V of all wires connected to the load are the same to ensure that the INPUT wires will have no voltage drop differences. –V –V Fan Replacement The service life of the fan is approximately 50,000 hours (at 25°C). If operation amplifiers as loads are connected in series, connect a The service life varies, however, depending on the ambient temper- diode between the positive and negative output terminals of each ature or other surrounding environmental conditions such as dust. Switching Power Supplies as shown in the illustration below. With- As a preventive maintenance measure, replace the fan within two out these diodes, the Power Supplies may not start when power is years if it is used at an ambient temperature of 40°C. turned on, possibly damaging internal circuits over a period of time. Fans are available as replacements. Use Schottky barrier diodes with a low forward voltage (V ). Other F types of diodes will not be effective. Guidelines for the dielectric strength and current of the diodes are as follows: Dielectric strength: At least twice the rated output voltage of the Power Supply Forward current: At least twice the rated output current No diodes are required for models that allow series operation. + V INPUT D 1 Load – V Load Load + V Model: S82Y-JFAN D INPUT 2 – V Fan Set: Fan (above), four M4 x 35 sems screws, instruction sheet, and packing case Series Operation Replace the fan as shown in the following illustration. Only models with power ratings of 50/100/150/300/600 W allow se- ries operation. As shown in the following diagram, the output voltage from each Switching Power Supply can be added. D 1 +V INPUT –V Load +V INPUT –V D 2 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. M047-E1-6 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Measuring and Supervisory Controls Department Shiokoji Horikawa, Shimogyo-ku, Printed in Japan Kyoto, 600-8530 Japan Tel: (81)75-344-7108/Fax: (81)75-344-7189 0301-2M (A) 20

Related Products

OMRON AUTOMATION
AC/DC Power Supply Single-OUT 24V 0.5A 10W 5-Pin S82J-01024A
OMRON AUTOMATION
AC/DC Power Supply Single-OUT 24V 4.5A 100W 5-Pin S82J-10024DD
OMRON AUTOMATION
AC/DC Power Supply Single-OUT 24V 10A 240W S82K-24024
OMRON AUTOMATION
AC/DC Power Supply Single-OUT 24V 3.75A 90W 16-Pin S82K-P09024
OMRON AUTOMATION
AC/DC Power Supply Single-OUT 15V 4A 60W S82L-0615
OMRON AUTOMATION
AC/DC Power Supply Single-OUT 24V 2.5A 60W S82L-0624

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Electronics Finder are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Electronics Finder is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.067 seconds.