Signal Relay 12VDC 2A DPDT( (14.8mm 7.3mm 9.2mm)) SMD
G6SU-2GDC12

Part Number

G6SU-2GDC12

Price

Request Quote

Manufacturer

OMRON ELECTRONIC COMPONENTS

Lead Time

Request Quote

Category

Relays and I/O Modules »  Signal Relay

Specifications

Manufacturer

Omron Electronic Components

Manufacturers Part #

G6SU-2GDC12

Industry Aliases

G6SU2GDC12

Sub-Category

Signal Relays

Packaging

Tube

Factory Pack Quantity

50

Datasheet

pdf file

en-g6s.pdf

1816 KiB

Extracted Text

G6S Surface-mounting Relay Compact, Industry-Standard 2-pole relay, designed to switch 2A Signal Loads. • Long terminals for ideal for soldering and mounting reliability. (Surface mounting terminal models) • Space-saving inside-L terminal. (Surface mounting terminal models) • Unique terminal structure, designed to withstand IRS soldering processes. (Surface mounting terminal models) • High dielectric strength (2,000 VAC) and impulse withstand voltage between coil and contacts (2,500 V, 2 × 10 μs: Telcordia requirements). • Ultra-miniature at 9.4 mm (H) × 7.5 mm (W) × 15 mm (L). • Models available with BSI (EN62368-1) supplementary insulation certification. (-Y type) RoHS Compliant ■Model Number Legend ■Application Examples • Telecommunication equipment G6S@-@@-@ • Measurement devices 123 4 G • Office automation machines 1. Relay Function 3. Terminal Shape 6 • Audio-visual products. S None : Single-side stable None : PCB terminals • Security equipment U : Single-winding latching F : Outside-L surface mounting terminals • Building automation equipment K : Double-winding latching G : Inside-L surface mounting terminals • Industrial equipment 2. Number of poles/ 4. Approved Standards Contact form • Amusement equipment None : UL, CSA 2: 2-pole/DPDT (2c) • Home appliances Y : UL, CSA, BSI (EN62368-1) ■Ordering Information Surface mounting terminal standard models Packing Tube Packing Tape Packing Rated coil Minimum Rated coil Minimum Minimum ordering unit Enclosure rating Relay Function Contact form Model voltage packing unit Model voltage packing unit (tape packing) 3 VDC 3 VDC 4.5 VDC 4.5 VDC G6S-2F G6S-2F-TR 5 VDC 5 VDC G6S-2G G6S-2G-TR 12 VDC 12 VDC Single-side stable 24 VDC 24 VDC 5 VDC 5 VDC G6S-2F-Y G6S-2F-Y-TR 12 VDC 12 VDC G6S-2G-Y G6S-2G-Y-TR 24 VDC 24 VDC 3 VDC 3 VDC 4.5 VDC 4.5 VDC G6SU-2F G6SU-2F-TR Fully sealed DPDT (2c) 5 VDC 50 pcs/tube 5 VDC 400 pcs/reel 800 pcs/2 reels G6SU-2G G6SU-2G-TR 12 VDC 12 VDC Single-winding latching 24 VDC 24 VDC 5 VDC 5 VDC G6SU-2F-Y G6SU-2F-Y-TR 12 VDC 12 VDC G6SU-2G-Y G6SU-2G-Y-TR 24 VDC 24 VDC 3 VDC 3 VDC 4.5 VDC 4.5 VDC Double-winding G6SK-2F G6SK-2F-TR 5 VDC 5 VDC latching G6SK-2G G6SK-2G-TR 12 VDC 12 VDC 24 VDC 24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. Note 2.When ordering tape packing, add -TR" to the model number. Be sure since -TR" is n ot part of the relay model number, it is not marked on the relay case. Note 3.When ordering tape packing, minimum order unit is 2 reels (400 pcs × 2 = 800 pcs). Note 4.Surface mounting terminal (SMT) standard models are shipped in moisture-proof package. 1 G6S Surface-mounting Relay ●PCB Terminal Standard Models Relay Function Single-side stable Single-winding latching Double-winding latching Minimum Enclosure packing unit rating Contact form Model Rated coil voltage Model Rated coil voltage Model Rated coil voltage 3 VDC 3 VDC 3 VDC 4.5 VDC 4.5 VDC 4.5 VDC G6S-2 5 VDC G6SU-2 5 VDC G6SK-2 5 VDC 12 VDC 12 VDC 12 VDC Fully sealed DPDT (2c) 50 pcs/tube 24 VDC 24 VDC 24 VDC 5 VDC 5 VDC G6S-2-Y 12 VDC G6SU-2-Y 12 VDC −− 24 VDC 24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2 DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC. Note 2.PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package. ■Ratings ●Single-side Stable Model ●Contacts Item Rated Coil Must Power Item Load Resistive load Must release Max. current resistance operate consumption voltage (V) voltage (V) Contact type Bifurcated crossbar Model Rated voltage (mA) (Ω) voltage (V) (mW) Contact material Ag (Au-Alloy) 346.7 64.3 0.5 A at 125 VAC; 4.5 31 145 200% Rated load G Approx. 140 G6S-2 2 A at 30 VDC (at 23°C) 5 28.1 178 6 G6S-2F DC 75% max. 10% min. Rated carry 12 11.7 1,028 2 A S G6S-2G current 170% 24 8.3 2,880 Approx. 200 Max. switching (at 23°C) 250 VAC, 220 VDC voltage 540 125 G6S-2-Y Approx. 200 170% Max. switching G6S-2F-Y DC 12 16.7 720 75% max. 10% min. 2 A (at 23°C) current G6S-2G-Y 24 9.6 2,504 Approx. 230 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. ●Single-winding Latching Model Item Rated Coil Must Power Must release Max. current resistance operate consumption voltage (V) voltage (V) Model Rated voltage (mA) (Ω) voltage (V) (mW) 333.3 90 4.5 22.2 203 G6SU-2 Approx. 100 180% G6SU-2F DC 520 250 75% max. 75% max. (at 23°C) G6SU-2G 12 8.3 1,440 24 6.3 3,840 Approx. 150 5 28.1 178 G6SU-2-Y 200% G6SU-2F-Y DC 12 11.7 1,028 75% max. 75% max. Approx. 140 (at 23°C) G6SU-2G-Y 24 5.8 4,114 Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. ●Double-winding Latching Model Item Rated Coil Must Power Must release Max. current resistance operate consumption voltage (V) voltage (V) Model Rated voltage (mA) (Ω) voltage (V) (mW) 366.6 45 4.5 44.4 101 170% Approx. 200 G6SK-2 (at 23°C) 540 125 G6SK-2F DC 75% max. 75% max. 12 16.7 720 G6SK-2G 140% 24 12.5 1,920 Approx. 300 (at 23°C) Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2.Operating characteristics are measured at a coil temperature of 23°C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. 2 G6S Surface-mounting Relay ■Characteristics Single-winding Latching Single-side Stable Single-winding Latching Double-winding Latching Single-side Stable G6SU-2-Y, Item Relay Function G6S-2, G6S-2F, G6SU-2, G6SU-2F, G6SK-2, G6SK-2F, G6S-2F-Y, G6S-2G-Y, G6SU-2F-Y, G6S-2G G6SU-2G G6SK-2G G6S-2-Y G6SU-2G-Y Contact resistance *1 75 mΩ max. Operate (set) time 4 ms max. Release (reset) time 4 ms max. Min. set/reset pulse width − 10 ms − 10 ms Insulation resistance *2 1,000 MΩ min. (at 500 VDC) 1,000 VAC, 50/60 Hz Between coil and contacts 2,000 VAC, 50/60 Hz for 1 min 2,000 VAC, 50/60 Hz for 1 min for 1 min Dielectric Between contacts of different polarity 1,500 VAC, 50/60 Hz for 1 min strength Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min 500 VAC, 50/60 Hz Between set and reset coil − − for 1 min Insulation Between coil and contacts Clearance: 1 mm, Creepage: 1.5 mm Clearance: 2 mm, Creepage: 2 mm distance 1,500 V (10 × 160 2,500 V (2 × 10 μs); Between coil and contacts 2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs) Impulse μs) 1,500 V (10 × 160 μs) withstand Between contacts of different polarity 2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs) voltage Between contacts of the same polarity 1,500 V (10 × 160 μs) Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) Vibration resistance Malfunction 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) 2 Destruction 1,000 m/s Shock 2 resistance Malfunction 750 m/s Mechanical 100,000,000 operations min. (at 36,000 operations/hr) Durability 100,000 operations min. for AC (at 1,800 operations/h with rated load) Electrical 100,000 operations min. for DC (at 1,200 operations/h with rated load) Failure rate (P level) (reference value) *3 10 μA at 10 m VDC G -40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation) 6 Ambient operating temperature only for double-winding latching 24 VDC and -Y type 24 VDC S Ambient operating humidity 5% to 85% Weight Approx. 2 g Note: The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. *2. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength (except between the set and reset coil). *3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary, depending on switching frequency, operating conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions. ■Engineering Data ●Ambient Temperature ●Ambient Temperature ●Maximum Switching ●Durability vs. Maximum Voltage vs. Maximum Voltage Capacity G6S-2F(G) (Single-side Stable) (Latching) 10 500 250 250 250 G6S 7 300 4.5 to 12 VDC G6SU 5 200 200 200 30 VDC resistive load 3 100 Ambient temperature 23°C Switching frequency: 1,200 operations/h 50 150 150 150 AC resistive load 30 G6SK 1 12 VDC max. 0.7 G6S G6SK 100 100 100 10 24 VDC 24 VDC 0.5 G6S-Y G6S-Y DC resistive load 12 VDC max. 24 VDC 5 125 VAC resistive load 0.3 Ambient temperature 23°C 50 50 50 3 Switching frequency: 1,800 operations/h 0.1 1 0 0 0 10 30 50 70 100 300 500 700 1,000 −40 −20 0 20 40 60 80 100 −40 −20 0 20 40 60 80 100 0 0.5 1 1.5 2 2.5 3 Switching voltage (V) Switching current (A) Ambient temperature (°C) Ambient temperature (°C) Note: “Maximum voltage” is the maximum voltage that can be applied to the Relay coil. ●Ambient Temperature ●Ambient Temperature ●Ambient Temperature vs. Must Operate or Must vs. Switching Current vs. Switching Current Release Voltage ●Shock Malfunction (Single-side Stable) (Latching) G6S-2F(G) G6S-2F(G) 3 3 100 Y Sample: G6S-2F 1,000 Energized Number of Relays: 10 pcs 800 max. 80 600 X G6SU 12 VDC max. X Z De- 1,000 1,000 G6S 400 2 2 min. energized 12 VDC max. G6SU 24 VDC 60 200 G6SK 12 VDC max. G6S-Y 200 24 VDC 40 400 max. 1 1 1,000 1,000 X Z' 600 X' min. G6S 20 800 24 VDC G6SK 24 VDC Shock direction G6S-Y XX' Must operate voltage 1,000 2 12 VDC max. Y Must release voltage Y' Unit: m/s Z 0 0 0 Sample: G6S-2F 40 50 60 70 80 90 100 40 50 60 70 80 90 100 −60 −40 −20 0 20 40 60 80 100 120 Z' Number of Relays: 10 pcs Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) Y' Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. 3 Switching current (A) Switching current (A) 4 Switching current (A) Durability (×10 operations) On the basis of rated voltage (%) Maximum voltage (%) Maximum voltage (%) G6S Surface-mounting Relay ●Electrical Endurance ●Electrical Endurance (with Must Operate and ●Electrical Endurance (with Must Operate and ●Electrical Endurance Must Release Voltage) *1 (Contact Resistance) *1 Must Release Voltage) *1 (Contact Resistance) *1 G6S-2F(G) G6S-2F(G) G6S-2F(G) G6S-2F(G) 100 1,000 100 1,000 Sample: G6S-2F Sample: G6S-2F Sample: G6S-2F Sample: G6S-2F NO contact Number of Relays: 10 pcs Number of Relays: 10 pcs Number of Relays: 10 pcs Number of Relays: 10 pcs Measurement conditions: NO contact - wire-spring Test conditions: 2A resistive load Measurement conditions: NO contact - wire-spring Test conditions: 2A resistive load at NC contact 500 500 relay load at 48 VDC, 120mA (with ARC-killer) 30-VDC with an operation rate of 50% at 30-VDC with an operation rate relay load at 48 VDC, 120mA (with ARC-killer) 80 80 NC contact - resistive load at 48 VDC, 60mA of 50% NC contact - resistive load at 48 VDC, 60mA Switching frequency: 1,200 operations/h Switching frequency: 3,600 operations/h 300 300 Switching frequency: 3,600 operations/h Switching frequency: 1,200 max. operations/h max. 60 60 min. Must operate voltage min. Must operate voltage 100 100 40 40 Contact resistance 50 50 max. Contact resistance max. max. min. max. max. max. min. Must release voltage 30 30 min. min. min. Must release voltage min. 20 20 NO contact NC contact 10 0 10 0 50 100 300 500 1,000 5,000 50 100 300 500 1,000 5,000 1 3 5 10 30 50 100 300 500 1 3 5 10 30 50 100 300 500 3 3 3 3 Operating frequency (×10 operations) Operating frequency (×10 operations) Operating frequency (×10 operations) Operating frequency (×10 operations) ●Contact Reliability Test ●Must Operate and Must ●Distribution of Bounce (Contact Resistance) *1, *2 Release Time Distribution *1 Time *1 G6S-2F(G) G6S-2F(G) G6S-2F(G) 1,000 60 60 Sample: G6S-2F Sample: G6S-2F Sample: G6S-2F NO contact Must operate time Operating bounce time Number of Relays: 10 pcs Number of Relays: 50 pcs Number of Relays: Test conditions: 10 μA NC contact 500 Must release time 50 pcs Release bounce time resistive load at 10 m VDC with an operation rate of 50% 300 Switching frequency: 7,200 operations/h 40 40 100 max. max. 50 20 20 min. G min. 30 6 S 10 10 30 50 100 300 500 1,000 10,000 50,000 0 0.5 1 1.5 2 2.5 3 0 0.5 1 1.5 2 2.5 3 3 Operating frequency (×10 operations) Time (ms) Time (ms) ●Mutual Magnetic ●External Magnetic Interference Interference G6S-2F(G) G6S-2F(G) (Average value) (Average value) (Average value) Must operate voltage +30 +30 +30 Must release voltage SN SN SN SN SN SN Initial stage Test +20 +20 +20 2.22 mm +30 +20 +10 +10 +10 +10 0 −10 Sample 0 0 0 −20 Average value Not −30 energized Initial stage Test −10 −10 −10 +30 +20 +10 −20 −20 −20 Sample 0 Must operate voltage Must operate voltage Must operate voltage Sample: G6S-2F Sample: G6S-2F Sample: G6S-2F Must release voltage Must release voltage Must release voltage −10 Number of Relays:10 pcs Number of Relays:10 pcs Number of Relays:10 pcs −30 −30 −30 Energized −20 −1,200 −800 −400 0 400 800 1,200 −1,200 −800 −400 0 400 800 1,200 −1,200 −800 −400 0 400 800 1,200 Average value −30 External magnetic field (A/m) External magnetic field (A/m) External magnetic field (A/m) ●High-frequency ●High-frequency ●High-frequency ●Mutual Magnetic Characteristics Characteristics Characteristics Interference (Isolation) *1, *2 (Insertion Loss) *1, *3 (Return Loss, V.SWR) *1, *3 G6S-2F(G) G6S-2F(G) (Average value (initial)) G6S-2F(G) (Average value (initial)) G6S-2F(G) (Average value (initial)) Must operate voltage 0 0 0 2.5 Sample: G6S-2F Sample: G6S-2F Must release voltage Number of Relays: 10 pcs Number of Relays: 10 pcs Initial stage Test 4.64 mm 5 +30 0.4 2.0 +20 20 +10 10 0 0.8 1.5 −10 V.SWR 40 15 −20 Average value Sample Not −30 1.2 1.0 energized Initial stage Test 20 +30 60 +20 1.6 Return loss 0.5 +10 25 Sample 0 Sample: G6S-2F Number of Relays: 10 pcs −10 80 2.0 30 0 10 30 50 100 300 500 1,000 5,000 10 30 50 100 300 500 1,000 5,000 10 30 50 100 300 500 1,000 5,000 −20 Average value Energized −30 Frequency (MHz) Frequency (MHz) Frequency (MHz) *1. The tests were conducted at an ambient temperature of 23°C. *2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use. *3. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics, including durability, in the actual machine before use. 4 Contact resistance (m ) Ω On the basis of rated voltage (%) Change rate on the Change rate on the Change rate on the Change rate on the basis of initial value (%) basis of initial value (%) basis of initial value (%) basis of initial value (%) Contact resistance (mΩ) Rate of variability (%) Isolation (dB) Rate of variability (%) Insertion loss (dB) Number of contacts On the basis of rated voltage (%) Rate of variability (%) Contact resistance (m ) Ω Number of contacts Return loss (dB) V.SWR G6S Surface-mounting Relay ■Dimensions Mounting Dimensions (Top View) Terminal Arrangement/ Single-side Stable Tolerance: ±0.1 mm Internal Connections G6S-2F (Top View) 2.54 G6S-2F-Y ±0.2 ±0.2 14.8 7.3 5.08 2.54 Orientation mark 12 10 9 8 9.2±0.2 2.2 0.65 8 0.25 +0.5 1 3 4 5 0.5 9.2 −0.3 2.54 5.08 1 Note: Check carefully the coil 2.54 Note 1. Each value has a tolerance of ±0.3 mm. polarity of the Relay. Note 2.The coplanarity of the terminals is 0.1 mm max. Mounting Dimensions (Top View) Terminal Arrangement/ G6S-2G Tolerance: ±0.1 mm Internal Connections G6S-2G-Y (Top View) ±0.2 ±0.2 14.8 7.3 2.54 Orientation mark 5.08 2.54 12 10 9 8 9.2±0.2 0.65 6.1 2.2 0.25 0.5 1 3 4 5 +0.3 4.9 5.08 2.54 −0.5 1 Note: Check carefully the coil 2.54 Note 1. Each value has a tolerance of ±0.3 mm. polarity of the Relay. Note 2.The coplanarity of the terminals is 0.1 mm max. PCB Mounting Holes Terminal Arrangement/ G6S-2 G (Bottom View) Internal Connections 6 G6S-2-Y (Bottom View) 2.54 Eight, 1-dia. holes S ±0.2 ±0.2 14.8 7.3 Orientation mark 2.54 1 3 4 5 ±0.2 9.2 0.65 ±0.1 5.08 2.95 12 10 9 8 0.5 0.25 (1.11) Note: Check carefully the coil 5.08 5.08 5.08 2.54 polarity of the Relay. (1.05) 2.54 2.54 2.54 Note: Each value has a tolerance of ±0.3 mm. Mounting Dimensions (Top View) Terminal Arrangement/ Single-winding Latching Tolerance: ±0.1 mm Internal Connections G6SU-2F (Top View) 14.80.2 7.30.2 2.54 G6SU-2F-Y Orientation mark 5.08 2.54 12 10 9 8 0.2 9.2 0.65 2.2 8 S R 0.25 0.5 0.5 9.2 1 3 4 5 0.3 5.08 2.54 1 Note: Check carefully the coil 2.54 Note 1. Each value has a tolerance of ±0.3 mm. polarity of the Relay. Note 2.The coplanarity of the terminals is 0.1 mm max. Mounting Dimensions (Top View) Terminal Arrangement/ G6SU-2G Tolerance: ±0.1 mm Internal Connections G6SU-2G-Y (Top View) ±0.2 ±0.2 14.8 7.3 2.54 Orientation mark 5.08 2.54 12 10 9 8 ±0.2 9.2 6.1 0.65 2.2 S R 0.25 0.5 1 3 4 5 1 +0.3 4.9 5.08 2.54 −0.5 Note: Check carefully the coil 2.54 Note 1. Each value has a tolerance of ±0.3 mm. polarity of the Relay. Note 2.The coplanarity of the terminals is 0.1 mm max. PCB Mounting Holes Terminal Arrangement/ G6SU-2 (Bottom View) Internal Connections G6SU-2-Y 2.54 Eight, 1-dia. holes (Bottom View) ±0.2 ±0.2 14.8 7.3 Orientation mark 2.54 1 3 4 5 ±0.2 9.2 0.65 ±0.1 5.08 S R 2.95 12 10 9 8 0.5 0.25 (1.11) Note: Check carefully the coil 5.08 5.08 5.08 2.54 (1.05) 2.54 polarity of the Relay. 2.54 2.54 Note: Each value has a tolerance of ±0.3 mm. 5 G6S Surface-mounting Relay Mounting Dimensions (Top View) Terminal Arrangement/ Double-winding Latching Tolerance: ±0.1 mm Internal Connections G6SK-2F (Top View) ±0.2 ±0.2 14.8 7.3 2.54 2.54 Orientation mark 5.08 2.54 12 10 9 8 7 9.2±0.2 0.65 S R 2.2 8 0.25 +0.5 0.5 9.2 1 3 4 5 6 −0.3 2.54 5.08 Note: Check carefully the coil 2.54 2.54 Note 1. Each value has a tolerance of ±0.3 mm. 1 polarity of the Relay. Note 2.The coplanarity of the terminals is 0.1 mm max. Mounting Dimensions (Top View) Terminal Arrangement/ G6SK-2G Tolerance: ±0.1 mm Internal Connections (Top View) ±0.2 ±0.2 14.8 7.3 2.54 2.54 Orientation mark 5.08 2.54 12 10 9 8 7 ±0.2 9.2 0.65 6.1 S R 2.2 0.25 0.25 1 3 4 5 6 0.5 1 +0.3 4.9 Note: Check carefully the coil 5.08 2.54 −0.5 2.54 2.54 Note 1. Each value has a tolerance of ±0.3 mm. polarity of the Relay. Note 2.The coplanarity of the terminals is 0.1 mm max. PCB Mounting Holes Terminal Arrangement/ G6SK-2 (Bottom View) Internal Connections G 2.54 Ten, 1-dia. holes (Bottom View) 14.8±0.2 7.3±0.2 6 Orientation mark S 2.54 1 3 4 5 6 9.2±0.2 0.65 5.08±0.1 S R (1.11) 2.95 12 10 9 8 7 0.5 0.25 Note: Check carefully the coil 5.08 5.08 2.54 5.08 (1.05) 2.54 polarity of the Relay. 2.54 2.54 2.54 2.54 Note: Each value has a tolerance of ±0.3 mm. 6 G6S Surface-mounting Relay ■Tube Packing and Tape Packing Surface mounting terminal (SMT) standard models are shipped in moisture-proof package, and PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package. Please refer to "Correct Use" for handling after opening moisture-proof packaging for Surface mounting terminal (SMT) models. (1) Tube Packing 2. Reel Dimensions • Relays in tube packing are arranged so that the orientation ±0.5 25.5 ±0.3 2 ±1.0 29.5 mark of each Relay in on the left side. ±0.2 ±0.5 13 21 Be sure not to make mistakes in Relay orientation when mounting the Relay to the PCB. Stopper Orientation of Relays Stopper (gray) (green) 80 330 R1 Tube length: 772 mm (stopper not included) No. of Relays per tube: 50 pcs 3. Carrie Tape Dimensions (2) Tape Packing (Surface Mounting Terminal Models) G6S-2F(-Y), G6SU-2F, G6SK-2F • When ordering Relays in tape packing, add the prefix “-TR” to ±0.1 9.7 ±0.1 +0.1 4 1.5 −0 the model number, otherwise the Relays in tube packing will 1.75±0.1 ±0.1 ±0.05 2 0.4 be provided. Relays per Reel: 400 pcs 11.5±0.1 G Minimum packing unit: 2 reels (800 pcs) 24±0.3 6 15.3 1. Direction of Relay Insertion S 16±0.1 Orientation mark Top tape 9.7 (cover tape) Pulling direction G6S-2G(-Y), G6SU-2G, G6SK-2G ±0.1 9.7 ±0.1 +0.1 4 1.5 −0 ±0.1 1.75 Carrier tape ±0.1 ±0.05 2 0.4 Embossed tape 11.5±0.1 ±0.3 24 15.3 16±0.1 7.8 7 G6S Surface-mounting Relay ■Recommended Soldering Method (1) IRS Method (Mounting Solder: Lead) • The thickness of cream solder to be applied should be within a range between 150 and 200 µm on OMRON’s recommended PCB pattern. • In order to perform correct soldering, it is recommended that Soldering the correct soldering conditions be maintained as shown 220 to 240 below on the left side. 180 to 200 Correct Soldering Incorrect Soldering Relay Terminal Preheating 150 Land Heel fillet PCB is formed Solder Insufficient amount Excessive amount 90 to 120 20 to 30 of solder of solder Time (s) (The temperature profile indicates the temperature on the circuit board Visually check that the Relay is properly soldered. surface.) (2) IRS Method (Mounting Solder: Lead-free) Uppwe surface of case (peak): 255°C max. G Soldering 250 max. 6 230 S 180 Preheating 150 Relay terminal section 120 max. 30 max. Time (s) (The temperature profile indicates the temperature on the PCB.) ■Approved Standards ■Precautions • Please refer to “PCB Relays Common Precautions” for correct use. UL recognized: (File No. E41515) CSA certified: (File No. LR31928) Correct Use Number of test • Long-term Continuously ON Contacts Contact form Coil ratings Contact ratings operations • Using the Relay in a circuit where the Relay will be ON 3 A, 30 VDC at 40°C continuously for long periods (without switching) can lead to DPDT (2c) 3 to 24 VDC 0.3 A, 110 VDC at 40°C 6,000 unstable contacts because the heat generated by the coil itself 0.5 A, 125 VAC at 40°C will affect the insulation, causing a film to develop on the BSI (EN62368-1) (File No.VC657351) (-Y type) contact surfaces. We recommend using a latching relay (magnetic-holding relay) in this kind of circuit. If a single-side Contact form Isolation category Voltage stable model must be used in this kind of circuit, we DPDT (2c) Supplementary Insulation 250 VAC recommend using a fail-safe circuit design that provides protection against contact failure or coil burnout. • Relay Handling • Use the Relay as soon as possible after opening the moistureproof package. (As a guideline, use the Relay within one week at 30°C or less and 60% RH or less.) If the Relay is left for a long time after opening the moisture-proof package, the appearance may suffer and seal failure may occur after the solder mounting process. To store the Relay after opening the moisture-proof package, place it into the original package and sealed the package with adhesive tape. • When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 40°C. Do not put the Relay in a cold cleaning bath immediately after soldering. • Claw Securing Force During Automatic Mounting 8 Temperature (°C) Temperature (°C) G6S Surface-mounting Relay • During automatic insertion of Relays, be sure to set the securing force of each claw to the following so that the Relay’s characteristics will be maintained. C B A Dimension A: 1.96 N max. Dimension B: 4.90 N max. Dimension C: 1.96 N max. G 6 S Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K093-E1-13 0118(0207)(O) 9

Frequently asked questions

How does Electronics Finder differ from its competitors?

chervon down
Electronics Finder' parent company, GID Industrial, specializes in procuring industrial parts. We know where to find the rare and obsolete equipment that our customers need in order to get back to business. We stand apart from our competition through our commitment to quality, and look forward to the opportunity to show you how.

Is there a warranty for the G6SU-2GDC12?

chervon down
The warranty we offer will be based on what we negotiate with our suppliers. Sometimes, a part will be sold as-is and without a warranty. We usually offer a one-year warranty for single board computers in particular because they are our specialty.

Which carrier will Electronics Finder use to ship my parts?

chervon down
We use FedEx, UPS, DHL, and USPS. We have accounts with each of them and generally ship using one of those, but we can also ship using your account if you would prefer. We are able to ship with other carriers if you would find it more convenient.

Can I buy parts from Electronics Finder if I am outside the USA?

chervon down
Electronics Finder will definitely serve you. We work with international clients all the time, which means we are regularly shipping goods all across the globe.

Which payment methods does Electronics Finder accept?

chervon down
Visa, MasterCard, Discover, and American Express are all accepted by Electronics Finder. We will also accept payment made with wire transfer or PayPal. Checks will only be accepted from customers in the USA. Terms may be offered (upon approval) for larger orders.

Why buy from GID?

quality

Quality

We are industry veterans who take pride in our work

protection

Protection

Avoid the dangers of risky trading in the gray market

access

Access

Our network of suppliers is ready and at your disposal

savings

Savings

Maintain legacy systems to prevent costly downtime

speed

Speed

Time is of the essence, and we are respectful of yours

What they say about us

FANTASTIC RESOURCE

star star star star star

One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!

Bucher Emhart Glass

EXCELLENT SERVICE

star star star star star

With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.

Fuji

HARD TO FIND A BETTER PROVIDER

star star star star star

Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.

Applied Materials

CONSISTENTLY DELIVERS QUALITY SOLUTIONS

star star star star star

Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.

Nidec Vamco

TERRIFIC RESOURCE

star star star star star

This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.

Trican Well Service

GO TO SOURCE

star star star star star

When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.

ConAgra Foods

Related Products

product

Signal Relay 12VDC 1A SPDT(12.5x7.5x10)mm THT G5V-1-2DC12

product

Signal Relay 24VDC 1A SPDT(12.5x7.5x10)mm THT G5V-1-2DC24

product

Signal Relay 5VDC 1A SPDT(12.5x7.5x10)mm THT G5V-1-2DC5

product

Signal Relay 6VDC 1A SPDT(12.5x7.5x10)mm THT G5V-1-2DC6

product

Signal Relay 9VDC 1A SPDT(12.5x7.5x10)mm THT G5V-1-2DC9