PROTEK POWER PM201-16C
Specifications
Manufacturer
Protek Power
Manufacturers Part #
PM201-16C
Industry Aliases
PM201-16C
Series
PM201
Factory Pack Quantity
1
Application
General Purpose
Connection Type
Terminal
Convection Rating
100 W
Cooling Method
Air-Cooled, Convection
Dimensions
7.00 x 4.00 x 1.50"
Efficiency
85%
Environmental Conditions
General Purpose
Industry
Medical
Input Type
AC
Isolation
Class I
Mechanical Style
Open / Enclosed Frame
Number of Outputs
1
Operating Temperature
0 to +70°C, derate linearly to 50% power from 50-70°C
Output Amps 1
6.7 A
Output Voltage V1 Nominal
30 V
Package Type
Enclosed with Fan
Power
200 W
Protection Level
2xMOPP
Subcategory
AC-DC Power Supply
Datasheet
Extracted Text
PROTEK PM201 SERIES 200 Watt Enclosed with Fan Power Supply 150-200 WATT MEDICAL & ITE POWER SUPPLIES Measures: 7.00 x 4.00 x 1.50” PM201 SERIES DESCRIPTION The PM201 series comprising single and multiple output models for 150 to 200 watts of continuous output power is specially 5R+6 designed for medical and ITE applications, not for life-support. They operate at 90 to 264 VAC input voltage without the need of a selector strap. All auxiliary outputs are with magnetic amplifier linear regulator to keep regulation. The units are constructed on a printed circuit board with a U-bracket for mechanical support and heat sinking. A cover and fan assembly can be added during manufacturing. FEATURES z Low safety ground leakage current z Meet EN55011, EN55022 and FCC Class B SAFETY STANDARD APPROVALS z Power Factor 0.98 typical UL ES 60601-1, CSA C22.2 No. 60601-1 z Short-circuit protection File No. E178020 z Power Fail Detect (PFD) signal UL 60950-1 z 100% burn-in at full rated load File No. E137410 z Optional cover and fan assembly z Remote inhibit - TTL high to disable output TÜV EN60601-1 z Compliant with RoHS requirements TÜV EN60950-1 INPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Input voltage: 90-264 VAC Operating temperature: 0к to +70к Input frequency: 47-63 Hz Storage temperature: -40к to +85к Input current: 3.20 A (rms) for 115 VAC Relative humidity: 5% to 95% non-condensing 1.60 A (rms) for 230 VAC Derating: Derate from 100% at +50к Earth leakage current: 220ʳȝA max. @ 264 VAC, 63 Hz linearly to 50% at +70к Cooling: 10.8 CFM forced air provided on “C” version; 25 CFM forced air to be provided OUTPUT SPECIFICATIONS for “B” version by user. Output voltage/current: See rating chart. Maximum output power: See rating chart. GENERAL SPECIFICATIONS Ripple and noise: 2% peak to peak maximum on 3.3 V & 5.1 V Switching frequency: 88-112 KHz and 1% peak to peak maximum on other Efficiency: 70% minimum on all models voltage outputs Hold-up time: 20 ms minimum at 110 VAC Overvoltage protection: Provided on output #1 only; set at 112-132% Line regulation: ±0.5% maximum at full load of its nominal output voltage Inrush current: 20 A @ 115 VAC or 40 A @ 230 VAC, at 25к Overcurrent protection: All outputs protected to short circuit cold start conditions Withstand voltage: 5600 VDC from input to output (2 MOPP) Temperature coefficient: All outputs ±0.04% /к maximum 2100 VDC from input to ground (1 MOPP) Transient response: Maximum excursion of 4% or better on all 700 VDC from output to ground models, recovering to 1% of final value (To verify AC strength, get correct test method within 500 us after a 25% step load change to avoid power supply damage.) MTBF: 350,000 hours at full load at 25к ambient, Fan power: 12 V at 200 mA maximum, except 24 V at calculated per MIL-HDBK-217F 200 mA maximum for PM201-25B and EMC Performance (EN60601-1-2) PM201-27B, and 5 V at 380 mA maximum EN55011/EN55022: Class B conducted, class B radiated for PM201-40-3B EN61000-3-2: Harmonic distortion, class A and D EN61000-3-3: Line flicker INTERFACE SIGNALS EN61000-4-2: ESD, ±8 KV air and ±6 KV contact PFD: TTL logic high for normal operation and TTL logic low upon EN61000-4-3: Radiated immunity, 3 V/m loss of input power. This signal appears at least 1ms prior to EN61000-4-4: Fast transient/burst, ±2 KV V1 output dropping 5% below its nominal value. This signal EN61000-4-5: also provides a minimum delay of 100 ms after V1 is within Surge, ±1 KV diff., ±2 KV com. regulation. EN61000-4-6: Conducted immunity, 3 Vrms EN61000-4-8: Magnetic field immunity, 3 A/m Voltage dip immunity, 30% reduction for Inhibit: Requires an external TTL high level signal to inhibit EN61000-4-11: 500 ms, 60% reduction for 100 ms, and outputs for standard models >95% reduction for 10 ms Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. 13 Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/protek-PM201-power-supply.html h t t p: / / pow e r. sa ge r. c om PROTEK PM201 SERIES 200 Watt Enclosed with Fan Power Supply UNIVERSAL INPUT PM201 MEDICAL & ITE SERIES Measures: 7.00 x 4.00 x 1.50” OUTPUT VOLTAGE/CURRENT RATING CHART (4) (2)(4) (3) Output #1 Output #2 Output #3 Output #4 Imax Max. Output (1) (4) Model V1 Imin. Imax. Tol. V2 Imin. Imax. Tol. V3 Imin. Imax. Tol. V4 Imin. . Tol. Power PM201-10B 5.1 V (N/A) (N/A) (N/A) 87.5 W /175 W 3.0 A 35.0 A ̈́2% (N/A) (N/A) (N/A) PM201-10-3B 3.3 V 3.0 A 46.0 A ̈́3% 75 W /150 W PM201-12B 12 V (N/A) (N/A) (N/A) 100 W /200 W 1.2 A 16.7 A ̈́2% (N/A) (N/A) (N/A) PM201-13B 15 V 1.0 A 13.4 A ̈́2% 100 W /200 W PM201-14B 24 V (N/A) (N/A) (N/A) 100 W /200 W 0.6 A 8.4 A ̈́2% PM201-16B 30 V 0.5 A 6.7 A ̈́2% (N/A) (N/A) (N/A) 100 W /200 W (N/A) (N/A) (N/A) PM201-18B 48 V 0.5 A 4.2 A ̈́2% 100 W /200 W PM201-23B +5.1 V 3.0 A 30.0 A ̈́2% +12 V 0 A 8 A ̈́4% (N/A) (N/A) 100 W /200 W (N/A) (N/A) PM201-24B +5.1 V 3.0 A 30.0 A ̈́2% +15 V 0 A 6 A ̈́4% 100 W /200 W PM201-25B +5.1 V 3.0 A 30.0 A ̈́2% +24 V 0 A 4 A ̈́4% (N/A) (N/A) 100 W /200 W (N/A) (N/A) PM201-27B +12 V 1.0 A 8.7 A ̈́2% +24 V 0 A 4 A ̈́4% 100 W /200 W PM201-30B +5.1 V 3.0 A 30.0 A ̈́2% +12 V 0 A 8 A ̈́4% -5 V 0 A 6 A ̈́4% (N/A) 100 W /200 W (N/A) PM201-31B +5.1 V 3.0 A 30.0 A ̈́2% +12 V 0 A 8 A ̈́4% -12 V 0 A 4 A ̈́4% 100 W /200 W PM201-32B +5.1 V 3.0 A 30.0 A ̈́2% +15 V 0 A 6 A ̈́4% -15 V 0 A 4 A ̈́4% (N/A) 100 W /200 W (N/A) PM201-33B +5.1 V 3.0 A 30.0 A ̈́2% +15 V 0 A 6 A ̈́4% -12 V 0 A 4 A ̈́4% 100 W /200 W PM201-36B +5.1 V 3.0 A 30.0 A ̈́2% +12 V 0 A 8 A ̈́4% 24 V 0 A 4 A ̈́4% (N/A) 100 W /200 W PM201-40B +5.1 V 3.0 A 30.0 A ̈́2% +12 V 0 A 8 A ̈́4% -12 V 0 A 4 A ̈́4% 5 V 0 A 6 A ̈́4% 100 W /200 W PM201-41B +5.1 V 3.0 A 30.0 A ̈́2% +15 V 0 A 6 A ̈́4% -15 V 0 A 4 A ̈́4% 24 V 0 A 4 A ̈́4% 100 W /200 W PM201-42B +5.1 V 3.0 A 30.0 A ̈́2% +12 V 0 A 8 A ̈́4% -12 V 0 A 4 A ̈́4% 12 V 0 A 4 A ̈́4% 100 W /200 W PM201-44B +5.1 V 3.0 A 30.0 A ̈́2% +12 V 0 A 8 A ̈́4% -15 V 0 A 4 A ̈́4% 15 V 0 A 4 A ̈́4% 100 W /200 W PM201-45B +5.1 V 3.0 A 30.0 A ̈́2% +12 V 0 A 8 A ̈́4% -12 V 0 A 4 A ̈́4% 24 V 0 A 4 A ̈́4% 100 W /200 W PM201-40-3B +3.3 V 3.0 A 30.0 A ̈́3% +5.1 V 0 A 8 A ̈́4% -12 V 0 A 4 A ̈́4% 12 V 0 A 4 A ̈́4% 87.5 W /175 W NOTES: OUTPUT POWER DERATING CURVE 1. Suffix “B” in model numbers denotes U-bracket form. Change “B” to “C” for enclosed form with cover and fan assembly, e.g. PM201-45C. 2. Peak output current is 12 A on +12 V, 9 A on +15 V and 6 A on +24 V. 3. Output #4 is floating. It can be connected externally for positive or negative output. 4. 200 watts for “C” version with a cover and fan assembly. 100 watts for “B” version without moving air (maximum current of output #1 & #2 derated to 50%), or 200 watts with 25 CFM forced air provided by user. 5. When the remote Sense facility is not used, +Sense must be connected to +V, and -Sense to return, on P2 connector. 6. All models may be operated at no-load. At no-load, output voltage tolerance increases to ̈́10%. 7. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10ʳȝF tantalum capacitor in parallel with a 0.1ʳȝF ceramic capacitor across the output. MECHANICAL SPECIFICATIONS Single Output Models U-bracket Form Enclosed Form 14 Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/protek-PM201-power-supply.html h t t p: / / pow e r. sa ge r. c om PROTEK PM201 SERIES 200 Watt Enclosed with Fan Power Supply UNIVERSAL INPUT PM201 MEDICAL & ITE SERIES Measures: 7.00 x 4.00 x 1.50” MECHANICAL SPECIFICATIONS Multiple Output Models U-bracket Form Enclosed Form NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector P1 is Dinkle DT-35-B01W-03. Output connector P2 is Dinkle DT-35-B01W-09. Screws are M3, nickel plated. 4. Connector P3 mates with Molex housing 22-01-1043 and Molex 40445 series crimp terminal. 5. Connectors P4 and P5 mate with Molex housing 22-01-1023 and Molex 40445 series crimp terminal. 6. P4 is for DC fan, 12 V/0.2 A rated, Pin 1 +V and Pin 2 -V; except 24 V/0.2 A rated for models PM201-25 and PM201-27, and 5 V/0.38 A rated for models PM201-40-3). 7. Weight: 820 grams (1.8 lbs.) approx. for U-bracket form, 960 grams (2.1 lbs.) approx. for enclosed form. 8. Maximum penetration depth of fixing screws is 4 mm from the outer surface of chassis. PIN CHART CONN P2 P3 P5 PIN 1 2 3 4 5 6 7 8 9 1 2 3 4 1 2 MODEL PM201-10B PM201-14B PM201-10-3B PM201-16B Com. Com. Com. Com. Fan Com. Com. Inhibit Inhibit -Sense +V1 +V1 +V1 +Sense PFD Ret. Ret. Ret. PM201-12B PM201-18B Ret. +V Ret. Ret. +V -V PM201-13B PM201-23B PM201-25B Com. Com. Com. Fan Com. Com. Inhibit Inhibit V1 V1 V2 N.C. N.C. N.C. PFD Ret. Ret. Ret. +V Ret. Ret. +V -V PM201-24B PM201-27B PM201-30B PM201-32B Fan Com. Com. Inhibit Inhibit Com. Com. Com. V1 V1 V2 V3 N.C. N.C. PFD Ret. Ret. Ret. PM201-31B PM201-33B +V Ret. Ret. +V -V PM201-36B Com. Com. Com. V3 Fan Com. Com. Inhibit Inhibit V1 V1 V2 N.C. +V3 PFD Ret. Ret. Ret. Return +V Ret. Ret. +V -V PM201-40B PM201-44B Com. Com. Com. V4 Fan Com. Com. Inhibit Inhibit PM201-41B PM201-45B V1 V1 V2 V3 +V4 PFD Ret. Ret. Ret. Return +V Ret. Ret. +V -V PM201-42B PM201-40-3B Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. 15 Click below for more details, to buy on-line or request volume pricing: (866) 588-1750 power@sager .com http://power.sager.com/protek-PM201-power-supply.html h t t p: / / pow e r. sa ge r. c om
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the PM201-16C?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods