Electronics Finder chervon right Manufacturers chervon right O chervon right OMRON AUTOMATION chervon right X-10GQ21-B
About product Specifications Datasheet FAQ

OMRON AUTOMATION X-10GQ21-B

Image of OMRON AUTOMATION X-10GQ21-B

Description

Switch Snap Action N.O./N.C. SPDT Cross Roller Plunger Screw 10A 250VDC 5N Panel Mount
X-10GQ21-B

Part Number

X-10GQ21-B

Price

Request Quote

Manufacturer

OMRON AUTOMATION

Lead Time

Request Quote

Category

Switches »  Switch Snap Action

Specifications

Manufacturer

Omron Automation

Manufacturers Part #

X-10GQ21-B

Industry Aliases

X-10GQ21-B

Sub-Category

Snap Action Switches

Factory Pack Quantity

1

Datasheet

pdf file

x_ds_e_4_3_csm570.pdf

1961 KiB

Extracted Text

General-purpose Basic Switch X CSM_X_DS_E_4_3 Direct Current Switch with Built-in Magnetic Blowout • Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. • Same shape and mounting procedures as the Z Basic Switches. Be sure to read Safety Precautions on page 9 and Safety Precautions for All Basic Switches. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Ordering Information Model Number Legend Terminal Solder terminal Screw terminal Actuator Model Model X-10G@-@ (1) (2)(3) (4) Pin plunger X-10G X-10G-B (1) Ratings Slim spring plunger X-10GS X-10GS-B 10 : 10 A (125 VDC) (2) Contact Gap Short spring plunger X-10GD X-10GD-B G : 0.9 mm Panel mount plunger X-10GQ X-10GQ-B (3) Actuator None : Pin plunger D : Short spring plunger Panel mount roller plunger X-10GQ22 X-10GQ22-B S : Slim spring plunger Panel mount cross Q : Panel mount plunger X-10GQ21 X-10GQ21-B roller plunger Q21 : Panel mount cross roller plunger Q22 : Panel mount roller plunger X-10GL X-10GL-B Leaf spring L : Leaf spring W : Hinge lever Short hinge lever X-10GW21 X-10GW21-B W2 : Hinge roller lever W21 : Short hinge lever W22 : Short hinge roller lever Hinge lever X-10GW X-10GW-B W4 : Low-force hinge lever M : Reverse hinge lever X-10GW4 X-10GW4-B Low-force hinge lever M2 : Reverse hinge roller lever M22 : Reverse short hinge roller lever Short hinge roller lever X-10GW22 X-10GW22-B (4) Terminals None : Solder terminal Hinge roller lever X-10GW2 X-10GW2-B B : Screw terminal (with toothed washer) X-10GM X-10GM-B Reverse hinge lever Reverse short hinge X-10GM22 X-10GM22-B roller lever * Reverse hinge roller lever * X-10GM2 X-10GM2-B * The plungers of reverse-type models are continuously pressed by the compression coil springs and the plungers are freed by operating the levers. 1 X Specifications Ratings Contact Specification Non-inductive load (A) Inductive load (A) Material Silver Contacts Rated Resistive Inductive Gap Lamp load Motor load 0.9 mm voltage load load (standard value) NC NO NC NO NC NO NC NO NC 30 A max. Inrush current 8 VDC 10 3 1.5 10 10 5 2.5 NO 15 A max. 14 VDC 10 3 1.5 10 10 5 2.5 30 VDC 10 3 1.5 10 10 5 2.5 Engineering Data 125 VDC 10 3 1.5 7.5 6 5 2.5 Mechanical Durability (X-10G) 250 VDC 3 1.5 0.75 2 1.5 2 1.5 5,000 Note: 1. The above values are for the steady-state current. Ambient temperature: 20±2°C 3,000 2. Inductive load has a power factor of 0.4 min. (AC) and a time constant Ambient humidity: 65±5%RH of 7 ms max. (DC). Without load Operating frequency: 240 operations/min 3. Lamp load has an inrush current of 10 times the steady-state current. 1,000 4. Motor load has an inrush current of 6 times the steady-state current. 700 5. The above electrical ratings also apply to the AC voltage. 500 6. With the reverse-type models (X-10GM@), the normally closed circuits and normally open circuits are reversed. 300 7. The ratings values apply under the following test conditions: 200 (1) Ambient temperature: 20±2°C (2) Ambient humidity: 65±5%RH 100 (3) Operating frequency: 20 operations/min 70 50 Certified Standard Ratings 30 20 Ask your OMRON representative for information on certified models. UL/CSA 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Rated voltage Model X-10G Overtravel (mm) 125 VDC 10 A Electrical Durability (X-10G) 250 VDC 3 A 500 Ambient temperature: 20±2°C EN (CE) (Conform to EN61058-1) 300 Ambient humidity: 65±5%RH 200 Operating frequency: 20 operations/min Rated voltage Model X-10 125 VDC 10 A 100 70 50 Characteristics 125 VDC L/R = 0 30 Operating speed 0.1 mm to 1 m/s *1 20 Mechanical 240 operations/min 125 VDC Operating L/R = 7 ms frequency Electrical 20 operations/min 10 7 Insulation resistance 100 MΩ min. (at 500 VDC) 5 Contact resistance 15 mΩ max. (initial value) 3 1,500 VAC, 50/60 Hz for 1 min between 2 terminals of the same polarity, between Dielectric strength current-carrying metal parts and the ground, 1 021 48610124 and between each terminal and non-current- Switching current (A) carrying metal parts Vibration Malfunction 10 to 55 Hz, 1.5-mm double amplitude *2 resistance 2 Destruction 1,000 m/s max. Shock 2 resistance Malfunction 300 m/s max. *1 *2 Mechanical 1,000,000 operations min. Durability Electrical 100,000 operations min. Degree of protection IP00 Degree of protection Class I against electric shock Proof tracking index (PTI) 175 Ambient operating −25°C to 80°C (with no icing) temperature Ambient operating 35% to 85%RH humidity Weight Approx. 27 to 63 g *1. The values are for the pin plunger models. (Contact your OMRON representative for other models.) *2. Malfunction: 1 ms max. Structure Contact Form (SPDT) (+) COM NC NO Note: With the reverse-type models (X-10GM@), the NC and NO terminal arrangements are reversed. 2 4 4 Durability (x10 operations) Durability (x10 operations) X Dimensions (Unit: mm) Terminals Mounting Use M4 mounting screws with plane washers or spring washers Screw Terminals (-B) to securely mount the Switch. Tighten the screws to a torque of 1.18 to 1.47 N·m. Two, 4.2-dia. mounting 9.2 holes or M4 screw holes 20 20 ±0.2 17.45 ±0.1 25.4 COM NO NC The Switch can be panel mounted, provided that the hexagonal Three, M4 × 5.5 Terminal screws 13 2 nut of the actuator is tightened to a torque of 2.94 to 4.9 N·m. (with toothed 49.2 washer) Panel Mount Plunger Panel Mount Roller Plunger Solder Terminal (-A) ("-A" is not included in the model numbers.) +0.2 +0.2 12.5 dia. 12.5 dia. 0 0 +0.2 5 0 6.4 +0.2 ±0.1 25.4 13 0 11.9 ±0.2 17.45 3 1 NO COM NC 2 49.2 Note: 1. Tighten the terminal screws to a torque of 0.78 to 1.18 N·m. 2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 3. In case of DC voltage, set the COM to the positive terminal. 3 X Dimensions and Operating Characteristics The models, illustrations, and graphics are for screw-terminal models. (The dimensions for models that are omitted here are the same as for pin-plunger models.) Pin Plunger Slim Spring Plunger X-10G-B X-10GS-B 5.2 dia. PT 23.3±0.25 4 dia. 2.3 dia. *1 PT ±0.25 +0.075 2.3SR *1 23.3 4.2 dia. hole -0.025 *2 *2 OP OP 24.2 9 dia. 24.2 9.2 +0.075 4.2 -0.025 +0.1 4.36 dia. -0.05 ±0.2 17.45 11.9 25.4±0.1 *1. Stainless-steel pin plunger (flat, 1R chamfering) *1. Stainless-steel pin plunger *2. Three vent holes 49.2 *2. Three vent holes Short Spring Plunger Panel Mount Plunger X-10GD-B X-10GQ-B 8.35 dia. PT ±0.25 23.3 12.3 dia. M12 × 1 mounting screw 11.9SR *1 Two hexagonal nuts 10 dia. (2 t × 14 width PT ±0.25 23.3 7.15 dia. OP across flats) *3 12SR *1 13.1 *2 Two lock nuts (2 t × 15.6 width OP across flats) 16 dia. 16.3 *2 24.2 *1. Stainless-steel pin plunger *1. Plated iron plunger *2. Three vent holes *2. Three vent holes *3. Incomplete screw part with a maximum length of 1.5 mm Note: Do not use both the M12 mounting screw and the mounting holes in the case at the same time. Doing so will cause stress to be applied to the Switch, possibly damaging the case or cover. Panel Mount Roller Plunger Panel Mount Cross Roller Plunger X-10GQ22-B X-10GQ21-B 12.7 dia. × 4.8 *1 12.7 dia. × 4.8 *1 PT ±0.25 PT 23.3±0.25 23.3 M12 × 1 mounting screw M12 × 1 mounting screw Two hexagonal nuts Two hexagonal nuts OP OP (3 t × 17 width (3 t × 17 width across flats) across flats) 15.5 15.5 *3 *3 *2 *2 16 dia. 16 dia. 16.3 16.3 *1. Stainless-steel roller *1. Stainless-steel roller *2. Three vent holes *2. Three vent holes *3. Incomplete screw part with a maximum length of 1.5 mm. *3. Incomplete screw part with a maximum length of 1.5 mm. Note: Do not use both the M12 mounting screw and the mounting holes in the Note: Do not use both the M12 mounting screw and the mounting holes in the case at the same time. Doing so will cause stress to be applied to the case at the same time. Doing so will cause stress to be applied to the Switch, possibly damaging the case or cover. Switch, possibly damaging the case or cover. Leaf Spring t = 0.3 *1 X-10GL-B 4.8 ±0.8 49.6 *2 FP OP *1. Stainless-steel spring lever *2. Three vent holes Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Operating Characteristics Model X-10G-B X-10GS-B X-10GD-B X-10GQ-B X-10GQ22-B X-10GQ21-B X-10GL-B Operating force OF max. 5.00 N 5.00 N 5.00 N 5.00 N 5.00 N 5.00 N 1.96 N Release force RF min. 1.12 N 1.12 N 1.12 N 1.12 N 1.12 N 1.12 N 0.14 N Pretravel PT max. 0.9 mm 0.9 mm 0.9 mm 0.9 mm 0.9 mm 0.9 mm − Overtravel OT min. 0.13 mm 1.6 mm 1.6 mm 5.5 mm 3.6 mm 3.6 mm 1.6 mm * Movement Differential MD max. 0.18 mm 0.18 mm 0.18 mm 0.18 mm 0.18 mm 0.18 mm 2.3 mm Free Position FP max. − − − − − − 22.1 mm Operating Position OP 15.9±0.4 mm 28.2±0.5 mm 21.2±0.5 mm 21.8±0.8 mm 33.4±1.2 mm 33.4±1.2 mm 17.4±0.8 mm * Be sure to use the switch at the rated OT value of 1.6 mm. 4 X Short Hinge Lever Hinge Lever X-10GW21-B X-10GW-B t = 1 *1 26.2 4.9 t = 1 *1 4.9 26.2 *2 *2 FP FP OP 20.2 17.4 20.2 OP 14.4 17.4 14.4 9.2 +0.075 4.2 -0.025 +0.075 4.2 dia. holes -0.025 +0.1 4.36 dia. -0.05 ±0.2 17.45 *1. Stainless-steel lever 11.9 ±0.1 *2. Three vent holes 25.4 *1. Stainless-steel lever 49.2 *2. Three vent holes Low-force Hinge Lever Short Hinge Roller Lever X-10GW4-B X-10GW22-B 9.5 dia. × 4 t = 1 *1 plastic roller 26.2 t = 1 *1 4.9 26.2 PT *2 *2 FP OP OP 20.2 20.2 17.4 17.4 14.4 14.4 *1. Stainless-steel lever *1. Stainless-steel spring lever *2. Three vent holes *2. Three vent holes Hinge Roller Lever Reverse Hinge Lever X-10GW2-B X-10GM-B 9.5 dia. × 4 plastic roller 26.2 t = 1 *1 *1 4.9 t = 1 18.65 *2 *2 FP OP FP 20.2 OP 20.2 17.4 17.4 14.4 14.4 *1. Stainless-steel lever *1. Stainless-steel lever *2. Three vent holes *2. Three vent holes Reverse Short Hinge Lever Reverse Hinge Roller Lever X-10GM22-B X-10GM2-B 9.5 dia. × 4 t = 1*1 plastic roller 9.5 dia. × 4 18.65 plastic roller 18.65 *1 *2 *2 t = 1 FP OP FP OP 20.2 17.4 14.4 20.2 17.4 14.4 *1. Stainless-steel lever *2. Three vent holes *1. Stainless-steel lever *2. Three vent holes Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Model Operating X-10GW21-B X-10GW-B X-10GW4-B X-10GW22-B X-10GW2-B X-10GM-B X-10GM22-B X-10GM2-B Characteristics OF max. 2.45 N 1.08 N 0.25 N 2.16 N 1.42 N 2.16 N 6.86 N 3.14 N RF min. 0.31 N 0.14 N 0.05 N 0.34 N 0.21 N 0.25 N 1.52 N 0.49 N PT max. − − 14.3 mm − − − − − OT min. 2.1 mm 4.8 mm 4.8 mm 2.4 mm 4 mm 5.5 mm 2 mm 4 mm MD max. 1.7 mm 3.9 mm 3.9 mm 1.7 mm 3 mm 2.1 mm 0.75 mm 1.5 mm FP max. 25.5 mm 34.6 mm − 37.1 mm 40.5 mm 26.8 mm 36.1 mm 37.4 mm OP 20.7±0.8 mm 21.1±0.8 mm 21.1±0.8 mm 32.2±0.8 mm 32.2±0.8 mm 21.1±0.8 mm 32.2±0.8 mm 32.2±0.8 mm 5 63.5R 63.5R 56R 28.2R 48.5R 40.6R 26.6R 18.5R X Accessories (Order separately) A Terminal Protective Cover, Actuators, and a Separator are available. Terminal Covers (Sold Separately) Separator (Sold Separately) The Terminal Covers can be attached to Z, A, X, and DZ Switches. Use a Separator when it is difficult to The Terminal Cover is secured with mounting screws and protects the casing and terminal wires provide a sufficient insulation distance or from dust, vibration, or fingers, thus preventing terminal short-circuiting, ground faults, wire when using the Switch near metal parts or disconnection or improper connection, and electric shock accidents. copper wires. Terminal Covers made of phenol resin have five or six thin wall sections. These sections can be Operation Information torn open for providing holes for lead cables at desired points. A terminal cover can’t be used in the case of using an actuator sold separately. Model SEPARATOR FOR Z Operation Information Application Soldering terminal use Screw terminal use Remarks Material Mounting direction Model Phenol resin Side mounting AP-A AP-B --- Metal press mold Side mounting AP1-A AP1-B Used for AP-A and AP-B Vinyl chloride Side mounting AP-Z --- Note: Use a Terminal Cover for screw terminals fir DZ-series Switches with soldering terminals. Dimensions (Unit: mm) Terminal Covers AP-A AP-B 52.8 53.8 +0.2 +0.2 25.4 +0.2 +0.2 Soldering Terminal Use 4.3 4.3 25.4 Screw Terminal Use 4.3 4.3 0 0 0 0 (Phenol Resin) (Phenol Resin) 8 8 16.3 20.2 2.15R 2.15R 6.5 6.5 8 21 8 21 Note: The Cover has five thin, easy-to-separate Note: The Cover has six thin, easy-to-separate portions for easy lead wire connections. portions for easy lead wire connections. AP1-A AP1-B 54.4 55.4 +0.2 +0.2 +0.2 +0.2 25.4 Screw Terminal Use 25.4 Soldering Terminal Use 4.3 4.3 4.3 4.3 0 0 0 0 (Metal Press Mold) (Metal Press Mold) 8 8 17.1 21 2.15R 2.15R 7.2 7 8.5 22.6 8.5 22.6 Note: The Cover has five holes for easy lead wire connections. Note: The Cover has six holes for easy lead wire connections. Two, 4.2 dia. AP-Z Pressure plate (t1 steel) 52.8 Soldering or Screw Terminal Use 21 25.4 Cable Pull-out Dimension (Vinyl Chloride) 7 14 A-A' cross-section B-B' cross-section 21 15 8 dia. 13 6 dia. 39 46 Note: A 6-dia. or 8-dia. cable can be A A' used by cutting the cable pull-out hole to the size of the cable to be B B' used. 13 M3 × 20 Phillips screw 12 Nut (with plane washer and nut) 15 Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified. (±0.8 mm for the AP-Z) Separator Two, 4.5 dia. 13.5 27±0.5 Note: 1. Each dimension has a tolerance of ±0.4 mm unless otherwise specified. 2. The material is EAVTC (Epoxide Alkyd Varnished Tetron Cloth) and its heat-resisting 11.9 25.4±0.2 temperature is 130°C. t = 0.51 49.2±0.5 6 X Actuators (Sold Separately) A Switch can be actuated by a cam or an appropriate object, in which case, use one of the following Actuators according to the application. Ordering Information Actuator Application Common to Z and X models Hinge lever XAA-1 Hinge roller lever ZAA-2 Short ZAQ-3 Panel mount plunger Medium ZAQ-2 Long ZAQ-1 Panel mount roller plunger ZAQ-22 Dimensions (Unit: mm) and Operating Characteristics Note: These Actuators are not provided with Switches. Two, M4 30 Two, M4 Hinge Lever XAA-1 Model Z-15G-B X-10G-B Operating characteristics 19.1 Operating force OF max. 4.90 N 4.90 N Release force RF min. 1.67 N 1.67 N Overtravel OT min. 12.7 mm 12.7 mm * Movement Differential MD max. 2.2 mm 3.3 mm 7 Free Position FP max. 32.9±1.6 mm Operating Position OP 28.9±1.6 mm FP OP 29.4 Note: This Actuator can be used with the Z-15G(-B) and X- 38.5 20.5 10G(-B). When mounting the Switch, set the overtravel to between 32% and 100%, taking into consideration the operating body and the distance between the Actuator and the dog. * Stainless steel 11.9 25.4±0.1 49.2 Two, M4 30 Two, M4 Hinge Roller Lever ZAA-2 Z-15G-B X-10G-B 19.1 OF max. 4.90 N 4.90 N RF min. 1.67 N 1.67 N OT min. 12.7 mm 12.7 mm 22.2 9.5 dia. × 4.8 *1 MD max. 2.2 mm 3.3 mm FP max. 44.5±1.6 mm *2 OP 40.4±1.6 mm 7 Note: This Actuator can be used with the Z-15G(- B) and ZX-10G(-B). When mounting the FP OP Switch, set the overtravel to between 32% 29.4 and 100%, taking into consideration the 38.5 20.5 operating body and the distance between the Actuator and the dog. *1. Stainless steel roller 11.9 *2. Stainless steel 25.4±0.1 49.2 Short Panel Mount Plunger 7.9 dia. 23.3 ZAQ-3 M12 × 1 mounting ZAQ-3 12SR PT screw Z-15E-B X-10G-B *1 2 t × 14 width OF max. 8.34 N 5.39 N across flats OP RF min. 1.12 N 1.12 N *3 17.5 14.5 PT max. 0.8 mm 1 mm 1.6 2 t × 15.6 width dia. OT min. 4.8 mm 4.5 mm across flats MD max. 0.15 mm 0.2 mm Two, M4 nuts 20.7 OP 27.8±1.5 mm 24.2 22.6 Note: 1. This Actuator (pin plunger) can be used with Standard Pin Plungers (Z-15G(-B), *3 Z-15E(-B), X-10G(-B), DZ-10G-1A(-1B)) *2 13.5 for the Z, X, and DZ models. Two, M4 × 25 screws 25.4±0.1 20.7 *1. Stainless-steel pin plunger 52.4 *2. Bronze frame *3. Incomplete screw section part with a maximum of 1.5 mm Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified. 7 60R 58.5R XAA-1 XAA-1 X Medium Panel Mount Plunger 7.9 dia. PT 23.3 ZAQ-2 12SR M12 × 1 mounting screw *1 ZAQ-2 Z-15E-B X-10G-B 2 t × 14 width across flats OF max. 8.34 N 5.39 N RF min. 1.12 N 1.12 N OP PT max. 0.8 mm 1 mm 42.8 OT min. 4.8 mm 4.5 mm 2 t × 15.6 width MD max. 0.15 mm 0.2 mm across flats 14.5 *3 1.6 dia. OP 53.2±1.5 mm Note: This Actuator (pin plunger) can be used with Two, M4 × 25 screws Standard Pin Plungers (Z-15G(-B), Z-15E(- 20.7 24.2 22.6 B), X-10G(-B), DZ-10G-1A(-1B)) for the Z, X, and DZ models. *2 13.5 Two, M4 nuts 25.4±0.1 20.7 *1. Stainless-steel pin plunger 52.4 *2. Copper alloy frame *3. Incomplete screw section part with a maximum of 1.5 mm Long Panel Mount Plunger 7.9 dia. PT 23.3 ZAQ-1 12SR *1 ZAQ-1 Z-15E-B X-10G-B M12 × 1 mounting screw OF max. 8.34 N 5.39 N RF min. 1.12 N 1.12 N 2 t × 14 width across flats PT max. 0.8 mm 1 mm OP OT min. 20.6 mm 20.4 mm MD max. 0.15 mm 0.2 mm 42.8 OP 69.1±1.5 mm 2 t × 15.6 width across flats Note: This Actuator (pin plunger) can be used with 14.5 *3 1.6 dia. Standard Pin Plungers (Z-15G(-B), Z-15E(- B), X-10G(-B), DZ-10G-1A(-1B)) for the Z, Two, M4 × 25 screws X, and DZ models. 20.7 24.2 22.6 *2 13.5 Two, M4 nuts 25.4±0.1 20.7 *1. Stainless-steel pin plunger 52.4 *2. Copper alloy frame *3. Incomplete screw section part with a maximum of 1.5 mm Panel Mount Roller Plunger 48 12.7 dia. *1 PT 23.3±0.25 4.8 ZAQ-22 Two hex nuts 5-mm ZAQ-22 thickness, 19 mm Z-15E-B DZ-10G-1B between opposing edges With groove for roller OF max. 8.34 N 11.1 N penetration OP RF min. 1.12 N 1.12 N M12 × 1 mounting PT max. 2 mm 2 mm *3 18.9 1.6 screw OT min. 3.58 mm 1 mm 14.5 dia. MD max. 0.15 mm 0.46 mm OP 37±0.8 mm 35.4±1.2 mm 20.7 23.9 Note: This Actuator (roller plunger) can be used with standard pin plungers (Z-15G(-B), Z-15E(-B), and DZ-10G-1A(-1B)). It cannot be used with X models. Two, M4 × 25 Spring washer *2 25.4±0.2 20.7 screws 11.9 49.2 *1. Stainless-steel pin plunger *2. Steel frame *3. Incomplete screw section part with a maximum of 1.5 mm Note: Each dimension has a tolerance of ±0.4 mm unless otherwise specified. 8 X Safety Precautions Refer to Safety Precautions for All Basic Switches. • Mount a cover if the switch is to be installed in a location where Precautions for Safe Use worker inattention could result in incorrect operation or accidents. Terminal Connection Correct Incorrect When soldering lead wires to the Switch, make sure that the capacity of the soldering iron is 60 W maximum. Do not take more than 5 s to solder any part of the Switch. The characteristics of the Switch will deteriorate if a soldering iron with a capacity of more than 60 W is (preventing malfunctions) applied to any part of the Switch for 5 s or more. • Subjecting the switch to continuous vibration or shock may result in Operation contact failure or faulty operation due to abrasion powder and in • Make sure that the switching frequency or speed is within the reduced durability. Excessive vibration or shock will cause the specified range. contacts to operate malfunction or become damaged. Mount the 1.If the switching speed is extremely slow, the contact may not be switch in a location that is not subject to vibration or shock and in a switched smoothly, which may result in a contact failure or direction that does not subject the switch to resonance. contact welding. • If silver contacts are used with relatively low frequency for a long 2.If the switching speed is extremely fast, switching shock may time or are used with microloads, the sulfide coating produced on damage the Switch soon. If the switching frequency is too high, the contact surface will not be broken down and contact faults will the contact may not catch up with the speed. result. Use a microload switch that uses gold contacts. The rated permissible switching speed and frequency indicate the • Do not use the switch in atmospheres with high humidity or heat or in switching reliability of the Switch. harmful gases, such as sulfide gas (H2S, SO2), ammonia gas (NH3), The life of a Switch is determined at the specified switching speed. nitric acid gas (HNO3), or chlorine gas (Cl2). Doing so may impair The life varies with the switching speed and frequency even when functionality, such as with damage due to contacting faults or corrosion. they are within the permissible ranges. In order to determine the • The switch includes contacts. If the switch is used in an atmosphere life of a Switch model to be applied to a particular use, it is best to with silicon gas, arc energy may cause silicon oxide (SiO2) to conduct an appropriate durability test on some samples of the accumulate on the contacts and result in contact failure. If there is model under actual conditions. silicon oil, silicon filling, silicon wiring, or other silicon products in the • Make sure that the actuator travel does not exceed the permissible OT vicinity of the switch, use a contact protection circuit to limit arcing position. The operating stroke must be set to 70% to 100% of the rated OT. and remove the source of the silicon gas. Handling Precautions for Correct Use • Set the common (COM) terminal to the positive terminal. If it is set to the negative terminal, the Switch will not turn OFF. Mounting Location • Do not use the switch alone in atmospheres such as flammable or • When using the Switch under an inductive load, the arc explosive gases. Arcing and heat generation associated with suppression capability varies depending on current. If the current switching may cause fires or explosions. becomes 0.6 to 1.2 A or of the time constant L/R exceeds 7 ms, be • Switches are generally not constructed with resistance against sure to provide an arc suppressor. water. Use a protective cover to prevent direct spraying if the switch • Since the Switch incorporates a permanent magnet, attention must is used in locations subject to splashing or spurting oil or water, dust be paid to the following points: adhering. (a) Avoid mounting the Switch directly onto a magnetic substance. Incorrect Correct (b) Do not subject the Switch to severe shocks. (c) Avoid placing the Switch in a strong magnetic field. (d) Be sure to prevent iron dust or iron chips from adhering to the built-in magnet or the magnetic blowout function of the Switch will be adversely affected. Terminal box Terminal box (e) Do not apply thermal shock to the Switch, or the magnetic flux will be diminished. • Install the switch in a location that is not directly subject to debris • Since a ventilation hole is provided to avoid abnormal corrosion due and dust from cutting. The actuator and the switch body must be to operating conditions, provide a dustproofing device in locations protected from accumulated cutting debris and dirt. where the Switch is exposed to dust. Incorrect Correct • Do not change operating positions for the actuator. Changing the position may cause malfunction. Wiring • Use wire sizes that are suitable to the applied voltage and carried current. • If you use a soldering iron to solder the wires, do not allow the tip of • Do not use the switch in locations subject to hot water (greater than the soldering iron to exceed 380°C. If a Switch is used with 60°C) or in water vapor. insufficient soldering, abnormal heat and burning may occur. • Do not use the switch outside the specified temperature and atmospheric conditions. • Solder for no more than 5 s at 350°C and for no more than 3 s at The permissible ambient temperature depends on the model. (Refer to the 380°C. If heat is applied for too long, the case may melt, the lead specifications in this catalog.) Sudden thermal changes may cause thermal wire coverings may be scorched, and other characteristics of the shock to distort the switch and result in faults. Switch may deteriorate. Incorrect Correct Panel-mounted Model (X-10GQ@) Separate the installation lo- cation from • To side-mount the panel-mount Switch to the panel with screws, heat sources. remove the hexagonal nut from the actuator. • Too large a dog angle and too fast operating speed may damage the Switch when the Switch is side-mounted on the panel. • Too fast operating speed and too long overtravel of the roller plunger Switch may result in damage to the Switch. 9 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.3 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the X-10GQ21-B?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Switch Snap Action N.O./N.C. SPDT Pin Plunger Solder 20A 500VAC 250VDC 6.13N Screw Mount A-20G

product

Switch Snap Action N.O./N.C. SPDT Pin Plunger Screw 20A 500VAC 250VDC 6.13N Screw Mount A-20G-B

product

Switch Snap Action N.O./N.C. SPDT Pin Plunger Screw 20A 480VAC 250VDC 1491.4VA 6.12N Screw Mount A-2...

product

Switch Snap Action N.O./N.C. SPDT Short Spring Plunger Solder 20A 500VAC 250VDC 6.13N Screw Mount A-...

product

Switch Snap Action N.O./N.C. SPDT Short Spring Plunger Screw 20A 500VAC 250VDC 6.13N Screw Mount A-2...

product

Switch Snap Action N.O./N.C. SPDT Short Spring Plunger Screw 20A 480VAC 250VDC 1491.4VA 6.12N Screw ...