POWER PARTNERS PDAM240-12C-H
Specifications
Manufacturer
Power Partners
Manufacturers Part #
PDAM240-12C-H
Industry Aliases
PDAM240-12C-H
Series
PDAM240
Factory Pack Quantity
1
Application
General Purpose
Compliance
BF Compliant
Connection Type
Molex/JST
Cooling Method
Air-Cooled
Dimensions
4.10 x 2.44 x 1.95"
Efficiency
92.5%
Environmental Conditions
General Purpose
Industry
Industrial, Medical
Input Type
AC - Class I & II
Input Voltage Nominal
100-240 VAC
Isolation
4000 VAC
Mechanical Style
Open / Enclosed Frame
Mounting
Chassis Mount
Number of Outputs
1
Operating Temperature
-30 to +70°C (see derating)
Output Amps 1
20.0 A
Output Voltage V1 Nominal
12 VDC
Package Type
Enclosed with Fan
PFC
Yes
Power
240 W
Protection Level
2xMOPP
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
PDAM240 Series 240W Power Supply • Open Frame or Enclosed Versions Available • UL / IEC / EN 60601 3.1 Edition & UL / IEC / EN 60950 AM2 Safety Approvals • 4000VAC Input to Output Isolation (2x MOPP) • Class I and Class II Input Configurations • Suitable for BF Application with appropriate system consideration • High Efficiency up to 93.5% • <0.5 W No Load Input Power Input Environmental & Operating Operating Temperature: -30ºC to +70ºC (with derating) Input Voltage: 90-264 VAC or 120-370 VDC Storage Temperature: -35ºC to +85ºC Input Frequency: 47-63 Hz Humidity: 95% RH Input Current (RMS): <3.0A @ 115 VAC; <1.5A @ 230 VAC Operating Altitude <5000m for medical use Power Factor: >0.9 @ full load (230 VAC) MTBF: >160K hours per MIL-HDBK-217F at full Inrush Current (<2ms): <45A @ 115 VAC; <90A @ 230 VAC load and 25ºC ambient Earth Leakage Current: <100 uA max. Compliance Safety Approvals: nd USA/Canada: UL60601-1 3.1 Ed, UL/cUL60950-1 2 Output Amdt. Europe: IEC/EN60601-1 3.1 Ed, TUV EN60950-1 Total Output: 240W max. See table for details. nd CB Report 2 Amdt. Output Voltage: See table. Isoluation: 4000VAC input to output 2x MOPP Hold Up Time: 10ms typical at 115VAC nominal line. (Note 3) 1500VAC input to ground 1x MOPP 1500VAC output to ground 1x MOPP Efficiency: Up to 93.5%. See table for details. EMC (IEC50501-1-2:2014): FCC Class B Radiated & Conducted EN55011/55022 Class B Radiated & Minimum Load: 0% Conducted Harmonic Currents: IEC 61000-3-2 Voltage Flicker: IEC 61000-3-3 Electrostatic Discharge: IEC 61000-4-2: 15kV air, 8kV contact Radiated Immunity: IEC 61000-4-3: 10V/m EFT/Burst: IEC 61000-4-4: +/-2kV Protection Surge Immunity: IEC 61000-4-5: 2005 1kV diff, 2kV com Conducted Immunity: IEC 61000-4-6: 10Vms Overvoltage: 110-132%, Auto Recovery IEC 61000-4-8: 30A/m Magnetic Field: IEC 61000-4-11: 30% reduction for Dips / Interruptions: Overcurrent: 105-170%, Auto Recovery 500ms, 100% reduction for 10 ms. Short Circuit: Auto Recovery General Dimensions: 2.05”W x 4.10”L x 1.087”H Weight: 220g Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM240: NOV 14, 2017 Medical AC/DC Power PDAM240 Series 240W Power Supply Models and Ratings (Note 4) Note: 1. All models are available in an enclosed version (e.g. PDAM240-12A would be PDAM240-12C) 2. We strongly recommend to conduct Hi-Pot test with DC voltage. If wanting to test with AC voltage, disconnect all Y-Capacitors within power supply. 3. Hold-up Time measured at 90% Vout 4. Measured at 20MHz bandwidth with a 47uF electrolytic capacitor and 0.1uF ceramic capacitor in parallel at the output connector. 5. Please secure the PSU to your casing by using the four screw holes in the corners for Class I and Class II equipment. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other than the ones listed on this datasheet. Block Diagram Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM240: NOV 14, 2017 Medical AC/DC Power PDAM240 Series 240W Power Supply Mechanical Outline (Open Frame Standard Terminal Block) Signal Signal Header Version Signal Signal Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM240: NOV 14, 2017 Medical AC/DC Power PDAM240 Series 240W Power Supply Mechanical Outline (Enclosed Frame Standard Terminal Block) Signal Signal Header Version Signal Signal Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM240: NOV 14, 2017 Medical AC/DC Power PDAM240 Series 240W Power Supply Power Derating Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749 Your Partners in Power……... Tel: (978)567-9600 | Fax: (978)567-9601 Specifications subject to change. Website: www.powerpartners-inc.com PDAM240: NOV 14, 2017 Medical AC/DC Power
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the PDAM240-12C-H?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods