Details

Part Number PM150-14A
Manufacturer PROTEK POWER
Category Circuit Protection »  AC-DC Power Supply
Price Request Quote
Lead Time Request Quote

Description

150 W, Single Output, 24 V@6.3 A Medical Open Frame AC-DC Power Supply

Request a Quote

* indicates a required field.
Your Contact Information
Your Company/Organization
Your Requirement
By sending us your information, you are affirming your agreement with our Privacy Policy.
You will not receive unsolicited communications.

Our Process

Our Process: Preparation
Preparation

Once you accept your quote and confirm your order, we prepare by retrieving related parts and components from our inventory. Anything we do not currently have in stock is sourced.

Our Process: Receiving
Receiving

Upon receipt, all parts are visually inspected for damage and then photographed to document their condition. Parts acquired from vendors must meet our quality standards.

Our Process: Initial Testing
Initial Testing

Industrial computer boards and other parts we are equipped to evaluate are tested to verify functionality and discover possible damage.

Our Process: Refurbishment
Refurbishment

Industrial computer boards have all components with low MTBF numbers (such as capacitors and connectors) replaced and are washed in our PCB cleaner to remove dust and grime.

Our Process: Repair
Repair

Industrial computer boards are fully diagnosed and repaired by our engineers. Logs of the problems encountered and solutions implemented are recorded.

Our Process: Final Testing
Final Testing

Industrial computer boards have all I/O connections rigorously tested to ensure that everything is working properly before the board is certified as ready to ship.

Our Process: Shipping
Shipping

After photos are taken to document the exterior condition of the part, it is packaged and sent to the customer. ESD-safe materials are used to protect sensitive equipment on its journey.

Who We Are

Electronics Finder is a website of GID Industrial, an ISO 9001:2015-certified company that has specialized in servicing industrial computer boards and providing other industrial products for sectors including manufacturing, defense, aerospace, entertainment, healthcare, and more by utilizing our combined skills and vast international network of trusted suppliers since our founding in 2015.

Do you need a PM150-14A? We can help you find it at a competitive price!

Specifications

Manufacturer Protek Power
Manufacturers Part # PM150-14A
Industry Aliases PM150-14A
Series PM150
Factory Pack Quantity 1
Application General Purpose
Compliance BF Compliant
Connection Type Molex/JST
Convection Rating 100 W
Cooling Method Air-Cooled, Convection
Dimensions 2.00 x 4.00 x 1.26"
Efficiency 89%
Environmental Conditions General Purpose
Industry Medical
Input Type AC
Isolation Class I, Class II
Mechanical Style Open / Enclosed Frame
Number of Outputs 1
Operating Temperature 0 to +70°C, derate linearly to 50% power from 50-70°C
Output Amps 1 6.3 A
Output Voltage V1 Nominal 24 V
Package Type Open Frame
Power 150 W
Protection Level 2xMOPP
Standard Packaging Size 2 x 4
Subcategory AC-DC Power Supply

Datasheet

Download "PM150.pdf" (368 KiB)

Extracted Text

PROTEK PM150 SERIES 150 Watt Open Frame Power Supply 100-150 WATT MEDICAL & ITE POWER SUPPLIES Measures: 2.00 x 4.00 x 1.26” DESCRIPTION PM150 SERIES The PM150 series of AC-DC switching power supplies in a package of 2 x 4 x 1.3 inches are capable of delivering RoHS 100-150 watts of continuous power at 7.5 CFM forced air cooling or 100 watts at convection cooling. The units are constructed on a printed circuit board. They are specially designed for medical applications, but not for life-supporting equipment. The units are certified also to IEC /EN /UL /CSA 60950-1 and suitable for data networking, computer and telecommunication applications. FEATURES  BF Class insulation  Operation up to 5000 meters SAFETY STANDARD APPROVAL  2 x 4 inch footprint with 1.3 inch low profile  100-240 VAC input with active PFC UL ES 60601-1, CSA C22.2 No. 60601-1  Less than 275 μA leakage current File No. E178020  Meet EN55011 /55022 and FCC Class B  Power Factor 0.98 typical  100% burn-in at full load TÜV EN 60601-1  Short -circuit protection  Power Fail Detect (PFD) signal (option)  Compliant with RoHS requirements UL 60950-1, CSA C22.2 No. 60950-1  High Efficiency 89% typical  No load power consumption less than 0.5W without PFD or 1W with PFD TÜV EN 60950-1 GENERAL SPECIFICATIONS INPUT SPECIFICATIONS Input voltage: 90-264 VAC Switching frequency: 133 KHz (typical) Input frequency: 47-63 Hz Efficiency: See rating chart. Input current: 1.7 A (rms) for 115 VAC Hold-up time: 10 ms minimum at 120 VAC 0.85 A (rms) for 230 VAC Line regulation: ±0.5% maximum at full load Earth leakage current: 275 μA max. @ 264 VAC, 63 Hz Inrush current: 55 A @ 115 VAC or 110 A @ 230 VAC, at 25℃ cold start Withstand voltage: 4000 VAC from input to output (2 MOPP) OUTPUT SPECIFICATIONS 1500 VAC from input to ground (1 MOPP) Output voltage/current: See rating chart. 1500 VAC from output to ground Total output power: See rating chart. MTBF: 250,000 hours at full load at 25℃ ambient, Ripple and noise: See rating chart. calculated per MIL-HDBK-217F Overvoltage protection: set at 112-140% of its nominal output EMC Performance voltage EN55011/EN55022: Class B conducted, class B radiated Overcurrent protection: Output protected to short circuit conditions FCC: Class B conducted, class B radiated Temperature coefficient: All outputs ±0.04% /℃ maximum VCCI: Class B conducted, class B radiated Transient response: Maximum excursion of 4% or better on all EN61000-3-2: Harmonic distortion, class A and D models, recovering to 1% of final value within 500 us after a 25% step load change EN61000-3-3: Line flicker Fan power: 12 V at 0.5 A maximum (isolated) EN61000-4-2: ESD, ±8 KV air and ±6 KV contact EN61000-4-3: Radiated immunity, 3 V/m EN61000-4-4: Fast transient/burst, ±2 KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com ENVIRONMENTAL SPECIFICATIONS EN61000-4-6: Conducted immunity, 3 Vrms Operating temperature: 0℃to +70℃ EN61000-4-8: Magnetic field immunity, 3 A/m Storage temperature: -40℃to +85℃ EN61000-4-11: Voltage dip immunity, 30% reduction for 500 Relative humidity: 5% to 95% non-condensing ms, 60% reduction for 100 ms, >95% Derating: Derate from 100% at +50℃linearly to 50% reduction for 10 ms at +70℃, applicable to convection and forced-air cooling conditions 9 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/protek-PM150-power-supply.html h t t p: / / pow e r. sa ge r. c om PROTEK PM150 SERIES 150 Watt Open Frame Power Supply UNIVERSAL INPUT PM150 MEDICAL & ITE SERIES Measures: 2.00 x 4.00 x 1.26” OUTPUT VOLTAGE/CURRENT RATING CHART Output Efficiency (typical) Max. Power Max. Power Max. Current (1) Max. Current Peak Ripple & at convection at 7.5 CFM at (3) (2) Model V1 Min. load convection at 7.5 CFM Current Tol. Noise Max. Power 115/230 Vac 115/230 Vac PM150-12A 12 V 0 A 8.35 A 12.50 A 14.0 A ±2% 120 mV 100 W /150 W 87 /89% 86 /88% 6.70 A PM150-13A 15 V 0 A 10.00 A 11.0 A ±2% 150 mV 100 W /150 W 87 /89% 86 /88% PM150-13-1A 18 V 0 A 5.56 A 8.34 A 9.2 A ±2% 180 mV 100 W /150 W 87 /89% 86 /88% PM150-14A 24 V 0 A 4.20 A 6.25 A 7.0 A ±2% 240 mV 87 /89% 86 /88% 100 W /150 W 3.34 A PM150-16A 30 V 0 A 5.00 A 5.6 A ±2% 300 mV 100 W /150 W 87 /89% 86 /88% 2.78 A PM150-17A 36 V 0 A 4.17 A 4.6 A ±2% 360 mV 100 W /150 W 87 /89% 86 /88% PM150-18A 48 V 0 A 2.10 A 3.13 A 3.5 A ±2% 480 mV 87 /89% 86 /88% 100 W /150 W NOTES: 1. Peak output current with 10% duty cycle maximum for less than 15 seconds, average power not to exceed maximum power rating. 2. The first value of max. power is at convection cooling. The second value is with 7.5 CFM forced air provided by user. 3. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector P1: JST header P/N V3P-VH-B, mating with JST housing P/N VHR-3N or equivalent. 4. Output connector P2: JST header P/N V8P-VH-B, mating with JST housing P/N VHR-8N or equivalent. 5. Connector P3: JST header B4B-PH-K-S (LF) (SN) , mating with JST housing PHR-4 or equivalent. 6. FAN connector P4: JST header B2B-PH-K-S (LF) (SN) , mating with JST housing PHR-2 or equivalent. 7. Ground tab is 0.25 [6.35] × 0.032 [0.8] fast-on connector. Weight: 200 grams (0.44 lbs.) approx. 10 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/protek-PM150-power-supply.html h t t p: / / pow e r. sa ge r. c om PROTEK PM150 SERIES 150 Watt Open Frame Power Supply UNIVERSAL INPUT PM150 MEDICAL & ITE SERIES Measures: 2.00 x 4.00 x 1.26” INTERFACE SIGNALS OUTPUT POWER DERATING CURVE PFD: TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1ms prior to V1 output dropping 5% below its nominal value. This signal also provides a minimum delay of 100 ms after V1 is within regulation. PIN CHART Connector P1 P2 PIN NO. 1 2 3 1 2 3 4 5 6 7 8 Polarity Neutral Void Live Common Return +V1 Connector P3 P4 PIN NO. 1 2 3 4 1 2 Fan Return Polarity Common Return PFD -Sense +Sense +12V Fan (Isolated) 11 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/protek-PM150-power-supply.html h t t p: / / pow e r. sa ge r. c om

Related Products

PROTEK POWER
AC/DC Power Supply Single-OUT 30V 6.7A 100W 20-Pin
PROTEK POWER
200 W, Single Output, 30 V@6.7 A Medical Enclosed with Fan AC-DC Power Supp...
PROTEK POWER
200 W, Double Output, 12 V@8.69999999999999 A | 24 V@4 A Medical Enclosed w...
PROTEK POWER
200 W, Triple Output, 5.1 V@30 A | 15 V@6 A | -12 V@4 A Medical Enclosed wi...
PROTEK POWER
200 W, Triple Output, 5.1 V@30 A | 12 V@8 A | 24 V@4 A Medical Enclosed wit...
PROTEK POWER
200 W, Quad Output, 5.1 V@30 A | 12 V@8 A | -12 V@4 A | 12 V@4 A Medical En...

Disclaimer

Any product names, logos, brands, and other trademarks or media featured or referred to on Electronics Finder are the property of their respective owners.

GID Industrial is not an authorized distributor, reseller, or representative for the products featured on this site, and is not affiliated with, sponsored by, or endorsed by any of the manufacturers or holders of the rights to the aforementioned products.

All information on this site is displayed strictly for identification purposes and does not indicate a relationship with or an approval from any third parties.

Electronics Finder is a GID Industrial website.
GID Industrial Logo
Copyright © 2024 GID Holdings LLC, All Rights Reserved.
Page generated in 0.593 seconds.