Extracted Text
Product data sheet SR3XT61JD Characteristics discrete I/O extension module - 6 I O - 12 V DC - for Zelio Logic Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 80.00 USD Main Range of product Zelio Logic Product or component type Discrete I/O extension module Complementary Number or control scheme lines 120 with ladder programming Cycle time 6...90 ms Backup time 10 yearsat 77 °F (25 °C) Clock drift 12 min/yearat 32...131 °F (0...55 °C) Checks Program memory on each power up [Us] rated supply voltage 12 V DC Supply voltage limits 10.4...14.4 V Reverse polarity protection With Discrete input number 4 conforming to EN/IEC 61131-2 type 1 Discrete input type Resistive Discrete input voltage 12 V DC Discrete input current 4 mA Counting frequency 1 kHzfor discrete input Voltage state 1 guaranteed >= 7 Vfor IB...IG used as discrete input circuit >= 5.6 Vfor I1...IA and IH...IR discrete input circuit Voltage state 0 guaranteed <= 3 Vfor IB...IG used as discrete input circuit <= 2.4 Vfor I1...IA and IH...IR discrete input circuit Current state 1 guaranteed >= 2 mA for I1...IA and IH...IR discrete input circuit >= 0.5 mA for IB...IG used as discrete input circuit Current state 0 guaranteed <= 0.2 mA for IB...IG used as discrete input circuit <= 0.9 mA for I1...IA and IH...IR discrete input circuit Input compatibility 3-wire proximity sensors PNP (discrete input) Input impedance 14 kOhm (IB...IG used as discrete input circuit) 2.7 kOhm (I1...IA and IH...IR discrete input circuit) Number of outputs 2 relay output(s) Output voltage limits 24...250 V AC (relay output) 5...30 V DC (relay output) Contacts type and composition NO relay output Jun 24, 2018 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Output thermal current 8 A for all 2 outputs (relay output) Electrical durability 500000 cyclesat 230 V, 0.9 A (AC-15)for relay output conforming to EN/IEC 60947-5-1 500000 cyclesat 230 V, 1.5 A (AC-12)for relay output conforming to EN/IEC 60947-5-1 500000 cyclesat 24 V, 0.6 A (DC-13)for relay output conforming to EN/IEC 60947-5-1 500000 cyclesat 24 V, 1.5 A (DC-12)for relay output conforming to EN/IEC 60947-5-1 Switching capacity in mA >= 10 mAat 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie)for relay output 10 Hz (no load)for relay output Mechanical durability 10000000 cycles (relay output) [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Response time 10 ms (from state 0 to state 1) relay output 5 ms (from state 1 to state 0) relay output Connections - terminals Screw terminals, flexible cable with cable end 1 x 0.25...1 x 2.5 mm² / AWG 24...AWG 14 AWG Screw terminals, flexible cable with cable end 2 x 0.25...2 x 0.75 mm² / AWG 24...AWG 18 AWG Screw terminals, semi-solid cable 1 x 0.2...1 x 2.5 mm² / AWG 25...AWG 14 AWG Screw terminals, solid cable 1 x 0.2...1 x 2.5 mm² / AWG 25...AWG 14 AWG Screw terminals, solid cable 2 x 0.2...2 x 1.5 mm² / AWG 24...AWG 16 AWG Tightening torque 4.42 lbf.in (0.5 N.m) Overvoltage category III conforming to EN/IEC 60664-1 Product weight 0.28 lb(US) (0.125 kg) Environment Product certifications C-Tick UL GL CSA GOST Standards EN/IEC 61000-4-6 level 3 EN/IEC 61000-4-12 EN/IEC 61000-4-11 EN/IEC 61000-4-4 level 3 EN/IEC 61000-4-3 EN/IEC 60068-2-6 Fc EN/IEC 60068-2-27 Ea EN/IEC 61000-4-2 level 3 EN/IEC 61000-4-5 IP degree of protection IP20 (terminal block) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529 Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2 EMC directive conforming to EN/IEC 61000-6-3 EMC directive conforming to EN/IEC 61000-6-4 EMC directive conforming to EN/IEC 61131-2 zone B Low voltage directive conforming to EN/IEC 61131-2 Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -4...104 °F (-20...40 °C) in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 -4...131 °F (-20...55 °C) conforming to IEC 60068-2-1 and IEC 60068-2-2 Ambient air temperature for storage -40...158 °F (-40...70 °C) Operating altitude 6561.68 ft (2000 m) Altitude transport <= 10000 ft (3048 m) Relative humidity 95 % without condensation or dripping water Ordering and shipping details Category 22378 - SR2,3 ZELIO 2 RELAYS Discount Schedule I GTIN 00785901466710 Nbr. of units in pkg. 1 Package weight(Lbs) 0.25 Returnability N Country of origin FR 2 Contractual warranty Warranty period 18 months 3 Product data sheet SR3XT61JD Dimensions Drawings I/O Extension Modules Mounting on 35 mm/1.38 in. DIN Rail Screw Fixing (Retractable Lugs) SR3 a (mm/in.) G (mm/in.) XT61•• 35 / 1.38 25 / 0.98 XT101•• 72 / 2.83 60 / 2.36 XT141•• 72 / 2.83 60 / 2.36 4 Product data sheet SR3XT61JD Connections and Schema Connection of Smart Relays on DC Supply, with Discrete I/O Extension Modules SR3B•••JD + SR3XT•••JD, SR3B•••BD + SR3XT•••BD (1) 1 A quick-blow fuse or circuit-breaker. (2) Ca: Analog sensor / Ta: Analog transmitter. (3) Recommended values: 2.2 kΩ / 0.5 W (10 kΩ max.) (4) Screened cables, maximum length 10 m / 32.80 feet. NOTE: QF and QG : 5 A for SR3XT141•• 5 Product data sheet SR3XT61JD Performance Curves Compact and Modular Smart Relays Electrical Durability of Relay Outputs (in millions of operating cycles, conforming to IEC/EN 60947-5-1) DC-12 (1) X: Current (A) Y: Millions of operating cycles (1) DC-12: control of resistive loads and of solid state loads isolated by opto-coupler, L/R ≤ 1 ms. DC-13 (1) X: Current (A) Y: Millions of operating cycles (1) DC-13: switching electromagnets, L/R ≤ 2 x (Ue x Ie) in ms, Ue: rated operational voltage, Ie: rated operational current (with a protection diode on the load, DC-12 curves must be used with a coefficient of 0.9 applied to the number in millions of operating cycles). 6
Frequently asked questions
How does Electronics Finder differ from its competitors?

Is there a warranty for the SR3XT61JD?

Which carrier will Electronics Finder use to ship my parts?

Can I buy parts from Electronics Finder if I am outside the USA?

Which payment methods does Electronics Finder accept?

Why buy from GID?

Quality
We are industry veterans who take pride in our work

Protection
Avoid the dangers of risky trading in the gray market

Access
Our network of suppliers is ready and at your disposal

Savings
Maintain legacy systems to prevent costly downtime

Speed
Time is of the essence, and we are respectful of yours
What they say about us
FANTASTIC RESOURCE
One of our top priorities is maintaining our business with precision, and we are constantly looking for affiliates that can help us achieve our goal. With the aid of GID Industrial, our obsolete product management has never been more efficient. They have been a great resource to our company, and have quickly become a go-to supplier on our list!
Bucher Emhart Glass
EXCELLENT SERVICE
With our strict fundamentals and high expectations, we were surprised when we came across GID Industrial and their competitive pricing. When we approached them with our issue, they were incredibly confident in being able to provide us with a seamless solution at the best price for us. GID Industrial quickly understood our needs and provided us with excellent service, as well as fully tested product to ensure what we received would be the right fit for our company.
Fuji
HARD TO FIND A BETTER PROVIDER
Our company provides services to aid in the manufacture of technological products, such as semiconductors and flat panel displays, and often searching for distributors of obsolete product we require can waste time and money. Finding GID Industrial proved to be a great asset to our company, with cost effective solutions and superior knowledge on all of their materials, it’d be hard to find a better provider of obsolete or hard to find products.
Applied Materials
CONSISTENTLY DELIVERS QUALITY SOLUTIONS
Over the years, the equipment used in our company becomes discontinued, but they’re still of great use to us and our customers. Once these products are no longer available through the manufacturer, finding a reliable, quick supplier is a necessity, and luckily for us, GID Industrial has provided the most trustworthy, quality solutions to our obsolete component needs.
Nidec Vamco
TERRIFIC RESOURCE
This company has been a terrific help to us (I work for Trican Well Service) in sourcing the Micron Ram Memory we needed for our Siemens computers. Great service! And great pricing! I know when the product is shipping and when it will arrive, all the way through the ordering process.
Trican Well Service
GO TO SOURCE
When I can't find an obsolete part, I first call GID and they'll come up with my parts every time. Great customer service and follow up as well. Scott emails me from time to time to touch base and see if we're having trouble finding something.....which is often with our 25 yr old equipment.
ConAgra Foods